MIL-PRF-39012E Standards - San-tron

Transcription

MIL-PRF-39012E Standards - San-tron
INCH-POUND
MIL-PRF-39012E
27 April 2005
SUPERSEDING
MIL-PRF-39012D
13 July 1995
PERFORMANCE SPECIFICATION
CONNECTORS, COAXIAL, RADIO FREQUENCY, GENERAL SPECIFICATION FOR
This specification is approved for use by all Departments
and Agencies of the Department of Defense.
1. SCOPE
1.1 Scope. This specification covers the general requirements and tests for radio frequency
connectors used with flexible RF cables and certain other types of coaxial transmission lines.
1.2 Classification. Connectors are of the following classes, categories, and Part or Identifying
Number (PIN), as specified (see 3.1).
1.2.1 Class. The class of connectors consists of the following:
a. Class 1 - A class 1 connector is a connector which is intended to provide superior RF
performance at specified frequencies, and for which all RF characteristics are completely
defined.
b. Class 2 - A class 2 connector is intended to provide mechanical connection within an RF circuit
providing specified RF performance.
Comments, suggestions, or questions on this document should be addressed to: Defense
Supply Center Columbus, ATTN: VAI, P. O. Box 3990, Columbus OH 43218-3990 or by email to
[email protected] . Since contact information can change, you may want to verify the
currency of this address information using the ASSIST Online database at
http://assist.daps.dla.mil.
AMSC N/A
FSC 5935
MIL-PRF-39012E
1.2.2 Categories. The categories of connectors are designated by an A (field serviceable), B (nonfield replaceable), C (field replaceable solder center contact), D (field replaceable crimp center
contact), E (field replaceable) and F (field replaceable crimp, for semirigid cable) as follows:
a. Category A - Connectors, which do not require special tools to assemble are designated as
category A connectors. Standard wrenches, soldering equipment, pliers, etc., are not defined as
special tools.
b. Category B - Connectors, which require special tools to be assembled are designated as
category B connectors. These connectors may be used for original installations only. Field
replacement is intended to be made by categories A, C, D, E, or F connectors, which will provide
the same form, fit and function. Category B connectors will not be stocked or procured by the
Government.
c. Category C - Connectors, which require only standard military crimping tools and standard cable
stripping dimensions to assemble, are designated as category C connectors. The standard
military crimping tool is as specified (see 3.1).
d. Category D - Connectors, which require only standard military crimp tools for the center contact
and outer ferrule, and standard cable stripping dimensions to assemble are designated as
category D connectors. The standard military crimp tool is as specified (see 3.1).
e. Category E - Connectors using semi-rigid cables with standard stripping dimensions and using
standard military tools. The method of assembly of the connector to the cable outer conductor
will be by solder.
f.
Category F - Connectors using semirigid cables with standard stripping dimensions and using
standard military assembly tools. The method of assembly of the connector to the cable will be
solderless.
1.2.3 PIN. The PIN consists of the letter “M” followed by the basic specification sheet number, and a
sequentially assigned four-digit dash number. The first digit in the dash number designates the material
and plating of the connector body (shell); i.e., “0” for silver plated brass, “3” for passivated corrosionresistant steel, “4” for gold plated copper beryllium, or "7" for nickel plated brass.
Example:
M39012/
01
-
XXXX
General specification
Dash number from
specification sheet (see 3.1)
Specification sheet
The “-“ designates a standard military PIN. This position, when filled with the letter ‘B’ (i.e.
M39012/01BXXXX), signifies a military PIN, which is for OEM use only. The part is assembled to the
cable with special tooling. Acquisition of this type part by any agency other than OEM’s is prohibited and
will result in the substitution of the equivalent military replacement part (i.e., if “M39012/01BXXXX” is
submitted for acquisition, “M39012/01-XXXX” will be recommended.)
2
MIL-PRF-39012E
2. APPLICABLE DOCUMENTS
2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification.
This section does not include documents cited in other sections of this specification or recommended for
additional information or as examples. While every effort has been made to ensure the completeness of
this list, document users are cautioned that they must meet all specified requirements cited in sections 3,
4, or 5 of this specification, whether or not they are listed.
2.2 Government documents.
2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks
form a part of this document to the extent specified herein. Unless otherwise specified, the issues of
these documents are those cited in the solicitation or contract.
FEDERAL STANDARDS
FED-STD-H28 -
Screw-Thread Standards for Federal Services
COMMERCIAL ITEM DESCRIPTIONS
A-A-59588
-
Rubber, Silicone
DEPARTMENT OF DEFENSE SPECIFICATIONS
(See ASSIST database for list of specification sheets)
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-130
MIL-STD-202
MIL-STD-348
MIL-STD-889
-
Identification Marking of U.S. Military Property
Test Methods for Electronic and Electrical Component Parts
Radio Frequency Connector Interfaces
Dissimilar Metals
(Copies of these documents are available online at http://assist.daps.dla.mil/quicksearch/ or
http://assist.daps.dla.mil. or from the Standardization Documents Order Desk, 700 Robbins Avenue,
Building 4D, Philadelphia, PA 19111-5094.)
2.3 Non-Government publications. The following documents form a part of this document to the extent
specified herein. Unless otherwise specified, the issues of these documents are those cited in the
solicitation or contract.
ASTM INTERNATIONAL
ASTM A342
ASTM A484
ASTM A582
ASTM B16
ASTM B36
ASTM B88
ASTM B121
ASTM B124
ASTM B139
-
Materials, Feebly Magnetic, Permeability of
Steel, Bars, Billets and Forgings, Stainless
Free-Machining Stainless and Heat-Resisting Steel Bars
Rod, Brass, Free-Cutting, Bar and Shapes for use in Screw Machines
Plate, Brass, Sheet, Strip, and Rolled Bar
Tube, Water, Seamless Copper
Plate, Leaded Brass, Sheet, Strip, and Rolled Bar
Copper and Copper Alloy Forging Rod, Bar, and Shapes
Rod, Phosphor Bronze, Bar, and Shapes
3
MIL-PRF-39012E
ASTM B152 ASTM B194 ASTM B196 ASTM B197 ASTM B488 ASTM B700 ASTM D2116 ASTM D4894 ASTM D4895 -
Copper Sheet, Strip, Plate, and Rolled Bar
Copper-Beryllium Alloy Plate, Sheet, Strip and Rolled Bar
Rod and Bar, Copper-Beryllium Alloy
Wire, Alloy, Copper-Beryllium
Gold for Engineering Uses, Electrodeposited Coatings of
Electrodeposited Coatings of Silver for Engineering Uses
Molding and Extrusion Materials, FEP-Fluorocarbon
Polytetrafluoroethylene (PTFE) Grandular Molding and RAM Extrusion Materials
Polytetrafluoroethylene (PTFE) Resins Produced From Dispersion
(Copies of these documents are available from http://www.astm.org or ASTM International, P.O. Box
C700, 100 Barr Harbor Drive, Conshohocken, PA 19428-2959.)
AMERICAN NATIONAL STANDARDS INSTITUTE, (ANSI)
ANSI B46.1
-
Surface Texture (Surface Roughness, Waviness, and Lay)
(Copies of these documents are available online from http://www.ansi.org or from the American National
Standards Institute, 25 West 43 Street, 4th Floor, New York, NY 10036.)
IEEE Operations Center
IEEE Standard 287
-
Precision Coaxial Connectors
(Copies of these documents are available online from http://[email protected] or
from the IEEE Operations Center, 445 Hoes Lane, Piscataway, New Jersey 08854-1331.)
AEROSPACE INDUSTRIES ASSOCIATION OF AMERICA INC. (AIA/NAS)
NASM20995
-
Wire, Safety or Lock
(Copies of these documents are available online from http://aia-aerospace.org or from the Aerospace
Industries Association of America, 1000 Wilson Boulevard, Suite 1700, Arlington, VA 22209-3901.)
SOCIETY OF AUTOMOTIVE ENGINEERS (SAE)
SAE-AMS-QQ-N-290
SAE-AMS-2700
-
Nickel Plating (Electrodepostied)
Passivation of Corrosion Resistant Steels
(Copies of these documents are available online from http://www.sae.org or from the Society of
Automotive Engineers, 400 Commonwealth Drive, Warrandale. PA 15096-001.)
ELECTRONIC INDUSTRIES ALLIANCE (EIA)
EIA-364 - Electrical Connector/Socket Test Procedures Including
(Copies of these documents are available online at http://www.eia.org or from the Electronic Industries
Alliance, Technology Strategy & Standards Department, 2500 Wilson Boulevard, Arlington, VA 22201.)
4
MIL-PRF-39012E
2.4 Order of precedence. In the event of a conflict between the text of this document and the
references cited herein (except for related specification sheets), the text of this document takes
precedence. Nothing in this document, however, supersedes applicable laws and regulations unless
a specific exemption has been obtained.
3. REQUIREMENTS
3.1 Specification sheets. The individual item requirements shall be as specified herein and in
accordance with the applicable specification sheets. In the event of any conflict between
requirements of this specification and the specification sheet, the latter shall govern.
3.2 Qualification. Connectors furnished under this specification shall be products that are authorized
by the qualifying activity for listing on the applicable qualified products list before contract award (see
4.3 and 6.3).
3.3 Critical Interface material. Material shall be as specified herein and in table I. If materials other
than those specified are used, the contractor shall certify to the qualifying activity that the substitute
material enables the connectors to meet the requirements of this specification. Acceptance or
approval of any constituent material shall not be construed as a guaranty of the acceptance of the
product. When a definite material is not specified, a material shall be used which will enable the
connector to meet the requirements of this specification.
TABLE I. Materials.
