Variations of Aniridia IOL Variations of Aniridia IOL
Transcription
Variations of Aniridia IOL Variations of Aniridia IOL
Variations of Aniridia IOL Summary Aniridia Implants Aniridia Rings TYPE: 50C 6 MM PUPIL INCISION: > 2 MM TYPE: 50D 4 MM PUPIL INCISION: > 3 MM TYPE: 50E 3,5 MM PUPIL INCISION: > 3,25 MM Partial Aniridia Rings TYPE: 96F APERTURE: 4 / 90° INCISION: > 3,5 MM TYPE: 96E APERTURE: 5,5 / 5 INCISION: > 3,5 MM Aniridia Implants TYPE: 30B 3 MM PUPIL INCISION: > 10 MM ØT =12,5 MM / 0° TYPE: 67B 3 MM PUPIL INCISION: > 10 MM ØT =12,5 MM / 0° TYPE: 67L 5 MM PUPIL INCISION: > 10 MM ØT =13,5 MM / 0° TYPE: 94A 6,5 MM PUPIL INCISION: > 10 MM ØT =13 MM / 0° TYPE: 68 4,5 MM PUPIL INCISION: > 10 MM ØT =12,5 MM / 0° TYPE: 67G 5 MM PUPIL INCISION: > 10 MM ØT =12,5 MM / 0° TYPE: 67F 5 MM PUPIL INCISION: > 10 MM ØT =13,5 MM / 0° TYPE: 67E 4 MM PUPIL INCISION: > 8 MM ØT =13,5 MM / 5° Partial Aniridia Implants 2 TYPE: 67 3,5 MM PUPIL INCISION: > 7 MM ØT =12,5 MM / 10° TYPE: 67D 3,5 MM PUPIL INCISION: > 7 MM ØT =13,5 MM / 5° TYPE: 67A 3,5 MM PUPIL INCISION: > 7 MM ØT =14 MM / 10° TYPE: 68C 3,5 MM PUPIL INCISION: > 8 MM ØT =14 MM / 10° TYPE: 94 4 MM PUPIL INCISION: > 8 MM ØT =13,5 MM / 10° TYPE: 94C 4 MM PUPIL INCISION: > 8 MM ØT =13,5 MM / 10° TYPE: 67S 5 MM PUPIL INCISION: > 8 MM ØT =13,5 MM / 10° TYPE: 67C 5 MM PUPIL INCISION: > 8 MM ØT =13,5 MM / 10° Irismatch® Implants Allgemeine Information Die Morcher Irismatch-IOL ist ein Aniridie-Implantat aus PMMA, bestehend aus einer 3,0 mm-Optik und einem farbigen Diaphragma mit Iris-Zeichnung. General Information The Morcher Irismatch IOL is an Aniridia Implant made of PMMA composed of a central 3.0 mm optic and a colored diaphragm with an iris pattern. Auswahl der Irisfarbe: Bestellungen: Mit Hilfe von Farbmustern (Augenimplantate im künstlichen Augenmodell), wird die passende Irisfarbe mit dem Patienten abgestimmt. Die Irismatch-IOL wird nur auf Bestellung gefertigt. Ihre Bestellung sollte folgende Informationen enthalten: Die 45 zur Auswahl stehenden Irisfarben befinden sich in einem Musterkoffer, der bei Ihrem Morcher Händler angefordert werden kann. - Farbnummer aus dem Musterkoffer (z. B. E010) Bitte beachten: Kleine Farbdifferenz zwischen Irismatch-Implantat und den Patienten Augen können auftreten. Selecting the color: The iris color is selected from the color samples provided (IrisMatch colors in the articifical eye model) by holding them close to the patient´s eye. - Bestellnummer (Typ 30B) - Dioptrie (z.B. +22.0D) - Beispiel: Typ 30B +22.0D E010 How to order: Each Irismatch Implant is custom-made. Therefore, the following data must accompany your order: A complete set of all color match irises currently available is provided in a sample case thet you can obtain from your distributor. - Selected color code (e.g. E010) Please note: Slight differences in color between the Irismatch Implant and the patient´s eye may occur. - Diopter (e.g. +22.0D) - Reference # of the Model (Type 30B) - Example: Typ 30B +22.0D E010 Type 30B (showing color code E010) Irismatch IOL Type 30B Design: Total Diameter: Diaphragm: Diopter range: Incision: Optic: Estimated A-Constant AB*1: Estimated A-Constant OB*2: Estimated Standard Power: Anterior Chamber Depth AB*1: Anterior Chamber DepthOB*2: Irismatch 12.5 mm 3.0 - 10.0 mm -10 up to +45Dpt 10.0 mm 3.0 mm (biconvex) 118.1 118.7 22.0 D 5.02 mm 5.37mm Patent pending, Patent No WO0166040 * 1 Acoustic biometry * 2 Optical biometry 3 Aniridia