New features of MicroSCADA Pro

Transcription

New features of MicroSCADA Pro
© ABB Substation Automation - 1 1/14/2005
New features of
MicroSCADA Pro
-2-
MicroSCADA Pro
General
LIB 500
SYS 600
COM 500
DMS 600
IEC 61850
MicroSCADA Pro
„
SYS 600 *9.0
„
-3-
Quick Overview
New User Interface
„
Process Displays
„
Alarm List
„
Event List
„
Blocking List
„
Trends
„
IEC 61850 connectivity
„
Extended language support
„
Various improvements in the engineering tools
„
Improved integration with DMS 600
MicroSCADA Pro
-4-
„
Quick Overview
DMS 600 *4.0
„
Improved network editing
„
Event history simulation
„
Extensions in fault location algorithms
„
GPS utlisation for network editing and field crew location
„
Network status on the web
„
OPC Client
„
Etc.
MicroSCADA Pro
„
„
COM 500
„
IEC 61850 support
„
Enhanced data import
„
More alarm groups
„
More protocols
„
Etc.
LIB 500/510
„
-5-
Quick Overview
IEC 61850 support
MicroSCADA Pro
„
-6-
„
Introduction
MicroSCADA Pro
„
Next step in the development
of MicroSCADA and Open++
Opera
„
The complete and harmonized
product family for substation
Control, Network Control and
Distribution Management
Starting point
„
MicroSCADA 8.4.5
„
Opera 3.3
-7-
MicroSCADA Pro
Application Areas
„
Distribution Automation
„
Network Control
„
Substation Control
„
Substation Monitoring
„
Feeder Automation
MicroSCADA Pro
Systems
Distribution Management
Network Control
Feeder Automation
-8-
Substation Monitoring
Substation Control
MicroSCADA Pro
Position
Opera
MicroSCADA
High End Scada
position
MicroSCADA
EMS
SMS 510
CAP 5xx
DMS
SCADA
Built in local HMI or
HHHMI
Substation HMI
Substation Gateway
Graphical
Protection & Control HMI
-9-
Textual
Protection & Control HMI
Indicators
Protection & Control HMI
MicroSCADA Pro
MicroSCADA Pro
- 10 -
„
Products
MicroSCADA Pro
„
Control System SYS 600 *9.0
„
Distribution Management System DMS 600 *4.0
„
Communication Gateway COM 500 *4.1
MicroSCADA Pro
„
Network Control
„
New Process Graphics
„
„
zoom, panning and de-cluttering
Substation Control
„
Support for new standard IEC 61850
„
- 11 -
Main Requirements
IEC61850 System support
MicroSCADA Pro
„
Upgradeability and system continuity are key
factors to maintain the customers confidence in
ABB’s solutions
„
Keeps our existing customers
„
Enable our customers to relocate existing
solutions to a more modern environment.
„
Preserves a customer's existing solution
investment and the functionality and reliability.
„
Market message to new customers:
„
- 12 -
„
Evolutionary development strategy
Safe investment when using ABB’s solution.
Leverage on installed MicroSCADA base
„
3400 installations -- 820 SCADA-systems
„
Large # of trained staff in local units.
- 13 -
MicroSCADA Pro
Compatibility
„
SYS 600 *9.0 is fully backward compatible with current
applications
„
The new user interface is an additional function that
works well in parallel with the current user interface
© ABB Substation Automation - 14 1/14/2005
MicroSCADA Pro
SYS 600 *9.0
- 15 -
SYS 600
New User Interface
„
Improved look & feel
„
Improved Performance
„
More functions, flxible and
modifiable
„
New monitor type
SYS 600
„
Process displays
„
- 16 -
New Process Displays
View - Zoom Control…
„
zoom
„
pan
„
de-clutter
- 17 -
SYS 600
New Process Displays
„
Zoom, Pan & Decluttering
„
Dynamic Busbar coloring
„
Standard symbols for electrical
applications
„
Hundreds of other symbols
„
Support for standard graphics
formats and ActiveX components
„
Can be connected directly to
existing LIB process database
„
Can be used in parallell with existing
pictures
- 18 -
SYS 600
New Display Builder
„
New symbol library for electrical
applications
„
Hundreds of other symbols
„
Easy handling of own symbol
libraries
„
Generic OPC client
„
Extensive generic drawing tools
„
Flexible configuration of dynamic
behaviour (show/hide, fill, move,
color, rotate, blink, scale, etc.)
SYS 600
„
- 19 -
„
New Display Builder
Easy building of Single Line
Diagram with Drag & Drop
„
Browse the database structure
„
Drag the device to the single line
diagram
„
Done! All connections made!
