k-2 viper deluxe hqi clamp on lamp
Transcription
k-2 viper deluxe hqi clamp on lamp
K-2 VIPER DELUXE HQI CLAMP ON LAMP TRANSWORLD AQUATIC ENTERPRISES INC. Table of Contents Important Safety Instructions Parts 3—5 6 Introduction 7—9 Installation 10 Operation 11 Specifications 12 Replacing the Lamp 13 Maintenance Log 14 Notes 15 2 WARNING To guard against injury, basic safety precautions should be observed, including the following: READ ALL SAFETY INSTRUCTIONS BEFORE USE. DANGER To avoid possible electric shock, special care should be taken since water is employed in the use of aquarium equipment. For each of the following situations, do not attempt to repair yourself: return the appliance to an authorized service facility for service or discard the appliance. A. If the appliance shows any sign of abnormal noise immediately unplug from the power source. B. Carefully examine the appliance after installation. It should not be plugged in if there is water on parts not intended to be wet. C. Do not operate any appliance if it has a damaged cord or plug, or if it is malfunctioning or if it is dropped or damaged in any manner. 3 D. To avoid the possibility of the ap- pliance plug or receptacle getting wet, position aquarium stand and tank to one side of a wall mounted receptacle to prevent water from dripping onto the receptacle or plug. A “drip loop”, shown in the Figure at the right should be arranged by the user for each cord connecting an aquarium appliance to a receptacle. The ”drip loop” is that part of the cord below the level of the receptacle or the connector if an extension cord is used, to prevent water travel along the cord and coming in contact with the receptacle. If the plug or the receptacle do get wet, DON’T unplug the cord. Disconnect the fuse to the circuit breaker that supplies power to the appliance. Then unplug and examine for the presence of water in the receptacle. E. Close supervision is necessary when any appliance is used by or near children. F. To avoid injury, do not contact moving parts or hot parts such as heaters, reflectors, lamp bulbs, and etc. G. Always unplug an appliance from the outlet when not in use, before putting on or taking off parts, and before cleaning. Never yank the cord to pull plug from the outlet. Grasp the plug and pull to disconnect H. Do not use an appliance for other than intended use. The use of attachments not recommended or sold by the appliance manufacturer may cause an unsafe condition. I. Do not install or store the appliance where it will be exposed to the weather or to temperatures below freezing. 4 J. Make sure an appliance mounted on a tank is securely in- stalled before operating it. K. Read and observe all the important notices on the appliance. L. This Appliance has a polarized plug (one blade is wider than the other). As a safety feature, this plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Never use with an extension cord unless plug can be fully inserted. Do not attempt to defeat this safety feature. M. If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less amperes or watts than the appliance rating may overheat. Care should be taken to arrange the cord so that it will not be tripped over or pulled. CLEANING It is important to keep this appliance clean. Always unplug the appliance before performing maintenance or cleaning of the exterior of this pump. Wipe exposed surfaces carefully with a damp terrycloth to remove any dust or mineral deposits which may collect over time. Make sure hands are completely dry before re-plugging into an electrical outlet. SERVICING In order to assure proper electrical connections and polarity, replacement parts and servicing should be performed only by a qualified electrician. OPERATION Please carefully read the entire “Owner’s Manual” for proper operation procedures before proceeding with turning on this appliance and adding livestock such as fish, corals, and invertebrates. SAVE THESE INSTRUCTIONS 5 PARTS EXPLODED VIEW & IDENTIFICATION Description Part # Top—Lighting Hood A HQI Lamp Holder B HQI Lamp C UV Glass Shield D Bottom—Lighting Cover E Height Adjustment Arm F Extension Adjustment Arm G Tank Mounting Bracket H Tank Mounting Spacer I Rear Mounting Screws J Front Mounting Screws K Nite Vu LED—Moon Lighting L LED Remote Ballast M Fan Motor Assembly / Fan N HQI Remote Ballast O B A F C D L E N G H K O M 6 J I The Ultimate HQI Clamp on Lamp Thank you for purchasing the most comprehensive HQI Clamp on Lamp in the industry. The K-2 Viper Deluxe incorporates intense HQI metal halide light ouput for daytime viewing, along with (2) integrated Nite Vu LED moonlighting for after hours viewing. All models are equipped with a directional fan motor assembly to cool off the light fixture as well as the surface of the water with a convenient 2 speed fan control integrated at the remote ballast. Replicating Mother Nature with Versalitlity There is nothing more intense or spectacular than the vibrant rays the sun can produce. But, we sure came close to emulating the power of the sun enclosed in a compact design for the next best thing. The K-2 Viper Deluxe is guaranteed to instantly transform aquariums with fluorescent lighting into showroom display tanks with rhythmic shimmering throughout the tank and intensified light output for SPS, CLAMS, and LPS corals. The K-2 Viper Deluxe will virtually fit on any size aquarium. Our unique design allows you to angle the light right where you need it most. With 3 separate adjustment knobs you can configure the way you deem most fitting for your live inhabitants’ lighting needs. The high velocity fan motor easily cools off the fixture and puts you in control with 2 speed settings that can be set from 105163 CFM. The Nite Vu LED’s are integrated under the height adjustment arm which adds a beautiful nite-time blue shimmer. 