WICONA series
Transcription
WICONA series
T E C H N O L O G Y WICONA series F O R I D E A S INTRODUCTION 2 ADIDAS, Herzogenaurach kadawittfeldarchitektur Rupert App GmbH & Co. T E C H N O L O G Y F O R I D E A S Content WICONA series Stick system façades 4 Unitized façades 7 Integration sashes 8 Windows9 Doors12 Photo: Werner Huthmacher Sliding systems 14 3 STICK SYSTEM FAÇADES Name / series Main advantages ■■ Passive house curtain wall Structural glazing curtain wall SG Design with integrated pressure profile 4 Basic series for individual adaptations according to the WICONA Unisys technology ■■ Sight line 50 mm ■■ Profile depth 50 – 260 mm ■■ Infill thickness 3 – 63 mm ■■ Certified passive house component (ift) Applications / opening types Performance features ■■ Curtain wall ■■ Uf until 1.2 W / (m2K) ■■ Glass roof constructions ■■ Sound insulation until 47 dB ■■ 3D spatial constructions (Polygonal façades up to 45°) ■■ ■■ Curtain wall ■■ Polygonal façades up to 5° Special functions ■■ Burglar resistance in class WK1, WK2, WK3 System tests according to DIN EN 13830 for CE marking ■■ Bullet resistance in class FB4 ■■ Integrated sunshade (special guide rails in external cover profiles) ■■ Uf until 0.74 W / (m2K) ■■ ■■ Uw Passive house < 0.8 W / (m K) Burglar resistance in class WK1, WK2 ■■ System tests according to DIN EN 13830 for CE marking ■■ Opening units in all-glass design: see integration sashes ■■ Burglar resistance in class WK1 2 ■■ Profile depth 50 – 260 mm ■■ Infill thickness 24 – 51 mm ■■ WICTEC 50 with complementary special insulation profile ■■ SG structural glazing technology ■■ Curtain wall ■■ Uf until 1.5 W / (m2K) ■■ On the basis of WICTEC 50 ■■ Glass roof constructions ■■ ■■ With European Approval ETA ■■ Semi façades (combined with pressure profiles) System tests according to DIN EN 13830 for CE marking ■■ Integrated pressure profiles, overlying or flush to glass ■■ ■■ System tests according to DIN EN 13830 for CE marking ■■ No SG-approval required Curtain wall with optical characteristics of a Structural glazing SG façade ■■ Profile width 43 or 51 mm Section drawing STICK SYSTEM FAÇADES Name / series Main advantages ■■ Add-on construction for steel or wood Mullion / mullion curtain wall Fire protection System for direct glazing on structures made from customary steel of wood profiles ■■ Sight line 50 mm ■■ Sealing and tightness assured by a continuous gasket ■■ Stick system with identical profiles for mullion and transom Applications / opening types Performance features ■■ Curtain wall ■■ Uf until 1.2 W / (m2K) ■■ Glass roof constructions ■■ System tests according to DIN EN 13830 for CE marking ■■ Curtain wall ■■ Uf until 1.2 W / (m2K) ■■ System tests according to DIN EN 13830 for CE marking ■■ Straight profile cut, no notching required ■■ Sealing and tightness assured by a continuous gasket ■■ Fire protection curtain wall ■■ Curtain wall ■■ Uf until 1.4 W / (m2K) ■■ For glazing or panels up to 1.8 x 3.0 m or 2.4 x 1.4 m ■■ Overhead glazing until 0° slope ■■ ■■ Polygonal constructions up to 5° System tests according to DIN EN 13830 for CE marking ■■ With several national general approvals Special functions ■■ Burglar resistance in class WK1, WK2 ■■ Burglar resistance in class WK1, WK2 ■■ Fire resistance in class G30 / F30 Section drawing 5 STICK