Component material
Steel
Brass
Phosphor bronze
Soft copper
Copper
Copper-Beryllium
PTFE fluorocarbon
FEP fluorocarbon
Silicon rubber
Applicable
specification
ASTM A484, ASTM A582,
ASTM B16, ASTM B36,
ASTM B121
ASTM B139
ASTM B152
ASTM B88, ASTM B124
ASTM B194, ASTM B196,
ASTM B197
ASTM D4894, ASTM D4895
ASTM D2116
A-A-59588
3.3.1 Critical interface materials and finish. Unless otherwise specified (see 3.1), connector center
contacts and bodies shall be plated in the following manner in order to meet the requirements of this
specification and avoid detrimental interactions between dissimilar metals.
3.3.1.1 Center contacts. The male pin shall be plated to a minimum gold thickness of 50 micro
inches (1.27µm) in accordance with ASTM B488, type II, code C, class 1.27, over 50 micro inches
(1.27µm) minimum of nickel in accordance with SAE-AMS-QQ-N-290, class 1, measured anywhere
along the mating surface, for all series. The socket contact shall be plated to a minimum of 50 micro
inches (1.27 µm) of gold in accordance with ASTM B488, type II, code C, class 1.27, over 50 micro
inches (1.27 µm) minimum of nickel in accordance with SAE-AMS-QQ-N-290, class 1, including the
I.D., measured at a depth of .040 inch minimum. The plating on non-significant surfaces in the I.D.
shall be of sufficient thickness to ensure plating continuity and uniform utility and protection. This
plating may consist of an underplate only. A silver underplate shall not be permitted.
5
MIL-PRF-39012E
NOTE: No PIN changes will be made as a result of this plating change. The change will be
tracked via the manufacturer’s date code.
3.3.1.2 Connector bodies. All brass bodied connectors shall be silver plated in accordance with
ASTM-B700 to a minimum thickness of 0.0002 inch (0.005 mm) over a copper underplate or shall be
nickel plated in accordance with SAE-AMS-QQ-N-290 over a copper underplate, only when specified
on the individual specification sheet. If not specifically noted the plating shall be silver. (Note of
caution! Nickel plated connectors may cause Passive Intermodulation (PIM) problems. The user is
ADVISED to check the application involved when choosing this type of plating.) All copper beryllium
bodied connectors shall be gold plated to a minimum thickness of 50 micro inches (1.27µm) in
accordance with ASTM B488, type II, code C, class 1.27, over a copper flash. All corrosion resistant
steel bodied connectors shall be passivated in accordance with SAE-AMS-2700, unless otherwise
specified (see 3.1). NOTE: Ferrous or nickel alloys shall not be used on brass or copper beryllium
bodied connectors (i.e. coupling nuts, etc.). (Past experience has shown that these plating conditions
allow these connectors to meet the performance requirements of this specification.)
3.3.2 Dissimilar metals. Dissimilar metals between which an electromotive couple may exist shall not
be placed in contact with each other. Reference is made to MIL-STD-889 for definition of dissimilar
metals.
3.3.3 Nonmagnetic materials. All parts (except hermetic sealed connectors) shall be made from
materials which are classed as nonmagnetic (see 3.8).
3.3.4 Spring members. Unless otherwise specified (see 3.1), center contact spring members shall
be made of copper beryllium.
3.3.5 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or
environmentally preferable materials should be used to the maximum extent possible, provided that
the material meets or exceeds the operational and maintenance requirements, and promotes
economically advantageous life cycle costs.
3.4 Configuration and features. Connectors shall be of the configuration and physical dimensions
specified (see 3.1). On class I connectors (see 1.2.1) each half of a connector pair must be
separately optimized in VSWR (see 4.6.11). It is not permitted to compensate for discontinuities of
one connector by the design of the mating connector.
3.4.1 Mating (visual indication). When applicable (see 3.1), a visual means shall be provided to
indicate when two mating connectors are properly mated.
3.4.2 Screw threads. Screw threads shall be in accordance with FED-STD-H28 unless otherwise
specified (see 3.1).
3.4.3 Connector interfaces. Connector interfaces shall be in accordance with MIL-STD-348 unless
otherwise specified (see 3.1).
3.5 Force to engage/disengage.
3.5.1 Bayonet and threaded types. When tested as specified in 4.6.2.1, the torque necessary to
completely couple or uncouple the connectors shall not exceed that specified (see 3.1). Also the
longitudinal force necessary to initiate the engaging or disengaging cycle shall not except that
specified (see 3.1).
6
MIL-PRF-39012E
3.5.2 “Push on” connector types. When tested as specified in 4.6.2.2, the forces necessary to fully
engage or disengage the connector shall not exceed that specified (see 3.1).
3.6 Coupling proof torque. When tested as specified in 4.6.3, the coupling mechanism (threaded
types) shall not be dislodged, and the connector shall meet requirements of 3.5.1. The interface
dimensions of the connector shall remain as specified (see 3.1).
3.7 Mating characteristics. When connectors are tested as specified in 4.6.4, the mating dimensions
shall be gauged as specified and the dimensions shall remain within the specified tolerances (see
3.1).
3.8 Permeability of nonmagnetic materials. When connectors (except hermetic sealed) are tested as
specified in 4.6.5, the permeability (Mu) shall be less than 2.0. The permeability does not apply to
connector hardware.
3.9 Hermetic seal (pressurized connectors). When connectors are tested as specified in 4.6.6, the
leakage rate shall not exceed that specified (see 3.1).
3.10 Leakage (pressurized connectors). When connectors are tested as specified in 4.6.7, there
shall be no leakage as detected by escaping air bubbles.
3.11 Insulation resistance. When connectors are tested as specified in 4.6.8, the insulation
resistance shall not be less than that specified (see 3.1).
3.12 Center contact retention. When all class I connectors, and class II where applicable (see 3.1)
are tested as specified in 4.6.9, the center contacts must not be displaced from the specified interface
dimensions in the uncabled connector by the application of the specified axial force (see 3.1) in either
direction or torque.
3.13 Corrosion. When connectors are tested as specified in 4.6.10, there shall be no exposure of the
base metal on the interface or mating surface, and they shall meet the requirements of 3.5.1 or 3.5.2
as applicable.
3.14 Voltage standing wave ratio (VSWR). When connectors are tested as specified in 4.6.11, the
VSWR shall not exceed that specified over the frequency range specified (see 3.1).
3.15 Connector durability. When connectors are tested as specified in 4.6.12, they shall show no
evidence of severe mechanical damage and the coupling device shall remain functional. Connectors
shall meet the applicable requirements of 3.5 and 3.7.
3.16 Contact resistance. When connectors are tested as specified in 4.6.13, the contact resistance
of the center contact, outer contact, and braid to connector shall be as specified (see 3.1). The
following statement takes precedence over any specification sheet interpretation. The outer contact
resistance values given for steel bodied connectors are typical values and are for engineering
information purposes only.
3.17 Dielectric withstanding voltage. When connectors are tested as specified in 4.6.14, there shall
be no evidence of breakdown.
7
MIL-PRF-39012E
3.18 Vibration. When the cabled (or wired, as applicable) connector is tested as specified in 4.6.15,
there shall be no electrical interruptions exceeding 1 microsecond (µs), or as otherwise specified (see
3.1). There shall be no evidence of visual mechanical damage after the test, and the contact
resistance of the center contact shall not be changed by more than the specified amount (see 3.1 and
3.16).
3.19 Shock (specified pulse). When the cabled (or wired, as applicable) connector is tested as
specified in 4.6.16, there shall be no electrical interruptions exceeding 1 µs unless otherwise specified
(see 3.1). There shall be no evidence of visual or mechanical damage after the test, and the contact
resistance of the center contact shall not be changed by more than the specified amount (see 3.1).
3.20 Thermal shock. After testing as specified in 4.6.17, there shall be no evidence of visual
mechanical damage to the connector and it shall meet the dielectric withstanding voltage requirement
(see 3.17), and the contact resistance specified for the center contact shall not be exceeded (see
3.16).
3.21 Moisture resistance. When connectors are tested as specified in 4.6.18, there shall be no
evidence of damage. They shall withstand the dielectric withstanding voltage specified (see 3.17),
and the insulation resistance shall not be less than that specified (see 3.11).
3.22 Corona level. When connectors are tested as specified in 4.6.19, at the altitude and voltage
specified (see 3.1), there shall be no evidence of sustained corona discharge.
3.23 RF high potential withstanding voltage. When connectors are tested as specified in 4.6.20,
there shall be no breakdown, or the leakage current specified shall not be exceeded (see 3.1).
3.24 Cable retention force. When connectors are tested as specified in 4.6.21, there shall be no
evidence of mechanical failure, loosening, rupture, or discontinuity. The direct clamping of the cable
jacket shall not be the primary method of cable retention.
3.25 Coupling mechanism retention force. When tested as specified in 4.6.22, the coupling
mechanism shall not be dislodged from the connector and shall be capable of meeting the
requirements of 3.5.1 immediately after the test.
3.26 RF leakage. When connectors are tested as specified in 4.6.23, the total leakage, cable to
cable shall not exceed that specified (see 3.1).
3.27 RF insertion loss. When connectors are tested as specified in 4.6.24, the insertion loss shall
not exceed that specified (see 3.1).
3.28 Assembly instructions. Complete assembly instructions shall be furnished by the vendor with
each connector procured under this specification. It is not the intention of this specification to require
assembly instructions with uncabled connectors (i.e., solder pot, solder tab or posts, etc.). Assembly
instructions shall include:
a.
b.
c.
d.
Cable preparation – stripping dimensions and tolerances.
List and description of crimping or special tools if required (see 1.2.2).
