ELECTRIC HEATER
INSTRUCTIONS MANUAL
ECOHEAT MODEL
Keep this manual with you after your unit has been installed,
you may need it for further technical information.
Congratulations! You’ve just purchased a new EcoHeat tankless
water heater, and will soon begin enjoy the benefits of “going
tankless”.
Use this manual to guide you through the installation and operation,
as it contains important safety tips and instructions.
Please take the time to thoroughly read and understand
the
safety and installation manual in its entirety before you attempt
to install your new EcoHeat tankless water heater.
If you are not familiar with basic plumbing and electricity we highly
recommend that you consult the services of a professional
to assist you with this installation.
02
INSTALLATION GUIDE
04
INSTALLATION
04
RESTRICTIONS
06
ENERGY SAVING TIPS
06
OTHER POWER REQUIREMENTS
07
HOW TO USE
08
TEMPERATURE CONTROL
08
QUICK INSTALLATION GUIDE
09
STEPS TO RESET THE HEATER
11
WARRANTY POLICY - US AND CANADA
12
CUSTOMER SERVICE
14
OTHER PRODUCTS
14
03
IMPORTANT!
Working around electricity requires proper skills and knowledge – and should not be
performedbysomeonewhoisnotfamiliarortrainedinthistrade.Therefore,weHIGHLY
recommend that you solicit the services of a licensed and qualified
“Electrician/Plumber”familiarwithtanklesswaterheaterinstallation.
All electrical work and setting the unit to the wall should be completed before any
electricalwiringconnections.
IMPROPER INSTALLATION CAN CAUSE INJURY OR EVEN DEATH.
I) WALLFIXING
Any residue or dirt in the pipes may cause internal damage to the unit. We
recommend installing a sediment filter before the entry of water to the heater.
Hard water or water with high levels of minerals and alkali can cause damage to
this unit. When this is the case, we recommend the use of a (non-salt) water
softening system.
III) ELECTRICITY
- Install a fuse box or switch (“breaker") for exclusive use of the heater. Based
on the power of the model obtained using the cable for your unit according to
the power and model purchased. Find a detailed guide to the power and cable
type used in the table below. Connect the ground, as indicated in the Electrical
Code.
Find a detailed guide to the power and cable type used in the table below.
Connect the ground, as indicated in the Electrical Code.
MODEL
MAXIMUM AMPERAGE
CABLE
DSK 70
27 A
10 AWG
DSK 90
38 A
8 AWG
DSK 110
44 A
8 AWG
- Turn off the power or running water.
- Mark the position of the points of the 3 screws. Note that we recommend leaving 6
inches clearance (free) around the heater, thereby facilitating the proper installation
and maintenance.
- The heater must beinstalled vertically and secured with 3 screws using the“drill
hole template” included with this heater.
- Set the heater at the points where the screws should go, use the adapters and
screws provided.(viewphotos)
Once installed the heater, let the water flow through the unit before turning on
electricity. When all connections are satisfactorily prepared install the heater cover.
With the insulated container off and flow modifier (optional) fully open, the faucet
must be opened fully to get maximum water flow at the exit. This is necessary to
ensure that the water tank is full before turning your energy is an essential step to
protect the resistance.
II) PLUMBING
Remember: Run the water before turning on electricity.
- Use s tainless steel flexible hose or copper tubing from ½ " t o enter and leave
the water heater. (Right side water inlet, hot water outlet, left.) When you have
water pipes reduce the manother size to ½".
NOTE: The electrical supply is not turned on until all the pipes and the installation is
complete.
- Do not use PVC, CPVC or plastic supply lines to connect the unit. A pipe 16"of
copper or stainless steel must be connected to the input and output of the
heater.
These heaters are of the closed type (closed system with no ventilation pressure)
suitable for fitting to the normal input of cold water with a maximum of 150 PSI (10
bar). They must be fitted with a pressure valve adjacent to the entrance.
- Connect the isolation valve at the entry inlet pipe of the heater and make sure
you install a rubber washer. Do not apply excessive force to tighten connectors.
The heater should be installed as close as possible to the point of use, because the
distance to be run the hot water temperature affect. If a shower is used for the
heater should be installed outside the shower stall/area.
When installed in a location that could freeze the heater must be isolated and
drained.
Be sure to clean the pipes before connecting the heater to the main line, clean
all the impurities of the pipe allowing water to flow for a few minutes, check for
leaks.
04
05
- DO NOT expose the unit to freezing temperatures. Do not use an input water
temperature over 90 degrees F or 32.2 degrees Celsius.
- We recommend that you install the unit under the sink in main bathrooms or
utility areas. This will allow for lower amperage usage and a reduced heat loss
from longer pipe runs.
