STICK SYSTEM FAÇADES
Name / series
Main advantages
■■
Passive house curtain wall
Structural glazing curtain wall
SG Design with
integrated pressure profile
4
Basic series for individual
adaptations according to the
WICONA Unisys technology
■■
Sight line 50 mm
■■
Profile depth 50 – 260 mm
■■
Infill thickness 3 – 63 mm
■■
Certified passive house
component (ift)
Applications / opening types
Performance features
■■
Curtain wall
■■
Uf until 1.2 W / (m2K)
■■
Glass roof constructions
■■
Sound insulation until 47 dB
■■
3D spatial constructions
(Polygonal façades up to 45°)
■■
■■
Curtain wall
■■
Polygonal façades up to 5°
Special functions
■■
Burglar resistance in class
WK1, WK2, WK3
System tests according to
DIN EN 13830 for CE marking
■■
Bullet resistance in class FB4
■■
Integrated sunshade
(special guide rails in
external cover profiles)
■■
Uf until 0.74 W / (m2K)
■■
■■
Uw Passive house < 0.8 W / (m K)
Burglar resistance in class
WK1, WK2
■■
System tests according to
DIN EN 13830 for CE marking
■■
Opening units in all-glass design:
see integration sashes
■■
Burglar resistance in class WK1
2
■■
Profile depth 50 – 260 mm
■■
Infill thickness 24 – 51 mm
■■
WICTEC 50 with complementary
special insulation profile
■■
SG structural glazing technology
■■
Curtain wall
■■
Uf until 1.5 W / (m2K)
■■
On the basis of WICTEC 50
■■
Glass roof constructions
■■
■■
With European Approval ETA
■■
Semi façades
(combined with pressure profiles)
System tests according to
DIN EN 13830 for CE marking
■■
Integrated pressure profiles,
overlying or flush to glass
■■
■■
System tests according to
DIN EN 13830 for CE marking
■■
No SG-approval required
Curtain wall with optical
characteristics of a
Structural glazing SG façade
■■
Profile width 43 or 51 mm
Section drawing
STICK SYSTEM FAÇADES
Name / series
Main advantages
■■
Add-on construction
for steel or wood
Mullion / mullion curtain wall
Fire protection
System for direct glazing on
structures made from customary
steel of wood profiles
■■
Sight line 50 mm
■■
Sealing and tightness assured
by a continuous gasket
■■
Stick system with identical profiles
for mullion and transom
Applications / opening types
Performance features
■■
Curtain wall
■■
Uf until 1.2 W / (m2K)
■■
Glass roof constructions
■■
System tests according to
DIN EN 13830 for CE marking
■■
Curtain wall
■■
Uf until 1.2 W / (m2K)
■■
System tests according to
DIN EN 13830 for CE marking
■■
Straight profile cut,
no notching required
■■
Sealing and tightness assured
by a continuous gasket
■■
Fire protection curtain wall
■■
Curtain wall
■■
Uf until 1.4 W / (m2K)
■■
For glazing or panels up to
1.8 x 3.0 m or 2.4 x 1.4 m
■■
Overhead glazing until 0° slope
■■
■■
Polygonal constructions up to 5°
System tests according to
DIN EN 13830 for CE marking
■■
With several national
general approvals
Special functions
■■
Burglar resistance in class
WK1, WK2
■■
Burglar resistance in class
WK1, WK2
■■
Fire resistance in class G30 / F30
Section drawing
5
STICK SYSTEM FAÇADES
Name / series
Main advantages
■■
Fire protection
Fire protection parapet
6
Basic series for individual
adaptations according to the
WICONA Unisys technology
Applications / opening types
Performance features
■■
Curtain wall
■■
Uf until 1.2 W / (m2K)
■■
Glass roof constructions
■■
