Keep this manual with you after your unit has been installed, you
Transcription
Keep this manual with you after your unit has been installed, you
ELECTRIC HEATER INSTRUCTIONS MANUAL ECOHEAT MODEL Keep this manual with you after your unit has been installed, you may need it for further technical information. Congratulations! You’ve just purchased a new EcoHeat tankless water heater, and will soon begin enjoy the benefits of “going tankless”. Use this manual to guide you through the installation and operation, as it contains important safety tips and instructions. Please take the time to thoroughly read and understand the safety and installation manual in its entirety before you attempt to install your new EcoHeat tankless water heater. If you are not familiar with basic plumbing and electricity we highly recommend that you consult the services of a professional to assist you with this installation. 02 INSTALLATION GUIDE 04 INSTALLATION 04 RESTRICTIONS 06 ENERGY SAVING TIPS 06 OTHER POWER REQUIREMENTS 07 HOW TO USE 08 TEMPERATURE CONTROL 08 QUICK INSTALLATION GUIDE 09 STEPS TO RESET THE HEATER 11 WARRANTY POLICY - US AND CANADA 12 CUSTOMER SERVICE 14 OTHER PRODUCTS 14 03 IMPORTANT! Working around electricity requires proper skills and knowledge – and should not be performedbysomeonewhoisnotfamiliarortrainedinthistrade.Therefore,weHIGHLY recommend that you solicit the services of a licensed and qualified “Electrician/Plumber”familiarwithtanklesswaterheaterinstallation. All electrical work and setting the unit to the wall should be completed before any electricalwiringconnections. IMPROPER INSTALLATION CAN CAUSE INJURY OR EVEN DEATH. I) WALLFIXING Any residue or dirt in the pipes may cause internal damage to the unit. We recommend installing a sediment filter before the entry of water to the heater. Hard water or water with high levels of minerals and alkali can cause damage to this unit. When this is the case, we recommend the use of a (non-salt) water softening system. III) ELECTRICITY - Install a fuse box or switch (“breaker") for exclusive use of the heater. Based on the power of the model obtained using the cable for your unit according to the power and model purchased. Find a detailed guide to the power and cable type used in the table below. Connect the ground, as indicated in the Electrical Code. Find a detailed guide to the power and cable type used in the table below. Connect the ground, as indicated in the Electrical Code. MODEL MAXIMUM AMPERAGE CABLE DSK 70 27 A 10 AWG DSK 90 38 A 8 AWG DSK 110 44 A 8 AWG - Turn off the power or running water. - Mark the position of the points of the 3 screws. Note that we recommend leaving 6 inches clearance (free) around the heater, thereby facilitating the proper installation and maintenance. - The heater must beinstalled vertically and secured with 3 screws using the“drill hole template” included with this heater. - Set the heater at the points where the screws should go, use the adapters and screws provided.(viewphotos) Once installed the heater, let the water flow through the unit before turning on electricity. When all connections are satisfactorily prepared install the heater cover. With the insulated container off and flow modifier (optional) fully open, the faucet must be opened fully to get maximum water flow at the exit. This is necessary to ensure that the water tank is full before turning your energy is an essential step to protect the resistance. II) PLUMBING Remember: Run the water before turning on electricity. - Use s tainless steel flexible hose or copper tubing from ½ " t o enter and leave the water heater. (Right side water inlet, hot water outlet, left.) When you have water pipes reduce the manother size to ½". NOTE: The electrical supply is not turned on until all the pipes and the installation is complete. - Do not use PVC, CPVC or plastic supply lines to connect the unit. A pipe 16"of copper or stainless steel must be connected to the input and output of the heater. These heaters are of the closed type (closed system with no ventilation pressure) suitable for fitting to the normal input of cold water with a maximum of 150 PSI (10 bar). They must be fitted with a pressure valve adjacent to the entrance. - Connect the isolation valve at the entry inlet pipe of the heater and make sure you install a rubber washer. Do not apply excessive force to tighten connectors. The heater should be installed as close as possible to the point of use, because the distance to be run the hot water temperature affect. If a shower is used for the heater should be installed outside the shower stall/area. When installed in a location that could freeze the heater must be isolated and drained. Be sure to clean the pipes before connecting the heater to the main line, clean all the impurities of the pipe allowing water to flow for a few minutes, check for leaks. 