Psiber Data Firmenvorstellung
Transcription
Psiber Data Firmenvorstellung
Psiber Data WireXpert PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Agenda Psiber Data WireXpert Introduction • Company Presentation • Why Cable Certification? • Universal Structured Cabling or “The Network” • Standards • The WireXpert © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Page 2 Psiber Data Company Presentation PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Psiber Data Worldwide America EMEA London Boston San Diego Paris APAC Munich Milano Singapore Region Office (R&D, Sales, Service) Sales Office © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Company Mission • Design & market world class communication test products for enterprise networks covering all 7 network layers (ISO model). • Sell through balanced channels, providing technical expertise and achieving optimal market coverage © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Seite 5 Product Segments 7. Application 6. Presentation Application and Protocol Analysis 5. Session 4. Transport 3. Network Handheld Network Tester 2. Data Link 1. Physical © 2011 Psiber Data GmbH Copper Fibre WLAN Topology PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Why Cable Certification? PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Future-Safety • Only certified cabling systems gives futuresafety that todays and future network applications will work on today installed cabling systems! Class Frequency Network Application Class D 100 MHz 100Base-TX, TR 100Mb/s, 100Base-T, TR 16 Mb/s, ATM155 Mb/s, FW 100Mb/s Class E 250 MHz ATM LAN 1,2Gb/s, 10GBase-T/50m Class EA 500 MHz 10GBase-T/100m Class F 600 MHz FC1000-TP, 10GBase-T Class FA 1000 MHz ?40 Gb/s? Class ? 1200 / 1600 MHz ?40 Gb/s? © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Warranties / Performance • Warranties • Many cabling vendors require a test report from a standard based cable certifier to apply their system warranty to a specific installation. • Only a full certification of an installation can ensure that workmanship is done correct. • „Cheap“ Cabling • With many manufacturers claiming their cabling system to be Class EA, only a full certification ensures that the installed cabling meets all standard requirements. • Storage of certification data proves future possibilities of cabling • While current standards only define cabling up to Class EA for 10G, captured data may prove that cabling is certified for future technologies such as 40G. © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Page 9 Universal Structured Cabling or “The Network” PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Principle of Structured Cabling • Universal Structured Cabling • This principle is described in all standards: • Campus Cabling • Connects the buildings with the Campus Distributor (CD) - most only fiber connections • Backbone Cabling • Connects the floors with the building distributor (BD) – fiber and copper connections • Horizontal Cabling • Connects the workplaces with the Floor Distributor (FD) – most copper and sometimes fiber connections © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Page 11 Cabling Standards „ISO 11801 / TIA 568 / EN 50173“ PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS What Standards do we have? ISO/IEC 11801 Europe USA IEEE 802.3 EN50173 TIA/EIA 568 C Standards for passive cabling Standards for active transmission systems © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Page 13 Cabling Standards 100 MHz 250 MHz 500 MHz USA TIA/EIA 568-C Cat. 5e TIA/EIA 568-C Cat.6 TIA/EIA 568-C Cat.6A International ISO/IEC11801 Edition 2.1 Class D 2009 ISO/IEC11801 Edition 2.1 Class E 2009 Europe CENELEC EN50173-1 Class D 2010 CENELEC EN50173-1 Class E 2010 600 MHz 1000 MHz ISO/IEC11801 Edition 2.1 Class EA 2009 ISO/IEC11801 Edition 2.1 Class F 2009 ISO/IEC11801 Edition 2.1 Class FA 2009 CENELEC EN50173-1 Class EA 2010 CENELEC EN 50173-1 Class F 2010 CENELEC EN 50173-1 Class FA 2010 © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Page 14 What is standardised? Components Transmission Links © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Page 15 … and the Cable Certifier! DSP-100 DSP -2000 DSP- 4000 DSP- 4100 DSP- 4300 DTX – 1800 DTX-1200 OmniScanner OmniScanner 2 OmniScanner LT PentaScanner PentaScanner + Lantek Pro LT8100 Lantek Pro XL LT8155 LT8600 WireScope 155 Lantek 7 Lantek 6 Lantek 6A Lantek II – 350 Lantek II – 500 Lantek 7G Lantek II – 1000 WireScope Pro WireScope 350 1200 MHz Cat. 5/5e Class D Cat. 6 Class E © 2011 Psiber Data GmbH Cat. 6A Class EA 10G Ethernet Class FA 40G Ethernet PAM 32/DSQ 512 PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS 40G Ethernet PAM 16/DSQ 128 Psiber Data WireXpert PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS New Measurement Engine • Due to new developments in semiconductors new chips that became available in the last 2-3 years • State of the art and patent pending design • High accurate 4 port vector analyser platform • Driven by high density FPGA to deliver real time high accuracy • Leap frogging legacy testers by overcoming frequency limitation of older designs © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Page 18 Comparison Graphs WireXpert vs Networkanalyzer 70 60 50 40 RL_36 30 RL_green 20 10 0 0 200000 400000 600000 800000 1000000 1200000 1400000 1600000 1800000 2000000 © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Page 19 WireXpert’s Interfaces Power on-off button Touch sensitive color LCD screen USB device connector Audio jack USB