superquilt all:Layout 2
Transcription
Multi-layer Insulation Blanket for use in Roofs Massive Thermal Insulation in a Thin, Flexible, Multi-layer Membrane HIGHEST PERFORMING MULTI-FOIL ON FULLY INDEPENDENTLY THE MARKET TESTED FULLY CERTIFIED KEEPS YOUR HOUSE COOLER IN SUMMER CAN MEET BUILDING REGULATIONS (ALWAYS MEETS REGULATIONS CHECK WITHBUILDING LOCAL BUILDING CONTROL) IDEAL FOR LOFT MEETS 0.16CONVERSIONS U-VALUE! FAST FAST AND AND SIMPLE SIMPLE INSTALLATION INSTALLATION LIGHTWEIGHT, THIN AND FLEXIBLE LIGHTWEIGHT AND FLEXIBLE KEEPS KEEPS YOUR YOUR HOUSE HOUSE WARMER WARMER IN IN WINTER WINTER KEEPS KEEPS YOUR YOUR HOUSE HOUSE COOLER COOLER IN IN SUMMER SUMMER EFFECTIVE SOLAR OVER HEATING KEEPS YOUR HOUSE COOLER IN BARRIER SUMMER LABC 362-3-7138 CIM 122/R3 167855 BDA Agrément Nr. BPD 08-275, BPD 08-276, BPD 08-277 Contents In situ testing approval CIM 122/R3 LABC 362-3-7138 P3................................................................................Testing Information P4..............................................Over/under rafter application P5.....................Exposed rafter close boarding detail P6.......................Recessed and fixed between rafters P7.........................................................................................................Purlin detail P8..............................................................................................Rooflight detail P9...........................................Eves/valley/downlighter detail Hot box testing approval BDA: BPD 08-275 BDA: BPD 08-276 BDA: BPD 08-277 P10.............................................................................Testing Information P11..........................Two layer application 0.19 U-Value P12..................SuperQuilt with additional insulation P13..................SuperQuilt with additional insulation P14....................................................................Close boarding detail P15.....................................................................................................Purlin detail P16.......................................Eves/valley/downlighter detail page 2 In situ testing approval CIM 122/R3 LABC 362-3-7138 SuperQuilt is a very flexible, easy to fit, multilayer insulation that offers tremendous thermal benefits. Tests have shown that SuperQuilt provides insulation equal to 270 mm of glass wool when installed in a pitched roof situation. SuperQuilt now has full certification with Local Authority Building Control. How does SuperQuilt Work? Due to the special composition of multi-layers of insulation SuperQuilt effectively deals with all forms of energy transfer (i.e. conduction, convection and radiation). SuperQuilt works most effectively by reflecting infra-red radiation. This means that not only is SuperQuilt effective in winter, by reflecting heat back into the building and cold out, but also in summer Super-Quilt is a very effective solar over heating barrier reducing the need for artificial cooling systems, and preventing uncomfortable heat build up in the roof. BRE testing Moisture Performance of SuperQuilt BRE Report number 223653.1 BRE was commissioned by YBS Insulation to assess the vapour transmission of SuperQuilt. The vapour permeability was used to calculate the vapour resistance (Rv) of the material. The Rv was measured as 390.6MNs/g. MANUFACTURED IN UK AND MADE TO A QUALITY SYSTEM MEETING THE REQUIREMENTS OF BS EN ISO 9002 Accreditation & Testing page 3 over/under rafters application SuperQuilt is fast and simple to install. With great benefits, keeping rafter depths to a minimum, lightweight and high insulation values. Over Rafter Fixing Details Under Rafter Fixing Details SuperQuilt is rolled out over the rafters horizontally or vertically and stapled in position. All joints are taped with YBS Foil Tape. SuperQuilt is rolled out to the under side of the rafters horizontally or vertically and stapled in position. All joints are taped with YBS Foil Tape. At the eves SuperQuilt is cut around the rafters and sealed to the Cavity wall insulation or wall plate. Battens are placed parallel with the rafters and fixed. At the eves SuperQuilt is sealed to the Cavity wall insulation or wall plate. A breather-membrane is fitted in accordance with the manufacturers fixing details, above the battens. Counter battens are placed parallel or perpendicular with the rafters and fixed. Tile battens and tiles are then fitted. Plasterboard can then be fixed to the counter battens. SuperQuilt Over Rafter Application SuperQuilt Under Rafter Application ROOF COVERING (SLATE