power cables / iec 60502-1
Transcription
power cables / iec 60502-1
INDEX 1 Introduction Preface General information Definitions Page 1 Page 3 Page 4 2 Power & Control Cables to IEC Standard Power Cable 0.6/1 kV PVC Insulated, Unarmoured Single-Core Cables 0.6/1 kV PVC Insulated, Unarmoured Multi-Core Cables 0.6/1 kV PVC Insulated, Armoured Multi-Core Cables 0.6/1 kV XLPE Insulated, Unarmoured Single-Core Cables 0.6/1 kV XLPE Insulated, Unarmoured Multi-Core Cables 0.6/1 kV XLPE Insulated, Armoured Multi-Core Cables Control Cable Page 5 Page 9 Page 13 Page 21 Page 25 Page 29 0.6/1 kV PVC Insulated, Unarmoured Control Cables Page 37 0.6/1 kV PVC Insulated, Shielded Control Cables Page 41 0.6/1 kV PVC Insulated, Armoured Control Cables Page 45 3 Power & Control Cables to BS Standard Power Cable 600/1000 V PVC Insulated, Steel Wire Armoured Multi-Core Cables 600/1000 V XLPE Insulated, Unarmoured Single-Core Cables 600/1000 V XLPE Insulated, Steel Wire Armoured Multi-Core Cables Control Cable 600/1000 V PVC Insulated, Steel Wire Armoured Control Cables 4 Cables For Special Applications Lead Sheathed Cables Low Smoke Halogen Free Cables Other Types / Characteristics 5 Technical Data Page 53 Page 57 Page 61 Page 65 Page 67 Page 67 Page 68 Recommendations Page 69 Material properties Page 73 Short circuit current Page 80 Formulas Derating factors Voltage drop Page 71 Page 74 Page 83 Coding Key Page 85 Selection of conductor cross-section Page 86 Conversion table Page 87 Certificates Product Range Contact Details Page 88 Page 89 Page 91 Low Voltage Power and Control Cables Preface Low Voltage Power, Control and Special Application Cables are used in various indoor and outdoor applications in power plants, industries, switchgears, and in railways and traffic signaling systems. Our products conform to various IEC and BS standards. They are tested at leading international laboratories and are approved by many utility companies, ministries and major industries. brand is the manifestation of ’s constant endeavor for providing a comprehensive range of construction materials to satisfy its customers with products of the highest quality standard and safety coupled with prompt services. Our cables factory is one of the major industrial units in the ultramodern, fully-integrated Industrial Complex. Industries Industrial Complex – located in Riyadh – houses several industrial units for manufacturing medium/low voltage products, wires and cables, transformers, wooden reels (for coiling cables) and PVC compounds (for insulation and jacketing materials). Apart from the manufacturing units, the Industrial Complex also houses a commercial zone, a data/communication center and other facilities. The Industrial Complex is symbolic of growth representing its bright future. ’s consistent Group Overview From its headquarters in Riyadh, Saudi Arabia, operates a fully-integrated global network of manufacturing facilities, design & development centers, and branches in Dubai (UAE), Doha (Qatar), Cairo (Egypt), Damascus (Syria), Chennai (India) and many other countries. Our major businesses and services include: Electrical Manufacturing, Electrical Construction, Marketing and Distribution, Building Industry, Real Estate Development, Information Technology and Communication. General Information Selecting a Power Cable The following factors are important when selecting a suitable cable construction which is required to transport electrical energy from the power station to the consumer: Maximum operating voltage Insulation level Frequency Load to be carried Magnitude and duration of possible load Voltage drop Length of line Mode of installation, either underground or in air Chemical and physical properties of soil Max. and min. ambient air temperature and soil temperature Specification and requirements to be met Standards The cables described in this catalogue are all standard types, and their performance has been proved in operation. Construction and tests are in accordance with the recommendations of IEC or BS publications where applicable. Power cables in accordance with other standards ( VDE, NEMA, ICEA ) can be manufactured upon a customer’s request. Weights and Dimensions Weights and dimensions characteristics are approximate and any deviations are due to manufacturing tolerance. Jacket Marking Standard embossed outer jacket marking consisting of: 1. 2. 3. 4. 5. 6. 3 Name of manufacturer “ CABLES” Type designation, size of conductor, rated voltage “ELECTRIC CABLES” Year of manufacture Continuous length marking every meter Any special part number, on request Definitions Definitions of Dimensional Values 1. Nominal value Value by which a quantity is designed and which is often used in tables. Usually, in IEC standard, nominal values give rise to values to be checked by measurements taking into consideration the specified tolerances. 2. Approximate value Value which is neither guaranteed nor checked; It is used, for example, for the calculation of other dimensional values. 3. Median value When several test results have been obtained and sorted in an ascending or descending order, the median value is the middle value if the number of available values is odd, and the mean of the two middle values if the number of available values is even. 4. Fictitious value Value calculated according to the “fictitious method” described in Annex. A of IEC 60502-1. Definitions Concerning Tests 1. Routine tests Tests made by the manufacturer on each manufactured length of cable to check that each length meets the specified requirements. 2. Sample tests Tests made by the manufacturer on samples of completed cable or components taken from a completed cable, at a specified frequency, so as to verify that the finished product meets the specified requirements. 3. Type tests Tests made before supplying on a general commercial basis, a type of cable covered by this standard, in order to demonstrate satisfactory performance characteristics to meet the intended application. These tests are of such a nature that, after they have been made, they need not be repeated, unless changes are made in the cable materials or design or manufacturing process, which might change the performance characteristics. 4. Electrical tests after installation Tests made to demonstrate the integrity of the cable and its accessories after installation. Power Cables To IEC Standard Single-Core Cables, with Stranded Circular Copper Conductors, PVC Insulated and PVC Sheathed CONSTRUCTION Conductor : Plain annealed stranded circular copper conductor, as per Class 2 of IEC 60228. Insulation : An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 ºC at normal operation to IEC 60502-1. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST1 to IEC 60502-1. APPLICATION For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants and switchgears if mechanical protection is not required, or in applications where the cable is not exposed to mechanical damage. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 70 ºC - Max. admissible temperature of conductor at short circuit for 5 seconds: 160 ºC for sizes ≤ 300 mm2 140 ºC for sizes > 300 mm2 5 The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / IEC 60502-1 CU / PVC / PVC Nominal cross sectional area mm2 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 1000 0.6 / 1 kV DIMENSIONS AND WEIGHTS ELECTRICAL DATA Max. Conductor Resistance DC at 20 ºC Ω / km 4.6100 3.0800 1.8300 1.1500 0.7270 0.5240 0.3870 0.2680 0.1930 0.1530 0.1240 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283 0.0221 0.0176 AC at 70 ºC Ω / km 5.5100 3.6800 2.1700 1.3700 0.8600 0.6300 0.4600 0.3200 0.2300 0.1900 0.1500 0.1200 0.0920 0.0750 0.0590 0.0480 0.0390 0.0290 0.0250 Current Rating Laid in ground Laid in free air A 42 52 70 90 115 135 160 200 235 270 300 345 400 450 515 580 660 740 820 A 40 50 67 85 110 130 155 190 225 255 285 325 375 420 475 525 590 650 710 A 32 40 52 65 85 105 125 155 185 210 235 270 310 350 390 435 495 555 605 A 37 48 66 80 105 130 160 200 250 285 330 380 480 550 630 720 830 940 1030 A 33 42 58 75 95 125 150 190 240 275 320 370 460 530 615 700 810 920 1010 Approx. overall diameter Approx. overall weight A mm 38 7.9 Kg / km 85 115 165 230 345 445 600 805 1085 1350 1655 2030 2675 3280 4350 5355 6685 8600 10500 29 51 65 7.0 8.9 9.9 90 11.6 135 14.6 110 170 210 245 280 320 385 450 520 600 680 775 860 12.7 16.3 18.7 20.4 22.6 24.9 28.3 31.1 35.3 38.8 42.7 47.2 52.0 AES Code C212PA10100CBK51IMR C213PA10100CBK51IMR C314PA10100CBK51IMR C315PA10100CBK51IMR C316PA10100CBK51IMR C317PA10100CBK51IMR C318PA10100CBK51IMR C319PA10100CBK51IMR C345PA10100CBK51IMR C346PA10100CBK51IMR C347PA10100CBK51IMR C348PA10100CBK51IMR C349PA10100CBK51IMR C350PA10100CBK51IMR C351PA10100CBK51IMF C352PA10100CBK51IMF C353PA10100CBK51IMF C354PA10100CBK51IMF C355PA10100CBK51IMF Single-Core Cables, with Stranded Circular Aluminum Conductors, PVC Insulated and PVC Sheathed CONSTRUCTION Conductor : Stranded circular aluminium conductor, as per Class 2 of IEC 60228. Insulation : An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 ºC at normal operation to IEC 60502-1. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST1 to IEC 60502-1. APPLICATION For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants and switchgears if mechanical protection is not required, or in applications where the cable is not exposed to mechanical damage. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 70 ºC - Max. admissible temperature of conductor at short circuit for 5 seconds: 160 ºC for sizes ≤ 300 mm2 140 ºC for sizes > 300 mm2 7 The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / IEC 60502-1 AL / PVC / PVC Nominal cross sectional area mm2 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 1000 0.6 / 1 kV DIMENSIONS AND WEIGHTS ELECTRICAL DATA Current Rating Laid in ground Laid in free air Max. Conductor Resistance DC at 20 ºC Ω / km 1.9100 1.2000 0.8680 0.6410 0.4430 0.3200 0.2530 0.2060 0.1640 0.1250 0.1000 0.0778 0.0605 0.0469 0.0367 0.0291 AC at 70 ºC Ω / km 2.2900 1.4400 1.0430 0.7700 0.5330 0.3850 0.3050 0.2480 0.1980 0.1510 0.1220 0.0954 0.0751 0.0595 0.0470 0.0370 A 65 85 105 125 155 185 210 235 265 310 355 410 465 535 600 665 A 63 83 102 120 145 175 200 225 255 295 335 380 430 490 530 585 A 50 65 80 95 120 135 165 180 205 240 270 310 355 405 450 495 A 65 85 105 125 165 205 235 265 310 365 420 500 580 680 765 840 A 60 80 100 120 155 195 225 255 300 355 405 480 560 660 745 820 A 45 65 85 105 125 160 185 210 245 290 335 390 460 535 620 690 Approx. overall diameter Approx. overall weight mm Kg / km 9.9 11.6 12.7 14.6 16.3 18.7 20.4 22.6 24.8 28.3 31.1 35.3 38.8 42.7 47.2 52.0 135 185 250 295 375 500 605 725 900 1150 1420 1750 2220 2750 3450 4230 AES Code A315PA10100CBK51IMR A316PA10100CBK51IMR A317PA10100CBK51IMR A318PA10100CBK51IMR A319PA10100CBK51IMR A345PA10100CBK51IMR A346PA10100CBK51IMR A347PA10100CBK51IMR A348PA10100CBK51IMR A349PA10100CBK51IMR A350PA10100CBK51IMR A351PA10100CBK51IMR A352PA10100CBK51IMF A353PA10100CBK51IMF A354PA10100CBK51IMF A355PA10100CBK51IMF Multi-Core Cables, with Stranded Copper Conductors, PVC Insulated and PVC Sheathed CONSTRUCTION Conductor : Plain annealed stranded circular (rm) or sector shaped (sm) copper conductor, as per Class 2 of IEC 60228. Insulation : An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 ºC at normal operation to IEC 60502-1. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST1 to IEC 60502-1. APPLICATION For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants and switchgears if mechanical protection is not required, or in applications where the cable is not exposed to mechanical damage. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 70 ºC - Max. admissible temperature of conductor at short circuit 160 ºC for 5 seconds DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 70 ºC mm Ω / km Ω / km 12.1000 7.4100 4.6100 3.0800 1.8300 1.1500 0.7270 0.5240 14.6000 8.8700 5.5400 3.6900 2.1900 1.3900 0.8700 0.6280 2 1.5 2.5 4 6 10 16 25 35 1.5 2.5 4 6 10 16 25 35 9 rm rm rm rm rm rm rm rm rm rm rm rm rm rm rm sm Max. Conductor Resistance 12.1000 7.4100 4.6100 3.0800 1.8300 1.1500 0.7270 0.5240 14.6000 8.8700 5.5400 3.6900 2.1900 1.3900 0.8700 0.6280 Current Rating Laid in ground A Laid in ducts A Approx. overall diameter Approx. overall weight A mm Kg / km 20 28 39 50 66 88 116 143 10.1 10.9 12.9 13.9 15.8 17.9 21.3 23.5 120 145 205 255 390 527 770 965 C208PA10200CBK01IMR 10.6 11.5 13.6 14.7 16.9 19.0 22.7 22.8 145 190 270 340 510 710 1050 1360 C208PA10300CBK04IMR Laid in free air Two Core Cables 24 30 40 50 65 85 110 130 19 25 32 40 55 65 85 105 Three Core Cables 21 27 35 45 60 75 100 120 18 23 30 36 48 60 80 95 18 22 31 39 53 72 94 110 AES Code C210PA10200CBK01IMR C212PA10200CBK01IMR C213PA10200CBK01IMR C314PA10200CBK01IMR C315PA10200CBK01IMR C316PA10200CBK01IMR C317PA10200CBK01IMR C210PA10300CBK04IMR C212PA10300CBK04IMR C213PA10300CBK04IMR C314PA10300CBK04IMR C315PA10300CBK04IMR C316PA10300CBK04IMR C417PA10300CBK04IMR The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / IEC 60502-1 CU / PVC / PVC 0.6 / 1 kV DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 70 ºC mm Ω / km Ω / km 2 Max. Conductor Resistance 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 rm rm rm rm rm rm rm sm sm sm sm sm sm sm sm sm 12.1000 7.4100 4.6100 3.0800 1.8300 1.1500 0.7270 0.5240 0.3870 0.2680 0.1930 0.1530 0.1240 0.0991 0.0754 0.0601 14.6000 8.8700 5.5400 3.6900 2.1900 1.3900 0.8700 0.6280 0.4640 0.3220 0.2320 0.1850 0.1510 0.1210 0.0840 0.0770 35 sm 50 sm 70 sm 95 sm 120 sm 150 sm 185 sm 240 sm 16 rm 25 rm 35 sm 50 sm 70 sm 70 sm 95 sm 120 sm 0.5240 / 1.1500 0.3870 / 0.7270 0.2680 / 0.5240 0.1930 / 0.3870 0.1530 / 0.2680 0.1240 / 0.2680 0.0991 / 0.1930 0.0754 / 0.1530 0.6280 / 1.3900 0.4640 / 0.8700 0.3220 / 0.6280 0.2320 / 0.4640 0.1850 / 0.3220 0.1510 / 0.3220 0.1210 / 0.2320 0.0840 / 0.1850 300 sm 150 sm 0.0601 / 0.1240 Current Rating Laid in ground A Laid in ducts A 18 23 30 36 48 60 80 95 115 145 165 195 220 245 290 320 Approx. overall weight A mm Kg / km 18 22 31 39 53 72 94 110 138 171 209 242 275 314 374 440 11.4 12.4 14.8 16.0 18.5 20.9 25.0 25.1 29.3 32.9 37.8 41.2 45.9 50.7 57.0 63.3 180 230 335 425 650 910 1360 1650 2225 3065 4175 5205 6400 7960 10330 12915 C208PA10400CBK08IMR 1470 2115 2725 3690 4675 5580 7025 9060 C435PA10400CBK08IMR Laid in free air Four Core Cables 21 27 35 45 60 75 100 120 145 175 210 240 270 300 345 390 Approx. overall diameter Four Core Cables with Reduced Neutral 0.0770 / 0.1510 120 145 175 210 240 270 300 345 390 95 115 145 165 195 220 245 290 320 110 138 171 209 242 275 314 374 440 24.0 28.1 31.4 36.1 39.5 43.5 48.2 54.2 60.0 11280 AES Code C210PA10400CBK08IMR C212PA10400CBK08IMR C213PA10400CBK08IMR C314PA10400CBK08IMR C315PA10400CBK08IMR C316PA10400CBK08IMR C417PA10400CBK08IMR C418PA10400CBK08IMR C419PA10400CBK08IMR C445PA10400CBK08IMR C446PA10400CBK08IMF C447PA10400CBK08IMF C448PA10400CBK08IMF C449PA10400CBK08IMS C450PA10400CBK08IMS C436PA10400CBK08IMR C437PA10400CBK08IMR C438PA10400CBK08IMR C439PA10400CBK08IMF C440PA10400CBK08IMF C441PA10400CBK08IMF C442PA10400CBK08IMS C443PA10400CBK08IMS Multi-Core Cables, with Stranded Aluminum Conductors, PVC Insulated and PVC Sheathed CONSTRUCTION Conductor : Stranded circular (rm) or sector shaped (sm) aluminum conductor, as per Class 2 of IEC 60228. Insulation : An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 ºC at normal operation to IEC 60502-1. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST1 to IEC 60502-1. APPLICATION For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants and switchgears if mechanical protection is not required, or in applications where the cable is not exposed to mechanical damage. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 70 ºC - Max. admissible temperature of conductor at short circuit 160 ºC for 5 seconds DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 70 ºC mm2 Ω / km Ω / km 3.0800 1.9100 1.2000 0.8680 3.3000 2.2900 1.4400 1.0430 10 16 25 35 10 16 25 35 11 rm rm rm rm rm rm rm sm Max. Conductor Resistance 3.0800 1.9100 1.2000 0.8680 3.3000 2.2900 1.4400 1.0430 Current Rating Laid in ground A Laid in ducts A 39 46 60 83 Three Core Cables 42 53 70 95 34 42 56 75 Approx. overall weight A mm Kg / km 46 62 81 114 15.8 17.9 21.3 23.5 290 370 435 505 A314PA10200CBK01IMR 37 50 66 88 16.9 19.0 22.7 22.8 320 405 570 700 A314PA10300CBK04IMR Laid in free air Two Core Cables 46 60 77 103 Approx. overall diameter AES Code A315PA10200CBK01IMR A316PA10200CBK01IMR A317PA10200CBK01IMR A315PA10300CBK04IMR A316PA10300CBK04IMR A417PA10300CBK04IMR The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / IEC 60502-1 AL / PVC / PVC 0.6 / 1 kV DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 70 ºC mm Ω / km Ω / km 3.0800 1.9100 1.2000 0.8680 0.6410 0.4430 0.3200 0.2530 0.2060 0.1640 0.1250 0.1000 3.3000 2.2900 1.4400 1.0430 0.7710 0.5330 0.3850 0.3050 0.2490 0.1990 0.1510 0.1230 0.8680 / 1.9100 0.6410 / 1.2000 0.4430 / 0.8680 0.3200 / 0.6410 0.2530 / 0.4430 0.2060 / 0.4430 0.1640 / 0.3200 0.1250 / 0.2530 0.1000 / 0.2060 1.0430 / 2.2900 0.7710 / 1.4400 0.5330 / 1.0430 0.3850 / 0.7710 0.3050 / 0.5330 0.2490 / 0.5330 0.1990 / 0.3850 0.1510 / 0.3050 0.1230 / 0.2490 2 10 16 25 35 50 70 95 120 150 185 240 300 35 sm 50 sm 70 sm 95 sm 120 sm 150 sm 185 sm 240 sm 300 sm rm rm rm sm sm sm sm sm sm sm sm sm 16 rm 25 rm 35 sm 50 sm 70 sm 70 sm 95 sm 120 sm 150 sm Max. Conductor Resistance Current Rating Laid in ground A Laid in ducts A 34 42 56 75 85 110 130 150 170 195 225 260 Approx. overall weight A mm Kg / km 37 50 66 88 105 132 160 187 215 248 292 347 18.5 20.9 25.0 25.1 29.3 32.9 37.8 41.2 45.9 50.7 57.0 63.3 395 510 715 800 1060 1380 1865 2300 2760 3400 4345 5400 A314PA10400CBK08IMR 725 970 1240 1660 2040 2435 3025 3830 4720 A435PA10400CBK08IMR Laid in free air Four Core Cables 42 53 70 95 115 135 165 185 210 235 275 310 Approx. overall diameter Four Core Cables with Reduced Neutral 95 115 135 165 185 210 235 275 310 75 85 110 130 150 170 195 225 260 88 105 132 160 187 215 248 292 347 24.0 28.1 31.4 36.1 39.5 43.5 48.2 54.2 60.0 AES Code A315PA10400CBK08IMR A316PA10400CBK08IMR A417PA10400CBK08IMR A418PA10400CBK08IMR A419PA10400CBK08IMR A445PA10400CBK08IMR A446PA10400CBK08IMF A447PA10400CBK08IMF A448PA10400CBK08IMF A449PA10400CBK08IMS A450PA10400CBK08IMS A436PA10400CBK08IMR A437PA10400CBK08IMR A438PA10400CBK08IMR A439PA10400CBK08IMF A440PA10400CBK08IMF A441PA10400CBK08IMF A442PA10400CBK08IMS A443PA10400CBK08IMS Multi-Core Cables, with Stranded Copper Conductors, PVC Insulated, Steel Tape Armoured and PVC Sheathed CONSTRUCTION Conductor : Plain annealed stranded circular (rm) or sector shaped (sm) copper conductor, as per Class 2 of IEC 60228. Insulation : An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 ºC at normal operation to IEC 60502-1. Bedding : An extruded layer of Polyvinyl chloride (PVC). Armouring : Double layer of galvanized steel tapes. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST1 to IEC 60502-1. APPLICATION For outdoor installations in power stations, industrial plants and switchgears if mechanical protection is required or in applications where mechanical damages are expected to occur. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 70 ºC - Max. admissible temperature of conductor at short circuit 160 ºC for 5 seconds DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 70 ºC mm Ω / km Ω / km 2 13 Max. Conductor Resistance 6 10 16 25 35 rm rm rm rm rm 3.0800 1.8300 1.1500 0.7270 0.5240 3.6900 2.1900 1.3900 0.8700 0.6280 4 6 10 16 25 35 rm rm rm rm rm sm 4.6100 3.0800 1.8300 1.1500 0.7270 0.5240 5.5400 3.6900 2.1900 1.3900 0.8700 0.6280 Current Rating Laid in ground A Laid in ducts A Approx. overall diameter Approx. overall weight A mm Kg / km 50 66 88 116 143 16.9 18.7 20.7 24.1 26.3 460 585 760 1025 1325 C213PA1020GCBK01IMR 16.4 17.5 19.7 21.8 25.5 25.8 440 525 725 950 1340 1560 C212PA1030GCBK04IMR Laid in free air Two Core Cables 50 65 85 110 130 40 55 65 85 105 Three Core Cables 35 45 60 75 100 120 30 36 48 60 80 95 31 39 53 72 94 110 AES Code C314PA1020GCBK01IMR C315PA1020GCBK01IMR C316PA1020GCBK01IMR C317PA1020GCBK01IMR C213PA1030GCBK04IMR C314PA1030GCBK04IMR C315PA1030GCBK04IMR C316PA1030GCBK04IMR C417PA1030GCBK04IMR The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / IEC 60502-1 CU / PVC / STA / PVC 0.6 / 1 kV DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 70 ºC mm Ω / km Ω / km 4.6100 3.0800 1.8300 1.1500 0.7270 0.5240 0.3870 0.2680 0.1930 0.1530 0.1240 0.0991 0.0754 0.0601 5.5400 3.6900 2.1900 1.3900 0.8700 0.6280 0.4640 0.3220 0.2320 0.1850 0.1510 0.1210 0.0840 0.0770 2 4 6 10 16 25 35 50 70 95 120 150 185 240 300 35 sm 50 sm 70 sm 95 sm 120 sm 150 sm 185 sm 240 sm 300 sm rm rm rm rm rm sm sm sm sm sm sm sm sm sm 16 rm 25 rm 35 sm 50 sm 70 sm 70 sm 95 sm 120 sm 150 sm Max. Conductor Resistance 0.5240 / 1.1500 0.3870 / 0.7270 0.2680 / 0.5240 0.1930 / 0.3870 0.1530 / 0.2680 0.1240 / 0.2680 0.0991 / 0.1930 0.0754 / 0.1530 0.0601 / 0.1240 Current Rating Laid in ground A Laid in ducts A 30 36 48 60 80 95 115 145 165 195 220 245 290 320 Approx. overall weight A mm Kg / km 31 39 53 72 94 110 138 171 209 242 275 314 374 440 17.6 18.8 21.3 23.7 27.8 27.9 32.7 37.5 42.4 46.2 50.9 56.1 62.6 68.7 520 630 885 1180 1680 1970 2640 3915 5140 6310 7615 9365 12790 14645 C212PA1040GCBK08IMR 1770 2365 3155 4625 5730 6740 8300 10550 12920 C435PA1040GCBK08IMR Laid in free air Four Core Cables 35 45 60 75 100 120 145 175 210 240 270 300 345 390 Approx. overall diameter Four Core Cables with Reduced Neutral 0.6280 / 1.3900 0.4640 / 0.8700 0.3220 / 0.6280 0.2320 / 0.4640 0.1850 / 0.3220 0.1510 / 0.3220 0.1210 / 0.2320 0.0840 / 0.1850 0.0770 / 0.1510 120 145 175 210 240 270 300 345 390 95 115 145 165 195 220 245 290 320 110 138 171 209 242 275 314 374 440 26.8 30.9 34.6 40.7 44.5 48.5 53.2 59.6 65.4 AES Code C213PA1040GCBK08IMR C314PA1040GCBK08IMR C315PA1040GCBK08IMR C316PA1040GCBK08IMR C417PA1040GCBK08IMR C418PA1040GCBK08IMR C419PA1040GCBK08IMR C445PA1040GCBK08IMF C446PA1040GCBK08IMF C447PA1040GCBK08IMF C448PA1040GCBK08IMS C449PA1040GCBK08IMS C450PA1040GCBK08IMS C436PA1040GCBK08IMR C437PA1040GCBK08IMR C438PA1040GCBK08IMF C439PA1040GCBK08IMF C440PA1040GCBK08IMF C441PA1040GCBK08IMS C442PA1040GCBK08IMS C443PA1040GCBK08IMS Multi-Core Cables, with Stranded Aluminum Conductors, PVC Insulated, Steel Tape Armoured and PVC Sheathed CONSTRUCTION Conductor : Stranded circular (rm) or sector shaped (sm) aluminum conductor, as per Class 2 of IEC 60228. Insulation : An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 ºC at normal operation to IEC 60502-1. Bedding : An extruded layer of Polyvinyl chloride (PVC). Armouring : Double layer of galvanized steel tapes. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST1 to IEC 60502-1. APPLICATION For outdoor installations in power stations, industrial plants and switchgears if mechanical protection is required or in applications where mechanical damages are expected to occur. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 70 ºC - Max. admissible temperature of conductor at short circuit 160 ºC for 5 seconds DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 70 ºC mm Ω / km Ω / km 3.0800 1.9100 1.2000 0.8680 3.3000 2.2900 1.4400 1.0430 2 10 16 25 35 10 16 25 35 15 rm rm rm rm rm rm rm sm Max. Conductor Resistance 3.0800 1.9100 1.2000 0.8680 3.3000 2.2900 1.4400 1.0430 Current Rating Laid in ground A Laid in ducts A Approx. overall diameter Approx. overall weight A mm Kg / km 46 62 81 115 16.7 20.7 24.1 26.3 455 540 730 880 A314PA1020GCBK01IMR 19.7 21.8 25.5 25.8 535 625 855 1250 A314PA1030GCBK04IMR Laid in free air Two Core Cables 46 60 77 103 39 46 60 83 Three Core Cables 42 53 70 95 34 42 56 75 37 50 66 88 AES Code A315PA1020GCBK01IMR A316PA1020GCBK01IMR A317PA1020GCBK01IMR A315PA1030GCBK04IMR A316PA1030GCBK04IMR A417PA1030GCBK04IMR The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / IEC 60502-1 AL / PVC / STA / PVC 0.6 / 1 kV DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 70 ºC mm Ω / km Ω / km 3.0800 1.9100 1.2000 0.8680 0.6410 0.4430 0.3200 0.2530 0.2060 0.1640 0.1250 0.1000 3.3000 2.2900 1.4400 1.0430 0.7710 0.5330 0.3850 0.3050 0.2490 0.1990 0.1510 0.1230 0.8680 / 1.9100 0.6410 / 1.2000 0.4430 / 0.8680 0.3200 / 0.6410 0.2530 / 0.4430 0.2060 / 0.4430 0.1640 / 0.3200 0.1250 / 0.2530 0.1000 / 0.2060 1.0430 / 2.2900 0.7710 / 1.4400 0.5330 / 1.0430 0.3850 / 0.7710 0.3050 / 0.5330 0.2490 / 0.5330 0.1990 / 0.3850 0.1510 / 0.3050 0.1230 / 0.2490 2 10 16 25 35 50 70 95 120 150 185 240 300 35 sm 50 sm 70 sm 95 sm 120 sm 150 sm 185 sm 240 sm 300 sm rm rm rm sm sm sm sm sm sm sm sm sm 16 rm 25 rm 35 sm 50 sm 70 sm 70 sm 95 sm 120 sm 150 sm Max. Conductor Resistance Current Rating Laid in ground A Laid in ducts A 34 42 56 75 85 110 130 150 170 195 225 260 Approx. overall weight A mm Kg / km 37 50 66 88 105 132 160 187 215 248 292 347 21.3 23.7 27.8 27.9 32.7 37.5 42.4 46.2 50.9 56.1 62.6 68.7 630 775 1035 1115 1475 2225 2830 3360 3975 4815 5925 7125 A314PA1040GCBK08IMR 1030 1330 1675 2585 3100 3590 4300 5325 6365 A435PA1040GCBK08IMR Laid in free air Four Core Cables 42 53 70 95 115 135 165 185 210 235 275 310 Approx. overall diameter Four Core Cables with Reduced Neutral 95 115 135 165 185 210 235 275 310 75 85 110 130 150 170 195 225 260 88 105 132 160 187 215 248 292 347 26.8 30.9 34.6 40.7 44.5 48.5 53.2 59.6 65.4 AES Code A315PA1040GCBK08IMR A316PA1040GCBK08IMR A417PA1040GCBK08IMR A418PA1040GCBK08IMR A419PA1040GCBK08IMR A445PA1040GCBK08IMR A446PA1040GCBK08IMF A447PA1040GCBK08IMF A448PA1040GCBK08IMF A449PA1040GCBK08IMS A450PA1040GCBK08IMS A436PA1040GCBK08IMR A437PA1040GCBK08IMR A438PA1040GCBK08IMR A439PA1040GCBK08IMF A440PA1040GCBK08IMF A441PA1040GCBK08IMF A442PA1040GCBK08IMS A443PA1040GCBK08IMS Multi-Core Cables, with Stranded Copper Conductors, PVC Insulated, Steel Wire Armoured and PVC Sheathed CONSTRUCTION Conductor : Plain annealed stranded circular (rm) or sector shaped (sm) copper conductor, as per Class 2 of IEC 60228. Insulation : An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 ºC at normal operation to IEC 60502-1. Bedding : An extruded layer of Polyvinyl chloride (PVC). Armouring : Single layer of round galvanized steel wires. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST1 to IEC 60502-1. APPLICATION For outdoor installations in power stations, industrial plants and switchgears if mechanical protection is required or in applications where mechanical damages are expected to occur. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 70 ºC - Max. admissible temperature of conductor at short circuit 160 ºC for 5 seconds DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 70 ºC mm Ω / km Ω / km 2 17 Max. Conductor Resistance 4 6 10 16 25 35 rm rm rm rm rm rm 4.6100 3.0800 1.8300 1.1500 0.7270 0.5240 5.5400 3.6900 2.1900 1.3900 0.8700 0.6280 4 6 10 16 25 35 rm rm rm rm rm sm 4.6100 3.0800 1.8300 1.1500 0.7270 0.5240 5.5400 3.6900 2.1900 1.3900 0.8700 0.6280 Current Rating Laid in ground A Laid in ducts A Approx. overall diameter Approx. overall weight A mm Kg / km 39 50 66 88 116 143 17.8 18.8 21.6 22.4 26.9 29.5 645 735 800 1085 1760 2120 C212PA1020WCBK01IMR 18.5 19.6 21.8 23.9 28.6 28.8 730 835 1080 1350 1985 2420 C212PA1030WCBK04IMR Laid in free air Two Core Cables 40 50 65 85 110 130 32 40 55 65 85 105 Three Core Cables 35 45 60 75 100 120 30 36 48 60 80 100 31 39 53 72 94 110 AES Code C213PA1020WCBK01IMR C314PA1020WCBK01IMR C315PA1020WCBK01IMR C316PA1020WCBK01IMR C317PA1020WCBK01IMR C213PA1030WCBK04IMR C314PA1030WCBK04IMR C315PA1030WCBK04IMR C316PA1030WCBK04IMR C417PA1030WCBK04IMR The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / IEC 60502-1 CU / PVC / SWA / PVC 0.6 / 1 kV DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 70 ºC mm Ω / km Ω / km 4.6100 3.0800 1.8300 1.1500 0.7270 0.5240 0.3870 0.2680 0.1930 0.1530 0.1240 0.0991 0.0754 0.0601 5.5400 3.6900 2.1900 1.3900 0.8700 0.6280 0.4640 0.3220 0.2320 0.1850 0.1510 0.1210 0.0840 0.0770 2 4 6 10 16 25 35 50 70 95 120 150 185 240 300 35 sm 50 sm 70 sm 95 sm 120 sm 150 sm 185 sm 240 sm 300 sm rm rm rm rm rm sm sm sm sm sm sm sm sm sm 16 rm 25 rm 35 sm 50 sm 70 sm 70 sm 95 sm 120 sm 150 sm Max. Conductor Resistance 0.5240 / 1.1500 0.3870 / 0.7270 0.2680 / 0.5240 0.1930 / 0.3870 0.1530 / 0.2680 0.1240 / 0.2680 0.0991 / 0.1930 0.0754 / 0.1530 0.0601 / 0.1240 Current Rating Laid in ground A Laid in ducts A 29 37 50 68 89 95 115 145 165 195 220 245 290 320 Approx. overall weight A mm Kg / km 29 37 50 68 89 116 143 176 215 248 281 319 380 446 19.7 20.9 23.4 26.5 30.6 30.9 37.1 40.7 46.6 50.6 55.1 60.5 66.8 72.9 840 965 1275 1780 2380 2690 3870 4900 6665 7990 9445 11425 14205 17870 C212PA1040WCBK08IMR 2460 3550 4480 5475 7385 8505 10260 12755 15330 C435PA1040WCBK08IMR Laid in free air Four Core Cables 37 47 63 79 105 120 145 175 210 240 270 300 345 390 Approx. overall diameter Four Core Cables with Reduced Neutral 0.6280 / 1.3900 0.4640 / 0.8700 0.3220 / 0.6280 0.2320 / 0.4640 0.1850 / 0.3220 0.1510 / 0.3220 0.1210 / 0.2320 0.0840 / 0.1850 0.0770 / 0.1510 120 145 175 210 240 270 300 345 390 95 115 145 165 195 220 245 290 320 116 143 176 215 248 281 319 380 446 29.8 35.5 39.2 42.6 48.9 52.7 57.6 64.0 69.8 AES Code C213PA1040WCBK08IMR C314PA1040WCBK08IMR C315PA1040WCBK08IMR C316PA1040WCBK08IMR C417PA1040WCBK08IMR C418PA1040WCBK08IMR C419PA1040WCBK08IMR C445PA1040WCBK08IMF C446PA1040WCBK08IMF C447PA1040WCBK08IMF C448PA1040WCBK08IMS C449PA1040WCBK08IMS C450PA1040WCBK08IMS C436PA1040WCBK08IMR C437PA1040WCBK08IMR C438PA1040WCBK08IMF C439PA1040WCBK08IMF C440PA1040WCBK08IMF C441PA1040WCBK08IMS C442PA1040WCBK08IMS C443PA1040WCBK08IMS Multi-Core Cables, with Stranded Aluminum Conductors, PVC Insulated, Steel Wire Armoured and PVC Sheathed CONSTRUCTION Conductor : Stranded circular (rm) or sector shaped (sm) aluminum conductor, as per Class 2 of IEC 60228. Insulation : An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 ºC at normal operation to IEC 60502-1. Bedding : An extruded layer of Polyvinyl chloride (PVC). Armouring : Single layer of round galvanized steel wires. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST1 to IEC 60502-1. APPLICATION For outdoor installations in power stations, industrial plants and switchgears if mechanical protection is required or in applications where mechanical damages are expected to occur. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 70 ºC - Max. admissible temperature of conductor at short circuit 160 ºC for 5 seconds DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 70 ºC mm Ω / km Ω / km 3.0800 1.9100 1.2000 0.8680 3.3000 2.2900 1.4400 1.0430 2 10 16 25 35 10 16 25 35 19 rm rm rm rm rm rm rm sm Max. Conductor Resistance 3.0800 1.9100 1.2000 0.8680 3.3000 2.2900 1.4400 1.0430 Current Rating Laid in ground A Laid in ducts A Approx. overall diameter Approx. overall weight A mm Kg / km 46 62 81 115 21.6 22.4 26.9 29.5 680 825 1450 2250 A314PA1020WCBK01IMR 21.8 23.9 28.6 28.8 915 1525 1875 2330 A314PA1030WCBK04IMR Laid in free air Two Core Cables 46 60 77 103 39 46 60 83 Three Core Cables 42 53 70 95 34 42 56 75 37 50 66 88 AES Code A315PA1020WCBK01IMR A316PA1020WCBK01IMR A317PA1020WCBK01IMR A315PA1030WCBK04IMR A316PA1030WCBK04IMR A417PA1030WCBK04IMR The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / IEC 60502-1 AL / PVC / SWA / PVC 0.6 / 1 kV DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 70 ºC mm Ω / km 2 Max. Conductor Resistance Current Rating Ω / km Laid in ground A Laid in ducts A Laid in free air A 42 53 70 95 115 135 165 185 210 235 275 310 34 42 56 75 85 110 130 150 170 195 225 260 37 50 66 88 105 138 165 193 220 253 297 352 10 16 25 35 50 70 95 120 150 185 240 300 rm rm rm sm sm sm sm sm sm sm sm sm 3.0800 1.9100 1.2000 0.8680 0.6410 0.4430 0.3200 0.2530 0.2060 0.1640 0.1250 0.1000 3.3000 2.2900 1.4400 1.0430 0.7710 0.5330 0.3850 0.3050 0.2490 0.1990 0.1510 0.1230 35 sm 50 sm 70 sm 95 sm 120 sm 150 sm 185 sm 240 sm 300 sm 16 rm 25 rm 35 sm 50 sm 70 sm 70 sm 95 sm 120 sm 150 sm 0.8680 / 1.9100 0.6410 / 1.2000 0.4430 / 0.8680 0.3200 / 0.6410 0.2530 / 0.4430 0.2060 / 0.4430 0.1640 / 0.3200 0.1250 / 0.2530 0.1000 / 0.2060 1.0430 / 2.2900 0.7710 / 1.4400 0.5330 / 1.0430 0.3850 / 0.7710 0.3050 / 0.5330 0.2490 / 0.5330 0.1990 / 0.3850 0.1510 / 0.3050 0.1230 / 0.2490 Four Core Cables Approx. overall diameter Approx. overall weight mm Kg / km 23.4 26.5 30.6 30.9 37.1 40.7 46.6 50.6 55.1 60.5 66.8 72.9 1420 1720 2110 1780 3040 3750 4730 5570 6430 7790 9180 10590 A314PA1040WCBK08IMR 1550 2300 2820 3410 4370 5080 5950 7230 8540 A435PA1040WCBK08IMR Four Core Cables with Reduced Neutral 95 115 135 165 185 210 235 275 310 75 85 110 130 150 170 195 225 260 94 110 138 165 193 220 253 297 352 29.8 35.5 39.2 42.6 48.9 52.7 57.6 64.0 69.8 AES Code A315PA1040WCBK08IMR A316PA1040WCBK08IMR A417PA1040WCBK08IMR A418PA1040WCBK08IMR A419PA1040WCBK08IMR A445PA1040WCBK08IMR A446PA1040WCBK08IMF A447PA1040WCBK08IMF A448PA1040WCBK08IMF A449PA1040WCBK08IMS A450PA1040WCBK08IMS A436PA1040WCBK08IMR A437PA1040WCBK08IMR A438PA1040WCBK08IMR A439PA1040WCBK08IMF A440PA1040WCBK08IMF A441PA1040WCBK08IMF A442PA1040WCBK08IMS A443PA1040WCBK08IMS Single-Core Cables, with Stranded Circular Copper Conductors, XLPE Insulated and PVC Sheathed CONSTRUCTION Conductor : Plain annealed stranded circular copper conductor, as per Class 2 of IEC 60228. Insulation : An extruded layer of Cross linked polyethylene (XLPE) insulation, rated 90 ºC at normal operation to IEC 60502-1. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST2 to IEC 60502-1. APPLICATION For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants and switchgears if mechanical protection is not required, or in applications where the cable is not exposed to mechanical damage. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 90 ºC - Max. admissible temperature of conductor at short circuit 250 ºC for 5 seconds 21 The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / IEC 60502-1 CU / XLPE / PVC Nominal cross sectional area mm2 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 1000 0.6 / 1 kV DIMENSIONS AND WEIGHTS ELECTRICAL DATA Current Rating Laid in ground Laid in free air Max. Conductor Resistance DC at 20 ºC Ω / km 4.6100 3.0800 1.8300 1.1500 0.7270 0.5240 0.3870 0.2680 0.1930 0.1530 0.1240 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283 0.0221 0.0176 AC at 90 ºC Ω / km 5.8800 3.9300 2.3300 1.4700 0.9270 0.6690 0.4940 0.3430 0.2480 0.1970 0.1600 0.1290 0.0990 0.0810 0.0638 0.0517 0.0425 0.0292 0.0234 A 55 68 98 116 150 179 210 263 310 357 394 452 520 588 672 761 872 957 1082 A 51 65 86 111 142 172 200 247 294 336 373 425 488 546 620 693 777 861 935 A 40 53 68 87 110 137 163 200 242 273 310 352 404 457 515 572 651 735 798 A 53 65 84 116 143 179 221 278 347 404 457 530 651 824 893 1008 1155 1313 1449 A 47 59 79 110 137 173 210 268 336 394 446 520 641 756 872 987 1134 1292 1428 A 40 53 68 95 121 152 184 236 289 341 389 441 536 620 714 814 956 1092 1208 Approx. overall diameter Approx. overall weight mm Kg / km 6.8 7.3 8.3 9.3 11.0 12.1 13.8 15.7 17.7 19.6 21.8 23.9 27.1 29.7 33.9 37.4 41.9 46.8 51.5 80 102 150 210 315 410 555 760 1015 1280 1570 1920 2530 3105 4135 5110 6455 8260 10075 AES Code C212XA10100MBK51IMR C213XA10100MBK51IMR C314XA10100MBK51IMR C315XA10100MBK51IMR C316XA10100MBK51IMR C317XA10100MBK51IMR C318XA10100MBK51IMR C319XA10100MBK51IMR C345XA10100MBK51IMR C346XA10100MBK51IMR C347XA10100MBK51IMR C348XA10100MBK51IMR C349XA10100MBK51IMR C350XA10100MBK51IMR C351XA10100MBK51IMF C352XA10100MBK51IMF C353XA10100MBK51IMF C354XA10100MBK51IMF C355XA10100MBK51IMF Single-Core Cables, with Stranded Circular Aluminum Conductors, XLPE Insulated and PVC Sheathed CONSTRUCTION Conductor : Stranded circular aluminum conductor, as per Class 2 of IEC 60228. Insulation : An extruded layer of Cross linked polyethylene (XLPE) insulation, rated 90 ºC at normal operation to IEC 60502-1. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST2 to IEC 60502-1. APPLICATION For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants and switchgears if mechanical protection is not required, or in applications where the cable is not exposed to mechanical damage. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 90 ºC - Max. admissible temperature of conductor at short circuit 250 ºC for 5 seconds 23 The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / IEC 60502-1 AL / XLPE / PVC Nominal cross sectional area mm2 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 1000 0.6 / 1 kV DIMENSIONS AND WEIGHTS ELECTRICAL DATA Current Rating Laid in ground Laid in free air Max. Conductor Resistance DC at 20 ºC Ω / km 1.9100 1.2000 0.8680 0.6410 0.4430 0.3200 0.2530 0.2060 0.1640 0.1250 0.1000 0.0778 0.0605 0.0469 0.0367 0.0291 AC at 90 ºC Ω / km 2.4500 1.5400 1.1130 0.8220 0.5690 0.4110 0.3250 0.2650 0.2120 0.1630 0.1310 0.1000 0.0870 0.0620 0.0560 0.0470 A 89 113 137 163 200 236 278 310 352 410 467 541 609 698 788 872 A 87 110 131 155 189 226 263 294 336 389 436 504 567 646 704 767 A 66 84 105 121 152 179 215 236 267 315 357 410 467 536 599 651 A 89 116 142 173 221 284 326 373 436 515 578 693 809 945 1071 1176 A 84 110 137 168 215 273 315 362 420 499 567 677 788 924 1050 1155 A 63 95 121 147 179 215 242 299 336 399 462 541 630 746 851 966 Approx. overall diameter Approx. overall weight mm Kg / km 9.3 11.0 12.1 13.8 15.7 17.7 19.6 21.8 23.9 27.1 29.7 33.9 37.4 41.9 46.8 51.5 115 165 205 260 340 450 550 670 830 1050 1300 1610 2000 2520 3150 3870 AES Code A315XA10100MBK51IMR A316XA10100MBK51IMR A317XA10100MBK51IMR A318XA10100MBK51IMR A319XA10100MBK51IMR A345XA10100MBK51IMR A346XA10100MBK51IMR A347XA10100MBK51IMR A348XA10100MBK51IMR A349XA10100MBK51IMR A350XA10100MBK51IMR A351XA10100MBK51IMR A352XA10100MBK51IMF A353XA10100MBK51IMF A354XA10100MBK51IMF A355XA10100MBK51IMF POWER CABLES / IEC 60502-1 CU / XLPE / PVC 0.6 / 1 kV Multi-Core Cables, with Stranded Aluminum Conductors, XLPE Insulated and PVC Sheathed CONSTRUCTION Conductor : Stranded circular (rm) or sector shaped (sm) aluminum conductor, as per Class 2 of IEC 60228. Insulation : An extruded layer of Cross linked polyethylene (XLPE) insulation, rated 90 ºC at normal operation to IEC 60502-1. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST2 to IEC 60502-1. APPLICATION For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants and switchgears if mechanical protection is not required, or in applications where the cable is not exposed to mechanical damage. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 90 ºC - Max. admissible temperature of conductor at short circuit 250 ºC for 5 seconds DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 90 ºC mm Ω / km Ω / km 2 27 Max. Conductor Resistance 10 16 25 35 rm rm rm rm 3.0800 1.9100 1.2000 0.8680 3.9500 2.4500 1.5400 1.1130 10 16 25 35 rm rm rm sm 3.0800 1.9100 1.2000 0.8680 3.9500 2.4500 1.5400 1.1130 Current Rating Laid in ground A Laid in ducts A Approx. overall diameter Approx. overall weight A mm Kg / km 55 73 97 120 14.7 16.7 20.1 22.3 335 450 640 780 A314XA10200MBK01IMR 15.6 17.7 21.4 21.5 375 605 835 1050 A314XA10300MBK04IMR Laid in free air Two Core Cables 57 74 97 128 48 58 75 106 Three Core Cables 52 68 90 120 42 52 71 95 48 62 84 105 AES Code A315XA10200MBK01IMR A316XA10200MBK01IMR A317XA10200MBK01IMR A315XA10300MBK04IMR A316XA10300MBK04IMR A417XA10300MBK04IMR The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / IEC 60502-1 AL / XLPE / PVC 0.6 / 1 kV DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 90 ºC mm Ω / km Ω / km 3.0800 1.9100 1.2000 0.8680 0.6410 0.4430 0.3200 0.2530 0.2060 0.1640 0.1250 0.1000 3.9500 2.4500 1.5400 1.1130 0.8220 0.5690 0.4110 0.3250 0.2650 0.2120 0.1630 0.1310 0.8680 / 1.9100 0.6410 / 1.2000 0.4430 / 0.8680 0.3200 / 0.6410 0.2530 / 0.4430 0.2060 / 0.4430 0.1640 / 0.3200 0.1250 / 0.2530 0.1000 / 0.2060 1.1130 / 2.4500 0.8220 / 1.5400 0.5690 / 1.1130 0.4110 / 0.8220 0.3250 / 0.5690 0.2650 / 0.5690 2 10 16 25 35 50 70 95 120 150 185 240 300 35 sm 50 sm 70 sm 95 sm 120 sm 150 sm 185 sm 240 sm 300 sm rm rm rm sm sm sm sm sm sm sm sm sm 16 rm 25 rm 35 sm 50 sm 70 sm 70 sm 95 sm 120 sm 150 sm Max. Conductor Resistance Current Rating Laid in ground A Laid in ducts A 42 52 71 95 110 140 165 190 215 240 280 315 Approx. overall weight A mm Kg / km 48 62 84 110 136 168 205 236 278 315 378 446 17.0 19.4 23.5 23.6 27.1 31.4 35.1 39.2 43.7 48.7 54.5 60.1 450 700 925 800 950 1260 1650 2060 2520 3140 4020 4930 A314PA10400MBK08IMR 610 925 1255 1630 2030 2515 3095 3900 4795 A435XA10400MBK08IMR Laid in free air Four Core Cables 52 68 90 120 145 175 210 235 265 290 340 390 Approx. overall diameter Four Core Cables with Reduced Neutral 0.2120 / 0.4110 0.1630 / 0.3250 0.1310 / 0.2650 121 145 178 214 243 272 309 359 406 96 116 142 171 195 220 250 292 331 110 136 171 211 246 282 326 388 449 22.5 25.9 29.7 33.6 37.5 41.3 46.2 51.5 56.8 AES Code A315PA10400MBK08IMR A316PA10400MBK08IMR A417PA10400MBK08IMR A418PA10400MBK08IMR A419PA10400MBK08IMR A445XA10400MBK08IMR A446XA10400MBK08IMF A447XA10400MBK08IMF A448XA10400MBK08IMF A449XA10400MBK08IMS A450XA10400MBK08IMS A436XA10400MBK08IMR A437XA10400MBK08IMR A438XA10400MBK08IMR A439XA10400MBK08IMF A440XA10400MBK08IMF A441XA10400MBK08IMF A442XA10400MBK08IMS A443XA10400MBK08IMS Multi-Core Cables, with Stranded Copper Conductors, XLPE Insulated, Steel Tape Armoured and PVC Sheathed CONSTRUCTION Conductor : Plain annealed stranded circular (rm) or sector shaped (sm) copper conductor, as per Class 2 of IEC 60228. Insulation : An extruded layer of Cross linked polyethylene (XLPE) insulation, rated 90 ºC at normal operation to IEC 60502-1. Bedding : An extruded layer of Polyvinyl chloride (PVC). Armouring : Double layer of galvanized steel tapes. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST2 to IEC 60502-1. APPLICATION For outdoor installations in power stations, industrial plants and switchgears if mechanical protection is required or in applications where mechanical damages are expected to occur. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 90 ºC - Max. admissible temperature of conductor at short circuit 250 ºC for 5 seconds DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 90 ºC mm2 Ω / km Ω / km 3.0800 1.8300 1.1500 0.7270 0.5240 3.9300 2.3300 1.4700 0.9270 0.6690 6 10 16 25 35 6 10 16 25 35 29 rm rm rm rm rm rm rm rm rm sm Max. Conductor Resistance Current Rating Laid in ground A Laid in ducts A Approx. overall diameter Approx. overall weight A mm Kg / km 59 78 103 137 164 15.5 17.5 19.5 22.1 23.8 405 530 685 930 1245 C213XA1020GMBK01IMR 16.2 18.4 20.5 24.2 22.8 465 650 870 1235 1370 C213XA1030GMBK04IMR Laid in free air Two Core Cables 62 81 105 138 164 51 68 82 106 132 AES Code C314XA1020GMBK01IMR C315XA1020GMBK01IMR C316XA1020GMBK01IMR C317XA1020GMBK01IMR Three Core Cables 3.0800 1.8300 1.1500 0.7270 0.5240 3.9300 2.3300 1.4700 0.9270 0.6690 56 74 96 127 153 44 59 74 100 119 49 67 88 120 143 C314XA1030GMBK04IMR C315XA1030GMBK04IMR C316XA1030GMBK04IMR C417XA1030GMBK04IMR The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / IEC 60502-1 CU / XLPE / STA / PVC 0.6 / 1 kV DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 90 ºC mm Ω / km Ω / km 3.0800 1.8300 1.1500 0.7270 0.5240 0.3870 0.2680 0.1930 0.1530 0.1240 0.0991 0.0754 0.0601 3.9300 2.3300 1.4700 0.9270 0.6690 0.4940 0.3430 0.2480 0.1970 0.1600 0.1290 0.0990 0.0810 2 6 10 16 25 35 50 70 95 120 150 185 240 300 35 sm 50 sm 70 sm 95 sm 120 sm 150 sm 185 sm 240 sm 300 sm rm rm rm rm sm sm sm sm sm sm sm sm sm 16 rm 25 rm 35 sm 50 sm 70 sm 70 sm 95 sm 120 sm 150 sm Max. Conductor Resistance 0.5240 / 1.1500 0.3870 / 0.7270 0.2680 / 0.5240 0.1930 / 0.3870 0.1530 / 0.2680 0.1240 / 0.2680 0.0991 / 0.1930 0.0754 / 0.1530 0.0601 / 0.1240 Current Rating Laid in ground A Laid in ducts A 44 59 74 100 119 145 180 210 245 275 310 365 405 Approx. overall weight A mm Kg / km 49 67 88 120 143 178 215 268 310 352 404 483 562 17.4 19.8 22.2 26.3 26.4 30.1 34.6 39.7 43.8 48.7 53.7 60.0 65.5 555 795 1075 1540 1830 2415 3335 4815 5910 7195 8830 11285 13835 C213XA1040GMBK08IMR 1640 2160 2960 4280 5365 6355 7865 10000 12205 C435XA1040GMBK08IMR Laid in free air Four Core Cables 56 74 96 127 153 185 220 265 305 335 375 435 490 Approx. overall diameter Four Core Cables with Reduced Neutral 0.6690 / 1.4700 0.4940 / 0.9270 0.3430 / 0.6690 0.2480 / 0.4940 0.1970 / 0.3430 0.1600 / 0.3430 0.1290 / 0.2480 0.0990 / 0.1970 0.0810 / 0.1600 153 185 220 265 305 335 375 435 490 119 145 180 210 245 275 310 365 405 143 178 215 268 310 352 404 483 562 25.3 28.7 33.1 38.0 42.1 46.3 51.2 57.1 62.2 AES Code C314XA1040GMBK08IMR C315XA1040GMBK08IMR C316XA1040GMBK08IMR C417XA1040GMBK08IMR C418XA1040GMBK08IMR C419XA1040GMBK08IMR C445XA1040GMBK08IMF C446XA1040GMBK08IMF C447XA1040GMBK08IMF C448XA1040GMBK08IMS C449XA1040GMBK08IMS C450XA1040GMBK08IMS C436XA1040GMBK08IMR C437XA1040GMBK08IMR C438XA1040GMBK08IMF C439XA1040GMBK08IMF C440XA1040GMBK08IMF C441XA1040GMBK08IMS C442XA1040GMBK08IMS C443XA1040GMBK08IMS Multi-Core Cables, with Stranded Aluminum Conductors, XLPE Insulated, Steel Tape Armoured and PVC Sheathed CONSTRUCTION Conductor : Stranded circular (rm) or sector shaped (sm) aluminum conductor, as per Class 2 of IEC 60228. Insulation : An extruded layer of Cross linked polyethylene (XLPE) insulation, rated 90 ºC at normal operation to IEC 60502-1. Bedding : An extruded layer of Polyvinyl chloride (PVC). Armouring : Double layer of galvanized steel tapes. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST2 to IEC 60502-1. APPLICATION For outdoor installations in power stations, industrial plants and switchgears if mechanical protection is required or in applications where mechanical damages are expected to occur. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 90 ºC - Max. admissible temperature of conductor at short circuit 250 ºC for 5 seconds DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 90 ºC mm2 Ω / km Ω / km 3.0800 1.9100 1.2000 0.8680 3.9500 2.4500 1.5400 1.1130 10 16 25 35 10 16 25 35 31 rm rm rm rm rm rm rm sm Max. Conductor Resistance 3.0800 1.9100 1.2000 0.8680 3.9500 2.4500 1.5400 1.1130 Current Rating Laid in ground A Laid in ducts A Approx. overall diameter Approx. overall weight A mm Kg / km 55 72 96 126 17.5 19.5 22.1 25.1 480 595 810 950 A314XA1020GMBK01IMR 18.4 20.5 24.2 24.5 555 685 925 1110 A314XA1030GMBK04IMR Laid in free air Two Core Cables 56 73 96 129 47 57 74 105 Three Core Cables 52 67 89 120 41 52 70 95 47 62 84 110 AES Code A315XA1020GMBK01IMR A316XA1020GMBK01IMR A317XA1020GMBK01IMR A315XA1030GMBK04IMR A316XA1030GMBK04IMR A417XA1030GMBK04IMR The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / IEC 60502-1 AL / XLPE / STA / PVC 0.6 / 1 kV DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 90 ºC mm Ω / km Ω / km 3.0800 1.9100 1.2000 0.8680 0.6410 0.4430 0.3200 0.2530 0.2060 0.1640 0.1250 0.1000 3.9500 2.4500 1.5400 1.1130 0.8220 0.5690 0.4110 0.3250 0.2650 0.2120 0.1630 0.1310 0.8680 / 1.9100 0.6410 / 1.2000 0.4430 / 0.8680 0.3200 / 0.6410 0.2530 / 0.4430 0.2060 / 0.4430 0.1640 / 0.3200 0.1250 / 0.2530 0.1000 / 0.2060 1.1130 / 2.4500 0.8220 / 1.5400 0.5690 / 1.1130 0.4110 / 0.8220 0.3250 / 0.5690 0.2650 / 0.5690 0.2120 / 0.4110 0.1630 / 0.3250 0.1310 / 0.2650 2 10 16 25 35 50 70 95 120 150 185 240 300 35 sm 50 sm 70 sm 95 sm 120 sm 150 sm 185 sm 240 sm 300 sm rm rm rm sm sm sm sm sm sm sm sm sm 16 rm 25 rm 35 sm 50 sm 70 sm 70 sm 95 sm 120 sm 150 sm Max. Conductor Resistance Current Rating Laid in ground A Laid in ducts A 41 52 70 95 110 140 165 190 215 240 280 315 Approx. overall weight A mm Kg / km 47 62 84 110 136 168 205 236 278 315 378 446 19.8 22.2 26.3 26.4 30.1 34.6 39.7 43.8 48.7 53.7 60.0 65.5 635 795 1090 970 1490 1750 2540 3020 3670 4380 4430 6510 A314XA1040GMBK08IMR 895 1200 1550 1970 2710 3290 3980 4910 5920 A435XA1040GMBK08IMR Laid in free air Four Core Cables 52 67 89 120 145 175 210 235 265 290 340 390 Approx. overall diameter Four Core Cables with Reduced Neutral 120 145 175 210 235 265 290 340 390 95 110 140 165 190 215 240 280 315 110 136 168 205 236 278 315 378 446 25.3 28.7 33.1 38.0 42.1 46.3 51.2 57.1 62.2 AES Code A315XA1040GMBK08IMR A316XA1040GMBK08IMR A417XA1040GMBK08IMR A418XA1040GMBK08IMR A419XA1040GMBK08IMR A445XA1040GMBK08IMR A446XA1040GMBK08IMF A447XA1040GMBK08IMF A448XA1040GMBK08IMF A449XA1040GMBK08IMS A450XA1040GMBK08IMS A436XA1040GMBK08IMR A437XA1040GMBK08IMR A438XA1040GMBK08IMR A439XA1040GMBK08IMF A440XA1040GMBK08IMF A441XA1040GMBK08IMF A442XA1040GMBK08IMS A443XA1040GMBK08IMS Multi-Core Cables, with Stranded Copper Conductors, XLPE Insulated, Steel Wire Armoured and PVC Sheathed CONSTRUCTION Conductor : Plain annealed stranded circular (rm) or sector shaped (sm) copper conductor, as per Class 2 of IEC 60228. Insulation : An extruded layer of Cross linked polyethylene (XLPE) insulation, rated 90 ºC at normal operation to IEC 60502-1. Bedding : An extruded layer of Polyvinyl chloride (PVC). Armouring : Single layer of round galvanized steel wires. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST2 to IEC 60502-1. APPLICATION For outdoor installations in power stations, industrial plants and switchgears if mechanical protection is required or in applications where mechanical damages are expected to occur. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 90 ºC - Max. admissible temperature of conductor at short circuit 250 ºC for 5 seconds DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 90 ºC mm2 Ω / km Ω / km 4.6100 3.0800 1.8300 1.1500 0.7270 0.5240 5.8800 3.9300 2.3300 1.4700 0.9270 0.6690 4 6 10 16 25 35 4 6 10 16 25 35 33 rm rm rm rm rm rm rm rm rm rm rm sm Max. Conductor Resistance 4.6100 3.0800 1.8300 1.1500 0.7270 0.5240 5.8800 3.9300 2.3300 1.4700 0.9270 0.6690 Current Rating Laid in ground A Laid in ducts A Approx. overall diameter Approx. overall weight A mm Kg / km 47 61 80 106 140 168 16.6 17.6 19.6 21.6 24.2 27.5 580 660 835 1020 1335 1755 C212XA1020WMBK01IMR 17.2 18.3 20.5 22.6 27.0 27.3 650 755 965 1240 1850 2220 C212XA1030WMBK04IMR Laid in free air Two Core Cables 51 64 83 107 140 168 41 53 70 84 108 135 Three Core Cables 46 58 76 98 130 158 37 46 61 76 103 122 42 51 69 90 120 147 AES Code C213XA1020WMBK01IMR C314XA1020WMBK01IMR C315XA1020WMBK01IMR C316XA1020WMBK01IMR C317XA1020WMBK01IMR C213XA1030WMBK04IMR C314XA1030WMBK04IMR C315XA1030WMBK04IMR C316XA1030WMBK04IMR C417XA1030WMBK04IMR The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / IEC 60502-1 CU / XLPE / SWA / PVC 0.6 / 1 kV DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 90 ºC mm Ω / km Ω / km 4.6100 3.0800 1.8300 1.1500 0.7270 0.5240 0.3870 0.2680 0.1930 0.1530 0.1240 0.0991 0.0754 0.0601 5.8800 3.9300 2.3300 1.4700 0.9270 0.6690 0.4940 0.3430 0.2480 0.1970 0.1600 0.1290 0.0990 0.0810 2 4 6 10 16 25 35 50 70 95 120 150 185 240 300 35 sm 50 sm 70 sm 95 sm 120 sm 150 sm 185 sm 240 sm 300 sm rm rm rm rm rm sm sm sm sm sm sm sm sm sm 16 rm 25 rm 35 sm 50 sm 70 sm 70 sm 95 sm 120 sm 150 sm Max. Conductor Resistance 0.5240 / 1.1500 0.3870 / 0.7270 0.2680 / 0.5240 0.1930 / 0.3870 0.1530 / 0.2680 0.1240 / 0.2680 0.0991 / 0.1930 0.0754 / 0.1530 0.0601 / 0.1240 Current Rating Laid in ground A Laid in ducts A 37 46 61 76 103 122 145 180 210 245 275 310 365 405 Approx. overall weight A mm Kg / km 42 51 69 90 122 147 184 220 273 315 375 410 488 562 18.3 19.5 21.9 25.0 29.1 29.4 33.1 39.2 42.9 48.4 53.1 57.9 64.1 69.7 740 860 1155 1630 2220 2520 3200 4645 5870 7555 8985 10760 13480 16215 C212XA1040WMBK08IMR 2250 2860 4240 5290 6475 8055 9735 11780 14435 C435XA1040WMBK08IMR Laid in free air Four Core Cables 46 58 76 98 130 158 185 220 265 305 335 375 435 490 Approx. overall diameter Four Core Cables with Reduced Neutral 0.6690 / 1.4700 0.4940 / 0.9270 0.3430 / 0.6690 0.2480 / 0.4940 0.1970 / 0.3430 0.1600 / 0.3430 0.1290 / 0.2480 0.0990 / 0.1970 0.0810 / 0.1600 158 185 220 265 305 335 375 435 490 122 145 180 210 245 275 310 365 405 147 184 220 273 315 375 410 488 562 27.7 31.3 37.5 41.2 45.3 50.5 55.4 60.3 66.4 AES Code C213XA1040WMBK08IMR C314XA1040WMBK08IMR C315XA1040WMBK08IMR C316XA1040WMBK08IMR C417XA1040WMBK08IMR C418XA1040WMBK08IMR C419XA1040WMBK08IMR C445XA1040WMBK08IMF C446XA1040WMBK08IMF C447XA1040WMBK08IMF C448XA1040WMBK08IMS C449XA1040WMBK08IMS C450XA1040WMBK08IMS C436XA1040WMBK08IMR C437XA1040WMBK08IMR C438XA1040WMBK08IMF C439XA1040WMBK08IMF C440XA1040WMBK08IMF C441XA1040WMBK08IMS C442XA1040WMBK08IMS C443XA1040WMBK08IMS Multi-Core Cables, with Stranded Aluminum Conductors, XLPE Insulated, Steel Wire Armoured and PVC Sheathed CONSTRUCTION Conductor : Stranded circular (rm) or sector shaped (sm) aluminum conductor, as per Class 2 of IEC 60228. Insulation : An extruded layer of Cross linked polyethylene (XLPE) insulation, rated 90 ºC at normal operation to IEC 60502-1. Bedding : An extruded layer of Polyvinyl chloride (PVC). Armouring : Single layer of round galvanized steel wires. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST2 to IEC 60502-1. APPLICATION For outdoor installations in power stations, industrial plants and switchgears if mechanical protection is required or in applications where mechanical damages are expected to occur. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 90 ºC - Max. admissible temperature of conductor at short circuit 250 ºC for 5 seconds DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 90 ºC mm2 Ω / km Ω / km 3.0800 1.9100 1.2000 0.8680 3.9500 2.4500 1.5400 1.1130 10 16 25 35 10 16 25 35 35 rm rm rm rm rm rm rm sm Max. Conductor Resistance 3.0800 1.9100 1.2000 0.8680 3.9500 2.4500 1.5400 1.1130 Current Rating Laid in ground A Laid in ducts A Approx. overall diameter Approx. overall weight A mm Kg / km 60 79 101 131 19.6 21.6 24.2 27.5 635 770 1370 1560 A314XA1020WMBK01IMR 20.5 22.6 27.0 27.3 715 870 1515 1770 A314XA1030WMBK04IMR Laid in free air Two Core Cables 56 73 96 129 47 57 74 105 Three Core Cables 52 67 89 120 41 52 70 95 52 67 89 115 AES Code A315XA1020WMBK01IMR A316XA1020WMBK01IMR A317XA1020WMBK01IMR A315XA1030WMBK04IMR A316XA1030WMBK04IMR A417XA1030WMBK04IMR The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / IEC 60502-1 AL / XLPE / SWA / PVC 0.6 / 1 kV DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 90 ºC mm Ω / km Ω / km 3.0800 1.9100 1.2000 0.8680 0.6410 0.4430 0.3200 0.2530 0.2060 0.1640 0.1250 0.1000 3.9500 2.4500 1.5400 1.1130 0.8220 0.5690 0.4110 0.3250 0.2650 0.2120 0.1630 0.1310 0.8680 / 1.9100 0.6410 / 1.2000 0.4430 / 0.8680 0.3200 / 0.6410 0.2530 / 0.4430 0.2060 / 0.4430 0.1640 / 0.3200 0.1250 / 0.2530 0.1000 / 0.2060 1.1130 / 2.4500 0.8220 / 1.5400 0.5690 / 1.1130 0.4110 / 0.8220 0.3250 / 0.5690 0.2650 / 0.5690 0.2120 / 0.4110 0.1630 / 0.3250 0.1310 / 0.2650 2 10 16 25 35 50 70 95 120 150 185 240 300 35 sm 50 sm 70 sm 95 sm 120 sm 150 sm 185 sm 240 sm 300 sm rm rm rm sm sm sm sm sm sm sm sm sm 16 rm 25 rm 35 sm 50 sm 70 sm 70 sm 95 sm 120 sm 150 sm Max. Conductor Resistance Current Rating Laid in ground A Laid in ducts A 41 52 70 95 110 140 165 190 215 240 280 315 Approx. overall weight A mm Kg / km 52 67 89 115 141 173 210 241 283 320 383 451 21.9 25.0 29.1 29.4 33.1 39.2 42.9 48.4 53.1 57.9 64.1 69.7 785 1335 1630 1700 2330 2760 3340 4320 5080 5990 7220 8440 A314XA1040WMBK08IMR 1500 1870 2600 3090 3690 4700 5550 6560 7820 A435XA1040WMBK08IMR Laid in free air Four Core Cables 52 67 89 120 145 175 210 235 265 290 340 390 Approx. overall diameter Four Core Cables with Reduced Neutral 120 145 175 210 235 265 290 340 390 95 110 140 165 190 215 240 280 315 115 141 173 210 241 283 320 383 451 27.7 31.3 37.5 41.2 45.3 50.5 55.4 60.3 66.4 AES Code A315XA1040WMBK08IMR A316XA1040WMBK08IMR A417XA1040WMBK08IMR A418XA1040WMBK08IMR A419XA1040WMBK08IMR A445XA1040WMBK08IMR A446XA1040WMBK08IMF A447XA1040WMBK08IMF A448XA1040WMBK08IMF A449XA1040WMBK08IMS A450XA1040WMBK08IMS A436XA1040WMBK08IMR A437XA1040WMBK08IMR A438XA1040WMBK08IMR A439XA1040WMBK08IMF A440XA1040WMBK08IMF A441XA1040WMBK08IMF A442XA1040WMBK08IMS A443XA1040WMBK08IMS Control Cables To IEC Standard Control Cables, with Solid Copper Conductors, PVC Insulated and PVC Sheathed CONSTRUCTION Conductor : Plain annealed solid copper conductor, as per Class 1 of IEC 60228. Insulation : An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 ºC at normal operation to IEC 60502-1. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST1 to IEC 60502-1. APPLICATION For use indoors – in cable trenches or ducts; and outdoors - for connecting signaling and control units in industries, railways, traffic signals, power stations, industrial plants and switchgears if mechanical protection is not required, or in applications where the cable is not exposed to mechanical damage. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 70 ºC - Max. admissible temperature of conductor at short circuit 160 ºC for 5 seconds DC at 20 ºC AC at 70 ºC No. X mm Ω / km Ω / km 5 X 1.5 7 X 1.5 10 X 1.5 12 X 1.5 14 X 1.5 16 X 1.5 19 X 1.5 24 X 1.5 30 X 1.5 37 X 1.5 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 2 37 DIMENSIONS AND WEIGHTS ELECTRICAL DATA Number & Nominal cross sectional area Max. Conductor Resistance Current Rating Laid in ground A Laid in ducts A 1.5 mm2 18.0 16.0 14.0 13.0 12.0 11.0 10.0 9.0 8.0 7.5 15.5 14.0 12.5 11.5 10.5 10.0 9.0 8.0 7.5 6.5 Approx. overall diameter Approx. overall weight A mm Kg / km 13.5 12.5 11.5 10.5 9.5 9.0 8.0 7.5 6.5 6.0 11.8 12.7 15.7 16.2 17.0 17.8 18.7 21.7 23.8 24.7 200 250 340 385 435 490 560 700 850 1000 Laid in free air AES Code C108PA10500CBK12IMR C108PA10700CBK21IMR C108PA11000CBK21IMR C108PA11200CBK21IMR C108PA11400CBK21IMR C108PA11600CBK21IMR C108PA11900CBK21IMR C108PA12400CBK21IMF C108PA13000CBK21IMF C108PA13700CBK21IMF The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. CONTROL CABLES / IEC 60502-1 CU / PVC / PVC DC at 20 ºC AC at 70 ºC No. X mm Ω / km Ω / km 5 X 2.5 7 X 2.5 10 X 2.5 12 X 2.5 14 X 2.5 16 X 2.5 19 X 2.5 24 X 2.5 30 X 2.5 37 X 2.5 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 5 X 4.0 7 X 4.0 10 X 4.0 12 X 4.0 14 X 4.0 16 X 4.0 19 X 4.0 24 X 4.0 30 X 4.0 37 X 4.0 DIMENSIONS AND WEIGHTS ELECTRICAL DATA Number & Nominal cross sectional area 2 0.6 / 1 kV Max. Conductor Resistance 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 Current Rating Laid in ground A 24.0 22.0 20.0 18.0 16.0 15.0 14.0 13.0 11.5 10.0 31.0 28.0 25.0 23.0 20.5 19.5 18.0 16.0 14.5 13.0 Laid in ducts A 2.5 mm 2 20.5 18.5 16.5 15.5 14.0 13.0 12.0 11.0 10.0 9.0 4.0 mm2 25.5 23.0 21.0 19.5 17.0 16.0 15.0 13.5 12.0 11.0 Approx. overall diameter Approx. overall weight A mm Kg / km 18.0 16.0 14.5 13.5 12.0 11.0 10.5 9.5 8.5 7.5 12.9 13.8 17.2 17.7 18.6 19.6 20.6 24.0 25.4 27.4 260 330 450 540 600 670 780 1030 1160 1410 C110PA10500CBK12IMR 24.0 21.5 19.5 18.0 16.0 15.0 14.0 12.5 11.0 10.0 15.3 16.5 20.8 21.5 22.6 23.8 25.1 29.6 31.6 34.1 430 480 670 780 890 1000 1170 1460 1830 2320 C112PA10500CBK12IMR Laid in free air AES Code C110PA10700CBK21IMR C110PA11000CBK21IMR C110PA11200CBK21IMR C110PA11400CBK21IMR C110PA11600CBK21IMR C110PA11900CBK21IMR C110PA12400CBK21IMF C110PA13000CBK21IMF C110PA13700CBK21IMF C112PA10700CBK21IMR C112PA11000CBK21IMR C112PA11200CBK21IMR C112PA11400CBK21IMR C112PA11600CBK21IMR C112PA11900CBK21IMR C112PA12400CBK21IMF C112PA13000CBK21IMF C112PA13700CBK21IMF Control Cables, with Stranded Copper Conductors, PVC Insulated and PVC Sheathed CONSTRUCTION Conductor : Plain annealed stranded circular copper conductor, as per Class 2 of IEC 60228. Insulation : An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 ºC at normal operation to IEC 60502-1. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST1 to IEC 60502-1. APPLICATION For use indoors – in cable trenches or ducts; and outdoors - for connecting signaling and control units in industries, railways, traffic signals, power stations, industrial plants and switchgears if mechanical protection is not required, or in applications where the cable is not exposed to mechanical damage. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 70 ºC - Max. admissible temperature of conductor at short circuit 160 ºC for 5 seconds DC at 20 ºC AC at 70 ºC No. X mm Ω / km Ω / km 5 X 1.5 7 X 1.5 10 X 1.5 12 X 1.5 14 X 1.5 16 X 1.5 19 X 1.5 24 X 1.5 30 X 1.5 37 X 1.5 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 2 39 DIMENSIONS AND WEIGHTS ELECTRICAL DATA Number & Nominal cross sectional area Max. Conductor Resistance Current Rating Laid in ground A Laid in ducts A 1.5 mm2 18.0 16.0 14.0 13.0 12.0 11.0 10.0 9.0 8.0 7.5 15.5 14.0 12.5 11.5 10.5 10.0 9.0 8.0 7.5 6.5 Approx. overall diameter Approx. overall weight A mm Kg / km 13.5 12.5 11.5 10.5 9.5 9.0 8.0 7.5 6.5 6.0 12.3 13.3 16.5 17.0 17.8 18.7 19.7 22.9 24.2 26.1 215 265 360 410 465 530 600 740 890 1070 Laid in free air AES Code C208PA10500CBK12IMR C208PA10700CBK21IMR C208PA11000CBK21IMR C208PA11200CBK21IMR C208PA11400CBK21IMR C208PA11600CBK21IMR C208PA11900CBK21IMR C208PA12400CBK21IMF C208PA13000CBK21IMF C208PA13700CBK21IMF The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. CONTROL CABLES / IEC 60502-1 CU / PVC / PVC DC at 20 ºC AC at 70 ºC No. X mm Ω / km Ω / km 5 X 2.5 7 X 2.5 10 X 2.5 12 X 2.5 14 X 2.5 16 X 2.5 19 X 2.5 24 X 2.5 30 X 2.5 37 X 2.5 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 5 X 4.0 7 X 4.0 10 X 4.0 12 X 4.0 14 X 4.0 16 X 4.0 19 X 4.0 24 X 4.0 30 X 4.0 37 X 4.0 DIMENSIONS AND WEIGHTS ELECTRICAL DATA Number & Nominal cross sectional area 2 0.6 / 1 kV Max. Conductor Resistance 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 Current Rating Laid in ground A Laid in ducts 2.5 mm 24.0 22.0 20.0 18.0 16.0 15.0 14.0 13.0 11.5 10.0 A 2 20.5 18.5 16.5 15.5 14.0 13.0 12.0 11.0 10.0 9.0 4.0 mm2 31.0 28.0 25.0 23.0 20.5 19.5 18.0 16.0 14.5 13.0 25.5 23.0 21.0 19.5 17.0 16.0 15.0 13.5 12.0 11.0 Approx. overall diameter Approx. overall weight A mm Kg / km 18.0 16.0 14.5 13.5 12.0 11.0 10.5 9.5 8.5 7.5 13.4 14.5 18.1 18.7 19.6 20.6 21.7 25.3 26.8 28.9 275 350 480 555 630 710 820 1020 1235 1495 C210PA10500CBK12IMR 24.0 21.5 19.5 18.0 16.0 15.0 14.0 12.5 11.0 10.0 16.1 17.4 22.0 22.7 23.9 25.2 26.6 31.4 33.5 36.2 410 520 720 840 950 1070 1260 1580 1965 2510 C212PA10500CBK12IMR Laid in free air AES Code C210PA10700CBK21IMR C210PA11000CBK21IMR C210PA11200CBK21IMR C210PA11400CBK21IMR C210PA11600CBK21IMR C210PA11900CBK21IMR C210PA12400CBK21IMF C210PA13000CBK21IMF C210PA13700CBK21IMF C212PA10700CBK21IMR C212PA11000CBK21IMR C212PA11200CBK21IMR C212PA11400CBK21IMR C212PA11600CBK21IMR C212PA11900CBK21IMR C212PA12400CBK21IMF C212PA13000CBK21IMF C212PA13700CBK21IMF Control Cables, with Solid Copper Conductors, PVC Insulated, Copper Tape Shielded and PVC Sheathed CONSTRUCTION Conductor : Plain annealed solid copper conductor, as per Class 1 of IEC 60228. Insulation : An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 ºC at normal operation to IEC 60502-1. Bedding : An extruded layer of Polyvinyl chloride (PVC). Shielding : Copper tape applied helically with suitable overlap. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST1 to IEC 60502-1. APPLICATION For use indoors – in cable trenches or ducts; and outdoors - for connecting signaling and control units in industries, railways, traffic signals, power stations, industrial plants and switchgears if mechanical protection is not required, or in applications where the cable is not exposed to mechanical damage. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 70 ºC - Max. admissible temperature of conductor at short circuit 160 ºC for 5 seconds 41 DIMENSIONS AND WEIGHTS ELECTRICAL DATA Number & Nominal cross sectional area DC at 20 ºC AC at 70 ºC No. X mm2 Ω / km Ω / km 5 X 1.5 7 X 1.5 10 X 1.5 12 X 1.5 14 X 1.5 16 X 1.5 19 X 1.5 24 X 1.5 30 X 1.5 37 X 1.5 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 Max. Conductor Resistance Current Rating Laid in ground A 18.0 16.0 14.0 13.0 12.0 11.0 10.0 9.0 8.0 7.5 Laid in ducts A 1.5 mm2 15.5 14.0 12.5 11.5 10.5 10.0 9.0 8.0 7.5 6.5 Approx. overall diameter Approx. overall weight A mm Kg / km 13.5 12.5 11.5 10.5 9.5 9.0 8.0 7.5 6.5 6.0 14.2 15.1 18.1 18.6 19.4 20.2 21.1 25.3 27.5 29.4 305 350 465 520 575 635 715 930 1115 1205 Laid in free air AES Code C108PA105N0CBK12IMR C108PA107N0CBK21IMR C108PA110N0CBK21IMR C108PA112N0CBK21IMR C108PA114N0CBK21IMR C108PA116N0CBK21IMR C108PA119N0CBK21IMR C108PA124N0CBK21IMF C108PA130N0CBK21IMF C108PA137N0CBK21IMF The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. CONTROL CABLES / IEC 60502-1 CU / PVC / CT SHIELDED / PVC DC at 20 ºC AC at 70 ºC No. X mm Ω / km Ω / km 5 X 2.5 7 X 2.5 10 X 2.5 12 X 2.5 14 X 2.5 16 X 2.5 19 X 2.5 24 X 2.5 30 X 2.5 37 X 2.5 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 5 X 4.0 7 X 4.0 10 X 4.0 12 X 4.0 14 X 4.0 16 X 4.0 19 X 4.0 24 X 4.0 30 X 4.0 37 X 4.0 DIMENSIONS AND WEIGHTS ELECTRICAL DATA Number & Nominal cross sectional area 2 0.6 / 1 kV Max. Conductor Resistance 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 Current Rating Laid in ground A 24.0 22.0 20.0 18.0 16.0 15.0 14.0 13.0 11.5 10.0 31.0 28.0 25.0 23.0 20.5 19.5 18.0 16.0 14.5 13.0 Laid in ducts A 2.5 mm 2 20.5 18.5 16.5 15.5 14.0 13.0 12.0 11.0 10.0 9.0 4.0 mm2 25.5 23.0 21.0 19.5 17.0 16.0 15.0 13.5 12.0 11.0 Approx. overall diameter Approx. overall weight A mm Kg / km 18.0 16.0 14.5 13.5 12.0 11.0 10.5 9.5 8.5 7.5 15.1 16.2 19.6 20.1 21.0 22.0 23.0 26.4 27.8 30.0 380 450 560 650 750 830 970 1260 1380 1670 C110PA105N0CBK12IMR 24.0 21.5 19.5 18.0 16.0 15.0 14.0 12.5 11.0 10.0 18.5 19.9 23.2 23.9 25.0 26.2 27.5 32.0 34.0 36.7 540 670 800 920 1080 1230 1430 1780 2210 2790 C112PA105N0CBK12IMR Laid in free air AES Code C110PA107N0CBK21IMR C110PA110N0CBK21IMR C110PA112N0CBK21IMR C110PA114N0CBK21IMR C110PA116N0CBK21IMR C110PA119N0CBK21IMR C110PA124N0CBK21IMF C110PA130N0CBK21IMF C110PA137N0CBK21IMF C112PA107N0CBK21IMR C112PA110N0CBK21IMR C112PA112N0CBK21IMR C112PA114N0CBK21IMR C112PA116N0CBK21IMR C112PA119N0CBK21IMR C112PA124N0CBK21IMF C112PA130N0CBK21IMF C112PA137N0CBK21IMF Control Cables, with Stranded Copper Conductors, PVC Insulated, Copper Tape Shielded and PVC Sheathed CONSTRUCTION Conductor : Plain annealed stranded circular copper conductor, as per Class 2 of IEC 60228. Insulation : An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 ºC at normal operation to IEC 60502-1. Bedding : An extruded layer of Polyvinyl chloride (PVC). Shielding : Copper tape applied helically with suitable overlap. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST1 to IEC 60502-1. APPLICATION For use indoors – in cable trenches or ducts; and outdoors - for connecting signaling and control units in industries, railways, traffic signals, power stations, industrial plants and switchgears if mechanical protection is not required, or in applications where the cable is not exposed to mechanical damage. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 70 ºC - Max. admissible temperature of conductor at short circuit 160 ºC for 5 seconds 43 DIMENSIONS AND WEIGHTS ELECTRICAL DATA Number & Nominal cross sectional area DC at 20 ºC AC at 70 ºC No. X mm2 Ω / km Ω / km 5 X 1.5 7 X 1.5 10 X 1.5 12 X 1.5 14 X 1.5 16 X 1.5 19 X 1.5 24 X 1.5 30 X 1.5 37 X 1.5 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 Max. Conductor Resistance Current Rating Laid in ground A 18.0 16.0 14.0 13.0 12.0 11.0 10.0 9.0 8.0 7.5 Laid in ducts A 1.5 mm2 15.5 14.0 12.5 11.5 10.5 10.0 9.0 8.0 7.5 6.5 Approx. overall diameter Approx. overall weight A mm Kg / km 13.5 12.5 11.5 10.5 9.5 9.0 8.0 7.5 6.5 6.0 15.7 16.5 18.9 19.4 20.2 21.1 22.1 25.3 27.5 28.5 340 370 495 550 610 670 760 930 1115 1290 Laid in free air AES Code C208PA105N0CBK12IMR C208PA107N0CBK21IMR C208PA110N0CBK21IMR C208PA112N0CBK21IMR C208PA114N0CBK21IMR C208PA116N0CBK21IMR C208PA119N0CBK21IMR C208PA124N0CBK21IMF C208PA130N0CBK21IMF C208PA137N0CBK21IMF The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. CONTROL CABLES / IEC 60502-1 CU / PVC / CT SHIELDED / PVC DC at 20 ºC AC at 70 ºC No. X mm Ω / km Ω / km 5 X 2.5 7 X 2.5 10 X 2.5 12 X 2.5 14 X 2.5 16 X 2.5 19 X 2.5 24 X 2.5 30 X 2.5 37 X 2.5 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 5 X 4.0 7 X 4.0 10 X 4.0 12 X 4.0 14 X 4.0 16 X 4.0 19 X 4.0 24 X 4.0 30 X 4.0 37 X 4.0 DIMENSIONS AND WEIGHTS ELECTRICAL DATA Number & Nominal cross sectional area 2 0.6 / 1 kV Max. Conductor Resistance 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 Current Rating Laid in ground A 24.0 22.0 20.0 18.0 16.0 15.0 14.0 13.0 11.5 10.0 31.0 28.0 25.0 23.0 20.5 19.5 18.0 16.0 14.5 13.0 Laid in ducts A 2.5 mm 2 20.5 18.5 16.5 15.5 14.0 13.0 12.0 11.0 10.0 9.0 4.0 mm2 25.5 23.0 21.0 19.5 17.0 16.0 15.0 13.5 12.0 11.0 Approx. overall diameter Approx. overall weight A mm Kg / km 18.0 16.0 14.5 13.5 12.0 11.0 10.5 9.5 8.5 7.5 15.8 16.9 20.5 21.1 22.0 23.0 24.1 27.7 26.8 31.5 390 470 630 710 800 875 1000 1225 1240 1750 C210PA105N0CBK12IMR 24.0 21.5 19.5 18.0 16.0 15.0 14.0 12.5 11.0 10.0 18.5 19.9 24.4 25.2 26.3 27.6 29.0 33.8 35.9 38.8 540 670 850 980 1160 1310 1520 1900 2350 2970 C212PA105N0CBK12IMR Laid in free air AES Code C210PA107N0CBK21IMR C210PA110N0CBK21IMR C210PA112N0CBK21IMR C210PA114N0CBK21IMR C210PA116N0CBK21IMR C210PA119N0CBK21IMR C210PA124N0CBK21IMF C210PA130N0CBK21IMF C210PA137N0CBK21IMF C212PA107N0CBK21IMR C212PA110N0CBK21IMR C212PA112N0CBK21IMR C212PA114N0CBK21IMR C212PA116N0CBK21IMR C212PA119N0CBK21IMR C212PA124N0CBK21IMF C212PA130N0CBK21IMF C212PA137N0CBK21IMF Control Cables, with Solid Copper Conductors, PVC Insulated, Steel Tape Armoured and PVC Sheathed CONSTRUCTION Conductor : Plain annealed solid copper conductor, as per Class 1 of IEC 60228. Insulation : An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 ºC at normal operation to IEC 60502-1. Bedding : An extruded layer of Polyvinyl chloride (PVC). Armouring : Double layer of galvanized steel tape. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST1 to IEC 60502-1. APPLICATION For outdoor installations, for connecting signaling and control units in industries, railways, traffic signals, power stations, industrial plants and switchgears if mechanical protection is required, or in applications where mechanical damages are expected to occur. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 70 ºC - Max. admissible temperature of conductor at short circuit 160 ºC for 5 seconds 45 DIMENSIONS AND WEIGHTS ELECTRICAL DATA Number & Nominal cross sectional area DC at 20 ºC AC at 70 ºC No. X mm2 Ω / km Ω / km 5 X 1.5 7 X 1.5 10 X 1.5 12 X 1.5 14 X 1.5 16 X 1.5 19 X 1.5 24 X 1.5 30 X 1.5 37 X 1.5 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 Max. Conductor Resistance Current Rating Laid in ground A 18.0 16.0 14.0 13.0 12.0 11.0 10.0 9.0 8.0 7.5 Laid in ducts A 1.5 mm2 15.5 14.0 12.5 11.5 10.5 10.0 9.0 8.0 7.5 6.5 Approx. overall diameter Approx. overall weight A mm Kg / km 13.5 12.5 11.5 10.5 9.5 9.0 8.0 7.5 6.5 6.0 15.0 15.5 18.5 19.0 20.6 21.0 21.5 24.5 25.8 27.5 355 410 540 590 670 720 800 970 1170 1315 Laid in free air AES Code C108PA1050GCBK12IMR C108PA1070GCBK21IMR C108PA1100GCBK21IMR C108PA1120GCBK21IMR C108PA1140GCBK21IMR C108PA1160GCBK21IMR C108PA1190GCBK21IMR C108PA1240GCBK21IMF C108PA1300GCBK21IMF C108PA1370GCBK21IMF The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. CONTROL CABLES / IEC 60502-1 CU / PVC / STA / PVC DC at 20 ºC AC at 70 ºC No. X mm Ω / km Ω / km 5 X 2.5 7 X 2.5 10 X 2.5 12 X 2.5 14 X 2.5 16 X 2.5 19 X 2.5 24 X 2.5 30 X 2.5 37 X 2.5 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 5 X 4.0 7 X 4.0 10 X 4.0 12 X 4.0 14 X 4.0 16 X 4.0 19 X 4.0 24 X 4.0 30 X 4.0 37 X 4.0 DIMENSIONS AND WEIGHTS ELECTRICAL DATA Number & Nominal cross sectional area 2 0.6 / 1 kV Max. Conductor Resistance 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 Current Rating Laid in ground A 24.0 22.0 20.0 18.0 16.0 15.0 14.0 13.0 11.5 10.0 31.0 28.0 25.0 23.0 20.5 19.5 18.0 16.0 14.5 13.0 Laid in ducts A 2.5 mm 2 20.5 18.5 16.5 15.5 14.0 13.0 12.0 11.0 10.0 9.0 4.0 mm2 25.5 23.0 21.0 19.5 17.0 16.0 15.0 13.5 12.0 11.0 Approx. overall diameter Approx. overall weight A mm Kg / km 18.0 16.0 14.5 13.5 12.0 11.0 10.5 9.5 8.5 7.5 15.5 16.6 20.0 20.5 21.4 22.4 23.4 27.0 28.2 30.5 340 495 650 760 820 920 1030 1260 1520 1830 C110PA1050GCBK12IMR 24.0 21.5 19.5 18.0 16.0 15.0 14.0 12.5 11.0 10.0 18.9 20.3 23.6 24.1 25.4 26.6 28.1 32.6 34.4 37.3 610 710 890 1140 1180 1300 1500 1890 2480 3030 C112PA1050GCBK12IMR Laid in free air AES Code C110PA1070GCBK21IMR C110PA1100GCBK21IMR C110PA1120GCBK21IMR C110PA1140GCBK21IMR C110PA1160GCBK21IMR C110PA1190GCBK21IMR C110PA1240GCBK21IMF C110PA1300GCBK21IMF C110PA1370GCBK21IMF C112PA1070GCBK21IMR C112PA1100GCBK21IMR C112PA1120GCBK21IMR C112PA1140GCBK21IMR C112PA1160GCBK21IMR C112PA1190GCBK21IMR C112PA1240GCBK21IMF C112PA1300GCBK21IMF C112PA1370GCBK21IMF Control Cables, with Stranded Copper Conductors, PVC Insulated, Steel Tape Armoured and PVC Sheathed CONSTRUCTION Conductor : Plain annealed stranded circular copper conductor, as per Class 2 of IEC 60228. Insulation : An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 ºC at normal operation to IEC 60502-1. Bedding : An extruded layer of Polyvinyl chloride (PVC). Armouring : Double layer of galvanized steel tape. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST1 to IEC 60502-1. APPLICATION For outdoor installations, for connecting signaling and control units in industries, railways, traffic signals, power stations, industrial plants and switchgears if mechanical protection is required, or in applications where mechanical damages are expected to occur. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 70 ºC - Max. admissible temperature of conductor at short circuit 160 ºC for 5 seconds DC at 20 ºC AC at 70 ºC No. X mm Ω / km Ω / km 5 X 1.5 7 X 1.5 10 X 1.5 12 X 1.5 14 X 1.5 16 X 1.5 19 X 1.5 24 X 1.5 30 X 1.5 37 X 1.5 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 2 47 DIMENSIONS AND WEIGHTS ELECTRICAL DATA Number & Nominal cross sectional area Max. Conductor Resistance Current Rating Laid in ground A 18.0 16.0 14.0 13.0 12.0 11.0 10.0 9.0 8.0 7.5 Laid in ducts A 1.5 mm 2 15.5 14.0 12.5 11.5 10.5 10.0 9.0 8.0 7.5 6.5 Approx. overall diameter Approx. overall weight A mm Kg / km 13.5 12.5 11.5 10.5 9.5 9.0 8.0 7.5 6.5 6.0 15.3 17.0 19.3 19.8 21.0 21.9 22.5 25.7 27.3 28.9 350 430 570 625 690 800 850 1030 1185 1400 Laid in free air AES Code C208PA1050GCBK12IMR C208PA1070GCBK21IMR C208PA1100GCBK21IMR C208PA1120GCBK21IMR C208PA1140GCBK21IMR C208PA1160GCBK21IMR C208PA1190GCBK21IMR C208PA1240GCBK21IMF C208PA1300GCBK21IMF C208PA1370GCBK21IMF The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. CONTROL CABLES / IEC 60502-1 CU / PVC / STA / PVC DC at 20 ºC AC at 70 ºC No. X mm Ω / km Ω / km 5 X 2.5 7 X 2.5 10 X 2.5 12 X 2.5 14 X 2.5 16 X 2.5 19 X 2.5 24 X 2.5 30 X 2.5 37 X 2.5 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 5 X 4.0 7 X 4.0 10 X 4.0 12 X 4.0 14 X 4.0 16 X 4.0 19 X 4.0 24 X 4.0 30 X 4.0 37 X 4.0 DIMENSIONS AND WEIGHTS ELECTRICAL DATA Number & Nominal cross sectional area 2 0.6 / 1 kV Max. Conductor Resistance 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 Current Rating Laid in ground A 24.0 22.0 20.0 18.0 16.0 15.0 14.0 13.0 11.5 10.0 31.0 28.0 25.0 23.0 20.5 19.5 18.0 16.0 14.5 13.0 Laid in ducts A 2.5 mm 2 20.5 18.5 16.5 15.5 14.0 13.0 12.0 11.0 10.0 9.0 4.0 mm2 25.5 23.0 21.0 19.5 17.0 16.0 15.0 13.5 12.0 11.0 Approx. overall diameter Approx. overall weight A mm Kg / km 18.0 16.0 14.5 13.5 12.0 11.0 10.5 9.5 8.5 7.5 16.2 17.3 20.9 21.5 22.4 23.4 24.5 28.1 30.3 31.9 440 530 710 790 880 970 1090 1340 1630 1875 C210PA1050GCBK12IMR 24.0 21.5 19.5 18.0 16.0 15.0 14.0 12.5 11.0 10.0 19.1 20.4 24.9 25.6 26.7 28.0 29.4 34.4 36.5 39.4 660 740 960 1120 1270 1390 1610 2030 2660 3250 C212PA1050GCBK12IMR Laid in free air AES Code C210PA1070GCBK21IMR C210PA1100GCBK21IMR C210PA1120GCBK21IMR C210PA1140GCBK21IMR C210PA1160GCBK21IMR C210PA1190GCBK21IMR C210PA1240GCBK21IMF C210PA1300GCBK21IMF C210PA1370GCBK21IMF C212PA1070GCBK21IMR C212PA1100GCBK21IMR C212PA1120GCBK21IMR C212PA1140GCBK21IMR C212PA1160GCBK21IMR C212PA1190GCBK21IMR C212PA1240GCBK21IMF C212PA1300GCBK21IMF C212PA1370GCBK21IMF Control Cables, with Solid Copper Conductors, PVC Insulated, Steel Wire Armoured and PVC Sheathed CONSTRUCTION Conductor : Plain annealed solid copper conductor, as per Class 1 of IEC 60228. Insulation : An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 ºC at normal operation to IEC 60502-1. Bedding : An extruded layer of Polyvinyl chloride (PVC). Armouring : Single layer of galvanized steel wires. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST1 to IEC 60502-1. APPLICATION For outdoor installations, for connecting signaling and control units in industries, railways, traffic signals, power stations, industrial plants and switchgears if mechanical protection is required, or in applications where mechanical damages are expected to occur. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 70 ºC - Max. admissible temperature of conductor at short circuit 160 ºC for 5 seconds DC at 20 ºC AC at 70 ºC No. X mm Ω / km Ω / km 5 X 1.5 7 X 1.5 10 X 1.5 12 X 1.5 14 X 1.5 16 X 1.5 19 X 1.5 24 X 1.5 30 X 1.5 37 X 1.5 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 2 49 DIMENSIONS AND WEIGHTS ELECTRICAL DATA Number & Nominal cross sectional area Max. Conductor Resistance Current Rating Laid in ground A 18.0 16.0 14.0 13.0 12.0 11.0 10.0 9.0 8.0 7.5 Laid in ducts A 1.5 mm 2 15.5 14.0 12.5 11.5 10.5 10.0 9.0 8.0 7.5 6.5 Approx. overall diameter Approx. overall weight A mm Kg / km 13.5 12.5 11.5 10.5 9.5 9.0 8.0 7.5 6.5 6.0 16.0 17.2 20.2 22.5 23.3 24.2 25.2 28.0 30.1 33.0 470 530 740 1050 1110 1220 1320 1530 1800 2180 Laid in free air AES Code C108PA1050WCBK12IMR C108PA1070WCBK21IMR C108PA1100WCBK21IMR C108PA1120WCBK21IMR C108PA1140WCBK21IMR C108PA1160WCBK21IMR C108PA1190WCBK21IMR C108PA1240WCBK21IMF C108PA1300WCBK21IMF C108PA1370WCBK21IMF The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. CONTROL CABLES / IEC 60502-1 CU / PVC / SWA / PVC DC at 20 ºC AC at 70 ºC No. X mm Ω / km Ω / km 5 X 2.5 7 X 2.5 10 X 2.5 12 X 2.5 14 X 2.5 16 X 2.5 19 X 2.5 24 X 2.5 30 X 2.5 37 X 2.5 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 5 X 4.0 7 X 4.0 10 X 4.0 12 X 4.0 14 X 4.0 16 X 4.0 19 X 4.0 24 X 4.0 30 X 4.0 37 X 4.0 DIMENSIONS AND WEIGHTS ELECTRICAL DATA Number & Nominal cross sectional area 2 0.6 / 1 kV Max. Conductor Resistance 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 Current Rating Laid in ground A 24.0 22.0 20.0 18.0 16.0 15.0 14.0 13.0 11.5 10.0 31.0 28.0 25.0 23.0 20.5 19.5 18.0 16.0 14.5 13.0 Laid in ducts A 2.5 mm 2 20.5 18.5 16.5 15.5 14.0 13.0 12.0 11.0 10.0 9.0 4.0 mm2 25.5 23.0 21.0 19.5 17.0 16.0 15.0 13.5 12.0 11.0 Approx. overall diameter Approx. overall weight A mm Kg / km 18.0 16.0 14.5 13.5 12.0 11.0 10.5 9.5 8.5 7.5 17.2 18.4 22.9 24.2 25.1 26.1 27.4 30.5 33.7 36.6 570 640 1125 1240 1350 1470 1620 1970 2380 2790 C110PA1050WCBK12IMR 24.0 21.5 19.5 18.0 16.0 15.0 14.0 12.5 11.0 10.0 20.2 22.7 26.3 28.2 29.2 30.8 32.1 37.5 40.4 43.3 750 1150 1460 1650 1790 1980 2150 3010 3430 4020 C112PA1050WCBK12IMR Laid in free air AES Code C110PA1070WCBK21IMR C110PA1100WCBK21IMR C110PA1120WCBK21IMR C110PA1140WCBK21IMR C110PA1160WCBK21IMR C110PA1190WCBK21IMR C110PA1240WCBK21IMF C110PA1300WCBK21IMF C110PA1370WCBK21IMF C112PA1070WCBK21IMR C112PA1100WCBK21IMR C112PA1120WCBK21IMR C112PA1140WCBK21IMR C112PA1160WCBK21IMR C112PA1190WCBK21IMR C112PA1240WCBK21IMF C112PA1300WCBK21IMF C112PA1370WCBK21IMF Control Cables, with Stranded Copper Conductors, PVC Insulated, Steel Wire Armoured and PVC Sheathed CONSTRUCTION Conductor : Plain annealed stranded circular copper conductor, as per Class 2 of IEC 60228. Insulation : An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 ºC at normal operation to IEC 60502-1. Bedding : An extruded layer of Polyvinyl chloride (PVC). Armouring : Single layer of galvanized steel wires. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type ST1 to IEC 60502-1. APPLICATION For outdoor installations, for connecting signaling and control units in industries, railways, traffic signals, power stations, industrial plants and switchgears if mechanical protection is required, or in applications where mechanical damages are expected to occur. TECHNICAL DATA - Nominal voltage Uo/U = 0.6/1 kV - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 70 ºC - Max. admissible temperature of conductor at short circuit 160 ºC for 5 seconds 51 DIMENSIONS AND WEIGHTS ELECTRICAL DATA Number & Nominal cross sectional area DC at 20 ºC AC at 70 ºC No. X mm2 Ω / km Ω / km 5 X 1.5 7 X 1.5 10 X 1.5 12 X 1.5 14 X 1.5 16 X 1.5 19 X 1.5 24 X 1.5 30 X 1.5 37 X 1.5 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 12.1000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 14.6000 Max. Conductor Resistance Current Rating Laid in ground A 18.0 16.0 14.0 13.0 12.0 11.0 10.0 9.0 8.0 7.5 Laid in ducts A 1.5 mm2 15.5 14.0 12.5 11.5 10.5 10.0 9.0 8.0 7.5 6.5 Approx. overall diameter Approx. overall weight A mm Kg / km 13.5 12.5 11.5 10.5 9.5 9.0 8.0 7.5 6.5 6.0 16.6 18.0 21.0 23.3 24.2 25.0 26.0 28.9 31.0 34.0 500 550 770 1080 1140 1260 1370 1620 1850 2250 Laid in free air AES Code C208PA1050WCBK12IMR C208PA1070WCBK21IMR C208PA1100WCBK21IMR C208PA1120WCBK21IMR C208PA1140WCBK21IMR C208PA1160WCBK21IMR C208PA1190WCBK21IMR C208PA1240WCBK21IMF C208PA1300WCBK21IMF C208PA1370WCBK21IMF The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. CONTROL CABLES / IEC 60502-1 CU / PVC / SWA / PVC DC at 20 ºC AC at 70 ºC No. X mm Ω / km Ω / km 5 X 2.5 7 X 2.5 10 X 2.5 12 X 2.5 14 X 2.5 16 X 2.5 19 X 2.5 24 X 2.5 30 X 2.5 37 X 2.5 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 7.4100 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 8.8700 5 X 4.0 7 X 4.0 10 X 4.0 12 X 4.0 14 X 4.0 16 X 4.0 19 X 4.0 24 X 4.0 30 X 4.0 37 X 4.0 DIMENSIONS AND WEIGHTS ELECTRICAL DATA Number & Nominal cross sectional area 2 0.6 / 1 kV Max. Conductor Resistance 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 4.6100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 5.5100 Current Rating Laid in ground A 24.0 22.0 20.0 18.0 16.0 15.0 14.0 13.0 11.5 10.0 31.0 28.0 25.0 23.0 20.5 19.5 18.0 16.0 14.5 13.0 Laid in ducts A 2.5 mm 2 20.5 18.5 16.5 15.5 14.0 13.0 12.0 11.0 10.0 9.0 4.0 mm2 25.5 23.0 21.0 19.5 17.0 16.0 15.0 13.5 12.0 11.0 Approx. overall diameter Approx. overall weight A mm Kg / km 18.0 16.0 14.5 13.5 12.0 11.0 10.5 9.5 8.5 7.5 17.8 19.2 23.8 25.0 26.0 27.0 28.3 31.4 34.5 37.4 600 660 960 1280 1390 1510 1670 2030 2450 2870 C210PA1050WCBK12IMR 24.0 21.5 19.5 18.0 16.0 15.0 14.0 12.5 11.0 10.0 20.8 23.5 27.2 29.0 30.0 31.6 33.0 38.4 41.3 44.5 780 1190 1510 1700 1850 2040 2260 3070 3560 4120 C212PA1050WCBK12IMR Laid in free air AES Code C210PA1070WCBK21IMR C210PA1100WCBK21IMR C210PA1120WCBK21IMR C210PA1140WCBK21IMR C210PA1160WCBK21IMR C210PA1190WCBK21IMR C210PA1240WCBK21IMF C210PA1300WCBK21IMF C210PA1370WCBK21IMF C212PA1070WCBK21IMR C212PA1100WCBK21IMR C212PA1120WCBK21IMR C212PA1140WCBK21IMR C212PA1160WCBK21IMR C212PA1190WCBK21IMR C212PA1240WCBK21IMF C212PA1300WCBK21IMF C212PA1370WCBK21IMF Power Cables To BS Standard Multi-Core Cables, with Stranded Copper Conductors, PVC Insulated, Steel Wire Armoured and PVC Sheathed CONSTRUCTION Conductor : Plain annealed stranded circular (rm) or sector shaped (sm) copper conductor, as per Class 2 of BS EN 60228. Insulation : An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 ºC at normal operation to BS 7655-3.1. Bedding : An extruded layer of Polyvinyl chloride (PVC). Armouring : Single layer of round galvanized steel wires. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type TM1 to BS 7655-4.1. APPLICATION For outdoor installations in power stations, industrial plants and switchgears if mechanical protection is required or in applications where mechanical damages are expected to occur. TECHNICAL DATA - Nominal voltage Uo/U = 600 / 1000 V - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 70 ºC - Max. admissible temperature of conductor at short circuit 160 ºC for 5 seconds DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 70 ºC mm Ω / km Ω / km 2 53 Max. Conductor Resistance 4 6 10 16 25 35 rm rm rm rm rm rm 4.6100 3.0800 1.8300 1.1500 0.7270 0.5240 5.5400 3.6900 2.1900 1.3900 0.8700 0.6280 4 6 10 16 25 35 rm rm rm rm rm sm 4.6100 3.0800 1.8300 1.1500 0.7270 0.5240 5.5400 3.6900 2.1900 1.3900 0.8700 0.6280 Current Rating Laid in ground A Laid in ducts A Approx. overall diameter Approx. overall weight A mm Kg / km 39 50 66 88 116 143 15.1 16.3 19.2 21.2 25.7 27.9 470 560 815 1035 1595 1910 C212PA1020WCBK01BMR 15.8 17.8 20.6 22.8 27.5 26.9 535 735 910 1160 1785 2000 C212PA1030WCBK04BMR Laid in free air Two Core Cables 40 50 65 85 110 130 32 40 55 65 85 105 Three Core Cables 35 45 60 75 100 120 30 36 48 60 80 100 31 39 53 72 94 110 AES Code C213PA1020WCBK01BMR C314PA1020WCBK01BMR C315PA1020WCBK01BMR C316PA1020WCBK01BMR C317PA1020WCBK01BMR C213PA1030WCBK04BMR C314PA1030WCBK04BMR C315PA1030WCBK04BMR C316PA1030WCBK04BMR C417PA1030WCBK04BMR The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / BS 6346 CU / PVC / SWA / PVC 600 / 1000 V DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 70 ºC mm Ω / km Ω / km 4.6100 3.0800 1.8300 1.1500 0.7270 0.5240 0.3870 0.2680 0.1930 0.1530 0.1240 0.0991 0.0754 0.0601 5.5400 3.6900 2.1900 1.3900 0.8700 0.6280 0.4640 0.3220 0.2320 0.1850 0.1510 0.1210 0.0840 0.0770 2 4 6 10 16 25 35 50 70 95 120 150 185 240 300 rm rm rm rm rm sm sm sm sm sm sm sm sm sm Max. Conductor Resistance Current Rating Laid in ground A Laid in ducts A 29 37 50 68 89 95 115 145 165 195 220 245 290 320 Approx. overall weight A mm Kg / km 29 37 50 68 89 116 143 176 215 248 281 319 380 446 17.8 19.0 22.1 25.8 29.9 30.4 35.3 38.9 42.6 47.6 52.1 57.3 63.6 69.7 720 850 1085 1585 2165 2515 3545 4515 5757 Laid in free air Four Core Cables 37 47 63 79 105 120 145 175 210 240 270 300 345 390 Approx. overall diameter 7430 8755 10710 13380 16176 AES Code C212PA1040WCBK08BMR C213PA1040WCBK08BMR C314PA1040WCBK08BMR C315PA1040WCBK08BMR C316PA1040WCBK08BMR C417PA1040WCBK08BMR C418PA1040WCBK08BMR C419PA1040WCBK08BMR C445PA1040WCBK08BMF C446PA1040WCBK08BMF C447PA1040WCBK08BMF C448PA1040WCBK08BMS C449PA1040WCBK08BMS C450PA1040WCBK08BMS Multi-Core Cables, with Stranded Aluminum Conductors, PVC Insulated, Steel Wire Armoured and PVC Sheathed CONSTRUCTION Conductor : Stranded circular (rm) or sector shaped (sm) aluminum conductor, as per Class 2 of BS EN 60228. Insulation : An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 ºC at normal operation to BS 7655-3.1. Bedding : An extruded layer of Polyvinyl chloride (PVC). Armouring : Single layer of round galvanized steel wires. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type TM1 to BS 7655-4.1. APPLICATION For outdoor installations in power stations, industrial plants and switchgears if mechanical protection is required or in applications where mechanical damages are expected to occur. TECHNICAL DATA - Nominal voltage Uo/U = 600 / 1000 V - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 70 ºC - Max. admissible temperature of conductor at short circuit 160 ºC for 5 seconds DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 70 ºC mm Ω / km Ω / km 2 Max. Conductor Resistance 16 25 35 rm rm rm 1.9100 1.2000 0.8680 2.2900 1.4400 1.0430 16 25 35 rm rm sm 1.9100 1.2000 0.8680 2.2900 1.4400 1.0430 Current Rating Laid in ground A Laid in ducts A 46 60 83 Approx. overall weight A mm Kg / km 62 81 115 21.2 25.7 27.9 845 1285 1485 A315PA1020WCBK01BMR 22.8 27.5 26.9 875 1325 1380 A315PA1030WCBK04BMR Laid in free air Two Core Cables 60 77 103 Approx. overall diameter AES Code A316PA1020WCBK01BMR A317PA1020WCBK01BMR Three Core Cables 55 53 70 95 42 56 75 50 66 88 A316PA1030WCBK04BMR A417PA1030WCBK04BMR The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / BS 6346 600 / 1000 V AL / PVC / SWA / PVC DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 70 ºC mm Ω / km Ω / km 1.9100 1.2000 0.8680 0.6410 0.4430 0.3200 0.2530 0.2060 0.1640 0.1250 0.1000 2.2900 1.4400 1.0430 0.7710 0.5330 0.3850 0.3050 0.2490 0.1990 0.1510 0.1230 2 16 25 35 50 70 95 120 150 185 240 300 rm rm sm sm sm sm sm sm sm sm sm Max. Conductor Resistance Current Rating Laid in ground A Laid in ducts A 42 56 75 85 110 130 150 170 195 225 260 Approx. overall weight A mm Kg / km 50 66 88 105 138 165 193 220 253 297 352 25.8 29.9 30.4 35.3 38.9 42.6 47.6 52.1 57.3 63.6 69.7 1205 1550 1695 2405 2915 3490 4530 5255 6170 7450 8815 Laid in free air Four Core Cables 53 70 95 115 135 165 185 210 235 275 310 Approx. overall diameter AES Code A315PA1040WCBK08BMR A316PA1040WCBK08BMR A417PA1040WCBK08BMR A418PA1040WCBK08BMR A419PA1040WCBK08BMR A445PA1040WCBK08BMR A446PA1040WCBK08BMF A447PA1040WCBK08BMF A448PA1040WCBK08BMF A449PA1040WCBK08BMS A450PA1040WCBK08BMS Single-Core Cables, with Stranded Circular Copper Conductors, XLPE Insulated and PVC Sheathed CONSTRUCTION Conductor : Plain annealed stranded circular copper conductor, as per Class 2 of BS EN 60228. Insulation : An extruded layer of Cross linked polyethylene (XLPE) insulation, rated 90 ºC at normal operation to BS 7655-3.1. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type 9 to BS 7655-4.2. APPLICATION For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants and switchgears if mechanical protection is not required, or in applications where the cable is not exposed to mechanical damage. TECHNICAL DATA - Nominal voltage Uo/U = 600 / 1000 V - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 90 ºC - Max. admissible temperature of conductor at short circuit 250 ºC for 5 seconds 57 The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / BS 7889 CU / XLPE / PVC Nominal cross sectional area mm2 50 70 95 120 150 185 240 300 400 500 630 800 1000 600 / 1000 V DIMENSIONS AND WEIGHTS ELECTRICAL DATA Current Rating Laid in ground Laid in free air Max. Conductor Resistance DC at 20 ºC Ω / km 0.3870 0.2680 0.1930 0.1530 0.1240 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283 0.0221 0.0176 AC at 90 ºC Ω / km 0.4940 0.3430 0.2480 0.1970 0.1600 0.1290 0.0990 0.0810 0.0638 0.0517 0.0425 0.0292 0.0234 A 210 263 310 357 394 452 520 588 672 761 872 957 1082 A 200 247 294 336 373 425 488 546 620 693 777 861 935 A 163 200 242 273 310 352 404 457 515 572 651 735 798 A 221 278 347 404 457 530 651 824 893 1008 1155 1313 1449 A 210 268 336 394 446 520 641 756 872 987 1134 1292 1428 A 184 236 289 341 389 441 536 620 714 814 956 1092 1208 Approx. overall diameter Approx. overall weight mm Kg / km 12.9 14.7 16.5 18.0 20.1 22.2 24.9 27.7 30.9 34.9 39.3 43.8 51.5 530 730 980 1225 1490 1870 2420 3020 3855 4985 6290 8090 10075 AES Code C318XA10100MBK51BMR C319XA10100MBK51BMR C345XA10100MBK51BMR C346XA10100MBK51BMR C347XA10100MBK51BMR C348XA10100MBK51BMR C349XA10100MBK51BMR C350XA10100MBK51BMR C351XA10100MBK51BMF C352XA10100MBK51BMF C353XA10100MBK51BMF C354XA10100MBK51BMF C355XA10100MBK51BMF Single-Core Cables, with Stranded Circular Aluminum Conductors, XLPE Insulated and PVC Sheathed CONSTRUCTION Conductor : Stranded circular aluminum conductor, as per Class 2 of BS EN 60228. Insulation : An extruded layer of Cross linked polyethylene (XLPE) insulation, rated 90 ºC at normal operation to BS 7655-3.1. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type 9 to BS 7655-4.2. APPLICATION For use indoors - in cable trenches or ducts; and outdoors - in power stations, industrial plants and switchgears if mechanical protection is not required, or in applications where the cable is not exposed to mechanical damage. TECHNICAL DATA - Nominal voltage Uo/U = 600 / 1000 V - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 90 ºC - Max. admissible temperature of conductor at short circuit 250 ºC for 5 seconds 59 The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / BS 7889 AL / XLPE / PVC Nominal cross sectional area mm2 50 70 95 120 150 185 240 300 400 500 630 800 1000 600 / 1000 V DIMENSIONS AND WEIGHTS ELECTRICAL DATA Current Rating Laid in ground Laid in free air Max. Conductor Resistance DC at 20 ºC Ω / km 0.6410 0.4430 0.3200 0.2530 0.2060 0.1640 0.1250 0.1000 0.0778 0.0605 0.0469 0.0367 0.0291 AC at 90 ºC Ω / km 0.8220 0.5690 0.4110 0.3250 0.2650 0.2120 0.1630 0.1310 0.1000 0.0870 0.0620 0.0560 0.0470 A 163 200 236 278 310 352 410 467 541 609 698 788 872 A 155 189 226 263 294 336 389 436 504 567 646 704 767 A 121 152 179 215 236 267 315 357 410 467 536 599 651 A 173 221 284 326 373 436 515 578 693 809 945 1071 1176 A 168 215 273 315 362 420 499 567 677 788 924 1050 1155 A 147 179 215 242 299 336 399 462 541 630 746 851 966 Approx. overall diameter Approx. overall weight mm Kg / km 12.9 14.7 16.5 18.0 20.1 22.2 24.9 27.7 30.9 34.9 39.3 43.8 51.5 235 310 405 495 605 740 945 1160 1465 1855 2355 2990 3870 AES Code A318XA10100MBK51BMR A319XA10100MBK51BMR A345XA10100MBK51BMR A346XA10100MBK51BMR A347XA10100MBK51BMR A348XA10100MBK51BMR A349XA10100MBK51BMR A350XA10100MBK51BMR A351XA10100MBK51BMR A352XA10100MBK51BMF A353XA10100MBK51BMF A354XA10100MBK51BMF A355XA10100MBK51BMF Multi-Core Cables, with Stranded Copper Conductors, XLPE Insulated, Steel Wire Armoured and PVC Sheathed CONSTRUCTION Conductor : Plain annealed stranded circular (rm) or sector shaped (sm) copper conductor, as per Class 2 of BS EN 60228. Insulation : An extruded layer of Cross linked polyethylene (XLPE) insulation, rated 90 ºC at normal operation to BS 7655-1.3. Bedding : An extruded layer of Polyvinyl chloride (PVC). Armouring : Single layer of round galvanized steel wires. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type 9 to BS 7655-4.2. APPLICATION For outdoor installations in power stations, industrial plants and switchgears if mechanical protection is required or in applications where mechanical damages are expected to occur. TECHNICAL DATA - Nominal voltage Uo/U = 600 / 1000 V - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 90 ºC - Max. admissible temperature of conductor at short circuit 250 ºC for 5 seconds DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 90 ºC mm2 Ω / km Ω / km 4.6100 3.0800 1.8300 1.1500 0.7270 0.5240 5.8800 3.9300 2.3300 1.4700 0.9270 0.6690 4 6 10 16 25 35 4 6 10 16 25 35 61 rm rm rm rm rm rm rm rm rm rm rm sm Max. Conductor Resistance 4.6100 3.0800 1.8300 1.1500 0.7270 0.5240 5.8800 3.9300 2.3300 1.4700 0.9270 0.6690 Current Rating Laid in ground A Laid in ducts A Approx. overall diameter Approx. overall weight A mm Kg / km 47 61 80 106 140 168 14.7 15.7 17.1 19.8 23.2 26.5 445 520 640 930 1290 1770 C212XA1020WMBK01BMR 15.3 16.4 19.1 21.5 26.2 25.7 500 595 815 1065 1665 1865 C212XA1030WMBK04BMR Laid in free air Two Core Cables 51 64 83 107 140 168 41 53 70 84 108 135 Three Core Cables 46 58 76 98 130 158 37 46 61 76 103 122 42 51 69 90 120 147 AES Code C213XA1020WMBK01BMR C314XA1020WMBK01BMR C315XA1020WMBK01BMR C316XA1020WMBK01BMR C317XA1020WMBK01BMR C213XA1030WMBK04BMR C314XA1030WMBK04BMR C315XA1030WMBK04BMR C316XA1030WMBK04BMR C417XA1030WMBK04BMR The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / BS 5467 CU / XLPE / SWA / PVC 600 / 1000 V DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 90 ºC mm Ω / km Ω / km 4.6100 3.0800 1.8300 1.1500 0.7270 0.5240 0.3870 0.2680 0.1930 0.1530 0.1240 0.0991 0.0754 0.0601 5.8800 3.9300 2.3300 1.4700 0.9270 0.6690 0.4940 0.3430 0.2480 0.1970 0.1600 0.1290 0.0990 0.0810 2 4 6 10 16 25 35 50 70 95 120 150 185 240 300 rm rm rm rm rm sm sm sm sm sm sm sm sm sm Max. Conductor Resistance Current Rating Laid in ground A Laid in ducts A 37 46 61 76 103 122 145 180 210 245 275 310 365 405 Approx. overall weight A mm Kg / km 42 51 69 90 122 147 184 220 273 315 375 410 488 562 16.4 18.5 20.4 23.1 28.2 28.7 32.4 37.4 40.1 45.4 49.9 54.9 60.9 66.5 575 795 960 1280 1990 2335 2975 4270 5375 6980 8280 10103 12660 15305 Laid in free air Four Core Cables 46 58 76 98 130 158 185 220 265 305 335 375 435 490 Approx. overall diameter AES Code C212XA1040WMBK08BMR C213XA1040WMBK08BMR C314XA1040WMBK08BMR C315XA1040WMBK08BMR C316XA1040WMBK08BMR C417XA1040WMBK08BMR C418XA1040WMBK08BMR C419XA1040WMBK08BMR C445XA1040WMBK08BMF C446XA1040WMBK08BMF C447XA1040WMBK08BMF C448XA1040WMBK08BMS C449XA1040WMBK08BMS C450XA1040WMBK08BMS Multi-Core Cables, with Stranded Aluminum Conductors, XLPE Insulated, Steel Wire Armoured and PVC Sheathed CONSTRUCTION Conductor : Stranded circular (rm) or sector shaped (sm) aluminum conductor, as per Class 2 of BS EN 60228. Insulation : An extruded layer of Cross linked polyethylene (XLPE) insulation, rated 90 ºC at normal operation to BS 7655-1.3. Bedding : An extruded layer of Polyvinyl chloride (PVC). Armouring : Single layer of round galvanized steel wires. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type 9 to BS 7655-4.2. APPLICATION For outdoor installations in power stations, industrial plants and switchgears if mechanical protection is required or in applications where mechanical damages are expected to occur. TECHNICAL DATA - Nominal voltage Uo/U = 600 / 1000 V - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 90 ºC - Max. admissible temperature of conductor at short circuit 250 ºC for 5 seconds DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 90 ºC mm2 Ω / km Ω / km 1.9100 1.2000 0.8680 2.4500 1.5400 1.1130 16 25 35 rm rm rm Max. Conductor Resistance Current Rating Laid in ground A Laid in ducts A Approx. overall diameter Approx. overall weight A mm Kg / km 79 101 131 19.8 23.2 26.5 740 980 1340 A315XA1020WMBK01BMR 21.5 26.2 25.7 780 1205 1245 A315XA1030WMBK04BMR Laid in free air Two Core Cables 73 96 129 57 74 105 AES Code A316XA1020WMBK01BMR A317XA1020WMBK01BMR Three Core Cables 16 25 35 63 rm rm sm 1.9100 1.2000 0.8680 2.4500 1.5400 1.1130 67 89 120 52 70 95 67 89 115 A316XA1030WMBK04BMR A417XA1030WMBK04BMR The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. POWER CABLES / BS 5467 AL / XLPE / SWA / PVC 600 / 1000 V DIMENSIONS AND WEIGHTS ELECTRICAL DATA Nominal cross sectional area DC at 20 ºC AC at 90 ºC mm Ω / km Ω / km 1.9100 1.2000 0.8680 0.6410 0.4430 0.3200 0.2530 0.2060 0.1640 0.1250 0.1000 2.4500 1.5400 1.1130 0.8220 0.5690 0.4110 0.3250 0.2650 0.2120 0.1630 0.1310 2 16 25 35 50 70 95 120 150 185 240 300 rm rm sm sm sm sm sm sm sm sm sm Max. Conductor Resistance Current Rating Laid in ground A Laid in ducts A 52 70 95 110 140 165 190 215 240 280 315 Approx. overall weight A mm Kg / km 67 89 115 141 173 210 241 283 320 383 451 23.1 28.2 28.7 32.4 37.4 40.1 45.4 49.9 54.9 60.9 66.5 900 1370 1510 1835 2665 3095 4070 4775 5550 6720 7925 Laid in free air Four Core Cables 67 89 120 145 175 210 235 265 290 340 390 Approx. overall diameter AES Code A315XA1040WMBK08BMR A316XA1040WMBK08BMR A417XA1040WMBK08BMR A418XA1040WMBK08BMR A419XA1040WMBK08BMR A445XA1040WMBK08BMR A446XA1040WMBK08BMF A447XA1040WMBK08BMF A448XA1040WMBK08BMF A449XA1040WMBK08BMS A450XA1040WMBK08BMS Control Cables To BS Standard Control Cables, with Stranded Copper Conductors, PVC Insulated, Steel Wire Armoured and PVC Sheathed CONSTRUCTION Conductor : Plain annealed stranded circular copper conductor, as per Class 2 of BS EN 60228. Insulation : An extruded layer of Polyvinyl chloride (PVC) insulation, rated 70 ºC at normal operation to BS 7655-3.1. Bedding : An extruded layer of Polyvinyl chloride (PVC). Armouring : Single layer of galvanized steel wires. Outer sheath : An extruded layer of Polyvinyl chloride (PVC) sheathing compound type TM1 to BS 7655-4.1. APPLICATION For outdoor installations, for connecting signaling and control units in industries, railways, traffic signals, power stations, industrial plants and switchgears if mechanical protection is required, or in applications where mechanical damages are expected to occur. TECHNICAL DATA - Nominal voltage Uo/U = 600 / 1000 V - Power frequency test voltage 3.5 kV for 5 minutes - Max. admissible temperature of conductor at normal operation 70 ºC - Max. admissible temperature of conductor at short circuit 160 ºC for 5 seconds 65 DIMENSIONS AND WEIGHTS ELECTRICAL DATA Number & Nominal cross sectional area DC at 20 ºC AC at 70 ºC No. X mm2 Ω / km Ω / km 7 X 1.5 12 X 1.5 19 X 1.5 27 X 1.5 37 X 1.5 12.1000 12.1000 12.1000 12.1000 12.1000 14.6000 14.6000 14.6000 14.6000 14.6000 Max. Conductor Resistance Current Rating Laid in ground A 16.0 13.0 10.0 8.0 7.5 Laid in ducts A 1.5 mm2 14.0 11.5 9.0 7.5 6.5 Approx. overall diameter Approx. overall weight A mm Kg / km 12.5 10.5 8.0 6.5 6.0 15.6 19.7 22.6 27.1 30.0 490 790 1040 1515 1860 Laid in free air AES Code C208PA1070WCBK21BMR C208PA1120WCBK21BMR C208PA1190WCBK21BMR C208PA1270WCBK21BMF C208PA1370WCBK21BMF The above data is approximate and subject to manufacturing tolerance. We reserve the right to change the above figures as a result of product development and/or changes in standard. CONTROL CABLES / BS 6346 CU / PVC / SWA / PVC DC at 20 ºC AC at 70 ºC No. X mm Ω / km Ω / km 7 X 2.5 12 X 2.5 7.4100 7.4100 8.8700 8.8700 19 X 2.5 27 X 2.5 37 X 2.5 DIMENSIONS AND WEIGHTS ELECTRICAL DATA Number & Nominal cross sectional area 2 600 / 1000 V Max. Conductor Resistance 7.4100 7.4100 7.4100 8.8700 8.8700 8.8700 Current Rating Laid in ground A 22.0 18.0 14.0 11.5 10.0 Laid in ducts A 2.5 mm 2 18.5 15.5 12.0 10.0 9.0 Approx. overall diameter Approx. overall weight A mm Kg / km 16.0 13.5 18.3 22.4 725 1025 Laid in free air 10.5 8.5 7.5 26.9 31.0 34.4 1575 2020 2495 AES Code C210PA1070WCBK21BMR C210PA1120WCBK21BMR C210PA1190WCBK21BMR C210PA1270WCBK21BMF C210PA1370WCBK21BMF 4.0 mm 2 7 X 4.0 12 X 4.0 19 X 4.0 27 X 4.0 37 X 4.0 4.6100 4.6100 4.6100 4.6100 4.6100 5.5100 5.5100 5.5100 5.5100 5.5100 28.0 23.0 18.0 14.5 13.0 23.0 19.5 15.0 12.0 11.0 21.5 18.0 14.0 11.0 10.0 20.9 27.1 31.1 37.1 41.1 940 1570 2115 3110 3840 C212PA1070WCBK21BMR C212PA1120WCBK21BMR C212PA1190WCBK21BMR C212PA1270WCBK21BMF C212PA1370WCBK21BMF Cables For Special Applications Cables For Special Applications Lead Sheathed Cables Construction Main constructions are as explained for low voltage power and control cables in accordance with IEC 60502-1 or BS 6346 / BS 5467 standards. Lead sheath is applied over an extruded bedding layer. Application For outdoor installations in damp and wet locations in chemical and petrol plants in which mechanical protection is required or in applications where mechanical damages are expected to occur. Main properties Radially watertight Corrosion resistant Where necessary, it is available with the longitudinal watertight protection Suitable for use in hostile environment or underground Especially suitable for submarine installation Resistant to aggressive chemical substances Offer good protection against rodents Low Smoke Halogen Free Cables Construction Main constructions are as explained for low voltage power and control cables in accordance with IEC 60502-1 or BS 6724 standards, except that the cables are specially constructed using low smoke, haloge free materials / compounds. Application Low smoke halogen free power cables with enhanced characteristics in case of fire are used for applications where harm to human life and damage to property must be prevented in the event of fire, e.g. in industrial installations, commercial establishments, hotels, airports, underground stations, railway stations, hospitals, banks, schools, etc. Main properties Reduced smoke and toxic gases emission in the event of fire Reduced acid gases emission in the event of fire Excellent flame retardant properties 67 Other Types / Characteristics Various types of constructions can be applied to meet special requirements of the customers, that is: Copper wires screen for control cables Non-magnetic armour (Aluminium) for single-core cables Shielded, armoured and lead sheathed power and control cables Cross linked polyethylene (XLPE) insulation for control cables Polyvinyl chloride (PVC) insulation, rated 85 ºC for power and control cables Fire resistant cables Cables can also be designed for specific requirements, that is: Flexibility Oil resistance UV resistance Termite resistance Hydro-carbon resistance Acid and alkaline resistance Installation in wet locations Flame retardant to IEC 60332-3 or BS EN 50266-2 standards, Category A, B, C or D Other possibilities: Delivery lengths other than standard lengths Products as per other national and international norms/standards Technical Data Recommendations Installation of Cables A. Minimum installation radius None of the low voltage power or control cables should be bent during installation to a radius smaller than the following: All multi-core cables : 12 D All single-core cables : 15 D Where D is the overall diameter of the cable. Wherever possible, larger installation radius should be used, except that the minimum bending radius where the cables are placed in position adjacent to joints and terminations may be reduced to 50% of the above values, provided that the bending is carefully controlled, e.g. by the use of a former. B. Minimum temperature during installation It is recommended that the cables are installed only when both the cable and the ambient temperature are above 0 ºC and have been so for the past 24 hours, or where special precautions have been taken to maintain the cable above this temperature. C. Prevention of moisture ingress Care should be exercised during installation to avoid any damage to cable coverings. This is important in wet or other hostile environments. The protective end cap should not be removed from the ends of the cable until immediately prior to termination or jointing, especially for cables that do not have an extruded bedding. When the caps have been removed, the unprotected ends of the cable should not be exposed to moisture. D. Maximum pulling tension The maximum pulling tension is dependent on the cable design, the mechanical limitations, the conductor material, and the method of laying and pulling the cables. The maximum permissible pulling force can be calculated based on the method of pulling as follows: D.1 Pulling eye attached to the conductor With pulling eye attached to copper conductors, the maximum pulling tension should not exceed 0.036 times circular-mil area of conductor ( Cm). With pulling eye attached to aluminum conductors, the maximum pulling tension should not exceed 0.027 times circular-mil area of conductor (Cm). Or in other words: Tm = 0.036 Tm = 0.027 69 X X n n X X Cm (Copper) Cm (Aluminum) Where Tm : Maximum pulling tension in N n : The number of conductors Cm : Circular mil area of each conductor The maximum limitation for this calculation is 22240 N for single conductor (1/C) cables, and 44480 N for multi-core cables. This limitation is due to unequal distribution of tension forces when pulling multiple conductors. When the calculated pulling tension is close to (or within 10% of) the maximum pulling tension, the use of a tension gauge during the pulling is recommended. D.2 Cable grip over lead sheath With cable grip over lead sheath, with commercial lead, the maximum pulling tension on the lead sheath should not exceed 10.33 N/mm2. D.3 Cable grip over non-leaded cable With cable grip over non-leaded cable, the maximum pulling tension should not exceed 4400 N. E. Sidewall pressure One of the limitations to be considered for the installation of electrical cables is sidewall pressure. The sidewall pressure is the force exerted on the insulation and sheath of the cable at a bend point when the cable is under tension, and is normally the limiting factor in an installation where cable bends are involved. The sidewall pressure in general is expressed as the tension out of a bend expressed in newtons divided by the inside radius of the bend expressed in meters. P= To r Where P : Sidewall pressure in N/m To : Tension leaving the bend in N r : Inside radius of conduit in m The normal maximum sidewall pressure per meter of radius is as given below. However, in order to minimize cable damage due to excessive sidewall pressure, the installer should check the proper recommendations for each type of cables to be installed. Cable type Maximum sidewall pressure ( N/m ) Non-shielded multi-core cables 7300 Armoured cables 4400 Single core cables 7300 Formulas 71 t Material Properties Metals Used For Cables Table 1 ELECTRICAL PROPERTIES Metal Relative Conductivity Copper 100 Electrical Resistivity at 20 ºC Ω .m ( 10-8 ) Temperature Coefficient of Resistance per ºC 100 97 95 – 97 61 8 1.7241 1.7770 1.741 – 1.814 2.8264 21.40 0.00393 0.00393 0.00393 0.00403 0.00400 Copper (Annealed) Copper (Hard drawn) Tinned Copper Aluminum Lead PHYSICAL PROPERTIES Property Unit Copper Kg/m3 ºC x 10-6 ºC W/Cm.ºC Density at 20 ºC Coeff. of thermal expansion Melting point Thermal conductivity Aluminum 8890.0 17.0 1083.0 3.8 2703.0 23.0 659.0 2.4 Lead 11340.0 29.0 327.0 0.34 Insulation Materials Used For Cables Table 2 Properties PVC Nominal Emergency Short Circuit 90 130 250 Mechanical Strength Min. Tensile Strength (N/mm2) Min. Elongation % 12.5 200 12.5 150 4.2 200 Good 2.5 0.93 Good Poor 8.0 1.5 Poor 10 10 10 Excellent 3.0 1.4 Poor Easy Good Easy Good Easy Poor * For sizes > 300 mm2 ** For sizes ≤ 300 mm2 Ω .cm 12 70 95 140 * or 160 ** EPR Rated Temp. Heat deformation at 150 ºC Relative permittivity Specific gravity g/cm3 Solvent resistance Volume Resistivity at max. conductor temperature in normal operation Splicing & termination Environmental stress cracking 73 XLPE 90 130 250 12 10 Derating Factors Table 3 Ground temperature derating factors Max. Conductor Ambient ground temperature ºC temperature ºC 25 30 35 40 45 50 55 70 ºC 1.13 1.07 1.00 0.93 0.85 0.76 0.65 90 ºC 1.09 1.04 1.00 0.95 0.90 0.85 0.80 Table 4 Air temperature derating factors Max. Conductor Ambient air temperature ºC temperature ºC 25 30 35 40 45 50 55 70 ºC 1.22 1.15 1.08 1.00 0.95 0.82 0.71 1.14 1.10 1.05 1.00 0.95 0.89 0.84 90 ºC Table 5 Burial depth derating factors Depth of laying mt. 0.50 Cables cross section Up to 70 mm2 1.00 95 up to 240 mm2 1.00 300 mm 2 & above 1.00 0.60 0.99 0.98 0.97 0.80 0.97 0.96 0.94 1.00 0.95 0.93 0.92 1.25 0.94 0.92 0.89 1.50 0.93 0.90 0.87 1.75 0.92 0.89 0.86 2.00 0.91 0.88 0.85 Derating Factors Table 6 Soil thermal resistivity derating factors Soil thermal resistivity ºC.m / Watt Rating factor 0.8 0.9 1.0 1.2 1.5 2.0 2.5 1.17 1.12 1.07 1.00 0.91 0.80 0.73 Table 7 PVC rated temperature derating factors PVC rated temperature ºC Rating factor 70 85 95 105 1.000 1.195 1.309 1.414 Table 8 Trefoil or flat formation derating factors for three single core cables laid direct in ground Spacing Number Spacing Spacing Spacing of Trefoil formation circuits 75 Touching Flat formation Spacing = 0.15 Mt. Spacing = 0.30 Mt. Trefoil Flat Trefoil Flat Trefoil Flat 2 0.77 0.80 0.82 0.85 0.88 0.91 3 0.66 0.69 0.73 0.76 0.80 0.83 4 0.60 0.63 0.68 0.71 0.74 0.77 5 0.56 0.59 0.64 0.67 0.72 0.75 6 0.53 0.57 0.61 0.64 0.70 0.73 Table 9 Flat formation derating factors for three single core cables laid in free air Laid on the ground Clearance = cable diameter ( d ) Clearance from the wall > 2 cm Rating factor Number of circuits 1 2 3 0.92 0.89 0.88 Laid on cables troughs Clearance = cable diameter ( d ) Clearance from the wall > 2 cm ( circulation of air is restricted ) Number of circuits 1 2 3 1 0.92 0.89 0.88 2 0.87 0.84 0.83 Number of troughs 3 0.84 0.82 0.81 6 0.82 0.80 0.79 Laid on cables racks Clearance = cable diameter ( d ) Clearance from the wall > 2 cm Number of racks Number of circuits 1 2 3 1 1.00 0.97 0.96 2 0.97 0.94 0.93 3 0.96 0.93 0.92 6 0.94 0.91 0.90 Arranged near the wall Number of circuits Clearance = cable diameter ( d ) Clearance from the wall > 2 cm 1 2 3 Rating factor 0.94 0.91 0.89 Arranged on the wall Clearance = cable diameter ( d ) Rating factor Number of circuits 1 2 3 0.89 0.86 0.84 Derating Factors Table 10 Trefoil touching formation derating factors for three single core cables laid in free air Laid on the ground Clearance = 2 cable diameter ( 2d ) Clearance from the wall > 2 cm Rating factor Number of circuits 1 2 3 0.95 0.90 0.88 Laid on cables troughs Clearance = 2 cable diameter ( 2d ) Clearance from the wall > 2 cm ( circulation of air is restricted ) Number of circuits Number of troughs 1 2 3 1 0.95 0.90 0.88 2 0.90 0.85 0.83 3 0.88 0.83 0.81 6 0.86 0.81 0.79 Laid on cables racks Clearance = 2 cable diameter ( 2d ) Clearance from the wall > 2 cm Number of racks Number of circuits 1 2 3 1 1.00 0.98 0.96 2 1.00 0.95 0.93 3 1.00 0.94 0.92 6 1.00 0.93 0.90 Arrangement for zero reduction Clearance = 4 cable diameter ( 4d ) Clearance from the wall > 2 cm Rating factor 77 Number of circuits 1 2 3 1.00 1.00 1.00 Table 11 Horizontal or vertical formation derating factors for multi-core cables laid in free air Laid on the ground Clearance = cable diameter ( d ) Clearance from the wall > 2 cm Rating factor Number of circuits 1 2 3 6 9 0.95 0.90 0.88 0.85 0.84 Laid on cables troughs ( circulation of air is restricted ) Clearance = cable diameter ( d ) Clearance from the wall > 2 cm Number of circuits 1 2 3 6 9 1 0.95 0.90 0.88 0.85 0.84 Number of troughs 2 0.90 0.85 0.83 0.81 0.80 3 0.88 0.83 0.81 0.79 0.78 6 0.86 0.81 0.79 0.77 0.76 Laid on cables racks Clearance = cable diameter ( d ) Clearance from the wall > 2 cm Number of circuits 1 Number of racks 2 3 6 9 1 1.00 0.98 0.96 0.93 0.92 2 1.00 0.95 0.93 0.90 0.89 3 1.00 0.94 0.92 0.89 0.88 6 1.00 0.93 0.90 0.87 0.86 Arranged near the wall Number of circuits Clearance = cable diameter ( d ) Clearance from the wall > 2 cm 1 2 3 6 9 Rating factor 1.00 0.93 0.90 0.87 0.86 Arrangement for zero reduction Number of circuits Clearance = 2 cable diameter ( 2d ) Clearance from the wall > 2 cm 1 2 3 6 9 Rating factor 1.00 1.00 1.00 1.00 1.00 Derating Factors Table 12 Derating factors for multi-core cables touching and in contact with the wall in air Laid on the ground Number of circuits Cables are touched together and in contact with the wall 1 2 3 6 9 Rating factor 0.90 0.84 0.80 0.75 0.73 Laid on cables troughs ( circulation of air is restricted ) Cables are touched together and in contact with the wall Number of circuits 1 2 3 6 9 1 0.95 0.84 0.80 0.75 0.73 2 0.95 0.80 0.76 0.71 0.69 3 0.95 0.78 0.74 0.70 0.68 6 0.95 0.76 0.72 0.68 0.66 Number of troughs Laid on cables racks Cables are touched together and in contact with the wall Number of circuits 1 2 3 6 9 1 0.95 0.84 0.80 0.75 0.73 2 0.95 0.80 0.76 0.71 0.69 3 0.95 0.78 0.74 0.70 0.68 6 0.95 0.76 0.72 0.68 0.66 Number of racks Arranged on the wall 79 Number of circuits Cables are touched together and in contact with the wall 1 2 3 6 9 Rating factor 0.95 0.78 0.73 0.68 