Planmeca Compact i Touch * Dental unit with unit
Transcription
Planmeca Compact i Touch * Dental unit with unit
PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 1(29) Planmeca Compact i Touch * Dental unit with unit-integrated chair Planmeca Compact i dental unit is fully digital and multiprocessor controlled and all the communication between the dental unit components inside the dental unit is fully digital. All functions and features of the dental unit are thus totally software controlled. This will simplify the dental unit electronics and wiring yet having more advanced features and future feature upgrades. The instrument locations are interchangeable due to an instrument hose quick connection system. Any combination of instruments is possible and the software instantly recognizes the previous instrument settings. The patient chair is without a chair base and it is integrated to the cuspidor by a side lifting mechanism. * Planmeca Compact i Touch v2 (all markets excluding Japan and China) PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 2(29) 1. DIGITAL COMMUNICATION POSSIBILITIES Planmeca Compact i can be connected to Planmeca Romexis software. The Clinic Management module of Planmeca Romexis offers valuable tools for dental unit users: Personal user settings for unlimited number of users Real-time remote monitoring of dental unit operation Accurate information of all dental unit usage and possibility to create different kind of reports based on the gathered information for service, educational and business planning purposes Remote mass updates for dental unit software The following features of the Planmeca Compact i dental unit can be monitored and controlled through Clinic Management module: Instruments: Instrument type o Micromotor, turbine, polymerisation light, scaler, syringe Usage hours Momentary power level Power / scaling mode / time settings Auto chip blow o On/off Spray o On/off o Type (standard, dry, sterile) o Level (water / air content) Fibre light o Light level setting o On/off o Bulb-on hours Chair Activation Position Auto position settings Seat Backrest Motorized headrest (optional) Operating light On/off Intensity Suction System Hose activation Motor control Separator alerts PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 3(29) Infection control features Instrument flushing cycles Waterline cleaning cycles Suction tube cleaning cycles Service Info Error/Alert history Service modes System settings 2. APPROVALS 1. Type testing / CB-certification according to standards a) IEC 60601-1:2005 b) ISO 6875 c) ISO 7494-1 & ISO 7494-2 & ISO 10993-1 & ISO 9168 2. EMC-testing according to standard IEC 60601-1-2 3. CSA-certification according to standards: CAN/CSA-C22.2 No. 60601-1:2008 4. FDA market clearance - 510(k) premarket notification 5. CE marked according to MDD PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 4(29) 3. SUPPORT COLUMN AND INSTRUMENT CONSOLE 3.1 Support column Allows firm mounting of delivery arm, operating light, LCD monitor and Planmeca ProX The support column and the different mounting arms can be rotated simultaneously according to the user’s preferences The support column rotates gradually, 60̊ at a time, by simply lifting 3.2 Over-the-patient console arm Available as 520 mm and 340 mm Effortless to position, light movements, needle bearing mounted; also for left-handed use Spring balanced for easy lock-free height adjustment, adjustable friction Due to wide swivelling range (over 380 degrees) easy to move to assistant's side for instrument cleaning or patient entry/exit The rotation can be adjusted gradually, 8̊ at a time In case the space is limited, the delivery arm limitation is reasonable Smooth construction, no seams, all cast-metal construction. PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 5(29) 3.2.1 OP Balanced instruments PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 6(29) Integrated user interface with touch panel on the left hand side of the console reachable by the assistant side as well Small and compact to work with Open handle both on the doctor's and on the assistant's side, allows using disposable sleeves. Ergonomic, seamless and hygienic surfaces, aluminium instrument console with powder painted epoxy surfaces Easily cleanable, removable balanced instrument (doriot) arms. Mid-flexing balanced instrument arms provide long, friction-free movements for instrument hoses. The hoses are easily connected to the balanced instrument arms without any tools. The tension of the instrument arms can be adjusted without tools according to instrument weight. Autoclavable hygiene membrane for the console. Autoclavable silicone tray mats available for tray tables Optical recognition for instrument activation. Quick connect tray table is attached under the instrument console and can be de-attached