Braun Infrared ear thermometer IRT4520/4020
Transcription
Braun Infrared ear thermometer IRT4520/4020
English 4 15 25 This product is manufactured by Kaz Europe SA under a license to the ‘Braun’ trademark. ‘Braun’ is a registered trademark of Braun GmbH, Kronberg, Germany. ThermoScan is a registered trademark of Kaz Europe SA Kaz Europe SA Place Chauderon 18 CH-1003 Lausanne Switzerland 0297 ©2011, Kaz Europe SA ® www.kaz-europe.com Designed in Germany Made in Mexico US Patent Nos. 6,626,835; 6,203,194; 6,149,298; 6,022,140; 6,694,174; 7,014,358; D460,006 TW Patent Nos. NI-159809; NI-112501; 393570; 410272; NI-147458; ND-084456 KR Patent Nos. 0628283; 100507716; 0626189; 10-0883150 JP Patent Nos. 4619499; 4546650; 4052945; 4668250; 1144805 CN Patent Nos. 00124323.3; 99803219.8; 00804341.8; 02805125.4; 01337258 HK Patent Nos. 1024053; 1042550; 1062043 AU Patent Nos. 2002250974 IRT4520 / IRT4020 31IM4520198 12AUG13 2 3 Braun Thermoscan IRT 4000 series Indications for use: Instrument IRT 4000 series The Braun ThermoScan IRT 4000 series infrared ear thermometers are indicated for the intermittent measurement and monitoring of human body temperature by consumers in a home use environment. ThermoScan ThermoScan IRT 4520 IRT 4020 Temperature measurement within seconds ■ ■ Temperature range °C 34-42.2 34-42.2 Temperature range °F 93.2-108.0 93.2-108.0 ExacTemp technology ■ ■ Feedback system ■ ■ Ready beep ■ ■ Small, soft tip ■ Flexible tip The physical size of the instrument shall be approx. 152mm, by 44mm, by 33mm. The weight shall be approx. 100g, without the batteries. Cap The physical size of the cap shall be approx. 35mm, by 35mm, by 20mm. The weight shall be approx. 15g. The cap shall protect the probe against pollution. It shall not cover the LC display. Product specifications Product Physical size and weight ■ Instrument cover The physical size of the instrument cover shall be approx. 160mm by 75mm by 38mm. The weight shall be approx. 30g. Range definition/ Feature matrix IRT 4020 IRT 4520 Feature (Mass) (6 023) (Pharmacy) (6 022) Sensor system Unique ExacTemp sensor technology ■ Site offsets Ear mode ■ Patient temp. range 34°C..42.2°C 10°C..40°C Memory storage capacity 8 1 Ambient temp. range Auto-off after 60 sec. 60 sec. Operating lifetime 5 years/ 10 000 readings Easy-to-read LCD display ■ ■ Battery type 2* AA (LR6) Lens filter detector ■ ■ Lens filter ejector ■ ■ Battery lifetime at normal ambient temp. 1000 readings and 5 years shelf life Protective case with lens filter storage ■ Probe protection and thermometer storage Simple cap for probe IRT instrument cover to hold protection only thermometer and LF 20 ■ Battery charging N/A Charging time N/A Protective cap Batteries included ■ ■ 21 lens filter included ■ ■ Colour Blue Green Model No: IRT 4020, IRT 4520 Accessories: Protective cap (LF20) Manufactured by: Key Tronic Corporation. Magneto # 7824, Parque Ind. Gema. Plant 1, Juarez, Chihuahus, Mexico Manufactured for: Kaz Europe S.A., Place Chauderon 18, CH-1003 Lausanne, Switzerland 4 5 English The Braun ThermoScan thermometer has been carefully developed for accurate, safe and fast temperature measurements in the ear. The shape of the thermometer prevents it from being inserted too far into the ear canal to hurt the eardrum. However, as with any thermometer, proper technique is critical to obtain accurate temperatures. Therefore, read the use instructions carefully and thoroughly. Important • The operating ambient temperature range for this thermometer is 10 – 40 °C (50 – 104 °F). • Do not expose the thermometer to temperature extremes (below – 20 °C / –4 °F or over 50 °C / 122 °F) nor excessive humidity (> 95 % RH). • This thermometer must only be used with genuine Braun ThermoScan lens filters (LF 40). Never use this thermometer