Psiber Data Firmenvorstellung

Transcription

Psiber Data Firmenvorstellung
Psiber Data WireXpert
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Agenda
Psiber Data WireXpert Introduction
• Company Presentation
• Why Cable Certification?
• Universal Structured Cabling
or “The Network”
• Standards
• The WireXpert
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Page 2
Psiber Data
Company Presentation
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Psiber Data Worldwide
America
EMEA
London
Boston
San Diego
Paris
APAC
Munich
Milano
Singapore
Region Office (R&D, Sales, Service)
Sales Office
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Company Mission
• Design & market world class communication test
products for enterprise networks covering all 7
network layers (ISO model).
• Sell through balanced channels, providing
technical expertise and achieving optimal market
coverage
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Seite 5
Product Segments
7. Application
6. Presentation
Application and Protocol Analysis
5. Session
4. Transport
3. Network
Handheld Network Tester
2. Data Link
1. Physical
© 2011 Psiber Data GmbH
Copper
Fibre
WLAN
Topology
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Why Cable Certification?
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Future-Safety
• Only certified cabling systems gives futuresafety that todays and future network
applications will work on today installed
cabling systems!
Class
Frequency
Network Application
Class D
100 MHz
100Base-TX, TR 100Mb/s, 100Base-T, TR 16
Mb/s, ATM155 Mb/s, FW 100Mb/s
Class E
250 MHz
ATM LAN 1,2Gb/s, 10GBase-T/50m
Class EA
500 MHz
10GBase-T/100m
Class F
600 MHz
FC1000-TP, 10GBase-T
Class FA
1000 MHz
?40 Gb/s?
Class ?
1200 / 1600 MHz
?40 Gb/s?
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Warranties / Performance
• Warranties
• Many cabling vendors require a test report from a standard based
cable certifier to apply their system warranty to a specific
installation.
• Only a full certification of an installation can ensure that
workmanship is done correct.
• „Cheap“ Cabling
• With many manufacturers claiming their cabling system to be
Class EA, only a full certification ensures that the installed
cabling meets all standard requirements.
• Storage of certification data proves future
possibilities of cabling
• While current standards only define cabling up to Class EA for
10G, captured data may prove that cabling is certified for future
technologies such as 40G.
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Page 9
Universal Structured
Cabling
or “The Network”
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Principle of Structured Cabling
• Universal Structured Cabling
• This principle is described in
all standards:
• Campus Cabling
• Connects the buildings with the
Campus Distributor (CD) - most
only fiber connections
• Backbone Cabling
• Connects the floors with the
building distributor (BD) – fiber and
copper connections
• Horizontal Cabling
• Connects the workplaces with the
Floor Distributor (FD) – most
copper and sometimes fiber
connections
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Page 11
Cabling Standards
„ISO 11801 / TIA 568 / EN 50173“
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
What Standards do we have?
ISO/IEC 11801
Europe
USA
IEEE 802.3
EN50173
TIA/EIA 568 C
Standards for passive cabling
Standards for active
transmission systems
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Page 13
Cabling Standards
100 MHz
250 MHz
500 MHz
USA
TIA/EIA
568-C
Cat. 5e
TIA/EIA
568-C
Cat.6
TIA/EIA
568-C
Cat.6A
International
ISO/IEC11801
Edition 2.1
Class D
2009
ISO/IEC11801
Edition 2.1
Class E
2009
Europe
CENELEC
EN50173-1
Class D
2010
CENELEC
EN50173-1
Class E
2010
600 MHz
1000 MHz
ISO/IEC11801
Edition 2.1
Class EA
2009
ISO/IEC11801
Edition 2.1
Class F
2009
ISO/IEC11801
Edition 2.1
Class FA
2009
CENELEC
EN50173-1
Class EA
2010
CENELEC
EN 50173-1
Class F
2010
CENELEC
EN 50173-1
Class FA
2010
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Page 14
What is standardised?
Components
Transmission Links
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Page 15
… and the Cable Certifier!
DSP-100
DSP -2000
DSP- 4000
DSP- 4100
DSP- 4300
DTX – 1800
DTX-1200
OmniScanner
OmniScanner 2
OmniScanner LT
PentaScanner
PentaScanner +
Lantek Pro LT8100
Lantek Pro XL LT8155
LT8600
WireScope 155
Lantek 7
Lantek 6
Lantek 6A
Lantek II – 350 Lantek II – 500
Lantek 7G
Lantek II – 1000
WireScope Pro
WireScope 350
1200 MHz
Cat. 5/5e
Class D
Cat. 6
Class E
© 2011 Psiber Data GmbH
Cat. 6A
Class EA
10G Ethernet
Class FA
40G Ethernet
PAM 32/DSQ 512
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
40G Ethernet
PAM 16/DSQ 128
Psiber Data WireXpert
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
New Measurement Engine
• Due to new developments in
semiconductors new chips
that became available in the
last 2-3 years
• State of the art and patent
pending design
• High accurate 4 port vector
analyser platform
• Driven by high density FPGA
to deliver real time high
accuracy
• Leap frogging legacy testers
by overcoming frequency
limitation of older designs
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Page 18
Comparison Graphs
WireXpert vs Networkanalyzer
70
60
50
40
RL_36
30
RL_green
20
10
0
0
200000
400000
600000
800000
1000000 1200000 1400000 1600000 1800000 2000000
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Page 19
WireXpert’s Interfaces
Power on-off button
Touch sensitive color LCD screen
USB device connector
Audio jack
USB host connector for flash drive
RJ-45 Ethernet for remote control
Power supply jack (12V)
Quick access buttons
Up-down-left-right scroll buttons
Context sensitive Help
Brightness control
Probe interface connector
Battery compartment door
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Page 20
Value Proposition
Future Proof
• Highest frequency range in the industry
• The only tester supporting all new test requirements and beyond
• Field upgradeable & re-evaluation for future standards
Reliability & Robustness
• Accuracy beyond Level IV
• Sustains drop test from 1.5m on a concrete floor
• No mechanical controls, only power button
Cost of Ownership
• No upgrade cost from Cat6 to Cat6A to Class FA
• Low cost of consumable accessories (permanent link test cord, battery etc.)