Rings Jeweils zwei dieser Ringe werden in den Kapselsack implantiert und übereinandergedreht, so dass sich eine geschlossene Blende bildet. Nach der Ringimplantation wird die IOL eingesetzt. Der Kapselsack muss dabei intakt sein! Die Verwendung von ausreichend Visco erleichtert die Implantation. Die Pupillen- und Inzisionsgröße ist je nach Typ individuell. In each case two of these aniridia rings are implanted in the capsular bag and dialled against one another to form a closed diaphragm. After the ring implantation the IOL is implanted. The capsular bag has to be intact! The use of sufficient visco makes the implantation easier.The size of the pupil and the incision depend on the design. Vorteile: - Kleine Inzision - Zusätzliche Stabilisierung des Kapselsacks - Gute Zentrierung Advantages: - Small incisions - Additional stabilization of the capsular bag - Well centered Type 50C Design: Total Diameter: Diaphragm: Pupil: Incision: Rasch/Rosenthal 10.0 mm 7 x (1.5 x 2 mm) at 46.5° 6 mm >2 mm Kapselspannring mit Irisblende, hauptsächlich verwendete Ausführung Capsular Tension Ring with iris diaphragm, most frequently used version Type 50D Design: Total Diameter: Diaphragm: Pupil: Incision: Rasch/Rosenthal/Zirm 10.0 mm 7 x (1.5 x 3 mm) at 46.5° 4 mm >3 mm Kapselspannring mit Irisblende, mit 4 mm großer Pupille Capsular Tension Ring with iris diaphragm, with a 4 mm pupil 4 *1 Acoustic biometry *2 Optical biometry Aniridia Rings Type 50E Design: Total Diameter: Diaphragm: Pupil: Incision: Rasch/Rosenthal/Zirm 10.0 mm 7 x (1.5 x 3.25 mm) at 46.5° 3.5 mm >3.25 mm Kapselspannring mit Irisblende, mit 3,5 mm großer Pupille Capsular Tension Ring with iris diaphragm, with a 3.5 mm pupil Partial Aniridia Rings Type 96F Design: Total Diameter: Diaphragm: Incision: Annen 11.0 mm 1x (3.5 mm) at 90° >3.5 mm Kapselspannring mit Kolobomblende Capsular Tension Ring with coloboma diaphragm Kapselspannringe mit Kolobomblende, um ein vorhandenes Kolobom, nicht größer als 3 Stunden, abzublenden. Bei einem Kolobom von 3 bis 6 Stunden können 2 Ringe implantiert werden Capsular tension rings with a diaphragm to dim a coloboma in the eye not larger than 3 hours Is the coloboma 3 to 6 hours 2 rings can be implanted Type 96E Design: Total Diameter: Diaphragm: Incision: Annen/Climenhaga 11.0 mm 1 x (2.75 x 5.50 mm) >3.5 mm Kapselspannring mit Kolobomblende Capsular Tension Ring with coloboma diaphragm *1 Acoustic biometry *2 Optical biometry 5 Aniridia Implants Retropupillare IOL mit Irisblende für idiopathische und traumatische Aniridie. Posterior Chamber IOL with iris diaphragm for idiopathic and traumatic anridia. Type 67G Design: Total Diameter: Diaphragm: Diopter range: Incision: Optic: Estimated A-Constant AB*1: Estimated A-Constant OB*2: Estimated Standard Power: Anterior Chamber Depth AB*1: Anterior Chamber DepthOB*2: Sundmacher 12.5 3.0 - 10.0 mm 10 - 30 dpt. in 0.5 increments, other dpt. on request >10.0 mm 5.0 mm (biconvex) 118.1 118.7 22.0 D 5.02 mm 5.37mm Meist verkauftes Aniridie-Implantat, auch ohne Optik lieferbar Most frequently used aniridia implant, also available without an optic Type 67L Design: Total Diameter: Diaphragm: Diopter range: Sundmacher/Öhrström 13.5 5.0 - 10.0 mm 10 - 30 dpt. in 0.5 increments, Incision: Optic: Estimated A-Constant AB*1: Estimated A-Constant OB*2: Estimated Standard Power: Anterior Chamber Depth AB*1: Anterior Chamber DepthOB*2: without an optic >10.0 mm 5.0 mm (biconvex) 118.1 118.7 22.0 