ILUMEN PID SOLUTION
Transcription
ILUMEN PID SOLUTION
ILUMEN PID SOLUTION ILUMEN PID BOX & ILUMEN PID CONTROL BOX INSTALLATION MANUAL Ilumen PID Box and Ilumen PID Control Box – Version 1.0 Ilumen 1 TABLE OF CONTENT 1 Information on this manual .................................................................................................................................4 2 3 4 5 6 7 1.1 Validity ................................................................................................................................................................4 1.2 Target Group.....................................................................................................................................................4 1.3 Additional information .................................................................................................................................4 Safety .............................................................................................................................................................................4 2.1 Appropriate usage ..........................................................................................................................................4 2.2 Qualifications of skilled persons...............................................................................................................4 2.3 Safety precautions ..........................................................................................................................................5 2.3.1 Electric shock ..........................................................................................................................................5 2.3.2 Electrostatic discharge........................................................................................................................5 Scope of delivery.......................................................................................................................................................5 3.1.1 Ilumen PID Box ......................................................................................................................................5 3.1.2 Ilumen PID Control Box ......................................................................................................................5 Product description .................................................................................................................................................5 4.1 Ilumen PID Control Box................................................................................................................................5 4.2 Ilumen PID Box ................................................................................................................................................7 Mounting ......................................................................................................................................................................7 5.1 Mounting location requirements for theIlumen PID Control Box ..............................................7 5.2 Mounting location requirement for the Ilumen PID Box................................................................7 5.3 Mounting the Ilumen PID Solution ..........................................................................................................8 5.3.1 The Ilumen PID Control Box .............................................................................................................8 5.3.2 The Ilumen PID Box..............................................................................................................................8 Electrical connection...............................................................................................................................................8 6.1 AC connection...................................................................................................................................................8 6.2 Earth connection .............................................................................................................................................8 6.3 Ilumen PID Control Box to Ilumen PID Box connection .................................................................9 6.4 Solar array and inverter (MPPT) to Ilumen PID Box connections .............................................9 6.5 Ilumen PID Box series connection ........................................................................................................ 10 Commissioning ....................................................................................................................................................... 10 7.1 Check ................................................................................................................................................................. 10 7.2 Starting up the Ilumen PID Solution .................................................................................................... 11 8 Installation summary ........................................................................................................................................... 11 9 Decommissioning the Ilumen PID Solution ................................................................................................ 13 Installation Manual Ilumen PID Box & Ilumen PID Control Box 2 Ilumen 10 Troubleshooting ................................................................................................................................................ 13 10.1 No GPRS connection ................................................................................................................................... 