Sound insulation until 47 dB
■■
3D spatial constructions
■■
Special functions
■■
Burglar resistance in class
WK1, WK2, WK3
System tests according to
DIN EN 13830 for CE marking
■■
Bullet resistance in class FB4
■■
Fire resistance in class G30 / F30
■■
Sight line 60 mm
■■
Profile depth 70 – 170 mm
■■
Infill thickness 3 – 51 mm
■■
Fire protection curtain wall
■■
Curtain wall
■■
Uf until 1.4 W / (m2K)
■■
For glazing or panels up to
1.8 x 3.0 m or 2.4 x 1.4 m
■■
Overhead glazing until 0° slope
■■
System tests according to
DIN EN 13830 for CE marking
■■
With several national
general approvals
■■
Fire protection class W90
■■
■■
Exterior layer in glass
or aluminium
Integration in stick curtain
walls to prevent flash over
of fire from storey to storey
Section drawing
U N I T I Z E D F açades
Name / series
Main advantages
■■
Unitized curtain wall on
stick system base
■■
Exterior glazing beads
with mitre cut, leading to
a picture frame design
■■
Sight lines 50 / 65 mm
■■
Exterior glazing beads
with mitre cut, leading to
a picture frame design
■■
Applications / opening types
■■
Unitized curtain wall for complete
pre-assembly in the workshop,
including glazing and parapet
elements
■■
Unit size until 3.5 m height
and 3.0 m width (storey height)
■■
Unitized curtain wall for complete
pre-assembly in the workshop,
including glazing and parapet
elements
Sight line 60 mm
■■
Performance features
■■
Uf until 1.4 W / (m2K)
■■
System tests according to
DIN EN 13830 for CE marking
■■
Uf until 1.6 W / (m2K)
■■
System tests according to
DIN EN 13830 for CE marking
Special functions
Section drawing
Unit size until 3.5 m height
and 2.8 m width (storey height)
7
I N T E G R AT I O N S A S H E S
Name / series
Roof light vent sash
Lowering and projecting
top-hung window SG
Main advantages
■■
Sight line 81 mm
■■
Concealed hinges with
opening angle 90°
■■
■■
■■
Applications / opening types
■■
Application in WICTEC 50 / 60
glass roof constructions until
10° slope
Glass level offset only 36 mm
■■
Sash size until 1.4 x 1.8 m
or 1.8 x 1.4 m
Outward opening sashes in
Structural Glazing SG Design
■■
Lowering and projecting
top-hung window size until
1.5 x 2.5 m or 2.0 x 1.5 m
For manual or motorized operation
■■
Parallel outward opening
sash size until 1.5 x 3.0 m
or 2.0 x 1.5 m
■■
Inward opening:
Turn-tilt, turn, tilt, tilt-first,
double casement
Parallel outward opening
window SG
■■
Complete system advantages
of the comprehensive
WICLINE evo window series
■■
See windows
Performance features
■■
System tests according to
DIN EN 14351-1 for CE marking
■■
Uf until 1.6 W / (m2K)
■■
System tests according to
DIN EN 14351-1 for CE marking
■■
Uf until 1.4 W / (m2K)
■■
Uw until 1.2 W / (m2K)
■■
System tests according to
DIN EN 14351-1 for CE marking
Outward opening:
Top-hung, Italian,
pivot (horizontal / vertical)
Special functions
■■
NSHE (Natural smoke and
heat exhaust ventilators)
■■
Glazing with pressure profile
or spot holder
■■
Application in WICTEC 50SG
Structural glazing curtain wall
or in WICTEC 50 curtain
wall with pressure profiles
■■
Burglar resistance in class
WK1, WK2, WK3
■■
Concealed sash
■■
Classic design
Section drawing
Example shown: concealed sash
■■
Ventilation flap
8
Slim opening sash for
manual ventilation
■■
Width 250 mm
■■
