Laboratory Glassware - Thermo Fisher Scientific
Transcription
Laboratory Glassware - Thermo Fisher Scientific
Choice & Convenience Laboratory Glassware Containerware • General Glassware Volumetric Glassware • Interchangeable Test, Culture & Specialty Tubes A World of Choice for Glassware Glassware is one of the staple products used in every laboratory and in this new glassware catalogue, Thermo Fisher Scientific offers you a range and choice of products which will suit every budget. The catalogue showcases a host of leading glassware brands, offering you both choice and convenience when selecting glassware for your laboratory. Quality and precision are the hallmarks of the glassware range available from Thermo Fisher, so irrespective of the brand you select you can be confident you will receive quality products. Readily available stock is an important factor when ordering glassware items. To assist you in this process, the catalogue denotes those items which are generally available from stock. The availability of appropriate certification is increasingly becoming an important factor, particularly when buying volumetric glassware. Recognising this need, the catalogue features products which again provide you with several options relating to glassware calibration and certification. While the catalogue is intended to showcase the main glassware products which are readily available, it is not all encompassing. If you are unable to locate an item you require, please contact your local Account Manager or Customer Service Representative and we will endeavour to source the product on your behalf. Finally, we trust you will find the catalogue beneficial and would encourage you to take advantage of the extensive knowledge and expertise Thermo Fisher have available to assist you in sourcing all your glassware needs. Volumetric Glassware pg.05 Test, Culture & Specialty Tubes General Glassware pg.21 Interchangeable Glassware pg.57 pg.67 Please also see our Technical Information section on page 87. Section >> Sub-Section Containerware pg 33 Related Products pg.83 Our Partnership Suppliers At Thermo Fisher Scientific, we continuously strive to bring our customers the best quality and innovative products and solutions. We achieve this through forming partnerships with supplier partners who specialise in market leading brands. Our success is attributed to the significant support from our suppliers and it is through these relationships that we relentlessly strive to extract value for our customers. Beakers06 Heavy Duty Beakers 08 Philips Beakers 09 Media Bottles 10 Boston Bottles 12 Erlenmeyer Flasks 14 Starter Packs 17 Plastic Coated Glassware 18 containerware Containerware Containerware Beakers Synonymous with quality and affordability, the range of LabServ glassware offers durability at competitive prices. Buy quality, reusable glass beakers at disposable prices. Use LabServ borosilicate glass beakers for routine measurement, mixing and gentle heating. Chemically resistant to most solvents, acids and bases. Laboratory Glassware Catalogue 2012/13 LabServ Low Form Beaker, Griffin, Borosilicate glass, Double Scale 6 Item Code Capacity Graduations Range (mL) Graduations Interval (mL) OD x Height Pack Size Unit LBS20201-50 50mL 10-40 5 42x60mm Each Pack of 12/Case of 192 LBS20201-100 100mL 20-80 10 50x70mm Each Pack of 12/Case of 192 LBS20201-150 150mL 20-140 10 60x80mm Each Pack of 12/Case of 192 LBS20201-200 * 200mL 25-175 10 66x90mm Each Pack of 12/Case of 144 LBS20201-250 250mL 25-200 25 70x95mm Each Pack of 12/Case of 144 LBS20201-300 * 300mL 25-250 25 74x105mm Each Pack of 12/Case of 96 LBS20201-400 400mL 50-350 25 80x110mm Each Pack of 12/Case of 72 LBS20201-500 500mL 50-400 25 85x120mm Each Pack of 6/Case of 72 LBS20201-600 600mL 100-500 50 90x125mm Each Pack of 6/Case of 48 LBS20201-800 800mL 100-750 50 100x135mm Each Pack of 6/Case of 36 LBS20201-1L 1,000mL 100-900 50 105x145mm Each Pack of 6/Case of 24 LBS20201-2L 2,000mL 200-1800 100 130x185mm Each Pack of 4/Case of 16 LBS20201-3L 3,000mL 300-2800 100 150x210mm Each Case of 8 LBS20201-4L * 4,000mL 500-3500 500 161x253mm Each Each LBS20201-5L 5,000mL 500-4500 500 170x270mm Each Case of 6 * denotes products not stocked Item Code Capacity Graduations Range (mL) Graduations Interval (mL) OD x Height Pack Size Unit LBS20202-50 50mL 10-40 10 38x70mm Each Pack of 24/Case of 192 LBS20202-100 100mL 20-80 10 48x80mm Each Pack of 24/Case of 192 LBS20202-150 150mL 20-140 20 54x95mm Each Pack of 12/Case of 192 LBS20202-250 250mL 25-200 25 60x120mm Each Pack of 12/Case of 72 LBS20202-300 * 300mL 50-250 25 64x125mm Each Case of 72 LBS20202-400 400mL 50-350 25 70x130mm Each Pack of 12/Case of 72 LBS20202-500 * 500mL 100-400 50 75x140mm Each Case of 48 LBS20202-600 600mL 100-500 50 80x150mm Each Pack of 6/Case of 48 LBS20202-800 800mL 100-750 50 90x175mm Each Case of 48 LBS20202-1L 1,000mL 100-900 50 95x180mm Each Pack of 6/Case of 36 Containerware >> Beakers LabServ Tall Form Beaker, Berzelius, Borosilicate glass, Double Scale Kimble Brand KIMAX beakers provide strength and durability from top to bottom. Uniform sidewall and bottom thickness, especially in the critical radius point of the heel area, provides excellent mechanical and thermal shock resistance. The chemical and physical properties of KG-33 glass ensure high resistance to heat shock and chemical attack. Kimble Low Form Beakers Item Code Capacity Graduations Range (mL) Graduations Interval (mL) OD x Height Pack Size Unit KIM14000-10 10mL - - 25x34mm Each Each/Pack of 12/Case of 48 KIM14000-20 * 20mL 5-15 5 32x41mm Each Case of 48 KIM14000-30 * 30mL 5-25 10 35x53mm Each Case of 48 KIM14000-50 * 50mL 10-40 10 42x53mm Each Pack of 12/Case of 48 KIM14000-100 100mL 20-80 10 50x70mm Each Each/Pack of 12/Case of 48 KIM14000-150 150mL 20-140 20 57x81mm Each Each/Pack of 12/Case of 48 KIM14000-250 250mL 25-200 25 68x88mm Each Each/Pack of 12/Case of 48 KIM14000-400 400mL 50-325 25 77x106mm Each Each/Pack of 12/Case of 48 KIM14000-600 600mL 50-500 50 88x122mm Each Each/Case of 6 KIM14000-800 * 800mL 50-750 50 99x136mm Each Pack of 6/Case of 24 KIM14000-1000 1,000mL 100-1000 50 107x145mm Each Each/Pack of 6/Case of 24 KIM14000-1500 * 1,500mL 200-1400 100 120x165mm Each Pack of 4/Case of 16 KIM14000-2000 2,000mL 200-2000 100 130x190mm Each Each/Pack of 4/Case of 8 KIM14000-4000 * 4,000mL 500-3500 250 161x250mm Each Case of 6 7 Containerware Containerware Heavy Duty Beakers KIMAX beakers with thick uniform walls throughout and extra wall thickness built into the evenly tooled top rim. Spout is designed for optimum performance. Heavy construction is intended to prolong life with harder than normal usage (i.e. mechanical shock). Not recommended for use on hot plates where significant thermal gradients exist due to lack of agitation of contents or absence of a temperature control. All sizes have a durable matte finish marking area and a white graduated scale. Designed from ASTM Specification E960, Type II requirements. Laboratory Glassware Catalogue 2012/13 Kimble KIMAX Beaker, Spouted, Heavy Duty, Low Form, Double Capacity White Colour Scale 8 Item Code Capacity Graduations Range (mL) Graduations Interval (mL) OD x Height Pack Size Unit KIM14005-250 250mL 25-200 25 67x92mm Each Case of 48 KIM14005-400 400mL 25-325 25 77x114mm Each Case of 48 KIM14005-600 600mL 50-500 50 87x122mm Each Case of 36 KIM14005-1000 1,000mL 100-1000 50 107x152mm Each Case of 24 KIM14005-2000 2,000mL 200-1800 200 130x190mm Each Case of 8 KIM14005-4000 4,000mL 500-3500 500 161x252mm Each Case of 4 * denotes products not stocked Schott Duran Philips Beakers, With Spout Item Code Capacity Diameter Height Pack Size Unit SCH2114129 * 150mL 59mm 87mm 10 pcs Each SCH2114136 * 250mL 68mm 105mm 10 pcs Each SCH2114144 * 500mL 86mm 142mm 10 pcs Each Containerware >> Heavy Duty & Philips Beakers Philips Beakers 9 Containerware Containerware Media Bottles • Enhanced graduations • Permanent white enamel marking spot • GL 45 screw thread • Clear (natural), drip-free, replaceable polypropylene pour ring • Linerless • Autoclavable (to 140°C) • Polypropylene cap Laboratory Glassware Catalogue 2012/13 Fisherbrand Graduated Laboratory Bottles, with Polypropylene Screw Cap and Pouring Ring Item Code Capacity Graduations Range (mL) Graduations Interval (mL) Approx. OD x Height Pack Size (Unassembled) Unit FSBFB33144 100mL 20-80 10 56x100mm Each Case of 10 FSBFB33145 250mL 50-200 25 70x138mm Each Case of 10 FSBFB33146 500mL 100-400 50 86x176mm Each Case of 10 FSBFB33147 1,000mL 100-900 50 101x225mm Each Case of 10 FSBFB33148 2,000mL 400-1800 100 136x262mm Each Each FSBFB33180 5,000mL 1000-4000 250 186x355mm Each Each FSBFB33181 10,000mL 2000-8000 500 234x435mm Each Each Fisherbrand Screw Caps and Pouring Rings Item Code 10 Description GL Thread Colour Pack Size Unit FSBGLBBC Screw cap PP 45 Blue Each Case of 10 FSBGLBBR Pouring ring PP 45 Clear Each Case of 10 FSBGLBRC Screw cap PBTP with liner 45 Red Each Case of 10 * denotes products not stocked Item Code Capacity GL Thread Width (mm) Height (mm) Pack Size Unit SCH21801175 50mL 32 46 87 Each Case of 10 SCH21801245 100mL 45 56 100 Each Case of 10 SCH21801365 250mL 45 70 138 Each Case of 10 SCH21801545 1,000mL 45 101 225 Each Case of 10 SCH21801635 2,000mL 45 136 260 Each Case of 10 Schott Duran Screw Caps and Pouring Rings Item Code Description GL Thread Colour Pack Size Unit SCH2923928 Screw cap PP 45 Blue Each Case of 10 SCH2924228 Pouring ring PP 45 Blue Each Case of 10 Containerware >> Media Bottles Schott Duran Graduated Laboratory Bottles, with Polypropylene Screw Cap and Pouring Ring The RAY-SORB® process provides a shield to protect light sensitive products. Less than 1% transmission below 400 nm and reduced (5%) from 400-600 nm as compared to untreated, clear, borosilicate glass. Bottles are provided with enhanced graduation scale; cap and drip-free pour ring included. Kimble Graduated Laboratory Bottles, RAY-SORB, with Polypropylene Scew Cap Item Code KIM14399-500 Capacity * 500mL Graduations Range (mL) Graduations Interval (mL) OD x Height* Pack Size Unit 100-400 50 86x176mm Each Each KIM14399-1000 * 1,000mL 100-900 50 101x225mm Each Each KIM14399-2000 * 2,000mL 400-1800 100 136x262mm Each Each KIM14399-5000 * 5,000mL KIM14399-10000 * 10,000mL 1000-4500 250 186x355mm Each Each 2000-9000 500 234x435mm Each Each * Approximate OD x Height Unassembled 11 Containerware Containerware Boston Bottles Cospak Bottles, Clear and Amber, Round, Caps Sold Separately Item Code COSH0529 Type * Clear bottle Capacity Neck Finish Height Diameter Pack Size Unit 50mL 24mm 86mm 38mm 220pcs Each COSH0936 * Clear bottle 100mL 24mm 107mm 47mm 56pcs Each COSH1631 * Clear bottle 200mL 24mm 136mm 59mm 39pcs Each COSH721 * Amber bottle 100mL 24mm 109.4mm 45.9mm 122pcs Each COSH720 * Amber bottle 200mL 24mm 135.9mm 57mm 82pcs Each COSH725 Amber bottle 500mL 28mm 183.7mm 75.4mm 25pcs Each COSH4701 Amber bottle 1,000mL 33mm 206mm 96mm 12pcs Each COS2450 * White wadded cap 24mm Each Each COS2855 White wadded cap 28mm Each Each COS3331 * White wadded cap 33mm Each Each Laboratory Glassware Catalogue 2012/13 Available in Australia Only 12 * denotes products not stocked Containerware >> Boston Bottles • Boston round amber Type III glass bottle • Caps for 125mL and 250mL sizes are ultrasonically bonded with a .125” Teflon®-lined silicone liner • Caps for 500mL and 1000mL sizes are equipped with a friction-fit Teflon® liner which is easily replaced if necessary • Polypropylene closure. Excellent for water sampling. Recommended for UV light sensitive samples • I-CHEM Certified® 200 and 300 Series bottles are guaranteed to meet the EPA’s Performance Based Specifications for Metals (Group 1) and SemiVolatiles/Pesticides/PCBs (Group 2) analysis Kimble Chase Boston Round Bottles Item Code Type Capacity Group Closure Pack Size Unit NALICHEM249-0250 * Round amber bottle 250mL 1&2 24-414 Each Case of 12 NALICHEM249-0500 * Round amber bottle 500mL 1&2 28-400 Each Case of 12 NALICHEM249-1000 NALICHEM241-0250 Round amber bottle * Tall wide mouth amber bottle 1,000mL 1&2 33-430 Each Case of 12 250mL 1&2 45-400 Each Case of 12 13 Containerware Containerware Erlenmeyer Flasks Synonymous with quality and affordability, the range of LabServ glassware offers durability at competitive prices. Buy quality, reusable glass flasks at disposable prices. Use LabServ borosilicate glass flasks for routine measurement, mixing and gentle heating. Chemically resistant to most solvents, acids and bases. LabServ Erlenmeyer Flasks, Narrow Neck, Graduated Item Code Laboratory Glassware Catalogue 2012/13 LBS20401-02-50 Capacity * 50mL Neck OD Flask OD Height Pack Size Unit 26mm 54mm 80mm Each Case of 192 LBS20401-02-100 100mL 32mm 66mm 106mm Each Case of 192 LBS20401-02-150 * 150mL 32mm 75mm 124mm Each Case of 144 LBS20401-02-250 250mL 34mm 85mm 140mm Each Case of 72 LBS20401-02-300 * 300mL 34mm 90mm 162mm Each Case of 48 LBS20401-02-500 500mL 38mm 103mm 184mm Each Case of 48 LBS20401-02-1L * 1,000mL 45mm 131mm 214mm Each Case of 24 LBS20401-02-2L 2,000mL 50mm 166mm 280mm Each Case of 12 LBS20401-02-3L 3,000mL 50mm 187mm 310mm Each Case of 6 LBS20401-02-5L 5,000mL 50mm 220mm 365mm Each Case of 6 LabServ Erlenmeyer Flasks, Wide Neck, Graduated 14 Item Code Capacity Neck OD Flask OD Height Pack Size Unit LBS20401-04-250 250mL 34mm 85mm 140mm Each Case of 72 LBS20401-04-500 * 500mL 34mm 105mm 175mm Each Case of 48 LBS20401-04-1L * 1,000mL 42mm 131mm 220mm Each Case of 24 * denotes products not stocked Item Code Capacity Flask OD Pack Size Unit GLS075.202.01 * 50mL 51mm 10pcs Each GLS075.202.02 * 100mL 64mm 10pcs Each GLS075.202.03 * 150mL 74mm 10pcs Each GLS075.202.04 * 250mL 85mm 10pcs Each GLS075.202.05 * 500mL 105mm 10pcs Each GLS075.202.06 * 1,000mL 131mm 10pcs Each Containerware >> Erlenmeyer Flasks Glassco Erlenmeyer Flasks, with PTFE Lined Screw Cap, Graduated Kimble brand KIMAX erlenmeyer flasks, reinforced beaded top with capacity scale. All flasks have durable white ceramic enamel scales to indicate approximate volumes at various levels, useful in measuring and mixing solutions where a high degree of accuracy is unnecessary. Designed from ASTM Specification E1404, Type I, Class 1 requirements. Kimble Erlenmeyer Flasks, Narrow Neck Item Code Capacity Graduations Range (mL) Graduations Interval (mL) Widest Height (mm) Diameter (mm) Pack Size Unit KIM26500-25 * 25mL 10-25 5 39 65 Each Case of 48 KIM26500-125 * 125mL 50-125 25 66 108 Each Case of 48 KIM26500-250 250mL KIM26500-500 * 500mL 50-225 25 82 130 Each Case of 48 100-500 50 102 174 Each Case of 36 KIM26500-1000 * 1,000mL 250-1000 50 128 213 Each Case of 24 KIM26500-2000 * 2,000mL 600-2000 100 161 275 Each Case of 8 15 Containerware Containerware Kimble Erlenmeyer Flasks, Wide Neck Item Code Capacity Graduations Range (mL) Graduations Interval (mL) Widest Height (mm) Diameter (mm) Pack Size Unit KIM26650-125 125mL 50-125 25 66 Each Case of 48 KIM26650-250 250mL KIM26650-500 * 500mL 108 50-22 25 77 130 Each Case of 48 100-500 50 97 172 Each Case of 36 * 1,000mL 250-1000 50 122 216 Each Case of 24 * 2,000mL 600-2000 200 161 265 Each Case of 8 Laboratory Glassware Catalogue 2012/13 KIM26650-1000 KIM26650-2000 Kimble Erlenmeyer Filtering Flasks, with Capacity Scale and Side Tubulation Item Code KIM27060-500 16 Capacity * 500mL Graduations Interval Subdivision Widest Height mm Pack Size Diameter (mm) Unit 150-500 50 104 Case of 18 190 Each KIM27060-1000 1,000mL 300-1000 50 135 238 Each Case of 12 KIM27060-2000 * 2,000mL 600-2000 100 168 300 Each Each * denotes products not stocked Save money and space by getting a variety of sizes without having to order case quantities of each size. They provide precisely what you need, when you need it, without the extras that could slow you down. Kimble Lab Starter Packs, One of Each Size Included Item Code Type Sizes (mL) Pack Size Unit KIM14080-01 * Beakers 50, 100, 250, 600, 1000 5pcs Each KIM14085-01 * Heavy duty beakers 250, 400, 600, 1000 4pcs Each KIM26520-1 * Erlenmeyer flasks 10, 25, 50, 100, 250 5pcs Each KIM20024-01 * Cylinders 20, 125, 250, 500, 1000 5pcs Each Containerware >> Erlenmeyer Flasks & Starter Packs Starter Packs 17 Containerware Containerware Plastic Coated Glassware KimCote® Plastic-Coated Glassware for an Added Measure of Safety. Plastic coating on glassware Prevents & contains spills in broken glassware Ultra-clear coating Improved sample viewing Non-slip coating surface Easier handling in the lab Steam autoclavable Easy to clean and sterilise Chemically resistant Use with hazardous chemicals Odour free coating No noxious fumes present Laboratory Glassware Catalogue 2012/13 KimCote® protective glassware coating goes beyond traditional coatings. Should a break occur, KimCote® will reduce the hazards of shattered glass and leakage of toxic or corrosive chemicals. It is ultra-clear, extremely durable, autoclavable and resistant to many common laboratory chemicals. KimCote®’s unique texture also provides a non-slip handling surface, wet or dry. 18 Kimble Plastic Coated Media Bottles Item Code Capacity Graduations Range (mL) Intervals (mL) Approx. OD Approx. Height Pack Size Unit KIMKC14395-100 * 100mL 20-80 10 56mm 100mm 4pcs Each KIMKC14395-250 * 250mL 50-200 25 70mm 138mm 4pcs Each KIMKC14395-500 * 500mL 100-400 50 86mm 176mm 4pcs Each KIMKC14395-1000 * 1,000mL 100-900 50 101mm 225mm 4pcs Each KIMKC14395-2000 * 2,000mL 400-1800 100 136mm 262mm 4pcs Each KIMKC14395-5000 * 5,000mL 1000-4000 250 186mm 355mm Each Each KIMKC14395-10000 * 10,000mL 2000-8000 500 234mm 435mm Each Each * denotes products not stocked Item Code Capacity Graduations Range (mL) Subdivisions (mL) ±Tol (mL) Approx. Height Pack Size Unit KIMKC20028W-100 * 100mL 2-100 1 0.4 255mm Each Each KIMKC20028W-250 * 250mL 10-250 2 0.8 330mm Each Each KIMKC20028W-500 * 500mL 25-500 5 1.3 375mm Each Each KIMKC20028W-1000 * 1,000mL 50-1000 10 2.5 460mm Each Each KIMKC20028W-2000 * 2,000mL 100-2000 20 6 520mm Each Each Containerware >> Plastic Coated Glassware Kimble Plastic Coated Cylinders, Graduated, with Bumper Kimble Plastic Coated Erlenmeyer Flasks, with Screw Cap, Wide Mouth Item Code Capacity Approx. Widest Diameter Approx. Height with Cap GPI Thread Finish Pack Size Unit KIMKC26720-250 * 250mL 81mm 130mm GL45 6pcs Each KIMKC26720-500 * 500mL 102mm 165mm GL45 6pcs Each KIMKC26720-1000 * 1,000mL 128mm 205mm GL45 4pcs Each KIMKC26720-2000 * 2,000mL 161mm 265mm GL45 2pcs Each 19 Containerware Containerware Kimble Plastic Coated Volumetric Flasks, with Glass Stopper Item Code Capacity ±Tol (mL) Stopper Size Approx. Height with Pack Size Stopper Unit * 100mL 0.08 13 180mm 12pcs Each KIMKC28014-250 * 250mL 0.12 16 250mm 12pcs Each KIMKC28014-500 * 500mL 0.2 19 287mm 12pcs Each KIMKC28014-1000 * 1,000mL 0.3 22 338mm 4pcs Each KIMKC28014-2000 * 2,000mL 0.5 27 400mm 2pcs Each Laboratory Glassware Catalogue 2012/13 KIMKC28014-100 Kimble Plastic Coated Filter Flasks, Heavy-wall, 6mm Side Arm Item Code 20 Capacity Stopper Size Pack Size Unit KON953760-0122 * 125mL 5 Each Each KON953760-1002 * 1,000mL 8 Each Each KON953760-2002 * 2,000mL 8 Each Each KON953760-4002 * 4,000mL 8 Each Each * denotes products not stocked Volumetric Flasks 22 Measuring Cylinders 25 Mixing Cylinders 27 Burettes28 Automatic Burettes 29 Pipettes30 volumetric glassware Volumetric Glassware Volumetric Glassware Volumetric Flasks Synonymous with quality and affordability, the range of LabServ glassware offers durability at competitive prices. Buy quality, reusable glass flasks at disposable prices. Use LabServ borosilicate glass flasks for routine measurement, mixing and gentle heating. Chemically resistant to most solvents, acids and bases. Laboratory Glassware Catalogue 2012/13 LabServ Volumetric Flasks, Polyethylene Stopper, Class A 22 Item Code Capacity Accuracy Limits ±mL Stopper Size OD x Height Pack Size Unit LBS40620-25 25mL 0.03 10/13 37x110mm Each Case 120 LBS40620-50 50mL 0.05 10/13 49x140mm Each Case of 50 LBS40620-100 100mL 0.1 12.5/14 60x170mm Each Case of 50 LBS40620-250 250mL 0.15 14.5/15 80x220mm Each Case of 36 LBS40620-500 500mL 0.25 18.8/17 100x265mm Each Case of 24 LBS40620-1000 1,000mL 0.4 18.8/17 127x315mm Each Case of 15 LBS40620-2000 2,000mL 0.6 24/20 160x375mm Each Case of 12 LBS40620-5000 5,000mL 1.2 34.5/35 221x470mm Each Case of 6 * denotes products not stocked Glassco Volumetric Flasks, Polypropylene Stopper, Class A, as per DIN ISO 1042 Standards, Conformity Batch Certified Item Code Capacity Tolerance Limits ±mL Stopper Size Pack Size Unit GLS130.202.01 5mL 0.025 10/19 Each Case of 2 GLS130.202.02 10mL 0.025 10/19 Each Case of 2 GLS130.202.02A 20mL 0.04 10/19 Each Case of 2 GLS130.202.03 25mL 0.04 10/19 Each Case of 2 GLS130.202.04 50mL 0.06 12/21 Each Case of 2 GLS130.202.05 100mL 0.1 14/23 Each Case of 2 GLS130.202.06 200mL 0.15 14/23 Each Case of 2 GLS130.202.07 250mL 0.15 14/23 Each Case of 2 GLS130.202.08 500mL 0.25 19/26 Each Case of 2 GLS130.202.09 1,000mL 0.4 24/29 Each Case of 2 GLS130.202.10 2,000mL 0.6 29/32 Each Each Section >> General Glassware Sub-Section >> Volumetric Flasks Glassco volumetric flasks are made from ASTM E-438 Type 1 Class A heat resistant BORO 3.3 glass that meets ISO 1042 standards. The calibration is done on automatic computer controlled machines and the flasks are calibrated to contain according to the ISO tolerance standards. These are supplied with polypropylene stoppers in both amber and clear glass. All Class A flasks are printed in blue colour. The meniscus mark is diamond ground for longer persistence and better accuracy. 23 Laboratory Glassware Catalogue 2012/13 Volumetric Glassware Volumetric Glassware 24 Glassco Volumetric Flasks, Amber, Polypropylene Stopper, Class A, as per DIN ISO 1042 Standards, Conformity Batch Certified Item Code GLS130.202.01A Capacity * 5mL Tolerance Limits ±mL Stopper Size Pack Size Unit 0.025 Each Case of 2 10/19 GLS130.202.02AB * 10mL 0.025 10/19 Each Case of 2 GLS130.202.04A * 25mL 0.04 10/19 Each Case of 2 GLS130.202.05A * 50mL 0.06 12/21 Each Case of 2 GLS130.202.06A * 100mL 0.1 14/23 Each Case of 2 GLS130.202.07A * 200mL 0.15 14/23 Each Case of 2 GLS130.202.08A * 250mL 0.15 14/23 Each Case of 2 GLS130.202.09A * 500mL 0.25 19/26 Each Case of 2 GLS130.202.10A * 1,000mL 0.4 24/29 Each Case of 2 GLS130.202.11A * 2,000mL 0.6 29/32 Each Case of 2 Kimble Volumetric Flasks, RAY-SORB, with PTFE Stopper Item Code Capacity Tolerance Limits ±mL Stopper Size Approx. Height with Stopper Pack Size Unit KIM92822F-5 * 5mL 0.08 13 94mm 6pcs Each KIM92822F-10 * 10mL 0.08 13 97mm 6pcs Each KIM92822F-20 * 20mL 0.08 13 127mm 6pcs Each KIM92822F-25 * 25mL 0.08 13 127mm 6pcs Each KIM92822F-50 * 50mL 0.08 13 147mm 6pcs Each KIM92822F-100 * 100mL 0.1 16 175mm 6pcs Each KIM92822F-200 * 200mL 0.2 19 217mm 6pcs Each KIM92822F-250 * 250mL 0.2 19 269mm 6pcs Each KIM92822F-500 * 500mL 0.2 19 300mm 6pcs Each KIM92822F-1000 * 1,000mL 0.3 22 328mm Each Each KIM92822F-2000 * 2,000mL 0.5 27 392mm Each Each * denotes products not stocked Glassco measuring cylinders are made from ASTM E-438 Type 1 Class A BORO 3.3 glass that meets ISO 4788 standards. The calibration is performed on automatic computer controlled machines, and cylinders are calibrated to contain according to the ISO tolerance standards. All Class A cylinders are printed in blue colour. Glassco Measuring Cylinders, Hexagonal Base, Class A, as per DIN EN ISO 4788 & USP Standards, with Lot Certificate Item Code Capacity Subdivision Tolerance ±mL Pack Size Unit GLS139.202.01A 10mL 0.2 0.1 Each Case of 2 GLS139.202.02A 25mL 0.5 0.25 Each Case of 2 GLS139.202.03A 50mL 1 0.5 Each Case of 2 GLS139.202.04A 100mL 1 0.5 Each Case of 2 GLS139.202.05A 250mL 2 1 Each Case of 2 GLS139.202.06A 500mL 5 2.5 Each Case of 2 GLS139.202.07A 1,000mL 10 5 Each Each GLS139.202.08A 2,000mL 20 10 Each Each Glassco Measuring Cylinders, Hexagonal Base, Class A, as per DIN EN ISO 4788 & USP standards, with Individual Work Certificate, Serially Numbered Item Code Capacity Subdivision Tolerance ±mL Pack Size Section >> Glassware Volumetric Sub-Section >> Volumetric Flasks & Measuring Cylinders Measuring Cylinders Unit GLS139.223.01A * 10mL 0.2 0.1 Each Case of 2 GLS139.223.02A * 25mL 0.5 0.25 Each Case of 2 GLS139.223.03A * 50mL 1 0.5 Each Case of 2 GLS139.223.04A * 100mL 1 0.5 Each Case of 2 GLS139.223.05A * 250mL 2 1 Each Case of 2 GLS139.223.06A * 500mL 5 2.5 Each Case of 2 GLS139.223.07A * 1,000mL 10 5 Each Each GLS139.223.08A * 2,000mL 20 10 Each Each 25 Laboratory Glassware Catalogue 2012/13 Volumetric Glassware Volumetric Glassware 26 Glassco Measuring Cylinders, Hexagonal Base, Class A, according to USP and ASTM E1272 Standards, Graduated To Deliver (TD), with Individual Work Certificate, Serially Numbered Item Code GLS139.220.01A Capacity * 10mL Subdivision Tolerance ±mL Pack Size Unit 0.2 0.1 Each Case of 2 GLS139.220.02A * 25mL 0.5 0.15 Each Case of 2 GLS139.220.03A * 50mL 1 0.25 Each Case of 2 GLS139.220.04A * 100mL 1 0.5 Each Case of 2 GLS139.220.05A * 250mL 2 1 Each Case of 2 GLS139.220.06A * 500mL 5 1.5 Each Case of 2 GLS139.220.07A * 1,000mL 10 3 Each Each GLS139.220.08A * 2,000mL 20 6 Each Each Glassco Measuring Cylinders, Detachable Polypropylene Base, Protection Collar, Class B, as per DIN EN ISO 4788 Standards Item Code Capacity Subdivision Tolerance ±mL Pack Size Unit GLS137.202.02 10mL 0.2 0.02 Each Case of 10 GLS137.202.03 25mL 0.5 0.05 Each Case of 10 GLS137.202.04 50mL 1 1 Each Case of 10 GLS137.202.05 100mL 1 1 Each Case of 10 GLS137.202.06 250mL 2 2 Each Case of 10 * denotes products not stocked Glassco Mixing Cylinders, Polypropylene Stopper, Round Base, Class A, as per DIN EN ISO 4788 Standards Item Code GLS141.202.02 Capacity * 10mL Subdivision Tolerance ±mL Pack Size Unit 0.2 0.1 Each Case of 2 GLS141.202.03 25mL 0.5 0.25 Each Case of 2 GLS141.202.04 50mL 1 0.5 Each Case of 2 GLS141.202.05 100mL 1 0.5 Each Case of 2 GLS141.202.06 250mL 2 1 Each Case of 2 GLS141.202.07 500mL 5 2.5 Each Case of 2 GLS141.202.08 1,000mL 10 5 Each Each GLS141.202.09 * 2,000mL 20 10 Each Each Section >> Glassware Volumetric Sub-Section >> Measuring & Mixing Cylinders Mixing Cylinders 27 Volumetric Glassware Volumetric Glassware Burettes Glassco burettes are manufactured from ASTM E-438 Type 1 Class A BORO 3.3 heat resistant glass which meets ISO 385 and USP standards. Each and every piece is calibrated to deliver. All Class A burettes are manufactured from precision bore tubing for accuracy. The burettes are calibrated on computer controlled machines to give the most accurate results and then are rechecked at the quality control centre. Class A burettes come with either conformity batch or individual work certification. All Class A burettes are printed in blue colour and have a waiting time of 30 seconds; Class B burettes are printed in amber colour and have no waiting time. Laboratory Glassware Catalogue 2012/13 Glassco Straight Bore Burettes, PTFE Key Stopcock, Schellbach Stripe, as per DIN ISO 385 standards, with Lot Certificate 28 Item Code Capacity Subdivision Tolerance ±mL Pack Size Unit GLS114.202.04A 10mL 0.05 0.02 Each Each GLS114.202.05A 25mL 0.1 0.03 Each Each GLS114.202.06A 50mL 0.1 0.05 Each Each GLS114.202.07A * 100mL Each Each Glassco Straight Bore Burettes, Glass Key Stopcock, Schellbach Stripe, as per DIN ISO 385 standards, with Lot Certificate Item Code GLS110.202.01A Capacity * 10mL Subdivision Tolerance ±mL Pack Size Unit 0.05 0.02 Each Each GLS110.202.02A * 25mL 0.1 0.03 Each Each GLS110.202.03A * 50mL 0.1 0.05 Each Each GLS110.202.04A * 100mL Each Each * denotes products not stocked Item Code GLS113.202.01 Capacity * 10mL Subdivision Tolerance ±mL Pack Size Unit 0.05 0.02 Each Each GLS113.202.02 * 25mL 0.1 0.03 Each Each GLS113.202.03 * 50mL 0.1 0.05 Each Each GLS113.202.04 * 100mL Each Each Automatic Burettes Glassco burettes are manufactured from ASTM E-438 Type 1 Class A BORO 3.3 heat resistant glass which meets ISO 385 and USP standards. Each and every piece is calibrated to deliver. All Class A burettes are manufactured from precision bore tubing to maintain accuracy. These burettes come with either PTFE needle valve stopcocks or intermediate PTFE key stopcocks. Burettes feature printing in blue colour for better visibility. Section >> Glassware Volumetric Sub-Section >> Burettes Glassco Burettes, Screw Type PTFE Needle Valve Stopcock, as per DIN ISO 385 and USP standards, with Lot Certificate Glassco Automatic Burettes, with Intermediate Stopcock, PTFE Key and Needle Valve Stopcock, Schellbach Stripe, as per DIN ISO 385 and USP Standards, Class AS, Conformity Certified Item Code Capacity Subdivision Tolerance ±mL Bottle Capacity Pack Size Unit GLS118.240.01 * 10mL 0.05 0.02 500mL Each Each GLS118.240.02 * 25mL 0.1 0.03 2,000mL Each Each GLS118.240.03 * 50mL 0.1 0.05 2,000mL Each Each 29 Volumetric Glassware Volumetric Glassware Pipettes Glassco volumetric pipettes are manufactured in compliance with DIN ISO 648 standards. These pipettes are calibrated to deliver. All volumetric pipettes are calibrated by automatic machine, and the final quality check is performed at the quality control centre. The volumetric pipettes are printed in amber colour which is fused into the glass. Glassco Volumetric Pipettes, One Mark, Class A, as per DIN ISO 648 Standards, with Batch Certificate Laboratory Glassware Catalogue 2012/13 Item Code 30 Capacity Colour Code Tolerance ±mL Pack Size Unit GLS123.202.01 1mL Blue 0.007 Each Case of 5 GLS123.202.02 2mL Orange 0.01 Each Case of 5 GLS123.202.03 5mL White 0.015 Each Case of 5 GLS123.202.04 10mL Red 0.02 Each Case of 5 GLS123.202.05 20mL Yellow 0.03 Each Case of 5 GLS123.202.06 25mL Blue 0.03 Each Case of 5 GLS123.202.07 50mL Red 0.05 Each Case of 5 GLS123.202.08 100mL