SHOWN) ROOF COVERING (SLATE SHOWN) SLATE/TILING BATTEN SLATE/TILING BATTEN BREATHER MEMBRANE ON TOP OF COUNTER BATTEN ROOFING FELT RAFTER RAFTER (VENTILATED AIR GAP) 25MM COUNTER BATTEN MIN 25 THICK BATTEN TO RETAIN INSULATION TO TOP FACE OF RAFTER SuperQuilt INSULATION ALL JOINTS YBS FOIL TAPED SuperQuilt INSULATION ALL JOINTS YBS FOIL TAPED PLASTERBOARD PLASTERBOARD Over Rafter U-value calculation Construction Outside Surface Resistance Tiles Tile Battens Breather Membrane Battens SuperQuilt Rafters Plasterboard Inside Surface Resistance Thickness Thermal (mm) Conductivity (W/mK) 10.00 25.00 25.00 25.00 150.00 12.50 0.190 - Under Rafter U-value calculation Thermal Resistance (m2K/W) 0.100 0.000 0.000 0.000 6.100 0.000 0.066 0.100 Construction Outside Surface Resistance Tiles Tile Battens Breather Membrane Rafters SuperQuilt Battens Plasterboard Inside Surface Resistance U-Value, Combined Method: 0.16W/m2K (lower limit = 6.366m2K/W, upper limit = 6.366m2K/W) Thickness Thermal (mm) Conductivity (W/mK) 10.00 25.00 150.00 25.00 25.00 12.50 0.190 - U-Value, Combined Method: 0.16W/m2K (lower limit = 6.366m2K/W, upper limit = 6.366m2K/W) page 4 Thermal Resistance (m2K/W) 0.100 0.000 0.000 0.000 6.100 0.000 0.066 0.100 exposed rafters close boarding detail SuperQuilt can be used over close boarding. In situations where exposed rafters are required or boarding for structural support, then SuperQuilt can be fitted above the boarding creating cavities with counter battens. Fixing Details Close boarding or plasterboard is fixed above the rafters. Counter battens are fixed parallel with the rafters through the boarding into the rafters with clout nails. SuperQuilt is rolled out onto the counter battens horizontally or vertically and stapled in position. All joints are taped with YBS Foil Tape. At the eves SuperQuilt is cut around the rafters and sealed to the Cavity wall insulation or wall plate to create an airtight envelope. Battens are placed on top of the SuperQuilt, parallel with the rafters and fixed in to the counter battens. A breather membrane is then fitted in accordance with the manufacturers fitting instructions. Tile battens and tiles can then be fitted. Scottish Detail Exposed Rafters Close Boarding Detail ROOF COVERING (SLATE SHOWN) SLATE/TILES SLATE/TILE BATTENS SLATE/TILING BATTEN BREATHER MEMBRANE BREATHER MEMBRANE SARKING BOARD RAFTER RAFTERS MIN 25MM THICK COUNTER BATTEN SuperQuilt INSULATION JOINTS YBS FOIL TAPED BATTENS PLASTERBOARD SuperQuilt INSULATION JOINTS YBS FOIL TAPED 25MM COUNTER BATTENS CLOSE BOARDING Scottish Detail U-value calculation Exposed Rafter Close Boarding / Plasterboard U-value calculation Construction Outside Surface Resistance Tiles Tile Battens Breather Membrane Counter Battens SuperQuilt Counter Battens Plasterboard / Plywood Rafters Inside Surface Resistance Thickness Thermal (mm) Conductivity (W/mK) 10.00 25.00 25.00 25.00 25.00 12.50 0.190 150.00 - Construction Thermal Resistance (m2K/W) 0.100 0.000 0.000 0.000 6.100 0.000 0.066 0.000 0.100 Outside Surface Resistance Tiles/Slates Tile/Slate Battens Breather Membrane Sarking Board Rafters SuperQuilt Battens Plasterboard Inside Surface Resistance Thickness Thermal (mm) Conductivity (W/mK) 10.00 25.00 18.00 150.00 25.00 25.00 12.50 0.190 - U-Value, Combined Method: 0.16W/m2K (lower limit = 6.366m2K/W, upper limit = 6.366m2K/W) U-Value, Combined Method: 0.16W/m2K (lower limit = 6.366m2K/W, upper limit = 6.366m2K/W) page 5 Thermal Resistance (m2K/W) 0.100 0.000 0.000 0.000 0.000 6.100 0.000 0.066 0.100 recessed and fixed between rafters SuperQuilt can be fitted between rafters. In situations where head room is crucial SuperQuilt is recessed in to the rafter void to allow plasterboard to be fitted directly to the SuperQuilt on the underside of the rafters. Over Rafter Fixing Details Under Rafter Fixing Details Where roof height is critical SuperQuilt can be recessed between the rafters. A. SuperQuilt is stapled to the top of the first rafter. B.SuperQuilt is recessed into the rafter void and fixed by staples or with battens. C.The material is then fixed to opposed rafter as per instruction B. D. SuperQuilt is then wrapped around the rafter and the procedure starts again. Once all the SuperQuilt is fitted all joints should be taped using YBS Foil Tape. A breather membrane is then fitted in accordance with the manufacturers fitting instructions. Tile batten and tiles can then be fitted. Where roof head room is essential SuperQuilt can be recessed between the rafters. 1. SuperQuilt is stapled to the underside of the first rafter. 