Pictorial presentation of sub-assemblies and loose piece parts
Sufficient pertinent dimensions for verification of correct parts; as a minimum the cable
entry openings for conductor, dielectric, braid, and jacket shall be specified.
e. Recommended cable clamp tightening torque (if applicable).
f. Military PIN and manufacturer’s PIN.
8
MIL-PRF-39012E
3.29 Marking. Connectors and associated fittings shall be permanently and legibly marked in
accordance with the general marking requirements of ML-STD-130 with the military PIN (see 1.2.3),
manufacturer’s federal supply code, and final assembly date code. The marking location is optional;
when practicable, a location should be picked that will be least likely to be covered in cable assembly
or installation. Marking is required on all parts manufactured to this specification unless specifically
excepted (see 3.1).
3.30 Workmanship. Connectors and associated fittings shall be processed in such a manner as to
be uniform in quality and shall be free from sharp edges, burrs and other defects that will affect life,
serviceability or appearance.
3.31 Manufacturers’ control drawing. Connector manufacturers shall insure that special tooling and
dies are documented. The replacement category A, C, D, E, or F PIN’s shall be listed on the
manufacturers’ control drawing.
3.32 Safety wire hole pullout. When applicable (see 3.1), the connectors are to be tested as
specified in 4.6.25. There shall be no evidence of hole tear out.
4. VERIFICATION
4.1 Classification of inspections. The inspection requirements specified herein are classified as
follows:
a. Qualification inspection (see 4.3)
b. Conformance inspection (see 4.4).
c. Periodic inspection (see 4.5).
4.2 Inspection conditions. Unless otherwise specified, all inspections shall be performed in
accordance with the test conditions specified in the “GENERAL REQUIREMENTS” of MIL-STD-202
or EIA-364. For each test of threaded coupling connectors, where the test is performed on mated
pairs, the pair shall be torqued to the specified value (see 3.1).
4.3 Qualification inspection. Qualification inspection shall be performed at a laboratory acceptable to
the Government (see 6.3) on sample units produced with equipment and procedures normally used in
production.
4.3.1 Sample size. Thirty class 1 connectors of the same PIN, or eighteen class 2 connectors of the
same PIN with its mating connector (see 1.2.1), shall be subjected to qualification inspection.
4.3.2 Group qualification. For group qualification of all series of connectors covered by this
specification (see 3.1). Group qualification will be limited to those connectors for which evidence of
manufacturing capability is demonstrated by providing engineering drawings to the qualifying agency.
The Government reserves the right to authorize performance of any or all qualification inspection of
additional types in the group that are considered necessary for qualification within each group.
4.3.3 Inspection routine. The sample shall be subjected to the inspections specified in table II. All
sample units shall be subjected to the inspection of group I. The sample units shall then be divided
equally into six groups of 5 units (class 1) or three units each (class 2) and subjected to the inspection
for their particular group and in the sequence given for that group.
9
MIL-PRF-39012E
4.3.4 Failures. One or more failures shall be cause for refusal to grant qualification approval.
4.3.5 Retention of qualification. To retain qualification, the contractor shall verify in coordination with
the qualifying activity the capability of manufacturing products which meet the performance
requirements of this specification. Refer to the qualifying activity for the guidelines necessary to
retain qualification to this particular specification. The contractor shall immediately notify the
qualifying activity at any time that the inspection data indicates failure of the qualified product to meet
the performance requirements of this specification.
10
MIL-PRF-39012E
TABLE II. Qualification inspection.
Examination or test
Group I
Requirement paragraph
Test method paragraph
3.3
3.3.1
3.3.2
3.4
3.29
3.4.1
4.6.1.1
3.5.1
3.5.2
3.6
3.7
3.8
3.30
3.9
3.10
3.11
4.6.2.1
4.6.2.2
4.6.3
4.6.4
4.6.5
4.6.1
4.6.6
4.6.7
4.6.8
Center contact retention
Corrosion
Group III
3.12
3.13
4.6.9
4.6.10
VSWR (cabled)
Connector durability
Safety wire hole pullout
3.14
3.15
3.32
4.6.11
4.6.12
4.6.25
3.16
3.17
3.18
3.19
3.20
3.21
3.22
3.23
3.24
3.25
4.6.13
4.6.14
4.6.15
4.6.16
4.6.17
4.6.18
4.6.19
4.6.20
4.6.21
4.6.22
3.26
4.6.23
3.27
4.6.24
3.16
4.6.13
Visual and mechanical examination
Material
Finish
Dissimilar metals
Configuration and features (dimensions)
Marking
Mating (visual indication)
Force to engage/disengage
Bayonet and threaded types
“Push-on” connector types
Coupling proof torque
Mating characteristics
Permeability of nonmagnetic materials
Workmanship
Hermetic seal (pressurized connectors only)
Leakage (pressurized connectors only)
Insulation resistance
4.6.1.2
4.6.1.1
Group II
Group IV
Center contact resistance
Dielectric withstanding voltage
Vibration 1/
Shock (specified pulse) 1/
Thermal shock
Moisture resistance
Corona level 1/
RF high potential withstanding voltage 1/
Cable retention force
Coupling mechanism retention force
Group V
RF leakage 1/
Group VI
RF insertion loss 1/
Group VII
Contact resistance
See note at end of table.
11
MIL-PRF-39012E
TABLE II. Qualification inspection – Continued.
1/ These tests to be performed only during initial qualification as long as the qualifying design and
manufacturing process has not been changed.
4.4 Conformance inspection.
4.4.1 Inspection of product for delivery. Inspection of product for delivery shall consist of groups A
and B inspection.
4.4.1.1 Inspection lot. An inspection lot shall consist of all connectors of the same PIN produced
under essentially the same conditions, and offered for inspection at one time.
4.4.1.2 Group A inspection. Group A inspection shall consist of the inspection specified in table III in
the order shown.
4.4.1.2.1 Sampling plan (group A). Table III tests shall be performed on a production lot basis.
Samples shall be selected in accordance with table IV. If one or more defects are found, the lot shall
be screened for that particular defect and defective parts removed. A new sample of parts shall be
selected in accordance with table IV and all group A tests again performed. If one or more defects
are found in the second sample, the lot shall be rejected and shall not be supplied to this
specification. When defects have no effect on the use or performance of the subject parts, reworking
of the parts may be permitted upon approval of both the Preparing and Qualifying activities. Such
allowances are infrequent and only apply to particular circumstances..
TABLE III. Group A inspection.
Inspection
Visual and mechanical examination
Material
Finish 1/
Dissimilar metals
Configuration and features
Marking
Workmanship
Mating (visual indication)
Dielectric withstanding voltage
Hermetic seal (pressurized
connectors only)
Leakage (pressurized connectors
only)
Requirement
paragraph
3.3
3.3.1
3.3.2
3.4
3.29
3.30
3.4.1
3.17
Test method
paragraph
Sampling
procedure
4.6.1.1
See table IV
4.6.14
3.9
4.6.6
3.10
4.6.7
1/ Verification of finish may be accomplished using the manufacturer’s process controls providing these
controls are clearly equal to or more stringent than the requirements of this specification.
4.4.1.2.2 Visual inspection (group A inspection). Each connector shall be visually examined for
completeness, workmanship, and identification requirements. Attention shall be given to those
assemblies that require a gasket to determine the condition of the gasket. Gaskets missing, twisted,
buckled, kinked, or damaged in any way shall be cause for rejection.
12
MIL-PRF-39012E
TABLE IV. Inspection level.
Lot size
Visual and mechanical inspection
1 to
19
20 to
280
281 to
1,200
1,201 to
3,200
3,201 to 10,000
10,001 to 35,000
35,001 to 150,000
150,001 to 500,000
500,001 and
over
All
20
47
53
68
77
96
119
143
4.4.1.3 Group B inspection. Group B inspection shall consist of the inspections specified in table V in
the order shown, and shall be made on sample units which have been subjected to and passed the
group A inspection. Connectors having identical piece parts may be combined for lot purposes and
shall be in proportion to the quantity of each PIN numbered connector produced.
4.4.1.3.1 Group B sampling plan. A sample of parts shall be randomly selected in accordance with
table VI. If one or more defects are found, the lot shall be screened for that particular defect and
defects removed. After screening and removal of defects, a new sample of parts shall be randomly
selected and subjected to all tests in accordance with table V. If one or more defects are found in the
second sample, the lot shall be rejected and shall not be supplied to this specification.
TABLE V. Group B inspection.
Inspection
Force to engage/disengage
Bayonet and threaded type
“Push-on” connector type
Coupling proof torque
Mating characteristics
Permeability of nonmagnetic materials
Insulation resistance
VSWR (cabled) 1/
Requirement paragraph
Test method paragraph
3.5.1
3.5.2
3.6
3.7
3.8
3.11
3.14
4.6.2.1
4.6.2.2
4.6.3
4.6.4
4.6.5
4.6.8
4.6.11
1/ Destructive test. When a VSWR failure occurs the defect which caused the failure shall be determined
and the entire lot shall be screened for that/those particular defects and defects removed. A new
sample of parts shall be selected in accordance with table VI and all tests again performed.
13
MIL-PRF-39012E
TABLE VI. Inspection level.
Lot size
Sample size
VSWR sample size
1 to
4
5 to
15
16 to
50
51 to
90
91 to
150
151 to
280
281 to
500
501 to
1,200
1,201 to
3,200
3,201 to 10,000
10,001 to 35,000
35,001 and over
All
5
5
5
11
13
16
19
23
29
35
40
1
1
2
3
3
3
3
5
5
5
5
8
4.4.1.3.2 Disposition of sample units. Sample units which have passed all the group B inspection
may be delivered on the contract or purchase order, if the lot is accepted. Any connector deformed or
otherwise damaged during testing shall not be delivered on the contract or order.