Builds topology for dynamic busbar
coloring automatically
- 20 -
SYS 600
New Trends
„
All functions of current trends +
„
Improved Zoom & Pan
„
Improved performance
„
Improved look & feel
- 21 -
SYS 600
New Alarm Lists
„
Improved performance
„
Improved look & feel
„
Improved customization
„
New functions
„
Find
„
Copy/Paste
„
Texts in local language
- 22 -
SYS 600
New Event List
„
Improved performance
„
Improved look & feel
„
Improved customization
„
New functions
„
Find
„
Copy/Paste
„
Programmable coloring
„
Increased time interval (up to
one year)
„
Message Text
„
Texts in local language
- 23 -
SYS 600
New Blocking List
„
All functions of current
blocking list +
„
Improved performance
„
Improved look & feel
„
Improved customization
„
New functions
„
Find
„
Copy/Paste
„
Texts in local language
SYS 600
„
Event Conversion
„
- 24 -
Migration Tools
Adds new event handling to existing LIB database
„
Creates H-objects and links them to P-objects
„
Based on FORM-pictures and text files
SYS 600
„
DAT Export
„
- 25 -
Migration Tools
Extracts Picture Function configuration data from existing LIB
pictures to be used by new process graphics
SYS 600
„
New Event Handling Object (H)
„
To handle event & status texts
„
„
„
- 26 -
Language Support
Maps object value/state to texts
To support localisation of event & status texts
„
Text id in H-object
„
Actual language specific text in text database
To support future OPC A&E interface
SYS 600
„
New Process Object Attributes
„
„
TX - Translated Object Text
„
The value of the OX attribute translated into the current language
„
All texts now support user specific languages – also in event and alarm list
EH - Event Handling
„
„
„
- 27 -
Language Support
The name of the event handling object associated to the process object
SX - State Text
„
A descriptive text of the object state in the current language
„
Retreived through the H object
MX - Message Text
„
A descriptive text of the event in the current language
„
Retreived through the H object
SYS 600
- 28 -
„
Text Translation Tool
Support for Text
databases
SYS 600
- 29 -
„
Object Navigator
New P-object views
„
By unit number (UN)
„
By object identification (OI)
„
By OPC name (ON)
„
Support for IEC 61850 P-object types
„
Improved OI editor
SYS 600
„
„
Standard Function installation
„
Installation of LIB standard functions without pictures
„
To be used with new process displays
Import/Export
„
- 30 -
„
Object Navigator
Start export based on the active selection
Event Handling objects
„
Management of the new event handling objects
„
Create, view, modify, delete
SYS 600
- 31 -
„
Import/Export Tool
New VS Import/Export
Tool
„
Import/Export of
application objects from/to
ascii file
„
Can also operate on
selections in the object
navigator
SYS 600
- 32 -
„
Online Backup Tool
New online backup tool
„
Online
„
Backup of the main application
„
Manual & Automatic
„
Uses Shadowing
„
Advanced programmable option
SYS 600
- 33 -
„
Base System Object Navigator
Online handling of base system objects
„
View
„
Create
„
Modify
- 34 -
SYS 600
System Configuration Tool
„
DNP data point editor
„
General ASCII (ADEMCO) Communication Line and
Stations Configuration
„
ASCII Printer Communication Line Configuration
SYS 600
„
„
- 35 -
„
DMS integration
Integrated user interface
„
Pop-up menu to trace feeders, locate objects on map etc.
„
Easy way to open single line diagrams from the network map
„
Network data from DMS available in process graphics
„
Integrated login
Single data entry
„
The data on the single line diagrams are reused
„
Layout, objects and connectivity are used in DMS
Harmonization
„
Look and feel
„
Colors
„
Symbol presentation
© ABB Substation Automation - 36 1/14/2005
MicroSCADA Pro
DMS 600 *4.0
(Opera technology)
DMS 600
„
DMS 600 *4.0 is direct successor
to Open++ Opera 3.3
„
- 37 -
„
MicroSCADA Pro DMS 600 *4.0
Existing installation can be updated
directly using installation program
DMS 600 *4.0 belongs to
MicroSCADA Pro product family
„
A standard option to any SCADA and
SA system
„
Consistent product name (ref. SYS
600, LIB 500)
„
Integrated and consistent ordering tool
and procedures
DMS 600
„
Harmonized and integrated with MicroSCADA Pro SYS
600 *9.0
„
Common Windows look and feel
„
- 38 -
MicroSCADA Pro DMS 600 *4.0
New process graphics, new list applications
„
User interface well integrated
„
Microsoft component technology (COM and OPC) used. Same
technology used also to third party software integration
(Microsoft Office).
DMS 600
„
- 39 -
„
Changes in license structure
In DMS 600 there is one basic product and options can be
selected on top of that. In Opera 3.3 additional options where
available only on top of Opera standard.