easily without tools Tray table can be attached to tray arm from each side thanks to magnetic connector Tray table mounting arm swivels 360̊ PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 7(29) 3.2.2 OP hanging tube instruments PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 8(29) Integrated user interface with touch panel on the right hand side of the console. Small and compact to work with. Instrument tray table on top of the instrument console (1-, 2- or NA size) or large integrated tray at the side of the console. Autoclavable silicone tray mats available for tray tables Handle on the left hand side (integrated tray) or on both sides (top tray table) of the console. Ergonomic, seamless and hygienic surfaces. Adjustable angle of instrument holders. Quick-disconnect instrument holders for better asepsis. Optical recognition for instrument activation. PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 9(29) 3.2.3 Side delivery with hanging tube instruments PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 10(29) Side delivery arm attached to the chair base Integrated user interface with touch panel on the right hand side of the console. Effortless manoeuvring of the arm with easy friction-controlled adjustment of working height Large movement range: 225 degrees. Easy patient entry without moving of the instrument console. Console can be easily swung to the left side for cleaning of the instruments or for left-handed work. The console arm with its three joints allows effortless positioning of the instrument console Console height adjustment range 500 mm … 800 mm (19,7" … 31,5") Hose length user-adjustable. Adjustable angle of instrument holders. Quick-disconnect instrument holders for better asepsis. Optical recognition for instrument activation. Integrated swivelling tray (280 x 370 mm) with silicone mat and handle on the left hand side PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 11(29) 3.2.4 Cart with hanging tube instruments PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 12(29) Instrument console on a mobile cart. Integrated user interface with touch panel on the right hand side of the console. Easily adjustable and lockable at an ergonomic working height. Height adjustment 500-750 mm (19,7” … 29,5”) from the floor to the instrument holders. Solid and stable construction with corrosion-free cast aluminium base and extruded aluminium profile. Smooth movements on all surfaces due to large rear castors (Ø 100 mm) and easily turnable front castors. Handles on both sides of the console. Instrument tray on top of the instrument console: 1-, 2- or NA -size. Adjustable angle of instrument holders. Quick-disconnect instrument holders for better asepsis. Optical recognition for instrument activation. Foot control can be attached either to the base of the cart or the base of the unit frame. Please note that not all delivery systems are available for all markets. You can check availability from your local Planmeca distributor. PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 13(29) 3.2.5 Independent cart with hanging tube instruments Includes junction box and an instrument console on a mobile cart Does not include unit frame or patient chair. Optional quick connector for attaching the mobile cart to the junction box – mobile cart can be shared between two operating rooms (each with its own junction box). Please note that not all delivery systems are available for all markets. You can check availability from your local Planmeca distributor. PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 14(29) INSTRUMENT SELECTION 5 instrument locations (4 + syringe). Large number of available instruments for instrument console and for assistant side (see detailed list below). All instruments can be interchanged by the user without tools. Only the syringe has a fixed location on the left-hand place. Any instrument combination is possible. Instrument selection can easily be expanded to more than five due to instrument hose quick-connection system and the possibility to store up to 8 pre-programmed instrument settings. 3.3 List of available instruments Turbine instrument hose with 4-hole standard connection and fibre optic light; also a sonic scaler can be connected. 