SYSTEM FAÇADES Name / series Main advantages ■■ Fire protection Fire protection parapet 6 Basic series for individual adaptations according to the WICONA Unisys technology Applications / opening types Performance features ■■ Curtain wall ■■ Uf until 1.2 W / (m2K) ■■ Glass roof constructions ■■ Sound insulation until 47 dB ■■ 3D spatial constructions ■■ Special functions ■■ Burglar resistance in class WK1, WK2, WK3 System tests according to DIN EN 13830 for CE marking ■■ Bullet resistance in class FB4 ■■ Fire resistance in class G30 / F30 ■■ Sight line 60 mm ■■ Profile depth 70 – 170 mm ■■ Infill thickness 3 – 51 mm ■■ Fire protection curtain wall ■■ Curtain wall ■■ Uf until 1.4 W / (m2K) ■■ For glazing or panels up to 1.8 x 3.0 m or 2.4 x 1.4 m ■■ Overhead glazing until 0° slope ■■ System tests according to DIN EN 13830 for CE marking ■■ With several national general approvals ■■ Fire protection class W90 ■■ ■■ Exterior layer in glass or aluminium Integration in stick curtain walls to prevent flash over of fire from storey to storey Section drawing U N I T I Z E D F açades Name / series Main advantages ■■ Unitized curtain wall on stick system base ■■ Exterior glazing beads with mitre cut, leading to a picture frame design ■■ Sight lines 50 / 65 mm ■■ Exterior glazing beads with mitre cut, leading to a picture frame design ■■ Applications / opening types ■■ Unitized curtain wall for complete pre-assembly in the workshop, including glazing and parapet elements ■■ Unit size until 3.5 m height and 3.0 m width (storey height) ■■ Unitized curtain wall for complete pre-assembly in the workshop, including glazing and parapet elements Sight line 60 mm ■■ Performance features ■■ Uf until 1.4 W / (m2K) ■■ System tests according to DIN EN 13830 for CE marking ■■ Uf until 1.6 W / (m2K) ■■ System tests according to DIN EN 13830 for CE marking Special functions Section drawing Unit size until 3.5 m height and 2.8 m width (storey height) 7 I N T E G R AT I O N S A S H E S Name / series Roof light vent sash Lowering and projecting top-hung window SG Main advantages ■■ Sight line 81 mm ■■ Concealed hinges with opening angle 90° ■■ ■■ ■■ Applications / opening types ■■ Application in WICTEC 50 / 60 glass roof constructions until 10° slope Glass level offset only 36 mm ■■ Sash size until 1.4 x 1.8 m or 1.8 x 1.4 m Outward opening sashes in Structural Glazing SG Design ■■ Lowering and projecting top-hung window size until 1.5 x 2.5 m or 2.0 x 1.5 m For manual or motorized operation ■■ Parallel outward opening sash size until 1.5 x 3.0 m or 2.0 x 1.5 m ■■ Inward opening: Turn-tilt, turn, tilt, tilt-first, double casement Parallel outward opening window SG ■■ Complete system advantages of the comprehensive WICLINE evo window series ■■ See windows Performance features ■■ System tests according to DIN EN 14351-1 for CE marking ■■ Uf until 1.6 W / (m2K) ■■ System tests according to DIN EN 14351-1 for CE marking ■■ Uf until 1.4 W / (m2K) ■■ Uw until 1.2 W / (m2K) ■■ System tests according to DIN EN 14351-1 for CE marking Outward opening: Top-hung, Italian, pivot (horizontal / vertical) Special functions ■■ NSHE (Natural smoke and heat exhaust ventilators) ■■ Glazing with pressure profile or spot holder ■■ Application in WICTEC 50SG Structural glazing curtain wall or in WICTEC 50 curtain wall