Cut Sheet - Myers Power Products
Transcription
Cut Sheet - Myers Power Products
SEISMIC CATALOG ALSO AVAILABLE FROM MYERS POWER PRODUCTS: ILLUMINATOR E-H/IE-H & ILLUMINATOR CIII-H Illuminator Series E/IE Single Phase 1.5kVA/kW to 16.7kVA/kW Illuminator Series CIII Three Phase 4.8kVA/kW to 50kVA/kW UL-924 Listed Emergency Lighting and Power Equipment 1.5kVA/kW to 16.7kVA/kW Single Phase 4.8kVA/kW to 50kVA/kW Three Phase 65kAIC Rated Shaker Table Tested to SDS Level 2.5 Illuminator Series EM Single Phase 1kVA/kW to 2.8kVA/kW Listed to CBC2010, IBC2009, AC156 44 S. Commerce Way Bethlehem, PA 18017 Phone: (610) 868-3500 Fax: (610) 868-8686 www.myerspowerproducts.com Illuminator Series CR/DR Single and Three Phase Outdoor System 3kVA/kW to 8kVA/kW ELP-0008-DS-1212 98% Efficient SYSTEM SPECIFICATIONS THE ILLUMINATOR -H SEISMIC SERIES The Illuminator Series E/IE-H and CIII-H are the latest innovation in Emergency Lighting Inverter technology. The Illuminator -H series is Myers’ shaker table tested and approved expansion to the industry leading Central Emergency Lighting inverters. INPUT Voltage Input Power Walk-in Input Frequency Synchronizing Slew Rate Protection AIC Rating Power Factor These systems meet the requirements of CBC 2010 and IBC 2009 and have been shaker table tested in accordance with ICC-ES-AC-156 procedures to an SDS level of 2.5g. In addition they have received OSHPD (California Office of Statewide Health Planning and Development) Special Seismic Certification. This is the most rigid seismic standards currently being specified. SEISMIC SYSTEMS E-H, IE-H, CIII-H OUTPUT Voltage Dynamic Voltage Harmonic Distortion Overload Output Frequency Load Power Factor Inverter Overload Illuminator E-H The Illuminator Series E-H single phase uninterruptible system features sizes from 1.5-16.7 kVA/kW. This fast transfer system is designed to support all types of fixtures in emergency applications including HID, LED, and fluorescent. In addition this system can support mixed loads of all different types. The line interactive design eliminates excessive transfers to battery power. The Illuminator Series E-H transfers to inverter mode (battery power) within 2ms of loss of utility power in order to maintain the arc of an HID light. Protection Crest Factor Illuminator CIII-H Type Charger Protection Disconnect Optional Runtimes Altitude Operating Temperature Storage Temperature Relative Humidity • 1 < 10,000 feet (above sea level) without derating. Inverter: 0° to 40°C (32° to 104°F); Battery: 20° to 30°C (68° to 86°F) per UL 924. -20° to 70°C (-4° to 158°F) (electronics only). < 95% (non-condensing). GENERAL Efficiency Design Output Circuits Generator Input Control Panel STANDARD FEATURES Illuminator E/IE-H UL 924 Listed 98% Efficient PWM/IGBT Technology Micro-processor Control User Programmable Front Meter Panel Automatic Selt-test, Event and Alarm Logs OSHPD Special Seismic Certification No. OSP-0305-10 High Crest Factor Valve-regulated, sealed lead-calcium. Microprocessor controlled and temperature compensating; recharge per UL 924 spec. Automatic low-battery disconnect; automatic restart upon utility return. Series E-H / IE-H and Series CIII-H, 4.8-16.7k fuse(s); Series CIII-H, 24-50k circuit breaker / fuse(s). Extended run times available. Consult factory for additional information. ENVIRONMENTAL The Illuminator Series CIII-H three phase uninterruptible system features sizes from 4.8 to 50 kVA/kW. As with Myers’ other uninterruptible systems the CIII-H series is designed to support all lamp sources including HID and LED. Its large capacity is perfect for larger industrial and commercial applications. It can also help to provide load balancing within a facility with its wide range of sizes. • • • • • • • 120 or 277VAC, 1-phase, 2-wire + G (Series E-H / IE-H). 120/208 or 277/480VAC, 3-phase, 4-wire + G (Wye or Delta) (Series CIII-H). Contact factory for all other voltages. +/- 2% for +/-25% load step change, recovery within 3 cycles. < 3% THD for linear load. Fuse protected. 60Hz +/- 0.05Hz during emergency mode. 0.5 lag to 0.5 lead. 115% for 10 minutes; 125% for 5 minutes; 280% for 16 line cycles (Series E-H / IE-H); 280% for 12 line cycles (Series CIII-H). Series E-H / IE-H - main or distribution circuit breaker(s). Series CIII-H - optional main circuit breaker. 