4 micromotors with ISO connection and LED light, three of them brushless. Autoclavable 6-way and 3-way syringes (straight or angled, straight available also with light) 1 USB intraoral camera on the dentist console (Touch v2) 2 S-video intraoral cameras on the dentist console (Touch) 6 piezo scalers: of which 3 with LED; scalers with external sterile water connections also available 3 LED polymerisation lights Prophy instrument Airmotor instrument hose, 4-hole connection Assistant autoclavable 6-way and 3-way syringe 3 Assistant LED polymerisation lights 2 assistant intraoral USB cameras 3.4 Instrument features All instrument hoses have quick connection for easy instrument changing and cleaning. Contamination Prevention system for turbine prevents air suck-back to instrument, connector and tubing. Non-return valves in the multiplexers prevent cross contamination. Smooth, wipe-clean, silicone instrument hoses, easy to detach. Programmable instrument air and water flow controls. Air and water pressure are controlled by software. If the pressure changes, software takes care that instrument can not be used due to the heating, if e.g. there is not enough water coming. Instrument settings are individually programmable for 8 instruments simultaneously and follow the specific hose if changed to another location. PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 15(29) Advanced Instrument Safety Logic for 4-handed dentistry: The instrument last activated by foot control will stay active until returned to the holder, thus allowing service of the other instruments. Automatic short and long instrument hose and waterline flushing system. Integrated flushing holder as a standard. Planmeca Waterline Cleaning System with Planmeca Planosil cleaning agent for waterline cleaning. 4. TOUCH PANEL Intuitive graphical user interface with fully integrated 4,3 inch touch panel Bright and sharp graphics Extremely durable due to hard glass High resolution (800 x 480 pixels) touch panel with superb contrast ratio and low energy consumption LED backlight Excellent viewing angles for both the dentist and assistant Ergonomic to use and reachable by the assistant as well Clear symbols and text guarantee easy dental unit use. Dynamic user-interface adapts to the on-going procedure. It displays only the relevant functionalities related to the selected instrument. All the instrument settings can be seen and altered in one screen. PLANMECA OY KI Planmeca Compact i Touch 26.1.2015 Page 16(29) One menu for all infection control features. User interface advises the user and gives information of the current flushing/cleaning cycle. PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 17(29) Language of the user interface can be selected. Extensive self-diagnostic help and error code system continuously monitors all the functions and the user interface guides the user how to solve a problem alone or to give an accurate diagnose for a technician by phone. Optional assistant’s control panel attached to the suction arm. PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 18(29) 5. FOOT CONTROL Electric foot control with handle operates all chair, unit and instrument functions: Instrument speed/power, proportional Horizontal operation (default) or vertical operation (optional) of the foot control pedal for instruments can be selected Spray on/off Chip blow activation to dry the cavities Instrument power selection Operating light on/off adjustment Control for chair: manual, automatic (4 + spittoon position) and stop movements. Control for motorized headrest Bowl rinsing and glass filling Freeze and save intraoral video camera images On/off for intraoral USB video camera Door open or nurse call Micromotor reverse optional; normally it is disabled for safety reasons. No wearing electrical parts like microswitches, uses more reliable capacitive system. Small size and stable cast zinc construction Symmetrical design: the instruments can be operated from mid position to either direction Clear and resistant laser markings Optional protective earth grounding terminal IPX1 classification PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 19(29) 6. TRAY TABLES 6.1 OP Balanced instruments console tray table Quick connect tray table for 1-size tray (194 mm x 296 mm) Quick connect tray table for 2-size tray (296 mm x 380 mm) Quick connect tray table for NA size (9” x 12.9”) 6.2 OP Hanging tubes console tray table Quick connect top tray table for 1-size tray (194 mm x 296 mm) Quick connect top tray table for 2-size tray (296 mm x 380 mm) Quick connect top tray table for NA size (9” x 12.9”) Integrated tray table for 2-size tray (280 x 370 mm) 6.3 Side delivery with hanging tubes console tray table Integrated rotating tray (280 x 370 mm) with silicone mat and handle on the left hand side (always included) Double tray table (rotating tray and top tray) OP tray (346 mm x 472 mm) 6.4 Cart with hanging tubes console tray table Quick connect top tray table for 1-size tray (194 mm x 296 mm) Quick connect top tray table for 2-size tray (296 mm x 380 mm) Quick connect top tray table for NA size (9” x 12.9”) OP tray (346 mm x 472 mm) PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 20(29) 6.5 Column tray table Column tray table for 1-size tray (194 mm x 296 mm) Column tray table for 2-size tray (296 mm x 380 mm) Column tray table for NA size (9” x 12.9”) 7. CUSPIDOR Integrated with chair. All connections, tubes