Ceramic Log 14 24 15 25
Transcription
Ceramic Log 14 24 15 25
Technical Specification Bulletin Number TB184 Fuel Type Gas Date of Issue Ed i t i o n Jan 2006 1 Ceramic Log Effect Fitting H & S 14,15 & 24,25 Page Number 1 Installation of the Gas Log Effect If any of the components of the log effect or burner are broken DO NOT INSTALL . Contact your stove supplier for replacements. The log effect kit is not covered by the stove`s warranty for accidental damage, so great care should be taken when handling the ceramic burner and logs. It is important that the logs and ember fibres are installed in accordance with these instructions as any deviation may cause poor combustion. The addition of further ceramic logs or coals is strictly prohibited. Back Log Identified by one round hole and one slot, which locate the log on the ceramic burner base. Left Hand Log Identified by the knot on one side. Right Hand Log Identified by the “V” at one end. Slot must locate onto tongue Front Log Identified by the one round hole which locates the log on the ceramic burner base. Euroheat Distributors (HBS) Ltd., Unit 2, Court Farm Business Park, Bishops Frome, Worcestershire, WR6 5AY United Kingdom Telephone Technical Support 01885 491117 Facsimile 01885 491101 Reception 01885 491100 Email [email protected] Wed Site sales www.euroheat co.uk Latest Technical Information www.euroheat.co.uk/support Technical Specification Bulletin Number TB184 Fuel Type Gas Date of Issue Ed i t i o n Jan 2006 1 Ceramic Log Effect Fitting H & S 14,15 & 24,25 Page Number 2 Placement of the Ember Glow Fibres Platinum ember glow fibres are made from high grade ceramic wool. The wool is similar to fibreglass and should be handled carefully. We recommend the use of suitable dust mask, gloves or tweezers when placing the embers in position. Wash hands immediately after touching to avoid irritation. Do not store the embers close to flammable liquids. The embers must be placed correctly in order to function properly. Tease out the fabric to form loose, irregular shapes. Do not compress the embers or force into position. Important: Tease out fabric to form loose, irregular shapes. Use of embers With the embers correctly placed they glow and flicker similar to glowing ash. Their placement is important as the effect produced can only occur when they are heated by the gas jets or by direct radiant heat. Once placed small movements of the embers location can improve the effect. By rubbing embers into the faces of the logs which are heated by the gas jets, the fibres which adhere to the logs will glow. With suitable gloves take a square of ember glow and gently rub the material into the area`s of logs which glow when in operation (see the log fitting instructions which follow). The pack containing the ember glow fibres contains more than required. The additional embers should be kept for further service requirements. Euroheat Distributors (HBS) Ltd., Unit 2, Court Farm Business Park, Bishops Frome, Worcestershire, WR6 5AY United Kingdom Telephone Technical Support 01885 491117 Facsimile 01885 491101 Reception 01885 491100 Email [email protected] Wed Site sales www.euroheat co.uk Latest Technical Information www.euroheat.co.uk/support Technical Specification Bulletin Number TB184 Fuel Type Gas Date of Issue Ed i t i o n Jan 2006 1 Ceramic Log Effect Fitting H & S 14,15 & 24,25 Page Number 3 Ember Glow Fibres Placement To left side of burner jets In front of burner jets To right side of burner jets Over burner jets 1. Fit the largest log with the hole and slot in the base corresponding to the peg and tongue at the back of the ceramic burner, ensuring that the peg goes into the hole on the log and the tongue goes into the slot. Place 2-3 pieces of ember glow fibres (A) just to the left hand side of the burner jets. Place 3-4 pieces of ember glow fibres (B) just to the right hand side of the burner jets. Place 6-7 ember glow fibres (C) just in front of the burner jets. Note: if placed over the burner jets, flame height will be greatly reduced. (A) Position of 2-3 embers Rub ember glow into the surface of the burnt section (B) Position of 3-4 embers (D) Position 6-7 embers Euroheat Distributors (HBS) Ltd., Unit 2, Court Farm Business Park, Bishops Frome, Worcestershire, WR6 5AY United Kingdom Telephone Technical Support 01885 491117 Facsimile 01885 491101 Reception 01885 491100 Email [email protected] Wed Site sales www.euroheat co.uk Latest Technical Information www.euroheat.co.uk/support Technical Specification Bulletin Number TB184 Fuel Type Gas Date of Issue Ed i t i o n Jan 2006 1 Ceramic Log Effect Fitting H & S 14,15 & 24,25 Page Number 4 2. Fit the second largest log with the one hole in the base locating it on the peg in the middle of the ceramic burner. Place 6-7 ember glow fibres (D) just in front of the burner jets. Rub ember glow into the surface of the burnt section (D) Position 6-7 embers 3. Fit the right hand log (E) with the “V” corresponding to the two indentations, in the burner base at the right hand end of the front log. The other end of the log resting upon the back log. Fit the left hand log (F) with the knot corresponding to the indentations, at the left hand end of the front log. The other end of the log resting upon the back log. (F) (E) Euroheat Distributors (HBS) Ltd., Unit 2, Court Farm Business Park, Bishops Frome, Worcestershire, WR6 5AY United Kingdom Telephone Technical Support 01885 491117 Facsimile 01885 491101 Reception 01885 491100 Email [email protected] Wed Site sales www.euroheat co.uk Latest Technical Information www.euroheat.co.uk/support