Multi-layer Insulation Blanket for use in Roofs
Massive Thermal Insulation in a Thin, Flexible, Multi-layer Membrane
HIGHEST PERFORMING MULTI-FOIL ON
FULLY INDEPENDENTLY
THE MARKET TESTED
FULLY
CERTIFIED
KEEPS YOUR
HOUSE
COOLER IN SUMMER
CAN MEET BUILDING REGULATIONS (ALWAYS
MEETS
REGULATIONS
CHECK
WITHBUILDING
LOCAL BUILDING
CONTROL)
IDEAL
FOR LOFT
MEETS
0.16CONVERSIONS
U-VALUE!
FAST
FAST AND
AND SIMPLE
SIMPLE INSTALLATION
INSTALLATION
LIGHTWEIGHT,
THIN
AND
FLEXIBLE
LIGHTWEIGHT
AND
FLEXIBLE
KEEPS
KEEPS YOUR
YOUR HOUSE
HOUSE WARMER
WARMER IN
IN WINTER
WINTER
KEEPS
KEEPS YOUR
YOUR HOUSE
HOUSE COOLER
COOLER IN
IN SUMMER
SUMMER
EFFECTIVE
SOLAR
OVER
HEATING
KEEPS YOUR
HOUSE
COOLER
IN BARRIER
SUMMER
LABC 362-3-7138
CIM 122/R3
167855
BDA Agrément Nr.
BPD 08-275, BPD 08-276, BPD 08-277
Contents
In situ testing approval
CIM 122/R3
LABC 362-3-7138
P3................................................................................Testing Information
P4..............................................Over/under rafter application
P5.....................Exposed rafter close boarding detail
P6.......................Recessed and fixed between rafters
P7.........................................................................................................Purlin detail
P8..............................................................................................Rooflight detail
P9...........................................Eves/valley/downlighter detail
Hot box testing approval
BDA: BPD 08-275
BDA: BPD 08-276
BDA: BPD 08-277
P10.............................................................................Testing Information
P11..........................Two layer application 0.19 U-Value
P12..................SuperQuilt with additional insulation
P13..................SuperQuilt with additional insulation
P14....................................................................Close boarding detail
P15.....................................................................................................Purlin detail
P16.......................................Eves/valley/downlighter detail
page 2
In situ testing approval
CIM 122/R3
LABC 362-3-7138
SuperQuilt is a very flexible, easy to fit, multilayer insulation that offers tremendous thermal
benefits.
Tests have shown that SuperQuilt provides insulation equal to 270 mm of glass wool when installed in a pitched roof situation. SuperQuilt
now has full certification with Local Authority
Building Control.
How does SuperQuilt Work?
Due to the special composition of multi-layers of
insulation SuperQuilt effectively deals with all
forms of energy transfer (i.e. conduction, convection and radiation). SuperQuilt works most effectively by reflecting infra-red radiation.
This means that not only is SuperQuilt effective in
winter, by reflecting heat back into the building and
cold out, but also in summer Super-Quilt is a very effective solar over heating barrier reducing the need
for artificial cooling systems, and preventing uncomfortable heat build up in the roof.
BRE testing
Moisture Performance
of SuperQuilt
BRE Report number
223653.1
BRE was
commissioned by
YBS Insulation to
assess the vapour
transmission of
SuperQuilt.
The vapour
permeability was
used to calculate
the vapour
resistance (Rv) of
the material.
The Rv was
measured as
390.6MNs/g.
MANUFACTURED IN UK AND MADE
TO A QUALITY SYSTEM MEETING THE
REQUIREMENTS OF BS EN ISO 9002
Accreditation & Testing
page 3
over/under rafters application
SuperQuilt is fast
and simple to install. With great
benefits, keeping
rafter depths to a
minimum, lightweight and high
insulation values.
Over Rafter Fixing Details
Under Rafter Fixing Details
SuperQuilt is rolled out over the rafters horizontally or vertically
and stapled in position. All joints are taped with YBS Foil Tape.
SuperQuilt is rolled out to the under side of the rafters horizontally
or vertically and stapled in position. All joints are taped with YBS
Foil Tape.
At the eves SuperQuilt is cut around the rafters and sealed to the
Cavity wall insulation or wall plate.
Battens are placed parallel with the rafters and fixed.
At the eves SuperQuilt is sealed to the Cavity wall insulation or wall
plate.
A breather-membrane is fitted in accordance with the manufacturers fixing details, above the battens.
Counter battens are placed parallel or perpendicular with the
rafters and fixed.
Tile battens and tiles are then fitted.
Plasterboard can then be fixed to the counter battens.