Height until 2.25 m
■■
Turn sash made of only one
thermally broken aluminium profile
■■
Uf until 1.6 W / (m2K)
■■
Sound insulation until 41 dB
■■
Sound insulation in open position
until 21 dB resp. 26 dB depending
on the ventilation type
WINDOWS
Name / series
Main advantages
■■
■■
Profile depth 65 mm
■■
Infill thickness 3 – 60 mm
■■
Fittings concealed or visible,
until 160 kg sash weight
■■
Minergie-P Module window
Basic series for individual
adaptations according to the
WICONA Unisys technology
■■
Profile depth 65 mm
■■
Infill thickness 6 – 70 mm
■■
Fittings concealed or visible,
until 160 kg sash weight
■■
Certified according to the
Swiss Minergie-P Standard
■■
Profile depth 85 mm
■■
Slim frame construction,
no visible sash frame
■■
Concealed sash
Basic series for individual
adaptations according to the
WICONA Unisys technology
Profile depth 75 / 85 mm
Applications / opening types
■■
■■
■■
Inward opening:
Turn-tilt, turn, tilt, tilt-first,
double casement, fanlight,
parallel sliding / tilt,
French window (window-door)
Performance features
■■
Uf until 1.4 W / (m2K)
■■
Uw until 1.2 W / (m2K)
■■
System tests according to
DIN EN 14351-1 for CE marking
Outward opening:
Top-hung, Italian, French,
pivot (horizontal / vertical)
Inward opening:
Turn-tilt, turn, tilt, tilt-first,
double casement, fanlight,
parallel sliding / tilt,
French window (window-door)
■■
Outward opening:
Top-hung, Italian, French,
pivot (horizontal / vertical)
■■
Double Casement turn window
■■
Turn-tilt, with overlapping sash
■■
Inward opening:
Turn-tilt, turn, tilt-first,
double casement, fanlight
■■
Uf until 1.2 W / (m2K)
■■
Uw until 0.9 W / (m K)
■■
System tests according to
DIN EN 14351-1 for CE marking
Special functions
■■
Burglar resistance in class
WK1, WK2, WK3 and
RC1, RC2, RC3
■■
Bullet resistance*
■■
Integration in stick system
curtain walls
■■
Minergie window (according to
Swiss Minergie standard)
■■
Burglar resistance in class
WK1, WK2, WK3 and
RC1, RC2, RC3
■■
Bullet resistance*
■■
Integration in stick system
curtain walls
■■
Burglar resistance in class
WK1, WK2, WK3 and
RC1, RC2, RC3
■■
Integration in stick system
curtain walls
2
■■
Uw according to Minergie-P
specification < 0,8 W / (m2K)
■■
Uf until 1.8 W / (m2K)
■■
Uw until 1.0 W / (m K)
■■
System tests according to
DIN EN 14351-1 for CE marking
2
* In preparation
Section drawing
9
WINDOWS
Name / series
Main advantages
■■
Classic design
French window (window-door),
barrier free
Industry design
10
Performance features
■■
Turn
■■
Uf until 1.2 W / (m2K)
■■
Turn-tilt
■■
Uw until 0.9 W / (m2K)
■■
System tests according to
DIN EN 14351-1 for CE marking
■■
Profile depth 75 / 85 mm
■■
Double casement
■■
Fittings concealed or visible,
until 160 kg sash weight
■■
Tilt-first
■■
Fanlight
■■
Opening inward or outward
■■
Turn
■■
Uf until 1.3 W / (m2K)
■■
With barrier free threshold
■■
Turn-tilt
■■
Uw until 0.9 W / (m2K)
■■
Sash size until 1.70 x 2.50 m
■■
Double casement
■■
■■
Lockable
■■
Tilt-first
System tests according to
DIN EN 14351-1 for CE marking
■■
Profile contours of classical
steel window profiles
■■
Turn
■■
■■
Turn-tilt
System tests according to
DIN EN 14351-1 for CE marking
■■
Ideal for renovations
■■
Double casement
■■
Profile depth 77 mm
■■
Tilt-first
■■
Fanlight
■■
Turn
■■
