ADVANCED SERIES
PENDANT - 250 WATT
INSTRUCTIONS
Please read these instructions
in their entirety before attempting
to use this unit.
Energy Savers Unlimited Carson, California 90746 USA esuweb.com
1
IMPORTANT
SAFETY INSTRUCTIONS
INSTALLATION
SETUP
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
WARNING
CAUTION
1. Never connect the Aqualight Advanced fixture to
any power source while hands are wet.
1. The fixture SIDE
is for VIEW
use over covered aquariums only.
2.0
2. The fixture should not be installed inside a canopy.
2. Do not allow unit to come into direct contact with
water.
3. The fixture should not be placed directly on the aquarium.
4. For added safety, this device should be plugged into a
grounded three-prong receptacle controlled by a GFI
(Ground Fault Interrupter) circuit breaker.
3. Cut off power and stop using if the unit is submersed
or dampened by water.
4. Always leave a drip-loop in the lamp cord to prevent
water from running down the length of the cord and
reaching the ballast connectors and/or plugs.
5. Always turn fixture off and uplug the ballast power cord
before adjusting fixture or replacing lamps. Make sure to
let the fixture cool down before handling.
FRONT VIEW
1.0
Retractable
Lamp Cord
Hardware
Tension
Wing Nut
Aquarium
Ceiling-Mount Cover
Drip-Loop
IMPORTANT SAFETY NOTE
FRONT VIEW
1.1
1. Do not attach fixture to ballast until all assembly connections,
adjustments and mounting setups are completely performed.
PRE-INSTALLATION
1. Adjust the retractable lamp cord. Pull retractable
lamp-cord hardware from ceiling-mount cover. (1.0)
2. Locate tension wing nut on retractable lamp cord
hardware. (1.1)
Tension
Wing Nut
3. Turn tension wing nut clockwise and tighten the wing nut to
hold the weight of the pendant.
FRONT VIEW
4. Adjust retractable lamp cord to 12” length. (1.2)
1.2
a. Push up on pendant to retract lamp-cord.
12”
b. Pull down on pendant to extend lamp-cord.
A
1
INSTALLATION SETUP
IMPORTANT SAFETY NOTE
1. Make sure to follow the fixture and metal halide ballast
connection instructions in their entirety. Failure to follow these
directions may damage the unit and/or cause unit failure.
SIDE VIEW
3.0
BALLAST SETUP
FIXTURE AND BALLAST CONNECTION
1. Locate double-ended HQI metal halide lamp connector from
the unit. (3.0)
SAFETY: Turn off all switches and unplug all power cords
from power outlet(s). Do not plug power cords into
power outlets until fixture installation and setup is
complete.
Double-Ended HQI Metal
Halide Lamp Connector
Double-Ended HQI
Metal Halide Ballast
SIDE VIEW
2. Make sure that the double-ended HQI metal halide ballast
is unplugged and switch is in the off position.
MALE
3.1
FEMALE
3. Plug double-ended HQI metal halide lamp connector (male)
into metal halide ballast inlet (female). (3.1)
IMPORTANT! Make sure that the lamp connectors
are fully inserted into the ballast. (3.2)
START-UP OPERATION
Double-Ended HQI Metal
Halide Lamp Connector
1. Make sure all connections are completely attached
and secure.
2. Make sure that the switch is in the off position before
plugging in power cord to power source.
SIDE SECTION
Double-Ended HQI Metal
Halide Ballast Inlet
3.2
3. The ground connector must be plugged in or attached to
an outlet that is installed and grounded in accordance with
all appropriate codes and ordinances.
4. Plug the power cord into an outlet or power source and
turn the switches on. (3.3)
NOTE: It may take up to 5-10 minutes for double-ended
HQI metal halide lamp(s) to reach maximum light intensity.
CAUTION: When the double-ended HQI metal halide
ballast is turned off, wait until the double-ended HQI
metal halide lamp has completely cooled, before
turning the ballast back on.
Double-Ended HQI Metal
Halide Lamp Connector
SIDE VIEW
Grounded Outlet
Power Source
5. Verify that all lamp is lit and functioning properly.
Plug
3
Double-Ended HQI Metal
Halide Ballast Inlet
3.3
ADVANCED SERIES
MAINTENANCE
DOUBLE-ENDED HQI METAL HALIDE
LAMP REPLACEMENT
SIDE VIEW
4.0
SIDE VIEW
4.1
SAFETY: Turn off all switches and unplug all power
cords from outlet or power source before performing
maintenance.