without a new, clean lens filter attached. • Keep lens filters out of reach of children. • This thermometer is intended for household use only. • Use of this thermometer is not intended as a substitute for consultation with your physician. How does Braun ThermoScan work? Body temperature Normal body temperature is a range. The following table shows that this normal range also varies by site. Therefore, readings from different sites should not be directly compared. Normal ranges by site: Axillary: 34.7 – 37.3 °C 94.5 – 99.1 °F Oral: 35.5 – 37.5 °C 95.9 – 99.5 °F Rectal: 36.6 – 38.0 °C 97.9 – 100.4 °F ThermoScan: 35.8 – 38.0 °C 96.4 – 100.4 °F • As well, a person’s normal temperature range tends to decrease with age. The following table shows normal ThermoScan ranges by age. Normal ThermoScan ranges by age: 0 – 2 years 36.4 – 38.0 °C 97.5 – 100.4 °F 3 – 10 years 36.1 – 37.8 °C 97.0 – 100.0 °F 11 – 65 years 35.9 – 37.6 °C 96.6 – 99.7 °F > 65 years 35.8 – 37.5 °C 96.4 – 99.5 °F Braun ThermoScan measures the infrared heat generated by the eardrum and surrounding tissues. To avoid gross temperature differences, the sensor itself is brought to a temperature close to that of the human body. When the Braun ThermoScan is placed in the ear, it continuously monitors the infrared radiation. The measurement will be finished and the result is displayed, when an accurate reading can be assured. However, the range of normal also varies from person to person and fluctuates throughout the day. It is therefore important to determine your normal temperature range. This is easily done using Braun ThermoScan. Practice taking temperatures on yourself and healthy family members to determine their normal temperature ranges. Why measure in the ear? Note: When consulting your physician, communicate that the ThermoScan temperature is a temperature measured in the ear and if possible, note the individual’s normal ThermoScan temperature range as additional reference. The goal of thermometry is to measure core body temperature which is the temperature of the vital organs. Ear temperatures accurately reflect core body temperature, since the eardrum shares blood supply with the temperature control center in the brain, the hypothalamus. Therefore, changes in body temperature are reflected sooner and more accurately in the ear than at other sites. • Axillary temperatures only measure skin temperature and therefore, are not a reliable indicator of core body temperature. • Oral temperatures are influenced by drinking, eating and breathing. • Rectal temperatures lag behind changes in core body temperature and there is a risk of cross-contamination. 6 7 1. Lens filter 2. Probe 3. Lens filter detector 4. Lens filter ejector 5. Display 6. «I/O» button (On/memory function – IRT 4520 only) 7. «ExacTemp» light 8. «start» button 9. Battery door 10. Protective cover (IRT 4520) 11. Cap (IRT 4020) How to use your Braun ThermoScan? 1. To achieve accurate readings, make sure a new, clean lens filter (1) is in place before each measurement. start IRT 4020 IRT 4520 2. IRT 4020: Push the «start» button (8). IRT 4520: Push the «I/O» button (6). mp Te ac During an internal self-check, the display shows all segments. Then the last temperature taken will be displayed together with «MEM». E xa cT Wait for the ready signal beep and the ready symbol in the display. en 3. Fit the probe snuggly into the ear canal, then push the «start» button (8). n ca oS erm Th 8 If the probe has been fitted securely into the ear canal during the complete measuring process, a long beep will signal the end of the measuring process. You can be assured to have taken an accurate temperature reading. The result is shown on the display (5). If you take the temperature of another person, the «ExacTemp» light (7) will be of help. It flashes during the measuring process as long as the probe is securely positioned, and lights up continuously when an accurate reading has been taken. 