Yellow 0.08 Each Case of 5 * denotes products not stocked Section >> Glassware Volumetric Sub-Section >> Pipettes Glassco graduated pipettes are manufactured to meet ISO 835 standards. These pipettes are calibrated to deliver. All graduated pipettes are calibrated by automatic machine, and the final quality check is performed at the quality control centre. The graduated pipettes are printed in amber colour which fuses into the glass. All Class A pipettes have a waiting time of 5 seconds. Glassco Graduated Pipettes, Class AS, as per DIN ISO 648 Standars, with Batch Certificate Item Code Capacity Colour Code Tolerance ±mL Pack Size Unit GLS125.202.01 1mL Yellow 0.007 Each Case of 5 GLS125.202.02 * 2mL GLS125.202.03 5mL Black 0.01 Each Case of 5 Red 0.03 Each Case of 5 GLS125.202.04 10mL Orange 0.05 Each Case of 5 GLS125.202.06 25mL White 0.1 Each Case of 5 Kimble Chase pasteur pipettes are made of disposable soda lime glass. Available sterile and non-sterile, plugged and non-plugged. For one time use in the transfer of small volumes. Kimble Chase Pasteur Pipettes, Disposable, Soda Lime Glass Item Code Overall Length Type Tip Length Body Length OD Pack Size Unit CSEJ5000 5.75 inch Non-plugged 2.25 inch 3.5 inch 7mm 1000pcs Each CSEJ5000P 5.75 inch Plugged 2.25 inch 3.5 inch 7mm 1000pcs Each CSEJ9000 9 inch Non-plugged 5 inch 4 inch 7mm 1000pcs Each CSE63B.93P 9 inch Plugged 5 inch 4 inch 7mm 1000pcs Each Available in Australia Only 31 Volumetric Glassware Volumetric Glassware Kimble Chase Pasteur Pipettes, Disposable, Soda Lime Glass Item Code Overall Length Type Tip Length Body Length OD Pack Size Unit KIM63A54 145mm Non-plugged 57mm 89mm 7mm 250pcs Each/Case of 4 KIM63A54P 145mm Plugged 57mm 89mm 7mm 250pcs Each/Case of 4 230mm Non-plugged 127mm 102mm 7mm 250pcs Each/Case of 4 Plugged 127mm 102mm 7mm 250pcs Case of 4 KIM63B93 KIM63B93P * 230mm Available in New Zealand Only Kimble Chase Pasteur Pipettes, Sterile, Disposable, Soda Lime Glass Laboratory Glassware Catalogue 2012/13 Item Code 32 Overall Length Type Tip Length Body Length OD Pack Size Unit KIM63A55 * 5.75 inch Non-plugged 2.25 inch 3.5 inch 7mm 250pcs Each KIM63A55P * 5.75 inch Plugged 2.25 inch 3.5 inch 7mm 250pcs Each KIM63B95 * 9 inch Non-plugged 5 inch 4 inch 7mm 250pcs Each KIM63B95P * 9 inch Plugged 5 inch 4 inch 7mm 250pcs Each * denotes products not stocked BOD Bottles34 Gas Washing Bottles35 Counting Chambers36 Weighing Scoops37 Crystallising Dishes37 Funnels39 Desiccators40 Scintillation Vials41 Trident Vials42 Pathological Vials43 Petri Dishes44 Watch Glasses45 Separating Funnels46 Condensers47 Filtration Glassware49 Jars52 Babcock Bottles53 Mojonnier Tubes53 Miscellaneous54 Microscopy55 general glassware General Glassware General Glassware BOD Bottles Glassco BOD bottles are manufactured from ASTM E-438 Type 1 Class A BORO 3.3 glass. Glassco BOD Bottles, with Glass Stopper Item Code Capacity Diameter Height Pack Size Unit * 125mL 55mm 120mm Each Case of 2 GLS284.202.02 * 300mL 70mm 150mm Each Case of 2 Capacity Type Stopper Pack Size Unit 300mL Numbered 01-24 Glass robotic stopper Each Case of 24 * 300mL Numbered 25-48 Glass robotic stopper Each Case of 24 Laboratory Glassware Catalogue 2012/13 GLS284.202.01 Wheaton BOD Bottles Item Code WHE227497 WHE227497-02 Available in New Zealand Only. Other sizes available, please contact us for further information 34 * denotes products not stocked Bottles Item Code GLS286.202.01 Capacity * 125mL Pack Size Unit Each Each GLS286.202.02 * 250mL Each Each GLS286.202.03 * 500mL Each Each Pack Size Unit Heads Item Code Capacity GLS285.202.01 * 125mL Each Each GLS285.202.02 * 250mL Each Each GLS285.202.03 * 500mL Each Each General Glassware >> BOD Bottles & Gas Washing Bottles Gas Washing Bottles 35 General Glassware General Glassware Counting Chambers Boeco Haemacytometer, Neubauer Improved Bright Line, Includes Two Cover Glasses Item Code Type Pack Size Unit BOKBOE14 Double ruled Each Each Laboratory Glassware Catalogue 2012/13 Available in Australia Only. Schott Duran Haemacytometers, Neubauer Improved, Double Net Ruling, Includes Two Cover Glasses Item Code Type Depth Pack Size Unit SCH8100204 * Bright lined 0.1mm Each Each SCH8100104 * Standard 0.1mm Each Each Web Haemacytometer and Coverslips Item Code Type Depth WEBAC1000 Standard 0.1mm WEBZ5000 Coverslips Heamacytometer Size 22x25mm Pack Size Unit Each Each 10pcs Each Available in New Zealand Only. 36 * denotes products not stocked Glassco Weighing Scoops, with Open Tubular Arm Item Code Capacity Pack Size Unit GLS245.202.01 3mL Each Case of 10 GLS245.202.02 6mL Each Case of 10 GLS245.202.03 10mL Each Case of 10 Crystallising Dishes Manufactured from ASTM E-438 Type 1 Class A BORO 3.3 glass. These dishes conform to DIN and USP standards. The dishes are printed in white colour and feature a white marking area for use with pencil. Glassco Crystallising Dishes, without Spout Item Code Diameter Height Pack Size Unit GLS246.202.01 * 40mm 25mm Each Case of 10 GLS246.202.02 * 50mm 30mm Each Case of 10 GLS246.202.03 * 60mm 35mm Each Case of 10 GLS246.202.04 * 70mm 40mm Each Case of 10 GLS246.202.05 * 80mm 45mm Each Case of 10 GLS246.202.06 * 95mm 55mm Each Case of 10 General Glassware >> Counting Chambers, Weighing Scoops & Crystalising Dishes Weighing Scoops 37 Glassco Crystallising Dishes, with Spout Item Code Diameter Height Pack Size Unit GLS246.202.01S * 40mm 25mm Each Case of 10 GLS246.202.02S * 50mm 30mm Each Case of 10 GLS246.202.03S * 60mm 35mm Each Case of 10 GLS246.202.04S * 70mm 40mm Each Case of 10 GLS246.202.05S * 80mm 45mm Each Case of 10 GLS246.202.06S * 95mm 55mm Each Case of 10 Laboratory Glassware Catalogue 2012/13 General Glassware General Glassware 38 * denotes products not stocked General Glassware >> Crystalising Dishers & Funnels Funnels Glassco Funnels, with Short Stem, Borosilicate Glass Item Code Diameter Pack Size Unit GLS238.202.01 25mm Each Case of 10 GLS238.202.04 40mm Each Case of 10 GLS238.202.05 50mm Each Case of 10 GLS238.202.07 65mm Each Case of 10 GLS238.202.08 70mm Each Case of 10 GLS238.202.09 75mm Each Case of 10 GLS238.202.10 80mm Each Case of 10 GLS238.202.11 100mm Each Case of 10 GLS238.202.12 * 125mm Each Case of 10 GLS238.202.13 150mm Each Case of 10 Glassco Powder Funnels, Borosilicate Glass Item Code Diameter Cone Size Pack Size Unit GLS238.202.01P * 45mm 14/23 Each Case of 10 GLS238.202.02P * 70mm 14/23 Each Case of 10 GLS238.202.03P * 70mm 29/32 Each Case of 10 GLS238.202.04P * 80mm 29/32 Each Case of 10 GLS238.202.05P * 100mm 14/23 Each Case of 10 GLS238.202.06P * 100mm 29/32 Each Case of 10 39 General Glassware General Glassware Desiccators Glassco Desiccators, with Lid, Plain, Neutral Glass, with Porcelain Perforated Plate Laboratory Glassware Catalogue 2012/13 Item Code 40 Internal Diameter Pack Size Unit GLS249.202.01 * 150mm Each Each GLS249.202.02 * 210mm Each Each GLS249.202.03 * 250mm Each Each GLS249.202.04 * 300mm Each Each Glassco Desiccators, with Lid, Vacuum, Neutral Glass, with Porcelain Perforated Plate Item Code Internal Diameter Pack Size Unit GLS250.202.01 * 150mm Each Each GLS250.202.02 * 210mm Each Each GLS250.202.03 * 250mm Each Each GLS250.202.04 * 300mm Each Each * denotes products not stocked Kimble Chase scintillation vials are supplied with caps attached, in cellular trays with alpha numeric coordinates for fast, easy identification. Kimble Chase Scintillation Vials Item Code Capacity Cap material Cap Liner Cap Size Pack Size Unit KIM74502-7 7mL Urea Cork-backed foil 15mm 200pcs Case of 5 KIM74504-20 20mL Polypropylene Pulp-backed foil 22mm 500pcs Each General Glassware >> Desiccators & Scintillation Vials Scintillation Vials Wheaton Scintillation Vials (supplied with either Polypropylene or Urea caps) Item Code Capacity Cap material Cap Liner Cap Size Pack Size Unit WHE986541 20mL Polypropylene Metal foil 22mm 500pcs Each WHE986560 20mL Polypropylene Foamed polyethylene 24mm 500pcs Each WHE986561 20mL Polypropylene Metal foil 22mm 500pcs Each WHE986542 20mL Urea Metal foil 22mm 500pcs Each WHE986546 20mL Urea Polyseal 22mm 500pcs Each WHE986548 20mL Urea Polyethylene disc 22mm 500pcs Each Available in New Zealand Only. 41 General Glassware General Glassware Trident Vials Samco neutral glass vials will withstand moderate temperature change. Samco Trident Vials, Neutral Glass, without Closure Laboratory Glassware Catalogue 2012/13 Item Code 42 Capacity Form Height x Diameter Neck Bore Pack Size Unit SAMT101/V1 * 1.75mL Tall Form 36x11mm 5.5mm 882pcs Each SAMT101/V2 * 3.5mL Tall Form 46x12.5mm 5.5mm 666pcs Each SAMT101/V3 * 7.0mL Tall Form 58x17mm 9.0mm 399pcs Each SAMT101/V4 * 10.5mL Tall Form 67x17mm 9.0mm 399pcs Each SAMT101/V5 * 14.0mL Tall Form 72x20mm 13.0mm 264pcs Each SAMT101/V6 * 21.25mL Tall Form 86x21mm 13.0mm 231pcs Each SAMT101/V7 * 28.25mL Tall Form 96x23mm 15.5mm 190pcs Each SAMT102/V1 * 7.0mL Squat Form 42x20mm 13.0mm 264pcs Each SAMT102/V2 * 14.0mL Squat Form 58x23mm 15.5mm 190pcs Each Squat Form 27.5x21mm 21.0mm 140pcs Each SAMT102/V3 28.25mL * denotes products not stocked General Glassware >> Trident & Pathology Vials Samco Screw Caps for Trident Vials, Black Polypropylene, Foil-faced Wads Item Code Capacity Pack Size Unit SAMT001/C1 To fit T101/V1 and T101/V2 882pcs Each SAMT001/C3 * To fit T101/V3 and T101/V4 399pcs Each SAMT001/C5 * To fit T101/V5, T101/V6 and T102/V1 264pcs Each SAMT001/C7 * To fit T101/V7 and T102/V2 190pcs Each 140pcs Each SAMT002/C3 To fit T102/V3 Pathological Vials Samco moulded pathological vials are made of white flint glass, which has been sulphated for autoclaving. Spare caps are also available. Samco Pathological Vials, White Flint Glass, with Fitted Aluminium Rubber Lined Closure Item Code Capacity Type Neck Height x Diameter Pack Size Unit SAMG752/01 7.0mL Bijou Narrow Neck 48.5x21.9mm 288pcs Each SAMG752/02 * 14.0mL McCartney Narrow Neck 64.7x27.6mm 288pcs Each SAMG751/01 28.0mL Universal Wide Neck 82.5x28.6mm 144pcs Each 43 General Glassware General Glassware Petri Dishes KIMAX dishes have reinforced beaded edges to resist mechanical breakage and to help in centering the bottom inside the cover. Dishes remain clear after repeated use in wet or dry sterilisation cycles. Shelf packs contain twelve covers and twelve bottoms, which are packed in separate boxes. Designed from Federal Specification NNN-D-1478. Laboratory Glassware Catalogue 2012/13 Kimble Petri Dishes 44 Item Code Diameter Height Pack Size Unit KIM23060-6015 60mm 15mm Each Each/Pack of 12/Case of 72 KIM23060-10020 100mm 20mm Each Each/Pack of 12/Case of 72 KIM23060-15020 * 150mm 20mm Each Case of 24 Height Pack Size Unit * 40mm 12mm Each Case of 10 SCH2375540 60mm 15mm Each Case of 10 SCH2375542 * 80mm 15mm Each Case of 10 SCH2375545 * 100mm 10mm Each Case of 10 SCH2375546 100mm 15mm Each Case of 10 SCH2375548 * 100mm 20mm Each Case of 10 SCH2375551 * 120mm 20mm Each Case of 10 SCH2375552 * 150mm 25mm Each Case of 10 SCH2375556 * 180mm 30mm Each Case of 10 SCH2375559 * 200mm 30mm Each Case of 10 SCH2375561 * 200mm 50mm Each Case of 10 Schott Duran Petri Dishes, Steriplan, Soda Lime Glass Item Code SCH2375539 Diameter * denotes products not stocked Schott Duran Watch Glasses, with Fused Rim, Soda Lime Glass Item Code Diameter Pack Size Unit SCH2332124 * 40mm Each Case of 10 SCH2332132 * 50mm Each Case of 10 SCH2332134 * 60mm Each Case of 10 SCH2332138 * 70mm Each Case of 10 SCH2332141 * 80mm Each Case of 10 SCH2332143 * 90mm Each Case of 10 SCH2332146 * 100mm Each Case of 10 SCH2332151 * 120mm Each Case of 10 SCH2332152 * 125mm Each Case of 10 SCH2332157 * 150mm Each Case of 10 SCH2332161 * 200mm Each Case of 10 SCH2332166 * 250mm Each Each General Glassware >> Petri Dishers & Watch Glasses Watch Glasses 45 General Glassware General Glassware Separating Funnels Glassco separating funnels are produced from ASTM E-438 Type 1 Class A BORO 3.3 heat resistant glass. All Glassco funnels are manufactured as per ISO 4800 standard. The printing is done in white colour. Glassco Squibb Separating Funnels, Plain, PTFE Stopcock Item Code Laboratory Glassware Catalogue 2012/13 GLS149.202.02 Capacity * 50mL Stopper Size Bore Pack Size Unit 19/26 2.5mm Each Each GLS149.202.03 100mL 19/26 2.5mm Each Each GLS149.202.04 250mL 29/32 4mm Each Each GLS149.202.05 500mL 29/32 4mm Each Each GLS149.202.06 1,000mL 29/32 6mm Each Each GLS149.202.07 2,000mL 29/32 6mm Each Each Stopper Size Bore Pack Size Unit 19/26 2.5mm Each Each Glassco Pear Separating Funnels, Plain, PTFE Stopcock Item Code GLS152.202.02 Capacity * 50mL GLS152.202.03 100mL 19/26 2.5mm Each Each GLS152.202.05 500mL 29/32 4mm Each Each GLS152.202.06 1,000mL 29/32 6mm Each Each GLS152.202.07 * 2,000mL 29/32 6mm Each Each Glassco Cylindrical Dropping Funnels, Graduated, PTFE Stopcock Item Code 46 Capacity Stopper Size Bore Pack Size Unit GLS158.202.04 * 250mL 29/32 4mm Each Each GLS158.202.05 * 500mL 29/32 4mm Each Each GLS158.202.06 * 1,000mL 29/32 6mm Each Each * denotes products not stocked Glassco Liebig Condensers, Glass Hose Connections Item Code Effective Length Cone Size Socket Size Pack Size Unit GLS182.202.01 160mm 14/23 14/23 Each Each * 160mm 19/26 19/26 Each Each 250mm 19/26 19/26 Each Each GLS182.202.03 250mm 24/29 24/29 Each Each GLS182.202.04 * 300mm 19/26 19/26 Each Each GLS182.202.05 * 300mm 24/29 24/29 Each Each GLS182.202.06 * 300mm 29/32 29/32 Each Each GLS182.202.10 * 400mm 24/29 24/29 Each Each GLS182.202.11 * 400mm 29/32 29/32 Each Each Cone Size Socket Size Pack Size Unit GLS182.202.01A GLS182.202.02 General Glassware >> Separating Funnels & Condensers Condensers Glassco Coil Condensers, Glass Hose Connections Item Code Effective Length GLS183.202.01 * 160mm 14/23 14/23 Each Each GLS183.202.01A * 160mm 19/26 19/26 Each Each GLS183.202.03 * 250mm 19/26 19/26 Each Each GLS183.202.04 * 250mm 24/29 24/29 Each Each GLS183.202.04A * 250mm 29/32 29/32 Each Each GLS183.202.05 * 300mm 24/29 24/29 Each Each GLS183.202.06 * 300mm 29/32 29/32 Each Each GLS183.202.07 * 400mm 29/32 29/32 Each Each 47 General Glassware General Glassware Glassco Allihn Condensers, Glass Hose Connections Item Code Effective Length Cone Size Socket Size Pack Size Unit GLS190.202.05 * 160mm 14/23 14/23 Each Each GLS190.202.06 * 160mm 19/26 19/26 Each Each GLS190.202.07 * 250mm 14/23 14/23 Each Each GLS190.202.08 * 250mm 19/26 19/26 Each Each GLS190.202.09 * 250mm 24/29 24/29 Each Each GLS190.202.10 * 300mm 24/29 24/29 Each Each GLS190.202.11 * 300mm 29/32 29/32 Each Each GLS190.202.12 * 400mm 24/29 24/29 Each Each GLS190.202.13 * 400mm 29/32 29/32 Each Each Cone Size Socket Size Pack Size Unit Soxhlet Extractors Laboratory Glassware Catalogue 2012/13 Item Code 48 Capacity GLS211.202.04 * 100mL 29/32 45/40 Each Each GLS211.202.05 * 150mL 29/32 45/40 Each Each GLS211.202.06 * 250mL 29/32 45/40 Each Each GLS211.202.08 * 500mL 29/32 60/46 Each Each GLS211.202.09 * 1,000mL 29/32 71/51 