- DO NOT restrict the flow of water entering the unit.
- DO NOT use the unit if water ceases to flow during use. If the outer case or cover
is loose, your heater will not work correctly. An improperly secured cover can cause
injury or electric shock.
- For additional savings, reduce the water flow valve at the inlet of the heater so
the temperature increases.
- This unit is designed for indoor use only.
WARNING! THIS APPLIANCE MUST BE PROPERLY GROUNDED!
NEVER OPERATE THIS HEATER WITHOUT THE COVER!
1. The heater should only be connected to a supply 200/240VAC.
WARNING!
When you turn the unit can get extremely hot water. Take proper safety precautions
to avoid being hurt or be burned by water.
- Ensure that all electrical connections are adequately protected to prevent shock,
overheating and damage.
- The fuse does not give personal protection against electric shock. Improving
electrical safety: A single ground fault breaker (GFCI), 30-50 Amp (depending on
configuration and requirements) or a residual current device (RCD) must be
installed on this circuit.
- This unit requires a single circuit. Other electrical equipment such as fans, pumps,
etc. must be on separate circuits.
- Turn off the power switch manually or when unused for extended periods of time.
- The unit must be certified by an electrician from the time they installed for an
additional year.
NOTE: Improper use or installation will void the warranty.
- When possible, install the heater in the most central locations, nearest to the point
of use (where hot water is needed, e.g., shower, faucets, etc.)
- Adjust heater temperature settings (located on the front panel of the heater) to the
desired output temperature you desire. Lowering the power setting will save
energy, but will have a lower output water temperature.
06
2. The use of a plug and outlet is NOT RECOMMENDED for this unit.
3. The heater must be connected to its own independent electrical circuit. It must be
connected to a main circuit, SPUR, OR PLUG OUT lighting circuits.
4. Make sure that your panel The service has a rate of 30/60 ampere main switch
(the intensity depends on the configuration of the temperature used) If necessary,
contact your energy provider for general use or a licensed electrician to check the
service required.
5. The switch must be accessible and clearly identifiable, but out of reach of a
person with a fixed shower. Except for the cable that has a cable of a key switch,
and must be placed so that it is not possible to touch the switch body standing in a
bath or shower.
6. The unit circuit should be separated from other circuits, at least twice the
diameter of the cable duct.
7. It is essential that the conditions of each site are evaluated by a qualified
electrician to determine the correct cable size and permissible circuit length.
MODEL
RECOMMENDED
SWITCH
MAXIMUM
AMPERAGE
@240vV
POWER
MINIMUM
PRESSURE
TO ACTIVATE
TEMPERATURE
INCREMENT
MAXIMUM
PRESSURE
TO
ACTIVATE
DSK 70
1 X 60 A
27 A
6.5 Kw
5 PSI
Nature - 75 ºF
degree
150 PSI
DSK 90
1 X 40 A
24 - 38 A
9 Kw
5 PSI
Nature - 75 ºF
degree
150 PSI
DSK 110
1 X 50 A
44 A
10 Kw
5 PSI
Nature - 75 ºF
degree
150 PSI
07
IMPORTANT!
The size of the switch and wire gauge must meet all local, state, provincial and
national electrical codes in your area - these are just guidelines that apply to most
installations. Some codes require the use of electrical substations for the
installation panel, especially when heater is not mounted within line of sight of the
main electrical panel. Wiring must be sized to maintain a voltage drop of less than
3% under load.
There are real dangers involved in improper installation of any electrical appliance.
Improper installation will void the warranty of your unit. Failure to follow proper
installation procedures there is a risk of injury or death.
Local codes "Most counties, cities and states have specific codes governing the
installation of electrical equipment. You need to know the code and permit
requirements in your community before installing your tankless water heater.
6. Place both ands of the inlet and outlet pipes,
IMPORTANT: Use black boards as shown in the illustration to avoid spillage
of water.
7. Press well to seal the board completely black.
8. Use a flexible stainless steel or cooper, this would facilitate the installation and
make it lighter and simpler.
9. Open tha water inlet valve of the heater. check for spill any team at both
entrances. If there is any type of stroke, please correct it.
10. Will there be any close faucet hot water side.
11. Place the front cover of the heater.
12. Make sure the two screws at the bottom of the box.
13. Place the heater button on the top.
- Open the hot water tap and the tankless hot water heater will activate, thus
producing hot water. Mix hot with cold water to achieve the desired output
temperature.
14. Connect the plug on the receptacle.
15. At the conclusion of all the steps correctly, you’re ready to enjoy the benefits of
the heater.