4. If the probe has not been constantly placed in a stable position in the ear canal, a sequence of short beeps will sound, the «ExacTemp» light will go out and the display will show an error message («POS» = position error). 5. For the next measurement, eject the used lens filter (push ejector (4)) and put on a new, clean lens filter. IRT 4020: Clear the display by pushing the «start» button once. IRT 4520: Clear the display by pushing the «I/O» button once. Wait for the ready signal. Fit the probe snuggly into the ear canal, then push the «start» button. The Braun ThermoScan ear thermometer turns off automatically after 60 seconds of inactivity. The IRT 4520 can also be turned off by pressing the «I/O» button for at least three seconds. The display will shortly flash «OFF» and after releasing the button it will go blank. Temperature taking hints • Always replace disposable lens filters to maintain accuracy and hygiene. • The right ear reading may differ from the reading taken at the left ear. Therefore, always take the temperature in the same ear. • The ear must be free from obstructions or excess earwax build-up to take an accurate reading. • External factors may influence ear temperatures, including when an individual has: – been lying on one ear or the other – had their ears covered – been exposed to very hot or very cold temperatures, or – been recently swimming or bathing. 9 Exac T Product description (see page 3) en In these cases, remove the individual from the situation and wait 20 minutes prior to taking a temperature. • Use the untreated ear if prescription ear drops or other ear medications have been placed in the ear canal. Care and cleaning Memory mode If the thermometer is ever accidentally used without a lens filter, clean the probe tip as follows: Very gently wipe the surface with a cotton swab or soft cloth moistened with alcohol. After the alcohol has completely dried out, you can put a new lens filter on and measure. If the probe tip is damaged, please contact your authorized local service centre. The last temperature taken is stored in its memory and will be automatically displayed when it is turned on again. The display will show «MEM». IRT 4520: This model stores the last 8 temperature readings. To display the stored readings, the thermometer must be turned on. Then press the «I/O» button for at least 1 second. The display shows the memory number (e. g. MEM 1), and when releasing the «I/O» button, the stored temperature for that memory number is displayed, together with «MEM». If «I/O» button is pressed too long, the thermometer will be switched off. Each further pressing of the «I/O» button displays the remaining memory numbers (up to MEM 8). MEM 1 is the latest reading, MEM 8 would be the oldest. The memory mode is left automatically after displaying the oldest reading, or after pressing the «I/O» button for at least 1 second. Changing the temperature scale The probe tip is the most delicate part of the thermometer. It has to be clean and intact to ensure accurate readings. Use a soft, dry cloth to clean the thermometer display and exterior. Do not use abrasive cleaners. Never submerge this thermometer in water or any other liquid. Store thermometer and lens filters in a dry location free from dust and contamination and away from direct sunlight. Additional lens filters (LF 40) are available at most stores carrying Braun ThermoScan. For more information, please contact your authorized local service centre. Hong Kong service center contact number: +852 2686 3319 Taiwan service center contact number: +886 0800278789 China service center contact number: +86 