SuperQuilt Over Rafter Application
SuperQuilt Under Rafter Application
ROOF COVERING (SLATE SHOWN)
ROOF COVERING (SLATE SHOWN)
SLATE/TILING BATTEN
SLATE/TILING BATTEN
BREATHER MEMBRANE
ON TOP OF COUNTER BATTEN
ROOFING FELT
RAFTER
RAFTER
(VENTILATED AIR GAP)
25MM
COUNTER
BATTEN
MIN 25 THICK
BATTEN TO
RETAIN
INSULATION
TO TOP FACE
OF RAFTER
SuperQuilt INSULATION
ALL JOINTS YBS FOIL TAPED
SuperQuilt INSULATION
ALL JOINTS YBS FOIL TAPED
PLASTERBOARD
PLASTERBOARD
Over Rafter U-value calculation
Construction
Outside Surface Resistance
Tiles
Tile Battens
Breather Membrane
Battens
SuperQuilt
Rafters
Plasterboard
Inside Surface Resistance
Thickness
Thermal
(mm)
Conductivity
(W/mK)
10.00
25.00
25.00
25.00
150.00
12.50
0.190
-
Under Rafter U-value calculation
Thermal
Resistance
(m2K/W)
0.100
0.000
0.000
0.000
6.100
0.000
0.066
0.100
Construction
Outside Surface Resistance
Tiles
Tile Battens
Breather Membrane
Rafters
SuperQuilt
Battens
Plasterboard
Inside Surface Resistance
U-Value, Combined Method: 0.16W/m2K
(lower limit = 6.366m2K/W, upper limit = 6.366m2K/W)
Thickness
Thermal
(mm)
Conductivity
(W/mK)
10.00
25.00
150.00
25.00
25.00
12.50
0.190
-
U-Value, Combined Method: 0.16W/m2K
(lower limit = 6.366m2K/W, upper limit = 6.366m2K/W)
page 4
Thermal
Resistance
(m2K/W)
0.100
0.000
0.000
0.000
6.100
0.000
0.066
0.100
exposed rafters close boarding detail
SuperQuilt can be used over
close boarding. In situations
where exposed rafters are required or boarding for structural
support, then
SuperQuilt can be fitted above
the boarding creating cavities
with counter battens.
Fixing Details
Close boarding or plasterboard is fixed above the
rafters. Counter battens are fixed parallel with the
rafters through the boarding into the rafters with clout
nails.
SuperQuilt is rolled out onto the counter battens horizontally or vertically and stapled in position. All joints are taped with YBS Foil Tape.
At the eves SuperQuilt is cut around the rafters and sealed to the
Cavity wall insulation or wall plate to create an airtight envelope.
Battens are placed on top of the SuperQuilt, parallel with the rafters
and fixed in to the counter battens. A breather membrane is then fitted in accordance with the manufacturers fitting instructions.
Tile battens and tiles can then be fitted.
Scottish Detail
Exposed Rafters Close Boarding Detail
ROOF COVERING (SLATE SHOWN)
SLATE/TILES
SLATE/TILE BATTENS
SLATE/TILING BATTEN
BREATHER MEMBRANE
BREATHER MEMBRANE
SARKING BOARD
RAFTER
RAFTERS
MIN 25MM THICK
COUNTER BATTEN
SuperQuilt
INSULATION
JOINTS YBS FOIL TAPED
BATTENS
PLASTERBOARD
SuperQuilt
INSULATION
JOINTS YBS FOIL TAPED
25MM COUNTER
BATTENS
CLOSE BOARDING
Scottish Detail U-value calculation
Exposed Rafter Close Boarding / Plasterboard U-value calculation
Construction
Outside Surface Resistance
Tiles
Tile Battens
Breather Membrane
Counter Battens
SuperQuilt
Counter Battens
Plasterboard / Plywood
Rafters
Inside Surface Resistance
Thickness
Thermal
(mm)
Conductivity
(W/mK)
10.00
25.00
25.00
25.00
25.00
12.50
0.190
150.00
-
Construction
Thermal
Resistance
(m2K/W)
0.100
0.000
0.000
0.000
6.100
0.000
0.066
0.000
0.100
Outside Surface Resistance
Tiles/Slates
Tile/Slate Battens
Breather Membrane
Sarking Board
Rafters
SuperQuilt
Battens
Plasterboard
Inside Surface Resistance
Thickness
Thermal
(mm)
Conductivity
(W/mK)
10.00
25.00
18.00
150.00
25.00
25.00
12.50
0.190
-
U-Value, Combined Method: 0.16W/m2K
(lower limit = 6.366m2K/W, upper limit = 6.366m2K/W)
U-Value, Combined Method: 0.16W/m2K
(lower limit = 6.366m2K/W, upper limit = 6.366m2K/W)
page 5
Thermal
Resistance
(m2K/W)
0.100
0.000
0.000
0.000
0.000
6.100
0.000
0.066
0.100
recessed and fixed between rafters
SuperQuilt can be fitted
between rafters. In situations where head room
is crucial SuperQuilt is recessed in to the rafter
void to allow plasterboard to be fitted directly to the SuperQuilt
on the underside of the
rafters.
Over Rafter Fixing Details
Under Rafter Fixing Details
Where roof height is critical SuperQuilt can be recessed between
the rafters.
A. SuperQuilt is stapled to the top of the first rafter.
B.SuperQuilt is recessed into the rafter void and fixed by staples
or with battens.
C.The material is then fixed to opposed rafter as per instruction B.
D. SuperQuilt is then wrapped around the rafter and the procedure
starts again.
Once all the SuperQuilt is fitted all joints should be taped using
YBS Foil Tape.
A breather membrane is then fitted in accordance with the manufacturers fitting instructions.
Tile batten and tiles can then be fitted.
Where roof head room is essential SuperQuilt can be recessed between the rafters.
1. SuperQuilt is stapled to the underside of the first rafter.
2. SuperQuilt is recessed into the rafter void and fixed by staples
or with battens.
3. The material is then fixed to opposed rafter as per instruction 2.
4. SuperQuilt is then wrapped around the rafter and the procedure
starts again.
Once all the SuperQuilt is fitted all joints should be taped using
YBS Foil tape.
Plasterboard can then be fixed directly to the underside of the
rafters below the SuperQuilt.