and filters for central water supply and drain located inside the unit to improve surface hygiene. Cuspidor bowl optional, two colour options. Glass bowl can be easily removed and washed in a dishwasher (max. temperature 65°C). Glass bowl swivels for easy reach by the patient. The chair can be driven upwards when the bowl is turned over the chair, but as a safety precaution the chair stops within a certain safety margin from the bowl. Sensor for cup allows filling of the cup only when the cup is in the holder. Integrated cup stand. Cuspidor body of cast aluminium, galvanized steel, finished with baked epoxy powder coating. Fully corrosion resistant. Top cover made of PBT. All screws, tube connectors and other fittings are corrosion resistant. Safety switch inside the cuspidor prevents the up-down movements of the chair if the door is open to protect the serviceman from accidents. Automatic unit waterline flushing system. Integrated flushing holder as standard (available also for unit without bowl). Coarse filter: Filter in the suction line traps large amalgam particles. Coarse filter insert is removable for cleaning and replacement. Disposable trap filter of the bowl for added infection control. Options: Planmeca Waterline Cleaning System Planmeca Water Management System Planmeca Suction Tube Cleaning System Water heater to supply warm water for instruments and filling the glass Clean water system PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 21(29) Air quick connector Water quick connector Patient cup fill switch 8. SUCTION ARMS Suction holder Integrated activation switches: suction is automatically activated when the tube is lifted from the holder. Suction tubes and nozzles Two suction tubes as standard: vacuum-operated High Volume and Saliva Suction. Tubes are removable, with quick connectors. Adjustable suction power. Patented High Volume Suction nozzle opens automatically when tilted and closes automatically when straightened allowing temporary stopping of suction during operation if necessary. Small saliva ejector nozzle with on/off suction control switch. Suction nozzles can be removed, disassembled and autoclaved at 135 °C (275 °F). 8.1 Adjustable suction arm Tilt-up, tilt-down suction holder. Optional: second HVE or saliva hose, assistant syringe, LED polymerisation light. 8.2 Adjustable suction arm with Flexy holder Control panel with chair, nurse call / door open, operating light, bowl rinse / cup fill, Flexy button (rinsing position/usb camera activation/motorised headrest mode/Touch-Lock on,off) Optional: second HVE or saliva hose, assistant syringe, LED polymerisation light, assistant intraoral USB camera. 8.3 Left/right suction arm Tilt-up, tilt-down suction holder. Brings the suction holder to either left or right side of the chair. Allows left-to-right conversions of the unit; over-the-patient instrument console arm swings from left to right also. Optional: second HVE or saliva hose, assistant syringe, LED polymerisation light. PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 22(29) 8.4 Left/right suction arm with Flexy holder Control panel with chair, nurse call / door open, operating light, bowl rinse / cup fill, Flexy button (rinsing position/usb camera activation/motorised headrest mode/Touch-Lock on,off) Brings the suction holder to either left or right side of the chair. Allows left-to-right conversions of the unit; over-the-patient instrument console arm swings from left to right also. Optional: second HVE or saliva hose, assistant syringe, LED polymerisation light, assistant intraoral USB camera. 8.5 Chair-mounted left-right suction arm with Flexy holder Attached to the chair base; follows the up-down movement of the chair Control panel with chair, nurse call / door open, operating light, bowl rinse / cup fill, Flexy button (rinsing position/usb camera activation/motorised headrest mode/Touch-Lock on,off) Brings the suction holder to either left or right side of the chair. Optional: second HVE or saliva hose, assistant syringe, LED polymerisation light, assistant intraoral USB camera. 8.6 Chair-mounted adjustable suction arm Attached to the chair base; follows the up-down movement of the chair Brings the suction holder to either left or right side of the chair. Optional: second HVE or saliva hose, assistant syringe, LED polymerisation light. PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 23(29) 8.7 Chair-mounted adjustable suction arm with Flexy holder Attached to the chair base; follows the up-down movement of the chair Control panel with chair, nurse call / door open, operating light, bowl rinse / cup fill, Flexy button (rinsing position/usb camera activation/motorised headrest mode/Touch-Lock on,off) Brings the suction holder to either left or right side of the chair. Optional: second HVE or saliva hose, assistant syringe, LED polymerisation light. 