Each Each * denotes products not stocked Glassco Filtration Assembly, 47mm, All Glass, with Funnel, Fritted Base, Cap and Clamp Item Code Funnel Flask Filter Diameter Pack Size Unit GLS258.202.01 300mL 1,000mL 47mm Each Each Millipore Glass Filter Holders, Borosilicate Glass Funnel and Base, Anodised Aluminium Spring Clamp, Silicone Stopper Filter Diameter Pack Size Unit Coarse-frit glass filter support 300mL 47mm Each Each PTFE-faced funnel and base 47mm Each Each Item Code Part MILXX1004700 MILXX1004710 Funnel Capacity 300mL General Glassware >> Condensers & Filtration Glassware Filtration Glassware 49 Laboratory Glassware Catalogue 2012/13 General Glassware General Glassware 50 Glassco Filter Gooch Crucibles, with Sintered Disc, Borosilicate Glass Item Code Capacity Porosity Pack Size Unit GLS255.G00.01 * 15mL 0 Each Case of 10 GLS255.G01.01 * 15mL 1 Each Case of 10 GLS255.G02.01 * 15mL 2 Each Case of 10 GLS255.G03.01 * 15mL 3 Each Case of 10 GLS255.G04.01 * 15mL 4 Each Case of 10 GLS255.G00.02 * 30mL 0 Each Case of 10 GLS255.G01.02 * 30mL 1 Each Case of 10 GLS255.G02.02 * 30mL 2 Each Case of 10 GLS255.G03.02 * 30mL 3 Each Case of 10 GLS255.G04.02 * 30mL 4 Each Case of 10 GLS255.G00.03 * 50mL 0 Each Case of 10 GLS255.G01.03 * 50mL 1 Each Case of 10 GLS255.G02.03 * 50mL 2 Each Case of 10 GLS255.G03.03 * 50mL 3 Each Case of 10 GLS255.G04.03 * 50mL 4 Each Case of 10 * denotes products not stocked Item Code Capacity Porosity Pack Size Unit GLS256.G00.01 * 35mL 0 Each Case of 2 GLS256.G01.01 * 35mL 1 Each Case of 2 GLS256.G02.01 * 35mL 2 Each Case of 2 GLS256.G03.01 * 35mL 3 Each Case of 2 GLS256.G04.01 * 35mL 4 Each Case of 2 GLS256.G00.02 * 80mL 0 Each Case of 2 GLS256.G01.02 * 80mL 1 Each Case of 2 GLS256.G02.02 * 80mL 2 Each Case of 2 GLS256.G03.02 * 80mL 3 Each Case of 2 GLS256.G04.02 * 80mL 4 Each Case of 2 GLS256.G00.03 * 200mL 0 Each Case of 2 GLS256.G01.03 * 200mL 1 Each Case of 2 GLS256.G02.03 * 200mL 2 Each Case of 2 GLS256.G03.03 * 200mL 3 Each Case of 2 GLS256.G04.03 * 200mL 4 Each Case of 2 GLS256.G00.04 * 500mL 0 Each Case of 2 GLS256.G01.04 * 500mL 1 Each Case of 2 GLS256.G02.04 * 500mL 2 Each Case of 2 GLS256.G03.04 * 500mL 3 Each Case of 2 GLS256.G04.04 * 500mL 4 Each Case of 2 GLS256.G00.05 * 1,000mL 0 Each Case of 2 GLS256.G01.05 * 1,000mL 1 Each Case of 2 GLS256.G02.05 * 1,000mL 2 Each Case of 2 GLS256.G03.05 * 1,000mL 3 Each Case of 2 GLS256.G04.05 * 1,000mL 4 Each Case of 2 General Glassware >> Filtration Glassware Glassco Buchner Funnels, with Sintered Disc, Borosilicate Glass 51 General Glassware General Glassware Jars Cospak Clear Jars, Caps Sold Separately Item Code Type Capacity Neck Finish Height Diameter Pack Size Unit COSH0466 * Clear jar 30mL 38mm 46mm 40mm 160pcs Each COSTG1146 * Clear jar 125mL 48mm 42pcs Each COSH15131 Clear jar 250mL 63mm 104mm 67mm 48pcs Each COSJA500C * Clear jar 500mL 63mm 148mm 78mm COS3830 White poly cap 50pcs Each 38mm Each Each COS4832 * Black phenolic wadded cap 48mm Each Each COS6330 * White poly cap 63mm Each Each COS6331 * White poly wadded cap 63mm Each Each Laboratory Glassware Catalogue 2012/13 Available in Australia Only 52 Solindex Jars Item Code Type Pack Size Unit LABSOL003 Jar solindex Each Each/Case of 25 LABSOL001 * Mixing unit for ADMI solindex Each Each LABSOL002 * Solindex blades Each Each LABSOL003 Jar solindex Each Each/Case of 25 Available in New Zealand Only * denotes products not stocked Kimble Chase Babcock Bottles Item Code Type Pack Size Unit KIM509-50 * 50% 9g paley cheese Each Case of 3 KIM2085S-50 * Cream test 9g sealed Each Case of 12 Available in Australia Only General Glassware >> Jars & More Babcock Bottles Mojonnier Tubes Funke Gerber Mojonnier Tubes Item Code Type Stopper Pack Size Unit FG3870 Round bulb Cork Each Each FG3871 Flat topped bulb Cork Each Each Available in New Zealand Only Mojonnier Flasks Item Code PEDMAJSTD Type * Medium wall Pack Size Unit Each Each Available in Australia Only 53 General Glassware General Glassware Stirring Rods Item Code Type Pack Size Unit CSUROD 6x200mm Each Each/Case of 10 6x300mm Each Each Available in New Zealand Only RBI434408 Laboratory Glassware Catalogue 2012/13 Available in Australia Only Miscellaneous Item Code Type Volume Cone Pack Size Unit CSUTILT/10 Tilt measure 10mL 24/29 Each Each CSUWBOAT.10 Weighing boat glass 10mL Each Each Available in New Zealand Only 54 * denotes products not stocked • LabServ microscope slides are cut from water white, corrosion resistant glass • All slides have ground and polished edges to prevent injury to fingers • Superfrost and Colorfrost slides have a permanent opaque frosted area which makes written information permanent and easier to read • Pre-cleaned • Individually selected • Annealed to minimise chipping and breakage • Thin, flat and resistant to corrosion or fogging Microscope Slides Item Code Type Dimensions mm Pack Size Unit LBS2950RC Plain 75x25mm 100pcs Each LBS2951RC Frosted 75x25mm 100pcs Each LBS4951 Superfrost white 75x25mm 100pcs Each/Case of 35 LBS6951 Colorfrost green 75x25mm 100pcs Each/Case of 35 LBS7951 Colorfrost pink 75x25mm 100pcs Each/Case of 35 LBS8951 Colorfrost yellow 75x25mm 100pcs Each/Case of 35 LBSP4981 Polysine frosted 75x25mm 72pcs Each LBS4951PLUS Superfrost plus 75x25mm 72pcs Each General Glassware >> Stirring Rods, Miscellaneous & Microscope Slides LabServ Microscope Slides 55 LabServ Coverslips Item Code Type Dimensions mm Pack Size Unit LBS18X18-1 Coverslip No 1 18x18mm 242pcs Each/Case of 10 LBS22X22-1 Coverslip No 1 22x22mm 162pcs Each/Case of 10 LBS22X30-1 Coverslip No 1 22x30mm 119pcs Each/Case of 10 LBS22X40-1 Coverslip No 1 22x40mm 89pcs Each/Case of 10 LBS22X50-1 Coverslip No 1 22x50mm 62pcs Each/Case of 10 LBS22X60-1 Coverslip No 1 22x60mm 59pcs Each/Case of 10 LBS24X50-1 Coverslip No 1 24x50mm 65pcs Each/Case of 10 Laboratory Glassware Catalogue 2012/13 General Glassware General Glassware 56 * denotes products not stocked Culture Tubes 58 Closures62 Centrifuge Tubes 63 Specimen Tubes 64 Durham Tubes 65 Haematocrit Tubes 65 NMR Tubes 66 test,culture & specialty tubes Test, Culture & Specialty Tubes Test, Culture & Specialty Tubes Disposable Culture Tubes The LabServ borosilicate rimless disposable culture tubes have a low thermal expansion coefficient and high chemical resistance, making them ideal for use in the medical, pharmaceutical and analytical industries. The LabServ borosilicate rimless disposable culture tubes conform to USP, Type I and ASTM Type I, Class B standards and are available in a wide range of sizes from 6x50mm to 25x150mm. LabServ Disposable Culture Tubes, Borosilicate Glass, Rimless Laboratory Glassware Catalogue 2012/13 Item Code 58 Diameter x Height Pack Size Unit LBSDCT650 6x50mm 500pcs Each/Case of 8 LBSDCT1075 10x75mm 250pcs Each/Case of 6 LBSDCT1275 12x75mm 250pcs Each/Case of 6 LBSDCT13100 13x100mm 250pcs Each/Case of 6 LBSDCT16100 16x100mm 250pcs Each/Case of 4 LBSDCT16125 16x125mm 250pcs Each/Case of 4 LBSDCT16150 16x150mm 250pcs Each/Case of 4 LBSDCT18150 18x150mm 125pcs Each/Case of 4 LBSDCT20150 * 20x150mm 125pcs Case of 4 LBSDCT25150 * 25x150mm 50pcs Case of 6 Available in Australia Only Borosilicate glass KIMAX-51 composition assures the best all-around chemical durability of commercial glasses now available for laboratory ware. Complies with ASTM Specification E438, Type I, Class B glass requirements. KIMAX-51 has excellent chemical resistance against sodium leaching - a factor common in soda lime glass products. These are premium quality tubes with sturdy, uniform bottoms and consistent lengths. The 10 and 12 x 75 mm sizes are suitable for cell washing procedures. Tubes are packed in convenient trays for ease of use on bench tops and in drawers. The 10 and 12 x 75 mm sizes fit into Kimble 73510 stainless steel dispensers. The 6 x 50 mm size is often referred to as a “Durham tube”. Trays are shrink wrapped in plastic film with tubes remaining in constant alignment for protection against in-transit breakage and contamination. Designed from ASTM Specification E890. * denotes products not stocked Item Code Diameter x Height Pack Size Unit CSE73500-650 6x50mm 1000pcs Each CSE73500-1075 10x75mm 1000pcs Each CSE73500-1275 12x75mm 1000pcs Each CSE73500-13100 13x100mm 1000pcs Each CSE73500-16100 16x100mm 1000pcs Each CSE73500-16125 16x125mm 1000pcs Each CSE73500-16150 16x150mm 1000pcs Each CSE73500-18150 18x150mm 500pcs Each CSE73500-20150 * 20x150mm 500pcs Each CSE73500-25150 25x150mm 500pcs Each Available in Australia Only Kimble Chase Disposable Culture Tubes, Borosilicate Glass, Rimless Item Code Diameter x Height Pack Size Unit KIM73500-650 6x50mm 500pcs Case of 2 KIM73500-1075 10x75mm 250pcs Each/Case of 4 KIM73500-1275 12x75mm 250pcs Each/Case of 4 KIM73500-13100 13x100mm 250pcs Each/Case of 4 KIM73500-16100 16x100mm 250pcs Each/Case of 4 KIM73500-16125 16x125mm 250pcs Each/Case of 4 KIM73500-16150 16x150mm 250pcs Case of 4 KIM73500-18150 18x150mm 125pcs Each/Case of 4 KIM73500-18150 18x150mm 125pcs Each/Case of 4 KIM73500-20150 20x150mm 125pcs Case of 4 KIM73500-25150 25x150mm 125pcs Case of 4 Test, Culture & Specially Tubes >> Disposable Culture Tubes Kimble Chase Disposable Culture Tubes, Borosilicate Glass, Rimless Available in New Zealand Only 59 Test, Culture & Specialty Tubes Test, Culture & Specialty Tubes Reusable Culture Tubes KIMAX culture tubes are made from KG-33 glass tubing, with fire-polished top rims and uniform wall thickness for maximum heat transfer and chemical resistance. Durable white ceramic enamel marking spot. Designed from ASTM Specification E982, Type IV requirements. Kimble Chase Reusable Culture Tubes, with Rim Laboratory Glassware Catalogue 2012/13 Item Code 60 Diameter x Height Overflow Capacity Pack Size Unit KIM45048-1075 * 10x75mm 4mL 72pcs Case of 10 KIM45048-1275 * 12x75mm 6mL 72pcs Case of 10 KIM45048-13100 13x100mm 10mL 72pcs Case of 10 KIM45048-16100 * 16x100mm 15mL 72pcs Case of 8 KIM45048-16125 * 16x125mm 20mL 72pcs Case of 8 KIM45048-16150 16x150mm 24mL 72pcs Case of 8 KIM45048-18150 18x150mm 28mL 72pcs Case of 8 KIM45048-20150 * 20x150mm 36mL 72pcs Case of 4 KIM45048-25150 * 25x150mm 55mL 72pcs Case of 4 * denotes products not stocked Kimble Chase Reusable Culture Tubes, with PTFE-Faced Rubber Liner Threaded Cap Unattached Item Code Diameter x Height Overflow Capacity Pack Size Unit KIM45066A-13100 * 13x100mm 8mL 72pcs Case of 4 KIM45066A-16100 * 16x100mm 12mL 72pcs Case of 4 KIM45066A-16125 * 16x125mm 16mL 72pcs Case of 4 KIM45066A-16150 * 16x150mm 20mL 72pcs Case of 4 KIM45066A-20125 * 20x125mm 25mL 48pcs Case of 4 KIM45066A-20150 * 20x150mm 30mL 48pcs Case of 4 KIM45066A-25150 * 25x150mm 50mL 36pcs Case of 4 Test, Culture & Specially Tubes >> Reusable Culture Tubes KIMAX culture tubes are made from tubing with uniform wall thickness for maximum heat transfer and chemical resistance. Thread finish complies with Glass Packaging Institute (GPI) requirements. Cap has a PTFE-faced rubber liner and is not attached. Designed from ASTM E982, Type VI, Class B requirements. 61 Test, Culture & Specialty Tubes Test, Culture & Specialty Tubes Test Tube Closures Closures for culture tubes and flasks. Colour Coded - natural, red, green, yellow and blue available. Kimble Chase KIM-KAP, Polypropylene Laboratory Glassware Catalogue 2012/13 Item Code 62 Colour Diameter Pack Size Unit KIM73660-13 * Natural 13mm 500pcs Case of 2 KIM73660-16 * Natural 16mm 500pcs Case of 2 KIM73660-18 * Natural 18mm 500pcs Case of 2 KIM73660-20 * Natural 20mm 250pcs Case of 2 KIM73660-25 * Natural 25mm 250pcs Case of 2 KIM73660-38 * Natural 38mm 125pcs Case of 2 * denotes products not stocked Glassco Centrifuge Tubes, Conical Bottom, Graduated Item Code OD x height Capacity Pack Size Unit GLS088.202.01 * 13x100mm 5mL 50pcs Each GLS088.202.02 * 15x110mm 10mL 50pcs Each GLS088.202.03 * 17x120mm 15mL 50pcs Each GLS088.202.04 * 22x125mm 25mL 50pcs Each GLS088.202.05 * 28x125mm 50mL 50pcs Each Capacity Pack Size Unit Glassco Centrifuge Tubes, Conical Bottom, Plain Item Code OD x height GLS089.202.02 * 13x100mm 5mL 50pcs Each GLS089.202.03 * 15x110mm 10mL 50pcs Each GLS089.202.05 * 17x120mm 15mL 50pcs Each GLS089.202.06 * 22x125mm 25mL 50pcs Each GLS089.202.07 * 28x125mm 50mL 50pcs Each Capacity Pack Size Unit Glassco Centrifuge Tubes, Round Bottom, Graduated Item Code OD x height GLS094.202.01 * 16x110mm 12mL 50pcs Each GLS094.202.02 * 24x110mm 30mL 50pcs Each GLS094.202.03 * 28x110mm 40mL 50pcs Each GLS094.202.04 * 30x110mm 50mL 50pcs Each GLS094.202.05 * 45x110mm 100mL 50pcs Each GLS094.202.07 * 55x116mm 200mL 50pcs Each Test, Culture & Specially Tubes >> Test Tubes Closures & Centrifuge Tubes Centrifuge Tubes 63 Laboratory Glassware Catalogue 2012/13 Test, Culture & Specialty Tubes Test, Culture & Specialty Tubes 64 Specimen Tubes Samco Specimen Tubes, Soda Glass, Flat Bottom, with Polyethylene Push Cap Item Code Diameter x Height Wall Thickness Pack Size Unit SAMG050/17 * 10x38mm 0.6mm 250pcs Each SAMG050/18 * 10x50mm 0.6mm 250pcs Each SAMG050/19 * 12x38mm 0.85mm 100pcs Each SAMG050/20 12x50mm 0.85mm 100pcs Each SAMG050/22 * 12x75mm 0.85mm 100pcs Each SAMG050/24 16x50mm 0.85mm 100pcs Each SAMG050/25 * 16x75mm 0.85mm 100pcs Each SAMG050/26 19x50mm 0.85mm 100pcs Each SAMG050/27 * 19x75mm 0.85mm 100pcs Each SAMG050/28 25x50mm 0.85mm 100pcs Each SAMG050/29 * 25x75mm 0.85mm 100pcs Each SAMG050/30 * 25x100mm 0.85mm 100pcs Each SAMG050/31 * 25x150mm 0.85mm 100pcs Each * denotes products not stocked Samco neutral glass test tubes will withstand moderate temperature change. Samco Durham Tubes, Neutral Glass Item Code Diameter x Height Wall Thickness Pack Size Unit SAMG010/21 6.5x25mm 0.65mm 250pcs Each SAMG010/22 * 6.5x30mm 0.65mm 250pcs Each SAMG010/23 * 7.5x35mm 0.65mm 250pcs Each SAMG010/24 * 7.5x50mm 0.65mm 250pcs Each Haematocrit Tubes Test, Culture & Specially Tubes >> Specimen Tubes & More Durham Tubes Kimble Chase brand micro-haematocrit tubes are manufactured from soda lime glass, packed in plastic vials with reclosable snap-lock caps to maintain cleanliness. Ends may be sealed by flame, sealing clay or patented caps. They are available in borosilicate glass as a special order. Heparinised capillary tubes are treated to prevent blood clotting. Ammonium Heparin does not interfere with sodium identification. Kimble Chase Haematocrit Tubes Item Code Type Width (mm) Pack Size Unit CSE2501 Heparin 75 200pcs Each/Case of 12 CSE2502 Plain 75 200pcs Each/Case of 12 65 Test, Culture & Specialty Tubes Test, Culture & Specialty Tubes NMR Tubes Kontes thrift tubes are manufactured from KIMAX® N-51A borosilicate glass and their performance is assured by state of the art manufacturing and inspection processes for camber and concentricity. Caps attached. Kontes NMR Tubes, Thrift Quality, 5mm, N-51A Borosilicate Glass, Caps Attached Laboratory Glassware Catalogue 2012/13 Item Code 66 Approx. Frequency (MHz) Length (in) Wall Thickness Pack Size Unit KON897150-0007 * 500 7 0.38mm 5pcs Each KON897150-0008 * 500 8 0.38mm 5pcs Each KON897140-0007 * 400 7 0.38mm 5pcs Each KON897140-0008 * 400 8 0.38mm 5pcs Each KON897130-0007 * 300 7 0.38mm 5pcs Each KON897130-0008 * 300 8 0.38mm 5pcs Each KON897120-0007 * 200 7 0.38mm 5pcs Each KON897110-0007 * >200 7 0.38mm 5pcs Each KON897110-0008 * >200 8 0.38mm 5pcs Each * denotes products not stocked Flasks68 Stoppers74 Adapters75 interchangeable glassware Interchangeable Glassware Interchangeable Glassware Flasks Glassco flasks are manufactured from ASTM 438 Type 1 Class BORO 3.3 heat resistant glass. All come with thick uniform wall thickness and are printed with white enamel. All flasks comply to their respective DIN/ISO/ASTM and USP standards. Laboratory Glassware Catalogue 2012/13 Glassco Round Bottom Flasks, Single Neck 68 Item Code Capacity Socket Size Approx. Overall Height Diameter Pack Size Unit GLS057.202.05 25mL 14/23 65mm 33mm Each Case of 10 GLS057.202.06 25mL 19/26 85mm 41mm Each Case of 10 GLS057.202.08 50mL 14/23 90mm 51mm Each Case of 10 GLS057.202.09 50mL 19/26 90mm 51mm Each Case of 10 GLS057.202.10 50mL 24/29 115mm 51mm Each Case of 10 GLS057.202.11 100mL 14/23 105mm 64mm Each Case of 10 GLS057.202.12 100mL 19/26 105mm 64mm Each Case of 10 GLS057.202.13 100mL 24/29 105mm 64mm Each Case of 10 GLS057.202.20 250mL 14/23 140mm 85mm Each Case of 10 GLS057.202.21 250mL 19/26 140mm 85mm Each Case of 10 GLS057.202.22 250mL 24/29 140mm 85mm Each Case of 10 GLS057.202.25 500mL 19/26 163mm 105mm Each Case of 10 GLS057.202.30 1,000mL 24/29 200mm 131mm Each Case of 10 * denotes products not stocked Item Code Capacity GLS059.202.01 * 50mL GLS059.202.02 * 50mL GLS059.202.03 100mL Centre Socket Size Side Socket Size Pack Size Unit 24/29 14/23 Each Each 29/32 14/23 Each Each 24/29 14/23 Each Each GLS059.202.04 100mL 24/29 19/26 Each Each GLS059.202.05 * 100mL 29/32 14/23 Each Each GLS059.202.06 250mL 24/29 14/23 Each Each GLS059.202.07 250mL 24/29 19/26 Each Each GLS059.202.08 * 250mL 29/32 14/23 Each Each GLS059.202.09 * 500mL 24/29 14/23 Each Each GLS059.202.10 * 500mL 24/29 19/26 Each Each GLS059.202.11 * 500mL 29/32 14/23 Each Each GLS059.202.12 * 1,000mL 24/29 14/23 Each Each GLS059.202.13 * 1,000mL 24/29 19/26 Each Each GLS059.202.14 * 1,000mL 29/32 14/23 Each Each GLS059.202.15 * 2,000mL 34/35 19/26 Each Each Interchangeable Glassware >> Flasks Glassco Round Bottom Flasks, Two Necks 69 Laboratory Glassware Catalogue 2012/13 Interchangeable Glassware Interchangeable Glassware 70 Glassco Round Bottom Flasks, Three Necks, Angular Item Code Capacity Centre Socket Size Side Socket Size Pack Size Unit GLS060.202.01 * 100mL 19/26 14/23 Each Each GLS060.202.02 * 100mL 24/29 14/23 Each Each GLS060.202.03 * 100mL 24/29 19/26 Each Each GLS060.201.03A * 100mL 29/32 14/23 Each Each GLS060.202.04 * 250mL 19/26 19/26 Each Each GLS060.202.05 250mL 24/29 14/23 Each Each GLS060.202.06 * 250mL 24/29 19/26 Each Each GLS060.202.07 * 250mL 29/32 14/23 Each Each GLS060.202.08 * 250mL 29/32 19/26 Each Each GLS060.201.08A * 250mL 29/32 29/32 Each Each GLS060.202.09 * 500mL 24/29 14/23 Each Each GLS060.202.10 * 500mL 24/29 19/26 Each Each GLS060.202.11 * 500mL 29/32 14/23 Each Each GLS060.202.12 * 500mL 29/32 19/26 Each Each GLS060.201.12A * 500mL 29/32 29/32 Each Each GLS060.202.13 * 1,000mL 24/29 14/23 Each Each GLS060.202.14 * 1,000mL 24/29 19/26 Each Each GLS060.202.15 * 1,000mL 29/32 14/23 Each Each GLS060.202.16 * 1,000mL 29/32 19/26 Each Each GLS060.202.17 * 1,000mL 29/32 29/32 Each Each GLS060.202.18 * 2,000mL 24/29 19/26 Each Each GLS060.202.19 * 2,000mL 29/32 24/29 Each Each GLS060.202.20 * 2,000mL 29/32 29/32 Each Each * denotes products not stocked Item Code Capacity Socket Size Approx. Diameter Approx. Overall Height Pack Size Unit GLS062.202.06 * 25mL 14/23 38mm 90mm Each Case of 10 GLS062.202.07 * 50mL 14/23 48mm 110mm Each Case of 10 GLS062.202.09 * 100mL 14/23 58mm 125mm Each Case of 10 Centre Socket Size Side Socket Size Approx. Overall Height Pack Size Unit Pear Shaped Flasks, Two Necks Item Code Capacity GLS063.202.01 * 50mL 14/23 14/23 110mm Each Each GLS063.202.02 * 100mL 14/23 14/23 125mm Each Each Volumetric Glassware >> Flasks Pear Shaped Flasks, Single Neck Evaporating Flasks Item Code Capacity Socket Size Approx. Overall Height Pack Size Unit GLS069.202.01 * 50mL 29/32 94mm Each Case of 10 GLS069.202.02 * 100mL 24/29 110mm Each Case of 10 GLS069.202.03 * 100mL 29/32 110mm Each Case of 10 GLS069.202.04 * 250mL 24/29 140mm Each Case of 10 GLS069.202.05 * 250mL 29/32 140mm Each Case of 10 GLS069.202.06 * 500mL 24/29 170mm Each Case of 10 GLS069.202.07 * 500mL 29/32 170mm Each Case of 10 GLS069.202.08 * 1,000mL 24/29 210mm Each Case of 10 GLS069.202.09 * 1,000mL 29/32 210mm Each Case of 10 GLS069.202.10 * 2,000mL 29/32 250mm Each Case of 6 71 Kjeldahl Flasks Item Code Capacity Socket Size Approx. Height Pack Size Unit GLS070.202.01 * 50mL 19/26 162mm Each Case of 2 GLS070.202.02 * 100mL 19/26 162mm Each Case of 2 GLS070.202.03 * 100mL 24/29 265mm Each Case of 2 GLS070.202.04 * 300mL 24/29 295mm Each Case of 2 GLS070.202.05 * 500mL 24/29 305mm Each Case of 2 GLS070.202.06 * 800mL 24/29 325mm Each Each Laboratory Glassware Catalogue 2012/13 Interchangeable Glassware Interchangeable Glassware 72 * denotes products not stocked Item Code Capacity Socket Size Approx. Overall Diameter Approx. Overall Height Pack Size Unit GLS071.202.06 * 25mL 14/23 75mm 42mm Each Case of 10 GLS071.202.07 * 25mL 19/26 75mm 42mm Each Case of 10 GLS071.202.08 * 50mL 14/23 85mm 51mm Each Case of 10 GLS071.202.09 50mL 19/26 85mm 51mm Each Case of 10 GLS071.202.10 50mL 24/29 85mm 64mm Each Case of 10 GLS071.202.11 * 100mL 14/23 105mm 64mm Each Case of 10 GLS071.202.12 100mL 19/26 105mm 64mm Each Case of 10 GLS071.202.13 100mL 24/29 105mm 64mm Each Case of 10 GLS071.202.14 * 100mL 29/32 105mm 64mm Each Case of 10 GLS071.202.15 * 150mL 19/26 118mm 74mm Each Case of 10 GLS071.202.16 * 150mL 24/29 118mm 74mm Each Case of 10 GLS071.202.17 * 150mL 29/32 118mm 74mm Each Case of 10 GLS071.202.18 * 250mL 19/26 140mm 85mm Each Case of 10 GLS071.202.19 * 250mL 24/29 140mm 85mm Each Case of 10 GLS071.202.20 * 250mL 29/32 140mm 85mm Each Case of 10 GLS071.202.22 * 500mL 19/26 175mm 105mm Each Case of 10 GLS071.202.22A * 500mL 24/29 175mm 105mm Each Case of 10 GLS071.202.23 * 500mL 29/32 175mm 105mm Each Case of 10 GLS071.202.25 * 1,000mL 24/29 220mm 131mm Each Case of 10 GLS071.202.26 * 1,000mL 29/32 220mm 131mm Each Case of 10 GLS071.202.27 * 1,000mL 34/35 220mm 131mm Each Case of 10 GLS071.202.28 * 2,000mL 29/32 280mm 166mm Each Case of 6 GLS071.202.29 * 2,000mL 34/35 280mm 166mm Each Case of 6 Volumetric Glassware >> Flasks Conical Flasks 73 Stoppers Glassco Stoppers, Hollow, Flat Bottom Item Code Socket Size Shape Pack Size Unit GLS011.202.01 * 10/19 Hexagonal Each Case of 100 GLS011.202.02 * 12/21 Hexagonal Each Case of 100 GLS011.202.02A 14/23 Hexagonal Each Case of 100 GLS011.202.03 19/26 Hexagonal Each Case of 100 GLS011.202.04 24/29 Hexagonal Each Case of 100 GLS011.202.05 29/32 Hexagonal Each Case of 100 GLS011.202.06 34/35 Hexagonal Each Case of 100 Laboratory Glassware Catalogue 2012/13 Interchangeable Glassware Interchangeable Glassware 74 * denotes products not stocked Glassco interchangeable glassware is manufactured from ASTM E-438 Class A BORO 3.3 glass. All joints are first made on semi automatic machines and are then ground with diamond tools for better taper and precision, and then polished to give better finish. All the joints go through strict checks on high vacuum machines for leak check. The different kinds of adapters are then prepared by skilled glassblowers as per the respective standards. Glassco Reduction Adapters Item Code GLS013.202.01 Socket Size Cone Size Pack Size Unit * 14/23 14/23 Each Case of 10 GLS013.202.01A 14/23 19/26 Each Case of 10 GLS013.202.02 14/23 24/29 Each Case of 10 GLS013.202.03 14/23 29/32 Each Case of 10 GLS013.202.04 19/26 24/29 Each Case of 10 GLS013.202.05 19/26 29/32 Each Case of 10 GLS013.202.06 19/26 34/35 Each Case of 10 GLS013.202.07 * 19/26 40/38 Each Case of 10 GLS013.202.08 * 19/26 45/40 Each Case of 10 GLS013.202.09 * 19/26 55/44 Each Case of 10 GLS013.202.10 24/29 29/32 Each Case of 10 GLS013.202.11 24/29 34/35 Each Case of 10 GLS013.202.12 * 24/29 40/38 Each Case of 10 GLS013.202.13 * 24/29 45/40 Each Case of 10 GLS013.202.14 24/29 50/42 Each Case of 10 GLS013.202.15 * 24/29 55/44 Each Case of 10 GLS013.202.16 29/32 34/35 Each Case of 10 GLS013.202.17 * 29/32 40/38 Each Case of 10 GLS013.202.18 * 29/32 45/40 Each Case of 10 GLS013.202.19 * 34/35 40/38 Each Case of 10 GLS013.202.20 * 34/35 45/40 Each Case of 10 GLS013.202.21 * 34/35 50/42 Each Case of 10 Volumetric Glassware >> Stppers & Adapters Adapters 75 Laboratory Glassware Catalogue 2012/13 Interchangeable Glassware Interchangeable Glassware 76 Glassco Expansion Adapters Item Code Socket Size Cone Size Pack Size Unit GLS014.202.01 19/26 14/23 Each Case of 10 GLS014.202.02 24/29 14/23 Each Case of 10 GLS014.202.03 24/29 19/26 Each Case of 10 GLS014.202.03A 29/32 14/23 Each Case of 10 GLS014.202.04 29/32 19/26 Each Case of 10 GLS014.202.05 29/32 24/29 Each Case of 10 GLS014.202.06 * 34/35 19/26 Each Case of 10 GLS014.202.07 * 34/35 24/29 Each Case of 10 GLS014.202.08 * 34/35 29/32 Each Case of 10 GLS014.202.09 * 40/38 24/29 Each Case of 10 GLS014.202.10 * 45/40 29/32 Each Case of 10 Glassco Swan Neck Adapters, with Screw Thread to Accept Thermometers, etc. Item Code Socket Size Cone Size Pack Size Unit GLS018.202.01 * 14/23 19/26 Each Each GLS018.202.01A * 19/26 19/26 Each Each GLS018.202.02 * 19/26 24/29 Each Each GLS018.202.03 * 24/29 24/29 Each Each GLS018.202.04 * 29/32 29/32 Each Each * denotes products not stocked Item Code Socket Size Approx. Length Pack Size Unit GLS019.202.01 * 14/23 65mm Each Case of 10 GLS019.202.02 * 19/26 65mm Each Case of 10 GLS019.202.03 * 24/29 65mm Each Case of 10 GLS019.202.04 * 29/32 65mm Each Case of 10 Approx. Length Pack Size Unit Glassco Long Stem Adapters Item Code Socket Size GLS019.202.05 * 14/23 190mm Each Case of 10 GLS019.202.06 * 19/26 200mm Each Case of 10 GLS019.202.07 * 24/29 200mm Each Case of 10 GLS019.202.08 * 29/32 200mm Each Case of 10 Volumetric Glassware >> Adapters Glassco Short Stem Adapters Glassco Straight Receiver Adapters Item Code Socket Size Pack Size Unit GLS020.202.01 * 14/23 Each Case of 10 GLS020.202.02 * 19/26 Each Case of 10 GLS020.202.03 * 24/29 Each Case of 10 GLS020.202.04 * 29/32 Each Case of 10 77 Interchangeable Glassware Interchangeable Glassware Glassco Bend Adapters, with Vacuum Connection and Screw Thread Adapter Item Code Socket Size Cone Size Pack Size Unit GLS022.201.01 * 14/23 14/23 Each Each GLS022.201.02 * 14/23 19/26 Each Each GLS022.201.03 * 19/26 19/26 Each Each GLS022.201.04 * 19/26 24/29 Each Each GLS022.201.05 * 24/29 24/29 Each Each GLS022.201.06 * 24/29 29/32 Each Each GLS022.201.07 * 29/32 29/32 Each Each Glassco Straight Adapters, with Vacuum Connection and Screw Thread Adapter Laboratory Glassware Catalogue 2012/13 Item Code Cone Size Pack Size Unit GLS022.202.01 * 14/23 14/23 Each Each GLS022.202.02 * 14/23 19/26 Each Each GLS022.202.02A * 19/26 19/26 Each Each GLS022.202.03 * 19/26 24/29 Each Each GLS022.202.04 * 24/29 24/29 Each Each GLS022.202.05 * 24/29 29/32 Each Each GLS022.202.06 * 29/32 29/32 Each Each Glassco Receiver Adapters, with Multiple Connections and Screw Thread Item Code 78 Socket Size Socket Size Cone Size Pack Size Unit GLS024.202.01 * 14/23 14/23 Each Each GLS024.202.02 * 14/23 19/26 Each Each GLS024.202.03 * 19/26 19/26 Each Each * denotes products not stocked Item Code Socket Size Cone Size Pack Size Unit GLS025.202.00 * 14/23 14/23 Each Each GLS025.202.0A * 14/23 19/26 Each Each GLS025.202.01 * 19/26 19/26 Each Each GLS025.202.02 * 19/26 24/29 Each Each GLS025.202.03 * 24/29 24/29 Each Each GLS025.202.04 * 29/32 29/32 Each Each Cone Size to Fit Condenser Pack Size Unit Glassco Recovery Bends, with Sloping Socket Item Code Cone Size to Fit Flask GLS026.202.01 * 14/23 14/23 Each Each GLS026.202.02 * 24/29 14/23 Each Each GLS026.202.03 * 19/26 19/26 Each Each GLS026.202.04 * 24/29 19/26 Each Each GLS026.202.05 * 29/32 19/26 Each Each GLS026.202.06 * 29/32 29/32 Each Each GLS026.202.07 * 24/29 24/29 Each Each GLS026.202.08 * 34/35 24/29 Each Each GLS026.202.09 * 29/32 24/29 Each Each GLS026.202.10 * 34/35 34/35 Each Each Volumetric Glassware >> Adapters Glassco Plain Bend Receiver Adapters 79 Interchangeable Glassware Interchangeable Glassware Glassco Recovery Bends, Vertical Item Code Cone Size to Fit Flask Cone Size to Fit Condenser Pack Size Unit GLS027.202.01 * 14/23 14/23 Each Each GLS027.202.02 * 19/26 19/26 Each Each GLS027.202.03 * 24/29 24/29 Each Each GLS027.202.04 * 24/29 24/29 Each Each GLS027.202.05 * 29/32 29/32 Each Each Cone Size Pack Size Unit Glassco Splash Heads, Vertical Laboratory Glassware Catalogue 2012/13 Item Code 80 Socket Size GLS030.202.01 * 14/23 14/23 Each Each GLS030.202.02 * 19/26 24/29 Each Each GLS030.202.03 * 29/32 29/32 Each Each Cone Size Pack Size Unit Glassco Splash Heads, Vertical, Pear Shaped Item Code Socket Size GLS031.202.01 * 14/23 14/23 Each Each GLS031.202.02 * 19/26 19/26 Each Each GLS031.202.03 * 24/29 19/26 Each Each GLS031.202.04 * 24/29 24/29 Each Each GLS031.202.05 * 29/32 19/32 Each Each * denotes products not stocked Item Code Socket Size Cone Size Pack Size Unit GLS032.202.01 * 14/23 14/23 Each Each GLS032.202.02 * 19/26 19/26 Each Each GLS032.202.03 * 24/29 19/26 Each Each GLS032.202.04 * 24/29 24/29 Each Each GLS032.202.05 * 29/32 29/32 Each Each Glassco Adapter Cones, with Stem to Rubber Tubing, Right Angle Connection Item Code Cone Size Pack Size Unit GLS036.202.01 14/23 Each Each GLS036.202.02 19/26 Each Each GLS036.202.03 24/29 Each Each GLS036.202.04 * 29/32 Each Each Volumetric Glassware >> Adapters Glassco Splash Heads, Sloping, Pear Shaped Glassco Adapter Sockets to Rubber Tubing, with Screw Thread Item Code GLS038.202.01 Cone Size * 14/23 Pack Size Unit Each Each GLS038.202.02 * 19/26 Each Each GLS038.202.03 * 24/29 Each Each GLS038.202.04 * 29/32 Each Each 81 Glassco Socket to Cone Adapters, with Side Arm and Screw Thread Item Code Socket Size Cone Size Pack Size Unit GLS039.202.01 * 14/23 14/23 Each Each GLS039.202.02 * 14/23 19/26 Each Each GLS039.202.03 * 14/23 24/29 Each Each GLS039.202.04 * 14/23 29/32 Each Each GLS039.202.05 * 19/26 19/26 Each Each GLS039.202.06 * 19/26 24/29 Each Each GLS039.202.07 * 19/26 29/32 Each Each GLS039.202.08 * 24/29 24/29 Each Each GLS039.202.09 * 24/29 29/32 Each Each GLS039.202.10 * 29/32 29/32 Each Each Laboratory Glassware Catalogue 2012/13 Interchangeable Glassware Interchangeable Glassware 82 * denotes products not stocked Baskets84 Drying Racks 84 Pipette Teats 84 Bench Protectors 85 Detergents85 