04 05 - DO NOT expose the unit to freezing temperatures. Do not use an input water temperature over 90 degrees F or 32.2 degrees Celsius. - We recommend that you install the unit under the sink in main bathrooms or utility areas. This will allow for lower amperage usage and a reduced heat loss from longer pipe runs. - DO NOT restrict the flow of water entering the unit. - DO NOT use the unit if water ceases to flow during use. If the outer case or cover is loose, your heater will not work correctly. An improperly secured cover can cause injury or electric shock. - For additional savings, reduce the water flow valve at the inlet of the heater so the temperature increases. - This unit is designed for indoor use only. WARNING! THIS APPLIANCE MUST BE PROPERLY GROUNDED! NEVER OPERATE THIS HEATER WITHOUT THE COVER! 1. The heater should only be connected to a supply 200/240VAC. WARNING! When you turn the unit can get extremely hot water. Take proper safety precautions to avoid being hurt or be burned by water. - Ensure that all electrical connections are adequately protected to prevent shock, overheating and damage. - The fuse does not give personal protection against electric shock. Improving electrical safety: A single ground fault breaker (GFCI), 30-50 Amp (depending on configuration and requirements) or a residual current device (RCD) must be installed on this circuit. - This unit requires a single circuit. Other electrical equipment such as fans, pumps, etc. must be on separate circuits. - Turn off the power switch manually or when unused for extended periods of time. - The unit must be certified by an electrician from the time they installed for an additional year. NOTE: Improper use or installation will void the warranty. - When possible, install the heater in the most central locations, nearest to the point of use (where hot water is needed, e.g., shower, faucets, etc.) - Adjust heater temperature settings (located on the front panel of the heater) to the desired output temperature you desire. Lowering the power setting will save energy, but will have a lower output water temperature. 06 2. The use of a plug and outlet is NOT RECOMMENDED for this unit. 3. The heater must be connected to its own independent electrical circuit. It must be connected to a main circuit, SPUR, OR PLUG OUT lighting circuits. 4. Make sure that your panel The service has a rate of 30/60 ampere main switch (the intensity depends on the configuration of the temperature used) If necessary, contact your energy provider for general use or a licensed electrician to check the service required. 5. The switch must be accessible and clearly identifiable, but out of reach of a person with a fixed shower. Except for the cable that has a cable of a key switch, and must be placed so that it is not possible to touch the switch body standing in a bath or shower. 6. The unit circuit should be separated from other circuits, at least twice the diameter of the cable duct. 7. It is essential that the conditions of each site are evaluated by a qualified electrician to determine the correct cable size and permissible circuit length. MODEL RECOMMENDED SWITCH MAXIMUM AMPERAGE @240vV POWER MINIMUM PRESSURE TO ACTIVATE TEMPERATURE INCREMENT MAXIMUM PRESSURE TO ACTIVATE DSK 70 1 X 60 A 27 A 6.5 Kw 5 PSI Nature - 75 ºF degree 150 PSI DSK 90 1 X 40 A 24 - 38 A 9 Kw 5 PSI Nature - 75 ºF degree 150 PSI DSK 110 1 X 50 A 44 A 10 Kw 5 PSI Nature - 75 ºF degree 150 PSI 07 IMPORTANT! The size of the switch and wire gauge must meet all local, state, provincial and national electrical codes in your area - these are just guidelines that apply to most installations. Some codes require the use of electrical substations for the installation panel, especially when heater is not mounted within line of sight of the main electrical panel. Wiring must be sized to maintain a voltage drop of less than 3% under load. There are real dangers involved in improper installation of any electrical appliance. Improper installation will void the warranty of your unit. Failure to follow proper installation procedures there is a risk of injury or death. Local codes "Most counties, cities and states have specific codes governing the installation of electrical equipment. You need to know the code and permit requirements in your community before installing your tankless water heater. 6. Place both ands of the inlet and outlet pipes, IMPORTANT: Use black boards as shown in the illustration to avoid spillage of water. 7. Press well to seal the board completely black. 8. Use a flexible stainless steel or cooper, this would facilitate the installation and make it lighter and simpler. 9. Open tha water inlet valve of the heater. check for spill any team at both entrances. If there is any type of stroke, please correct it. 10. Will there be any close faucet hot water side. 11. Place the front cover of the heater. 12. Make sure the two screws at the bottom of the box. 13. Place the heater button on the top. - Open the hot water tap and the tankless hot water heater will activate, thus producing hot water. Mix hot with cold water to achieve the desired output temperature. 14. Connect the plug on the receptacle. 