host connector for flash drive RJ-45 Ethernet for remote control Power supply jack (12V) Quick access buttons Up-down-left-right scroll buttons Context sensitive Help Brightness control Probe interface connector Battery compartment door © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Page 20 Value Proposition Future Proof • Highest frequency range in the industry • The only tester supporting all new test requirements and beyond • Field upgradeable & re-evaluation for future standards Reliability & Robustness • Accuracy beyond Level IV • Sustains drop test from 1.5m on a concrete floor • No mechanical controls, only power button Cost of Ownership • No upgrade cost from Cat6 to Cat6A to Class FA • Low cost of consumable accessories (permanent link test cord, battery etc.) Extreme productivity • Shortest test time in the industry (less then 9 seconds) • 2 Main unit design reduces walk time to half and improve work flow Ease of Use • Built-in user manual • Easy touch sensitive user interface on both local and remote units © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Page 21 Productivity and Ease of Use New Dual Control System (DCSTM) – featuring identical devices for remote and main units - makes it really easy to operate the test cycles. Whether coordinated by two technicians or only one, walking time is minimized. • • • • • • • control of both sides reduce walking by 50% certification could be carried out by just one technician 2 sets could be transform into one main with 3 remotes total visibility on both sides If battery needs charging units simply can be swapped in the unlikely event of failure, service center will have spare unit available © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Page 22 Dual Control System (DCS™) PASS SAVE PASS SAVE © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Productivity and Ease of Use Data transfer and update via USB drive unit stays in the field all time Easy to use Intuitive user interface makes change over easy Responsive and fast usability by Fingers touch Maximum 2 clicks away from resolution © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Page 24 High Reliable Concept of Test Heads • Concept of test heads for Permanent Link adds to high reliability and reproducibility • RJ-45 needs to be replaced after x000 insertions/tests • Cable Material wears out after coiling and bending • WireXpert Permanent Link solution minimizes cost of ownership • Conclusion: both RJ-45 & cable need regular exchange… Fluke solution expensive only repairs contacts © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Page 25 How do we test? Preparations A few preparations: 1. Select Cabling Standard • Select standard • Select class or category 2. Select Cable • Select manufacturer • Select cable 3. Select connecting hardware • Select manufacturer • Select connector 4. Setup the Site • Select from database or name site 5. Setup Labeling • Select the labeling scheme 6. Setup Operator • Select operator or key in a name © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Page 26 How do we test? Autotests • Start an Autotest by pressing: • <9s later you will get a result: • Detailed results by pressing: • Select single item to view graphs OR • Save result by twice pressing: Thats all! Start the next Autotest! © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Page 27 All Autotests done! Whats now? After you have tested all links on site, copy these to an USB - Stick 1. Insert USB - Stick into the USB Host connector of the Local unit 2. The Local unit recognizes the USB - Stick 3. And shows the menu 4. Press 5. The unit copies all test results from your site to the USB - Stick 6. Remove the USB - Stick © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Page 28 ReportXpert With the Autotests on the USB - Stick, we now can read them into the ReportXpert Software and • Manage the Autotests, • View the Autotests, • Pack the projects, • Print Detailed Reports of the Autotests or • Print Summary Reports of the project © 2011 Psiber Data GmbH 14.11.2011 PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Page 29 WireXpert – What is in the Box Bill of Material WireXpert WX4500 2 pcs. Identical main units including: Li-Ion battery, strap set, stylus w. cord & display cover 1 pc. Carrying Case 2 pcs. CAT6A Permanent Link Interface Adapter 2 pcs. CAT6A Permanent Link Test Cords 2 pcs. CAT6A Channel Adapter 1 pc. 1GB USB Thumb Drive 2 pcs. Talk Sets 2 pcs. AC Power Adapters 2 pcs. Country Specific Power Cord 1 pc. Calibration Certificate © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Page 30 WireXpert at a Glance Fastest Handheld Copper and Fiber Testing for up to 40 Gbit/s Ethernet Networks • Cat 6a/ Class E, Cat 7a/ Class FA copper certification • Multi- / single mode fiber certification for length & loss • Future-proof through 1…1600 MHz frequency range and software upgradeability • Supports all current standards such as ISO 11801, EN50173, TIA 568 • Exceeds TIA Level IV accuracy specifications, sets new standard for proposed “Level V” • Dual Control System (DCS) with two main units improves operator efficiency • Alien Crosstalk measurement for 10G over copper • User friendly with vendor managed cable database, pre-defined settings and a workday of battery life • Supports autotest and continuous measurement • Semi automated software upgrade © 2011 Psiber Data GmbH PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS Page 31 End! Many thanks for your attention! Any questions? PROFESSIONAL NETWORK TESTING & PROTOCOL ANALYSIS