with pressure profiles ■■ Burglar resistance in class WK1, WK2, WK3 ■■ Concealed sash ■■ Classic design Section drawing Example shown: concealed sash ■■ Ventilation flap 8 Slim opening sash for manual ventilation ■■ Width 250 mm ■■ Height until 2.25 m ■■ Turn sash made of only one thermally broken aluminium profile ■■ Uf until 1.6 W / (m2K) ■■ Sound insulation until 41 dB ■■ Sound insulation in open position until 21 dB resp. 26 dB depending on the ventilation type WINDOWS Name / series Main advantages ■■ ■■ Profile depth 65 mm ■■ Infill thickness 3 – 60 mm ■■ Fittings concealed or visible, until 160 kg sash weight ■■ Minergie-P Module window Basic series for individual adaptations according to the WICONA Unisys technology ■■ Profile depth 65 mm ■■ Infill thickness 6 – 70 mm ■■ Fittings concealed or visible, until 160 kg sash weight ■■ Certified according to the Swiss Minergie-P Standard ■■ Profile depth 85 mm ■■ Slim frame construction, no visible sash frame ■■ Concealed sash Basic series for individual adaptations according to the WICONA Unisys technology Profile depth 75 / 85 mm Applications / opening types ■■ ■■ ■■ Inward opening: Turn-tilt, turn, tilt, tilt-first, double casement, fanlight, parallel sliding / tilt, French window (window-door) Performance features ■■ Uf until 1.4 W / (m2K) ■■ Uw until 1.2 W / (m2K) ■■ System tests according to DIN EN 14351-1 for CE marking Outward opening: Top-hung, Italian, French, pivot (horizontal / vertical) Inward opening: Turn-tilt, turn, tilt, tilt-first, double casement, fanlight, parallel sliding / tilt, French window (window-door) ■■ Outward opening: Top-hung, Italian, French, pivot (horizontal / vertical) ■■ Double Casement turn window ■■ Turn-tilt, with overlapping sash ■■ Inward opening: Turn-tilt, turn, tilt-first, double casement, fanlight ■■ Uf until 1.2 W / (m2K) ■■ Uw until 0.9 W / (m K) ■■ System tests according to DIN EN 14351-1 for CE marking Special functions ■■ Burglar resistance in class WK1, WK2, WK3 and RC1, RC2, RC3 ■■ Bullet resistance* ■■ Integration in stick system curtain walls ■■ Minergie window (according to Swiss Minergie standard) ■■ Burglar resistance in class WK1, WK2, WK3 and RC1, RC2, RC3 ■■ Bullet resistance* ■■ Integration in stick system curtain walls ■■ Burglar resistance in class WK1, WK2, WK3 and RC1, RC2, RC3 ■■ Integration in stick system curtain walls 2 ■■ Uw according to Minergie-P specification < 0,8 W / (m2K) ■■ Uf until 1.8 W / (m2K) ■■ Uw until 1.0 W / (m K) ■■ System tests according to DIN EN 14351-1 for CE marking 2 * In preparation Section drawing 9 WINDOWS Name / series Main advantages ■■ Classic design French window (window-door), barrier free Industry design 10 Performance features ■■ Turn ■■ Uf until 1.2 W / (m2K) ■■ Turn-tilt ■■ Uw until 0.9 W / (m2K) ■■ System tests according to DIN EN 14351-1 for CE marking ■■ Profile depth 75 / 85 mm ■■ Double casement ■■ Fittings concealed or visible, until 160 kg sash weight ■■ Tilt-first ■■ Fanlight ■■ Opening inward or outward ■■ Turn ■■ Uf until 1.3 W / (m2K) ■■ With barrier free threshold ■■ Turn-tilt ■■ Uw until 0.9 W / (m2K) ■■ Sash size until 1.70 x 2.50 m ■■ Double casement ■■ ■■ Lockable ■■ Tilt-first System tests according to DIN EN 14351-1 for CE marking ■■ Profile contours of classical steel window profiles ■■ Turn ■■ ■■ Turn-tilt System tests according to DIN EN 14351-1 for CE marking ■■ Ideal for renovations ■■ Double casement ■■ Profile depth 77 mm ■■ Tilt-first ■■ Fanlight ■■ Turn ■■ Turn-tilt ■■ Double casement ■■ Tilt-first ■■ Fanlight ■■ French window (window -door) ■■ Non-insulated 30° bevelled profiles with overlapping sash Applications / opening types ■■ Non-insulated profiles for interior application Profile depth 65 mm Special functions ■■ Burglar resistance in class WK1, WK2, WK3 and RC1, RC2, RC3 ■■ Integration in stick system curtain walls ■■ Burglar resistance in class WK1, WK2, WK3 Section drawing WINDOWS Name / series Main advantages ■■ Coupled window ■■ ■■ Hybrid window Coupled window with additional connected sash Applications / opening types Performance features ■■ Turn ■■ Uw until 0.9 W / (m2K) ■■ Turn-tilt ■■ Sound insulation until 48 (-2 / -5) dB ■■ System tests according to DIN EN 14351-1 for CE marking Improved thermal and sound insulation Profile depth 125 mm ■■ Window with Hybrid technology ■■ Double skin design with 2 sash types ■■ Improved thermal and acoustic insulation ■■ Profile depth 215 mm ■■ Optimized user comfort ■■ ■■ Interior sash: turn, turn-tilt Exterior sash: Parallel outward opening with motor operation ■■ Uw until 0.65 W / (m2K) ■■ Sound insulation until 57 dB Special functions ■■ Burglar resistance in class WK1, WK2, WK3 ■■ Exterior sash can be with single or double glazing, concealed, with industry design or in SG structural glazing technology ■■ Sun protection device can be integrated between the sashes ■■ Sun protection device can be integrated between the sashes ■■ Automatic operation for night cooling Section drawing 11 DOORS Name / series Main advantages ■■ ■■ Profile depth 65 mm ■■ Infill thickness 2 – 50 mm ■■ Sash weight until 200 kg ■■ Possible in Classic design with 30° bevelled profile contour ■■ Single and double leaf hinged door ■■ Uf until 1.8 W / (m2K) ■■ Inward and outward opening ■■ Sound insulation until 43 dB ■■ Push-pull door* ■■ ■■ Finger protection door* System tests according to DIN EN 14351-1 for CE marking ■■ All-glass door* ■■ Single action doors* ■■ Fixed and movable lateral parts ■■ Fanlight ■■ Single and double leaf hinged door ■■ Uf until 1.6 W / (m2K) ■■ Uw until below 0.8 W / (m K) Special functions ■■ Burglar resistance in class WK1, WK2, WK3 ■■ Integration in stick system curtain walls ■■ Panic function according to DIN EN 179 / 1125 ■■ Leaf overlapping infill (single or double side) on demand ■■ Burglar resistance in class WK1, WK2, WK3 ■■ Integration in stick system curtain walls 2 ■■ Inward and outward opening ■■ Sound insulation until 43 dB ■■ System tests according to DIN EN 14351-1 for CE marking ■■ Leaf overlapping infill (single or double side) on demand ■■ Uf until 2.1 W / (m2K) ■■ ■■ Sound insulation until 42 dB Burglar resistance in class WK1, WK2, WK3 ■■ System tests according to DIN EN 14351-1 for CE marking Profile depth 75 mm ■■ Push-pull door ■■ Infill thickness 3 – 60 mm ■■ Finger protection door ■■ Sash weight until 200 kg ■■ Push-pull doors ■■ Possible in Classic design with 30° bevelled profile contour ■■ Fixed and movable lateral parts ■■ Fanlight Entrance door system with individual execution options ■■ Single and double leaf hinged door Profile depth 88 mm ■■ Inward and