2.8 BATTERY Illuminator IE-H The Illuminator Series IE-H single phase standard transfer system features sizes from 1.5-16.7 kVA/kW; it is designed to support all lighting loads except HID. This includes LED, fluorescent, incandescent and quartz fixtures. This system comes standard with normally on and normally off (emergency only) outputs. 120 or 277VAC (+10% / -20%), 1-phase, 2-wire + G (Series E-H). 120 or 277VAC (+10% / -15%), 1-phase, 2-wire + G (Series IE-H). 120/208 or 277/480VAC (+10% / -15%), 3-phase, 4-wire + G (Wye) (Series CIII-H). Contact factory for all other voltages. Limiting inrush current to less than 125% of full rated load; 10 times for 1 line cycle. 60Hz, +/- 3%. 1Hz per second nominal. Input Circuit Breaker. 65k RMS symmetrical ampere short-circuit rating. 0.5 lag/lead. • • • • • • • • Input Main Circuit Breaker True Output Sine Wave Meets NFPA-101 for self-testing and selfdiagnostics Low Audible Noise 45Dba Modular Design Load Reduction Fault Air Filters not required 65 kAIC rating Metering Alarms Communications Manual Maintenance Bypass Alarm Contacts Warranty Factory Start-up 5-Year Maintenance Plan 98%. Standby UPS; PWM inverter type utilizing IGBT technology with 2ms transfer time on Series CIII-H and Series E-H and 50ms on Series IE-H. Series E-H - Normally On Circuit standard; Normally Off Circuit optional. Series IE-H - Normally On and Normally Off Circuits standard. Series CIII-H - Normally On Circuit standard; Normally Off Circuit optional. Compatible with generators. Microprocessor controlled with user friendly display, touchpad controls/functions and system status indications. Input & Output Voltage, Battery Voltage, Battery & Output Current, Output VA, Temperature, Inverter Wattage. High/Low Battery Charger Fault, Near Low Battery, Low Battery, Load Reduction Fault, Output Overload, High/Low AC Input Volts, High Ambient Temperature, Inverter Fault, Output Fault, Test Failure, and Optional Circuit Breaker Trip. RS-232 port (DB9 standard). See ordering guide for additional available options. Standard internal on Series CIII-H; optional internal on Series E-H / IE-H. Make before break. Optional summary alarm and / or status monitoring form "C" contacts. 1 year standard warranty includes all parts, labor & travel expenses within the 48 contiguous states. 10 years prorated warranty on batteries. Extended warranties, preventative maintenance and customized service plans are available. Purchase factory start-up & receive 1 additional year of electronics warranty. Purchase 5-year preventative maintenance plan & receive free factory start-up. PHYSICAL Cabinet Cooling Cable Entry Access Freestanding NEMA Type 1; reinforced and approved for seismic withstand. Forced air during emergency. Convection cooled during normal operation. No filters required. Series E-H / IE-H: top or sides on 1.5 - 5kVA; sides only on 6 - 16.7kVA. Series CIII-H: top, bottom or sides. Front ONLY is required. 6 ILLUMINATOR E/IE-H SINGLE PHASE ORDERING GUIDE Example Model Number 1-DH-4-S-C3001-C-I-S-2YW SYSTEM TYPE BATTERY TYPE OUTPUT BREAKERS DH - Illuminator Series “CIII-H” S-Standard (VRLA) Example: C XX 01 VOLTAGE (INPUT/OUTPUT)1 KVA/KW2 RUNTIME3 1 - 120/208 2 - 277/480 1 - 4.8 2-6 3-8 4 - 10 5 - 12.5 6 - 16.7 7 - 24 8 - 33 9 - 40 10 - 50 (90 minutes) 2YW- Factory Start-Up Extended 2-Year Electronic Warranty 5YW- 5-Year Electronics Warranty (Includes Start-up) 5YP- 5-Year Maintenance Plan, Start-Up Included POLE (See chart on page 3 for dimensional details) C - 3-Pole OPTIONS AMP RATING A - Remote Summary Alarm Panel C - Status Monitoring Dry Form C Contacts F - Fast Charge I - Inverter On Dry Form C Contact S - Summary Dry Form C Contact (Based on System KVA SIZE) 1) Standard input voltage is 4-Wire Wye. 3-Wire Delta Input requires external isolation transformer. 2) KVA = KW 3) Standard battery run time is 90 minutes. 