Automatic Pool Cover Builders Guide for Gunite Pools (Specialized)
Transcription
Automatic Pool Cover Builders Guide for Gunite Pools (Specialized)
Coverstar East Coast, Inc. Maryland Branch 1704 Back Acre Circle Mount Airy, MD 21771 Office: 800-870-3329 Fax: 301-829-6866 Pennsylvania Branch 207 Crothers Road Rising Sun, Maryland 21911 Office: 866-801-7538 Fax: 410-658-7632 Connecticut Branch 196 East Main Street. Thomaston, CT 06787 Office: 866-746-8444 Fax: 866-799-4911 Automatic Pool Cover Builders Guide for Gunite Pools (Specialized) Gunite Table of Contents (Specialized) 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. Auto Cover Installation Process Flowchart Underguide Specs – Condensed Underguide Gunite Encapsulation 110 V AC Wiring Diagram CS-1800 Hydraulic Specifications Underguide Gunite Specs – Condensed 220 V Hydraulic Concrete Cover Box Top View Coping Overhang Detail Coping Overhang Detail – Gunite Encapsulated Guide Box Detail Aluminum Lid with Pavers Concrete Box Detail Stone Lid with Poured Deck Walk-on Lid Details Mirrored Walk-on Lid Details Stone Lid Installation Policy Stone Lid Brackets Steel Detail Stainless Steel Brackets Detail Concrete Cover Box with Brick Tray and Pavers Concrete Box Detail – Hidden Leading Edge Stone Lid Layout for Hidden Leading Edge Pool in Pool with Hidden Leading Edge Raised Wall Detail for Cover Housing Raised Side Spa Detail Vanishing Edge Top guide Detail Pool and Product Specifications for Vanishing Edge Negative Edge Detail Non-Motor End Negative Edge Option 1 Vanishing Edge on Mechanism End Extreme Cantilever Forming Extreme Cantilever Concrete Cover Box Detail for CS300 Auto-Spa Cover Box Detail with Stone Lid and Poured Deck Auto-Spa 3-Wire Motor with Circuit and Feature Board Motorized Cover Winter Use Policy Slack in Automatic Pool Covers Warranty Summary UL and ASTM Standard Motorized Cover Installation Readiness Checklist COVERSTAR AUTO COVER INSTALLATION PROCESS CONCRETE POOLS • • BUILDER NOTIFY CSEC OF JOB. (USE ORDER INFO. FORM) GENERAL NOTES: CSEC = COVERSTAR EAST COAST, INC. NOTIFY CSEC: NOTIFY AREA COORDINATOR PREFERRABLY BY EMAIL. BUILDER NOTIFY CSEC TO INSTALL ENCAPS. & PRESITE BUILDER RESPONSIBILTY CSEC RESPONSIBILTY YES CSEC SCHEDULE REMOVE FORM BUILDER PROVIDE CSEC DEPOSIT & CONTRACT BUILDER DIG POOL BUILDER SET TILE NO TILE & COPING NOTES: • BOTH TILE & COPING NEED TO BE DONE TO PRESITE POOL. • • DIG NOTES: EXCAVATE AREA FOR BOX. DIG AREA FOR DRAIN W/PROPER ELEVATION NOTIFY CSEC POOL HAS BEEN SHOT CSEC SCHEDULE SET FORM OR POLY BOX BUILDER SET STEEL BULDER INSTALL PLUMBING & ELECTRICAL CSEC SCHEDULE PRESITE CSEC ORDER COVER • PLUMBING NOTES: INSTALL COVER BOX DRAIN TO OPEN AIR. P:\Technical Information & Drawings\Builder Spec Books\2011 Builder Book Rebuild\Originals\Gunite-Specialized\FLOW CHART - CONCRETE.doc CSEC ORDER COVER BUILDER SET COPING BUILDER PLASTER & FILL POLL W/WATER BUILDER SET COPING BUILDER NOTIFY CSEC TILE & COPING IS DONE BUILDER SHOOT POOL BUILDER NOTIFY CSEC POOL HAS BEEN DUG IS POOL GETTING ENCAPSILATION? CSEC SCHEDULE PHASE 1 INSTALLATION & PRESITE BUILDER PLASTER & FILL POOL w/WATER BUILDER NOTIFY CSEC POOL IS READY FOR COVER CSEC SCHEDULE TO INSTALL COVER BUILDER NOTIFY CSEC POOL IS READY FOR COVER ECLIPSE™ UNDERGUIDE – GUNITE ENCAPSULATION 110VAC Model Only A Square Corners Maximum of ¾” cantilever both sides. 3/4” (max.) ½” Mortar Bed Encapsulation B General Requirements 1. Pool must be a true rectangle. (ABCD AB=CD, AC=BD, AD=BC 2. Mechanism end bond beam and any interior walls 2 inches lower. 3. Deck around perimeter of pool must have 3/4 inch maximum cantilever. 4. One 3 inch drain from housing required. Adequate housing drainage required. Excavation 1. Layout must be pure rectangle and corners must be cut square. 2. Skimmers may be either side or on end opposite the mechanism. 3. Dig housing area shelf 18” below top of side wall bond beams. 4. Shallow end dig is best with housing at deep end. (Less foot traffic). Cover Housing 1. Install after excavation and before steel. 2. Interior bottom of housing is 14” below side bond beam elevation. 3. Stake housing in place. Housing must not be moved after installation. 4. Motor end offset is 36” and non-motor end offset is 12” from inside water wall. 5. Housing is 14” wide and 14” deeper than side wall bond beam elevation for pools up to 55’ long. For longer pools contact your Coverstar distributor. Steel 1. All corners are square. 2. Steel the housing end bond beam and any interior spa walls 2 inches lower. Plumbing 1. Plumbing should be kept 16 inches lower than side wall elevation in housing area. 2. 3 inch drain required at motor end of housing. Non-motor end drain is optional but best. Avoid placing plumbing pipes under housing. Place drains tight to edge of box. Electrical 1. #8 solid bond wire with 3’ tail on each end of box. Wire must be bonded to equipment pad. 2. Full load motor amps 8.5, 110 VAC. Use adequate wire size. Follow all required codes. 