NOTES
General Notes
This drawing illustrates design intent only and should be
read in conjunction with:- All relevant Specialist Subcontractor drawings.
- All relevant sections of N.B.S.
- Structural engineers drawings & specification.
- Mechanical engineers drawings & specification.
- Electrical engineers drawings & specification.
- Manufacturers drawings and specifications
where applicable, and constructed in strict
accordance with instructions and recommendations.
- All construction must conform to all relevant British
Standards and the building regulations.
- All areas and dimensions are to be checked on site
prior to manufacture or construction.
A
Metal composite roof system
Colour: RAL 180 40 05 Merlin
Grey
B
C
3457
D
7089
Metal Composite roof system
Colour: RAL 180 40 05 (Merlin Grey)
2no skylight windows
PPC metal fascias & soffits
Colour: RAL 180 40 05
Merlin Grey
5851
Metal composite panels
Colour: RAL 9007
ANY DISCREPANCIES ARE TO BE REPORTED TO THE ARCHITECT
BEFORE ANY WORK COMMENCES
THIS DRAWING SHALL NOT BE SCALED TO ASCERTAIN ANY
DIMENSIONS WORK TO FIGURED DIMS ONLY
THIS DRAWING SHALL NOT BE REPRODUCED WITHOUT EXPRESS
WRITTEN PERMISSION FROM AFL LTD.
LEGEND
IP65 external lighting, round.
Type and mounting height TBC
IP65 external lighting, rectangular.
Type and mounting height TBC
Approximate setting out
positions only. Subject to
confirmation
E
7089
ALL DIMENSIONS AND LEVELS ARE TO BE CHECKED ON SITE
Metal composite panels
Colour: RAL 9007
Eaves 5.958m
Eaves 5.555m
C12 17.05.16 PLANNING VARIATION
JS
Ridge 3.584m
New link- See drawing AA-20-006
200
Eaves 3.213m
C11 26.04.16 Detail added to windows and doors and
RM
mullion positions adjusted, structural opening
positions unchanged. Windows to link corridor height reduced and levels staggered as
requested by Prosol 19.04.16. Roof detail and
levels updated. RAL references to Kingspan
roof, windows, rwp's and louvres amended.
C10 31.03.16Drawing updated as per P&W email comments
TE
11.03.16 to include: Blue brick reference
amended, Indicative service link added,
Lightning conductors removed, Rebound room
exhaust louvre relocated to east elevation &
lighting unit relocated to suit.
C9
XD3
Exhaust louvre for
Rebound Room
RAL 180 40 05
(Merlin Grey)
2110
XD4
300
09-03-16
Staffordshire Slate Blue Smooth brick added
RL
to Link Corridor following contractor site
meeting comments on 09-03-16.
01-03-16
Levels adjusted to suit current landscape
NP
information, gradient approach to doors
indicated, brick hatch corrected, text size &
general hatch / graphics rationalized, lighting
clarified.
16-02-16
RWP, vents and flue location amended.
RL
External lighting added following
co-ordination with M&E information. Window
sizes reduced by 225mm
21/01/16
Eaves and ridge line increased on GL-A at
RL
GL-2 to GL-6. Flue addded
15/12/15
Ridge line updated to GL-2
RL
15/12/15
Issue for co-ordination
RL
C8
572 approx. dimension
4510 approx. dimension
685 approx. dimension
235 approx. dimension
3160 approx. dimension
C7
FFL 0.450m
-0.180m
rwp
Colour: RAL 180 40 05
(Merlin Grey)
Facing Bricks
Slate Blue Smooth
with a neutral coloured mortar
rwp
Facing Bricks
Leicester Multi Cream Stock
with a neutral coloured mortar
7415
C6
rwp
PPC Aluminium Windows
Frame Colour: RAL 180 40 05
(Merlin Grey)
Radon vents
Proposed location of
A/C condenser unit set
min. 2100 above FFL.
Through colour render
system Colour: Powder
Blue RAL 210 80 10
rwp
C5
C4
East Elevation
C3
06/02/15
Level of building raised by 450mm as per
SK
Client's request
06/11/14
Location of condenser unit indicated
SK
19/09/14
Construction
LP
02/07/14
Planning Issue
LP
10.04.2014
AJS Planning Issue
C2
C1
P2
P1
rev
date/intls
description
project
Proposed Extension
location
Burnley
client
6
5
3
4
1360
3582
Metal composite panels
Colour: RAL 9007 (Obsidian)
PPC metal fascias & soffits
Colour: RAL 180 40 05
(Merlin Grey)
2
3750
1
4300
Burnley Campus
6450
Eaves 5.958m
Eaves 5.555m
AFL Architects
1st Floor
St Georges House
56 Peter Street
Manchester UK
M2 3NQ
GRP Rooflight
PPC metal fascias & soffits
Colour: RAL 180 40 05
(Merlin Grey)
Ridge 4.310m
t: +44(0)161 236 6263
f: +44(0)161 236 6484
Boiler
Flues
w: www.afl-uk.com
e: [email protected]
London office
t: +44 (0)20 7831 8877
Eaves 3.725m
Eaves 3.213m
key plan
Indicative service link
Existing covered
walkway / service duct
W10
797 approx. dimension
North Elevation
1360 approx. dimension
Facing Bricks
Slate Blue Smooth
with a neutral coloured mortar
1810 approx. dimension
Through colour render system
Colour: Powder Blue
RAL 210 80 10
W9
2035 approx. dimension
Radon vents
W8
XD5
W7
PPC Aluminium Windows
Frame Colour: RAL 180 40 05
(Merlin Grey)
FFL 0.450m
Facing Bricks
Leicester Multi Cream Stock
with a neutral coloured mortar
Site determined levels
(locally) beyond gradient
edge, by site contractor.
FFL varies - existing walkway
FFL 0.000m
drawing title
HOLLY GROVE
PROPOSED GA ELEVATIONS
SHEET 1 OF 2
dwg purpose
PLANNING
drawn JS
checked NP
@ sheet size A1
rev date
17/05/16
147104
AE-20-001
C12
job number
drawing number
revision
scale
Please note that FFL 0.000 refers to the the Existing School FFL
1:50