SuperQuilt Over Rafter Application
SuperQuilt Under Rafter Application
ROOF COVERING (TILES SHOWN)
BREATHER MEMBRANE
ROOF COVERING (TILES SHOWN)
ROOFING FELT
ON TOP OF
RAFTERS
SLATE/TILING BATTEN
SLATE/TILING BATTEN
D
A
RAFTERS
C
B
RAFTERS
3
2
SuperQuilt
INSULATION
JOINTS YBS FOIL
TAPED
BATTEN
OR STAPLE
BATTEN
1
4
OR STAPLE
SuperQuilt
INSULATION
JOINTS YBS FOIL
TAPED
PLASTERBOARD AND FINISH
PLASTERBOARD AND FINISH
Over Rafter U-value calculation
Construction
Outside Surface Resistance
Tiles
Tile Battens
Breather Membrane
Rafters
SuperQuilt
Rafters
Plasterboard
Inside Surface Resistance
Thickness
Thermal
(mm)
Conductivity
(W/mK)
10.00
25.00
25.00
25.00
150.00
12.50
0.190
-
Under Rafter U-value calculation
Thermal
Resistance
(m2K/W)
0.100
0.000
0.000
0.000
6.100
0.000
0.066
0.100
Construction
Outside Surface Resistance
Tiles
Tile Battens
Breather Membrane
Rafters
SuperQuilt
Rafter
Plasterboard
Inside Surface Resistance
U-Value, Combined Method: 0.16W/m2K
(lower limit = 6.366m2K/W, upper limit = 6.366m2K/W)
Thickness
Thermal
(mm)
Conductivity
(W/mK)
10.00
25.00
150.00
25.00
25.00
12.50
0.190
-
U-Value, Combined Method: 0.16W/m2K
(lower limit = 6.366m2K/W, upper limit = 6.366m2K/W)
page 6
Thermal
Resistance
(m2K/W)
0.100
0.000
0.000
0.000
6.100
0.000
0.066
0.100
purlin details
SuperQuilt is the
solution to difficult details e.g.
around purlins
and other obstructions.
Between Purlins fixing details
Behind Purlins fixing details
SuperQuilt is fixed horizontally or vertically and stapled to the underside of the the rafters.
SuperQuilt is fixed horizontally or vertically and stapled to the underside of the the rafters.
At the purlins the SuperQuilt is turned up at stapled in place.
At the purlins the SuperQuilt is cut and pushed behind the purlins
then taped to the next piece at the opposed side of the purlin.
Battens are fixed through the SuperQuilt into the rafters, at the
purlins the battens are fixed into the rafters crushing the SuperQuilt
tightly against the purlins.
Battens are fixed through the SuperQuilt into the rafters.
Plasterboard can then be fixed to the battens.
Plasterboard can then be fixed to the battens.
Between Purlins
Around Purlins
ROOF COVERING (SLATE SHOWN)
ROOF COVERING (SLATE SHOWN)
SLATE/TILING BATTEN
SLATE/TILING BATTEN
BREATHER MEMBRANE
ROOFING FELT
RAFTER
RAFTER
SuperQuilt INSULATION
JOINTS YBS FOIL TAPED
SuperQuilt INSULATION
JOINTS YBS FOIL TAPED
PLASTERBOARD & FINISH
PLASTERBOARD & FINISH
25MM BATTENS
25MM BATTENS
EXPOSED BEAM
EXPOSED BEAM
Between Rafter U-value calculation
Construction
Outside Surface Resistance
Tiles
Tile Battens
Breather Membrane
Battens
SuperQuilt
Rafters
Plasterboard
Inside Surface Resistance
Thickness
Thermal
(mm)
Conductivity
(W/mK)
10.00
25.00
25.00
25.00
150.00
12.50
0.190
-
Behind Purlin U-value calculation
Thermal
Resistance
(m2K/W)
0.100
0.000
0.000
0.000
6.100
0.000
0.066
0.100
Construction
Outside Surface Resistance
Tiles
Tile Battens
Breather Membrane
Rafters
SuperQuilt
Battens
Plasterboard
Inside Surface Resistance
U-Value, Combined Method: 0.16W/m2K
(lower limit = 6.366m2K/W, upper limit = 6.366m2K/W)
Thickness
Thermal
(mm)
Conductivity
(W/mK)
10.00
25.00
150.00
25.00
25.00
12.50
0.190
-
U-Value, Combined Method: 0.16W/m2K
(lower limit = 6.366m2K/W, upper limit = 6.366m2K/W)
page 7
Thermal
Resistance
(m2K/W)
0.100
0.000
0.000
0.000
6.100
0.000
0.066
0.100
rooflight details
Rooflight ‘Under Rafter’ Side detail
Rooflight Frame
Flashing
Tiles/Slate
Tile/Slate Batten
Breather Membrane
Counter
Batten
SuperQuilt
Rafters
Rooflight Under Rafter Detail
Rooflight Over Rafter Detail
Rooflight
Counter batten
Rooflight
Flashing
Flashing
Tile/Slate batten
Tile/Slate batten
Tiles/Slates
Tiles/Slates
SuperQuilt
Breather membrane
Breather membrane
Rafters
Rafters
SuperQuilt
Plasterboard
Plasterboard on battens
vent/light-pipe details
flashings details
Collar/Flashing
Tiles/Slate
Tile/Slate Batten
Breather Membrane
Flashing
Counter
Batten
Tiles/Slate
Tile/Slate Batten
Breather Membrane
SuperQuilt
Rafters
Vent - over rafter detail
SuperQuilt is fixed above rafters as per fixing details and turned up at the vent and
sealed with YBS Foil Tape. Battens are
placed on the rafters above the SuperQuilt.