15. At the conclusion of all the steps correctly, you’re ready to enjoy the benefits of the heater. - The speed of water passing through the heater unit, which determines the water temperature in a given environment (for example, slowing the flow of water will increase the temperature. A faster flow will result in a lower output temperature.) - In cooler regions or cooler seasons of the incoming water temperature will cause a variation in the output temperature. The temperature settings allow for compensation of seasonal changes. For illustrations, see the photos on the next page. 1. Use a #8 AWG wire for electrical connection. 2. CAUTION: Verify that the cables are tight. 3. Use the illustrated cardboard to facilitate the centralization of the heater and then have to scuttle the points in order to support the screws. 4. Place expansions and screws, remove the card and enter the furnace or central body on the wall using screws. After having placed the main body check this nut. 5. Verify that the central heater. 08 09 1. Unplug the power cord and electrical circuit of the equipment. 2. Unscrew the two screws that are at the bottom of the deck. 3. Remove the temperature controller button. 4. Remove the cover carefully. 5. Open the hot water pen and let the water run about 10 seconds. 6. Tighten the two buttons are indicated in the illustration (see Figure 6) and press each one until it clicks. 10 11 Dear Customer, You have 30 days from your purchase date to register in Marey Heater Warranty Program in our web site www.marey.com. Registration after 30 days voids Warranty. Warranty applies only due to manufacturing defects. Damage caused by customer due to a bad installation, exposure to extreme climate conditions, heaters with broken seal or unarmed interior are not covered by warranty. We highly recommend you to install your unit according to the Instructions Manual and with a specialized plumber / electrician. Marey warranty cover parts and labor during its lifetime. The warranty does not cover reimbursement. If the heater undergoes any changes under warranty and had been repaired within this period, it is your responsibility to contact Marey to notify the new serial number. 3. Manufacturer shall not be liable for any water damage arising, directly or indirectly, from any defect in the water heater component part(s) or from its use. 4. Manufacturer shall not be liable under this warranty if: a) The water heater or any of its component parts has been subject to misuse, alteration, neglect or accident, or; b) The water heater has not been installed in accordance with the applicable local plumbing and/or building code(s) and/or regulation(s), or; c) The water heater has not been installed in accordance with the printed manufacturer's Instructions, or; d) The water heater is not continuously supplied with potable water. e) The possible damages caused for labor or other expenses incurred in the removal of the product or any expense shall. 5 YEARS WARRANTY COVERAGE Marey Heater guarantees this water heater to the original owner of the water heater at the original installation location against defects in material for the periods specified below. WARRANTY PERIOD TO REQUEST A REPAIR UNDER WARRANTY - The warranty seal should be intact - Original purchase receipt will be required 1st month of purchase: cover parts, labor and shipping back and forth. 1st year of purchase: cover parts and labor. Customer should ship the unit to Marey Heater Corp Central Services in Puerto Rico in order to get it repaired. 2nd to 5th year of purchase: cover parts. Customer should ship the unit to Marey Heater Corp Central Services in Puerto Rico in order to get it repaired. Note: Damage caused by exposure to freezing conditions is not covered by the warranty. Note: Damage caused by scale formation is not covered by the warranty. - EXCLUSIONS 1. THIS LIMITED WARRANTY SHALL BE THE EXCLUSIVE WARRANTY MADE BY THE MANUFACTURER AND IS MADE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED (WHETHER WRITTEN OR ORAL), FOR OTHER SELLERS OR DISTRIBUTORS. - Your unit should be registered in the warranty program within 30 days of purchase GAS AND ELECTRIC HEATERS WARRANTY COVERAGE* PARTS LABOR SHIPPING 1 Month --- 1 Year 2-5 Years --- --- * If you bought your unit trough e-commerce, please contact Marey Heater directly. DO NOT contact your seller. 2. Manufacturer shall not be liable for incidental, consequential, special or contingent damages or expenses arising, directly or indirectly, from any defect in the water heater or the use of the water heater. 12 13 Marey Heater offers an excellent Customer Service. If you have any question about our product, information about how to install a unit, about our Warranty Services or if you want to share with us a suggestion, get in touch with us! Please visit our website to get to know more about other Marey products. Customer Service: 1-877-727-0277 [email protected] A Toll Free number for all your needs! 14 ECOHEAT POWER PAK SANTON AQUAMATIC MINI MAREY POWER GAS Delbrey Street, 211 San Juan, Puerto Rico 00912 Tel. 1-787-727-0277 TELÉFONO LIBRE DE COSTO / TOLL FREE 1-877-727-0277 www.marey.com