2. SuperQuilt is recessed into the rafter void and fixed by staples or with battens. 3. The material is then fixed to opposed rafter as per instruction 2. 4. SuperQuilt is then wrapped around the rafter and the procedure starts again. Once all the SuperQuilt is fitted all joints should be taped using YBS Foil tape. Plasterboard can then be fixed directly to the underside of the rafters below the SuperQuilt. SuperQuilt Over Rafter Application SuperQuilt Under Rafter Application ROOF COVERING (TILES SHOWN) BREATHER MEMBRANE ROOF COVERING (TILES SHOWN) ROOFING FELT ON TOP OF RAFTERS SLATE/TILING BATTEN SLATE/TILING BATTEN D A RAFTERS C B RAFTERS 3 2 SuperQuilt INSULATION JOINTS YBS FOIL TAPED BATTEN OR STAPLE BATTEN 1 4 OR STAPLE SuperQuilt INSULATION JOINTS YBS FOIL TAPED PLASTERBOARD AND FINISH PLASTERBOARD AND FINISH Over Rafter U-value calculation Construction Outside Surface Resistance Tiles Tile Battens Breather Membrane Rafters SuperQuilt Rafters Plasterboard Inside Surface Resistance Thickness Thermal (mm) Conductivity (W/mK) 10.00 25.00 25.00 25.00 150.00 12.50 0.190 - Under Rafter U-value calculation Thermal Resistance (m2K/W) 0.100 0.000 0.000 0.000 6.100 0.000 0.066 0.100 Construction Outside Surface Resistance Tiles Tile Battens Breather Membrane Rafters SuperQuilt Rafter Plasterboard Inside Surface Resistance U-Value, Combined Method: 0.16W/m2K (lower limit = 6.366m2K/W, upper limit = 6.366m2K/W) Thickness Thermal (mm) Conductivity (W/mK) 10.00 25.00 150.00 25.00 25.00 12.50 0.190 - U-Value, Combined Method: 0.16W/m2K (lower limit = 6.366m2K/W, upper limit = 6.366m2K/W) page 6 Thermal Resistance (m2K/W) 0.100 0.000 0.000 0.000 6.100 0.000 0.066 0.100 purlin details SuperQuilt is the solution to difficult details e.g. around purlins and other obstructions. Between Purlins fixing details Behind Purlins fixing details SuperQuilt is fixed horizontally or vertically and stapled to the underside of the the rafters. SuperQuilt is fixed horizontally or vertically and stapled to the underside of the the rafters. At the purlins the SuperQuilt is turned up at stapled in place. At the purlins the SuperQuilt is cut and pushed behind the purlins then taped to the next piece at the opposed side of the purlin. Battens are fixed through the SuperQuilt into the rafters, at the purlins the battens are fixed into the rafters crushing the SuperQuilt tightly against the purlins. Battens are fixed through the SuperQuilt into the rafters. Plasterboard can then be fixed to the battens. Plasterboard can then be fixed to the battens. Between Purlins Around Purlins ROOF COVERING (SLATE SHOWN) ROOF COVERING (SLATE SHOWN) SLATE/TILING BATTEN SLATE/TILING BATTEN BREATHER MEMBRANE ROOFING FELT RAFTER RAFTER SuperQuilt INSULATION JOINTS YBS FOIL TAPED SuperQuilt INSULATION JOINTS YBS FOIL TAPED PLASTERBOARD & FINISH PLASTERBOARD & FINISH 25MM BATTENS 25MM BATTENS EXPOSED BEAM EXPOSED BEAM Between Rafter U-value calculation Construction Outside Surface Resistance Tiles Tile Battens Breather Membrane Battens SuperQuilt Rafters Plasterboard Inside Surface Resistance Thickness Thermal (mm) Conductivity (W/mK) 10.00 25.00 25.00 25.00 150.00 12.50 0.190 - Behind Purlin U-value calculation Thermal Resistance (m2K/W) 0.100 0.000 0.000 0.000 6.100 0.000 0.066 0.100 Construction Outside Surface Resistance Tiles Tile Battens Breather Membrane Rafters SuperQuilt Battens Plasterboard Inside Surface Resistance U-Value, Combined Method: 0.16W/m2K (lower limit = 6.366m2K/W, upper limit = 6.366m2K/W) Thickness Thermal (mm) Conductivity (W/mK) 10.00 25.00 150.00 25.00 25.00 12.50 0.190 - U-Value, Combined Method: 0.16W/m2K (lower limit = 6.366m2K/W, upper limit = 6.366m2K/W) page 7 Thermal Resistance (m2K/W) 0.100 0.000 0.000 0.000 6.100 0.000 0.066 0.100 rooflight details Rooflight ‘Under Rafter’ Side detail Rooflight Frame Flashing Tiles/Slate Tile/Slate Batten Breather Membrane Counter Batten SuperQuilt Rafters Rooflight Under Rafter Detail Rooflight Over Rafter Detail Rooflight Counter batten Rooflight Flashing Flashing Tile/Slate batten Tile/Slate batten Tiles/Slates Tiles/Slates SuperQuilt Breather membrane Breather membrane Rafters Rafters SuperQuilt Plasterboard Plasterboard on battens vent/light-pipe details flashings details Collar/Flashing Tiles/Slate Tile/Slate Batten Breather Membrane Flashing Counter Batten Tiles/Slate Tile/Slate Batten Breather Membrane SuperQuilt Rafters Vent - over rafter detail SuperQuilt is fixed above rafters as per fixing details and turned up at the vent and sealed with YBS Foil Tape. Battens are placed on the rafters above the