- The speed of water passing through the heater unit, which determines the water
temperature in a given environment (for example, slowing the flow of water will
increase the temperature. A faster flow will result in a lower output temperature.)
- In cooler regions or cooler seasons of the incoming water temperature will cause
a variation in the output temperature. The temperature settings allow for
compensation of seasonal changes.
For illustrations, see the photos on the next page.
1. Use a #8 AWG wire for electrical connection.
2. CAUTION: Verify that the cables are tight.
3. Use the illustrated cardboard to facilitate the centralization of the heater and then
have to scuttle the points in order to support the screws.
4. Place expansions and screws, remove the card and enter the furnace or central
body on the wall using screws. After having placed the main body check this nut.
5. Verify that the central heater.
08
09
1. Unplug the power cord and electrical circuit of the equipment.
2. Unscrew the two screws that are at the bottom of the deck.
3. Remove the temperature controller button.
4. Remove the cover carefully.
5. Open the hot water pen and let the water run about 10 seconds.
6. Tighten the two buttons are indicated in the illustration (see Figure 6) and press
each one until it clicks.
10
11
Dear Customer,
You have 30 days from your purchase date to register in Marey Heater Warranty
Program in our web site www.marey.com. Registration after 30 days voids
Warranty. Warranty applies only due to manufacturing defects. Damage caused
by customer due to a bad installation, exposure to extreme climate conditions,
heaters with broken seal or unarmed interior are not covered by warranty. We
highly recommend you to install your unit according to the Instructions Manual and
with a specialized plumber / electrician.
Marey warranty cover parts and labor during its lifetime. The warranty does not
cover reimbursement.
If the heater undergoes any changes under warranty and had been repaired within
this period, it is your responsibility to contact Marey to notify the new serial number.
3. Manufacturer shall not be liable for any water damage arising, directly or indirectly,
from any defect in the water heater component part(s) or from its use.
4. Manufacturer shall not be liable under this warranty if:
a) The water heater or any of its component parts has been subject to misuse,
alteration, neglect or accident, or;
b) The water heater has not been installed in accordance with the applicable local
plumbing and/or building code(s) and/or regulation(s), or;
c) The water heater has not been installed in accordance with the printed
manufacturer's Instructions, or;
d) The water heater is not continuously supplied with potable water.
e) The possible damages caused for labor or other expenses incurred in the removal of
the product or any expense shall.
5 YEARS WARRANTY COVERAGE
Marey Heater guarantees this water heater to the original owner of the water heater
at the original installation location against defects in material for the periods
specified below.
WARRANTY PERIOD
TO REQUEST A REPAIR UNDER WARRANTY
- The warranty seal should be intact
- Original purchase receipt will be required
1st month of purchase: cover parts, labor and shipping back and forth.
1st year of purchase: cover parts and labor. Customer should ship the unit to
Marey Heater Corp Central Services in Puerto Rico in order to get it repaired.
2nd to 5th year of purchase: cover parts. Customer should ship the unit to Marey
Heater Corp Central Services in Puerto Rico in order to get it repaired.
Note: Damage caused by exposure to freezing conditions is not covered by the
warranty.
Note: Damage caused by scale formation is not covered by the warranty.
- EXCLUSIONS
1. THIS LIMITED WARRANTY SHALL BE THE EXCLUSIVE WARRANTY MADE
BY THE MANUFACTURER AND IS MADE IN LIEU OF ALL OTHER
WARRANTIES, EXPRESSED OR IMPLIED (WHETHER WRITTEN OR ORAL),
FOR OTHER SELLERS OR DISTRIBUTORS.
- Your unit should be registered in the warranty
program within 30 days of purchase
GAS AND ELECTRIC HEATERS
WARRANTY
COVERAGE*
PARTS LABOR SHIPPING
1 Month
---
1 Year
2-5 Years
---
---
* If you bought your unit trough e-commerce, please contact Marey Heater directly.
DO NOT contact your seller.
2. Manufacturer shall not be liable for incidental, consequential, special or
contingent damages or expenses arising, directly or indirectly, from any defect in
the water heater or the use of the water heater.
12
13
Marey Heater offers an excellent Customer Service. If you have any question
about our product, information about how to install a unit, about our Warranty
Services or if you want to share with us a suggestion, get in touch with us!
Please visit our website to get to know more about other Marey products.
Customer Service:
1-877-727-0277
[email protected]
A Toll Free number for all your needs!
14
ECOHEAT
POWER PAK
SANTON
AQUAMATIC
MINI MAREY
POWER GAS
Delbrey Street, 211
San Juan, Puerto Rico
00912
Tel. 1-787-727-0277
TELÉFONO LIBRE DE COSTO / TOLL FREE
1-877-727-0277
www.marey.com