D 5.02 mm 5.37mm other dpt. on request, also available Sonder-Aniridie-IOL mit Öffnung in der Blende (1.5 bis 3.0 mm) zur Injektion von Glaskörperersatz Special IOL with an opening in the diaphragm (1.5 to 3.0 mm) for the injection of vitreous body substitution Type 94A Design: Total Diameter: Diaphragm: Diopter range: Incision: Optic: Sonder-Aniridie-IOL ohne optische Wirkung, nur als Blende Special IOL without optical function, only as diaphragm 6 *1 Acoustic biometry *2 Optical biometry Sundmacher/Öhrström 13.0 6.5 - 10.0 mm NONE (only available without an optic) >10.0 mm 6.5 mm Aniridia Implants Type 67B Design: Total Diameter: Diaphragm: Diopter range: Incision: Optic: Estimated A-Constant AB*1: Estimated A-Constant OB*2: Estimated Standard Power: Anterior Chamber Depth AB*1: Anterior Chamber DepthOB*2: Sundmacher 12.5 3.0 - 10.0 mm 10 - 30 dpt. in 0.5 increments, other dpt. on request >10.0 mm 3.0 mm (biconvex) 118.1 118.7 22.0 D 5.02 mm 5.37mm Standard-IOL mit 3.0 mm Optik Standard IOL with a 3.0 mm optic Type 68 Design: Total Diameter: Diaphragm: Diopter range: Incision: Optic: Estimated A-Constant AB*1: Estimated A-Constant OB*2: Estimated Standard Power: Anterior Chamber Depth AB*1: Anterior Chamber DepthOB*2: Sundmacher 12.5 4.5 - 10.0 mm 10 - 30 dpt. in 0.5 increments, other dpt. on request >10.0 mm 4.5 mm (biconvex) 118.1 118.7 22.0 D 5.02 mm 5.37mm Standard-IOL mit 4.5 mm Optik Standard IOL with a 4.5 mm optic Type 67F Design: Total Diameter: Diaphragm: Diopter range: Incision: Optic: Estimated A-Constant AB*1: Estimated A-Constant OB*2: Estimated Standard Power: Anterior Chamber Depth AB*1: Anterior Chamber DepthOB*2: Sundmacher 13.5 mm 5.0 - 10.0 mm 10 - 30 dpt. in 0.5 increments, other dpt. on request, also available without an optic >10.0 mm 5.0 mm (biconvex) 118.1 118.7 22.0 D 5.02 mm 5.37mm Standard-IOL mit 5.0 mm Optik und vergrößertem Gesamtdurchmesser der Haptik (für myope Augen) Standard IOL with a 5.0 mm optic and larger sized diameter of the haptics (for myopic eyes) *1 Acoustic biometry *2 Optical biometry 7 Partial Aniridia Implants Implantate, die aufgrund der Art und Größe der partiellen Aniridie individuell vom Ophthalmologen ausgewählt werden müssen The ophthalmologist must choose each implant individually according to the state and size of the partial aniridia. Type 67 Design: Total Diameter: Diaphragm: Diopter range: Incision: Optic: Estimated A-Constant AB*1: Estimated A-Constant OB*2: Estimated Standard Power: Anterior Chamber Depth AB*1: Anterior Chamber DepthOB*2: Sundmacher/Neuhann 12.5 mm 3.5 - 7/10.0 mm 10 - 30 dpt. in 0.5 increments, other dpt. on request,also available without an optic >7.0 mm 3.5 mm (biconvex) 118.1 118.7 22.0 D 5.02 mm 5.37mm Sonder-IOL zur Abdeckung einer partiellen Aniridie mit 3.5 mm Optik Special IOL with a 3.5 mm optic to cover a partial aniridia Type 67D Design: Total Diameter: Diaphragm: Diopter range: Incision: Optic: Estimated A-Constant AB*1: Estimated A-Constant OB*2: Estimated Standard Power: Anterior Chamber Depth AB*1: Anterior Chamber DepthOB*2: Masket 13.5 mm 3.5 - 7/10.0 mm 10 - 30 dpt. in 0.5 increments, other dpt. on request >7.0 mm 3.5 mm (biconvex) 119.0 119.6 22.0 D 5.55 mm 5.90mm Sonder-IOL zur Abdeckung einer partiellen Aniridie mit 3.5 mm Optik und der Option zur Sklerafixation Special IOL with a 3.5 mm optic and the option for sclerafixation to cover a partial aniridia Type 67A Design: Total Diameter: Diaphragm: Diopter