Opera LT (light)
DMS 600 (Base)
Opera standard
+ General extensions
+ other options
+ other options
New license modules (in addition to General extensions)
„
Outage info using HTML for intra/internet
„
Outage info using telephone answering machine
„
Outage info using SMS messages
„
GPS data for field crew location and network editing
- 40 -
DMS 600
Unchanged license modules
„
Network Analysis
„
Extended load modeling
„
Operations planning
„
Reconfiguration
„
Fault location
„
Outage reporting and statistics
„
Restoration support
„
Automatic fault isolation and restoration
„
Low voltage networks
„
Extended data management
DMS 600
„
„
- 41 -
„
DMS 600 - SYS 600 Integration
User interface integrated (DMS 600 base)
„
Pop-up menu to trace feeders, locate objects on map etc.
„
Easy way to open single line diagrams from the network map
„
Control dialogs for switches opened directly from network map
„
Feeder data from DMS available in process graphics for
feeding CBs and line indicators without using DMS in the user
session
„
Integrated login and logoff (SYS 600 ->DMS 600)
Single data entry
„
The data on the single line diagrams are reused
„
Layout, objects and connectivity are used in DMS
Harmonization
„
Windows look and feel
„
Colors
„
Symbol presentation
DMS 600
„
„
The society requires information of
distribution quality
„
Exact information of outage situation
and forecasts
„
For media, customers and own
organization
The authorities and regulators
require statistics and information
„
„
Key figures to evaluate operational
quality and efficiency
New laws
„
- 42 -
New requirements for DisCos
In Finland compensation for long
outages to all customers
- 43 -
DMS 600
Outage information in internet/intranet
„
Information to internal management and
external parties like media
„
History of the situation is stored to study
the chosen actions
„
DMS 600 creates automatically
„
html-document for intra- and internet
„
MS Word-documents stored for later
studies
- 44 -
DMS 600
Outage information using SMS messages
„
Automatic GSM SMS-messages
when a fault occurs on a feeder
„
Opera queries from database those
customers telephone numbers that
are fed by the faulted feeder
„
Can be used to inform maintenance
outages etc.
„
Uses a GSM modem and modem
driver installed in MicroSCADA
server
DMS 600
„
Recorded messages for each feeder
„
Messages can be generated automatically
„
Calling customers can try reach a person or leave a voice message
„
„
- 45 -
Outage information by telephone
if recorded messages do not give enough information or customer has vital
information to give
The voice messages are sent as email to the operators
DMS 600
„
GPS support
GPS for field crew location
„
Coordinates from GPS can be used
in real-time
„
Supports WGS84 and local Map
Datums
„
Continuous location of own
position with map panning in
moving vehicles
„
GPS coordinates used in network
editing
„
Way-points can be stored to GPS
device
„
NMEA-0183 serial communication
standard is used to transfer points to
Opera so that network can be
updated accurately
- 46 -
NMEA = National Marine Electronics Association
DMS 600
- 47 -
„
New features in DMS 600 base
Enhanced network editing
„
Copy-paste
„
Moving and deleting large parts of network
„
Simulation of historical events
„
Trace coloring remains on screen while zooming and
panning
„
Findings to show added information on network map
(in parallel with existing operator notes)
„
Print-out of several lists
„
New way to zoom out desired amount
- 48 -
DMS 600
Other new features
„
Impedance-based fault distance
calculation (Fault location)
„
Setting of hour of the year (date and
time) (Network analysis)
„
Blinking symbols when object having
an unacknowledged alarm in SYS
600 (Alarms in module general
extensions)
© ABB Substation Automation - 49 1/14/2005
LIB 5xx with
MicroSCADA Pro
- 50 -
LIB 500/510
LIBs for SYS 600 *9.0
„
LIB 500 *4.0
„
LIB 510 *4.1
„
LIB 520 *4.0.4
„
LIB 530 *4.0.4
„
LIB 542 *4.0.4
„
LIB 500 *4.0.5 for SYS 500 *8.4.5
LIB 500/510
- 51 -
„
New features
News in 4.0.5 and 4.1 :
„
REX 521 rev. E support
„
Possibility to use the Relay Setting Tool and DR-Collector Tool
together with IEC101/SPA and IEC104/SPA gateways. No
support for the Power Quality Monitoring tool and Event editor
Tool.
LIB 500/510
„
News in 4.1 only
„
- 52 -
New features
IEC 61850 support
„
Pictures (generic)
„
DB (generic)
„
Relay setting (SPA over 61850)
„
Disturbance recorder (SPA over 61850)
FIPTUA/SAP
MicroSCADA Pro communication
FIPTMV/DA
© ABB Substation Automation - 53 1/14/2005
COM 500 *4.1
COM 500
„
Well known substation gateway COM500 – new
revision!!