13 10.2 No good PID regeneration ........................................................................................................................ 13 11 Technical data .................................................................................................................................................... 14 12 Contact .................................................................................................................................................................. 15 Installation Manual Ilumen PID Box & Ilumen PID Control Box 3 Ilumen 1 INFORMATION ON THIS MANUAL This manual contains instructions on how to install the Ilumen PID Box and the Ilumen PID Control Box. 1.1 VALIDITY This manual is valid for Ilumen PID Box v1.0 and Ilumen PID Control Box v1.0 1.2 TARGET GROUP This manual is intended for skilled persons. Only qualified persons with the appropriate skills are allowed to perform the tasks set forth in this manual. 1.3 ADDITIONAL INFORMATION Links to additional information can be found at www.ilumen.be Ilumen PID solution data sheet What is PID? PID checker 2 SAFETY 2.1 APPROPRIATE USAGE The Ilumen PID Solution applies a voltage to PV modules in reference to earth. The Solution may only be switched on when the installation is completed as described in this manual. Before installing the Ilumen PID Solution, ensure that the permitted operating range of each component is maintained at all times. Before using the Ilumen PID Solution you have to obtain the appropriate approval from the manufacturer of the PV modules. Any applications other than those described here shall be considered contrary to the appropriate usage. Alternative use or modification of the Ilumen PID Solution will void warranty claims and operation permit. 2.2 QUALIFICATIONS OF SKILLED PERSONS The work described in this document must be performed by skilled persons only. Skilled persons must have the following qualifications: Knowledge of how an inverter works and is operated Training in how to deal with the dangers and risks involved in installing and operating electrical devices and plants Training in the installation and commissioning of electrical devices and plants Installation Manual Ilumen PID Box & Ilumen PID Control Box 4 Ilumen Knowledge of all applicable standards and directives Knowledge and observance of this document and all safety precautions 2.3 SAFETY PRECAUTIONS 2.3.1 ELECTRIC SHOCK When the Ilumen PID Solution is in operation, voltage will be present. Prior to maintenance work on the PV plant switch off the Ilumen PID Control Box. When you want to change the arrangement of the Ilumen PID Solution or want to add new PID boxes you must switch off the Ilumen PID Control box 20 minutes prior to making any changes. 2.3.2 ELECTROSTATIC DISCHARGE Never operate the Ilumen PID Solution when not properly installed or when the components are not closed properly. Always make sure the grounding of the Ilumen PID Control Box is done correctly. 3 SCOPE OF DELIVERY 3.1.1 ILUMEN PID BOX 1. 2. 3. 4. 5. 1 1 1 2 2 x x x x x Ilumen PID Box Cable with 4-pole male plug (M12) Cable with 4-pole female plug (M12) MC4 or SUNCLIX male connector MC4 or SUNCLIX female connector 3.1.2 ILUMEN PID CONTROL BOX 1. 2. 3. 4. 1 1 1 1 x x x x Ilumen PID Control Box Power cord (EU plug) Cable with 4-pole female plug (M12) Antenna 4 PRODUCT DESCRIPTION 4.1 ILUMEN PID CONTROL BOX The Ilumen PID Control Box is connected with all the Ilumen PID Boxes in series When the Ilumen PID Control Box is actively curing, the Ilumen sign is lit up. The curative periods of the solution will depend on the extend of the PID problem. When no PID is present in the installation the Ilumen PID Control Box will retain from curing. . Through GPRS communication the Ilumen PID Solutionis switched on or off automatically. Through the my.ilumen.be portal you can check if the Ilumen PID Control Box is operating correctly.You must mail the installations geographic location to [email protected] together with the Ilumen PID Control Box serial number to get your login details and activation. The Ilumen PID Control Box may never be moved to another geographic location before approval of Ilumen. Installation Manual Ilumen PID Box & Ilumen PID Control Box 5 Ilumen Installation Manual Ilumen PID Box & Ilumen PID Control Box 6 Ilumen 4.2 ILUMEN PID BOX The Ilumen PID Box is placed between the inverter and the solar array strings. The power of the strings goes through the PID Box, entering on one side and leaving on the other.One Ilumen PID Box can only be used for one MPP tracker. If you use multiple Ilumen PID Boxes you must couple them together in series with the 4-pole connectors. Always terminate the last Ilumen PID Box 4pole connector in a non-conductive and weather resistant manner. The number of working Ilumen PID Boxes can optionally be monitored through the Ilumen portal. Attention: If you work with inverters with multiple MPPT’s you cannot mix the PV arrays from multiple MPPT’s. Attention: The maximum current that can pass through the Ilumen PID Box is 34A. Make sure this is never exceeded. Attention: Make sure the PV arrays are connected to the “in” side of the Ilumen PID Box Mini, NEVER to the “out”side. 5 MOUNTING 5.1 MOUNTING LOCATION REQUIREMENTS FOR THEILUMEN PID CONTROL BOX The installation site must be freely and safely accessible at all times without the necessity for any auxiliary equipment. The mounting location should be inside a rain- and windproof location. Do not place in a dusty environment. The mounting location should be maximum 50 meters from the first Ilumen PID Box. The ambient temperature must be between -25 and 60°C. The mounting surface must be even. The wall brackets of the Ilumen PID Control Box must lie flush with the mounting surface. 