range: Incision: Optic: Estimated A-Constant AB*1: Estimated A-Constant OB*2: Estimated Standard Power: Anterior Chamber Depth AB*1: Anterior Chamber DepthOB*2: Sundmacher/Neuhann 14.0 mm 3.5 - 7/10.0 mm 10 - 30 dpt. in 0.5 increments, other dpt. on request, also available without an optic >7.0 mm 3.5 mm (biconvex) 118.1 118.7 22.0 D 5.02 mm 5.37mm Sonder-IOL zur Abdeckung einer partiellen Aniridie mit 3.5 mm Optik und großer Haptik (für myope Augen) Special IOL with a 3.5 mm optic and larger sized haptic ( for myopic eyes) to cover a partial aniridia 8 *1 Acoustic biometry *2 Optical biometry Partial Aniridia Implants Type 68C Design: Total Diameter: Diaphragm: Diopter range: Incision: Optic: Estimated A-Constant AB*1: Estimated A-Constant OB*2: Estimated Standard Power: Anterior Chamber Depth AB*1: Anterior Chamber DepthOB*2: Sundmacher/Rosenthal 14.0 mm 3.5 - 7/10.0 mm 10 - 30 dpt. in 0.5 increments, other dpt. on request >7.0 mm 3.5 mm (biconvex) 118.1 118.7 22.0 D 5.02 mm 5.37mm Sonder-IOL zur Abdeckung einer partiellen Aniridie mit 3.5 mm Optik und Option zur Sklerafixation Special IOL with a 3.5 mm optic and the option for scleralfixation to cover a partial aniridia Type 67E Design: Total Diameter: Diaphragm: Diopter range: Incision: Optic: Estimated A-Constant AB*1: Estimated A-Constant OB*2: Estimated Standard Power: Anterior Chamber Depth AB*1: Anterior Chamber DepthOB*2: Masket 13.5 mm 4.0- 8.0 mm 10 - 30 dpt. in 0.5 increments, other dpt. on request >8.0 mm 4.0 mm (biconvex) 119.0 119.6 22.0 D 5.55 mm 5.90mm Sonder-IOL mit einem Blendendurchmesser von 8 mm (für Patienten, bei denen noch ein Irissaum vorhanden ist) und der Option zur Sklerafixation Special IOL with an 8 mm diaphragm for patients with a partial iris hem left and the option for sclerafixation Type 94 Design: Total Diameter: Diaphragm: Diopter range: Incision: Optic: Estimated A-Constant AB*1: Estimated A-Constant OB*2: Estimated Standard Power: Anterior Chamber Depth AB*1: Anterior Chamber DepthOB*2: Sundmacher/Welt 13.5 mm 4.0 - 8.0 mm 10 - 30 dpt. in 0.5 increments, other dpt. on request, also available without an optic >8.0 mm 4.0 mm (biconvex) 118.1 118.7 22.0 D 5.02 mm 5.37mm Sonder-IOL mit einem Blendendurchmesser von 8 mm für Partienten, bei denen noch ein Irissaum vorhanden ist Special IOL with an 8 mm diaphragm for partients with a partial iris hem left *1 Acoustic biometry *2 Optical biometry 9 Partial Aniridia Implants Type 94C Design: Total Diameter: Diaphragm: Diopter range: Incision: Optic: Estimated A-Constant AB*1: Estimated A-Constant OB*2: Estimated Standard Power: Anterior Chamber Depth AB*1: Anterior Chamber DepthOB*2: Nowak 13.5 4.0 - 8.0 mm 10 - 30 dpt. in 0.5 increments, other dpt. on request >8 mm 4.0 mm biconvex 118.1 118.7 22.0 D 5.02 mm 5.37mm Sonder-IOL mit einem Blendendurchmesser von 8 mm (für Patienten, bei denen noch ein Irissaum vorhanden ist) und der Option zur Sklerafixation Special IOL with an 8 mm diaphragm for patients with a partial iris hem left and the option for sclerafixation Type 67S Design: Total Diameter: Diaphragm: Diopter range: Incision: Optic: Estimated A-Constant AB*1: Estimated A-Constant OB*2: Estimated Standard Power: Anterior Chamber Depth AB*1: Anterior Chamber DepthOB*2: Welt/Sundmacher 13.5 5.0-8.0 mm 10 - 30 dpt. in 0.5 increments, other dpt. on request, also available without an optic >8 mm 5.0 mm biconvex 118.1 118.7 22.0 D 5.02 mm 5.37mm Sonder-IOL mit einem Blendendurchmesser