021-61280577 Singapore service center contact number: +65 65522422 Your Braun ThermoScan is shipped with the Celsius (°C) temperature scale activated. If you wish to switch to Fahrenheit (°F) and/or back from Fahrenheit to Celsius, proceed as follows: (1)Make sure the thermometer is turned off. (2)Press and hold down the «start» button (IRT 4020) or the «I/O» button (IRT 4520). After about 3 seconds the display will show this sequence: «°C» / «SET» / «°F» / «SET» ... (3)Release the «start» button / «I/O» button when the desired temperature scale is shown. There will be a short beep to confirm the new setting, then the thermometer is turned off automatically. 10 11 Trouble-shooting Trouble-shooting Error message Situation Solution No lens filter is attached. Attach new, clean lens filter. The thermometer cannot identify a secure position of the probe. An accurate measurement was not possible. IRT 4020: Clear the display by pushing the «start» button once. IRT 4520: Clear the display by pushing the «I/O» button once. POS = position error Take care that the positioning of the probe is correct and remains stable. Ambient temperature is not within the allowed operating range (10 – 40 °C or 50 – 104 °F). Allow the thermometer to remain in a room for 30 minutes where the temperature is between 10 and 40 °C or 50 and 104 °F. Temperature taken is not within typical human temperature range (34 – 42.2 °C or 93.2 – 108 °F). HI = too high Make sure a new, clean lens filter is attached and thermometer is properly inserted. Then, take a new temperature. LO = too low System error – self-check display flashes continuously and will not be followed by the ready beep and the ready symbol. Wait 1 minute until the thermometer turns off automatically, then turn on again. If error persists, ... reset the thermometer by removing the batteries and putting them back in. If error still persists, Please contact your authorized service centre. Hong Kong service center contact number: +852 2686 3319 Taiwan service center contact number: +886 0800278789 China service center contact number: +86 021-61280577 Singapore service center contact number: +65 65522422 12 Situation Solution Battery is low, but thermometer will still operate correctly. Insert new batteries. Battery is too low to take correct temperature readings. Insert new batteries. Do you have any further questions? Please contact your authorized service centre Hong Kong service center contact number: +852 2686 3319 Taiwan service center contact number: +886 0800278789 China service center contact number: +86 021-61280577 Singapore service center contact number: +65 65522422 Error message Replacing the batteries The thermometer is supplied with two 1.5 V type AA (LR 06) batteries. For best performance, we recommend Duracell alkaline batteries. Insert new batteries when the battery symbol appears on the display. Open the battery compartment. Remove the batteries and replace with new batteries, making sure the poles are in the right direction. Slide battery door back until it snaps in place. To protect the environment, dispose of empty batteries at your retail store or at appropriate collection sites according to national or local regulations. Calibration The thermometer is initially calibrated at the time of manufacture. If this thermometer is used according to the use instructions, periodic re-adjustment is not required. If at any time you question the accuracy of the temperature measurement, please contact your authorized service center. Hong Kong service center contact number: +852 2686 3319 Taiwan service center contact number: +886 0800278789 China service center contact number: +86 021-61280577 Singapore service center contact number: +65 65522422 The manufacturing date is given by the serial numbers located on the product. The first three digits represent the day of the year of manufacture. The next two digits give the last two numbers of the year of manufacture. An example: SN: 25008knnnnn-this product has been manufactured on the 250th day of the year 2008. 