Water Stills 86 related products Related Products Related Products Baskets Met-App Test Tube Baskets, Autoclavable Item Code Type Dimensions (mm) Pack Size Unit MET4015-150 * White nylon coated 150x150x150 Each Each MET4015-200 * White nylon coated 200x200x200 Each Each MET4017-150 * Stainless steel 150x150x150 Each Each MET4017-200 * Stainless steel 200x200x200 Each Each Drying Racks Laboratory Glassware Catalogue 2012/13 Met-App Drying Racks, Autoclavable, White Nylon Coated Item Code Mount Dimensions (mm) Pack Size Unit MET4050 Wall mounted 570x600 Each Each MET4055 * Bench mounted 360x500 Each Each Pipette Teats LabServ Rubber Teats, for use with Pasteur Pipettes and Glass Droppers 84 Item Code Colour Pack Size Unit LBS444260 Red 10pcs Each * denotes products not stocked Related Products >> Sub-Section Bench Protectors Benchkote™ is an absorbent, impermeable material designed to protect laboratory surfaces against hazardous spills. The material features a high-quality, smooth, absorbent Whatman paper which quickly absorbs liquid spills, and a laminated polyethylene layer that prevents flow-through to the working surface. After use the sheet is incinerated or disposed of according to local regulations. Whatman Benchkote™ Item Code Type Dimensions Pack Size Unit WHA2300-916 Sheets 460x570mm 50pcs Each WHA2300-599 * Pad 460x570mm 50pcs Each WHA2300-731 Reel 460mmx50m Each Each WHA2300-772 * Reel 920mmx50m Each Each Type Size Pack Size Unit Decon 90 liquid concentrate Detergents Decon Detergents Item Code DEC90-5L 5L Each Case of 4 DECACIDRINSE * Acid rinse liquid 5L Each Each DECDECMATIC-5L * Decomatic liquid 5L Case of 4 Case of 4 Each Case of 4 DECDRI-DECN-5KG Dri-decon granular concentrate 5kg 85 Related Products Related Products Water Stills • The Merit is the ideal choice for budget conscious laboratories that can’t afford to compromise on quality • It combines economy and high performance with a host of other features which comparable stills cannot match • Glass construction with long life metal heating element • Two independent safety thermostats • Wall mountable • Output: 4 litres/hour, single distilled Laboratory Glassware Catalogue 2012/13 Stuart Merit Water Still Item Code Type Pack Size Unit BIBW4000 Water Still Merit Each Each Available in New Zealand Only The metal still cases are attractively finished in a durable powder coating. Each still maybe wall, shelf or bench mounted. The still monitors the water level in any reservoir to which you connect it, and controls the operation of the still, turning it on and off as the water level changes in the reservoir. Together with over-temperature and feed water supply failure protection, this allows 24-hour unattended operation of all stills. Labglass Water Stills Item Code Type Output Feed Pack Size Unit LABRG1 * Cascade 3L/hr Single Each Each LABRG2 * Cascade 3L/hr Dual Each Each LABRG3 * Delta 3-6L/hr Single Each Each Available in Australia Only 86 * denotes products not stocked technical data Technical Data Technical Data Glassco NABL Accreditation Glassco’s Calibration Laboratory has undertaken accreditation for its system for calibration and testing as per ISO 17025:2005. Results of calibration are guaranteed for precision as per the DIN, ISO, USP & ASTM standards. Glassco’s Calibration Laboratory is NABL approved. NABL has an MRA under the Asia Pacific Laboratory Accreditation Cooperation (APLAC) and the International Laboratory Accreditation Cooperation (ILAC), which means the calibration provided to customers for volumetric ware is acceptable in calibration laboratories worldwide. The calibrations performed by Glassco calibration laboratory are conducted under ISO 17025:2005. Laboratory Glassware Catalogue 2012/13 Care and Use — Cleaning Methods Care should be exercised when using most cleaning solutions as they can cause skin irritations or severe burns on contact. Dilute solutions become concentrated as the water evaporates; therefore, always flush the exposed area immediately with large quantities of water. NOTE: If wiping or other mechanical cleaning action is necessary, it should be done gently using non-abrasive cleaners and wiping materials. The use of abrasive materials will damage the glass surface, degrading its inherent strength. The list of methods given here is by no means complete, but offers a fairly wide variety and should cover all the usual contaminants, as well as the more important special cases. There are some specific contaminants that may require specialised cleaning methods, and some are given here: 1. Permanganate stains. Use a mixture of equal volume of 3% sulfuric acid and 3% hydrogen peroxide. 2. Iron stains. Use a solution containing one part hydrochloric acid and one part water. 3. Bacteriological material. Glassware should be soaked in a suitable disinfectant solution or steam autoclaved followed by cleaning with a suitable agent. It is frequently desirable to give glassware a preliminary rinse or soak with an organic solvent to remove grease, followed by a water rinse. The rinsing with water must be done thoroughly if acid will be used later to clean the glassware. Unless autoclaving is necessary, glassware should be cleaned as soon as possible after use to avoid setting and caking of residues. Pipettes, for example, may be placed in a convenient jar containing a weak antiseptic solution immediately after use. Autoclaving is necessary to disinfect glassware that may have been used to contain potentially dangerous biological fluids. There is a wide variety of cleaning agents available that will remove surface contaminants such as silicone and other organic and biological residues that may interfere with trace analyses. These cleaners are available in biodegradable, phosphate-free and chromium-free formulations if desired, and can be obtained from Thermo Fisher Scientific. 88 CAUTIONS: Before using any cleaning solution, refer to its Material Safety Data Sheet for precautions to be observed during use. Some of the cleaning materials used may leave trace residue unless the rinsing process is carried out thoroughly. While such traces may not be harmful if the object of cleaning is to prepare the glassware for calibration, they can give trouble in certain laboratory operations. When glassware is to be calibrated, the final rinsings must be performed with distilled water. If an article is to be dried after cleaning, as is necessary for all vessels marked “To Contain”, ethyl alcohol or acetone (American Chemical Society Specification) may be used. Drying may be hastened by blowing clean, dry air into the vessel (or sucking the air through the vessel). Efficient air filters must be provided to remove any particles. You play by common, ordinary, everyday rules, the kinds of things you’d do naturally if you just took time to think about them: 1. Don’t get cut – it hurts you and your productivity. 2. Don’t drop glassware – avoid the bruises that lead to breakage. 3. Don’t use chipped or broken glassware – it’s dangerous and breaks more readily. 4. Don’t mouth pipette – you could inhale a toxic substance, burn your mouth, or cut your lip. 5. Don’t leave pipettes sticking out of beakers or flasks – an invitation for an accident. 6. Insert tubing carefully. Use a protective towel for your hand and lubricate the tubing. 7. Dispose of broken glassware in a special receptacle. 8. Carry large containers carefully, using a bottle carrier. 9. Clean and rinse glassware very well with deionised water, then let it drain dry on a clean, lint-free towel. To back up the rules, you need a formal laboratory safety program. It begins with a written safety policy, a safety committee, and regular safety inspections. That way, you can investigate accidents thoroughly, keep a record and analysis of them, and promote safety awareness all the time. It could lead you to the best safety record ever. Technical Data >> Glassware Glassware Safety Care and Use — Cleanliness of Apparatus The usual criterion of cleanliness of glass apparatus is uniform wetting of the surface by distilled water. Certain contaminants, especially grease, adhering to the walls prevent them from being uniformly wetted, and there is a tendency for water to collect into drops. Imperfect wetting causes irregularities in capacity of volumetric glassware by distorting the meniscus, and also by affecting the volume of the residue adhering to the walls after emptying instruments calibrated to deliver the indicated volume. Even when the surface of the vessel is uniformly wetted, variations in the apparent capacity still may occur, due to contamination of the liquid surface by minute quantities of fatty or other organic substances which produce a change in surface tension affecting the shape of the meniscus. The cleaning, rinsing and drying, therefore, must be carried out in such a way as to prevent this from happening. The choice of the procedure to be used in cleaning glassware depends on the nature of the contaminant. In many cases special reagents or methods must be used to remove a particular substance. Before listing the more important methods, it is desirable to make a few general statements. Glass Glasses used in chemical apparatus have excellent resistance to acids, except hydrofluoric. Strong alkaline solutions, such as hot caustic solutions, will attack any glass if contact is prolonged. This is true even though a particular glass may not exhibit any visible effect, due to the solubility of the reaction products. Dilute detergent solutions, up to about 2% strength, will have no serious effect on the glass, unless the glass is exposed for unnecessarily long periods or the detergent is allowed to dry on the glass. Coloured Graduations The scales and inscriptions of many items of Kimble glassware are coloured by staining a thin layer of the glass. Since the coloured portion is of the same composition as the glass object, the resistance to chemical attack is the same as that of the rest of the glass. Here, the colour can be removed only by dissolving a layer of glass from the surface. Some Kimble volumetric glassware has fused on, ceramic enamel printed lines and inscriptions. These fused-on enamels are quite resistant to acids and alkalies. In most cases they should last as long as the piece of apparatus if cared for properly. However, by their nature, they cannot be as resistant as the ware to which they adhere. Consequently, the graduated lines should not be subjected to prolonged immersion in acids or alkalies. Whenever the lines are wetted by reagents, they should be rinsed as soon as conveniently possible. Safety Precautions With many pieces of glassware, it is necessary or desirable to fill by suction when cleaning. Do not suck up acid or other cleaners by mouth. In fact, do not pipette by mouth at all. Use hand held, manual or electronic pipetting aids 89 Technical Data Technical Data Abrasives Do not use abrasives on glassware, particularly volumetric ware. The surface will be marred in time, and the resultant scratches may prevent proper drainage or act as resting places for adulterants which will be difficult to remove. Water for Rinsing When preparing a piece of glassware for calibration, rinsing with tap water should be followed by a thorough rinsing with distilled water. Sufficient material may be deposited on the surface by tap water to cause erratic results, particularly with small items, even though water wets the surface uniformly. Even in ordinary cleaning processes, the use of deionised water is recommended. Adherent Organic Residues Never attempt to remove such residues by the application of direct heat. Permanent strains may be introduced and, what is more important, the calibration of volumetric apparatus may be changed. Care and Use — Ground-Glass Surfaces Laboratory Glassware Catalogue 2012/13 Ground-glass joints and stopcocks should never be used when dry. Although ground-glass surfaces seal well without the use of lubricants, it is advisable to lubricate them to prevent sticking and breakage. Ground surfaces must be cleaned prior to lubrication—dust, dirt and particulate 90 matter may score the surface and cause leakage. Different lubricants are used for these operating conditions: Silicone grease—for high temperature and high vacuum Glycerin—for long term reflux or extraction Hydrocarbon grease—for general laboratory use Lubricating Ground-Glass Joints 1. Lubricate joints that must be airtight and when glassware contains strong alkaline solutions. 2. Lubricate only the upper part of the inner joint. A properly lubricated joint appears clear, without striations. 3. Do not allow grease to come in contact with vapour or liquid and cause contamination. Lubricating Stopcocks Spread two circular bands of grease around the stopcock plug. Insert the plug into the barrel and twist several times until the assembly is completely transparent. Be careful not to use too much lubricant or the bore will become plugged. Recommendations for the Care and Use of Glassware A. TO AVOID SERIOUS AND PERSONAL INJURY, AVOID ABRASIONS An abrasion reduces the strength of glass, making it more susceptible to breakage under impact and/or thermal shock. Thermal shock may result from sudden changes in temperature or use on either a burner or hot plate. Serious injuries could result if breakage occurs while glass holds heated and/or corrosive liquid. B. RECOMMENDED GLASSWARE CLEANING AND HANDLING PROCEDURES Proper Cleaning Procedure 1. Washing machines may be used. Support racks on the washer must be well maintained. The support pins should be coated with a nonabrasive material to prevent metal to glass contact and scratching. 2. For manual washing, use only plastic core brushes that have soft nonabrasive bristles. Soft, clean sponges or other wiping materials may be used. DO NOT USE THESE BRUSHES OR WIPING MATERIALS WITH ABRASIVE CLEANERS. Keep them clean. Scotch Brite and similar scouring pads will scratch glass and should not be used. 3. Inspect glassware before each use and discard if scratched, chipped, cracked or damaged in any way. 4. Many commercial glass cleaners are available. Follow the manufacturer’s directions for the use of these products since some are corrosive and can damage the glass. 5. Organic solvents are acceptable cleaning agents when conditions warrant their use. possible injury. C. AVOID IMPACT Glass will break as a result of impact. Use care when handling to avoid impacting hard objects, such as spigots, other glassware, counter tops, etc. D. HEATING GLASSWARE 1. Use wire gauze when heating over open flame. 2. Use either low or medium heat settings when using a hot plate. High hot plate settings will cause excessive localised heating of the glassware and will eventually cause breakage and possible injury. 