SuperQuilt. A breather membrane is fixed above the battens and finished by turning up at the vent and sealing to the vent. Tile battens are fixed in place. The flashing for the vent is fitted above the tile battens and then tiles. Counter Batten SuperQuilt Rafters Flashings - over rafter detail SuperQuilt is fixed above rafters as per fixing details and turned up at the wall. A batten is placed on the rafter to hold the SuperQuilt tight against the wall. A breather membrane is fixed above the battens and finished by turning up behind the flashing. Tile battens are fixed in place. The flashing is fitted above the tile battens and then tiles. page 8 eves details Over Rafter Fixing Details Under Rafter Fixing Details SuperQuilt is stapled to the rafters. At the eves the SuperQuilt is cut and taken down between the rafters to the cavity wall insulation or the wall plate. The material needs to be sealed with staples and tape to the rafters and the cavity wall insulation or wall plate to create an airtight envelope. SuperQuilt is stapled to the underside of the rafters. At the eves the SuperQuilt is cut and taken down between the joists to the cavity wall insulation or the wall plate. The material needs to be sealed with staples and tape to the joists and the cavity wall insulation or wall plate to create an airtight envelope. Tiles Tile Battens Battens Counter Battens Ventilated Air Space SuperQuilt Foil Taped Joints Felt Rafter Breather Membrane Rafter Tiles Battens Plasterboard SuperQuilt Foil Taped Joint Tilt Board Tilt Board Joist Gutter Fascia Board Joist Timber Wallplate Gutter Plasterboard Plasterboard Timber Wall Plate Wall Insulation Fascia Board Internal Leaf External Leaf Internal Leaf External Leaf Wall Insulation valley details Lead Gutter Mortar Pointing Lead Gutter Mortar Pointing Tiles Tiles Tile Battens Tile Battens Felt Membrane Felt Membrane SuperQuilt Counter Battens Foil Taped Joints SuperQuilt Rafters Foil Taped Joints Plasterboard Rafters Battens Plasterboard downlighter details Downlighters Fixing Details A circular hole is cut in the SuperQuilt to clear the Downlight Install the SuperQuilt as per fixing instructions. There needs to be a 25mm clear cavity between the SuperQuilt and the down lighter. Locate where the light will fit if there is not a 25mm clear cavity cut a hole in the SuperQuilt, with a radius 25mm larger than the down lighters. Seal the cut edge of the SuperQuilt with YBS Foil Tape. Fix the plasterboard and fit the light. We recommend fire hoods are used with all sunken lights. general instructions For Roof Applications Fixing Details • SuperQuilt is designed to overlap each layer of insulation by 75mm and continually seal along the joints with YBS Foil Tape. • No special equipment is needed to install SuperQuilt. • SuperQuilt can be cut with a craft knife or a sharp pair of scissors. • SuperQuilt can easily be fixed with staples at regular intervals (minimum staple depth is 14mm). • SuperQuilt is at the most effective with a 25mm minimum air gap on either side. Using battens can create this gap. This will give you the maximum insulation benefit. • Light Weight - only 13Kg per each 1.5m x 10m roll. • Low Bulk - 25mm thickness - approximately equivalent to - 270mm Mineral Wool/Fibre • Tear resistant. • No special tools required Easily cut with scissors . • Fix to beams or battens with staple gun. • No protective clothing/handling required. • Joints can be sealed with YBS Foil Tape. • Keeps heat in during winter. • Keeps heat out during summer. • Easy to fit - suitable for professional or DIY use. • Easy to store. MANUFACTURED IN UK AND MADE TO A QUALITY SYSTEM MEETING THE REQUIREMENTS OF BS EN ISO 9002 Yorkshire Building Services (WHITWELL) Ltd Tel: 01909 721662 Fax: 01909 721442 Crags Industrial Park, Morven Street, Creswell, Derbyshire, S80 4AJ E-Mail: [email protected] Web: www.ybsinsulation.com © Yorkshire Building Services ( WHITWELL ) Ltd. page 9 Hot box testing approval BDA: BPD 08-275 BDA: BPD 08-276 BDA: BPD 08-277 Agrément Tested Certification No: BPD 08-275 BPD 08-276 BPD 08-277 SuperQuilt is a very flexible, easy to fit, multilayer insulation that offers tremendous thermal benefits. Hot box testing confirms high thermal resistance of 2.51M2K/W for SuperQuilt accompanied by a 25mm air cavity either side of the material. The introduction of a unique method of stitching reduces cold bridging commonly seen with this type of insulation material. MANUFACTURED IN UK AND MADE TO A QUALITY SYSTEM MEETING THE REQUIREMENTS OF BS EN ISO 9002 How does SuperQuilt Work? Due to the