A breather membrane is fixed above the
battens and finished by turning up at the
vent and sealing to the vent. Tile battens are
fixed in place. The flashing for the vent is fitted above the tile battens and then tiles.
Counter
Batten
SuperQuilt
Rafters
Flashings - over rafter detail
SuperQuilt is fixed above rafters as per fixing details and turned up
at the wall. A batten is placed on the rafter to hold the SuperQuilt
tight against the wall. A breather membrane is fixed above the battens and finished by turning up behind the flashing. Tile battens are
fixed in place. The flashing is fitted above the tile battens and then
tiles.
page 8
eves details
Over Rafter Fixing Details
Under Rafter Fixing Details
SuperQuilt is stapled to the rafters. At the eves the SuperQuilt is
cut and taken down between the rafters to the cavity wall insulation or the wall plate. The material needs to be sealed with staples
and tape to the rafters and the cavity wall insulation or wall plate
to create an airtight envelope.
SuperQuilt is stapled to the underside of the rafters. At the eves the
SuperQuilt is cut and taken down between the joists to the cavity
wall insulation or the wall plate. The material needs to be sealed
with staples and tape to the joists and the cavity wall insulation or
wall plate to create an airtight envelope.
Tiles
Tile Battens
Battens
Counter Battens
Ventilated Air Space
SuperQuilt Foil
Taped Joints
Felt
Rafter
Breather Membrane
Rafter
Tiles
Battens
Plasterboard
SuperQuilt Foil
Taped Joint
Tilt Board
Tilt Board
Joist
Gutter
Fascia
Board
Joist
Timber Wallplate
Gutter
Plasterboard
Plasterboard
Timber Wall Plate
Wall Insulation
Fascia
Board
Internal Leaf
External Leaf
Internal Leaf
External Leaf
Wall Insulation
valley details
Lead Gutter
Mortar
Pointing
Lead Gutter
Mortar
Pointing
Tiles
Tiles
Tile Battens
Tile Battens
Felt Membrane
Felt Membrane
SuperQuilt
Counter Battens
Foil Taped Joints
SuperQuilt
Rafters
Foil Taped Joints
Plasterboard
Rafters
Battens
Plasterboard
downlighter details
Downlighters Fixing Details
A circular hole is cut in the SuperQuilt to clear the
Downlight
Install the SuperQuilt as per fixing instructions. There needs to be a 25mm
clear cavity between the SuperQuilt and the down lighter. Locate where the
light will fit if there is not a 25mm clear cavity cut a hole in the SuperQuilt, with
a radius 25mm larger than the down lighters. Seal the cut edge of the SuperQuilt with YBS Foil Tape. Fix the plasterboard and fit the light. We recommend fire hoods are used with all sunken lights.
general instructions
For Roof Applications
Fixing Details
• SuperQuilt is designed to overlap each layer of insulation by
75mm and continually seal along the joints with YBS Foil Tape.
• No special equipment is needed to install SuperQuilt.
• SuperQuilt can be cut with a craft knife or a sharp pair of scissors.
• SuperQuilt can easily be fixed with staples at regular intervals
(minimum staple depth is 14mm).
• SuperQuilt is at the most effective with a 25mm minimum air
gap on either side. Using battens can create this gap. This will
give you the maximum insulation benefit.
• Light Weight - only 13Kg per each 1.5m x 10m roll.
• Low Bulk
- 25mm thickness - approximately equivalent to
- 270mm Mineral Wool/Fibre
• Tear resistant.
• No special tools required Easily cut with scissors .
• Fix to beams or battens with staple gun.
• No protective clothing/handling required.
• Joints can be sealed with YBS Foil Tape.
• Keeps heat in during winter.
• Keeps heat out during summer.
• Easy to fit - suitable for professional or DIY use.
• Easy to store.
MANUFACTURED IN UK AND MADE
TO A QUALITY SYSTEM MEETING THE
REQUIREMENTS OF BS EN ISO 9002
Yorkshire Building Services (WHITWELL) Ltd
Tel:
01909 721662
Fax:
01909 721442
Crags Industrial Park, Morven Street, Creswell, Derbyshire, S80 4AJ
E-Mail:
[email protected]
Web:
www.ybsinsulation.com
© Yorkshire Building Services ( WHITWELL ) Ltd.
page 9
Hot box testing approval
BDA: BPD 08-275
BDA: BPD 08-276
BDA: BPD 08-277
Agrément Tested
Certification No:
BPD 08-275
BPD 08-276
BPD 08-277
SuperQuilt is a very flexible, easy to fit, multilayer insulation that offers tremendous thermal
benefits.
Hot box testing confirms high thermal resistance of 2.51M2K/W for SuperQuilt accompanied by a 25mm air cavity either side of the
material.
The introduction of a unique method of
stitching reduces cold bridging commonly
seen with this type of insulation material.
MANUFACTURED IN UK AND MADE
TO A QUALITY SYSTEM MEETING THE
REQUIREMENTS OF BS EN ISO 9002
How does SuperQuilt Work?
Due to the special composition of multi-layers of
insulation SuperQuilt effectively deals with all
forms of energy transfer (i.e. conduction, convection and radiation). SuperQuilt works most effectively by reflecting infra-red radiation.