von 8 mm für Partienten, bei denen noch ein Irissaum vorhanden ist Special IOL with an 8 mm diaphragm for partients with a partial iris hem left Type 67C Design: Total Diameter: Diaphragm: Diopter range: Incision: Optic: Estimated A-Constant AB*1: Estimated A-Constant OB*2: Estimated Standard Power: Anterior Chamber Depth AB*1: Anterior Chamber DepthOB*2: 10 *1 Acoustic biometry *2 Optical biometry Sundmacher/Jähne 13.5 5.0-8.0 mm 10 - 30 dpt. in 0.5 increments, other dpt. on request 8 mm 5.0 mm biconvex 118.1 118.7 22.0 D 5.02 mm 5.37mm Allgemeine Informationen Im Jahre 1991 wurde in Zusammenarbeit mit Herrn Prof. Sundmacher von der Universität Düsseldorf eine spezielle IOL mit integriertem Iris-Diaphragma zur intraokularen Korrektur von Aniridie entwickelt. Bei Aniridie fehlt die Iris ganz oder teilweise dies kann angeboren oder verletzungsbedingt sein; das Licht fällt ungehindert auf die Netzhaut und blendet den Patienten. Die Verwendung dieser Implantate soll die Blendung beseitigen. Unsere Aniridie-Implantate sind seit 1991 klinisch erprobt und 1994 CE-zertifiziert worden. General Infos In 1991, in cooperation with Prof. Sundmacher of the University of Düsseldorf, MORCHER® developed a special IOL with an integrated iris diaphragm to correct congenital and traumatic forms of aniridia. Aniridia is a condition where the iris or part of the iris is missing and thus light falls on the retina unimpeded, blinding the individual. Aniridia can be congenital or result from injury. The implantation of an aniridia implant is to eliminate the glare caused by aniridia. Our aniridia implants have been clinically tested since 1991 and were CE certified in the course of a product certification in 1994. Vorteile - Durch die Implantation dieser Implantate gelangt wieder eine kontrollierte Lichtmenge in das Auge und gleichzeitig wird der Graue Star behandelt. - Produktvielfalt - Sonderanfertigungen auf Kundenwunsch - Individueller Dioptriebereich - Seit über 10 Jahren bewährt Advantages - By the implantation of aniridia implants a controlled amount of light enters the eye and, at the same time, the cataract is treated - Product diversity - Custom-made designs - Individual dioptre range - Approved for more than 10 years Wichtiger Hinweis Bei der Handhabung der Implantate ist zu berücksichtigen, dass schwarzes PMMA bruchanfälliger ist als transparentes, vorbehandeltes PMMA, speziell beim Übergang von der Haptik zur Blende, daher ist besondere Sorgfalt beim Handling mit der Pinzette anzuwenden. Please note When handling aniridia implants please note that black PMMA is more brittle than the transparent, pre-treated PMMA material. The crossing of the haptic to the diaphragm, which is especially brittle, is to be seized with forceps with the utmost care. A-Konstanten Alle angegebenen A-Konstanten sind Mittelwerte. Wir empfehlen eigene Werte zu ermitteln, die gegebenfalls von unseren abweichen können. A-Constants All numbers listed within the catalog are presented as guidelines only. We recommend you develop your own A-constants based on your experience. 11 ® MORCHER IOL . Version: 2009-08-01 Tsa Morcher GmbH Kapuzinerweg 12 D-70374 Stuttgart Tel.: +49 (0)7 11/9 53 20-0 Fax: +49 (0)7 11/9 53 20-80 e-mail: [email protected] www.morcher.com
Similar documents
catalog aniridia iol
Alle angegebenen A-Konstanten sind empfohlene Mittelwerte. Bitte ermitteln Sie eigene Werte, die eventuell von unseren abweichen können.
More information