special composition of multi-layers of insulation SuperQuilt effectively deals with all forms of energy transfer (i.e. conduction, convection and radiation). SuperQuilt works most effectively by reflecting infra-red radiation. This means that not only is SuperQuilt effective in winter by reflecting heat back into the building and cold out, but also in summer Super-Quilt is a very effective solar over heating barrier reducing the need for artificial cooling systems, preventing uncomfortable heat build up in the roof. Accreditation & Testing Thermal Resistance of Product Air Layers and Bridging Tensile Strength Parallel to faces 2.51 m2K/W 142 kPA Flammability Water Vapour Resistance Emmissivity of Outer Layer 1569 MNs/g 0.05 Class E Class 1 surface spread of flame BRE Report number 223653.1 BRE was commissioned by YBS Insulation to assess the vapour transmission of SuperQuilt. The vapour permeability was used to calculate the vapour resistance (Rv) of the material. BS EN 12667:2001 Thermal performance of building materials and products. Determination of thermal resistance by means of guarded hot plate and heat flow meter methods. Products of high and medium thermal resistance BS EN 822:1995 Thermal insulating products for building applications. Determination of length and width BS EN 1602:1997 Thermal insulating products for building applications. Determination of the apparent density BS EN 1608:1997 Thermal insulating products for building applications. Determination of tensile strength parallel to faces BS EN 12572:1999 Artificial climbing structures. Protection points, stability requirements and test methods BS EN 13501-1:2002 Fire classification of construction products and building elements. Classification using test data from reaction to fire tests BS EN 1604:1997 Thermal insulating products for building applications. Determination of dimensional stability under specified temperature and humidity conditions Further details on all testing are available from the YBS technical department on 01909 721662 page 10 Two layer application 0.19 U-Value SuperQuilt Over Rafter Application ROOF COVERING (SLATE SHOWN) SLATE/TILING BATTEN SuperQuilt is fast and simple to install. With great benefits, keeping rafter depths to a minimum, lightweight and high insulation values. BREATHER MEMBRANE ON TOP OF COUNTER BATTEN Over Rafter Fixing Details SuperQuilt is rolled out over the rafters horizontally or vertically and stapled in position. All joints are taped with YBS Foil Tape. RAFTER At the eaves SuperQuilt is cut around the rafters and sealed to the Cavity wall insulation or wall plate. 25MM COUNTER BATTEN Battens are placed parallel with the rafters and fixed. A breather-membrane is to be fitted above the battens in accordance with the manufacturer’s fixing details. Tile battens and tiles are then fitted. Under Rafter Fixing Details PLASTERBOARD SuperQuilt is rolled out to the under side of the rafters horizontally or vertically and stapled in position. All joints are taped with YBS Foil Tape. SuperQuilt INSULATION ALL JOINTS YBS FOIL TAPED At the eaves SuperQuilt is sealed to the Cavity wall insulation or wall plate. Counter battens are placed parallel or perpendicular with the rafters and fixed. Two Layer U-value calculation Construction Outside Surface Resistance Tiles Tile Battens Breather Membrane Battens SuperQuilt Rafters SuperQuilt Counter Battens Plasterboard Inside Surface Resistance Thickness Thermal (mm) Conductivity (W/mK) 10.00 25.00 25.00 25.00 150.00 25.00 25.00 12.50 0.190 - Thermal Resistance (m2K/W) 0.040 0.000 0.000 0.000 2.501 0.000 2.510 0.000 0.066 0.130 Plasterboard can then be fixed to the counter battens with no need for a vapour control layer. PLEASE EMAIL [email protected] WITH YOUR CONSTRUCTION DETAILS FOR A U-VALUE CALCULATION U-Value, Combined Method: 0.19W/m2K (lower limit = 5.256m2K/W, upper limit = 5.256m2K/W) page 11 SuperQuilt with additional insulation SuperQuilt With PUR Between Rafter (U-Value 0.2) SuperQuilt With PUR Between Rafter (U-Value 0.2) ROOF COVERING (SLATE SHOWN) ROOF COVERING (SLATE SHOWN) SLATE/TILING BATTEN SLATE/TILING BATTEN BREATHER MEMBRANE ON TOP OF COUNTER BATTEN BREATHER MEMBRANE ON TOP OF COUNTER BATTEN RAFTER RAFTER 25MM COUNTER BATTEN 25MM COUNTER BATTEN PUR PUR PLASTERBOARD PLASTERBOARD SuperQuilt INSULATION ALL JOINTS YBS FOIL TAPED SuperQuilt INSULATION ALL JOINTS YBS FOIL TAPED PUR between rafters (400 ctr) U-value calculation Construction Outside Surface Resistance Tiles Tile Battens Breather Membrane Battens SuperQuilt Rafters PUR Plasterboard Inside Surface