4) Standard 1 year full warranty UPS ELECRONICS MODULE WARRANTY4 01 BATTERIES BATTERY MODULE TOTAL SYSTEM DIMENSIONS Power Rating (kW) Efficiency (@ full load) Voltage (VDC) Audible Noise (dBA @ 1m) Base Model Number DH-1-S DH-2-S DH-3-S 5 Weight lbs/kg Total Battery Weight lbs/kg Run Time (mins) Number of Battery Cabinets Weight lbs/kg 4.8 6.0 8.0 98 45 326 98 45 408 98 45 544 535/243 535/243 535/243 888/403 1110/504 1480/672 12 15 20 DH-4-S 10.0 10.0 DH-5-S 12.5 12.5 DH-6-S 16.7 16.7 98 45 680 98 45 850 98 45 1136 639/290 639/290 639/290 1776/806 2220/1007 2960/1343 24 30 40 144 39 90 180 39 90 240 39 90 144 81 90 180 81 90 240 81 90 1250/567 1250/567 1450/658 1460/663 4440/2014 6080/2758 7400/3357 9120/4137 60 80 100 60 240 240 240 240 DH-7-S DH-8-S DH-9-S DH-10-S 4.8 6.0 8.0 Current (Amperes) Number of Batteries 24.0 33.0 40.0 50.0 24.0 33.0 40.0 50.0 98 98 98 98 45 45 45 45 1632 2244 2720 3400 117 160 194 243 Width in/cm Height in/cm Depth in/cm Total System Weight lbs./kg 210/96 210/96 232/106 1 1 1 66/168 47/120 66/168 47/120 66/168 47/120 25/64 25/64 25/64 1633/741 1855/842 2247/1020 420/191 420/191 464/211 2 2 2 96/244 47/120 96/244 47/120 96/244 47/120 25/64 25/64 25/64 2835/1286 3279/1488 4063/1843 99/252 147/374 147/374 147/374 35/89 6390/2899 35/89 8630/3915 35/89 10150/4604 35/89 11980/5435 90 700/318 1 90 1300/590 2 90 1300/590 2 90 1400/635 2 72/183 72/183 72/183 72/183 E-MAIL/MODEM User can enable/disable and program alarms that will trigger messages to e-mail destinations. User can set up specific alarm events that will alert service or maintenance personnel. The system will transmit monthly and yearly tests per NFPA requirements. Bi-directional communication eases system diagnostics and data retrieval through the RS-232 serial communication port. SUMMARY FORM C CONTACT Form “C” contacts rated at 5 amps maximum at 250VAC/30VDC. Dry contact will change state when any system alarm activates. Contacts change state with the following alarms: High/low battery charger fault, near low battery, low battery, load reduction fault, output overload, high/low AC input volts, high ambient temperature, inverter fault, test failure, and optional circuit breaker trip alarm. TIME DELAY Delays retransfer of inverter to continue supplying emergency power to the normally off output for 15 minutes after the return of utility power. INVERTER ON FORM C CONTACT Form “C” dry contact that will change state when the inverter transfers to battery operation. OUTPUT CIRCUIT BREAKER Maximum output breakers available: 12 unsupervised (1pole) or 8 supervised (1-pole) for 1.5 - 5 kVA, and 24 unsupervised (1-pole) or 15 supervised (1-pole) for 6 - 16.7 kVA. Additional output or breakers available on 1.5 - 5kVA systems (additional 30 pole positions for 42 positions total; enclosure height increases to 62”). Power Rating (kVA) Heat Loss (BTU) OPTIONS AVAILABLE QTY. OUTPUT TRIP ALARM An audible and visual alarm activates when an output distribution circuit breaker is open or has tripped. MAINTENANCE BYPASS This device is internally mounted in the system and permits maintenance personnel to easily bypass the inverter and connect directly to the AC utility power. The “make before break” switch isolates the electronics or inverter system to allow performance of routine maintenance or servicing. REMOTE SUMMARY ALARM PANEL A wall mountable box containing an audible alarm and light that will activate upon any system alarm with silence switch. STATUS MONITORING CONTACTS Multiple Form “C” dry contacts capable of monitoring system and option statuses (Inverter On, Inverter Off, AC Present, High Temperature, Summary Alarm, System Bypass*, and OTA*) *Requires purchase of Maintenance Bypass and/or Output Trip Alarm options. FAST CHARGE This is a battery charger upgrade which decreases the time to recharge a fully discharged battery bank to a full charge. The recharge time is decreased from the standard 24-hour period to a 12-hour period. NORMALLY OFF OUTPUT (Standard on Series IE) This output circuit is dedicated for emergency only lighting fixtures. Emergency only loads operate during power outages and when the system is on battery back up. This option leaves selective load circuits off during normal utility power conditions. 2 ILLUMINATOR CIII-H THREE PHASE ORDERING GUIDE Example Model Number 1-EH-4-S-BA2007-F-T-S-M-R-2YW SYSTEM TYPE BATTERY TYPE OUTPUT BREAKERS5 EH - Illuminator Series “E-H” IEH - Illuminator Series “IE-H” S-Standard (VRLA) Example: B A 20 07 VOLTAGE (INPUT/OUTPUT)1 KVA/KW2 RUNTIME3 1 - 120-120 2 - 120-120/277 3 - 208-120 4 - 240-120/240 5 - 277-120 6 - 277-277 7 - 277-277/120 8 - 208-120/240 A - 208-120/208 Z - Other Voltages 1 - 1.5 2 - 2.25 3 - 3.0 4 - 3.75 5 - 5.0 6 - 6.0 7 - 8.0 8 - 10.0 9 - 12.5 10 - 16.7 (90 minutes) WARRANTY7 2YW - Factory Start-Up Extended 2-Year Electronics Warranty 5YP - 5-Year Preventative Maintenance Plan, Start-Up Included 5YW - 5-Year Electronics Warranty (includes start-up) SMP8 - Service Monitoring Plan OUTPUT OPTIONS B-Normally On N-Normally Off4 1) Only single phase voltages available. 2) KVA = KW 3) Standard battery run time is 90 minutes. 4) Normally off loads on Series E-H cannot exceed 20% of total KVA rating with any combination of H.I.D. Loads. Contact factory for clarification. 5) Maximum output breakers available: 12 unsupervised (1-pole), or 8 supervised (1-pole) for 1.5 - 5 kVA, (additional Circuit Breaker Options available, consult factory), and 24 unsupervised (1-pole), or 15 supervised (1-pole) for 6 - 16.7 kVA. Breakers provided are 20 Amps unless specified otherwise. A 2-pole breaker occupies 2 positions. 6) Maintenance bypass switch is a “make before break”. 7) Standard one year full warranty. 8) Requires Factory Start-up and E-mail/Modem options. This program will provide monitoring of the lighting inverter system by our factory service department. All monthly and yearly system tests will be reviewed by our factory service department for early warning signs of any system malfunction. Any system alarms and monthly/yearly test results will automatically be Emailed to our service department where corrective action can be taken and while under warranty, if necessary, a factory authorized service technician will be scheduled to complete any necessary repairs. This monitoring program will require a dedicated analog telephone line. 9) 15 minute retransfer time delay of normally off circuit after return of utility. A - Remote Summary Alarm Panel E - E-Mail Modem F - Fast Charge I - Inverter On Dry Contacts M - Maintenance Bypass6 N - Normally Off Output (Std. on IE)4 R - Remote Meter Panel S - Summary Fault Form C Contacts T - Output Trip5 (Supervised) Alarm V - Time Delay 15 min. (for normally off circuits only)9 VOLTAGE A-120 B-208 C-240 D-277 Z-Other AMP RATING 10, 15, 20, 25, 30, 40, 50, 60 QUANTITY 01 - 245 (List all circuit breaker requirements separately, ex: BA2007 - NA1001 ) ELECTRONICS MODULE (See chart on page 5 for dimensional details) STANDARD FEATURES Illuminator CIII-H BATTERIES (90 minutes @ full load) Power Rating (kVA) Power Rating (kW) • • Number of Batteries Efficiency (@ full load) Voltage (VDC) Audible Noise (dBA @ 1m) Current (Amperes) Heat Loss (BTU)/HR Cabinet Dimensions 1.5 2.25 3.0 3.75 5.0 6.0 8.0 10.0 12.5 16.7 3 1.5 2.25 3.0 3.75 5.0 6.0 8.0 10.0 12.5 16.7 98 98 98 98 98 98 98 98 98 98 45 102 45 153 45 204 45 255 45 340 45 408 45 544 45 680 45 850 45 1135 Width in/cm Height in/cm Depth in/cm Weight lbs/kg 90 Minute Batteries lbs/kg 30/77 30/77 30/77 30/77 30/77 53/122 53/122 53/122 53/122 53/122 47/119 47/119 47/119 47/119 47/119 76/193 76/193 76/193 76/193 76/193 25/64 25/64 25/64 25/64 25/64 25/64 25/64 25/64 25/64 25/64 215/98 230/105 235/107 240/109 280/128 605/272 640/288 785/353 805/362 885/398 296/135 444/200 592/266 740/330 888/400 1110/500 1480/666 1776/800 2220/999 2960/1332 Total System Weight lbs/kg 4 6 8 10 12 15 20 24 30 40 48 72 96 120 144 180 240 144 180 240 39 38 38 37 41 40 39 82 82 80 511/230 674/306 827/372 980/441 1168/525 1715/772 2120/954 2561/1153 3025/1361 3845/1730 • • • • • • • • UL 924 Listed System Compatible with all lighting loads including HID and LED True Sine Wave Output 98% Efficient PWM/IGBT Technology Micro-processor Control User programmable with Password Protection Automatic Self-test, Event and Alarm Logs OSHPD Special Seismic Certification, No. OSP-0258-10 High Crest Factor • • • • • • • • • • Input Circuit Breaker Main 3-pole output circuit breaker Modular Design Low audible noise 45Dba Internal Battery Circuit Breaker and/or Fuse Meets NFPA-101 for self-testing and selfdiagnostics 65kAIC Rating Load Reduction Fault Air Filters not required