3. Wire to housing should end in all-weather box. Standard system requires all wires to be sized for motor rating. Key switch carries full motor amperage. 4. Key switch requires a standard box. It must be located where 100% of pool surface is visible. Gunite 1. Pool must be a true rectangle. AB=CD, AC=BD, and AD=BC 2. Mechanism end bond beam is lowered 2 inches between side wall bond beams. 3. Interior spa walls lowered 2 inches. 4. All corners cut square. Cantilevered Edge 1. Cantilevered edge must finish no more than 3/4 inches after tile on both long sides. Tile 1. Tile top of lowered bond beam. Tile should finish 1 1/2 inches below the underside of the deck edge and slope ½ inch toward pool. 2. Interior spa walls must finish 2 inches below bottom of cantilevered edge with no rough edges. Cover Installation 1. Cover must be installed after water is in the pool. 2. In no case may cover be left over the pool without water level in pool at final elevation. Tile 36” 3” Drain 12” Lowered Bond Beam C Minimum of 2” lower than side bond beam D Standard inside housing for pools up to 55’ long 14” Wide 14” Deep (from side bond beam elevation) Bond Wire Motor Location Electrical: Units require ½“ single gang all-weather box 3” Drain Non-Motor End X Note: To determine motor side for ordering, stand at the “x” looking the direction of the arrow. Which side is the motor on? (Left hand motor shown) 110V. WIRING DIAGRAM FOR 3 WIRE MOTOR USING LEVITON SWITCH NOTES: POWER SUPPLY 110VAC 15AMPGFCI TROUBLE SHOOTING TIPS * The control switch is mounted in a standard depth single gang box. COVERSTAR 3 WIRE MOTOR * Motor connections are made in an all-weather box mounted as high as possible in the cover box. (NEUTRAL, 2 DIRECTIONALS, AND GROUND) * The control switch must be mounted in a location where 100% of the pool surface is visible. L1 WHITE RED BLUE BLUE CONTROL SWITCH STANDARD ALL-WEATHER BOX* NOTES: ( THEN CHECK THE FOLLOWING) * Disconnect wires from the switch and test for continuity, you should have continuity between L1 and A1 when you toggle the switch in one direction and between L1 and A2 in the other direction. (Do not attempt to run this test with wires connected to the switch, you will get false readings.) Conduit boxes & wiring supplied by electrician A1 B1 * If the indicator light comes on in one direction but not the other, the problem is probably a connection either at the switch or in the junction box in the cover box. * If the indicator light comes on in both directions but the motor does not run at all, check the neutral wire and it’s connections. = WIRE NUT INDICATOR LIGHT (USING THE INDICATOR LIGHT * If the indicator light does not come on in either switch position, check the power supply for 110 v. ALL-WEATHER JUNCTION BOX* *Supplied by electrician * The HOT (black) wire from the power supply connects to the L1 terminal on the switch. * The NEUTRAL (white) wire from the power supply connects to the indicator light and also passes through to be connected at the motor conduit white wire. * The remaining wire on the indicator light connects to a directional terminal on the switch (A1 or A2). * Using a test cord, disconnect wires in the all weather box and connect the neutral wire to the white motor wire and connect the hot wire to the red motor wire. The motor should run. Then switch the hot wire over to the blue motor wire. The motor should run in the other direction. If the motor runs in both directions using this method, the trouble is in the components or wiring leading up to that point in the system. If the motor still does not run properly, you may need to investigate the capacitor inside the control box mounted on top of the motor. * The Red and Blue wires from the motor connect to the directional terminals on the switch. (A1 and A2) The red and blue wires may be switched with each other to change the motor direction. * The motor requires 8.5 amps and all wiring from the power supply to the motor must be si zed accordingly. * Use a 15amp GFCI breaker at the panel. * The motor capacitor is located inside the motor control compartment on top of the motor. REV. 4/03/2007 Coverstar Inc. 533 S. 500 W. Provo Ut. 84601 L0702 CS1800 HYDRAULIC SPECIFICATIONS The hydraulic system setup and installation is basically the same as the electric except for a few differences noted below. COVER BOX DIMENSIONS: The box will be the same size (12” x 12” up to 42 ‘. 32” motor end and 10” non-motor end), except that the motor end can be reduced to 28” instead of 32” CHASE: For recessed installations, a chase should be provided for the hydraulic hoses. This should be a minimum diameter of 2 inches, 3” preferable. The length can be any length that is necessary, as the power pack looses a very small amount of power over lengths of up to 250 feet. However, it is recommended that the chase be kept as short as possible because of problems in pulling the hoses and replacement costs in the event that the hose needs to be replaced. The most important aspect of installing the chase is to avoid any sharp bends. PAD FOR POWER PACK: 26" long x 10" wide x 10" high (Never place in box with mechanism) ELECTRICAL: We offer both 110 and 220 volt power packs, however we strongly recommend that 220 be used. See wiring diagrams for complete information. A 220 volt installation is rated at 14 amps, 110 volts draws 28 amps. INSTALLATION: The mechanism is exactly the same as the electric motor except that there is no torque limiter; therefore, the installation is the same. See the hydraulic installation instructions for complete instructions as to how to set up the power pack and make the necessary adjustments to the power pack. LIMIT SWITCHES: Normally limit switches are not necessary as the bypass valves can be set to act as limit switches. However, in some cases, it may be desirable to install optional electric limit switches to act as a back-up shutoff system. This is especially true where the cover is exceptionally large or is operating under a lot of stress because of deck drag. If untrained people will be operating the cover such as is the case with a homeowner’s association, it is also recommended that limit switches be installed. HYDRAULIC OIL: It is recommended that ISO 46 fluid or its equivalent be used. If not available, Dextron III may be used. P:\Technical Information & Drawings\Builder Spec Books\2011 Builder Book Rebuild\Originals\Gunite‐Specialized 02‐01‐11 ECLIPSE UNDERGUIDE GUNITE SPECS - Condensed HYDRAULIC ONLY – 220V A Square Corners 2 ½ “ Finished flat cantilever, both sides and pool end 2 ½ “ Flat Tile B General Requirements 1. Pool must be a true rectangle. (ABCD AB=CD, AC=BD, AD=BC 2. Gunite mechanism end bond beam and any interior walls 2 inches lower. 3. Deck around perimeter of pool must have 2 ½ inch minimum flat cantilever after tile. 4. One 3 inch drain from housing required. Adequate housing drainage required. Excavation 1. Layout must be pure rectangle and corners must be cut square. 2. Skimmers may be either side or on end opposite the mechanism. 3. Dig housing area shelf 18” below top of side wall bond beams. 4. Shallow end dig is best with housing at deep end. (Less foot traffic). Cover Housing 1. Install after excavation and before gunite. 2. Interior bottom of housing is 14” below side bond beam elevation. 3. Stake housing in place. Housing must not be moved after installation. 4. Motor end offset is 36” and non-motor end offset is 12” from inside water wall. 5. Housing is 14” wide and 14” deeper than side wall bond beam elevation for pools up to 55’ long. For longer pools contact your Coverstar distributor. Steel 1. All corners are square. 2. Steel the housing end bond beam and any interior spa walls 2 inches lower. Plumbing 1. Plumbing should be kept 16 inches lower than side wall elevation in housing area. 2. 3 inch drain required at motor end of housing. Non-motor end drain is optional but best. Avoid placing plumbing pipes under housing. Place drains tight to edge of box. 3. Run Minimum 2 ½ inch (3” best) chase (conduit) from cover box to power pack location for hoses. NO 90 degree bends. Electrical 1. #8 solid bond wire with 3’ tail on each end of box. Wire must be bonded to equipment pad. 2. Full load motor amps 14, 220 V. Four wires required, 2 hot plus neutral and ground. Use adequate wire size. Follow all required codes. See wiring diagram. 3. Power pack requires 12” by 30” mounting area on equipment pad. Power pack must be located on equipment room or ordered with optional housing for protection from the elements. 4. Key switch requires a standard box. It must be located where 100% of pool surface is visible. Gunite 1. Pool must be a true rectangle. AB=CD, AC=BD, and AD=BC 2. Mechanism end bond beam is lowered 2 inches between side wall bond beams. 3. Interior spa walls lowered 2 inches. 4. All corners cut square. Cantilevered Edge 1. Cantilevered edge must finish 2 ½ inches FLAT after tile on 3 sides 2. Deck edge material must be hard enough to hold a screw and anchor without cracking deck edge. Type and sufficiency is responsibility of deck contractor. Coverstar is not responsible for damage to deck edge from track mounting. 3. Continue cantilever over lowered bond beam to front (inside edge) of housing. Tile 1. Tile top of lowered bond beam. Tile should be 2 inches below the underside of the deck edge and slope ½ inch toward pool. 2. Interior spa walls must finish 2 inches below bottom of cantilevered edge with no rough edges. Cover Installation 1. Cover must be installed after water is in the pool. 2. In no case may cover be left over the pool without water level in pool at final elevation. 