8.8 Ergo Suction Arm (fits only the balanced instrument arm console) Attached to the instrument console. Can be used alone or together with another type of suction arm. Tilt-up, tilt-down suction holder. 9. SUCTION SYSTEM ALTERNATIVES 9.1 Dry suction system Microvac Compact, automatic separator Planmeca Microvac II. Microvac II is an automatically self-cleaning and -rinsing separating tank. Allows non-stop suction. The complete assembly is easy to service. Installation of a dry suction motor (quoted separately) is required. 9.2 Dry suction system Dürr CS1 Compact and small size Brushless motor – maintenance free Installation of a dry suction motor (quoted separately) is required Selective suction system CS1 – suction is on only in the activated suction tube thus reducing noise -> note that third suction hose can not be installed to this configuration. 9.3 Wet suction system Without separator, requires “wet”-type suction motor. Selective suction system WET – suction is on only in the activated suction tube thus reducing noise -> note that third suction hose can not be installed to this configuration 9.4 Dry suction system Dürr CAS1 amalgam separator Includes both water/air separator and centrifugal amalgam separator (collects 97,5 % of amalgam) PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 24(29) Selective suction system CAS1 – suction is on only in the activated suction tube thus reducing noise -> note that third suction hose can not be installed to this configuration 9.5 VS/A – Compatible Suction System Planmeca offers unit model which is compatible with a VS or VS/A suction motor. VS suction motor includes an integrated automatic water/air separator and VS/A motor additionally a centrifugal amalgam separator (collects 97,5 % of amalgam). Selective suction system VS/A – suction is on only in the activated suction tube thus reducing noise -> note that third suction hose can not be installed to this configuration 9.6 No suction system For 12 o'clock suction concepts. 10. SUCTION TUBE CLEANING SYSTEM Optional Integrated in the cuspidor. Orotol Plus disinfectant is poured into the dozing cup, and the unit mixes the correct concentrate automatically. The tubes are filled with the diluted solution and left to immerse in it for 2 minutes killing all the microbes. Available for selective suction systems. PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 25(29) 11. ARM ASSEMBLY ALTERNATIVES Operating light adapter post (support column) Attached vertically to the console arm or directly to cuspidor. Allows installing Planmeca SingLED operating light. Does not affect or limit the movements of the instrument console arm: the console arm can be operated also when placed on the left-hand side. Mounting arm for LCD monitor Attached horizontally to the support column Swivels horizontally and allows adjusting monitor viewing angle The support column and the LCD monitor arm can be rotated simultaneously according to the user’s preferences Mounting arm for Planmeca ProX Attached horizontally to the support column Available with or without light post and/or LCD monitor 12. CONSTRUCTION, COATING AND COLOUR OF UNIT Solid cast aluminium, corrosion free construction. Electroplated or hot galvanized steel parts. Baked epoxy powder finish on all external metal parts is scratch and chip resistant and easy to clean. Unit colour: White RAL 9016 12.1 Solenoids All solenoids have acid-proof stainless steel plungers. 12.2 Installation Junction area inside the cuspidor - no separate junction box needed. Electric power supply with protection circuits. Indicator light fuses and master on/off switch. Optional satellite junction box or top installation cover available. 12.3 Filters Filter for compressed air (25 µm) with automatic water condensate separator. Filter for water (25 µm). 5 µm filter in the water line before unit recommended (quoted separately). PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 26(29) 13. TECHNICAL INFORMATION The unit is pre-set at the factory to one of the three different mains voltage settings. The possible voltage settings are: * 100 VAC * 115 VAC * 220…240 VAC The voltage setting for the complete unit can be altered by re-wiring a voltage jumper on the main control PCB. Mains frequency 50 or 60 Hz (cycles) independent of the mains voltage setting Power consumption The idle power consumption is less than 300 VA. Maximum power consumption is 1200 VA. Water inlet pressure 3 bar to 9 bar (43 psi to 130 psi) Air inlet pressure 5,5 bar to 9 bar (80 psi to 130 psi) Suction line pipe ø min. 50 mm (2”) Drain line pipe ø min. 50 mm (2”) Weight About 130 kg All Planmeca products are manufactured according to Quality Standard ISO 9001: ISO 9001 Quality System Standard, Certificate No. 95-HEL-AQ-166 PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 