This means that not only is SuperQuilt effective in
winter by reflecting heat back into the building and
cold out, but also in summer Super-Quilt is a very effective solar over heating barrier reducing the need
for artificial cooling systems, preventing uncomfortable heat build up in the roof.
Accreditation & Testing
Thermal
Resistance of
Product Air
Layers and Bridging
Tensile
Strength
Parallel to
faces
2.51 m2K/W
142 kPA
Flammability
Water
Vapour
Resistance
Emmissivity
of Outer Layer
1569 MNs/g
0.05
Class E
Class 1 surface
spread of flame
BRE Report number 223653.1
BRE was commissioned by YBS Insulation to assess the vapour transmission of SuperQuilt.
The vapour permeability was used to calculate the vapour resistance (Rv) of the material.
BS EN 12667:2001
Thermal performance of building materials and products. Determination of thermal resistance by means
of guarded hot plate and heat flow meter methods. Products of high and medium thermal resistance
BS EN 822:1995
Thermal insulating products for building applications. Determination of length and width
BS EN 1602:1997
Thermal insulating products for building applications. Determination of the apparent density
BS EN 1608:1997
Thermal insulating products for building applications. Determination of tensile strength parallel to
faces
BS EN 12572:1999
Artificial climbing structures. Protection points, stability requirements and test methods
BS EN 13501-1:2002
Fire classification of construction products and building elements. Classification using test data from
reaction to fire tests
BS EN 1604:1997
Thermal insulating products for building applications. Determination of dimensional stability under
specified temperature and humidity conditions
Further details on all testing are available from the YBS technical department on 01909 721662
page 10
Two layer application 0.19 U-Value
SuperQuilt Over Rafter Application
ROOF COVERING (SLATE SHOWN)
SLATE/TILING BATTEN
SuperQuilt is fast and simple to install. With great benefits, keeping
rafter depths to a minimum, lightweight and high insulation values.
BREATHER MEMBRANE
ON TOP OF COUNTER BATTEN
Over Rafter Fixing Details
SuperQuilt is rolled out over the rafters horizontally or vertically
and stapled in position. All joints are taped with YBS Foil Tape.
RAFTER
At the eaves SuperQuilt is cut around the rafters and sealed to the
Cavity wall insulation or wall plate.
25MM
COUNTER
BATTEN
Battens are placed parallel with the rafters and fixed.
A breather-membrane is to be fitted above the battens in accordance with the manufacturer’s fixing details.
Tile battens and tiles are then fitted.
Under Rafter Fixing Details
PLASTERBOARD
SuperQuilt is rolled out to the under side of the rafters horizontally
or vertically and stapled in position. All joints are taped with YBS
Foil Tape.
SuperQuilt INSULATION
ALL JOINTS YBS FOIL TAPED
At the eaves SuperQuilt is sealed to the Cavity wall insulation or
wall plate.
Counter battens are placed parallel or perpendicular with the
rafters and fixed.
Two Layer U-value calculation
Construction
Outside Surface Resistance
Tiles
Tile Battens
Breather Membrane
Battens
SuperQuilt
Rafters
SuperQuilt
Counter Battens
Plasterboard
Inside Surface Resistance
Thickness
Thermal
(mm)
Conductivity
(W/mK)
10.00
25.00
25.00
25.00
150.00
25.00
25.00
12.50
0.190
-
Thermal
Resistance
(m2K/W)
0.040
0.000
0.000
0.000
2.501
0.000
2.510
0.000
0.066
0.130
Plasterboard can then be fixed to the counter battens with no need
for a vapour control layer.
PLEASE EMAIL [email protected] WITH YOUR
CONSTRUCTION DETAILS FOR
A U-VALUE CALCULATION
U-Value, Combined Method: 0.19W/m2K
(lower limit = 5.256m2K/W, upper limit = 5.256m2K/W)
page 11
SuperQuilt with additional insulation
SuperQuilt With PUR Between Rafter (U-Value 0.2)
SuperQuilt With PUR Between Rafter (U-Value 0.2)
ROOF COVERING (SLATE SHOWN)
ROOF COVERING (SLATE SHOWN)
SLATE/TILING BATTEN
SLATE/TILING BATTEN
BREATHER MEMBRANE
ON TOP OF COUNTER BATTEN
BREATHER MEMBRANE
ON TOP OF COUNTER BATTEN
RAFTER
RAFTER
25MM
COUNTER
BATTEN
25MM
COUNTER
BATTEN
PUR
PUR
PLASTERBOARD
PLASTERBOARD
SuperQuilt INSULATION
ALL JOINTS YBS FOIL TAPED
SuperQuilt INSULATION
ALL JOINTS YBS FOIL TAPED
PUR between rafters (400 ctr) U-value calculation
Construction
Outside Surface Resistance
Tiles
Tile Battens
Breather Membrane
Battens
SuperQuilt
Rafters
PUR
Plasterboard
Inside Surface Resistance
PUR below rafters U-value calculation
Thickness
Thermal
Thermal
(mm)
Conductivity Resistance
(W/mK)
(m2K/W)
0.040
10.00
0.000
25.00
0.000
25.00
0.000
25.00
2.510
50.00
0.000
65.00
0.023
2.826
12.50
0.190
0.066
0.130
Construction
Outside Surface Resistance
Tiles
Tile Battens
Breather Membrane
Battens
SuperQuilt
Rafters
PUR
Plasterboard
Inside Surface Resistance
U-Value, Combined Method: 0.20W/m2K
(lower limit = 4.630m2K/W, upper limit = 5.134m2K/W)
10.00
25.00
25.00
25.00
50.00
60.00
12.50
-
0.023
0.190
-
10.00
25.00
25.00
25.00
150.00
50.00
12.50
-
Thermal
Thermal
Conductivity Resistance
(W/mK)
(m2K/W)
0.040
0.000
0.000
0.000
2.510
0.000
0.023
2.174
0.190
0.066
0.130
U-Value, Combined Method: 0.20W/m2K
(lower limit = 4.920m2K/W, upper limit = 4.920m2K/W)
PUR between rafters (600 ctr) U-value calculation
Outside Surface Resistance
Tiles
Tile Battens
Breather Membrane
Battens
SuperQuilt
Rafters
PUR
Plasterboard
Inside Surface Resistance
Thickness
(mm)
0.040
0.000
0.000
0.000
2.510
0.000
2.609
0.066
0.130
FOR FURTHER INFORMATION PLEASE CALL
01909 721662
U-Value, Combined Method: 0.20W/m2K
(lower limit = 4.703m2K/W, upper limit = 5.084m2K/W)
page 12
SuperQuilt with additional insulation
SuperQuilt can be used with
additional insulation to meet
part L regulations.