13 2 1 Product specifications (see page 3) Model: Displayed temperature range: Operating ambient temperature range: Display resolution: Accuracy for displayed temperature range: IRT4520/4020 34 – 42.2 °C (93.2 – 108 °F) 10 – 40 °C (50 – 104 °F) 0.1 °C or °F ± 0.2 °C (35.5 – 42 °C) (95.9 – 107.6 °F) ± 0.3 °C (outside this temperature range) ± 0.14 °C (± 0.26 °F) 2 years / 1000 measurements Clinical repeatability: Battery life: Type BF equipment See instruction of use 40°C 10°C Operating temperature Subject to change without notice. This appliance conforms to the following standards: Standard Reference Edition Title: EN 12470-3 2000 linical thermometers - Part 3: Performance of compact C electrical thermometers (non-predictive and predictive) with maximum device EN 60601-1 2006 edical electrical equipment – Part 1: General M requirements for basic safety and essential performance. EN ISO 14971 2007 edical devices – Application of risk management to M medical devices. EN ISO 10993-1 2003 iological evaluation of medical devices – Part 1: B Evaluation and Testing. EN 60601-1-2 2007 edical electrical equipment – part 1-2: General M requirements for basic safety and essential performance – Collateral standard: electromagnetic compatibility – Requirements and tests EN 980 2008 Symbols for use in labeling of medical devices EN 1041 2008 Information supplied by the manufacturer of medical This product conforms to the provisions of the EC directive 93/42/EEC (Medical device directive). Medical electrical equipment needs special precautions regarding EMC. For detailed description of EMC requirements please contact your authorized service centre. Hong Kong service center contact number: +852 2686 3319 Taiwan service center contact number: +886 0800278789 China service center contact number: +86 021-61280577 Singapore service center contact number: +65 65522422 Portable and mobile RF communications equipment can affect medical electrical equipment. Please do not dispose of the product in the household waste at the end of it useful life. To protect the environment, dispose of empty batteries at appropriate collection sites according to national or local regulations. 14 15 耳 耳 耳 盖 耳 start IRT 4020 IRT 4520 E xa cT mp Te ac n ca oS erm Th 16 17 en Exac T en 耳 耳 耳 18 19 耳 耳 沒有套上耳 耳 耳 耳 耳 耳 耳 耳 耳 耳 耳 耳 耳 耳 耳 耳 耳 20 21 +86 021-61280577 2 耳 1 耳 SN SN: 25008knnnnn – 2008 22 250 23 百靈耳溫槍 Braun ThermoScan infrared ear thermometers 型號: IRT 4020, IRT 4520 使用前請務必詳閱原廠之使用說明書並遵照指示使用。 衛署醫器輸字第 022485號 產品敘述及用途: 百靈耳溫槍是藉由轉換器, 藉著電子訊號放大, 調整及顯示的方法, 來測量患者體溫的器材。 轉換器是置於可分離的探針中。 產品規格 耳 產品 ThermoScan ThermoScan 型號 IRT 4520 IRT 4020 幾秒內可測量溫度 ■ 恆茂國際貿易(上海)有限公司 上海市宜山路2016號合川大廈7樓A室 郵編: 201103 顧客咨詢熱線:+86 021-61280577 ■ 溫度顯示範圍°C 34-42.2 34-42.2 溫度顯示範圍°F 93.2-108.0 93.2-108.0 正確溫度技術 ■ ■ 反饋系統 ■ ■ 短嗶聲 ■ ■ 微小、柔軟的尖端 ■ ■ 有彈性的尖端 ■ ■ 儲存容量 8 1 使用後自動斷電 60秒 60秒 液晶螢幕 ■ ■ 耳套偵測器 ■ ■ 耳套彈出器 ■ ■ 包裝外盒含耳套 ■ ■ 保護套 含電池 ■ ■ 含耳套 顏色 ■ 藍色 ■ 綠色 型號: IRT 4020, IRT 4520 附件: 耳套(LF20) 24 25 26 27 套彈出裝置 蓋 start IRT 4020 IRT 4520 E xa cT mp Te ac n ca oS erm Th 28 29 en Exac T en 30 31 32 33 +886 0800-278-789 +852 2686 3319 2 1 台灣維修中心 泰豐生技股份有限公司 新北市三重區重新路五段609 巷 10 號4F 電話 : +886 0800-278-789 SN后的第一、二、三碼表 示該年份的製造日,第四、五碼表示製造年份。 SN: 25008knnnnn – 2008 34 250 香港維修中心 利豐亞洲(香港)有限公司- 醫療保健組 沙田小瀝源安平街2號利豐中心14字樓 電話 : +852 2686 3319 製造廠名稱/地址: Manufactured by: Key Tronic Corporation (Magneto # 7824, Parque Ind. Gema, Plant 1, Juarez, Chihuahua, Mexico) for: Kaz Europe S.A. (Place Chauderon 18, CH-1003 Lausanne, Switzerland) 藥商名稱: 香港商卡舒遠東有限公司台灣分公司 藥商地址: 台北市北投區北投路二段13號4樓之1 35 36