30” 3” Drain 12” Lowered Bond Beam C Minimum of 2” lower than side bond beam D Standard inside housing for pools up to 55’ long 14” Wide 14” Deep (from side bond beam elevation) Bond Wire Motor Location 2 ½ “ Chase to equipment pad to run hydraulic hoses 3” Drain Non-Motor End X Note: To determine motor side for ordering, stand at the “x” looking the direction of the arrow. Which side is the motor on? (Left hand motor shown) Coverstar East Coast, Inc. Concrete Cover Box Detail - Top View TO AIR EXCAVATION 12” DRAIN 12” TO AIR This CONCRETE wall must be straight and plumb, 12” thick J-BOX 3 3 DRAIN 14” TYPICAL 2 36” 12” 1 2 ELECTRIC 6 12” NOTES: 1. THIS BOX EXAMPLE SHOWS A MOTOR-LEFT, BUT THE MOTOR CAN BE ON EITHER SIDE. 2. THE MOTOR-END OFFSET IS 36” (MINIMUM) FROM THE INSIDE EDGE OF POOL WALL. THE NON-MOTOR SIDE OFFSET IS 12” (MIN) FROM THE INSIDE EDGE OF THE POOL WALL. 3. DRAIN(S) MUST BE 3” (MIN), AND MUST DRAIN TO OPEN AIR. 4. BOX WALLS ARE TO BE 12” THICK TO SUPPORT STONE LID BRACKETS. 5. INSIDE BOX DIMENSIONS ARE 14” WIDE BY 14” DEEP FOR POOLS UP TO 55 FEET IN LENGTH. BOXES FOR POOLS OVER 55 FEET REQUIRE MORE SPACE. MAKE INSIDE DIMENSIONS 16” WIDE BY 16” DEEP. BOX LENGTH REMAINS AS INDICATED ABOVE. 6. 1/2” ELECTRICAL CONDUIT ENTRY SHOULD BE SET 3” BELOW THE TOP OF THE COVER BOX ON THE MOTOR SIDE, WITH A JUNCTION BOX ANCHORED TO THE WALL. NOT TO SCALE Coverstar East Coast, Inc. Drawing #210 - Rev. 01/31/11 SIDE BOND BEAM SIDE BOND BEAM LOWERED BOND BEAM - 2” CLEARENCE FROM BOTTOM OF COPING COPING OVERHANG = 21/2” (THE FLAT SURFACE ONLY) 2 .5” 2” BOND BEAM CLEARENCE = 2” min. Coverstar East Coast, Inc. Coping Overhang Detail DECKING BULLNOSE EXPANSION JOINT MORTAR BED COPING STONE 2-1/2” MIN. SOIL WATER SIDE BOND BEAM TILE PLASTER NOT TO SCALE Coverstar East Coast, Inc. Drawing # - Rev. 01/31/11 Page Coverstar East Coast, Inc. EXPANSION JOINT DECK MORTAR BED MAXIMUM OVERHANG ¾” COPING STONE ½” MORTAR ON TOP OF ENCAPS ENAPSULATED GUIDE GUIDE LOCKING STRIP MORTAR BED FOR LEVELING THE ENCAPSULATED GUIDE 3” WIDE BEHIND THE TILE BACKFILL WATER ENCAPSULATION INSTALLATION STEPS FOR GUNITE POOLS SIDE BOND WALL 1. AFTER POOL IS SHOT INSTALL TILE TO LEVEL THE WALLS. 2. CREATE A MORTAR BED 3” WIDE LEVEL WITH THE TOP OF THE TILE FOR THE ENCAPSULTION TO REST ON. 3. INSTALL ENCAPSULATED GUIDE. 4. SET COPING IN ½” OF MORTAR ON TOP OF THE ENCAPSULATION WITH NO MORE THAN ¾” OF OVERHANG. TILE PLASTER NOT TO SCALE Coping Overhang Detail – Gunite Encapsulated Guide Coverstar East Coast, Inc. Drawing #000 - Rev. 01/31/11 Coverstar East Coast, Inc. Concrete Cover Box Detail – Alum Lid w/Pavers NOTE: the first three pavers behind box must be set in mortar over concrete LEVEL SURFACES COVER GUIDE MORTAR ALUMINUM LID COPING PAVERS LID BRACKET TILE WATER 14” CONCRETE 14” LOWERED BOND BEAM SOIL PLASTER MINIMUM 3” DRAIN NOT TO SCALE Coverstar East Coast, Inc. Drawing #203 - Rev. 01/31/11 Coverstar East Coast, Inc. Coverstar Concrete Box Detail Stone Lid with Poured Deck LEVEL SURFACES COVER GUIDE COPING DECK MUST BE PLUMB WITH INSIDE SURFACE OF BOX POURED DECK - TYPICALLY 3-1/2” LID STONE 24 x 14 TYPICAL TILE LID BRACKET 12” WATER 2” LOWERED BOND BEAM (1/2” SLOPE) 14” ANCHOR BOLTS 14” TOP OF CONCRETE LEVEL WITH TOP OF SIDE BOND BEAM BACKFILL CONCRETE MUST BE A MINIMUM OF 12” AT BACK OF BOX PLASTER GUNITE / SHOTCRETE END VIEW NOT TO SCALE MINIMUM 3” DRAIN REQUIRED NO DRAIN, NO WARRANTY Page BOX SIZE CHART Pool Length Pool Width 0’ to 26’ 0’ to 55’ 0’ to 26’ 55’’ to 75’ 26’to 32’ 0’ to 55’ 26’ to 32’ 55’ to 75’ Coverstar East Coast, Inc. Box Size 14” by 14” 16” by 16” 16” by 16” 18” by 18” Roll-Up Tube 6” standard 6” heavy duty 8” standard 8” heavy duty Drawing #211 - Rev. 1/31/11 Coping Stone or Poured Concrete Stone Lid THE DECK AREA SURROUNDING THE LID MUST BE FLAT AND LEVEL END TO END NO BREAK IN THIS AREA (STONES SHOULD SPAN OVER TRACK) DECK AREA LID STONES Non-Motor End Motor End TILED DAM WALL SPECIFICATIONS: THE DECK AREA SURROUNDING THE LID MUST BE FLAT AND COMPLETELY LEVEL END TO END. DECK AREA COPING STONES OR POURED STONES SHOULD BE 14” WIDE, 24” LONG, AND 2” THICK (MINIMUM). THEY MUST FILL THE ENCLOSURE AREA FROM END TO END, WITH APPROXIMATELY 1/8” GAP BETWEEN STONES. STONES SHOULD BE APPROX. 1/4” NARROWER THAN THE ENCLOSURE WIDTH AT MOTOR END, AND NONMOTOR END (WHERE SURROUNDED BY DECK BOTH FRONT AND BACK). STONES MAY BE WIDER IN THE OPEN AREA BETWEEN POOL WALLS. WHEN POSSIBLE POURED STONES SHOULD BE 1/2” THINNER THAN POOL DECKING (NEVER THICKER) TO LEAVE ROOM FOR THE LID BRACKETS. POURED STONES MUST BE FLAT AND SMOOTH, TOP AND BOTTOM. (AN UP-CHARGE WILL APPLY IF STONES ARE TOO HEAVY FOR ONE PERSON TO MANAGE). STONES MUST BE CUT OR POURED TO SIZE AND LAID OUT IN ORDER BEHIND THE COVER ENCLOSURE BY THE DAY OF INSTALLATION IF COVERSTAR IS TO SET THEM. STONES SHOULD BE DOUBLE-CHECKED FOR FIT PRIOR TO INSTALLATION. COVERSTAR WILL INSTALL THE BTACKETS, SET THE STONES, AND LEVEL THE LID, BUT CAN NOT ALTER THE STONES TO FIT. LID BRACKETS ARE SET ON 24” CENTERS AND LID STONES ARE SET TO SPAN OR BRIDGE THE DISTANCE. COVERSTAR IS NOT RESPONSIBLE FOR THE STRENGTH OF INDIVIDUAL LID STONES. ADDITIONAL LID BRACKETS CAN BE PROVIDED AT EXTRA COST TO SUPPORT SOFT STONES. TOP VIEW NOT TO SCALE Walk-On Lid Detail Coverstar East Coast, Inc. Drawing #6101701 - Rev. 1/31/11 DECK EDGE COPING STONES DECK AREA Coping Stone or Poured Concrete Stone Lid THE DECK AREA SURROUNDING THE LID MUST BE FLAT AND LEVEL END TO END NO BREAK IN THIS AREA (STONES SHOULD SPAN OVER TRACK) DECK AREA LID STONES Non-Motor End Motor End TILED DAM WALL SPECIFICATIONS: THE DECK AREA SURROUNDING THE LID MUST BE FLAT AND COMPLETELY LEVEL END TO END. DECK AREA COPING STONES OR POURED STONES SHOULD BE 14” WIDE, 24” LONG, AND 2” THICK (MINIMUM). THEY MUST FILL THE ENCLOSURE AREA FROM END TO END, WITH APPROXIMATELY 1/8” GAP BETWEEN STONES. STONES SHOULD BE APPROX. 1/4” NARROWER THAN THE ENCLOSURE WIDTH AT MOTOR END, AND NON-MOTOR END (WHERE SURROUNDED BY DECK BOTH FRONT AND BACK). STONES MAY BE WIDER IN THE OPEN AREA BETWEEN POOL WALLS. WHEN POSSIBLE POURED STONES SHOULD BE 1/2” THINNER THAN POOL DECKING (NEVER THICKER) TO LEAVE ROOM FOR THE LID BRACKETS. POURED STONES MUST BE FLAT AND SMOOTH, TOP AND BOTTOM. (AN UP-CHARGE WILL APPLY IF STONES ARE TOO HEAVY FOR ONE PERSON TO MANAGE). STONES MUST BE CUT OR POURED TO SIZE AND LAID OUT IN ORDER BEHIND THE COVER ENCLOSURE BY THE DAY OF INSTALLATION IF COVERSTAR IS TO SET THEM. STONES SHOULD BE DOUBLE-CHECKED FOR FIT PRIOR TO INSTALLATION. COVERSTAR WILL INSTALL THE BTACKETS, SET THE STONES, AND LEVEL THE LID, BUT CAN NOT ALTER THE STONES TO FIT. LID BRACKETS ARE SET ON 24” CENTERS AND LID STONES ARE SET TO SPAN OR BRIDGE THE DISTANCE. COVERSTAR IS NOT RESPONSIBLE FOR THE STRENGTH OF INDIVIDUAL LID STONES. ADDITIONAL LID BRACKETS CAN BE PROVIDED AT EXTRA COST TO SUPPORT SOFT STONES. TOP VIEW NOT TO SCALE Mirrored Walk-On Lid Detail Coverstar East Coast, Inc. Drawing #6101702 - Rev. 00 DECK EDGE COPING STONES DECK AREA Coping Stone or Poured Concrete Stone Lid THE DECK AREA SURROUNDING THE LID MUST BE FLAT AND LEVEL END TO END NO BREAK IN THIS AREA (STONES SHOULD SPAN OVER TRACK) DECK AREA LID STONES Non-Motor End Motor End TILED DAM WALL SPECIFICATIONS: THE DECK AREA SURROUNDING THE LID MUST BE FLAT AND COMPLETELY LEVEL END TO END. DECK AREA COPING STONES OR POURED STONES SHOULD BE 14” WIDE, 24” LONG, AND 2” THICK (MINIMUM). THEY MUST FILL THE ENCLOSURE AREA FROM END TO END, WITH APPROXIMATELY 1/8” GAP BETWEEN STONES. STONES SHOULD BE APPROX. 1/4” NARROWER THAN THE ENCLOSURE WIDTH AT MOTOR END, AND NON-MOTOR END (WHERE SURROUNDED BY DECK BOTH FRONT AND BACK). STONES MAY BE WIDER IN THE OPEN AREA BETWEEN POOL WALLS. WHEN POSSIBLE POURED STONES SHOULD BE 1/2” THINNER THAN POOL DECKING (NEVER THICKER) TO LEAVE ROOM FOR THE LID BRACKETS. POURED STONES MUST BE FLAT AND SMOOTH, TOP AND BOTTOM. (AN UP-CHARGE WILL APPLY IF STONES ARE TOO HEAVY FOR ONE PERSON TO MANAGE). STONES MUST BE CUT OR POURED TO SIZE AND LAID OUT IN ORDER BEHIND THE COVER ENCLOSURE BY THE DAY OF INSTALLATION IF COVERSTAR IS TO SET THEM. STONES SHOULD BE DOUBLE-CHECKED FOR FIT PRIOR TO INSTALLATION. COVERSTAR WILL INSTALL THE BTACKETS, SET THE STONES, AND LEVEL THE LID, BUT CAN NOT ALTER THE STONES TO FIT. LID BRACKETS ARE SET ON 24” CENTERS AND LID STONES ARE SET TO SPAN OR BRIDGE THE DISTANCE. COVERSTAR IS NOT RESPONSIBLE FOR THE STRENGTH OF INDIVIDUAL LID STONES. ADDITIONAL LID BRACKETS CAN BE PROVIDED AT EXTRA COST TO SUPPORT SOFT STONES. TOP VIEW NOT TO SCALE Mirrored Walk-On Lid Detail Coverstar East Coast, Inc. Drawing #6101702 - Rev. 00 DECK EDGE COPING STONES DECK AREA Coverstar East Coast, Inc. STONE LID INSTALLATION POLICY 1. Coverstar East Coast requires stones to be on site and adjacent to the box at the time of installation. There will be an additional charge at our hourly rate if the stones are not adjacent to the pool at the time of installation. 2. In the event that that stones are not present, we need the following information. We, ________________, request the following action if the lid stones are not on site. Pool Builder Do NOT install the lid brackets. NOTE: We will assume responsibility for the installation of the brackets or we understand that an additional trip charge will apply to have Coverstar come to install brackets. Install stone lid brackets level with the underside of coping every ______ inches. Notify us every time this situation occurs so we can offer further instruction to Coverstar installer. P:\Technical Information & Drawings\Builder Spec Books\2011 Builder Book Rebuild\Originals\Gunitep10-STONE LID INSTALLATION POLICY CUSTOM SIZE 4.000 .875 11.000 .500 1.000 COVERSTAR BOX SIZE CHART Pool Length Pool Width 0’ to 26’ 0’ to 55’ 0’ to 26’ 55’ to 75’ 26’ to 32’ 0 to 55’ 26’ to 32’ 55’ to 75’ Box Size 14” by 14” 16” by 16” 16” by 16” 18” by 18” NOTE: the first three rows of pavers/brick behind box must be set in mortar over concrete SCREW-ON UNDERGUIDE ½” MORTAR BASE PAVERS/BRICK IN MORTAR TRAY TILE PAVERS/BRICK 2” LID BRACKET WATER WEDGE ANCHOR 14” BACKFILL LOWERED BOND BEAM 14” CONCRETE PLASTER PAVERS/BRICK IN MORTAR TRAY BULLNOSE PAVER/BRICK DETAIL MINIMUM 3” DRAIN END VIEW NOT TO SCALE Concrete Box Detail – BRICK TRAY LID with PAVERS/BRICK, SCREW-ON UNDERGUIDE Coverstar East Coast, Inc. Drawing #05060200 - Rev. 02-01-11 Roll Up Tube 6” standard 6” heavy duty 8” standard 8” heavy duty Coverstar East Coast, Inc. BOX SIZE CHART Pool Length Pool Width 0’ to 26’ 0’ to 55’ 0’ to 26’ 