SuperQuilt With PUR Between Rafter (U-Value 0.2)
SuperQuilt With PUR Between Rafter (U-Value 0.16)
ROOF COVERING (SLATE SHOWN)
ROOF COVERING (SLATE SHOWN)
SLATE/TILING BATTEN
SLATE/TILING BATTEN
BREATHER MEMBRANE
ON TOP OF COUNTER BATTEN
BREATHER MEMBRANE
ON TOP OF COUNTER BATTEN
RAFTER
RAFTER
25MM
COUNTER
BATTEN
25MM
COUNTER
BATTEN
PUR
PUR
PLASTERBOARD
PLASTERBOARD
SuperQuilt INSULATION
ALL JOINTS YBS FOIL TAPED
SuperQuilt INSULATION
ALL JOINTS YBS FOIL TAPED
PUR below rafters U-value calculation
SuperQuilt over with PUR between rafters U-value calculation
Construction
Thickness
Thermal
Thermal
(mm)
Conductivity Resistance
(W/mK)
(m2K/W)
Outside Surface Resistance
0.040
Tiles
10.00
0.000
Tile Battens
25.00
0.000
Breather Membrane
Rafter Cavity (bridged: 8.3% timber)
75.00
0.274
PUR (between rafters)
60.00
0.023
2.609
Rafters
25.00
0.000
SuperQuilt
25.00
2.510
Counter Batten
25.00
0.000
Plasterboard
12.50
0.190
0.066
Inside Surface Resistance
0.130
U-Value, Combined Method: 0.20W/m2K
(lower limit = 4.633m2K/W, upper limit = 5.287m2K/W)
SuperQuilt over with PUR between rafters U-value calculation
(W/mK)
Outside Surface Resistance
Tiles
10.00
Tile Battens
25.00
Breather Membrane
Rafter Cavity (bridged: 8.3% timber)
75.00
PUR (between rafters) (bridged: 8.3% timber)
55.00
0.023
Rafters
25.00
SuperQuilt
25.00
Counter Batten
25.00
Plasterboard
12.50
0.190
Inside Surface Resistance
2
U-Value, Combined Method: 0.20W/m K
(lower limit = 4.803m2K/W, upper limit = 5.231m2K/W)
(m2K/W)
0.040
0.000
0.000
0.274
2.391
0.000
2.510
0.000
0.066
0.130
Construction
Outside Surface Resistance
Tiles
Tile Battens
Breather Membrane
Battens
SuperQuilt
Rafters
PUR (bridged: 8.3% timber)
Rafters
SuperQuilt
Plasterboard
Inside Surface Resistance
Thickness
Thermal
Thermal
(mm)
Conductivity Resistance
(W/mK)
(m2K/W)
0.040
10.00
0.000
25.00
0.000
25.00
0.000
25.00
2.501
50.00
0.000
25.00
0.023
1.087
50.00
0.000
25.00
2.510
12.50
0.190
0.066
0.130
U-Value, Combined Method: 0.16W/m2K
(lower limit = 6.060m2K/W, upper limit = 6.259m2K/W)
PLEASE EMAIL [email protected] WITH YOUR
CONSTRUCTION DETAILS FOR
A U-VALUE CALCULATION
page 13
exposed rafters close boarding detail
SuperQuilt can be used over
close boarding. Where boarding
for structural support, SuperQuilt can be fitted above the
boarding creating cavities with
counter battens.
Fixing Details
Close boarding is fixed above the rafters. Counter battens are fixed parallel with the rafters through the
boarding into the rafters with clout nails.
SuperQuilt is rolled out onto the counter battens horizontally or vertically and stapled in position. All joints are taped with
YBS Foil Tape.
At the eaves SuperQuilt is cut around the rafters and sealed to the
Cavity wall insulation or wall plate to create an airtight envelope.
Battens are placed on top of the SuperQuilt, parallel with the rafters
and fixed in to the counter battens. A breather membrane is then fitted in accordance with the manufacturers fitting instructions.
Tile battens and tiles can then be fitted.
Recessed and fixed between rafters
SuperQuilt can be fitted
between rafters. In situations where head room
is crucial SuperQuilt is recessed into the rafter
void to allow plasterboard to be fitted directly to the SuperQuilt
on the underside of the
rafters.
Over Rafter Fixing Details
Under Rafter Fixing Details
Where roof height is critical SuperQuilt can be recessed between
the rafters.