outward opening ■■ Fixed and movable lateral parts ■■ Fanlight ■■ 12 Basic series for individual adaptations according to the WICONA Unisys technology Performance features ■■ ■■ ■■ Non-insulated Basic series for individual adaptations according to the WICONA Unisys technology Applications / opening types ■■ Non-insulated profiles for interior application ■■ Single and double leaf hinged door ■■ Profile depth 50 mm ■■ Inward and outward opening ■■ Fixed and movable lateral parts ■■ Fanlight * In preparation Section drawing DOORS Name / series Main advantages ■■ Non-insulated Fire protection door ■■ Profile depth 65 mm ■■ Single and double leaf hinged door ■■ Inward and outward opening ■■ Fixed and movable lateral parts ■■ Bullet resistance in class FB4 ■■ Fanlight ■■ ■■ Single action door Panic function according to DIN EN 179 / 1125 ■■ Finger protection door ■■ ■■ All-glass door Smoke protection in Class RS1, RS2 ■■ Fire protection in class EI30 / T30 / F30 ■■ With additional insertion strips in class EI60 / T60 ■■ Panic function according to DIN EN 179 / 1125 ■■ Smoke protection ■■ Special functions depending on national regulations ■■ Multiple fittings and lock options Fire protection door ■■ Single and double leaf hinged door Profile depth 77 mm ■■ Inward and outward opening ■■ Fixed and movable lateral parts ■■ Fanlight ■■ For interior application ■■ Profile depth 100 mm ■■ Tested as complete system (with drive unit) according to DIN EN 14351-1 Automatic sliding door ■■ Sash size until 2.0 x 3.0 m ■■ Single and double leaf hinged door ■■ Inward and outward opening ■■ ■■ ■■ Fanlight ■■ ■■ System tests according to DIN EN 14351-1 for CE marking Special functions Burglar resistance in class WK1, WK2 ■■ Fire protection system ready-to-install Performance features ■■ ■■ ■■ Fire protection door Non-insulated profiles for interior application Applications / opening types System tests according to DIN EN 14351-1 for CE marking ■■ Fire protection in class T90 / F90 Single and double leaf sliding door ■■ Ud until below 1.5 W/m2K Fixed and movable lateral parts ■■ System tests according to DIN EN 14351-1 for CE marking Section drawing 13 SLIDING SYSTEMS Name / series Main advantages Performance features ■■ Circumferential outer frame ■■ Lifting sliding door ■■ Uw < 1.0 W / (m2K) ■■ Construction depth 160 mm (double track) ■■ Double track ■■ ■■ Sliding or fixed sash System tests according to DIN EN 14351-1 for CE marking ■■ Sash size until 3.24 x 3.4 m ■■ Construction depth 160 mm (double track) or 240 mm (triple track) ■■ Lifting sliding door / window, sliding door / window ■■ Uw < 1.3 W / (m2K) ■■ System tests according to DIN EN 14351-1 for CE marking ■■ Double or triple track ■■ Sash depth 60 mm ■■ Fixed sash ■■ Sash size until 2.41 x 2.5 m ■■ 2 to 6 leaves ■■ Construction depth 105 mm (double track) or 160 mm (triple track) ■■ Lifting sliding door / window, sliding door / window ■■ Double or triple track ■■ Sash depth 40 mm ■■ Fixed sash ■■ Sash size until 2.1 x 2.45 m ■■ 2 to 6 leaves ■■ Construction depth 50 mm (double track) or 92 mm (triple track) ■■ Sliding door / window ■■ Double or triple track ■■ Fixed sash ■■ 2 to 6 leaves ■■ 14 Applications / opening types Sash depth 34 mm ■■ Uw < 1.6 W / (m2K) ■■ System tests according to DIN EN 14351-1 for CE marking Special