Resistance PUR below rafters U-value calculation Thickness Thermal Thermal (mm) Conductivity Resistance (W/mK) (m2K/W) 0.040 10.00 0.000 25.00 0.000 25.00 0.000 25.00 2.510 50.00 0.000 65.00 0.023 2.826 12.50 0.190 0.066 0.130 Construction Outside Surface Resistance Tiles Tile Battens Breather Membrane Battens SuperQuilt Rafters PUR Plasterboard Inside Surface Resistance U-Value, Combined Method: 0.20W/m2K (lower limit = 4.630m2K/W, upper limit = 5.134m2K/W) 10.00 25.00 25.00 25.00 50.00 60.00 12.50 - 0.023 0.190 - 10.00 25.00 25.00 25.00 150.00 50.00 12.50 - Thermal Thermal Conductivity Resistance (W/mK) (m2K/W) 0.040 0.000 0.000 0.000 2.510 0.000 0.023 2.174 0.190 0.066 0.130 U-Value, Combined Method: 0.20W/m2K (lower limit = 4.920m2K/W, upper limit = 4.920m2K/W) PUR between rafters (600 ctr) U-value calculation Outside Surface Resistance Tiles Tile Battens Breather Membrane Battens SuperQuilt Rafters PUR Plasterboard Inside Surface Resistance Thickness (mm) 0.040 0.000 0.000 0.000 2.510 0.000 2.609 0.066 0.130 FOR FURTHER INFORMATION PLEASE CALL 01909 721662 U-Value, Combined Method: 0.20W/m2K (lower limit = 4.703m2K/W, upper limit = 5.084m2K/W) page 12 SuperQuilt with additional insulation SuperQuilt can be used with additional insulation to meet part L regulations. SuperQuilt With PUR Between Rafter (U-Value 0.2) SuperQuilt With PUR Between Rafter (U-Value 0.16) ROOF COVERING (SLATE SHOWN) ROOF COVERING (SLATE SHOWN) SLATE/TILING BATTEN SLATE/TILING BATTEN BREATHER MEMBRANE ON TOP OF COUNTER BATTEN BREATHER MEMBRANE ON TOP OF COUNTER BATTEN RAFTER RAFTER 25MM COUNTER BATTEN 25MM COUNTER BATTEN PUR PUR PLASTERBOARD PLASTERBOARD SuperQuilt INSULATION ALL JOINTS YBS FOIL TAPED SuperQuilt INSULATION ALL JOINTS YBS FOIL TAPED PUR below rafters U-value calculation SuperQuilt over with PUR between rafters U-value calculation Construction Thickness Thermal Thermal (mm) Conductivity Resistance (W/mK) (m2K/W) Outside Surface Resistance 0.040 Tiles 10.00 0.000 Tile Battens 25.00 0.000 Breather Membrane Rafter Cavity (bridged: 8.3% timber) 75.00 0.274 PUR (between rafters) 60.00 0.023 2.609 Rafters 25.00 0.000 SuperQuilt 25.00 2.510 Counter Batten 25.00 0.000 Plasterboard 12.50 0.190 0.066 Inside Surface Resistance 0.130 U-Value, Combined Method: 0.20W/m2K (lower limit = 4.633m2K/W, upper limit = 5.287m2K/W) SuperQuilt over with PUR between rafters U-value calculation (W/mK) Outside Surface Resistance Tiles 10.00 Tile Battens 25.00 Breather Membrane Rafter Cavity (bridged: 8.3% timber) 75.00 PUR (between rafters) (bridged: 8.3% timber) 55.00 0.023 Rafters 25.00 SuperQuilt 25.00 Counter Batten 25.00 Plasterboard 12.50 0.190 Inside Surface Resistance 2 U-Value, Combined Method: 0.20W/m K (lower limit = 4.803m2K/W, upper limit = 5.231m2K/W) (m2K/W) 0.040 0.000 0.000 0.274 2.391 0.000 2.510 0.000 0.066 0.130 Construction Outside Surface Resistance Tiles Tile Battens Breather Membrane Battens SuperQuilt Rafters PUR (bridged: 8.3% timber) Rafters SuperQuilt Plasterboard Inside Surface Resistance Thickness Thermal Thermal (mm) Conductivity Resistance (W/mK) (m2K/W) 0.040 10.00 0.000 25.00 0.000 25.00 0.000 25.00 2.501 50.00 0.000 25.00 0.023 1.087 50.00 0.000 25.00 2.510 12.50 0.190 0.066 0.130 U-Value, Combined Method: 0.16W/m2K (lower limit = 6.060m2K/W, upper limit = 6.259m2K/W) PLEASE EMAIL [email protected] WITH YOUR CONSTRUCTION DETAILS FOR A U-VALUE CALCULATION page 13 exposed rafters close boarding detail SuperQuilt can be used over close boarding. Where boarding for structural support, SuperQuilt can be fitted above the boarding creating cavities with counter battens. Fixing Details Close boarding is fixed above the rafters. Counter battens are fixed parallel with the rafters through the boarding into the rafters with clout nails. SuperQuilt is rolled out onto the counter battens horizontally or vertically and stapled in position. All joints are taped with YBS Foil Tape. At the eaves SuperQuilt is cut around the rafters and sealed to the Cavity wall insulation or wall plate to create an airtight envelope. Battens are placed on top of the SuperQuilt, parallel with the rafters and fixed in to the counter battens. A breather membrane is then fitted in accordance with the manufacturers fitting instructions. Tile battens and tiles can then be fitted. Recessed and fixed between rafters SuperQuilt can be fitted between rafters. In situations where head room is crucial SuperQuilt is recessed into the rafter void to allow plasterboard to be fitted directly to the SuperQuilt on the underside of the rafters. Over Rafter Fixing Details