5.2 MOUNTING LOCATION REQUIREMENT FOR THE ILUMEN PID BOX It can be installed outside Proper ventilation of the product is necessary. The ambient temperature must be between -25 and 60°C. The possibility to mount with screws has been foreseen but isn’t necessary Installation Manual Ilumen PID Box & Ilumen PID Control Box 7 Ilumen 5.3 MOUNTING THE ILUMEN PID SOLUTION 5.3.1 THE ILUMEN PID CONTROL BOX 1. 2. 3. 4. 5. Mark the position of the drill holes Drill the holes Insert wall plugs (if necessary) Screw the Ilumen PID Control Box to the mounting surface Check if mounted securely 5.3.2 THE ILUMEN PID BOX If you choose to mount the Ilumen PID Box you should follow this procedure: 1. 2. 3. 4. 5. Mark the position of the drill holes Drill the holes Insert wall plugs (if necessary) Screw the Ilumen PID Box to the mounting surface Check if mounted securely 6 ELECTRICAL CONNECTION When installing the Ilumen PID Solution, the AC side of the PV plant must be switched off. Also the DC switch of the inverter must be switched off. After the installation is done, you can switch the DC switch back on followed by the AC side of the PV plant. A standard EU outlet must be available on installation. This outlet should be on at all times. The ideal solution is to have a single outlet with a single circuit breaker of 16A. 6.1 AC CONNECTION To power the Ilumen PID Solution you must connect the Ilumen PID Control Box to the AC grid with the supplied power cord. Make sure the switch of the Ilumen PID Control Box is off before connecting both sides of the cord. Don’t switch on the device until commissioning. 6.2 EARTH CONNECTION To receive the best result the frames of the solar modules must be connected to the earth connector of the Ilumen PID Control Box. For optimal result you must lay a solar cable (6mm2) to the mounting structure of the solar modules (make sure mounting structures and frames of the solar modules are electrically conducting). It is important that all frames of all solar modules Installation Manual Ilumen PID Box & Ilumen PID Control Box 8 Ilumen are at the earth potential, if necessary you have to interconnect the mounting structures with additional cables. 6.3 ILUMEN PID CONTROL BOX TO ILUMEN PID BOX CONNECTION To connect the Ilumen PID Control Box to the first Ilumen PID Box the cables with 4pole connectors are used. You can use an extension cable (max 50m) in between made out of a four wire cable of 4x1.5mm² and a!!!!!!!!!!!!!! female connector on one side and male connector on the other side. The cable must be approved for outside use. Make sure the connectors are connected correctly and screwed together tightly. Cable\pin nr° 4x 1,5² 1 Brown 2 Blue 3 Green/Yellow 4 Black The pin numbering is provided on the connector. 6.4 SOLAR ARRAY AND INVERTER (MPPT) TO ILUMEN PID BOX CONNECTIONS When installing the Ilumen PID Solution between the PV array and inverter always switch off the DC switch of the inverter. TheIlumen PID Box side marked with “+” and “–“ will be connected to the inverter, the side marked with “PV+” and “PV-“ will be connected to the solar arrays. If all connectors are installed properly you can start connecting the PV arrays. Always connect the PV arrays to the Ilumen PID Solution first; On the Ilumen PID BOX the “PV+” cables should be connected to the positive side of all strings and the “PV-“ cables should be connected to the negative side of all strings. Next connect the inverter. Connect the “+” cables of the Ilumen PID Box to the positive input of the inverter (both cables MUST connect to the same MPPT input). Connect the “-“ cables of the Ilumen PID Box to the negative input of the inverter (both cables MUST connect to the same MPPT input). All unused DC inputs and outputs have to be terminated with a corresponding sealing plug. Installation Manual Ilumen PID Box & Ilumen PID Control Box 9 Ilumen Attention: If you work with inverters with multiple MPPT’s, you cannot mix the PV arrays from multiple MPPT’s. Standard rule throughout the installation is one Ilumen PID Box for each MPPT. Attention: The maximum current that can passthrough the Ilumen PID Box is 34A. Make sure this is never exceeded. Attention: Make sure the PV arrays are connected to the “PV+” and “PV-“ cables of the Ilumen PID Box, NEVER to the “+” or “-“ cables. 6.5 ILUMEN PID BOX SERIES CONNECTION Connect the 4-pole male connector of the first Ilumen PID Box to the 4-pole female connector of the Ilumen PID Control Box. Following you can connect up to 100 Ilumen PID Boxes in total in a series chain by mating each 4-pole female connector from the last chained to the 4-pole male connector of the one your adding. The end of the chain must be sealed by you in a nonconductive and weather resistant manner (e.g. by a terminator plug). Make sure the connections are screwed properly and tightly to insure the connection and the weather resistance. 7 COMMISSIONING 7.1 CHECK Do a final check whether everything is properly mounted and connected (see 5 and 6 for details): The PV frames are all connected to the same earth as the earth connection of the Ilumen PID Control Box Ilumen PID Control Box is fixed firmly against the wall Ilumen PID Control Box GPRS antenna is placed in a good wireless connectable position AC cable is correctly connected PV and inverter DC cables are correctly connected Installation Manual Ilumen PID Box & Ilumen PID Control Box 10 Ilumen Unused DC inputs and outputs on the Ilumen PID Box are terminated with a corresponding sealing plug The Ilumen PID Boxes are correctly connected to the Ilumen PID Control Box The final Ilumen PID Box is sealed in a non-conductive and weather resistant manner If all these conditions are met you can start up the Ilumen PID Solution. 