4.5 Periodic inspection. Periodic inspection shall consist of group C. Except where the results of
these inspections show noncompliance with the applicable requirements (see 4.5.1.4), delivery of
products which have passed groups A and B shall not be delayed pending the results of these
periodic inspections.
4.5.1 Group C inspection. Group C inspection shall consist of the inspections specified in table VII,
in the order shown. Group C inspection shall be made on sample units selected from inspection lots
which have passed the groups A and B inspection.
4.5.1.1 Sampling plan. Twelve sample units of the same PIN shall be selected from the first lot
produced after the date of notification of qualification. Thereafter, twelve sample units of the same
PIN shall be selected from current production after 200,000 connectors have been produced, or not
less than once every 3 years, whichever occurs first. The sample units shall be divided equally and
subjected to the inspections of the six subgroups.
4.5.1.2 Failures. If one or more sample units fails to pass group C inspection, the lot shall be
considered to have failed.
4.5.1.3 Disposition of sample units. Sample units which have been subjected to group C inspection
shall not be delivered on the contract or order.
14
MIL-PRF-39012E
4.5.1.4 Noncompliance. If a sample fails to pass group C inspection, the manufacturer shall notify
the qualifying activity and the cognizant inspection activity of such failure and take corrective action
on the materials or processes, or both, as warranted, and on all units of product which can be
corrected and which are manufactured under essentially the same materials and processes, and
which are considered subjected to the same failure. Acceptance and shipment of the product shall be
discontinued until corrective action, acceptable to the qualifying activity has been taken. After the
corrective action has been taken, group C inspection shall be repeated on additional sample units (all
tests and examinations, or the test which the original sample failed, at the option of the qualifying
activity). Groups A and B inspections may be reinstituted, however, final acceptance and shipment
shall be withheld until the group C inspection has shown that the corrective action was successful. In
the event of failure after reinspection, information concerning the failure shall be furnished to the
cognizant inspection activity and the qualifying activity.
TABLE VII. Group C inspection.
Inspection
Subgroup 1
Requirement paragraph
Test method paragraph
Center contact retention
Corrosion
Subgroup 2
3.12
3.13
4.6.9
4.6.10
VSWR (cabled)
Connector durability
Safety wire hole pullout
3.14
3.15
3.32
4.6.11
4.6.12
4.6.25
3.16
3.18
3.19
3.20
3.21
3.22
3.23
3.24
3.25
4.6.13
4.6.15
4.6.16
4.6.17
4.6.18
4.6.19
4.6.20
4.6.21
4.6.22
3.26
4.6.23
3.27
4.6.24
3.16
4.6.13
Subgroup 3
Center contact resistance
Vibration 1/
Shock (specified pulse) 1/
Thermal shock
Moisture resistance
Corona level 1/
RF high potential withstanding voltage 1/
Cable retention forces
Coupling mechanism retention force
Subgroup 4
RF leakage 1/
Subgroup 5
RF insertion loss 1/
Subgroup 6
Contact resistance
1/ These tests to be performed only during initial qualification as long as the qualifying design and
manufacturing process has not been changed.
15
MIL-PRF-39012E
4.6 Methods of inspection.
4.6.1 Test methods. The following identified tests and test methods assure connector integrity within
typical operating conditions and applications. Alternate commercial industry standard test methods
are allowed; however when an alternate method is used, the qualifying activity must be notified prior
to the performance of the test. The test method described herein are proven methods and shall be
the referee methods in case of dispute.
4.6.1.1 Visual and mechanical examination. Connectors and associated fittings shall be examined to
verify that the design, construction, physical dimensions, assembly instructions, marking and
workmanship are in accordance with the applicable requirements (see 3.1, 3.3, 3.4, 3.28, 3.29, and
3.30).
4.6.1.2 Dimensional examination. Mating dimensions shall be examined by mating the connector
with its applicable mating gauges or other suitable means acceptable to the Government.
NOTE: The associated individual specification sheets show the overall dimension of the
connector when assembled to the appropriate cable. Mating interface dimension are to be
found in MIL-STD-348. The cable end construction and other dimensions are controlled by
performance requirements of the specification (i.e., cable retention, VSWR, RF leakage, etc.,
with cable in place).
4.6.2 Force to engage/disengage.
4.6.2.1 Bayonet and threaded types (see 3.5.1). The connector shall be engaged with its mating
standard part (see 3.1). During the entire coupling/uncoupling cycle (until the connector is fully
engaged/disengaged) the forces and/or torques necessary shall not exceed those specified (see 3.1).
A threaded coupled connector is fully engaged with its mating standard part when their reference
planes (see MIL-STD-348) coincide. A bayonet coupled connector is fully engaged with its mating
standard part when the bayonet studs have passed the detent and their reference planes coincide.
No additional tightening torque shall be applied. The mating standard part is a steel jig containing the
critical interface dimensions finished to the tolerances specified (see MIL-STD-348). Its spring
members when applicable shall be heat treated beryllium copper. The surface finish or mating
surfaces shall be 16 microinches, maximum in accordance with ANSI B46.1.
4.6.2.2 “Push-on” connector types (see 3.5.2). The connector under test shall be engaged with its
standard mating part (gauge). During this engaging cycle the force necessary to fully engage the
connectors shall not exceed that specified (see 3.1). Upon completion of engagement, an opposite
force necessary for disengagement shall be applied. This force shall be within the limits specified,
and shall include any unlatching forces required.
4.6.3 Coupling proof torque (see 3.6). The connector under test shall be engaged with its mating
standard part (gauge) and the coupling nut tightened to the torque value specified (see 3.1). After
one minute the connector under test and its mating standard part shall be disengaged.
4.6.4 Mating characteristics (see 3.7). After insertion of the specified oversize pin the specified
number of times (see 3.1), the contact to be tested shall be held rigid by means of a suitable jig or
fixture. A gauge containing the test pin or test ring and a suitable force indicating dial shall be aligned
to within 0.004 TIR of any plane passing through the axis of the contact under test. Engagement or
withdrawal of the test pin or test ring shall be made smoothly and at such a rate that the dial does not
bounce or otherwise give a false reading. The test pin or test ring may be chamfered to facilitate
entry, but the specified engagement length shall not include the chamfer length and the finish shall be
as specified and in accordance with ANSI B46.1.
16
MIL-PRF-39012E
4.6.5 Permeability of nonmagnetic materials (see 3.8). The permeability of the connector shall be
measured with an indicator conforming to ASTM A342.
4.6.6 Hermetic seal (see 3.9). Connectors shall be tested in accordance with method 112,
MIL-STD-202. The following details shall apply:
a. Test condition letter: C
b. Procedure number: I.
c.
Leakage rate sensitivity: 10-8 cubic centimeters per second.
4.6.7 Leakage (pressurized) (see 3.10). Connectors shall be subjected to air pressure specified (see
3.1) applied to one end, and the whole assembly immersed in water at a temperature of 15º to 25ºC.
The connector shall remain immersed for at least 2 minutes.
4.6.8 Insulation resistance (see 3.11). Connectors without cables (when applicable) shall be tested
in accordance with method 302, test condition B, MIL-STD-202. Measure between the center contact
and body.
4.6.9 Center contact retention (see 3.12). An axial force (see 3.1) shall be applied, first in one
direction and then the other, to the center contact of an assembled and uncabled connector utilizing a
method and force measuring device suitable to the Government. The inner contact shall be
inspected after the force has been applied in one direction and again after the force has been applied
in the opposite direction to determine if the contact has been displaced from the specified interface
dimensions. Torque: The torque specified shall be applied to the center contact of an unmated
connector for a minimum period of 10 seconds, as applicable (see 3.1).
4.6.10 Corrosion (see 3.13). Unmated and uncabled connectors shall be tested in accordance with
method 101, MIL-STD-202. The following details and exceptions shall apply:
a. Test condition letter: See 3.1.
b. Salt solution: 5 percent.
After exposure, connectors shall be washed, shaken and lightly brushed as specified in method 101
of MIL-STD-202 and then permitted to dry for 24 hours at 40ºC. Connectors shall then be examined
for evidence of corrosion, pitting, and ease of coupling.
4.6.11 VSWR (see 3.14). The VSWR shall be measured in accordance with the following procedure
or a method acceptable to the Government. In the event of dispute the method outlined herein shall
be used. Diagrams for the swept frequency VSWR system to check out the measurement
procedures are shown on figure 1.
In the basic measurement setup on figure 1, detector 1 provides a feedback signal to the swept RF
source in order to normalize the output signal of detector 2. The frequency-amplitude
characteristics of detectors 1 and 2 should be matched within .5 dB.
17
MIL-PRF-39012E
To measure VSWR several sweeps are made with the slotted line probe incrementally positioned
over at least a half wave length at the lowest frequency of interest. In this manner an X-Y display is
generated whose upper and lower envelope limits represent maximum and minimum amplitudes of
the standing wave for each frequency in the test band. A base line may be generated by making a
sweep with no input to the measurement channel amplifier. The resultant X-Y display is calibrated
according to the characteristics of the measurement channel detector and amplifier, e.g., linear,
square law, logarithmic, etc .
The VSWR test system is checked out successively terminating the slotted line with the elements
shown in steps 1 and 2 and sweeping the frequency over the specified test band (see 3.1). In step 1
the system VSWR shall be less than 1.02 + .004 F (F measured in GHz). In step 2, the system
VSWR shall be as specified (see 3.1).
For qualification and group C inspection (see tables II and VII), the system is checked out with the
slotted line terminated as in step 3 using the specified cable (see 3.1). The impedance variation
(random and/or periodic) from the nominal characteristic impedance specified for the selected test
cable should be no more than 1.0 percent when tested by time domain reflectometry. In step 3, the
system VSWR shall be as specified (see 3.1). For qualification and group C inspection, the
connector under test is measured with the slotted line terminated as in step 4. The VSWR shall be
as specified (see 3.1).
