ingenius - Integrated Scientific Solutions Inc.

Transcription

ingenius - Integrated Scientific Solutions Inc.
INGENIUS
Low cost gel
documentation
and analysis
S Y N G E N E
A DIVISION OF THE SYNOPTICS GROUP
INGENIUS
When simplicity and budget matter.
The InGenius range of gel documentation
and analysis systems are compact, easy
to use and offer an affordable route to gel
capture and analysis. Using many of the
features found on the higher specification
Syngene systems, the InGenius is available
in two versions.
InGenius applications
Both models use the same innovative
darkroom. Camera choice enables pixel
resolution up to 5.5 million pixels.
They are cost effective because they
DNA
With InGenius you can use the UV
transilluminator to capture images
of DNA gels stained with Ethidium
Bromide, SYBR® dyes and many
other probes
offer a range of flexible options.
Each system includes GeneTools analysis
software.
Choose from two configurations:
Blue light applications
The blue light converter allows
you to view some fluorescent stains
with better clarity and with less
gel damage
• InGenius L - entry level
• InGenius LHR - extended resolution
Visible light applications
With the transmitted visible light
or using the epi white light facility,
InGenius can be used to view gels
which have been stained with silver
stain and Coomassie blue. You can
also view tissues, slides and films
AutoRads
InGenius features a mega resolution
camera which is ideal for capturing
images requiring high detail. This is
especially true when looking for
‘separation’ between bands and
spots. Capturing high quality images
of Autorads is one of the strengths
of InGenius
Spot blots
Capturing and analysing spot blots
is another very simple application for
InGenius and GeneTools software
InGenius system
CAPTURE, STORE AND
MANIPULATE IMAGES
WITH GENESNAP
COMPUTER
Image acquisition with a
single button
CAMERA
Auto exposure/manual
exposure/series capture
Extended dynamic range up
to 65,536 grey levels
Neutral fielding for correction
of uneven background
illumination
Effective pixel control - for
extending image resolution
Toolbox - annotation/
sharpening/inverting
USB2 connection
CCD digital camera
• 1.2m effective pixels
(InGenius L)
• 5.5m effective pixels
(InGenius LHR)
LENS
Superior zoom lens for
exceptional image quality
FILTER DRAWER
Use a range of filters
for extensive choice of
fluorescent applications*
Saturation control - see which
areas of the image are over
exposed
SAFETY SWITCH
Focus indicator - view the
optimum focus point
Protects from accidental UV
exposure when opening door
INTERNAL WHITE LIGHT
ANALYSE, DOCUMENT
AND QUANTIFY GELS
WITH GENETOOLS
1D analysis at the ‘click’ of
a button
For sample positioning and
focusing
TRANSILLUMINATOR
For UV and transmitted
visible/blue light applications
MW/BP calibrations
SLIDING DOOR
Quantity calibrations
Space saving sliding door
Spot blot/colony plate analysis
Band matching functions
*see the on-line Syngene
database for details
INGENIUS
When simplicity and budget matter.
The InGenius range of gel documentation
and analysis systems are compact, easy
to use and offer an affordable route to
gel capture and analysis.
InGenius specification
InGenius L
InGenius LHR
Resolution
(effective pixels)
1.2m pixels
5.5m pixels
Bit depth
12 bit/16 bit
12 bit/16 bit
4,096/65,536
4,096/65,536
3.6/4.8
3.6/4.8
Yes
Yes
Visible light NovaGlo
converter
Option
Yes
Blue light converter
Option
Option
White Epi overhead
Yes
Yes
Dual UV Epi*
Option
Option
Blue Epi*
Option
Option
GeneDirectory
Option
Option
Camera
Greyscales
Dynamic range
Illumination
UV transilluminator
20 x 20
*Factory fitted option
S Y N G E N E
A DIVISION OF THE SYNOPTICS GROUP
Ordering details/options
IG/L 1.2 million
effective pixels
(includes 20 x 20cm
302nm transilluminator)
IG/LHR 5.5 million
effective pixels
(includes 20 x 20cm
302nm transilluminator)
Options
GVM30D
transilluminator
Wavelength 302nm
Filter area 20 x 30cm
GVM25/30D
transilluminator
Wavelength 302nm
Filter area 25 x 30cm
GVLM20D
transilluminator
Wavelength 302/365nm
Filter area 20 x 20cm
GVLM30D
transilluminator
Wavelength 302/365nm
Filter area 20 x 30cm
GVLM25/30D
transilluminator
Wavelength 302/365nm
Filter area 25 x 30cm
CONVERTBLUE
UV to blue light converter
CONVERT-NOVAGLO2
UV to visible light
converter
EPI-BL/IG*
Epi Blue light kit with
white light
EPI-BL-UV/IG*
Epi Blue light kit with UV
light (365 & 254nm)
EPIKIT-UV/IG*
Epi UV upgrade kit with
white light (365 & 254nm)
FILTSG-58/IGF
SYBR Gold filter
FILTSP-58
Short Pass filter
FILTLP-58
Long Pass filter
P93DW
Thermal printer digital,
USB
Syngene Europe and
International Headquarters:
Beacon House Nuffield Road
Cambridge CB4 1TF UK
Tel: +44 (0)1223 727123
Fax: +44 (0)1223 727101
email: [email protected]
Syngene USA Headquarters:
5108 Pegasus Court Suite M
Frederick MD 21704 USA
Tel: 800-686-4407/301-662-2863
Fax: 301-631-3977
email: [email protected]
Website: www.syngene.com
G.0051.A1
All trademarks acknowledged
K65HM
Thermal paper matt
K91HG
Thermal paper gloss
*Factory fitted option
S Y N G E N E
A DIVISION OF THE SYNOPTICS GROUP
InGenius features & benefits
Features
Benefits
Small and compact darkroom with sliding door
Small footprint taking up minimal laboratory bench space
Camera choice enables pixel resolution up to
5.5 million pixels
Good quality images
16 bit images (0 - 65,535 grey levels dynamic range)
Precise quantitation
Filter drawer
Capable of viewing a wide range of different fluorophores
UV to visible light converter screen
Easy imaging of protein gels, autoradiographs
and colony plates
GeneTools analysis software
Saves time by automating analysis of gels,
colony plates & blots
Connect to any PC
Use a computer of your choice
These are just some of the
applications that can be used with
InGenius. The Syngene Applications
and Support Department is always
ready to discuss your particular
application samples and how they
can be imaged using InGenius.
The Syngene website contains
further technical notes and FAQ’s
covering the use of all Syngene gel
documentation systems.
Further details can be found at
www.syngene.com
Over 50,000 scientists
world-wide in pharmaceutical and
biotech companies, as well as
academic and government
institutions, have chosen Syngene as
their expert imaging partner. If you’d
like to find out why, please contact
us or one of our dealers for more
information and a demonstration of
the revolutionary InGenius
Syngene Europe and
International Headquarters:
Beacon House Nuffield Road
Cambridge CB4 1TF UK
Tel: +44 (0)1223 727123
Fax: +44 (0)1223 727101
email: [email protected]
Syngene USA Headquarters:
5108 Pegasus Court Suite M
Frederick MD 21704 USA
Tel: 800-686-4407/301-662-2863
Fax: 301-631-3977
email: [email protected]
Website: www.syngene.com
G.0051.A
All trademarks acknowledged