A. SuperQuilt is stapled to the top of the first rafter.
B.SuperQuilt is recessed into the rafter void and fixed by staples
or with battens.
C.The material is then fixed to opposing rafter as per instruction B.
D. SuperQuilt is then wrapped around the rafter and the procedure
starts again.
Once all the SuperQuilt is fitted, all joints should be taped using
YBS Foil Tape.
A breather membrane is then fitted in accordance with the manufacturers fitting instructions.
Tile batten and tiles can then be fitted.
Where roof head room is essential SuperQuilt can be recessed between the rafters.
1. SuperQuilt is stapled to the underside of the first rafter.
2. SuperQuilt is recessed into the rafter void and fixed by staples
or with battens.
3. The material is then fixed to opposing rafter as per instruction 2.
4. SuperQuilt is then wrapped around the rafter and the procedure
starts again.
Once all the SuperQuilt is fitted, all joints should be taped using
YBS Foil tape.
Plasterboard can then be fixed directly to the underside of the
rafters below the SuperQuilt.
SuperQuilt Over Rafter Application
SuperQuilt Under Rafter Application
ROOF COVERING (TILES SHOWN)
SLATE/TILING BATTEN
BREATHER MEMBRANE
ROOF COVERING (TILES SHOWN)
SLATE/TILING BATTEN
ROOFING FELT
ON TOP OF
RAFTERS
D
A
PUR
C
B
RAFTERS
3
2
PUR
RAFTERS
BATTEN
OR STAPLE
SuperQuilt
INSULATION
JOINTS YBS FOIL
TAPED
BATTEN
OR STAPLE
1
4
PLASTERBOARD AND FINISH
PLASTERBOARD AND FINISH
page 14
SuperQuilt
INSULATION
JOINTS YBS FOIL
TAPED
SuperQuilt is the solution to difficult details e.g. around purlins
and other obstructions.
purlin details
Behind Purlins fixing details
SuperQuilt is fixed horizontally or vertically and stapled to the underside of the the rafters.
At the purlins the SuperQuilt is cut and pushed behind the purlins
then taped to the next piece at the opposing side of the purlin.
Battens are fixed through the SuperQuilt into the rafters.
Plasterboard can then be fixed to the battens.
Between Purlins fixing details
SuperQuilt is fixed horizontally or vertically and stapled to the underside of the the rafters.
At the purlins the SuperQuilt is turned up at stapled in place.
Battens are fixed through the SuperQuilt into the rafters, at the
purlins the battens are fixed into the rafters crushing the SuperQuilt
tightly against the purlins.
Plasterboard can then be fixed to the battens.
Between Purlins
Around Purlins
ROOF COVERING (SLATE SHOWN)
ROOF COVERING (SLATE SHOWN)
SLATE/TILING BATTEN
SLATE/TILING BATTEN
BREATHER MEMBRANE
ROOFING FELT
RAFTER
RAFTER
PUR
PUR
SuperQuilt INSULATION
JOINTS YBS FOIL TAPED
SuperQuilt INSULATION
JOINTS YBS FOIL TAPED
PLASTERBOARD & FINISH
PLASTERBOARD & FINISH
25MM BATTENS
25MM BATTENS
EXPOSED BEAM
EXPOSED BEAM
vent/light-pipe details
flashings details
Collar/Flashing
Flashing
Tiles/Slate
Tiles/Slate
Tile/Slate Batten
Breather Membrane
Counter
Batten
PUR
SuperQuilt
Tile/Slate Batten
Breather Membrane
Counter
Batten
Rafters
PUR
SuperQuilt
Rafters
Vent - over rafter detail
Flashings - over rafter detail
SuperQuilt is fixed above rafters as per fixing details and turned up at
the vent and sealed with YBS Foil Tape. Battens are placed on the
rafters above the SuperQuilt. A breather membrane is fixed above the
battens and finished by turning up at the vent and sealing to the vent.
Tile battens are fixed in place. The flashing for the vent is fitted above
the tile battens and then tiles.
SuperQuilt is fixed above rafters as per fixing details and turned up
at the wall. A batten is placed on the rafter to hold the SuperQuilt
tight against the wall. A breather membrane is fixed above the battens and finished by turning up behind the flashing. Tile battens are
fixed in place. The flashing is fitted above the tile battens and then
tiles.
page 15
general instructions
eaves details
Over Rafter Fixing Details
Fixing Details
SuperQuilt is stapled to the rafters. At the eaves the SuperQuilt is
cut and taken down between the rafters to the cavity wall insulation or the wall plate. The material needs to be sealed with staples
and taped to the rafters and the cavity wall insulation or wall plate
to create an airtight envelope.
• SuperQuilt is designed to overlap each layer of insulation by
75mm and continually sealed along the joints with YBS Foil
Tape.
• No special equipment is needed to install SuperQuilt.
• SuperQuilt can be cut with a craft knife or a sharp pair of scissors.
• SuperQuilt can easily be fixed with staples at regular intervals
(minimum staple depth is 14mm).
• SuperQuilt is most effective with a 25mm minimum air gap on
either side. Using battens can create this gap. This will give you
the maximum insulation benefit.
Under Rafter Fixing Details
SuperQuilt is stapled to the underside of the rafters. At the eaves
the SuperQuilt is cut and taken down between the joists to the cavity wall insulation or the wall plate. The material needs to be sealed
with staples and taped to the joists and the cavity wall insulation
or wall plate to create an airtight envelope.
