ae-20-001 rev c12 sheet 1 of 2 proposed
Transcription
ae-20-001 rev c12 sheet 1 of 2 proposed
NOTES General Notes This drawing illustrates design intent only and should be read in conjunction with:- All relevant Specialist Subcontractor drawings. - All relevant sections of N.B.S. - Structural engineers drawings & specification. - Mechanical engineers drawings & specification. - Electrical engineers drawings & specification. - Manufacturers drawings and specifications where applicable, and constructed in strict accordance with instructions and recommendations. - All construction must conform to all relevant British Standards and the building regulations. - All areas and dimensions are to be checked on site prior to manufacture or construction. A Metal composite roof system Colour: RAL 180 40 05 Merlin Grey B C 3457 D 7089 Metal Composite roof system Colour: RAL 180 40 05 (Merlin Grey) 2no skylight windows PPC metal fascias & soffits Colour: RAL 180 40 05 Merlin Grey 5851 Metal composite panels Colour: RAL 9007 ANY DISCREPANCIES ARE TO BE REPORTED TO THE ARCHITECT BEFORE ANY WORK COMMENCES THIS DRAWING SHALL NOT BE SCALED TO ASCERTAIN ANY DIMENSIONS WORK TO FIGURED DIMS ONLY THIS DRAWING SHALL NOT BE REPRODUCED WITHOUT EXPRESS WRITTEN PERMISSION FROM AFL LTD. LEGEND IP65 external lighting, round. Type and mounting height TBC IP65 external lighting, rectangular. Type and mounting height TBC Approximate setting out positions only. Subject to confirmation E 7089 ALL DIMENSIONS AND LEVELS ARE TO BE CHECKED ON SITE Metal composite panels Colour: RAL 9007 Eaves 5.958m Eaves 5.555m C12 17.05.16 PLANNING VARIATION JS Ridge 3.584m New link- See drawing AA-20-006 200 Eaves 3.213m C11 26.04.16 Detail added to windows and doors and RM mullion positions adjusted, structural opening positions unchanged. Windows to link corridor height reduced and levels staggered as requested by Prosol 19.04.16. Roof detail and levels updated. RAL references to Kingspan roof, windows, rwp's and louvres amended. C10 31.03.16Drawing updated as per P&W email comments TE 11.03.16 to include: Blue brick reference amended, Indicative service link added, Lightning conductors removed, Rebound room exhaust louvre relocated to east elevation & lighting unit relocated to suit. C9 XD3 Exhaust louvre for Rebound Room RAL 180 40 05 (Merlin Grey) 2110 XD4 300 09-03-16 Staffordshire Slate Blue Smooth brick added RL to Link Corridor following contractor site meeting comments on 09-03-16. 01-03-16 Levels adjusted to suit current landscape NP information, gradient approach to doors indicated, brick hatch corrected, text size & general hatch / graphics rationalized, lighting clarified. 16-02-16 RWP, vents and flue location amended. RL External lighting added following co-ordination with M&E information. Window sizes reduced by 225mm 21/01/16 Eaves and ridge line increased on GL-A at RL GL-2 to GL-6. Flue addded 15/12/15 Ridge line updated to GL-2 RL 15/12/15 Issue for co-ordination RL C8 572 approx. dimension 4510 approx. dimension 685 approx. dimension 235 approx. dimension 3160 approx. dimension C7 FFL 0.450m -0.180m rwp Colour: RAL 180 40 05 (Merlin Grey) Facing Bricks Slate Blue Smooth with a neutral coloured mortar rwp Facing Bricks Leicester Multi Cream Stock with a neutral coloured mortar 7415 C6 rwp PPC Aluminium Windows Frame Colour: RAL 180 40 05 (Merlin Grey) Radon vents Proposed location of A/C condenser unit set min. 2100 above FFL. Through colour render system Colour: Powder Blue RAL 210 80 10 rwp C5 C4 East Elevation C3 06/02/15 Level of building raised by 450mm as per SK Client's request 06/11/14 Location of condenser unit indicated SK 19/09/14 Construction LP 02/07/14 Planning Issue LP 10.04.2014 AJS Planning Issue C2 C1 P2 P1 rev date/intls description project Proposed Extension location Burnley client 6 5 3 4 1360 3582 Metal composite panels Colour: RAL 9007 (Obsidian) PPC metal fascias & soffits Colour: RAL 180 40 05 (Merlin Grey) 2 3750 1 4300 Burnley Campus 6450 Eaves 5.958m Eaves 5.555m AFL Architects 1st Floor St Georges House 56 Peter Street Manchester UK M2 3NQ GRP Rooflight PPC metal fascias & soffits Colour: RAL 180 40 05 (Merlin Grey) Ridge 4.310m t: +44(0)161 236 6263 f: +44(0)161 236 6484 Boiler Flues w: www.afl-uk.com e: [email protected] London office t: +44 (0)20 7831 8877 Eaves 3.725m Eaves 3.213m key plan Indicative service link Existing covered walkway / service duct W10 797 approx. dimension North Elevation 1360 approx. dimension Facing Bricks Slate Blue Smooth with a neutral coloured mortar 1810 approx. dimension Through colour render system Colour: Powder Blue RAL 210 80 10 W9 2035 approx. dimension Radon vents W8 XD5 W7 PPC Aluminium Windows Frame Colour: RAL 180 40 05 (Merlin Grey) FFL 0.450m Facing Bricks Leicester Multi Cream Stock with a neutral coloured mortar Site determined levels (locally) beyond gradient edge, by site contractor. FFL varies - existing walkway FFL 0.000m drawing title HOLLY GROVE PROPOSED GA ELEVATIONS SHEET 1 OF 2 dwg purpose PLANNING drawn JS checked NP @ sheet size A1 rev date 17/05/16 147104 AE-20-001 C12 job number drawing number revision scale Please note that FFL 0.000 refers to the the Existing School FFL 1:50