Group B inspection tests (see table V) are performed with the slotted line terminated as shown in
step 7. The input part of the cable simulator must have the same interface configuration,
dimensions, and dielectric as the recommended cable interface for the connector under test. The
cable simulator for group B inspection tests must meet the specified VSWR (see 3.1) when tested as
shown in step 6.
The standard precision adapter interface shall conform to IEEE Standard 287. Item 6 (standard
precision adapters) shall not exceed the specified VSWR requirements (see 3.1). Standard test
adapter designs shall be approved by the military qualifying agency.
4.6.12 Connector durability (see 3.15). Each connector under test shall be mated with a typical
production connector in accordance with this specification. The connector shall be subjected to the
number of cycles of mating and unmating specified (see 3.1). The connector and its mating part shall
be completely engaged and completely disengaged during this cycle. Lubrication of the threads or
rotational parts shall not be employed for this test unless specified (see 3.1). It is permissible to
shake or blow debris from the threads or interface surfaces at intervals of not less than 50 cycles.
Solvents or tools shall not be used for cleaning.
18
MIL-PRF-39012E
FIGURE 1. Swept frequency VSWR test.
19
MIL-PRF-39012E
FIGURE 1. Swept frequency VSWR test – Continued.
20
MIL-PRF-39012E
4.6.13 Contact resistance (see 3.16). All contact resistance tests shall be conducted with the
apparatus shown on figure 2. Circuit adjustments and the measurement procedures for all contact
resistance tests shall be in accordance with 4.6.13.1. The contact resistances to be measured are:
a. The contact resistance between the cable braid or outer conductor and the connector at the
point of contact.
b. The contact resistance of the mated outer conductor contacts (the coupling nut must be
removed for this measurement).
c.
The contact resistance of the mated inner conductor contacts.
4.6.13.1 General procedure. The apparatus shall be assembled as shown on figure 2. The contacts,
C1 – C2, shown on the figure represent the mating contacts upon which millivolt drop tests are to be
conducted.
a.
b.
c.
d.
e.
f.
g.
h.
i.
Remove contacts C1 – C2 from the measuring circuit.
Close switch SW.
Adjust R2 for a millivoltmeter (mVm) reading of 50 millivolts.
Connect contacts C1 – C2 to the measuring circuit and mate.
Check to see that mVm drops significantly prior to opening switch in (f).
Open switch SW.
Adjust R1 for a circuit current (A) of one ampere.
Measure the millivolt drop across contacts C1 – C2 and call this “e”.
Compute contact resistance Contact resistance (milliohms) = e millivolts ÷ one ampere.
FIGURE 2. Diagram for contact resistance.
21
MIL-PRF-39012E
4.6.14 Dielectric withstanding voltage (see 3.17). Connectors shall be tested in accordance with
method 301 of MIL-STD-202. The following details shall apply:
a. Special preparation or conditions.
(1) The maximum relative humidity shall be 50 percent. When facilities are not
available at this test condition, connectors shall be tested at room ambient relative
humidity. In case of dispute, if the test has been made at room ambient relative
humidity, retest shall be made at 50 percent maximum relative humidity.
(2) The center contact of plug connectors and receptacle connectors shall be
positioned in such a manner as to simulate actual assembly conditions.
(3) Precautions shall be taken to prevent air-gap voltage breakdowns.
(4) The voltage shall be metered on the high side of the transformer.
b. Magnitude of test voltage (see 3.1): The voltage shall be instantaneously applied.
c.
Nature of potential: Alternating current.
d. Points of application of test voltage: Between the center contact and body.
4.6.15 Vibration (see 3.18). A complete connector assembly shall be mounted as shown on figure 3
and vibrated in accordance with test condition B, method 204, MIL-STD-202. The center and outer
contacts shall be connected to a suitable monitoring device. Suitable coaxial cable or wire as
applicable, using the normal connecting devices of the connector and clamped as shown on figure 3,
shall be used. At least 100 milliamperes shall be flowing through each set of contacts. Contacts may
be connected in series. The connector shall be mounted by its normal mounting device and engaged
by its normal coupling device. No safety wire shall be used. Cable to cable connectors may be held
to the jig on figure 3 by a suitable clamp on one half of the connector assembly. The following
conditions shall apply:
a. Test condition letter (see 3.1).
b. Continuity shall be monitored during vibration with a detector capable of detecting
interruptions of 1 µs duration or longer, or as specified at 100 milliamperes.
22
MIL-PRF-39012E
Inches
.12
.250
3.50
4.45
8.00
mm
3.05
6.35
88.9
113.03
203.2
FIGURE 3. Vibration testing set-up
4.6.16 Shock (specified pulse) (see 3.19). The connector shall be mated with its mating connector
(see 3.1) and subjected to method 213 of MIL-STD-202. The following exceptions and details shall
apply:
a. Receptacles and panel or bulkhead mounted connectors and adapters shall be mounted by
normal means. All other connectors and adapters shall be rigidly clamped to the vibration
table.
b. Acceleration requirements (see 3.1).
c.
Three blows in each of three mutually perpendicular planes; one of which shall be parallel
to the axis of the connector.
d. Continuity shall be monitored during shock as specified in 4.6.15(b).
e. Center contact resistance shall be measured in accordance with 4.6.13 after the shock test.
23
MIL-PRF-39012E
4.6.17 Thermal shock (see 3.20). Connectors shall be subjected to method 107 of MIL-STD-202.
The following details shall apply:
a. Test condition letter (see 3.1).
b. The contact resistance tests on the center contact shall be performed before and after the
thermal shock test and examined for mechanical damage (see 3.1).
4.6.18 Moisture resistance (see 3.21). The connector shall be mated and cabled with its mating
connector and shall be subjected to method 106, MIL-STD-202. The following exceptions and
conditions shall apply:
a. No initial measurements.
b. No load.
c.
Step 7b (vibration) shall be omitted.
d. Measurements shall be made at high humidity when specified (see 3.1).
e. The connector shall withstand the dielectric withstanding voltage specified (see 4.6.14)
after the drying period.
4.6.19 Corona level (see 3.22). The test sample shall be connected to a mating connector and
arranged in a suitable test circuit such as indicated on figure 4. Components of the test circuit shall
be corona free to the extent that a discharge of five picocoulombs or less can be measured when the
60 Hz test potential is increased to the value specified at the reduced pressure specified (see 3.1).
The type of cable and length of cable used shall be as specified (see 3.1). No grease or similar
compounds shall be used in or on the test item. After the sample is purged of air, the 60 Hz voltage
shall be slowly increased until the detector, operated at a sensitivity of five picocoulombs, indicates a
sustained corona discharge. The voltage shall then be decreased until corona is at the five
picocoulombs level or less. The latter value is the corona level of the connector under test. The
contractor may, at his own option, use a corona detector (which has been approved by the
Government) for performing the test in lieu of the test set up on figure 4.
24
MIL-PRF-39012E
C – Corona free coupling capacitor (see note 1).
D – Discharge display.
L1 – Input line filter (see note 2).
L2 – 10-50 KHz detector input filter.
A – Detector amplifier.
T1 – 0-130 V variable transformer.
T2 – High voltage transformer (corona free – less than 5 picocoulombs).
V – Voltmeter.
NOTES:
1. Equal to or greater than total circuit capacitance.
2. 100 dB 14 KHz to 10 GHz.
FIGURE 4. Equipment and schematic for measuring corona level.
25
MIL-PRF-39012E
4.6.20 RF high potential withstanding voltage (see 3.23). Connectors shall be mated with their
mating connectors (see 3.1) and approximately 2 inches of their standard cable (see 3.1)
appropriately attached. This assembly shall then be inserted into the high impedance circuit as
shown on figure 5, or equivalent, and instantaneously subjected to the RF voltage and frequency
specified (see 3.1) between the center contact and body of the connectors. The duration of the test
shall be 1 minute. The RF voltage source shall be frequency stabilized and have an approximate
pure sine wave output with minimum harmonic content. Means shall be provided to indicate
disruptive discharge and leakage current. The maximum leakage current shall be as specified (see
3.1).
FIGURE 5. Circuit diagram for RF high potential withstanding voltage.
4.6.21 Cable retention force (see 3.24). When specified (see 3.1), the connector shall be assembled
to its standard mating test cable. The connector shall be firmly fixed and a movable sleeve attached
to the cable. The sleeve is then moved longitudinally away from the fixed connector gradually and in
such a manner that the cable remains unbent and untwisted. A scale for measuring the retention
force (see 3.1) shall be attached to the sleeve. The force shall be held for 30 seconds minimum. The
assembly shall then be examined for mechanical failure, loosening, or rupture and tested for
continuity using a suitable test method. When specified (see 3.1), a torque shall be applied to the
cable about its axis in each direction relative to the connector at the location and to the torque value
given on the detail specification sheet. The cable (flexible types only) shall then be bent at a radius of
10 times the diameter of the cable starting at the connectors at an angle of 90º ± 5º from the axis of
the connector, then reversed 180º ± 10º. Repeat this procedure four times, then retest and
reexamine as outlined above.
4.6.22 Coupling mechanism retention forces (see 3.25). The connector body and coupling
mechanism shall be respectively secured to the lower and upper jaws of a tensile tester in an
appropriate manner. A tensile load shall be applied at a rate of approximately 100 pounds/minute up
to the force as specified and held at that value for one minute (see 3.1). During the one minute of
steadily applied force, the coupling mechanism shall be rotated with respect to the connector body,
two full revolutions in each direction.