Extreme productivity
• Shortest test time in the industry (less then 9 seconds)
• 2 Main unit design reduces walk time to half and improve work flow
Ease of Use
• Built-in user manual
• Easy touch sensitive user interface on both local and remote units
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Page 21
Productivity and Ease of Use
New Dual Control System (DCSTM) –
featuring identical devices for remote and main units
- makes it really easy to operate the test cycles.
Whether coordinated by two technicians or only one,
walking time is minimized.
•
•
•
•
•
•
•
control of both sides
reduce walking by 50%
certification could be carried out by just one technician
2 sets could be transform into one main with 3 remotes
total visibility on both sides
If battery needs charging units simply can be swapped
in the unlikely event of failure, service center will have
spare unit available
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Page 22
Dual Control System (DCS™)
PASS
SAVE
PASS
SAVE
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Productivity and Ease of Use
Data transfer and update via USB drive
unit stays in the field all time
Easy to use
Intuitive user interface makes change
over easy
Responsive and fast usability by
Fingers touch
Maximum 2 clicks away from resolution
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Page 24
High Reliable Concept of Test Heads
• Concept of test heads for
Permanent Link adds to high
reliability and reproducibility
• RJ-45 needs to be replaced after
x000 insertions/tests
• Cable Material wears out after
coiling and bending
• WireXpert Permanent Link
solution minimizes cost of
ownership
• Conclusion: both RJ-45 & cable
need regular exchange… Fluke
solution expensive only repairs
contacts
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Page 25
How do we test? Preparations
A few preparations:
1. Select Cabling Standard
• Select standard
• Select class or category
2. Select Cable
• Select manufacturer
• Select cable
3. Select connecting hardware
• Select manufacturer
• Select connector
4. Setup the Site
• Select from database or name site
5. Setup Labeling
• Select the labeling scheme
6. Setup Operator
• Select operator or key in a name
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Page 26
How do we test? Autotests
• Start an Autotest by pressing:
• <9s later you will get a result:
• Detailed results by pressing:
• Select single item to
view graphs
OR
• Save result by twice pressing:
Thats all!
Start the next Autotest!
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Page 27
All Autotests done! Whats now?
After you have tested all links on
site, copy these to an USB - Stick
1. Insert USB - Stick into the USB
Host connector of the Local unit
2. The Local unit recognizes the
USB - Stick
3. And shows the menu
4. Press
5. The unit copies all test results
from your site to the USB - Stick
6. Remove the USB - Stick
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Page 28
ReportXpert
With the Autotests on the USB - Stick, we now can
read them into the ReportXpert Software and
• Manage the Autotests,
• View the Autotests,
• Pack the projects,
• Print Detailed Reports of the Autotests or
• Print Summary Reports of the project
© 2011 Psiber Data GmbH
14.11.2011
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Page 29
WireXpert – What is in the Box
Bill of Material WireXpert WX4500
2 pcs.
Identical main units including:
Li-Ion battery, strap set, stylus w. cord & display cover
1 pc.
Carrying Case
2 pcs.
CAT6A Permanent Link Interface Adapter
2 pcs.
CAT6A Permanent Link Test Cords
2 pcs.
CAT6A Channel Adapter
1 pc.
1GB USB Thumb Drive
2 pcs.
Talk Sets
2 pcs.
AC Power Adapters
2 pcs.
Country Specific Power Cord
1 pc.
Calibration Certificate
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Page 30
WireXpert at a Glance
Fastest Handheld Copper and Fiber Testing
for up to 40 Gbit/s Ethernet Networks
• Cat 6a/ Class E, Cat 7a/ Class FA copper certification
• Multi- / single mode fiber certification for length & loss
• Future-proof through 1…1600 MHz frequency range
and software upgradeability
• Supports all current standards such as ISO 11801,
EN50173, TIA 568
• Exceeds TIA Level IV accuracy specifications, sets
new standard for proposed “Level V”
• Dual Control System (DCS) with two main units
improves operator efficiency
• Alien Crosstalk measurement for 10G over copper
• User friendly with vendor managed cable database,
pre-defined settings and a workday of battery life
• Supports autotest and continuous measurement
• Semi automated software upgrade
© 2011 Psiber Data GmbH
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS
Page 31
End!
Many thanks for your attention!
Any questions?
PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS