Vitrina Ácidos fuertes - Premium EN
Transcription
Vitrina Ácidos fuertes - Premium EN
PE DE O · M A · MA I N E UR O PE DE IN E U R FUME HOOD FOR STRONG AND HYDROFLUORICS ACIDS PREMIUM Fume hood with work surface for strong and hydrofluoric acids. Designed and manufactured in compliance with the requirements of European standards EN 14175-7. The internal cabin is manufactured in polypropylene (including service nozzles with the exception of LPG Gas), providing excellent chemical resistance in the daily use of strong acids. Transparent methacrylate sash available when using hydrofluoric acid . It can optionally be equipped with a panel washing system, to prevent acid crystallization in non-accessible sections at the rear part of the cabin. The range of sizes, optional features and various operating options with constant or variable air flow, means that the fume hood can be configured in a completely flexible way. The ease of use, accessibility, lighting, sash and protection system which prevents any possible explosions provides a very high degree of passive user safety. It features a condensation collection system in the air inlet duct. Models External dimensions Internal dimensions Width Depth Height Internal width Internal depth Internal height VA120960AC A 1200 C 960 2500 B 1080 E 665 D 755 1200 VA150960AC 1500 960 2500 1380 665 755 1200 VA180960AC 1800 960 2500 1680 665 755 1200 VA210960AC 2100 960 2500 1980 665 755 1200 Under cabinets: Standard, acid and alkali cabinets available in 600 and 900 mm to be fitted under the C-frame. Fireproof cabinets also available. PE DE O · M A · MA I N E UR O PE EN 14175 DE IN E U R FUME HOOD FOR STRONG AND HYDROFLUORICS ACIDS | PREMIUM WORKTOPS SASHES Ceramic: Chemically work surface resistant to acids as per the standard DIN 51102 (not recommended for hydrofluoric acids). Epoxy resin: NSF/ANSI51 certified solid epoxy resin. Polypropylene: 10 mm thick in working area Motorized or manual. Material: 6 mm safety glass 6 mm methacrylate (recommended for hydrofluoric acids). Types: Fixed or fixed + sliding windows. CONTROL SYSTEM CONTROL SYSTEM SG: EN 14175 parts 2 and 3 safety and control system. Motor ON/OFF switch. Lighting ON/OFF switch. Airflow visual indicator. Visual and acoustic airflow interruption alarm. Visual and acoustic overheating alarm in the event of overheating inside the hood. Over opening sash visual and acoustic alert. Fume hood information display. SAI system control panel alerts of any power supply outage. Internal temperature sensor with two set points. Analog hood status outputs. VAV: Variable Air Volume safety and control system that contributes to enhance efficiency and savings while ensures user safety EN 14175 parts 2, 3 and 6. All SG system functions. Motorized damper airflow control. Vmax function: ensures maximum airflow regardless of the sash position. Analog output to control the motor speed inverter. Pre-programmed airflow configuration. Analog output for room compensating functions. Optional digital connection for BMS control with BACnet or LON. ELECTRICAL POWER CONNECTIONS LIGHTING "Schuko“: CEE 7/4 Type F, 10/16A IP-44. ^ British: BS 1363 Type G, 13A IP-44. USA: NEMA 5-15 Type B, 15A IP-44. Others: available on request. Internal lighting: over 500 lux. Protection standard: IP 65. Optional: Emergency lighting with SAI system. Electrical protection: Comfort Acoustic System: Services: Accessories: Circuit breaker (MCB) for the fume hood installation (sockets, control system and lighting) and an optional differential switch. Includes an innovative noise attenuation system, offering maximum comfort, ergonomics and safety to the user. Noise level guaranteed not to exceed NR43 for pressures of approx. 500 Pa. (Optional according to installation). Fume hood is equipped with a wide range of taps and pressure gauges with internal polypropylene nozzles as per standard DIN-13792. Also comes with flexible tubes to ease the fume hood installation. A wide range of accessories is available: Fume hood is equipped with an electronic device to protect the fan. Panel washing system Air flow ducts for under cabinets Waste collection system, etc. Fire extinguisher system, etc. Effect of the face velocity (Extraction volume as per standard EN 14175-3 robustness and containment of 1.5 meter-wide fume hood VA150960). Air flow diagram: Open sash and closed sash. Open sash Calle Lanzarote 11, Nave 8 28700 San Sebastián de los Reyes, Madrid. [email protected] Tel.+34 91 659 15 06 | Fax. +34 91 653 09 57 www.fvhoods.com Closed sash