0.66 Short Circuit Current Table 13 Max. short circuit temperature for cable components Material Cable component Insulation PVC Insulation Sheathing Max. short circuit temp. ºC 140 For C.S.A > 300 mm 2 2 160 For C.S.A > 300 mm XLPE Insulation 250 PVC Sheath 200 LDPE Sheath 150 HDPE Sheath 180 Lead Sheath 170 Lead Alloy Sheath 200 Table 14 kA short circuit current - copper conductor - PVC insulated C.S.A 2 mm 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 1000 Short circuit duration sec. 0.1 0.55 0.91 1.45 2.18 3.6 5.8 9.1 12.7 18.2 25.5 34.5 43.6 54.5 67.3 87.3 109.1 130.0 162.5 204.8 260.1 325.1 0.2 0.39 0.64 1.03 1.54 2.6 4.1 6.4 9.0 12.9 18.0 24.4 30.9 38.6 47.6 61.7 77.1 91.9 114.9 144.8 183.9 229.9 0.3 0.31 0.52 0.84 1.26 2.1 3.4 5.2 7.3 10.5 14.7 19.9 25.2 31.5 38.8 50.4 63.0 75.1 93.8 118.2 150.1 187.7 0.4 0.27 0.45 0.73 1.09 1.8 2.9 4.5 6.4 9.1 12.7 17.3 21.8 27.3 33.6 43.6 54.5 65.0 81.3 102.4 130.0 162.5 0.5 0.24 0.41 0.65 0.98 1.6 2.6 4.1 5.7 8.1 11.4 15.5 19.5 24.4 30.1 39.0 48.8 58.2 72.7 91.6 116.3 145.4 1.0 0.17 0.29 0.46 0.69 1.2 1.8 2.9 4.0 5.8 8.1 10.9 13.8 17.3 21.3 27.6 34.5 41.1 51.4 64.8 82.2 102.8 2.0 0.12 0.20 0.33 0.49 0.8 1.3 2.0 2.8 4.1 5.7 7.7 9.8 12.2 15.0 19.5 24.4 29.1 36.3 45.8 58.2 72.7 3.0 0.10 0.17 0.27 0.40 0.7 1.1 1.7 2.3 3.3 4.6 6.3 8.0 10.0 12.3 15.9 19.9 23.7 29.7 37.4 47.5 59.4 4.0 0.09 0.14 0.23 0.35 0.6 0.9 1.4 2.0 2.9 4.0 5.5 6.9 8.6 10.6 13.8 17.3 20.6 25.7 32.4 41.1 51.4 5.0 0.08 0.13 0.21 0.31 0.5 0.8 1.3 1.8 2.6 3.6 4.9 6.2 7.7 9.5 12.3 15.4 18.4 23.0 29.0 36.8 46.0 Short Circuit Current Table 15 kA short circuit current - aluminum conductor - PVC insulated C.S.A mm 2 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 1000 Short circuit duration sec. 0.1 3.8 6.0 8.4 12.0 16.8 22.8 28.8 36.0 44.5 57.7 72.1 86.0 107.5 135.5 172.0 215.0 0.2 2.7 4.2 5.9 8.5 11.9 16.1 20.4 25.5 31.4 40.8 51.0 60.8 76.0 95.8 121.6 152.1 0.3 2.2 3.5 4.9 6.9 9.7 13.2 16.7 20.8 25.7 33.3 41.6 49.7 62.1 78.2 99.3 124.2 0.4 1.9 3.0 4.2 6.0 8.4 11.4 14.4 18.0 22.2 28.8 36.0 43.0 53.8 67.7 86.0 107.5 0.5 1.7 2.7 3.8 5.4 7.5 10.2 12.9 16.1 19.9 25.8 32.2 38.5 48.1 60.6 76.9 96.2 1.0 1.2 1.9 2.7 3.8 5.3 7.2 9.1 11.4 14.1 18.2 22.8 27.2 34.0 42.8 54.4 68.0 2.0 0.9 1.3 1.9 2.7 3.8 5.1 6.4 8.1 9.9 12.9 16.1 19.2 24.0 30.3 38.5 48.1 3.0 0.7 1.1 1.5 2.2 3.1 4.2 5.3 6.6 8.1 10.5 13.2 15.7 19.6 24.7 31.4 39.3 4.0 0.6 1.0 1.3 1.9 2.7 3.6 4.6 5.7 7.0 9.1 11.4 13.6 17.0 21.4 27.2 34.0 5.0 0.5 0.8 1.2 1.7 2.4 3.2 4.1 5.1 6.3 8.2 10.2 12.2 15.2 19.2 24.3 30.4 Table 16 kA short circuit current - aluminum conductor - XLPE insulated C.S.A mm 2 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 1000 81 Short circuit duration sec. 0.1 4.7 7.4 10.4 14.8 20.7 28.1 35.6 44.4 54.8 71.1 88.9 118.5 148.2 186.7 237.0 296.3 0.2 3.4 5.2 7.3 10.5 14.7 19.9 25.1 31.4 38.8 50.3 62.9 83.8 104.8 132.0 167.6 209.5 0.3 2.7 4.3 6.0 8.6 12.0 16.3 20.5 25.7 31.6 41.1 51.3 68.4 85.5 107.8 136.9 171.1 0.4 2.4 3.7 5.2 7.4 10.4 14.1 17.8 22.2 27.4 35.6 44.4 59.3 74.1 93.3 118.5 148.2 0.5 2.1 3.3 4.6 6.6 9.3 12.6 15.9 19.9 24.5 31.8 39.8 53.0 66.3 83.5 106.0 132.5 1.0 1.5 2.3 3.3 4.7 6.6 8.9 11.2 14.1 17.3 22.5 28.1 37.5 46.9 59.0 75.0 93.7 2.0 1.1 1.7 2.3 3.3 4.6 6.3 8.0 9.9 12.3 15.9 19.9 26.5 33.1 41.7 53.0 66.3 3.0 0.9 1.4 1.9 2.7 3.8 5.1 6.5 8.1 10.0 13.0 16.2 21.6 27.0 34.1 43.3 54.1 4.0 0.75 1.2 1.6 2.3 3.3 4.5 5.6 7.0 8.7 11.2 14.1 18.7 23.4 29.5 37.5 46.9 5.0 0.67 1.0 1.5 2.1 2.9 4.0 5.0 6.3 7.8 10.1 12.6 16.8 21.0 26.4 33.5 41.9 Table 17 kA short circuit current - copper conductor - XLPE insulated C.S.A mm 2 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 1000 Short circuit duration sec. 0.1 0.7 1.1 1.8 2.7 4.5 7.2 11.3 15.8 22.6 31.7 43.0 54.3 67.8 83.7 108.5 135.7 180.9 226.1 284.9 361.8 452.2 0.2 0.5 0.8 1.3 1.9 3.2 5.1 8.0 11.2 16.0 22.4 30.4 38.4 48.0 59.2 76.7 95.9 127.9 159.9 201.4 255.8 319.8 0.3 0.4 0.7 1.0 1.6 2.6 4.2 6.5 9.1 13.1 18.3 24.8 31.3 39.2 48.3 62.7 78.3 104.4 130.5 164.5 208.9 261.1 0.4 0.3 0.6 0.9 1.4 2.3 3.6 5.7 7.9 11.3 15.8 21.5 27.1 33.9 41.8 54.3 67.8 90.4 113.1 142.4 180.9 226.1 0.5 0.3 0.5 0.8 1.2 2.0 3.2 5.1 7.1 10.1 14.2 19.2 24.3 30.3 37.4 48.5 60.7 80.9 101.1 127.4 161.8 202.2 1.0 0.21 0.36 0.57 0.86 1.4 2.3 3.6 5.0 7.2 10.0 13.6 17.2 21.5 26.5 34.3 42.9 57.2 71.5 90.1 114.4 143.0 2.0 0.15 0.25 0.40 0.61 1.0 1.6 2.5 3.5 5.1 7.1 9.6 12.1 15.2 18.7 24.3 30.3 40.4 50.6 63.7 80.9 101.1 3.0 0.12 0.21 0.33 0.50 0.8 1.3 2.1 2.9 4.1 5.8 7.8 9.9 12.4 15.3 19.8 24.8 33.0 41.3 52.0 66.0 82.6 4.0 0.11 0.18 0.29 0.43 0.7 1.1 1.8 2.5 3.6 5.0 6.8 8.6 10.7 13.2 17.2 21.5 28.6 35.8 45.0 57.2 71.5 5.0 0.10 0.16 0.26 0.38 0.6 1.0 1.6 2.2 3.2 4.5 6.1 7.7 9.6 11.8 15.3 19.2 25.6 32.0 40.3 51.2 64.0 Voltage Drop Table 18 Voltage drop for single core LV cables C.S.A mm2 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 C.S.A mm 2 16 25 35 50 70 95 120 150 185 240 300 400 500 630 Copper Conductors Voltage drop ( mV / Amp / Meter ) XLPE Insulated & PVC Sheathed PVC 85 º C Insulated & PVC Sheathed Flat Trefoil 22.6 22.5 13.9 13.8 8.7 8.7 5.9 5.48 3.5 3.5 2.3 2.2 1.5 1.5 1.1 1.1 0.83 0.82 0.61 0.60 0.47 0.45 0.39 0.38 0.34 0.33 0.29 0.28 0.25 0.24 0.22 0.21 0.20 0.18 0.18 0.17 0.16 0.15 Trefoil 22.8 14.1 8.8 5.9 3.6 2.3 1.5 1.1 0.83 0.60 0.46 0.38 0.33 0.28 0.24 0.21 0.18 0.16 0.15 Aluminum Conductors Voltage drop ( mV / Amp / Meter ) PVC 85 ºC Insulated & PVC Sheathed Flat Trefoil 3.7 3.7 2.4 2.3 1.7 1.7 1.3 1.3 0.94 0.92 0.71 0.69 0.58 0.56 0.49 0.48 0.41 0.40 0.34 0.33 0.29 0.28 0.25 0.24 0.22 0.21 0.19 0.18 The above data is based on the following : Max. operating temp : 90 ºC for XLPE & 85 ºC for PVC Power factor : 0.85 Rated frequency : 60 Hz 83 Flat 22.9 14.1 8.8 5.9 3.6 2.3 1.5 1.1 0.84 0.61 0.47 0.39 0.34 0.29 0.25 0.22 0.19 0.17 0.16 XLPE Insulated & PVC Sheathed Flat 3.7 2.4 1.8 1.3 0.95 0.71 0.58 0.5 0.42 0.34 0.29 0.25 0.22 0.19 Trefoil 3.7 2.4 1.7 1.3 0.93 0.70 0.57 0.48 0.40 0.33 0.28 0.24 0.21 0.18 Table 19 Voltage drop for multi core LV cables C.S.A mm2 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 C.S.A 2 mm 16 25 35 50 70 95 120 150 185 240 300 400 500 Copper Conductors Voltage drop ( mV / Amp / Meter ) XLPE Insulated & PVC Sheathed PVC 85 º C Insulated & PVC Sheathed 22.5 13.8 8.6 5.8 3.5 2.2 1.4 1.1 0.8 0.58 0.44 0.37 0.32 0.27 0.23 0.20 0.18 0.15 22.8 14.0 8.7 5.9 3.5 2.2 1.5 1.1 0.81 0.58 0.44 0.37 0.31 0.27 0.23 0.2 0.18 0.15 Aluminum Conductors Voltage drop ( mV / Amp / Meter ) XLPE Insulated & PVC Sheathed PVC 85 ºC Insulated & PVC Sheathed 3.6 2.3 1.7 1.3 0.91 0.68 0.55 0.47 0.39 0.32 0.27 0.23 0.20 The above data is based on the following : Max. operating temp: 90 ºC for XLPE & 85 ºC for PVC Power factor : 0.85 Rated frequency : 60 Hz 3.7 2.4 1.7 1.3 0.92 0.68 0.56 0.47 0.39 0.32 0.27 0.23 0.20 Coding Key 1 2 3 4 5 6 The type designation provides information on the type of cable, the conductor material, the insulation and sheath materials, the no. of cores, and the principle design features in abbreviated and simplified form. The type designation is made up of 19 digits or characters. The type of the conductor is specified first and then the cable construction from inside to outside. You can order our product either by giving the AES item code stated in the catalogue or if the required cable construction is not included in our catalogue, you can use the following codes to determine the type of cable you require. 1. Type of conductor material C: Copper A: Aluminum 2. Type of conductor 1: 2: 3: 4: 5: 6: Solid Stranded - Circular round Stranded - Circular compacted Stranded - Sector shaped Flexible Extra-flexible 3 & 4. Size of conductor 08 : 10 : 12 : 13 : 14 : 15 : 16 : 17 : 18 : 19 : 32 : 33 : 34 : 35 : 36 : 37 : 38 : 39 : 40 : 41 : 42 : 43 : 44 : 45 : 85 1.5 mm2 2.5 mm2 4 mm2 6 mm2 10 mm2 16 mm2 25 mm2 35 mm2 50 mm2 70 mm2 3 x 10 + 6 mm2 3 x 16 + 10 mm2 3 x 25 + 16 mm2 3 x 35 + 16 mm2 3 x 50 + 25 mm2 3 x 70 + 35 mm2 3 x 95 + 50 mm2 3 x 120 + 70 mm2 3 x 150 + 70 mm2 3 x 185 + 95 mm2 3 x 240 + 120 mm2 3 x 300 + 150 mm2 3 x 400 + 185 mm2 95 mm2 7 8 9 10 11 12 13 14 15 16 17 18 19 46 : 120 mm2 X: Lead + Aluminum wire armoured 47 : 48 : 49 : 50 : 51 : 52 : 53 : 54 : 55 : 150 mm2 185 mm2 240 mm2 300 mm2 400 mm2 500 mm2 630 mm2 800 mm2 1000 mm2 R: Lead + Aluminum tape armoured 5. Type of insulation material X: P: H: XLPE Insulation PVC Insulation rated 70 ºC PVC Insulation rated 85 ºC 6. Rated voltage A: 0.6 / 1 kV 7. Cable construction 1: 2: Cores Pairs 8 & 9. Number of cores 01 : 1 Core 02 : 03 : 04 : 05 : 2 Cores 3 Cores 4 Cores 5 Cores ≈ ≈ 37 : 37 Cores 10. Shielding N: C: Copper tape Copper wires 0: Without shielding 11. Armouring 0: L: N: A: B: G: W: Without armouring Pure lead sheathed Lead alloy sheathed Aluminum wire armoured Aluminum tape armoured Galvanized steel tape armoured Galvanized steel wire armoured T: S: Non-Galva. steel tape armoured Lead + G. steel tape armoured Lead + G. steel wire armoured D: 12. Outer sheath material C: M: L: PVC Sheath rated 80 ºC PVC Sheath rated 90 ºC LSHF Sheath rated 90 ºC 13 & 14. Outer sheath color BK : Black RD : GY : GR : YG : GL : Red Grey Green Yellow / Green Green / Yellow 15 & 16. Core identification 51 : 1C - Red 01 : 04 : 08 : 12 : 21 : 2C - Red, Black 3C - Red, Yellow, Blue 4C - Red, Yellow, Blue, Black 5C - Red, Yellow, Blue, Black, G/Y 6C & Above - Black + No. Note: The mentioned colors are the most common for core identification. However, any other colors for core identification can be used upon a customer’s request. 17. Design standard I: B: C: IEC Standard BS Standard Customer request 18. Packing type M: T: Wooden drum Steel drum 19. Cutting length S: F: R: 250 Meter 500 Meter 1000 Meter Note: The mentioned cutting lengths are the most common. However, any other cutting lengths can be supplied as per a customer’s drum schedule. Selection of Conductor Cross-section Conductor cross–section should be selected with a sustained current rating under the conditions of installation not less than the maximum current it will be required to carry during normal operation, and a short circuit current rating adequate for the prospective short–circuit current and time for which it may persist. Especially in low–voltage networks, it is necessary to check the conductor cross-section, chosen with respect to the current carrying capacity, by the permissible voltage drop. It is also recommended to carry out this check for long connections in medium and high voltage networks. Example for selection of conductor cross-section 0.05 MVA at an operating voltage of 380V have to be transmitted by 4 cores cable with copper conductor, XLPE insulated and PVC sheathed direct buried in the ground under the following laying conditions : Burial depth Soil thermal resistivity Ambient ground temp. Cable route length : : : : 0.5 1.2 35 50 m K.m/W ºC m Calculating cross-section according to load current The load current can be calculated based on the following formula : I= Sx10 6 3 xU = 0.05 x10 6 3 x380 = 76 A Where I : Load current in A S : KVA rating U : Line voltage in volts According to the relevant current carrying capacity values for the used cable type, it has been found that the current carrying capacity value for 4 X 16 mm2 cable under the required installation conditions is 97A, which is greater than the required load current (76A). So, cable 4 X 16 mm2 can be used to carry the required load current. Calculating cross-section according to voltage drop The tabulated voltage drop values in this catalogue are based on a load power factor of 85% lagging and given for a current one ampere for a one meter run. For any cable length, the values should be multiplied by the cable route length in meters and by the load current in amperes. The applicable formula to calculate the approximate voltage drop/ampere/meter is the following : V ap = V p x1000 IxL mV/Amp/Meter Where Vap I L Vp : : : : Approximate voltage drop/ampere/meter Load current in A Cable route length Maximum permissible voltage drop (say 2.5% of 380 V) By substituting current, cable route length, and maximum permissible voltage drop. Vap = 9.5 x1000 = 2.5 mV/Amp/Meter 76 x50 To determine a suitable size of conductor, select a cable from the voltage drop tables, such that the selected voltage drop value from the tables is less than the calculated value of 2.5 mv/amp/m. Also ensure that it will carry the desired current. In this example, the nearest voltage drop value is 2.2 mv/amp/m, which is corresponding to size 16 mm2. In situations where the load power factor is other than 85% lagging, the voltage drop equations shown in the formula section should be used to calculate the voltage drop. Weight-Imperial v v Weight-Metric Length-Metric Miscellaneous-Imperial Area-Imperial Miscellaneous-Metric Area-Metric centimeters Volume-Imperial 4.54609 Temperature Lenght-Imperial 87 Volume-U.S. Volume-Metric Certificates 1. BASEC (BRITISH APPROVALS SERVICE FOR CABLES) a. Certificate of conformity, ISO 9001–2008 b. Certification Schedule 2. Type Test Certificates Certificates a. Bare soft copper conductor b. Power cable with extruded insulation with rated voltage of 0.6 / 1KV Applicable Standards a. IEC 60228: 2004 b. IEC 60502-1: 2004 c. IEC 60332-1-2: 2004 d. IEC 60332-3-24: 2000 (Category C) e. IEC 60332-3-22: 2000 (Category A) Product Range manufactures a wide range of low, medium and high voltage electrical products under 50 categories. Listed below is ’s comprehensive product classification: POWER & CONTROL Low Voltage Products • Load Center • Circuit Breaker Enclosures (Indoor – Outdoor) • Busbar Chamber with Main / Outdoor • Breakers Low Voltage Systems • Switch Boards – MF Type • Distribution Boards – MB Type • Motor Control Centres • Capacitor Banks – Power Factor Correction Panels • Automatic Transfer Switch (ATS Panels) • Distribution Boards for Substations • Synchronizing Panels • Control & Automation Panels Package & Unit Substations • Indoor Package Substation • Outdoor Package Substation • Indoor Unit Substation • Outdoor Unit Substation Medium Voltage Systems • Switchgear (Metal clad, Metal enclosed) • Control gear • Ring Main Unit (RMU) • Retrofit solution METAL ENCLOSURES Service Box Enclosures Modular Enclosures Extendable Cubicles Telephone Box Busbar Chamber w/o Main METAL ACCESSORIES Switch Boxes Junction Boxes 89 CABLES & WIRES Building Wires • American Standards (UL) • British Standards (BS) • International Electro-technical Commission Standards (IEC) • Low Smoke, Halogen Free Wires Overhead conductors • Bare Stranded Soft Drawn Copper Conductors (SDC) • Bare Stranded Hard Drawn Copper Conductors (HDC) • All Aluminum Conductors (AAC) • All Aluminum Alloy Conductors (AAAC) • Aluminum Conductors, Steel Reinforced (ACSR) • Aluminum Conductors, Aluminum-Clad Steel Reinforced (ACSR / AW) • Aluminum Conductors, Aluminum-Alloy Reinforced (ACAR) • Weather Resistant XLPE Insulated Service Drop Cables Power Cables • Low Voltage Power & Control Cables • Low Smoke, Halogen Free Cables • Cables for Special Applications Signal, Communication & Data Cables • Telephone Cables • Coaxial Cables (RG6 / U) • Local Area Network Cables (LAN) LIGHTING Halogen Florescent Energy Saving COMMUNICATION SYSTEMS Audio Intercom Contact us markets and sells over 800 electrical construction products in the Saudi Arabian markets and exports them to several countries in the Middle East, Europe, Asia and Africa. Through our several operational domains and a widespread network of distributors, we ensure uninterrupted supply of products. We also provide solutions to our clients including end-users, project owners, engineering contractors and consultants. ’s highly-qualified engineers, sales & marketing teams not only cater to its customers’ requirements efficiently, they also manage prompt after-sales services and extend full technical support and consultancy services to them. For more information contact us: Toll-free No. 800 124 0026 Email: [email protected] Website: www.alfanar.com 91
Similar documents
DIZAJNOVÉ VYPÍNAČE A SVIETIDLÁ CJC SYSTEMS DIZAJNOVÉ
all single elements are to be assembled in the right order to obtain the final switch panel in universal built-in boxes with screws horizontal: sockets not included
More information5. BALKAN VETERANLARI ATLETiZM §AMPiYONASI
Ertugrul OGULBULAN Xristod BRADIS Ahmet TULGAR Ismail KOMBl Pavtos DIMITRIOU Evangelos TS1AKALOS
More information