55’ to 75’ 26’ to 32’ 0’ to 55’ 26’ to 32’ 55’ to 75’ Box Size 14” by 14” 16” by 16” 16” by 16” 18” by 18” Roll Up Tube 6” standard 6” heavy duty 8” standard 8” heavy duty LE Bar 3” 3” 4” 4” Skimmer Baskets Set 3” Lower Set 3” Lower Set 5” Lower Set 5” Lower A REINFORCED GALVANIZED STEEL LID BRACKET 26” PRECAST LID STONES COPING SCREW-ON UNDERGUIDE 6” or 8” 8” POURED DECK BACKFILL 16” WATER 14” SECTION A TILE BOND BEAM (12” THICK) COPING LEADING EDGE BAR 14” PLASTER SLIDER UNDER GUIDE OR TRACK POOL WALL MINIMUM 3” DRAIN END VIEW NOT TO SCALE Concrete Box Detail - Hidden Leading Edge Coverstar East Coast, Inc. Drawing #000 - Rev. 2/01/11 CONCRETE MUST BE A MINIMUM OF 8” AT BACK OF BOX TO SUPPORT EXTENDED LID BRACKETS COVERSTAR EAST COAST, INC. 1704 Back Acre Circle Mt. Airy MD 21771 800-870-3329 Fax 301-829-6686 STONE LID LAYOUT FOR HIDDEN LEADING EDGE Bond Beam Coping Notched & Lowered Bond Beam 24” 26” Note: Coping Stone Stops here Not here (on both sides) 14” 1st Lid Stone (14” x 24”) 2nd Lid Stone (26” x 24”) Cover Housing Note: 2nd Lid Stone and Last Lid Stone do not line up with inside (pool) edge of coping stone Last Lid Stone RAISED WALL DETAIL FOR COVER HOUSING B D A C A.) TRACK LOCATION MUST HAVE MINIMUM 2” CANTILEVER AND 1” CLEARANCE FROM TOP OF END BONDBEAM TO BOTTOM OF CANTILEVER B.) CAVITY DEPTH RECESSED INTO WALL SHOULD BE A MIN. OF 9” FROM POOL WATER WALL C.) D.) HOUSING WIDTH 14” STANDARD FOR COVERS 55’ OR LESS. UNDER SIDE OR “CEILING” OF COVER HOUSING MUST BE SAME ELEVATION AS FINISHED DECK HEIGHT. P:\Technical Information & Drawings\Builder Spec Books\2011 Builder Book Rebuild\Originals\Gunite-Specialized P:\Technical Information & Drawings\Builder Spec Books\2011 Builder Book Rebuild\Originals\Gunite‐Specialized VANISHING EDGE TOPGUIDE P:\Technical Information & Drawings\Builder Spec Books\2011 Builder Book Rebuild\Originals\Gunite-Specialized P:\Technical Information & Drawings\Builder Spec Books\2011 Builder Book Rebuild\Originals\Gunite-Specialized P:\Technical Information & Drawings\Builder Spec Books\2011 Builder Book Rebuild\Originals\Gunite-Specialized P:\Technical Information & Drawings\Builder Spec Books\2011 Builder Book Rebuild\Originals\Gunite-Specialized VANISHING EDGE ON MECHANISM END P:\Technical Information & Drawings\Builder Spec Books\2011 Builder Book Rebuild\Originals\Gunite-Specialized EXTREME CANTILEVER P:\Technical Information & Drawings\Builder Spec Books\2011 Builder Book Rebuild\Originals\Gunite-Specialized FORMING EXTREME CANTILEVER P:\Technical Information & Drawings\Builder Spec Books\2011 Builder Book Rebuild\Originals\Gunite-Specialized 14” 14” 14” 14” P:\Technical Information & Drawings\Builder Spec Books\2011 Builder Book Rebuild\Originals\Gunite-Specialized 14” 14” P:\Technical Information & Drawings\Builder Spec Books\2011 Builder Book Rebuild\Originals\Gunite-Specialized 3 WIRE MOTOR WITH CIRCUIT & FEATURE BOARD SINGLE GANG BOX CIRCUIT BOARD WIRING KEYSWITCH BLUE BLUE FEATURE WIRING POWER SUPPLY CONTACTOR COIL HOT MOTOR NEUTRAL HOT NEUTRAL WHITE BLACK The wires indicated as feature relay are intended to interrupt the power supply to a contactor used to operate the feature. GREEN WHITE YELLOW BLACK B D F ACE BLACK WHITE LIMITS RED BLUE FEATURE RELAY BLACK WHITE GREEN ALL-WEATHER BOX 1 - POWER IN (HOT) - BLACK 2 - POWER IN (NEUTRAL) - WHITE 3 - MOTOR NEUTRAL - YELLOW 4 - MOTOR DIRECTIONAL - BLUE 5 - MOTOR DIRECTIONAL - RED A - KEYSWITCH DIRECTIONAL - BLUE B - KEYSWITCH DIRECTIONAL - RED C- KEYSWITCH COMMON - BLACK D - LIMITS COMMON - BLACK E - LIMIT - WHITE F - LIMIT - YELLOW RED BLACK PANEL 110v. RED BLACK YELLOW BLACK BLUE WHITE GREEN RED WHITE BLACK NOTES: 1. Motor is rated at 10 Amps , use appropriate wire size throughout the system. 2. Use 15 amp GFCI breaker at panel. 3. Follow all applicable codes. 4. Change motor direction by switching directional wires at the kEy switch. 5. Two all-weather boxes and conduits are required in the mechanism pit so that the high and low voltage wires are not run together in the same conduit. 6. Water feature rating = 20 amps Normally open, 10 amps Normally closed CAPACITOR CAPACITOR DESIGNATES WIRE NUT 1 BLUE YELLOW 5 4 3 2 RED GREEN MOTOR 9-23-2004 Coverstar East Coast, Inc. MOTORIZED COVER WINTER USE POLICY The question is often asked, “Do you recommend using the motorized cover (ECLIPSE) as a winter cover?” The answer is that it is a matter of personal choice. We neither recommend nor discourage use of the motorized cover as a winter cover. We are neutral on this issue. In order to help you make a decision, we have listed below some of the items you should consider when making your choice. 1. When proper precautions are taken, motorized covers are successfully used as a winter cover. 2. During the winter the proper water level must be maintained as the water supports the ice and snowmelt buildup. The best method is to blow out the lines and use filter plugs & cover plates so that the water level does not have to be lowered. In no case should the water level be lowered more than 6 inches below the track. 3. The cover pump must be left on the cover and plugged in, so that as water accumulates from the ice and snow melting, it will be pumped off of the cover. Excessive amounts should not be allowed to build up on top of the cover. Attempting to break and remove snow, or ice from the cover can cause damage to both the cover itself and the tracks. The cover should never be operated if it has water, snow or ice on it. 4. There are some risks associated with using the motorized cover as a winter cover, such as the water level dropping below the recommended level. If the pool loses water because of a leak or for any other reason, there may not be enough support for the cover. This could cause the tracks to pull down, possibly damaging the material to which it is attached as well as the cover itself. However, if there is adequate slack in the cover and the water level is properly maintained, there is little likelihood of problems occurring. 5. The cover is not warranted against damage to the cover or pool due to winter use, just as the warranty does not cover damage due to such things as mudslides, earthquakes, falling trees, etc. 6. Leaves and debris should be removed from the cover as they accumulate to avoid damage and staining the cover. 7. A cover should only be used as a winter cover if it has the proper slack. Proper slack is determined by where the cover touches the water. When the water level is lowered, the cover should normally touch the water no more that 12 inches from the edge of the pool. Actual slack requirements may vary depending on local conditions. 8. Another consideration has to do with the longevity of the cover. The cover will not last as long when used as a winter cover because of added exposure to the elements. If it is not used as the winter cover, it should be cleaned and rolled up during the wintertime. 01-31-2011 Coverstar East Coast, Inc. 1704 Back Acre Circle • Mount Airy, MD 21771 Toll Free: (800) 870-3329 • Fax: (301) 829-6866 www.coverstareastcoast.com P:\Technical Information & Drawings\Builder Spec Books\2011 Builder Book Rebuild\Originals\Gunite Coverstar East Coast, Inc. SLACK IN AUTOMATIC POOL COVERS From time to time the question arises about the need for slack in automatic pool covers and how much is enough. Regardless of manufacturer, all automatic pool cover fabrics are made wider than the width of the track. There are several reasons for this: 1. A cover that is too tight will pull against the tracks and will not operate properly. A cover that is made too small reduces the life of the cover and mechanism, causing premature failure of both the fabric and the mechanism due to the added stress. 2. All fabric shrinks over a period of time. The amount of the shrinkage varies widely according to the type of fabric, how the fabric is manufactured, the temperature of the water, and the weather conditions. Slack is added to the fabric to compensate for fabric shrinkage. 3. The cover must lie on the water in order to meet he ASTM safety standards. Most of the supporting strength of the cover comes from the support of the water directly under it. Each cover we manufacture is made with the sack calculated on the basis of the type of fabric, application and unit. Any other variables that may be brought to our attention are also included. Initially, a properly sized cover will drop almost directly down from the track or deck to the water, with some folds & wrinkles as it crosses the pool. Because each cover is subject to many variables, it is impossible to calculate the exact amount of shrinkage each individual cover will have, so an approximation is made based on our past experience. Our slack formula is designed to give the cover and mechanism maximum life, as well as making the cover look as attractive as possible. Before an order for any cover which has less that the factory specified slack is processed, we must receive a signed statement from the customer which releases Coverstar from any warranty or safety liability issues which may arise because of premature failure of the fabric or system due to fabric shrinkage. In some cases, a portion of the slack may be taken up by lowering the water level. However, you should consult with your pool builder or service man before doing so. They can advise you exactly where the water level should be to keep the pool equipment operating properly. The slack in the front of the cover must be spread over the length of the leading edge, keeping it away from the sides near the tracks. If this is not done, it is possible that the fabric may fold over and get caught in the track. The leading edge loop size has been designed to give maximum flexibility in properly installing and servicing the cover. P:\Technical Information & Drawings\Builder Spec Books\2011 Builder Book Rebuild\Originals\Gunite Coverstar East Coast, Inc. WARRANTY SUMMARY ITEM 1. Mechanism – All mechanical parts of reel mechanism except: rope pulleys, guide feeds and slides (considered consumed