Untitled - VTS Group
Transcription
Untitled - VTS Group
2016 RELIABLE AND TIGHT CONSTRUCTION TOP QUALITY COMPONENTS INTELLIGENT CONTROL SYSTEMS SAFETY OF USE STRUCTURE AZ 150 ALUZINC SHEET ALUMINIUM COLUMNS AS STANDARD FOR ALL TYPES OF UNITS RESISTANCE TO CORROSION 3000 2412 Number of hours 2500 VENTUS AHU new coating resistance 2000 1500 1000 500 0 162 Galvanised 20 Mu Z275 Aluzinc 20 Mu AZ150 Z PROFILE C PROFILE VS 21-150 VS 180-650 GALVANIZED STEEL SUPPORT AS STANDARD FOR ALL TYPES OF UNITS Salt spray test according to ASTM B-117 CASING SKIN FAN SECTION CAGE FRAME STRUCTURAL COLUMNS »» metal sheet thickness increased by 20% »» increased rigidity and durability of the AHU structure »» low absorption of heat radiation and UV »» increased resistance to weather conditions »» increased longitudinal stiffness of the structure »» easier sections assembly »» easier transport »» greater profile resistance to deflection »» thermal breaks on the mullion as standard »» high resistance to weather conditions and UV rays TIGHTNESS SMART HINGE SYSTEM VTS PATENTED PROPRIETARY SOLUTION THERMAL BREAK ADDITIONAL COLUMN SEALING LABYRINTH SEALING ADDITIONAL SEALING FINS INSPECTION PANELS EQUIPPED WITH THE OPEN / CLOSE SMART SYSTEM AND NEW PROTECTIVE CORNERS ALUMINIUM STRUCTURAL COLUMNS WITH AN ADDITIONAL SEALING FIN AND A THERMAL BREAK »» easy to use, enabling quick opening and closing of the inspection panel »» smart hinge - prevents seal breaking when the panel is opened (VTS proprietary and patented solution) »» improved ergonomics with an integrated handle and hinge function »» reduced risk of panel damage »» thermal breake as standard - ensures no condensation outside the AHU »» the fin ensures labyrinth sealing - currently the most effective solution on the market, mainly used in laboratory equipment »» original solution consisting in the use of symmetrical channel tension filled with a sealing compound, which provides 100% tightness of the connection between the column and construction structure CONTROLS NEW FEATURES MAIN and LX HMI MEASUREMENT AND CONTROL OF THE CONSTANT AIR VOLUME »» adjustment of the preset constant air volume under changing flow resistance compensation of changing internal resistance of the AHU (e.g. with varying degrees of air filter dirt, different setpoint of the mixing box, etc.) »» adjustment of the fan power to the current needs of the installation »» immediate readiness of the AHU to work with the required performance immediately after installation CONSTANT PRESSURE CONTROL WITH VARIABLE AIR VOLUME »» control of constant, preset air pressure at variable volume (efficiency change is carried out through the air distribution system – e.g. VAV controllers) SMART HMI ELECTRIC HEATER CONTROL »» smooth control system that adjusts instantaneous power to the current demand HUMIDITY CONTROL »» automatic reduction of the amount of outside air (keeping the CO2 concentration below the set value) »» optimisation of consumption of heat and electricity »» control over air humidifying - both evaporative and steam »» supports control the drying process »» adaptation to the special needs of the building »» protection in case of failure of the first engine 1 source SOURCE OF HEATING /COOLING 2 sources ULTRA+ SMART MAIN LX • • • • • • • • • 3 sources • 4 and more sources CO2 CONTROL OF VS21 – 150 BACKUP ENGINES NEW RANGE OF CONTROLLERS COMMUNICATION WITH MASTER SYSTEM FUNCTIONS MIXING BOX CONTROL »» smooth control of the mixing box, external signal or as in the CO2 control function, etc. »» optimization of the ventilation air to save energy TCP/IP Modbus • • WebServer • • BacNET • • Dual methode of heating coil freeze protection (low limit thermostat on the air and water side) • • • Energy recovery systems frost protection (temperature sensor downstreem energy recovery section) • • • Measurement and control of the constant air volume (CAV) • • Measurement and maintennance of air volume based on system required pressure (VAV) • • Control of the concentration of carbon dioxide in the air • • Air humidity control • • Pre-heater control for extreme low temperatures (maximization of the energy recovery performance) SOURCES OF HEATING/COOLING »»Primary heater »»Primary cooler »»The recovery (plate heat exchanger or a rotary exchanger, glycol system) »»Mixing box »»Primary heater (before recovery of heat), electric/water »»Reheat coil (mainly used for drying) • SAFETY OF USE PANEL CLOSED Contact closed – fan start permitted PANEL OPENED Contact Reed switch PLUG fan section Contact open – fan start prohibited Contact Contact Reed switch Reed switch PLUG fan section HANDLE OPEN PROTECTION FAN SAFETY BARRIER PLUG fan section REED SWITCH Contact Reed switch »» increased safety against accidental opening of the fan section »» protection against fan in-operation PLUG fan section »» electronic stop of the motor when the panel is opened Contact VTS Group Headquarters VTS Sp. z o.o. Olivia Tower, Al. Grunwaldzka 472 A 80-309 Gdańsk, Poland tel: +48 58 628 13 54 fax: +48 58 628 13 22 e-mail: [email protected] www.vtsgroup.com