Internal Maintenance Bypass Switch 4 ILLUMINATOR CIII-H THREE PHASE ORDERING GUIDE Example Model Number 1-EH-4-S-BA2007-F-T-S-M-R-2YW SYSTEM TYPE BATTERY TYPE OUTPUT BREAKERS5 EH - Illuminator Series “E-H” IEH - Illuminator Series “IE-H” S-Standard (VRLA) Example: B A 20 07 VOLTAGE (INPUT/OUTPUT)1 KVA/KW2 RUNTIME3 1 - 120-120 2 - 120-120/277 3 - 208-120 4 - 240-120/240 5 - 277-120 6 - 277-277 7 - 277-277/120 8 - 208-120/240 A - 208-120/208 Z - Other Voltages 1 - 1.5 2 - 2.25 3 - 3.0 4 - 3.75 5 - 5.0 6 - 6.0 7 - 8.0 8 - 10.0 9 - 12.5 10 - 16.7 (90 minutes) WARRANTY7 2YW - Factory Start-Up Extended 2-Year Electronics Warranty 5YP - 5-Year Preventative Maintenance Plan, Start-Up Included 5YW - 5-Year Electronics Warranty (includes start-up) SMP8 - Service Monitoring Plan OUTPUT OPTIONS B-Normally On N-Normally Off4 1) Only single phase voltages available. 2) KVA = KW 3) Standard battery run time is 90 minutes. 4) Normally off loads on Series E-H cannot exceed 20% of total KVA rating with any combination of H.I.D. Loads. Contact factory for clarification. 5) Maximum output breakers available: 12 unsupervised (1-pole), or 8 supervised (1-pole) for 1.5 - 5 kVA, (additional Circuit Breaker Options available, consult factory), and 24 unsupervised (1-pole), or 15 supervised (1-pole) for 6 - 16.7 kVA. Breakers provided are 20 Amps unless specified otherwise. A 2-pole breaker occupies 2 positions. 6) Maintenance bypass switch is a “make before break”. 7) Standard one year full warranty. 8) Requires Factory Start-up and E-mail/Modem options. This program will provide monitoring of the lighting inverter system by our factory service department. All monthly and yearly system tests will be reviewed by our factory service department for early warning signs of any system malfunction. Any system alarms and monthly/yearly test results will automatically be Emailed to our service department where corrective action can be taken and while under warranty, if necessary, a factory authorized service technician will be scheduled to complete any necessary repairs. This monitoring program will require a dedicated analog telephone line. 9) 15 minute retransfer time delay of normally off circuit after return of utility. A - Remote Summary Alarm Panel E - E-Mail Modem F - Fast Charge I - Inverter On Dry Contacts M - Maintenance Bypass6 N - Normally Off Output (Std. on IE)4 R - Remote Meter Panel S - Summary Fault Form C Contacts T - Output Trip5 (Supervised) Alarm V - Time Delay 15 min. (for normally off circuits only)9 VOLTAGE A-120 B-208 C-240 D-277 Z-Other AMP RATING 10, 15, 20, 25, 30, 40, 50, 60 QUANTITY 01 - 245 (List all circuit breaker requirements separately, ex: BA2007 - NA1001 ) ELECTRONICS MODULE (See chart on page 5 for dimensional details) STANDARD FEATURES Illuminator CIII-H BATTERIES (90 minutes @ full load) Power Rating (kVA) Power Rating (kW) • • Number of Batteries Efficiency (@ full load) Voltage (VDC) Audible Noise (dBA @ 1m) Current (Amperes) Heat Loss (BTU)/HR Cabinet Dimensions 1.5 2.25 3.0 3.75 5.0 6.0 8.0 10.0 12.5 16.7 3 1.5 2.25 3.0 3.75 5.0 6.0 8.0 10.0 12.5 16.7 98 98 98 98 98 98 98 98 98 98 45 102 45 153 45 204 45 255 45 340 45 408 45 544 45 680 45 850 45 1135 Width in/cm Height in/cm Depth in/cm Weight lbs/kg 90 Minute Batteries lbs/kg 30/77 30/77 30/77 30/77 30/77 53/122 53/122 53/122 53/122 53/122 47/119 47/119 47/119 47/119 47/119 76/193 76/193 76/193 76/193 76/193 25/64 25/64 25/64 25/64 25/64 25/64 25/64 25/64 25/64 25/64 215/98 230/105 235/107 240/109 280/128 605/272 640/288 785/353 805/362 885/398 296/135 444/200 592/266 740/330 888/400 1110/500 1480/666 1776/800 2220/999 2960/1332 Total System Weight lbs/kg 4 6 8 10 12 15 20 24 30 40 48 72 96 120 144 180 240 144 180 240 39 38 38 37 41 40 39 82 82 80 511/230 674/306 827/372 980/441 1168/525 1715/772 2120/954 2561/1153 3025/1361 3845/1730 • • • • • • • • UL 924 Listed System Compatible with all lighting loads including HID and LED True Sine Wave Output 98% Efficient PWM/IGBT Technology Micro-processor Control User programmable with Password Protection Automatic Self-test, Event and Alarm Logs OSHPD Special Seismic Certification, No. OSP-0258-10 High Crest Factor • • • • • • • • • • Input Circuit