26
MIL-PRF-39012E
4.6.23 RF leakage (see 3.26). The mating connector pair to be tested shall be assembled as shown
on figure 6 and tested as shown on figure 7. (The procedure for determining the dimensions of the
cavity on figure 7 may be found in A.3.1 of the appendix). The close fitting brass tubing shall be
machined to thread into connector in lieu of compression nut (see 3.1). This test setup between 500
MHz and 11 GHz, shall have a dynamic range from –20 dBm to better than –100 dBm or a difference
of 90 dB. Using +20 dBm RF source with 10 dB isolation, an additional 30 dB range can be obtained
by use of attenuator pads or a step attenuator producing a total range of 120 dB. The shortening
plunger is adjusted to produce a maximum reading in the detector with the triaxial assembly inserted.
The insertion loss caused by the insertion of the triaxial assembly adjusted as shown is a measure of
the total leakage of the mated connector pair both at its interface as well as at the clamping points to
both cables.
Reference
“RF Leakage Characteristics of Popular Coaxial Cables and Connectors, 500 MS to 7.5 GHz”, by J.
Zorzy and RF Muehlberger, in the Microwave Journal, November 1961, pp 80-86.
4.6.24 RF insertion loss (see 3.27). The connector shall be tested as shown on figure 8. Insertion
loss of a mated connector pair is defined as the increase of a loss due to insertion of a mated
connector pair in a cable; this includes the reflection losses to the cable and the dissipating losses in
the pair. First insert cable assembly number 1 and tune out its input VSWR by means of tuner
number 4 and balance setup. Then insert the cable assembly number 2 which includes the connector
pair under test. With tuner number 4 in the same position and the electrical length of the cable
assembly the same as that of number 1, record increase of insertion loss; add to this as a correction
the cable loss of the removed section due to the length ∆L1 + ∆L2 at this frequency. The sum of the
increase and the correction is the insertion loss of the connector pair. Use of alternate test methods
may be approved by the qualifying activity.
27
MIL-PRF-39012E
FIGURE 6. Connector assembly for RF leakage test.
FIGURE 7. RF leakage test set-up.
28
MIL-PRF-39012E
Inches
3.50
4.50
7.00
9.00
mm
88.9
114.3
177.8
228.6
FIGURE 8. Method of insertion loss measurement of rated connector pair.
29
MIL-PRF-39012E
4.6.25 Safety wire hole pullout (see 3.32). A single strand of safety wire shall be looped through the
safety wire hole and secured to itself. Forces of 15 pounds (67 Newtons) minimum shall be applied
to the safety wire pulling away from the connector. One pull shall be parallel to the connector axis
and one pull perpendicular to the connector axis (see figure 9). The safety wire shall be corrosion
resistant steel .020 inch diameter (24 gauge) or .015 inch diameter, (27 gauge) in accordance with
NASM20995. This test is to be conducted under static conditions. All holes are to be tested
individually.
FIGURE 9. Safety wire hole pullout procedure.
5. PACKAGING
5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified in the
contract or order (see 6.2). When actual packaging of materiel is to be performed by DoD or inhouse contractor personnel, these personnel need to contact the responsible packaging activity to
ascertain packaging requirements. Packaging requirements are maintained by the Inventory Control
Point's packaging activities within the Military Service or Defense Agency, or within the Military
Service System Commands. Packaging data retrieval is available from the managing Military
Department’s or Defense Agency’s automated packaging files, CD-ROM products, or by contacting
the responsible packaging activity.
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful, but is not
mandatory.)
6.1 Intended use. Connectors and fittings covered by this specification are intended for use in
radiofrequency application up to the frequency specified (see 3.1).
6.2 Acquisition requirements. Acquisition documents should specify the following:
a. Title, number, and date of this specification.
b. Title, number and date of the applicable detail specification.
30
MIL-PRF-39012E
c.
The complete PIN of the connector or fitting ordered.
d. For category B connectors, the special tools which are to be used in the assembly of the
connectors.
6.2.1 Packaging. See 5.1.
6.3 Qualification. With respect to products requiring qualification, awards will be made only for
products which are, at the time of award of contract, qualified for inclusion in the Qualified Products
List QPL N0. 39012 whether or not such products have actually been so listed by that date. The
attention of the contractors is called to these requirements, and manufacturers are urged to arrange
to have the products that they propose to offer to the Federal Government tested for qualification in
order that they may be eligible to be awarded contracts or orders for the products covered by this
specification. Information pertaining to qualification of products may be obtained from Defense
Supply Center Columbus (DSCC-VQ), P.O. Box 3990, Columbus, Ohio 43218-3990 or email at
[email protected] .
6.4 References to superseded specifications. All the requirements of MIL-PRF-39012E are
interchangeable with those of MIL-PRF-39012D, therefore, previously existing documents (OEM
drawings, etc.) referencing MIL-PRF-39012D need not be changed.
6.5 Cross-reference of PINs. For the substitutability relationship of items covered by this
specification and items covered by superseded documents, see table VIII. However, all connectors in
stock may be considered interchangeable with the new PIN for a period of 1 year from the effective
date of this specification.
6.6 Engineering parameters. The parameters of nominal impedance, voltage rating, frequency
range, and temperature range will be as specified.
6.7 Installation of category “B” connectors. Field replaceable connectors for category “B” are those
specified on the latest issue of the Qualified Products List and are to be adequate as a replacement
without rework of the connector. The equipment parts list is to indicate the appropriate connector that
will be used for the service replacement of a category “B” connector.
6.8 Changes from previous issue. Marginal notations are not used in this revision to identify
changes with respect to the previous issue due to the extent of the changes.
31
MIL-PRF-39012E
TABLE VIII. Cross-reference information.
Superseded PIN
M39012/
01-0001
01-0002
01-0003
01-0004
01-0025
02-0001
02-0002
02-0004
02-0005
02-0031
02-0001
03-0001
03-0002
05-0001
16-0001
16-0002
16-0003
16-0011
16-0018
17-0001
17-0002
17-0003
17-0011
17-0018
18-0001
18-0002
18-0003
18-0011
18-0018
19-0001
19-0002
19-0010
19-0011
19-0018
20-0001
36-0013
36-0014
36-0011
38-0001
38-0002
38-0009
39-0001
39-0006
39-0007
40-0001
40-0002
40-0003
40-0004
40-0005
Superseding PIN
M39012/
01-0101
01-0005
01-0015
01-0104
01-0125
02-0101
02-0003
02-0104
02-0006
02-0131
02-0132
03-0101
03-0012
05-0101
16-0101
16-0102
16-0103
16-0111
16-0118
17-0101
17-0102
17-0103
17-0111
17-0118
18-0101
18-0102
18-0103
18-0111
18-0118
19-0101
19-0102
19-0110
19-0001
19-0118
20-0101
36-0019
36-0020
36-0017
38-0010
38-0011
38-0012
39-0101
39-0106
39-0107
40-0023
40-0024
40-0025
40-0026
40-0027
Superseded PIN
M39012/
20-0006
26-0001
26-0002
26-0003
26-0004
26-0017
27-0001
27-0003
27-0004
27-0017
28-0001
28-0002
28-0003
28-0004
28-0017
29-0001
29-0002
29-0003
29-0004
29-0017
30-0001
30-0002
30-0003
30-0004
30-0017
30-0018
35-0001
35-0002
35-0003
35-0004
35-0005
35-0015
36-0001
36-0002
36-0012
59-3004
59-4004
59-3005
59-4005
UG-18E/U
UG-19E/U
UG-20E/U
UG-21G/U
UG-22/U
UG-23/U
UG-58/U
UG-88/U
UG-89/U
UG-159D/U
32
Superseding PIN
M39012/
20-0108
26-0101
26-0102
26-0103
26-0104
26-0117
27-0101
27-0103
27-0104
27-0117
28-0101
28-0102
28-0103
28-0104
28-0117
29-0101
29-0102
29-0103
29-0104
29-0117
30-0101
30-0102
30-0103
30-0104
30-0117
30-0118
35-0016
35-0017
35-0018
35-0019
35-0020
35-0021
36-0015
36-0016
35-0018
59-3009
59-4009
59-3010
59-4010
01-0101
02-0104
02-0101
01-0005
02-0006
02-0003
04-0002
16-0101
17-0101
03-0101
MIL-PRF-39012E
TABLE VIII. Cross-reference information – Continued.
Superseded PIN
M39012/
55-3001
55-4001
55-3002
55-4002
55-3003
55-4003
55-3004
55-4004
55-3005
55-4005
56-3001
56-4001
56-3002
56-4002
56-3003
56-4003
56-3004
56-4004
56-3005
56-4005
57-3001
57-4001
57-3002
57-4002
57-3003
57-4003
57-3004
57-4004
57-3005
57-4005
57-3001
58-4001
58-3002
58-4002
58-3003
58-4003
58-3004
58-4004
58-3005
58-4005
59-3001
69-4001
59-3002
59-4002
59-3003
59-4003
UG-1186A/U
UG-1187A/U
UG-1392/U
UG-1393/U
UG-1394/U
UG-1395/U
Superseding PIN
M39012/
55-3006
55-4006
55-3007
55-4007
55-3008
55-4008
55-3009
55-4009
55-3010
55-4010
56-3006
56-4006
56-3007
56-4007
56-3008
56-4008
56-3009
56-4009
56-3010
56-4010
57-3006
57-4006
57-3007
57-4007
57-3008
57-4008
57-3009
57-4009
57-3010
57-4010
57-3006
57-4006
58-3007
58-4007
58-3008
58-4008
58-3009
58-4009
58-3010
58-4010
59-3001
59-4001
59-3002
59-4002
59-3003
59-4003
02-0003
02-0006
44-2001
44-2002
48-2001
46-2001
Superseded PIN
M39012/
UG-160E/U
UG-167F/U
UG-204D/U
UG-260/U
UG-261/U
UG-262/U
UG-290/U
UG-291/U
UG-568/U
UG-569/U
UG-570/U
UG-571/U
UG-572/U
UG-573C/U
UG-594C/U
UG-625/U
UG-626C/U
UG-627/U
UG-629/U
UG-630/U
UG-631/U
UG-633/U
UG-680/U
UG-704/U
UG-705/U
UG-706/U
UG-707C/U
UG-708C/U
UG-709/U
UG-710/U
UG-711C/U
UG-909/U
UG-910/U
UG-911/U
UG-912/U
UG-913/U
UG-935D/U
UG-940C/U
UG-941C/U
UG-1033/U
UG-1055/U
UG-1056/U
UG-1094/U
UG-1098/U
UG-1174/U
UG-1185A/U
UG-1767/U
UG-1768/U
UG-1769/U
UG-1770/U
UG-1771/U
UG-1773/U
33
Superseding PIN
M39012/
03-0012
01-0104
01-0015
16-0102
17-0102
18-0101
22-0001
18-0102
12-0001
14-0001
11-0002
08-0001
07-0001
06-0002
05-0101
12-0001
06-0001
15-0001
08-0002
11-0001
09-0001
07-0002
04-0001
09-0002
14-0002
13-0001
06-0003
06-0005
15-0002
10-0001
06-0004
19-0101
19-0102
24-0001
24-0002
20-0101
02-0032
02-0031
01-0125
16-0103
18-0103
17-0103
21-0002
23-0001
23-0002
01-0005
09-0003
09-0004
10-0002
10-0003
10-0004
11-0004
MIL-PRF-39012E
TABLE VIII. Cross-reference information – Continued.