Under Rafter Fixing Details Where roof height is critical SuperQuilt can be recessed between the rafters. A. SuperQuilt is stapled to the top of the first rafter. B.SuperQuilt is recessed into the rafter void and fixed by staples or with battens. C.The material is then fixed to opposing rafter as per instruction B. D. SuperQuilt is then wrapped around the rafter and the procedure starts again. Once all the SuperQuilt is fitted, all joints should be taped using YBS Foil Tape. A breather membrane is then fitted in accordance with the manufacturers fitting instructions. Tile batten and tiles can then be fitted. Where roof head room is essential SuperQuilt can be recessed between the rafters. 1. SuperQuilt is stapled to the underside of the first rafter. 2. SuperQuilt is recessed into the rafter void and fixed by staples or with battens. 3. The material is then fixed to opposing rafter as per instruction 2. 4. SuperQuilt is then wrapped around the rafter and the procedure starts again. Once all the SuperQuilt is fitted, all joints should be taped using YBS Foil tape. Plasterboard can then be fixed directly to the underside of the rafters below the SuperQuilt. SuperQuilt Over Rafter Application SuperQuilt Under Rafter Application ROOF COVERING (TILES SHOWN) SLATE/TILING BATTEN BREATHER MEMBRANE ROOF COVERING (TILES SHOWN) SLATE/TILING BATTEN ROOFING FELT ON TOP OF RAFTERS D A PUR C B RAFTERS 3 2 PUR RAFTERS BATTEN OR STAPLE SuperQuilt INSULATION JOINTS YBS FOIL TAPED BATTEN OR STAPLE 1 4 PLASTERBOARD AND FINISH PLASTERBOARD AND FINISH page 14 SuperQuilt INSULATION JOINTS YBS FOIL TAPED SuperQuilt is the solution to difficult details e.g. around purlins and other obstructions. purlin details Behind Purlins fixing details SuperQuilt is fixed horizontally or vertically and stapled to the underside of the the rafters. At the purlins the SuperQuilt is cut and pushed behind the purlins then taped to the next piece at the opposing side of the purlin. Battens are fixed through the SuperQuilt into the rafters. Plasterboard can then be fixed to the battens. Between Purlins fixing details SuperQuilt is fixed horizontally or vertically and stapled to the underside of the the rafters. At the purlins the SuperQuilt is turned up at stapled in place. Battens are fixed through the SuperQuilt into the rafters, at the purlins the battens are fixed into the rafters crushing the SuperQuilt tightly against the purlins. Plasterboard can then be fixed to the battens. Between Purlins Around Purlins ROOF COVERING (SLATE SHOWN) ROOF COVERING (SLATE SHOWN) SLATE/TILING BATTEN SLATE/TILING BATTEN BREATHER MEMBRANE ROOFING FELT RAFTER RAFTER PUR PUR SuperQuilt INSULATION JOINTS YBS FOIL TAPED SuperQuilt INSULATION JOINTS YBS FOIL TAPED PLASTERBOARD & FINISH PLASTERBOARD & FINISH 25MM BATTENS 25MM BATTENS EXPOSED BEAM EXPOSED BEAM vent/light-pipe details flashings details Collar/Flashing Flashing Tiles/Slate Tiles/Slate Tile/Slate Batten Breather Membrane Counter Batten PUR SuperQuilt Tile/Slate Batten Breather Membrane Counter Batten Rafters PUR SuperQuilt Rafters Vent - over rafter detail Flashings - over rafter detail SuperQuilt is fixed above rafters as per fixing details and turned up at the vent and sealed with YBS Foil Tape. Battens are placed on the rafters above the SuperQuilt. A breather membrane is fixed above the battens and finished by turning up at the vent and sealing to the vent. Tile battens are fixed in place. The flashing for the vent is fitted above the tile battens and then tiles. SuperQuilt is fixed above rafters as per fixing details and turned up at the wall. A batten is placed on the rafter to hold the SuperQuilt tight against the wall. A breather membrane is fixed above the battens and finished by turning up behind the flashing. Tile battens are fixed in place. The flashing is fitted above the tile battens and then tiles. page 15 general instructions eaves details Over Rafter Fixing Details Fixing Details SuperQuilt is stapled to the rafters. At the eaves the SuperQuilt is cut and taken down between the rafters to the cavity wall insulation or the wall plate. The material needs to be sealed with staples and taped to the rafters and the cavity wall insulation or wall plate to create an airtight envelope. • SuperQuilt is designed to overlap each layer of insulation by 75mm and continually sealed along the joints with YBS Foil Tape. • No special equipment is needed to install SuperQuilt. • SuperQuilt can be cut with a craft knife or a sharp pair of scissors. • SuperQuilt can easily be fixed with staples at regular intervals (minimum