through use) * WARRANTY PERIOD CS3000: 10 Years ECLIPSE 20 Years WARRANTEED BY Coverstar, LLC. 2. Extrusions – guides (tracks), leading edge bar, lid and hinge and take-up tube * 3 Years Coverstar, LLC. 3. Electrical components – motor switch 5 years 3 years Coverstar, LLC. Coverstar, LLC. 7 years – The first 36 months is 100% repair or replacement, after 36 months it is pro-rated from the 1st month to the 84nd month. Coverstar LLC. 5. Ropes 2 years Coverstar LLC. 6. Cover Pump, Rule 3 Years ITT Rule 1 Year Coverstar East Coast, Inc. 4. Fabric (cover material) – (Ropes and webbings are covered only if it is determined that they had a manufacturing defect.) * *Customers must call ITT Rule directly @ 978-282-5232 and ask for Sandy Sanagra Customer Service: 978-281-0573 7. Labor (if installed by Coverstar East Coast) *Note: See actual warranty for complete details P:\Technical Information & Drawings\Builder Spec Books\2011 Builder Book Rebuild\Originals\Gunite\p13-Warranty Summary.doc MEMO Date: January 8, 2001 To: To Whom it May Concern From: Harold Rogers, V.P. Sales Re: Coverstar safety covers: UL and ASTM standard F 1346-91 for safety covers for swimming pools All Coverstar covers fully certified by UL and meet the ASTM standard for safety covers as specified in ASTM standard F 1346-91 when they are installed and maintained properly according to the installation and homeowner instructions which have been provided by Coverstar. On several different occasions, the Coverstar covers, both automatic and manual have been tested by independent testing laboratories and have always been found to be in compliance with all the ASTM requirements for safety covers. Our cover is also listed by UL (File E164833) and classified by UL as a power safety cover in accordance with ASTM F 1346-91 If you wish to verify either of the UL certifications, take the following steps: Go to www.ul.com Once there click on Search UL.com Click on Online Certifications Directory. Under General Search click on UL File Number Type in E164833 and hit enter You should now see Coverstar’ s listings. If you have problems, you can also search by company or by Automatic Pool Covers If more information is required about ASTM and its standards, you can go to their website at www.astm.org. Shown below is the UL authorized label that is attached to the automatic cover system that we ship. If you have any further questions about our covers, the UL certifications or the ASTM standards, please call or Email me. L0127 3-08-04 COVERSTAR INC. 1795 West, 200 North, Lindon, UT 84042 Phone 800-617-7283 Fax 801-373-5095 Email [email protected] Coverstar East Coast, Inc Motorized Cover Installation Readiness Checklist Builder Name: ________________________________ Supervisor’s Name/Number:_________________________________ Homeowner Name: _______________________________ Is there water in the pool? If NO, when will the pool be filled: _______________________ Is the deck done? Is there a raised bond wall? If YES, is the track installed? Is the motor side the same as what was ordered? YES NO YES YES YES YES NO NO NO NO YES YES YES NO NO NO YES YES NO NO YES NO YES YES NO NO Electric How many switches will be installed? Has (have) the switch location(s) been determined & conduit run to it (them)? Has (have) the box(s) for the switch(s) been installed? Has the junction box for the motor connection been installed in the box end wall of the box 3” from the top? Are there three 12 gauge wires from the power panel to the switch box? Are there four 12 gauge wires between the switch box and the motor box? Is the 15 AMP GFCI breaker installed? ONE YES YES YES YES YES YES TWO NO NO NO NO NO NO Hydraulic Has the sleeve been run yet? Is there a location for the power pack? Has it been wired for 220 volts? YES YES YES NO NO NO Deck Has the deck been finished behind the cover housing where the lid will mount? YES NO Stone Lid Are lid stones on site and next to cover housing? YES NO YES NO Cover Box Is there a working drain in the cover box? Does concrete surround (min 6”) around the box, all the way to the bottom? Is the electric conduit in place at the motor-end of the box? Is the cover box 14’’ wide & 14” deep (from underside of coping) with 36” offset from waters edge on motor side and 12” offset on non-motor side? Is the back wall of the cover box vertical, smooth and without joints where the lid brackets mount? Encapsulation Is there encapsulation installed on this job? (If yes, skip coping section) Coping Is the coping at least 2” thick? Is there at least 2 ½” of flat surface on the underside of the coping to mount track? System Type What type of system is being installed: HYDRAULIC ELECTRIC If ELECTRIC, continue answering the following set of questions. If HYDRAULIC, skip to indicated section. Will the homeowner be present for installation? If NO, who is to instruct the homeowner on the operation and care of the cover and pump? P:\Technical Information & Drawings\Builder Spec Books\2011 Builder Book Rebuild\Originals\Gunite