3. Do not heat glassware designated as heavy duty unless recommended by the manufacturer. Even though these items have added mechanical strength, they are more susceptible to breakage from thermal shock when heated. 4. Do not allow the contents of the container to boil dry as this may induce permanent stresses that will eventually cause breakage. Discard containers that have been boiled dry. DO NOT evacuate or pressurise unless recommended. E. CENTRIFUGE TUBES RCF values can be significantly reduced if the glass tubes have been scratched or otherwise physically abused resulting in surface damage and lowered glass strength. Technical Data >> Glassware Improper Cleaning Procedure: 1. Do not place metal or other hard objects, such as spatulas, glass stirring rods, or brushes with metal parts, inside the glassware. This will scratch the glass and cause eventual breakage and injury. 2. Do not use strong alkaline products and hydrofluoric acid as cleaning agents; they are glass dissolvers and can damage the glassware and eventually cause breakage which can result in injury. 3. Do not use any abrasive cleansers, including soft cleansers (i.e. Ajax, Comet, Old Dutch, Soft Scrub, etc.), as these will scratch the glass and cause eventual breakage and injury. 4. Do not place hands inside glassware while wearing any jewellery, particularly diamond rings, as these will score the inside of the glassware and eventually cause breakage and injury. 5. Do not heat glassware to temperatures (>426˚C) needed to burn out carbon residues. This will result in the introduction of permanent stresses in the glass that will eventually cause the glassware to break resulting in Recommendations for the Care and Use of NMR Tubes A. TO AVOID SERIOUS AND PERSONAL INJURY, AVOID ABRASIONS AND IMPACTS Abrasions reduce the strength of glass, making it more susceptible to breakage under impact and/or thermal shock. Thermal shock may result from sudden changes in temperature or use on either a burner or hot plate. Serious injuries could result if breakage occurs while glass holds heated and/or corrosive liquid. Glass will break as a result of impact. Use care when handling to avoid impacting hard objects, such as spigots, other glassware, counter tops, etc. B. RECOMMENDED GLASSWARE CLEANING AND HANDLING EQUIPMENT AND PROCEDURES Proper Cleaning Procedure 1. Kimble Chase offers several styles of NMR tube washers: KON897033-0003 5-place 3mm Tube Washer KON897033-0005 5-place 5mm Tube Washer KON897030-0005 Single-place 5mm Tube Washer KON459960-0000 Single-place 10mm Tube, Cuvette, and Cell Washer 2. Before use, rinse or clean the tube with distilled water and dry properly. 3. Empty and rinse reusable tubes as soon as possible after use. Always properly discard disposable NMR tubes as soon as possible after use. 4. Use of a fume hood is recommended when cleaning NMR tubes. Popular cleaning solutions include acetone, distilled water, and methanol or ethyl alcohol, as well as organic solvents. Difficult cleaning jobs may require the use of mineral acid or fuming nitric acid soaks. Final rinses of distilled water or acetone are recommended depending on the intended use. 5. After cleaning, properly dry by air or with a nitrogen gas stream. 6. Inspect tubes before each use and discard if scratched, chipped, cracked or damaged in any way. 7. Clean the outside of the tube in order to prevent introduction of dirt or impurities to the probe or the internal mechanisms of the NMR machine. 8. Always store NMR tubes in dry, particle free environments. Improper Cleaning Procedure and Use: 1. Never use chromic acid, or any caustic or alkaline solutions with an NMR tube. 2. Never dry tubes in an oven for more than 30 minutes at 125ºC. 3. Never store tubes in an oven. Excessive heat can cause warpage. 4. Never use any tube that does not roll evenly on flat surfaces, or exhibits any physical abnormality. 91 Laboratory Glassware Catalogue 2012/13 Technical Data Technical Data Care and Handling of Volumetric Glassware “To Contain ” versus “To Deliver” Proper use of calibrated volumetric glassware requires that the user be informed whether the ware is a “to contain” or “to deliver” vessel. All Kimble calibrated ware is marked either “TC” or “TD”. When the graduation line denotes the volume contained in the calibrated vessel, the ware is marked “TC”. When the graduation line indicates the volume delivered from the vessel, the ware is marked “TD”. When a vessel is calibrated “TD”, it differs from a “TC” calibrated vessel in that a drainage holdback error, the amount of water required to wet the inner surface of the vessel in contact with the water, is added to the “TC” volume. The “TD” vessel then delivers the same volume as contained in a “TC” vessel. Product descriptions in this catalog usually state the method of calibration used. (The International Standards Organization designation for “to contain” is “IN” and “to deliver”, is “EX”.) Pipettes Calibrated “To Deliver” (EX) The pipette is clamped in a vertical position and the 3-way stopcock connected to it with rubber tubing. The bent arm of the stopcock has a length of rubber hose attached which can be held in the mouth or connected to a vacuum line. Distilled water at the temperature of the room is placed in the large beaker. The water is stirred before use, care being taken not to introduce air into it. Before making a weighing, the pipette is filled one or more times from the beaker by applying suction through the stopcock, in order to bring the pipette to the temperature of the water. Finally the pipette is filled to about 10 mm above the mark, the stopcock closed, and the beaker removed. The stopcock now is opened to connect the pipette to the straight vertical tube and the water lowered slowly to the 0 line. During this emptying, the edge of the tip is kept in contact with the side of the beaker. The rate of descent of the water is controlled by a finger applied to the upper end of this tube. After setting to 0, the stopcock is closed. Then the temperature of the water in the large beaker is taken and this reading is used as the temperature of the water in the pipette. All deliveries should start at the 0 line. To start the delivery into the receiver the stopcock is opened fully, again connecting pipette and vertical tube. The plug is not touched after this, any control needed being exercised by the forefinger on the vertical tube. The same precautions are taken as for burettes against splashing of water and wetting the upper part of the neck of the receiver. 92 Where delivery of a measuring or serological pipette is very rapid, the forefinger must be held on the vertical tube from the start of delivery, but water is retarded as little as possible without losing control. For weighings of intermediate lines, water is allowed to empty until a few mm above the line. Then a finger on the vertical tube is used to slow up the delivery so that the water can be set accurately at the mark. The tip is kept in constant contact with the receiving vessel throughout the delivery. Then the receiver is withdrawn and the stopcock closed. When the pipette has an opaque ring or rings near the top, this indicates that the amount of water remaining in the tip after free delivery has ceased is to be blown out and added to the original delivery. A count of two seconds is made after free delivery has ended and while the neck and tip are still in contact, then air is blown through the rubber hose on the bent arm of the stopcock to eject the liquid in the tip. The neck of the bottle is removed from contact immediately after this. Give only one puff, strong enough to expel the liquid. The time of two seconds has been selected as being the average length of time required in actual service after free delivery has ceased to insert the top of the pipette in the mouth preparatory to blowing through. Pipettes Calibrated “To Contain” (IN) If the capacity is from a mark to the tip, the pipette should be weighed dry, filled with water to the mark and reweighed. To hold the pipette a saddle may be used on the balance pan. The pipette may be set up as explained previously and the filling and setting to the mark accomplished in the same way. Then, a rubber cap or a piece of rubber tubing closed by a short glass rod is slipped up over the tip and the pipette is removed from the stand and weighed. The first weighing of the dry pipette should include the rubber cap or rubber tubing. When the indicated volume is between marks, the pipette is filled completely up to the top mark, weighed, dried and then filled up to bottom mark and weighed. The difference in weight is the apparent weight of the water contained between the two marks. In this case the weight of the empty pipette is not needed. Flasks and Cylinders Calibrated “To Contain” (IN) Flasks and cylinders calibrated to contain are cleaned, dried and weighed empty, filled accurately and weighed again. The difference between the two weights, of course, is the apparent weight of the volume contained. Flasks and Cylinders Calibrated “To Deliver” (EX) If flasks and cylinders calibrated to deliver are to be calibrated, it will be FILLING AND EMPTYING The results obtained with volumetric apparatus depend not only on the accuracy with which the ware is calibrated, but also on the method of use. Insofar as possible, users should manipulate the instruments in exactly the same way as the manufacturer does when locating the calibration lines. The instructions given here apply particularly to apparatus used with a liquid which wets the glass and must be followed in every respect to obtain the most accurate results when such apparatus is to be calibrated. Since mercury does not wet glass, the factors of importance are cleanliness, the use of an ascending meniscus when possible, and the tapping of the vessel before reading the meniscus. The following rules have been suggested by the National Bureau of Standards. (These requirements may seem at times to be unduly detailed, but they are based on exact knowledge of the behavior of the various types of apparatus as determined experimentally.) Burettes Burettes should be held in a vertical position and filled to about 10 mm above the 0 line. Any liquid on the outside of the tip is removed at this time with clean filter paper. The setting to the 0 line is made by slowly emptying the excess liquid into a beaker or other receptacle with the side touching the edge of the tip. Any liquid remaining at the tip after setting has been made is touched-off against the wet side of the receptacle. When delivery is started, stopcocks should be completely open, even though it is necessary to slow the delivery near the end of a titration. If an exact quantity is desired, the liquid is slowed down when it is about 10 mm above the final line in order to set the meniscus accurately at this line. As soon as delivery has been completed the tip is touched to the side of the receiver and the latter removed from contact. Measurements made in laboratories with burettes ordinarily are from the 0 mark. Other initial points may be used on precision apparatus without serious error, but this is not advised with burets having very rapid delivery. Technical Data >> Glassware found best to weigh the filled piece first, empty it and weigh again. The second weight includes the film remaining on the walls after delivery. In all cases, the top of the flask or cylinder should be closed by a cap of some type to minimise evaporation losses. Care must also be taken in handling not to deposit moisture or grease from the hands on the surface of the glass. Therefore, the actual contact with the glass should be by means of a clean cloth, gloves or secure holding device. The entire neck of a flask is wetted by the distilled water and a drainage time of about 2 minutes allowed before completing the setting. To fill a cylinder, the water is allowed to run down one side only, although the entire wall is wetted for about 10 mm above the line to be calibrated by rotation or slightly tipping in several directions. A drainage time of about 2 minutes is allowed before the final adjustment is made. For the final adjustment, a pipette or dropper with a finely drawn point should be used. The temperature of the water can be taken in the filled piece just after the weighing has been completed unless the volume is small. In the latter case, if the thermometer happens to be at a different temperature, the reading obtained may be in error due to the effect of the comparatively large bulk of the thermometer in heating or cooling the water. The alternative is to fill the flask from a reservoir and use the temperature of the water in the reservoir. To calibrate centrifuge tubes, Babcock test bottles and similar articles by weighing the water contained, use the methods outlined for flasks and cylinders, except that the wall is wetted above the line being checked only far enough to insure a correctly shaped meniscus. Cylinders In filling a cylinder the liquid is allowed to flow down one side only. However, the entire wall is wetted for about 10 mm above the meniscus, by a gentle rotation of the cylinder or, preferably, by tipping it slightly in several directions. Here, a drainage time of about 2 minutes is allowed before completing the setting. The delivery of the contents of a cylinder is accomplished in the same way as described for a flask. (NOTE: These directions apply when highly accurate deliveries are wanted. In ordinary laboratory work where measurements are of approximate volumes only, no special precautions in filling and emptying cylinders are necessary.) You should bear in mind, however, that the accuracy you achieve is dependent on your method. Good method, consistently applied, will yield good results. Poor or sloppy methods will yield poor results. Flasks When a solution is made up to a definite strength in a volumetric flask, the entire neck usually is wet at the time the volume is adjusted, due to the mixing process. Consequently, in filling flasks the entire neck is wetted by the distilled water. A drainage time of about 2 minutes is allowed before completing the setting. If a flask is calibrated to deliver its indicated capacity, the delivery is made by gradually inclining the flask, avoiding, as much as possible, agitation of the contents and sloshing around of the liquid. The process should take half a minute. At the end of the emptying the instrument should be nearly vertical and should be held so for another half minute. Then the drop adhering to the lip should be touched off against the wet surface of the receiving vessel. Pipettes Pipettes also are held in a vertical position and filled to about 10 mm 93 Technical Data Technical Data above the 0 line. The technique of setting to this line is the same as used for burettes. The rate of outflow at this point is controlled by slight pressure of the forefinger on the top. With MEASURING and SEROLOGICAL PIPETTES, delivery is unrestricted, unless the liquid descends so rapidly that it would be impossible to stop at the desired place. In this case, however, delivery should be as fast as possible while retaining control with a finger. The tip is touched to the side of the receiver when delivery is completed and then removed immediately, except for certain types of serological pipette. These are “calibrated for blowout”, i.e., to deliver the indicated capacity when the small amount remaining in the tip after free delivery has ceased is blown out (with tip in contact with the wet side of the receiver, if possible) and added to the initial volume. As mentioned before, all blowout pipettes are marked with either a wide opaque ring, two narrower opaque rings near the top, or two printed rings near the top. (NOTE: With measuring pipettes of small capacity, there may be a tendency for free delivery to cease before the liquid reaches the lowest graduation lines. If this is so, the tip should be kept in contact with the receiving vessel during the delivery, and not just to touch off the last drop when delivery is finished.) VOLUMETRIC PIPETTES are held in a vertical position and outflow is unrestricted. The tip is touched to the wet surface of the receiving vessel and kept in contact with it until the water has ceased to flow. A count of two is made and the tip then withdrawn horizontally from contact with the receiver. The water remaining in the tip is not blown out, except in the case of Ostwald pipette used in biochemical work. These pipettes are usually “calibrated for blowout” and are marked also with an opaque ring near the top. Laboratory Glassware Catalogue 2012/13 Physical Properties of Glass 94 Glass is an inorganic product of fusion that has cooled to a rigid condition without crystallising and, therefore, has no melting point as such. There are, however, four temperatures that are of interest to the glassblower. They are: 1. The Working Point — the temperature at which glass has a viscosity of 104 poises. At this temperature, glass is soft enough for most lampworking or sealing operations. 