„
Main changes since *4.0
„
New Base System SYS 600 9.0 Integrated
„
„
„
„
Including MicroSCADA Data Access OPC Server
Communication Software
„
- 54 -
New Features
PC-NET protocol extensions included
Signal Routing
„
Support for IEC 61850 process devices
„
2000 alarm groups now supported
Tools
„
Updated tools from the SYS 600 9.0 integrated
„
Cross-Reference file converter
LIB 500/510
„
Protocol improvements (also in SYS600)
„
DNP V3.00 Subset Level 3
„
- 55 -
„
New Features
Both master & slave
„
Faster Interrogation with SQ=1 Packing Style in IEC60870-5101
„
Enhanced process communication
„
Improved Modbus (RTU/TCP) Master for multidrop
„
Improved DNP3.0 Master for multidrop
New protocol support in SYS600
„
IEC61850-8-1 as OPC server (see later)
„
P214, ported from DCP-NET
„
General ASCII, ported from DCP-NET
„
RCOM, ported from DCP-NET
LIB 500/510
- 56 -
„
New Features
Miscellaneous:
„
Increased Alarm Group count (from 255 to 2000)
„
New Options for Trip Signal Handling
„
Direct IEC commands for Secured Controls in process direction
„
More command parameters for REC 561
LIB 500/510
„
Following SYS 600 9.0 Tools Integrated
„
Object Navigator with New Functionality
„
Install Standard Functions
„
New Navigation Schemes
„
- 57 -
Tools
„
for Process Objects, Data Objects
„
for Command Procedures
„
and for Free Type Process Objects
Export and Import Application Objects
„
System Configuration tool with New Functionality
„
New Base System Object Navigator tool
„
New Online Backup tool
„
New SCIL Database tool
„
New Event Conversion tool
LIB 500/510
- 58 -
„
Tools
Cross reference file converter
„
Convert the cross reference information from the tabular sheet file (e.g.
Excel files) to .XRF format
„
XRF format file is then imported into Cross-References tool
„
Supports at the moment monitoring direction cross references only
FIPTUA/SAP
© ABB Substation Automation - 59 1/14/2005
FIPTMV/DA
MicroSCADA Pro
IEC61850 support
IEC61850-8-1
„
IEC61850-8-1 support in MicroSCADA Pro
„
„
- 60 -
IEC61850-8-1 support
Newest, most exciting protocol in Substation Automation
supported in
„
SYS600 *9.0
„
COM500 *4.1
Common implementation for all products above
„
Implemented as OPC DA server
„
SYS600 and COM500 will use MicroSCADA OPC DA client
„
CET is always used as the configuration tool
IEC61850-8-1
„
IEC61850-8-1 client OPC Server
IEC61850-8-1 OPC server features
„
MMS protocol stack implemention
„
Read / Write Variable Data, Buffered / Unbuffered Reporting -> dynamically updated
process image
„
Commands
„
Special handling for Setting Group control
„
„
Namespace corresponding to IEC61850-7-x data model
„
Transparent SPA over TCP/IP for IED tool connectivity
„
Supported also in SPA-ZC40x and in Swiss RE.316
„
Can be used for tool remote access – as far as TCP/IP connection is available
„
Protocol diagnostics published also in OPC namespace
„
Time synchronization: SNTP client
„
„
Support several servers for redundancy
CET, Communication Engineering Tool
„
SCL device descriptions import for signal engineering
„
- 61 -
XML based access using XSAT protocol
Mandatory for IEDs supporting IEC61850
IEC61850-8-1
IEC61850-8-1 client OPC Server
- 62 -
„
CET
IEC61850-8-1
„
IEC61850-8-1 – SYS600
New features for IEC61850-8-1 protocol support in SYS600/LIB500
„
Protocol implemented as IEC61850-8-1 client OPC server
„
SYS 600
„
Object navigator
„
„
LIB 510 *4.1
„
„
- 63 -
Support of IEC61850 process object types in single-line-diagram picture
functions
COM 500 *4.1
„
„
Support of creating LIB510 process database for generic IEC61850
devices
Support of IEC61850 process object types
MicroSCADA OPC DA client *2.1
„
A stand-alone MicroSCADA node behind TCP/IP
„
Easier mapping between OPC namespace and process database
IEC61850-8-1
IEC61850 and SYS600
„
MicroSCADA Pro
SYS600
„
„
SYS600
- 64 -
OPC
Server
MS OPC DA
client
Process
Database
ACP
MicroSCADA
ACP TCP/IP
OPC Client
IEC61850-8-1 OPC Server
Ethernet / IEC61850-8-1
SYS 600 *9.0
„
OPC DA Client *2.1
„
IEC61850-8-1 client OPC
server
LIB 510 *4.1 or COM500 *4.1