functions ■■ Integration in stick system constructions ■■ Burglar resistance in class WK1, WK2 ■■ Integration in stick system constructions ■■ Burglar resistance in class WK1, WK2 ■■ Integration in stick system constructions Section drawing SLIDING SYSTEMS Name / series Main advantages ■■ ■■ Non-insulated profiles for interior application Construction depth 50 mm (double track) or 92 mm (triple track) ■■ Sash 34 mm ■■ Folding sliding system with partition to the right or to the left ■■ Applications / opening types Performance features ■■ Sliding door / window ■■ Double or triple track ■■ Fixed sash ■■ 2 to 6 leaves ■■ Folding sliding door ■■ Uw until 1.3 W / (m2K) ■■ With single or double casement sash ■■ System tests according to DIN EN 14351-1 for CE marking ■■ Turn or turn-tilt opening ■■ 2 to 7 leaves Inward and outward opening Special functions ■■ Section drawing Low threshold for barrier free access 15 T E C H N O L O G Y F O R WICONA series Germany: Hydro Building Systems GmbH Söflinger Straße 70 D-89077 Ulm Phone +49 731 3984-0 Telefax +49 731 3984-241 www.wicona.de Austria: Hydro Building Systems GmbH Wallerseestrasse 49 A-5201 Seekirchen Phone +43 (0) 6212 2000 Fax +43 (0) 6212 20236 www.wicona.at Slovenia: Hydro Building Systems GmbH Kozjak nad Pesnico 34b SLO-2201 Zg. Kungota Phone +386 (0) 26 209970 Fax +386 (0) 26 209218 www.wicona.at Estonia / Latvia / Lithuania: Hydro Building Systems OÜ Pärnu mnt. 139 f EST-11317, Tallinn Phone +37 2657 6635 Telefax +37 2657 6602 www.wicona.com Czech Republic: Hydro Building Systems spol. s r.o. Spielberk Office Centre Holandská 8 CZ-63900 Brno Phone +420 (0) 543 422030 Fax +420 (0) 543 250168 www.wicona.cz Serbia: Hydro Building Systems d.o.o. Bulevar Zorana Đindića 105/4 RS-11070 Novi Beograd Phone +381 (0) 11 3130695 Fax +381 (0) 11 3130695 www.wicona.at Sweden: Hydro Building Systems AB Box 120 SE-360 70 Åseda Phone +46 474 48080 Telefax +46 474 10215 www.wicona.se Poland: Hydro Building Systems Sp. z o.o. ul. Mińska 63A PL - 03-828 Warszawa Phone +48 22 3308170 Telefax +48 22 3308171 www.wicona.com Hungary: Hydro Building Systems Kft. Graphisoft Park, Záhony u 7 H-1031 Budapest Phone +36 (1) 4533457 Fax +36 (1) 4533459 www.wicona.at Norway: Hydro Building Systems AB Drammensveien 260 NO-0283 Oslo Phone +47 22 422200 Telefax +47 94 771222 www.wicona.no Russia: ООО Гидро Билдинг Системс RUS-123317, Россия, Москва ул. Тестовская, д. 10 «Москва-Сити» БЦ «Северная башня» Тел. +7 917 5659559 www.wicona.ru Bulgaria: Hydro Building Systems EOOD “Bellissimo”, 102 Bulgaria Boulevard Et. 8, Ap. 10, P.O. Box 3 BG-1680 Sofia Phone +359 (2) 4903019 Fax +359 (2) 4903018 www.wicona.at Switzerland: Hydro Building Systems AG Gewerbepark Postfach 30 CH-5506 Mägenwil Phone +41 62 88741-41 Telefax +41 62 88741-11 www.wicona.ch 2510/01112120 Denmark: Salgskontor Danmark Hydro Building Systems Erhvervsparken 6 DK-8400 Ebeltoft Phone + 45 7020 2048 Telefax + 45 7020 2049 www.wicona.dk Romania: Hydro Building Systems S.R.L. Str. Nerva Traian nr. 1 Bloc K6, sc.1, et.1, ap.2, sector 3 RO-031041 Bucuresti Phone +40 (0) 21 3260045 Fax +40 (0) 21 3264175 www.wicona.at Croatia: Hydro Building Systems d.o.o. Ljudevita Posavskog 29 HR-10360 Sesvete Phone +385 (0) 12014800 Fax +385 (0) 12014801 www.wicona.at WICONA is a Hydro brand I D E A S