Breaker Main 3-pole output circuit breaker Modular Design Low audible noise 45Dba Internal Battery Circuit Breaker and/or Fuse Meets NFPA-101 for self-testing and selfdiagnostics 65kAIC Rating Load Reduction Fault Air Filters not required Internal Maintenance Bypass Switch 4 ILLUMINATOR E/IE-H SINGLE PHASE ORDERING GUIDE Example Model Number 1-DH-4-S-C3001-C-I-S-2YW SYSTEM TYPE BATTERY TYPE OUTPUT BREAKERS DH - Illuminator Series “CIII-H” S-Standard (VRLA) Example: C XX 01 VOLTAGE (INPUT/OUTPUT)1 KVA/KW2 RUNTIME3 1 - 120/208 2 - 277/480 1 - 4.8 2-6 3-8 4 - 10 5 - 12.5 6 - 16.7 7 - 24 8 - 33 9 - 40 10 - 50 (90 minutes) 2YW- Factory Start-Up Extended 2-Year Electronic Warranty 5YW- 5-Year Electronics Warranty (Includes Start-up) 5YP- 5-Year Maintenance Plan, Start-Up Included POLE (See chart on page 3 for dimensional details) C - 3-Pole OPTIONS AMP RATING A - Remote Summary Alarm Panel C - Status Monitoring Dry Form C Contacts F - Fast Charge I - Inverter On Dry Form C Contact S - Summary Dry Form C Contact (Based on System KVA SIZE) 1) Standard input voltage is 4-Wire Wye. 3-Wire Delta Input requires external isolation transformer. 2) KVA = KW 3) Standard battery run time is 90 minutes. 4) Standard 1 year full warranty UPS ELECRONICS MODULE WARRANTY4 01 BATTERIES BATTERY MODULE TOTAL SYSTEM DIMENSIONS Power Rating (kW) Efficiency (@ full load) Voltage (VDC) Audible Noise (dBA @ 1m) Base Model Number DH-1-S DH-2-S DH-3-S 5 Weight lbs/kg Total Battery Weight lbs/kg Run Time (mins) Number of Battery Cabinets Weight lbs/kg 4.8 6.0 8.0 98 45 326 98 45 408 98 45 544 535/243 535/243 535/243 888/403 1110/504 1480/672 12 15 20 DH-4-S 10.0 10.0 DH-5-S 12.5 12.5 DH-6-S 16.7 16.7 98 45 680 98 45 850 98 45 1136 639/290 639/290 639/290 1776/806 2220/1007 2960/1343 24 30 40 144 39 90 180 39 90 240 39 90 144 81 90 180 81 90 240 81 90 1250/567 1250/567 1450/658 1460/663 4440/2014 6080/2758 7400/3357 9120/4137 60 80 100 60 240 240 240 240 DH-7-S DH-8-S DH-9-S DH-10-S 4.8 6.0 8.0 Current (Amperes) Number of Batteries 24.0 33.0 40.0 50.0 24.0 33.0 40.0 50.0 98 98 98 98 45 45 45 45 1632 2244 2720 3400 117 160 194 243 Width in/cm Height in/cm Depth in/cm Total System Weight lbs./kg 210/96 210/96 232/106 1 1 1 66/168 47/120 66/168 47/120 66/168 47/120 25/64 25/64 25/64 1633/741 1855/842 2247/1020 420/191 420/191 464/211 2 2 2 96/244 47/120 96/244 47/120 96/244 47/120 25/64 25/64 25/64 2835/1286 3279/1488 4063/1843 99/252 147/374 147/374 147/374 35/89 6390/2899 35/89 8630/3915 35/89 10150/4604 35/89 11980/5435 90 700/318 1 90 1300/590 2 90 1300/590 2 90 1400/635 2 72/183 72/183 72/183 72/183 E-MAIL/MODEM User can enable/disable and program alarms that will trigger messages to e-mail destinations. User can set up specific alarm events that will alert service or maintenance personnel. The system will transmit monthly and yearly tests per NFPA requirements. Bi-directional communication eases system diagnostics and data retrieval through the RS-232 serial communication port. SUMMARY FORM C CONTACT Form “C” contacts rated at 5 amps maximum at 250VAC/30VDC. Dry contact will change state when any system alarm activates. Contacts change state with the following alarms: High/low battery charger fault, near low battery, low battery, load reduction fault, output overload, high/low AC input volts, high ambient temperature, inverter fault, test failure, and optional circuit breaker trip alarm. TIME DELAY Delays retransfer of inverter to continue supplying emergency power to the normally off output for 15 minutes after the return of utility power. INVERTER ON FORM C CONTACT Form “C” dry contact that will change state when the inverter transfers to battery operation. OUTPUT CIRCUIT BREAKER Maximum output breakers available: 12 unsupervised (1pole) or 8 supervised (1-pole) for 1.5 - 5 kVA, and 24 unsupervised (1-pole) or 15 supervised (1-pole) for 6 - 16.7 kVA. Additional output or breakers available on 1.5 - 5kVA systems (additional 30 pole positions for 42 positions total; enclosure height increases to 62”). Power Rating (kVA) Heat Loss (BTU) OPTIONS AVAILABLE QTY. OUTPUT TRIP ALARM An audible and visual alarm activates when an output distribution circuit breaker is open or has tripped. MAINTENANCE