2. The Softening Point — the temperature at which glass has a viscosity of 107.6 poises. In this temperature range glass will deform noticeably under its own weight: ASTM C 338. 3. The Annealing Point — the temperature at which the internal stress caused by rapid cooling from lampworking or forming temperatures may be substantially removed in a matter of minutes. It is determined by measuring the elongation rate versus temperature of a fiber of glass under conditions prescribed by ASTM Designation C 336. The values given herein are typical for production glasses. 4. The Strain Point — the temperature at which the internal strain in a glass is substantially relieved only after a matter of hours and not at a commercially desirable rate. It is determined by extrapolation of annealing point data for fiber elongation: ASTM C 336. Physical Properties of KG-33 and N-51A Glasses KG-33 N-51A Working Point 1255°C 1140°C Strain Point 513°C 530°C Annealing Point 565°C 570°C Softening Point 827°C 785°C Linear Coefficient of Expansion (from 0 to 300°C), in./in./°C 32x10-755x10-7 Density grams per cm3 2.22 2.33 Refractive Index—Sodium D line (.5893 microns) 1.47 1.49 Visible Light Transmission, 2 mm thickness 92% 91% Specific Heat (in g. cals per g. deg.) 0.204 (25 to 175°C) Thermal Conductivity (in cals/cm/cm2/sec/°C) 0.0027 Technical Data >> Glassware Table 2 0.204 (25 to 175°C) 0.0026 95 Technical Data Technical Data Ground Ware Standard Taper Symbol Spherical Joint Symbol is the symbol used to designate “standard taper” interchangeable joints, stoppers and stopcocks, complying with the requirements of ASTM E675 for stopcocks, stoppers and reagent bottle necks and E676 for interchangeable joints. All mating parts are finished to a 1:10 taper. is the designation for “spherical (semi-ball) joints” complying with ASTM E677. Laboratory Glassware Catalogue 2012/13 The size of a particular piece appears after the appropriate symbol. Due primarily to the greater variety of apparatus equipped with fittings, a number of different types of identifications are used, as follows: 96 Apparatus and Bottles • For joints - a two part number, as 24/40, with 24 being the approximate diameter in mm at the large end of the taper, and 40 the axial length of taper, also in mm. • For bottles - a single number, as 19, with 19 being the approximate diameter in mm of the opening at top of neck. • For glass stopcocks - a single number, as 2, with 2 being the approximate diameter in mm of the bore or bores through the plug. Flasks • For volumetric and Erlenmeyer flasks, graduated cylinders, etc. a single number as 19, with 19 again being the approximate diameter in mm at top of neck; however, there are differences in dimensions between the bottle and flask stoppers, see the individuals listings in this catalogue. The complete designation of a spherical joint also consists of a two part number, as 12/2, with 12 being the approximate diameter in mm of the ball and 2 the bore in mm of the ball and the socket. Product Standard Symbol is the symbol used to designate “product standard” compliance. Kimble glass stopcocks with plugs made of PTFE meet the requirements of ASTM Specification E911. The symbol is used to designate that Kimble stopcocks comply with this standard. All mating parts are finished to a 1:5 taper. Finally, for the PTFE plug ware, a single number is used, as with stopcocks. Thus, 2 means a stopcock with a bore of approximately 2 mm in the plug. * denotes products not stocked Technical Data >> Ground Ware 97 Technical Data Technical Data Ground Ware Laboratory Glassware Catalogue 2012/13 ( Computed Computed Diameter Diameter at at Standard Standard Approximate Approximate Approximate Approximate Large Large EndEnd of of Joint Joint SizeSizeDiameter Diameter at at Length Length of of Ground Ground Zone Zone Number Number Small Small EndEndGround Ground Zone Zone (Gauging (Gauging Point) Point) ( Designation)mmmm Designation) mmmm mmmm ( Computed Computed Diameter Diameter at at Standard Standard Approximate ApproximateApproximate ApproximateLarge Large EndEnd of of Joint Joint SizeSize Diameter Diameter at at Length Length of of Ground Ground Zone Zone Number Number Small Small EndEnd Ground Ground Zone Zone (Gauging (Gauging Point) Point) ( Designation) mmmm Designation) mmmm mmmm 7/25............. 7/25............. 5 5 10/30............ 10/30............ 7 7 12/30.......... 12/30..........9.5 9.5 14/35............ 14/35............ 11 11 19/38............ 19/38............ 15 15 25 30 30 35 38 25 30 30 35 38 7.5 7.5 10.010.0 12.512.5 14.514.5 18.818.8 5/125/12 ................ ................ 3.8 3.8 7/157/15 ................ ................ 6.0 6.0 10/18 10/18 ................ ................ 8.2 8.2 12/18 12/18 ...............10.7 ...............10.7 14/20 14/20 ...............12.5 ...............12.5 12 15 18 18 20 12 15 18 18 20 5.0 5.0 7.5 7.5 10.010.0 12.512.5 14.514.5 24/40............ 24/40............ 20 20 29/42............ 29/42............ 25 25 34/45............ 34/45............ 30 30 40/50............ 40/50............ 35 35 45/50............ 45/50............ 40 40 40 42 45 50 50 40 42 45 50 50 24.024.0 29.229.2 34.534.5 40.040.0 45.045.0 19/22 19/22 ...............16.6 ...............16.6 24/25 24/25 ...............21.5 ...............21.5 29/26 29/26 ...............26.6 ...............26.6 34/28 34/28 ...............31.7 ...............31.7 40/35 40/35 ...............36.5 ...............36.5 22 25 26 28 35 22 25 26 28 35 18.818.8 24.024.0 29.229.2 34.534.5 40.040.0 50/50............ 50/50............ 45 45 55/50............ 55/50............ 50 50 60/50............ 60/50............ 55 55 71/60............ 71/60............ 65 65 103/60 103/60 ........... ........... 97 97 50 50 50 60 60 50 50 50 60 60 50.050.0 55.055.0 60.060.0 71.071.0 103.0 103.0 Standard Dimensions Short-length Interchangeable Standard Dimensions for for Short-length Interchangeable Taper-Ground Joints Taper-Ground Joints ( 98 Standard Standard Dimensions Dimensions for for Medium-length Medium-length Interchangeable Taper-Ground Joints Interchangeable Taper-Ground Joints Standard Standard Dimensions Dimensions for for Full-length Full-length Interchangeable Interchangeable Taper-Ground Joints Taper-Ground Joints Computed Computed Diameter Diameter at at Standard Standard Approximate Approximate Approximate Approximate Large Large EndEnd of of Joint Joint SizeSizeDiameter Diameter at at Length Length of of Ground Ground Zone Zone Number Number Small Small EndEndGround Ground Zone Zone (Gauging (Gauging Point) Point) ( Designation)mmmm Designation) mmmm mmmm Standard Dimensions for for Interchangeable Standard Dimensions Interchangeable Spherical-Ground Joints Spherical-Ground Joints Standard Standard Joint Joint SizeSize Nominal Nominal Number Number Diameter Diameter ( Designation) ( Designation) mmmm Nominal Nominal Tube Tube Gauging Gauging BallBall Diameter Diameter Diameter Diameter I.D. I.D. mmmm inches inches 5/8............. 5/8............. 4.2 4.2 7/10............ 7/10............ 6.5 6.5 10/710/7 ............ ............ 9.3 9.3 10/10 10/10 ........... ........... 9.0 9.0 12/10 12/10 ...........11.5 ...........11.5 14/10 14/10 ...........13.5 ...........13.5 8 10 7 10 10 10 8 10 7 10 10 10 5.0 5.0 7.5 7.5 10.010.0 10.010.0 12.512.5 14.514.5 7/1 7/1 ................. ................. 7 7 12/112/1 ............... ............... 12 12 12/1.5 12/1.5 ............ ............ 12 12 12/212/2 ............... ............... 12 12 12/312/3 ............... ............... 12 12 12/512/5 ............... ............... 12 12 1 1 1 1 1.5 1.5 2 2 3 3 5 5 19/10 19/10 ...........17.8 ...........17.8 10 10 18.818.8 18/718/7 ............... ............... 18 18 7 7 .28125 .28125 ± .00005 ± .00005 .5000 .5000 ± .0001 ± .0001 .5000 .5000 ± .0001 ± .0001 .5000 .5000 ± .0001 ± .0001 .5000 .5000 ± .0001 ± .0001 .5000 .5000 ± .0001 ± .0001 * denotes products not stocked .7500 .7500 ± .0001 ± .0001 42 42 45 45 50 50 50 50 29.2 29.2 34.5 34.5 40.0 40.0 45.0 45.0 50/50............ 45 45 50/50............ 55/50............ 50 50 55/50............ 60/50............ 55 55 60/50............ 71/60............ 65 65 71/60............ 103/60 ........... 97 97 103/60 ........... 50 50 50 50 50 50 60 60 60 60 50.0 50.0 55.0 55.0 60.0 60.0 71.0 71.0 103.0 103.0 Standard Dimensions forfor Short-length Interchangeable Standard Dimensions Short-length Interchangeable Taper-Ground Joints Taper-Ground Joints ( Computed Computed Diameter at at Diameter Standard Approximate Large EndEnd of of StandardApproximate Approximate Approximate Large Joint SizeSizeDiameter at at Length of of Ground Zone Joint Diameter Length Ground Zone Number EndEndGround Zone (Gauging Point) Number Small Small Ground Zone (Gauging Point) Designation) mmmm mmmm ( Designation)mmmm 24/25 ...............21.5 24/25 ...............21.5 29/26 ...............26.6 29/26 ...............26.6 34/28 ...............31.7 34/28 ...............31.7 40/35 ...............36.5 40/35 ...............36.5 25 25 26 26 28 28 35 35 24.0 24.0 29.2 29.2 34.5 34.5 40.0 40.0 Standard Dimensions forfor Interchangeable Standard Dimensions Interchangeable Spherical-Ground Joints Spherical-Ground Joints Standard Standard Joint SizeSize Nominal Joint Nominal Number Diameter Number Diameter ( Designation) ( Designation) mmmm Nominal Nominal Tube Gauging BallBall Tube Gauging Diameter Diameter Diameter Diameter I.D. I.D. mmmm inches inches 5/8............. 4.24.2 5/8............. 7/10............ 6.56.5 7/10............ 10/7 ............ 9.39.3 10/7 ............ 10/10 ........... 9.09.0 10/10 ........... 12/10 ...........11.5 12/10 ...........11.5 14/10 ...........13.5 14/10 ...........13.5 8 8 10 10 7 7 10 10 10 10 10 10 5.05.0 7.57.5 10.0 10.0 10.0 10.0 12.5 12.5 14.5 14.5 7/17/1 ................. 7 7 ................. 12/1 ............... 12 12 12/1 ............... 12/1.5 ............ 12 12 12/1.5 ............ 12/2 ............... 12 12 12/2 ............... 12/3 ............... 12 12 12/3 ............... 12/5 ............... 12 12 12/5 ............... 1 1 1 1 1.51.5 2 2 3 3 5 5 19/10 ...........17.8 19/10 ...........17.8 24/12 ...........22.8 24/12 ...........22.8 29/12 ...........28.0 29/12 ...........28.0 34/12 ...........33.3 34/12 ...........33.3 40/12 ...........38.8 40/12 ...........38.8 10 10 12 12 12 12 12 12 12 12 18.8 18.8 24.0 24.0 29.2 29.2 34.5 34.5 40.0 40.0 18/7 ............... 18 18 18/7 ............... 18/9 ............... 18 18 18/9 ............... 28/12 ............. 28 28 28/12 ............. 28/15 ............. 28 28 28/15 ............. 35/20 ............. 35 35 35/20 ............. 7 7 .7500 ± .0001 .7500 ± .0001 9 9 .7500 ± .0001 .7500 ± .0001 12 12 1.1250 ± .00015 1.1250 ± .00015 15 15 1.1250 ± .00015 1.1250 ± .00015 20 20 1.3750 ± .00015 1.3750 ± .00015 45/12 ...........43.8 45/12 ...........43.8 50/12 ...........48.8 50/12 ...........48.8 55/12 ...........53.8 55/12 ...........53.8 60/12 ...........58.8 60/12 ...........58.8 71/15 ...........69.5 71/15 ...........69.5 12 12 12 12 12 12 12 12 15 15 45.0 45.0 50.0 50.0 55.0 55.0 60.0 60.0 71.0 71.0 35/25 ............. 35 35 35/25 ............. 40/25 ............. 40 40 40/25 ............. 50/30 ............. 50 50 50/30 ............. 65/40 ............. 65 65 65/40 ............. 75/50 ............. 75 75 75/50 ............. 102/75 ...........102 102/75 ...........102 25 25 25 25 30 30 40 40 50 50 75 75 .28125 ± .00005 .28125 ± .00005 .5000 ± .0001 .5000 ± .0001 .5000 ± .0001 .5000 ± .0001 .5000 ± .0001 .5000 ± .0001 .5000 ± .0001 .5000 ± .0001 .5000 ± .0001 .5000 ± .0001 Technical Data >> Ground Ware 29/42............ 25 25 29/42............ 34/45............ 30 30 34/45............ 40/50............ 35 35 40/50............ 45/50............ 40 40 45/50............ 1.3750 ± .00015 1.3750 ± .00015 1.6500 ± .00015 1.6500 ± .00015 2.0000 ± .00015 2.0000 ± .00015 2.5000 ± .0002 2.5000 ± .0002 3.0000 ± .00025 3.0000 ± .00025 4.0000 ± .0003 4.0000 ± .0003 99 Thermo Fisher Scientific is committed to working with you to increase efficiency, giving you the freedom to focus on your research. Our goal is to help you succeed. However you measure success, we can provide the resources and the programs to help you achieve it. By choosing Thermo Fisher, you have selected a partner with over a century of experience. Australia: For customer service, call 1300-735-292 Visit us online at: www.thermofisher.com.au New Zealand: For customer service, call 0800-933-966 Visit us online at: www.thermofisher.co.nz 1338168170-01-0512-GRP ©2012 Thermo Fisher Scientific rights reserved. © 2012 Thermo Fisher Scientific Inc. AllInc. rightsAllreserved. Specifications, terms & pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.