Superseded PIN
M39012/
UG-1396/U
UG-1397/U
UG-1398/U
UG-1399/U
UG-1460/U
UG-1461/U
UG-1462/U
UG-1463/U
UG-1464/U
UG-1465/U
UG-1466/U
UG-1467/U
UG-1468/U
UG-1487/U
UG-1533/U
UG-1537A/U
UG-1619/U
UG-1696/U
UG-1697/U
UG-1698/U
UG-1700/U
UG-1707/U
UG-1708/U
UG-1746/U
UG-1748/U
UG-1749/U
UG-1750/U
UG-1751/U
UG-1752/U
UG-1753/U
UG-1754/U
UG-1755/U
UG-1756/U
UG-1758/U
UG-1759/U
UG-1761/U
UG-1762/U
UG-1763/U
UG-1765/U
Superseding PIN
M39012/
46-2002
45-2001
45-2002
49-2001
73-0001
75-0001
74-0001
76-0001
77-0002
73-0002
75-0002
74-0002
76-0002
01-0015
47-2001
03-0012
77-0001
02-0015
02-0016
02-0017
03-0004
05-0002
05-0003
06-0006
06-0007
06-0008
06-0009
06-0010
06-0011
06-0012
07-0003
07-0004
07-0005
07-0007
07-0008
08-0003
08-0004
08-0005
08-0007
Superseded PIN
M39012/
UG-1774/U
UG-1775/U
UG-1776/U
UG-1777/U
UG-1779/U
UG-1780/U
UG-1785/U
UG-1786/U
UG-1787/U
UG-1788/U
UG-1789/U
UG-1790/U
UG-1791/U
UG-1792/U
UG-1793/U
UG-1794/U
UG-1795/U
UG-1796/U
UG-1797/U
UG-1798/U
UG-1799/U
UG-1800/U
UG-1801/U
UG-1802/U
UG-1803/U
UG-1804/U
UG-1805/U
UG-1806/U
UG-1807/U
UG-1808/U
UG-1809/U
UG-1810/U
UG-1811/U
UG-1812/U
UG-1813/U
UG-1814/U
UG-1817/U
UG-1819/U
34
Superseding PIN
M39012/
11-0005
11-0006
11-0007
11-0008
15-0003
15-0004
16-0004
16-0005
16-0006
16-0007
16-0008
16-0010
16-0009
18-0010
18-0009
17-0004
17-0005
17-0006
17-0007
17-0008
17-0010
17-0009
18-0008
18-0004
18-0005
19-0003
19-0004
19-0005
19-0006
19-0007
19-0009
19-0008
18-0007
20-0002
20-0003
18-0006
10-0014
03-0011
MIL-PRF-39012E
TABLE VIII. Cross-reference information – Continued.
Hardware to connectors
CW-123A/U
CW-155A/U
CW-159/U
MX-1286/U
MX-1142A/U
25-0006
25-0015
25-0016
25-0017
25-0010
25-0008
25-0009
25-0011
25-0012
MX-195/U
CW-282/U
MX-913/U
25-0013
25-0001
25-0002
25-0003
25-0004
25-0005
MX-1143A/U
MX-1144/U
6.9 Subject term (key word) listing.
Copper Beryllium
Silver
Nickel
Brass
6.10 Environmentally preferable material. Environmentally preferable materials should be used to the
maximum extent possible to meet the requirements of this specification. Table IX lists the
Environmental Protection Agency (EPA) top seventeen hazardous materials targeted for major usage
reduction. Use of these materials should be minimized or eliminated unless needed to meet the
requirements specified herein (see section 3).
TABLE IX. EPA top seventeen hazardous materials.
Benzene
Cadmium and Compounds
Carbon Tetrachloride
Chloroform
Chromium
Cyanide and Compounds
Dichloromethane
Lead and Compounds
Mercury and Compounds
Methyl Ethyl Ketone
Methyl Isobutyl Ketone
Nickel and Compounds
35
Tetrachloroethylene
Toluene
1,1,1-Trichloroethane
Trichloroethylene
Xylenes
MIL-PRF-39012E
APPENDIX A
ADDITIONAL INFORMATION ON TEST PROCEDURES
A.1 SCOPE
A.1.1 Scope. This appendix is a mandatory part of this specification. The information contained
herein is intended for compliance. This appendix is to provide additional information to the user of
this specification in performing the voltage standing wave ratio, RF leakage, and insertion loss tests.
A.2 TEST TYPES
A.2.1 Voltage standing wave ratio (see 4.6.11).
A.2.1.1 Test connector. The standard test-connector interface shall be in accordance with
MIL-STD-348. The standard test connector impedance shall be 50 ± 0.5 ohms.
A.3 MEASUREMENTS
A.3.1 RF leakage (see 4.6.23).
A.3.1.1 Measurement technique. The measurement of the leakage from connectors is performed by
collecting the leakage energy in a coaxial system surrounding the leakage source. An outline of the
instrumentation is shown on figure 7. The device from which leakage is to be measured is
incorporated on a uniform transmission line which is terminated in a matched load. The matched
termination simplifies both the measurement procedure and data reduction. This complete coaxial
system is embodied within a cylinder which forms, externally, a second coaxial system. The second
coaxial system is terminated at one end in an adjustable short-circulating plunger and at the other in a
tapered transition terminated in a matched detector.
For direct leakage measurements the adjustable short circuit serves several purposes.
The short-circuit position is adjusted to assure that an adequately low impedance appears behind the
equivalent leakage generator. A matched termination can be substituted, but the resulting 6-dB loss
cannot be tolerated in some cases. In addition, if the leakage source is directional, as it indeed is for
connectors with multiple leakage, it is possible for the leakage to be directed to this termination at
some frequencies and not collected by the detector. For surface transfer-impedance measurements
on connectors with leakage from more than one point in the connector, however, a matched
termination is desirable in order to simplify the transformation of the measured data to absolute
transfer impedance data. This is not needed to make relative comparisons in this test.
The equivalent leakage generator, in general, can have field components in the radial, axial, and
circumferential* directions. Furthermore, these components are not necessarily circularly symmetric.
Locally, TE, TM, and TEM modes can all exist, and in fact, for complete leakage measurements, the
detector should couple to all but the measurement is more complex in this case. The excitation of the
outer coaxial line, however, is believed to be principally TEM, since the currents in the internal line are
predominantly axial and symmetric. It is however, possible to have a symmetrical leakage current
which can generate the above mentioned modes. It is recommended that all measurements be made
below the frequency that the higher order modes can propagate in the outer coaxial line.
The characteristic impedance of the outer coaxial line of the tri-axial system, which is formed with the
inner conductor, should be matched to the detector. 50-ohm coaxial circuits are generally desired for
convenience.
36
MIL-PRF-39012E
APPENDIX A
*NOTE: The circumferential E field component is not usually present in axially symmetric
components.
The leakage power ratio is defined here as the ratio of the power detected to a 50-ohm detector at the
output of the tri-axial unit to the power flowing through the internal 50-ohm connector or cable system.
It is basically the attenuation through the tri-axial system. This definition appears arbitrary in the
sense that 50 ohms is an arbitrary load impedance. However, since the leakage source impedance is
comparatively low, the voltage at the detector is essentially the open circuit leakage voltage. The ratio
of the input voltage to the leaky device to this output voltage is an absolute leakage quantity, as is the
measured power ratio, which is identically equal to the square of this voltage ratio.
The surface transfer impedance is obtained from this ratio as follows:
The surface transfer impedance is.
Z11=e2
I1
Where I1=Current flowing in internal line and
e2=Equivalent leakage voltage in external line.
In the connector leakage case, considering the equivalent leakage generator to be e2 with an
extremely low source impedance, this voltage e2 appears at detector terminals, and the adjustable
short circuit assures this. For a 50-ohm transmission-line system, the input power is
2
i
501
The measured output power is:
e22
50
(1)
The measured power ratio A2 is therefore,
e22
A = 50 = e22 2
2 (50)2i
i
1
501
2
(2)
Substituting and by definition,
Z21 = e2 = 50 A
1
1
(3)
The tri-axial system was set up principally to assess the relative leakage.