BYPASS This device is internally mounted in the system and permits maintenance personnel to easily bypass the inverter and connect directly to the AC utility power. The “make before break” switch isolates the electronics or inverter system to allow performance of routine maintenance or servicing. REMOTE SUMMARY ALARM PANEL A wall mountable box containing an audible alarm and light that will activate upon any system alarm with silence switch. STATUS MONITORING CONTACTS Multiple Form “C” dry contacts capable of monitoring system and option statuses (Inverter On, Inverter Off, AC Present, High Temperature, Summary Alarm, System Bypass*, and OTA*) *Requires purchase of Maintenance Bypass and/or Output Trip Alarm options. FAST CHARGE This is a battery charger upgrade which decreases the time to recharge a fully discharged battery bank to a full charge. The recharge time is decreased from the standard 24-hour period to a 12-hour period. NORMALLY OFF OUTPUT (Standard on Series IE) This output circuit is dedicated for emergency only lighting fixtures. Emergency only loads operate during power outages and when the system is on battery back up. This option leaves selective load circuits off during normal utility power conditions. 2 SYSTEM SPECIFICATIONS THE ILLUMINATOR -H SEISMIC SERIES The Illuminator Series E/IE-H and CIII-H are the latest innovation in Emergency Lighting Inverter technology. The Illuminator -H series is Myers’ shaker table tested and approved expansion to the industry leading Central Emergency Lighting inverters. INPUT Voltage Input Power Walk-in Input Frequency Synchronizing Slew Rate Protection AIC Rating Power Factor These systems meet the requirements of CBC 2010 and IBC 2009 and have been shaker table tested in accordance with ICC-ES-AC-156 procedures to an SDS level of 2.5g. In addition they have received OSHPD (California Office of Statewide Health Planning and Development) Special Seismic Certification. This is the most rigid seismic standards currently being specified. SEISMIC SYSTEMS E-H, IE-H, CIII-H OUTPUT Voltage Dynamic Voltage Harmonic Distortion Overload Output Frequency Load Power Factor Inverter Overload Illuminator E-H The Illuminator Series E-H single phase uninterruptible system features sizes from 1.5-16.7 kVA/kW. This fast transfer system is designed to support all types of fixtures in emergency applications including HID, LED, and fluorescent. In addition this system can support mixed loads of all different types. The line interactive design eliminates excessive transfers to battery power. The Illuminator Series E-H transfers to inverter mode (battery power) within 2ms of loss of utility power in order to maintain the arc of an HID light. Protection Crest Factor Illuminator CIII-H Type Charger Protection Disconnect Optional Runtimes Altitude Operating Temperature Storage Temperature Relative Humidity • 1 < 10,000 feet (above sea level) without derating. Inverter: 0° to 40°C (32° to 104°F); Battery: 20° to 30°C (68° to 86°F) per UL 924. -20° to 70°C (-4° to 158°F) (electronics only). < 95% (non-condensing). GENERAL Efficiency Design Output Circuits Generator Input Control Panel STANDARD FEATURES Illuminator E/IE-H UL 924 Listed 98% Efficient PWM/IGBT Technology Micro-processor Control User Programmable Front Meter Panel Automatic Selt-test, Event and Alarm Logs OSHPD Special Seismic Certification No. OSP-0305-10 High Crest Factor Valve-regulated, sealed lead-calcium. Microprocessor controlled and temperature compensating; recharge per UL 924 spec. Automatic low-battery disconnect; automatic restart upon utility return. Series E-H / IE-H and Series CIII-H, 4.8-16.7k fuse(s); Series CIII-H, 24-50k circuit breaker / fuse(s). Extended run times available. Consult factory for additional information. ENVIRONMENTAL The Illuminator Series CIII-H three phase uninterruptible system features sizes from 4.8 to 50 kVA/kW. As with Myers’ other uninterruptible systems the CIII-H series is designed to support all lamp sources including HID and LED. Its large capacity is perfect for larger industrial and commercial applications. It can also help to provide load balancing within a facility with its wide range of sizes. • • • • • • • 120 or 277VAC, 1-phase, 2-wire + G (Series E-H / IE-H). 