staple depth is 14mm). • SuperQuilt is most effective with a 25mm minimum air gap on either side. Using battens can create this gap. This will give you the maximum insulation benefit. Under Rafter Fixing Details SuperQuilt is stapled to the underside of the rafters. At the eaves the SuperQuilt is cut and taken down between the joists to the cavity wall insulation or the wall plate. The material needs to be sealed with staples and taped to the joists and the cavity wall insulation or wall plate to create an airtight envelope. For Roof Applications Tiles • Light Weight - only 13Kg per each 1.5m x 10m roll. • Low Bulk - 40mm thickness • Tear resistant. • No special tools required Easily cut with scissors . • Fix to beams or battens with staple gun. • No protective clothing/handling required. • Joints can be sealed with YBS Foil Tape. • Keeps heat in during winter. • Keeps heat out during summer. • Easy to fit - suitable for professional or DIY use. • Easy to store. Battens Counter Battens SuperQuilt Foil Taped Joints Rafter Breather Membrane Plasterboard Tilt Board Fascia Board Joist Timber Wallplate Gutter Plasterboard Wall Insulation Internal Leaf External Leaf valley details Lead Gutter calculations Mortar Pointing SuperQuilt Over Rafters - R Value 2.51 Tiles Tile Battens Felt Membrane Counter Battens U Value 0.2 W/m2K U Value 0.2 W/m2K U Value 0.19 W/m2K U Value 0.2 W/m2K U Value 0.19 W/m2K U Value 0.18 W/m2K U Value 0.16 W/m2K SuperQuilt Foil Taped Joints Rafters Counter Battens Plasterboard U Value 0.2 W/m2K U Value 0.16 W/m2K downlighter details Extra Insulation Between Rafters 400mm centres 600mm centres 60mm PUR 60mm PUR 105mm 0.043 Non-Itch 43 100mm 0.04 Non-Itch 43 105mm 0.039 Non-Itch 39 100mm 0.039 Non-Itch 39 105mm 0.040 Mineral Fibre 100mm 0.040 Mineral Fibre 110mm 0.034 Mineral Fibre 100mm 0.034 Mineral Fibre 110mm 0.032 Mineral Fibre 100mm 0.032 Mineral Fibre 110mm PUR 100mm PUR Extra Insulation Under Rafters 50mm PUR 90mm PUR SuperQuilt Under Rafters - R Value 2.51 A circular hole is cut in the SuperQuilt to clear the Downlight U Value 0.2 W/m2K U Value 0.2 W/m2K U Value 0.19 W/m2K U Value 0.2 W/m2K U Value 0.19 W/m2K U Value 0.18 W/m2K U Value 0.16 W/m2K U Value 0.16 W/m2K Downlighters Fixing Details Install the SuperQuilt as per fixing instructions. There needs to be a 25mm clear cavity between the SuperQuilt and the down lighter. Locate where the light will fit if there is not a 25mm clear cavity, cut a hole in the SuperQuilt with a radius 25mm larger than the down lighters. Seal the cut edge of the SuperQuilt with YBS Foil Tape. Fix the plasterboard and fit the light. We recommend fire hoods are used with all sunken lights. Extra Insulation Between Rafters 400mm centres 600mm centres 60mm PUR 60mm PUR 100mm 0.043 Non-Itch 43 100mm 0.04 Non-Itch 43 90mm 0.039 Non-Itch 39 90mm 0.039 Non-Itch 39 95mm 0.040 Mineral Fibre 90mm 0.040 Mineral Fibre 100mm 0.034 Mineral Fibre 95mm 0.034 Mineral Fibre 100mm 0.032 Mineral Fibre 95mm 0.032 Mineral Fibre 110mm PUR 90mm PUR 150mm 0.039 Non-Itch 39 140mm 0.039 Non-Itch 39 SuperQuilt Under & Over Rafters - R Value 2.51 U Value 0.19 W/m2K U Value 0.16 W/m2K U Value 0.16 W/m2K Extra Insulation Between Rafters 600mm centres 400mm centres No Insulation No Insulation 30mm PUR 25mm PUR 45mm 0.039 Non-Itch 39 40mm 0.039 Non-Itch 39 Yorkshire Building Services (WHITWELL) Ltd Tel: 01909 721662 Fax: 01909 721442 Crags Industrial Park, Morven Street, Creswell, Derbyshire, S80 4AJ E-Mail: [email protected] Web: www.ybsinsulation.com © Yorkshire Building Services ( WHITWELL ) Ltd. page 16 YBS 167 06/08 MANUFACTURED IN UK AND MADE TO A QUALITY SYSTEM MEETING THE REQUIREMENTS OF BS EN ISO 9002
Similar documents
Superquilt Multi Layer Insulation Blanket
Installation of SuperQuilt for over rafter applications and additional insulation products should be in accordance with the certificate, YBS fixing instructions and current good building practice. ...
More informationSuperQuilt - Datasheet
achieving a high thermal resistance of 2.50m²K/W for SuperQuilt accompanied by a 25mm air cavity either side of the material.
More informationSuperQuilt - YBS Insulation
insulation thermally tested in accordance with EN16012 achieving a high thermal resistance of 2.50m²K/W for SuperQuilt accompanied by a 25mm air cavity either side of the material.
More informationMulti-layer Insulation Blanket for Floors - superquilt
SuperQuilt is a very flexible, easy to fit, multilayer insulation thermally tested in accordance with EN12667 achieving a high core thermal resistance of 1.38m²K/W for SuperQuilt.