Turn-tilt
■■
Double casement
■■
Tilt-first
■■
Fanlight
■■
French window (window -door)
■■
Non-insulated
30° bevelled profiles
with overlapping sash
Applications / opening types
■■
Non-insulated profiles
for interior application
Profile depth 65 mm
Special functions
■■
Burglar resistance in class
WK1, WK2, WK3 and
RC1, RC2, RC3
■■
Integration in stick system
curtain walls
■■
Burglar resistance in class
WK1, WK2, WK3
Section drawing
WINDOWS
Name / series
Main advantages
■■
Coupled window
■■
■■
Hybrid window
Coupled window with
additional connected sash
Applications / opening types
Performance features
■■
Turn
■■
Uw until 0.9 W / (m2K)
■■
Turn-tilt
■■
Sound insulation until
48 (-2 / -5) dB
■■
System tests according to
DIN EN 14351-1 for CE marking
Improved thermal and
sound insulation
Profile depth 125 mm
■■
Window with Hybrid technology
■■
Double skin design with
2 sash types
■■
Improved thermal and
acoustic insulation
■■
Profile depth 215 mm
■■
Optimized user comfort
■■
■■
Interior sash:
turn, turn-tilt
Exterior sash:
Parallel outward opening
with motor operation
■■
Uw until 0.65 W / (m2K)
■■
Sound insulation until 57 dB
Special functions
■■
Burglar resistance in class
WK1, WK2, WK3
■■
Exterior sash can be with single
or double glazing, concealed, with
industry design or in SG structural
glazing technology
■■
Sun protection device can be
integrated between the sashes
■■
Sun protection device can be
integrated between the sashes
■■
Automatic operation for
night cooling
Section drawing
11
DOORS
Name / series
Main advantages
■■
■■
Profile depth 65 mm
■■
Infill thickness 2 – 50 mm
■■
Sash weight until 200 kg
■■
Possible in Classic design with
30° bevelled profile contour
■■
Single and double leaf hinged door
■■
Uf until 1.8 W / (m2K)
■■
Inward and outward opening
■■
Sound insulation until 43 dB
■■
Push-pull door*
■■
■■
Finger protection door*
System tests according to
DIN EN 14351-1 for CE marking
■■
All-glass door*
■■
Single action doors*
■■
Fixed and movable lateral parts
■■
Fanlight
■■
Single and double leaf
hinged door
■■
Uf until 1.6 W / (m2K)
■■
Uw until below 0.8 W / (m K)
Special functions
■■
Burglar resistance in class
WK1, WK2, WK3
■■
Integration in stick system
curtain walls
■■
Panic function according to
DIN EN 179 / 1125
■■
Leaf overlapping infill (single
or double side) on demand
■■
Burglar resistance in class
WK1, WK2, WK3
■■
Integration in stick system
curtain walls
2
■■
Inward and outward opening
■■
Sound insulation until 43 dB
■■
System tests according to
DIN EN 14351-1 for CE marking
■■
Leaf overlapping infill (single
or double side) on demand
■■
Uf until 2.1 W / (m2K)
■■
■■
Sound insulation until 42 dB
Burglar resistance in class
WK1, WK2, WK3
■■
System tests according to
DIN EN 14351-1 for CE marking
Profile depth 75 mm
■■
Push-pull door
■■
Infill thickness 3 – 60 mm
■■
Finger protection door
■■
Sash weight until 200 kg
■■
Push-pull doors
■■
Possible in Classic design with
30° bevelled profile contour
■■
Fixed and movable lateral parts
■■
Fanlight
Entrance door system with
individual execution options
■■
Single and double leaf
hinged door
Profile depth 88 mm
■■
Inward and outward opening
■■
Fixed and movable lateral parts
■■
Fanlight
■■
12
Basic series for individual
adaptations according to the