27(29) 14. PLANMECA COMPACT PATIENT CHAIR 14.1 Chair integrated to the unit Designed for dental care of both adults and children. Wide, stable support for back and arms. Slim upper backrest for better access Side-lifting mechanism together with a thin backrest provides exceptional access for operator and assistant. Headrest-to-cuspidor distance 750…620 mm (depending on headrest slide position). Allows for easy manoeuvring from the left side of the patient. Compensating movement of backrest provides ideal comfort for the patient. Swivel point of backrest has been positioned high to hip level to enable tilting without movement between the human back and the seat. Backrest surface is following the body surface during the movements. Double articulating prosthetic headrest allows optimum patient positioning, with hygienic design. Anatomical seat angulation. Integrated elbow support. Chair can be driven to the horizontal position. Multiprocessor controlled. Pre-programmed working positions with memory, 4 positions and a spittoon position. Trendelenburg position Automatic glass filling, bowl rinsing and operating light off -function when rinsing position is activated. By pressing the rinsing position key the second time the bowl will be rinsed again, the chair returns to the previous position and operating light comes on automatically if it was on before. Automatic and manual chair functions from both the unit touch panel and foot control. Automatic/manual function separated by time delay. Powered by two low-noise electric motors, one for the seat and the other for the backrest. Lifting capacity 135 kg (297 lbs) Dimensions: seat length 112 cm (44 1/10”), seat width 55 cm (21 1/2”). Seat height: min 350 mm (13 3/4”), max 810 mm (32”). Backrest height 57 cm (22 1/2”), backrest width 62 cm (24 2/5”). Backrest casting 20 mm / 0,80 inch and total backrest thickness with the upholstery 50 mm / 2 inches Setting of the chair backrest up to 65°. Headrest slide range 130 mm (5”). PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 28(29) Powder paint finish is scratch and chip resistant and not affected by surface disinfectants. Solid cast aluminium construction and painted inner surfaces guarantee a sturdy, corrosion free design, stainless steel screws. Electroplated or hot galvanized steel parts. Standard colour RAL 9016 white. Armrests and surgical IV armrest available as an option. 14.2 Safety features Backrest is free to move upwards so that the operator's knees cannot be trapped when the chair is lowered. Electronically controlled overload protection. Chair movement can be stopped in an emergency by operating any function on the foot control or any chair control key on the control panel. Legrest can freely move upwards if obstructed. Chair movements are disabled if instruments are operated. The chair can be driven upwards when the bowl is turned over the chair, but as a safety precaution the chair stops within a certain safety margin from the bowl. 14.3 Automatic legrest Optional feature. Movement synchronized with the backrest movements – patients have easier access to the chair and positioning of the patient's back and legs is easier. Backrest movement range: 0° (horizontal)...65° Legrest movement range: (0°) -11°...-90° When the legrest moves synchronized with the backrest (ranges: BR 0°...65°, LR -11°...-90°), the patient can easily be brought from supine position to the sitting exit position. PLANMECA OY Planmeca Compact i Touch KI 26.1.2015 Page 29(29) When the legrest is locked at position 0° or at position -11°, the chair can be lifted and lowered within the complete height adjustment range. * Position 3: Trendelenburg position 14.4 Upholsteries Comfy upholstery: comfortable and firm foam covered with seamless artificial leather. Ultra Relax upholstery: viscoelastic memory cell foam covered with Ultraleather. Adjusts to different body shapes. 14.5 Headrest Oval and rectangular headrest cushions. The double articulated headrest enables the positioning of the patient’s head and provides good visibility into the oral cavity. Pressing one single release allows two independent adjustments for upper and lower jaw visibility. The headrest cushion provides good support for the patient and holds the head firmly in position. 14.6 Motorized headrest Hands-free use from foot control. Can be programmed with chair positions. 14.7 Armrests Optional right and left armrests. Right side armrest is movable to allow easy patient entrance and exit. Covered with the upholstery material and available in all colours. Surgical IV armrest as an option.
Similar documents
Planmeca Compact a
External infection control made easy Smooth and uniform surfaces of Planmeca Compact a guarantee easy cleaning and impeccable external infection control, crucial for safe dental treatment. Powder-p...
More information