For Roof Applications
Tiles
• Light Weight - only 13Kg per each 1.5m x 10m roll.
• Low Bulk
- 40mm thickness
• Tear resistant.
• No special tools required Easily cut with scissors .
• Fix to beams or battens with staple gun.
• No protective clothing/handling required.
• Joints can be sealed with YBS Foil Tape.
• Keeps heat in during winter.
• Keeps heat out during summer.
• Easy to fit - suitable for professional or DIY use.
• Easy to store.
Battens
Counter Battens
SuperQuilt Foil
Taped Joints
Rafter
Breather Membrane
Plasterboard
Tilt Board
Fascia
Board
Joist
Timber Wallplate
Gutter
Plasterboard
Wall Insulation
Internal Leaf
External Leaf
valley details
Lead Gutter
calculations
Mortar
Pointing
SuperQuilt Over Rafters - R Value 2.51
Tiles
Tile Battens
Felt Membrane
Counter Battens
U Value 0.2 W/m2K
U Value 0.2 W/m2K
U Value 0.19 W/m2K
U Value 0.2 W/m2K
U Value 0.19 W/m2K
U Value 0.18 W/m2K
U Value 0.16 W/m2K
SuperQuilt
Foil Taped Joints
Rafters
Counter Battens
Plasterboard
U Value 0.2 W/m2K
U Value 0.16 W/m2K
downlighter details
Extra Insulation Between Rafters
400mm centres
600mm centres
60mm PUR
60mm PUR
105mm 0.043 Non-Itch 43
100mm 0.04 Non-Itch 43
105mm 0.039 Non-Itch 39
100mm 0.039 Non-Itch 39
105mm 0.040 Mineral Fibre 100mm 0.040 Mineral Fibre
110mm 0.034 Mineral Fibre 100mm 0.034 Mineral Fibre
110mm 0.032 Mineral Fibre 100mm 0.032 Mineral Fibre
110mm PUR
100mm PUR
Extra Insulation Under Rafters
50mm PUR
90mm PUR
SuperQuilt Under Rafters - R Value 2.51
A circular hole is cut in the SuperQuilt to clear the
Downlight
U Value 0.2 W/m2K
U Value 0.2 W/m2K
U Value 0.19 W/m2K
U Value 0.2 W/m2K
U Value 0.19 W/m2K
U Value 0.18 W/m2K
U Value 0.16 W/m2K
U Value 0.16 W/m2K
Downlighters Fixing Details
Install the SuperQuilt as per fixing instructions. There needs to be
a 25mm clear cavity between the SuperQuilt and the down lighter.
Locate where the light will fit if there is not a 25mm clear cavity, cut
a hole in the SuperQuilt with a radius 25mm larger than the down
lighters. Seal the cut edge of the SuperQuilt with YBS Foil Tape.
Fix the plasterboard and fit the light. We recommend fire hoods
are used with all sunken lights.
Extra Insulation Between Rafters
400mm centres
600mm centres
60mm PUR
60mm PUR
100mm 0.043 Non-Itch 43
100mm 0.04 Non-Itch 43
90mm 0.039 Non-Itch 39
90mm 0.039 Non-Itch 39
95mm 0.040 Mineral Fibre
90mm 0.040 Mineral Fibre
100mm 0.034 Mineral Fibre 95mm 0.034 Mineral Fibre
100mm 0.032 Mineral Fibre 95mm 0.032 Mineral Fibre
110mm PUR
90mm PUR
150mm 0.039 Non-Itch 39
140mm 0.039 Non-Itch 39
SuperQuilt Under & Over Rafters - R Value 2.51
U Value 0.19 W/m2K
U Value 0.16 W/m2K
U Value 0.16 W/m2K
Extra Insulation Between Rafters
600mm centres
400mm centres
No Insulation
No Insulation
30mm PUR
25mm PUR
45mm 0.039 Non-Itch 39
40mm 0.039 Non-Itch 39
Yorkshire Building Services (WHITWELL) Ltd
Tel:
01909 721662
Fax:
01909 721442
Crags Industrial Park, Morven Street, Creswell, Derbyshire, S80 4AJ
E-Mail:
[email protected]
Web:
www.ybsinsulation.com
© Yorkshire Building Services ( WHITWELL ) Ltd.
page 16
YBS 167 06/08
MANUFACTURED IN UK AND MADE
TO A QUALITY SYSTEM MEETING THE
REQUIREMENTS OF BS EN ISO 9002

Similar documents

Superquilt Multi Layer Insulation Blanket

Superquilt Multi Layer Insulation Blanket Installation of SuperQuilt for over rafter applications and additional insulation products should be in accordance with the certificate, YBS fixing instructions and current good building practice. ...

More information

SuperQuilt - Datasheet

SuperQuilt - Datasheet achieving a high thermal resistance of 2.50m²K/W for SuperQuilt accompanied by a 25mm air cavity either side of the material.

More information

SuperQuilt - YBS Insulation

SuperQuilt - YBS Insulation insulation thermally tested in accordance with EN16012 achieving a high thermal resistance of 2.50m²K/W for SuperQuilt accompanied by a 25mm air cavity either side of the material.

More information

Multi-layer Insulation Blanket for Floors - superquilt

Multi-layer Insulation Blanket for Floors - superquilt SuperQuilt is a very flexible, easy to fit, multilayer insulation thermally tested in accordance with EN12667 achieving a high core thermal resistance of 1.38m²K/W for SuperQuilt.

More information