WICONA Unisys technology
Performance features
■■
■■
■■
Non-insulated
Basic series for individual
adaptations according to the
WICONA Unisys technology
Applications / opening types
■■
Non-insulated profiles
for interior application
■■
Single and double leaf
hinged door
■■
Profile depth 50 mm
■■
Inward and outward opening
■■
Fixed and movable lateral parts
■■
Fanlight
* In preparation
Section drawing
DOORS
Name / series
Main advantages
■■
Non-insulated
Fire protection door
■■
Profile depth 65 mm
■■
Single and double leaf hinged door
■■
Inward and outward opening
■■
Fixed and movable lateral parts
■■
Bullet resistance in class FB4
■■
Fanlight
■■
■■
Single action door
Panic function according to
DIN EN 179 / 1125
■■
Finger protection door
■■
■■
All-glass door
Smoke protection in
Class RS1, RS2
■■
Fire protection in class
EI30 / T30 / F30
■■
With additional insertion
strips in class EI60 / T60
■■
Panic function according to
DIN EN 179 / 1125
■■
Smoke protection
■■
Special functions depending
on national regulations
■■
Multiple fittings and lock options
Fire protection door
■■
Single and double leaf hinged door
Profile depth 77 mm
■■
Inward and outward opening
■■
Fixed and movable lateral parts
■■
Fanlight
■■
For interior application
■■
Profile depth 100 mm
■■
Tested as complete system
(with drive unit) according to
DIN EN 14351-1
Automatic sliding door
■■
Sash size until 2.0 x 3.0 m
■■
Single and double leaf hinged door
■■
Inward and outward opening
■■
■■
■■
Fanlight
■■
■■
System tests according to
DIN EN 14351-1 for CE marking
Special functions
Burglar resistance in class
WK1, WK2
■■
Fire protection system
ready-to-install
Performance features
■■
■■
■■
Fire protection door
Non-insulated profiles for
interior application
Applications / opening types
System tests according to
DIN EN 14351-1 for CE marking
■■
Fire protection in class T90 / F90
Single and double leaf sliding door
■■
Ud until below 1.5 W/m2K
Fixed and movable lateral parts
■■
System tests according to
DIN EN 14351-1 for CE marking
Section drawing
13
SLIDING SYSTEMS
Name / series
Main advantages
Performance features
■■
Circumferential outer frame
■■
Lifting sliding door
■■
Uw < 1.0 W / (m2K)
■■
Construction depth 160 mm
(double track)
■■
Double track
■■
■■
Sliding or fixed sash
System tests according to
DIN EN 14351-1 for CE marking
■■
Sash size until 3.24 x 3.4 m
■■
Construction depth
160 mm (double track) or
240 mm (triple track)
■■
Lifting sliding door / window,
sliding door / window
■■
Uw < 1.3 W / (m2K)
■■
System tests according to
DIN EN 14351-1 for CE marking
■■
Double or triple track
■■
Sash depth 60 mm
■■
Fixed sash
■■
Sash size until 2.41 x 2.5 m
■■
2 to 6 leaves
■■
Construction depth
105 mm (double track) or
160 mm (triple track)
■■
Lifting sliding door / window,
sliding door / window
■■
Double or triple track
■■
Sash depth 40 mm
■■
Fixed sash
■■
Sash size until 2.1 x 2.45 m
■■
2 to 6 leaves
■■
Construction depth
50 mm (double track) or
92 mm (triple track)
■■
Sliding door / window
■■
Double or triple track
■■
Fixed sash
■■
2 to 6 leaves
■■
14
Applications / opening types
Sash depth 34 mm
■■
Uw < 1.6 W / (m2K)
■■
System tests according to
DIN EN 14351-1 for CE marking
Special functions
■■
Integration in stick
system constructions
■■