7 Power of the Sun The K-2 Viper Deluxe Clamp on Lamp fixture is the instant solution for hobbyists who demand high intensity power in a compact exterior housing. Double Ended HQI metal halide fixtures produce a tremendous amount of light output for demanding corals and cast beautiful sparkling rays on the bottom floor of your substrate. We offer the fixtures in a 150 watt and 250 watt version to adapt to almost any possible aquarium set up imaginable. It is recommended to use 1 fixture for every 2 feet of length of aquarium. The 150 watt version is adequate for aquariums up to 18” in depth, while the 250 watt version is recommended for tanks 18” - 30” in depth. Keeping you Cool in the Sun All K-2 Viper Deluxe fixtures are equipped with a high velocity fan with 2 speed fan control located and the face of the remote ballast. The fan has a CFM rating of (L)105 – (H) 163 to exhaust heat from the fixture and the aquarium. The switch is labeled “L” and “H” to the corresponding flow rates. You can also turn off the fan by leaving the switch in the middle position. Toggle the switch up for low setting Toggle the switch in the middle for off Toggle the switch down for high setting 8 Illuminating Nocturnal Behaviors Our newest innovation to the K-2 Viper series are our (2) Nite Vu LED moonlights integrated into the cool running portion of the extension arm. These discreetly placed blue LEDs consume less than 1 watt of power, but are still strong enough to illuminate nocturnal behaviors. Nite Vu LED’s allow you to view all the activities that occur after the HQI (daytime) lamp is turned off without disturbing any of your live inhabitants as they rest. All models include individual power cord for LEDs. Hammertone Reflector All models are equipped with our new and improved larger hammertone reflector to cast 98% of the usable light back into the aquarium. HQI ballast is UL recognized and delivers consistent performance day after day while conveniently stored in your cabinet. New and improved UL recognized lamp socket holders have been installed for secure placement of the lamps while making lamp changes a snap. 9 Caution: Do Not plug into electrical power source before cables have been connected WARNING: Top Head of fixture may get very HOT, do not adjust until you turn the fixture off and allow to cool down. Mounting the Aquarium Step 1: Place mounting bracket over aquarium frame and tighten the (2) rear mounting screws Step 2: Tighten the (2) front mounting screws Step 3: Adjust the 3 screws on the arms to your desired angle. Connecting the Cables to the Ballast There are 2 cables connected to the bottom base of the fan support.. The thicker cable connects to the large HQI ballast while the thinner cable connects to the small LED ballast. HQI Cable (thicker) LED Cable (thinner) HQI Ballast LED Ballast 10 Understanding Controls on the Ballast Fuse 2 Speed Fan Control Switch HQI— On/Off Switch 120V Plug connector to wall outlet HQI Cable Connection Using on a Timer Many hobbyist prefer to automate their lighting cycles by plugging their lighting systems into timers. You can easily automate the control of the fans and the HQI lighting by plugging the 120V plug from the HQI ballast into an analog timer. The LED transformer may be plugged directly into a 120v wall outlet and does not need to be plugged into a timer. The LEDs consume less than 1 watt of energy. Once plugged into a timer, the fan speed and HQI lamp will turn on/off based on the cycle period of the timer setting. We recommend providing a photoperiod between 6-8 hours of daylight for most coral and invertebrates. 11 SPECIFICATIONS Model #: K-2-DX-150 Description: K-2 Viper Deluxe - 150 Watt HQI w/2 Speed Fan and LEDs Ballast Type: Magnetic 120V/60Hz ( UL Recognized ) Ballast Amps: 1.8A Fuse: 5 amps Lamp Kelvin: 14,000K Model #: K-2-DX-250 Description: K-2 Viper Deluxe—250 Watt HQI w/ 2 Speed Fan and LEDs Ballast Type: Magnetic 120V/60Hz ( UL Recognized ) Ballast Amps: 2.13A Fuse: 7 Amps Lamp Kelvin: 14,000K Reflector Dimensions: L- 8.25” x W- 7” x H- 2.5” Mounting Bracket Space: 1.25” For Customer Service Questions: Tel: (310) 672-4099 Fax: (310) 672-7261 Email: [email protected] www.jbjlighting.com 12 CAUTION: Always unplug before performing any maintenance. NEVER use soap, detergents, or any non-recommended cleaning agents around an aquarium. ALWAYS caution when handling the head of fixture Changing the Lamp Metal Halide lamps should be replaced out every 9-12 months to retain its’ natural color rendition and intensity. Old lamps may cause undesirable nuisance algae and impact the health of corals and invertebrates that require the correct lumens and Kelvin for survival. Step 1: Unplug the main power cord from the wall outlet and turn off the switch to the HQI ballast. Allow the fixture to cool for an hour or until the head of the fixture is at a cool temperature. Step 2: Disconnect the cables from the HQI ballast and LED ballast Step 3: Remove the fixture from the tank and place the fixture upside on the head so that the lamp faces you. Step 4: Unscrew the 4 screw located at the four corners of the light head. Remove the lamp and replace. 13 MAINTENANCE LOG Maintenance Description Date Customer Service Information For additional information or technical support, please call us at (310) 672-4099 , M-F from 9AM-5PM (Pacific Standard Time). 14 15 TransWorld Aquatic Enterprises, Inc 3730 W. Century Blvd #3 Inglewood, CA 90303 Phone: (310) 672-4099 www.jbjlighting.com 16