7.2 STARTING UP THE ILUMEN PID SOLUTION The Ilumen PID Control Box can only apply the Ilumen PID Solution in an automatic mode. It must be connected to the my.ilumen.be portal via the GPRS at any time. To start up the Ilumen PID Box, plug in the AC power cord into a standard EU outlet (This outlet must be on at all times) and turn on the switch. Next you need to login to the my.ilumen.be portal to see if the connection is good and to finalize the installation. After approving the system it will be switched on automatically. Mail geographic location to [email protected] together with the Ilumen PID Control Box serial number to get your login details and activation. The Ilumen PID Control Box may never be moved to another geographic location before approval of Ilumen. 8 INSTALLATION SUMMARY 1) Take the necessary safety precautions (AC side of the PV plant off and DC switch of the inverter off). 2) Mount the Ilumen PID Control Box. 3) Make the AC power connection to the Ilumen PID Control Box with the power button turned off. 4) Connect the Ilumen PID Control Box and the PV frames to earth and make sure all PV frames are interconnected. 5) The Ilumen PID Box can be mounted. 6) Disconnect the PV array cables from the inverter. 7) Connect the PV array cables to the Ilumen PID Box (see 6.4 for details). 8) Connect the Ilumen PID Box to the inverter (see 6.4 for details). 9) Connect the Ilumen PID Box(es) in a series chain to the Ilumen PID Control Box. 10) Flip on the power switch of the Ilumen PID Control Box. 9 Installation Manual Ilumen PID Box & Ilumen PID Control Box 11 Ilumen 8 8 9 3 4 10 7 9 7 11) Turn the DC switch from the inverter back on followed by the AC side of the PV plant. 12) Register on my.ilumen.be. You must mail the installations geographic location to [email protected] together with the Ilumen PID Control Box serial number to get your login details and activation. The Ilumen PID Control Box may never be moved to another geographic location before approval of Ilumen. Installation Manual Ilumen PID Box & Ilumen PID Control Box 12 Ilumen 9 DECOMMISSIONING THE ILUMEN PID SOLUTION Switch off the Ilumen PID Control Box. Disconnect the Ilumen PID Control Box from the AC grid. Wait for minimum 20 minutes. Make sure the AC cannot be plugged in again. Disconnect the DC switch from the inverter and wait until it is discharged. Disconnect the Ilumen PID Box communication line first. Disconnect all DC connectors going to the PV arrays and then disconnect the lines going to the inverter. When all electrical connections are disconnected you can dismount the Ilumen PID Boxes and the Ilumen PID Control Box. The Ilumen PID Control Box may never be moved to another geographic location before approval of Ilumen. 10 TROUBLESHOOTING 10.1 NO GPRS CONNECTION In case of a bad connection with the my.ilumen.be portal you should check following things: Is the Ilumen PID Control Box properly connected to the AC grid? Is the power button of the Ilumen PID Control Box switched on? Has the location of the Ilumen PID Control Box a good GPRS connection (at least 2G GSM reception)? Try to install it on a position with better GPRS connection? Try to mount the antenna for an optimal connection? Are there any appliances in the neighborhood that can disturb the signal? 10.2 NO GOOD PID REGENERATION If the modules are not regenerating or not regenerating fast enough you should check following things: Is the Ilumen PID Control Box is properly connected to the AC grid? Is the power button of the Ilumen PID Control Box switched on? Are the Ilumen PID Boxes connected correctly? Is the communication cable connected correctly? Let an expert check that the problem you have with the yield is caused by PID? Control the grounding of the system if necessary you should place additional interconnections. Installation Manual Ilumen PID Box & Ilumen PID Control Box 13 Ilumen 11 TECHNICAL DATA Switch example monostring Switch example multistring Technical data ILUMEN PID BOX & ILUMEN PID CONTROL BOX PV array / inverter input Maximum PV voltage Output voltage to ground Maximum PV current Maximum output current in operation 1000 V Up to 1250 V 34 A 100 mA GRID (AC) Nominal AC voltage Nominal AC grid frequency Power consumption in standby operation Typical power consumption in operation Maximum power consumption 110 to 240 V 50 to 60 Hz < 0.2 W 2 W per PID BOX 600 W General data Dimensions PID BOX (∅ / H) Dimensions PID CONTROL BOX (W x D x H) Weight Operating temperature range Environmental conditions PID BOX Environmental conditions PID CONTROL BOX PID BOX PV connectors 130 / 25 mm 255 x 210 x 315 mm 200 g -25 to 60 °C (-13 to 140 °F) IP65 - indoor and outdoor use IP44 - indoor use only MC4 (optional SUNCLIX) Configuration One ILUMEN PID CONTROL BOX per project Maximum one MPPT per PID BOX None of the connected solar module poles may become grounded Number of PID BOXes per PID CONTROLLER Up to 100 (more on request) Communication On board GPRS Various Warranty Certificates Registration before use Up to 20 years www.ilumen.be www.myilumen.be Installation Manual Ilumen PID Box & Ilumen PID Control Box 14 Ilumen 12 CONTACT Ilumen bvba Ambachtsstraat 19 3980 Tessenderlo Belgium Tel: +32 13 29 75 08 [email protected] www.ilumen.be Installation Manual Ilumen PID Box & Ilumen PID Control Box 15