Burglar resistance in class
WK1, WK2
■■
Integration in stick
system constructions
■■
Burglar resistance in class
WK1, WK2
■■
Integration in stick system
constructions
Section drawing
SLIDING SYSTEMS
Name / series
Main advantages
■■
■■
Non-insulated profiles for
interior application
Construction depth
50 mm (double track) or
92 mm (triple track)
■■
Sash 34 mm
■■
Folding sliding system with partition
to the right or to the left
■■
Applications / opening types
Performance features
■■
Sliding door / window
■■
Double or triple track
■■
Fixed sash
■■
2 to 6 leaves
■■
Folding sliding door
■■
Uw until 1.3 W / (m2K)
■■
With single or double
casement sash
■■
System tests according to
DIN EN 14351-1 for CE marking
■■
Turn or turn-tilt opening
■■
2 to 7 leaves
Inward and outward opening
Special functions
■■
Section drawing
Low threshold for
barrier free access
15
T E C H N O L O G Y
F O R
WICONA series
Germany:
Hydro Building Systems GmbH
Söflinger Straße 70
D-89077 Ulm
Phone +49 731 3984-0
Telefax +49 731 3984-241
www.wicona.de
Austria:
Hydro Building Systems GmbH
Wallerseestrasse 49
A-5201 Seekirchen Phone +43 (0) 6212 2000
Fax
+43 (0) 6212 20236
www.wicona.at
Slovenia:
Hydro Building Systems GmbH
Kozjak nad Pesnico 34b
SLO-2201 Zg. Kungota Phone +386 (0) 26 209970
Fax
+386 (0) 26 209218
www.wicona.at
Estonia / Latvia / Lithuania:
Hydro Building Systems OÜ
Pärnu mnt. 139 f
EST-11317, Tallinn
Phone +37 2657 6635
Telefax +37 2657 6602
www.wicona.com
Czech Republic:
Hydro Building Systems spol. s r.o.
Spielberk Office Centre
Holandská 8
CZ-63900 Brno
Phone +420 (0) 543 422030
Fax
+420 (0) 543 250168
www.wicona.cz
Serbia:
Hydro Building Systems d.o.o.
Bulevar Zorana Đindića 105/4
RS-11070 Novi Beograd
Phone +381 (0) 11 3130695
Fax
+381 (0) 11 3130695
www.wicona.at
Sweden:
Hydro Building Systems AB
Box 120
SE-360 70 Åseda
Phone +46 474 48080
Telefax +46 474 10215
www.wicona.se
Poland:
Hydro Building Systems Sp. z o.o.
ul. Mińska 63A
PL - 03-828 Warszawa
Phone +48 22 3308170
Telefax +48 22 3308171
www.wicona.com
Hungary:
Hydro Building Systems Kft.
Graphisoft Park, Záhony u 7
H-1031 Budapest
Phone +36 (1) 4533457
Fax
+36 (1) 4533459
www.wicona.at
Norway:
Hydro Building Systems AB
Drammensveien 260
NO-0283 Oslo
Phone +47 22 422200
Telefax +47 94 771222
www.wicona.no
Russia:
ООО Гидро Билдинг Системс
RUS-123317, Россия, Москва
ул. Тестовская, д. 10
«Москва-Сити»
БЦ «Северная башня»
Тел. +7 917 5659559
www.wicona.ru
Bulgaria:
Hydro Building Systems EOOD
“Bellissimo”, 102 Bulgaria Boulevard
Et. 8, Ap. 10, P.O. Box 3
BG-1680 Sofia Phone +359 (2) 4903019
Fax
+359 (2) 4903018
www.wicona.at
Switzerland:
Hydro Building Systems AG
Gewerbepark
Postfach 30
CH-5506 Mägenwil
Phone +41 62 88741-41
Telefax +41 62 88741-11
www.wicona.ch
2510/01112120
Denmark:
Salgskontor Danmark
Hydro Building Systems
Erhvervsparken 6
DK-8400 Ebeltoft
Phone + 45 7020 2048
Telefax + 45 7020 2049
www.wicona.dk
Romania:
Hydro Building Systems S.R.L.
Str. Nerva Traian nr. 1
Bloc K6, sc.1, et.1, ap.2, sector 3
RO-031041 Bucuresti Phone +40 (0) 21 3260045
Fax
+40 (0) 21 3264175
www.wicona.at
Croatia:
Hydro Building Systems d.o.o.
Ljudevita Posavskog 29
HR-10360 Sesvete
Phone +385 (0) 12014800
Fax
+385 (0) 12014801
www.wicona.at
WICONA is a Hydro brand
I D E A S