120/208 or 277/480VAC, 3-phase, 4-wire + G (Wye or Delta) (Series CIII-H). Contact factory for all other voltages. +/- 2% for +/-25% load step change, recovery within 3 cycles. < 3% THD for linear load. Fuse protected. 60Hz +/- 0.05Hz during emergency mode. 0.5 lag to 0.5 lead. 115% for 10 minutes; 125% for 5 minutes; 280% for 16 line cycles (Series E-H / IE-H); 280% for 12 line cycles (Series CIII-H). Series E-H / IE-H - main or distribution circuit breaker(s). Series CIII-H - optional main circuit breaker. 2.8 BATTERY Illuminator IE-H The Illuminator Series IE-H single phase standard transfer system features sizes from 1.5-16.7 kVA/kW; it is designed to support all lighting loads except HID. This includes LED, fluorescent, incandescent and quartz fixtures. This system comes standard with normally on and normally off (emergency only) outputs. 120 or 277VAC (+10% / -20%), 1-phase, 2-wire + G (Series E-H). 120 or 277VAC (+10% / -15%), 1-phase, 2-wire + G (Series IE-H). 120/208 or 277/480VAC (+10% / -15%), 3-phase, 4-wire + G (Wye) (Series CIII-H). Contact factory for all other voltages. Limiting inrush current to less than 125% of full rated load; 10 times for 1 line cycle. 60Hz, +/- 3%. 1Hz per second nominal. Input Circuit Breaker. 65k RMS symmetrical ampere short-circuit rating. 0.5 lag/lead. • • • • • • • • Input Main Circuit Breaker True Output Sine Wave Meets NFPA-101 for self-testing and selfdiagnostics Low Audible Noise 45Dba Modular Design Load Reduction Fault Air Filters not required 65 kAIC rating Metering Alarms Communications Manual Maintenance Bypass Alarm Contacts Warranty Factory Start-up 5-Year Maintenance Plan 98%. Standby UPS; PWM inverter type utilizing IGBT technology with 2ms transfer time on Series CIII-H and Series E-H and 50ms on Series IE-H. Series E-H - Normally On Circuit standard; Normally Off Circuit optional. Series IE-H - Normally On and Normally Off Circuits standard. Series CIII-H - Normally On Circuit standard; Normally Off Circuit optional. Compatible with generators. Microprocessor controlled with user friendly display, touchpad controls/functions and system status indications. Input & Output Voltage, Battery Voltage, Battery & Output Current, Output VA, Temperature, Inverter Wattage. High/Low Battery Charger Fault, Near Low Battery, Low Battery, Load Reduction Fault, Output Overload, High/Low AC Input Volts, High Ambient Temperature, Inverter Fault, Output Fault, Test Failure, and Optional Circuit Breaker Trip. RS-232 port (DB9 standard). See ordering guide for additional available options. Standard internal on Series CIII-H; optional internal on Series E-H / IE-H. Make before break. Optional summary alarm and / or status monitoring form "C" contacts. 1 year standard warranty includes all parts, labor & travel expenses within the 48 contiguous states. 10 years prorated warranty on batteries. Extended warranties, preventative maintenance and customized service plans are available. Purchase factory start-up & receive 1 additional year of electronics warranty. Purchase 5-year preventative maintenance plan & receive free factory start-up. PHYSICAL Cabinet Cooling Cable Entry Access Freestanding NEMA Type 1; reinforced and approved for seismic withstand. Forced air during emergency. Convection cooled during normal operation. No filters required. Series E-H / IE-H: top or sides on 1.5 - 5kVA; sides only on 6 - 16.7kVA. Series CIII-H: top, bottom or sides. Front ONLY is required. 6 SEISMIC CATALOG ALSO AVAILABLE FROM MYERS POWER PRODUCTS: ILLUMINATOR E-H/IE-H & ILLUMINATOR CIII-H Illuminator Series E/IE Single Phase 1.5kVA/kW to 16.7kVA/kW Illuminator Series CIII Three Phase 4.8kVA/kW to 50kVA/kW UL-924 Listed Emergency Lighting and Power Equipment 1.5kVA/kW to 16.7kVA/kW Single Phase 4.8kVA/kW to 50kVA/kW Three Phase 65kAIC Rated Shaker Table Tested to SDS Level 2.5 Illuminator Series EM Single Phase 1kVA/kW to 2.8kVA/kW Listed to CBC2010, IBC2009, AC156 44 S. Commerce Way Bethlehem, PA 18017 Phone: (610) 868-3500 Fax: (610) 868-8686 www.myerspowerproducts.com Illuminator Series CR/DR Single and Three Phase Outdoor System 3kVA/kW to 8kVA/kW ELP-0008-DS-1212 98% Efficient