37
MIL-PRF-39012E
APPENDIX A
A.3.1.2 Measurement procedure. In measuring the leakage power ratio, A2, basically a substitution
technique is employed. A matched detector system is installed at the output connector of the tri-axial
unit, and the unit is driven as shown on figure 7. In this set-up, the short circuit is adjusted to produce
a maximum indication at the detector. The detector is then connected directly to the source and the
change of attenuation required to yield the initial detector level, is measured.
The sensitivity of this system is obviously limited by the sensitivity of the detector and the power
available. A sensitive parallel IF substitution system is employed, and for the low leakage
configuration about 100 milliwatts of power is required.
The principal sources of error are attenuator errors and mismatch at the receiver (mixer) input. For
connector measurements, the error due to mismatch is directly proportional to VSWR since the
equivalent leakage source impedance is small. The indicated leakage power can vary between the
extremes. PxVSWR to P + VSWR, where P is the power that would be delivered to a matched
system. A VSWR of 2 will produce ± 3 –dB error therefore.
In advance of installing the inner coaxial system into the outer of the tri-axial system, the inner
system may be excited, and the immediate vicinity of the leakage point or associated connector and
attachment points probed with a small loop or dipole to establish how critical the mating, the
connector and joints are.
A.4 RF insertion loss (see 4.6.23).
A.4.1 The following procedure may be used when performing the insertion loss test of 4.6.24:
Assemble one 8” ± 1” long cable assembly terminated in a male and female test connector. Record
its relative electrical length. Tune out its input VSWR using tuner number 4. Do not disturb tuner.
For N, C, SC use M17/75-RG214 and “N” test connectors. For BNC, TNC, and TPS, use solid
copper shield cable equivalent of M17/111-RG303 (Coaxitube number 1163.T1403-20 of Precision
Tube Co.) and TNC connectors. Measure insertion loss L1 of tuner number 4 and test cable.
Insert the connector pair to be tested in the middle, remove enough so that the electrical length is the
same as above within 0.05 cm, record ∆l1 + ∆l2 the total length of dielectric removed; keep tuner
number 4 in the same position as above. Measure insertion loss L2 of tuner number 4 and test cable
including connector pair.
Measure attenuation of 50 feet of test cable and compute loss
α per inch Lc = L2 – L1 + a (∆l1 = ∆l2).
38
MIL-PRF-39012E
APPENDIX B
ADDITIONAL INFORMATION ON CABLE GROUPINGS
B.2 SCOPE
B.2.1 Scope. This appendix is not a mandatory part of the specification. The information contained
herein is intended for guidance only. This appendix is to provide additional information in determining
the cable to connector combinations available.
B.2.2 Cable groupings. See notes at end of listing.
Group I
Cable M17/
Zo
F
Dielectric
93-RG178
169-00001
50
50
3
0.4
PTFE
PTFE
Group: I
Category: A, B
*
X
Group II
II
A
119-RG174
50
1
PE
X
173-00001
50 0.4
PE
X
196-00001 1/ 50
1
PTFE
X
113-RG316
50
3
PTFE
*
172-00001
50 0.4
PTFE
X
94-RG179
75
3
PTFE
X
1/ This cable is intended for low smoke applications.
Cable M17/
Zo
F
Dielectric
Group
Category
IIa
C
X
X
X
*
X
IIb
C
*
Group III
Cable M17/
Zo
F
Dielectric
152-00001
50
12.4
PTFE
Group: III
Category: A, C
*
Group IV
Cable M17/
Zo
F
Dielectric
Group: IV
Category: A, C, D
54-RG122
50
1
PE
*
157-00001
50 0.4
PE
X
187-00001 1/ 50
1
PE
X
198-00001 1/ 50 0.4
PE
X
1/ This cable is intended for low smoke applications.
Group V
Cable M17/
Zo
F
Dielectric
95-RG180
95
3
PTFE
39
Group: V
Category: A, C, D
*
MIL-PRF-39012E
APPENDIX B
Group VI
VI
A
X
X
X
X
X
X
X
X
X
X
X
X
*
X
VIa
C, D
X
X
X
X
*
X
VII
A
29-RG58
75 1
PE
X
184-00001 1/ 75 1
PE
X
110-RG302
75 3
PTFE
*
30-RG062
93 1
PE
X
185-00001 1/ 93 1
PE
X
97-RG210
93 3
PTFE
X
90-RG71
93 1
PE
X
195-00001 1/ 93 1
PE
X
1/ This cable is intended for low smoke applications.
VIIa
C
X
X
*
X
X
X
Cable M17/
Zo
F
Dielectric
Group
Category
PE
1
50
28-RG058
PE
50 0.4
155-00001
PE
1
183-00001 1/ 50
PE
197-00001 1/ 50 0.4
PTFE
3
50
111-RG303
PTFE
50 0.4
170-00001
PTFE
50 12.4
60-RG142
PTFE
50 0.4
158-00001
PE
50 12.4
84-RG223
PE
50 0.4
167-00001
PE
194-00001 1/ 50 12.4
PE
200-00001 1/ 50 0.4
PTFE
50 12.4
128-RG400
PTFE
50 0.4
175-00001
1/ This cable is intended for low smoke applications.
VIb
C, D
X
X
X
X
X
X
*
X
Group VII
Cable M17/
Zo
F
Dielectric
Group
Category
Group VIII
Cable M17/
Zo
F
Dielectric
Group: VIII
Category: A, C
2-RG6
75
3
PE
X
180-00001 1/ 75
3
PE
X
73-RG212
50
11
PE
X
162-00001 1/ 50 0.4
PE
X
188-00001 1/ 50
11
PE
X
199-00001 1/ 50 0.4
PE
X
112-RG304
50 12.4
PTFE
*
171-00001
50 0.4
PTFE
X
1/ This cable is intended for low smoke applications.
40
VIIb
C
*
X
MIL-PRF-39012E
APPENDIX B
Group IX
Cable M17/
Zo
F
Dielectric
92-RG115
168-00001
50
50
12.4
0.4
PTFE
PTFE
Group: IX
Category: A
*
X
Group X
Cable M17/
Zo
F
Dielectric
6-RG11
181-00001 1/
62-RG144
65-RG165
159-00001
74-RG213
189-00001 1/
163-00001
75-RG214
190-00001 1/
164-00001
86-00001
127-RG393
174-00001
77-RG216
191-00001 1/
75
75
75
50
50
50
50
50
50
50
50
50
50
50
75
75
1
1
3
3
0.4
1
1
0.4
11
11
0.4
0.4
11
0.4
3
3
PE
PE
PTFE
PTFE
PTFE
PE
PE
PE
PE
PE
PE
PTFE
PTFE
PTFE
PE
PE
Group
Category
X
A
X
X
X
X
X
X
X
X
X
X
X
X
*
X
X
X
Xa
C, D
Xb
C, D
Xc
C
X
X
X
*
X
X
X
X
X
X
X
*
X
X
1/ This cable is intended for low smoke applications.
Group XI
Cable M17/
Zo
F
Group: XI
Category: A
74-RG215
50 1
PE
*
PE
X
189-00002 1/ 50 1
1/ This cable is intended for low smoke applications.
Dielectric
Group XII
Cable M17/
Zo
F
Dielectric
Group: XII
Category: A, C
78-RG217
50
3
PE
*
165-00001
50 0.4
PE
X
192-00001 1/ 50
3
PE
X
1/ This cable is intended for low smoke applications.
41
Xd
C
*
X
MIL-PRF-39012E
APPENDIX B
Group XIII
Cable M17/
Zo
F
Dielectric
72-RG211
161-00001
50
50
1
0.4
PTFE
PTFE
Group: XIII
Category: A
*
X
Group XIV
Cable M17/
Zo
F
Dielectric
Group: XIV
Category: A
79-RG218
50
1
PE
*
166-00001
50 0.4
PE
X
193-00001 1/ 50
1
PE
X
1/ These cables are intended for low smoke applications.
Group XV
Cable M17/
129-RG401
129-00001
130-RG402
130-00001
130-00002
130-00003
130-00004
130-00005
130-00006
130-00007
133-RG405
133-00001
133-00002
133-00003
133-00004
133-00005
133-00006
133-00007
133-00008
133-00009
133-00010
133-00011
151-00001
151-00002
154-00001
154-00002
Zo
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
F
18
18
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
OD
(mm)
6.35
6.35
3.58
3.58
3.58
3.58
3.58
3.58
3.58
3.58
2.18
2.18
2.18
2.18
2.18
2.18
2.18
2.18
2.18
2.18
2.18
2.18
1.19
1.19
0.86
0.86
Dielectric
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
PTFE
42
XV
X
X
XVI
Groups
XVII XVIII
XIX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
MIL-PRF-39012E
APPENDIX B
mm
0.86
1.19
2.18
3.58
6.35
Inches
.034
.047
.086
.141
.250
NOTES:
1. Zo denotes nominal impedance in ohms.
2. F denotes the upper frequency limit in GHz. For cables with 0.4, the structural return loss and
the power handling capability are not specified. Attenuation is tested only at 0.4 GHz.
3. PE denotes a polyethylene dielectric. PTFE denotes a polytetrafluoroethylene dielectric.
4. Dimensions are in millimeters. Inch-pound equivalents are given for information only.
5. * denotes preferred cable.
CONCLUDING MATERIAL
Custodians:
Army – CR
Navy – EC
Air Force – 11
NASA – NA
DLA - CC
Preparing activity:
DLA - CC
(Project 5935-4615-000)
Review activities:
Army – AR, AT, MI
Navy – AS, MC, OS, SH
Air Force – 19, 99
NOTE: The activities listed above were interested in this document as of the date of this document.
Since organizations and responsibilities can change, you should verify the currency of the information
above using the ASSIST Online database at http://assist.daps.dla.mil.
43