CAUTION: Let the unit cool down before handling.
1. Remove the fixture from aquarium.
2. Place the fixture on a non-abrasive flat surface with the
bottom facing up. (4.0)
3. Pull pendant ring/reflector from black aluminum
housing. (4.1)
NOTE: Do not remove glass lens cover from pendant
ring/reflector.
4. Using a soft cloth, hold both ends of the lamp. (4.2)
Pendant
Ring/Reflector
5. Gently lift both ends of the lamp to detach from the metal
halide sockets. (4.3)
PULL
OFF
6. Remove double-ended HQI metal halide lamp.
7. Carefully install replacement double-ended HQI metal halide
lamp using a soft cloth and replace light fixture parts.
Black Aluminum
Housing
WARNING: Do not touch double-ended HQI metal halide
lamp with fingers as the oils will damage the lamp.
If contact is made with lamp, use a clean, soft, dry cloth
to remove any fingerprints from the lamp before use.
TOP VIEW
4.2
Use Soft
Cloth
REPLACEMENT PARTS
Use Soft
Cloth
53710 - 250 WATT 10,000K DOUBLE-ENDED HQI
METAL HALIDE LAMP
53712 - 250 WATT 1400K DOUBLE-ENDED HQI
METAL HALIDE LAMP
Double-Ended HQI
Metal Halide Lamp
Double-Ended HQI
Metal Halide Socket
53715 - 250 WATT 20,000K DOUBLE-ENDED HQI
METAL HALIDE LAMP
SIDE SECTION
53069 - 250 WATT DOUBLE-ENDED HQI METAL HALIDE
REPLACEMENT BALLAST
4.3
53073 - REPLACEMENT COOLING FAN
LIFT UP
LIFT UP
Double-Ended HQI
Metal Halide Lamp
Double-Ended HQI
Metal Halide Socket
4
Energy Savers Unlimited
12 Month Limited Warranty
WHAT THE WARRANTY COVERS:
Energy Savers Unlimited (Company) warrants this product (see Exclusions below) to the original purchaser
against defective material and workmanship that occurs during normal use for 12 months from the date of original
purchase. Company will, at Company's option, either repair or replace same without charge (but no cash refunds
will be made).
EXCLUSIONS:
1. Damage resulting from accident, misuse, abuse, lack of reasonable care, subjecting the product to any but the
specified electrical service, other than normal and ordinary use of the product, subjecting the product to abnormal
working conditions or any other failure not resulting from defects in materials or workmanship.
2. Damage resulting from modification, tampering with or attempted repair by anyone other than the Company.
3. Transfer of product to someone other than the original consumer purchaser.
WHAT YOU MUST DO TO ENFORCE WARRANTY:
1. Contact the Company by mail or telephone: Energy Savers Unlimited 910 E. Sandhill Ave. Carson, CA 90746
E-mail: [email protected] Tel: (310) 851-8999 or 800-678-8844 Fax: 310-851-8996 to obtain a RETURN
AUTHORIZATION NUMBER.
NOTE: Be sure to provide contact information when requesting return authorization number.
2. Deliver, mail or ship the product, together with a copy of the original bill of sale to:
Energy Savers Unlimited
910 E. Sandhill Ave.
Carson, CA 90746
You must pay any postage, shipping charges, insurance costs and other expenses to return the product to Energy
Savers Unlimited Carson, CA. However, if the necessary repairs are covered by the warranty, Company will
pay the return shipping charges to any destination within the United States or Canada.
LIMITATION OF IMPLIED WARRANTIES AND EXCLUSION OF CERTAIN DAMAGES:
THE COMPANY DISCLAIMS LIABILITY FOR INCIDENTAL AND CONSEQUENTIAL DAMAGES FOR BREACH OF ANY
EXPRESS OR IMPLIED WARRANTY, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, WITH RESPECT TO
THIS PRODUCT. THIS WRITING CONSTITUTES THE ENTIRE AGREEMENT OF THE PARTIES WITH RESPECT TO THE
SUBJECT MATTER HEREOF; NO WAIVER OR AMENDMENT SHALL BE VALID UNLESS IN WRITING SIGNED BY THE
COMPANY. Some states do not allow the exclusion or limitation of consequential damages, so the above limitation
or exclusion may not apply to you.