Underfloor Heating Systems Technical Installation Guide
Transcription
Underfloor Heating Systems Technical Installation Guide
TIG7 Underfloor Heating Systems JUNE 2012 EFFECTIVE: 1ST JUNE 2012 Technical Installation Guide June 2012 CONTENTS How to use this guide ............................................................................................................03 INTRODUCTION About Polypipe Underfloor Heating........................................................................................04 An overview of Polypipe Underfloor Heating Systems .............................................................06 Selecting the right Polypipe Underfloor Heating System .........................................................07 System selection ....................................................................................................................08 Design service ........................................................................................................................09 Polypipe Registered Installer Network .....................................................................................10 What you can expect from your installer ................................................................................11 Guide to floor coverings for underfloor heating systems.........................................................12 INSTALLING THE SYSTEM Solid Floor..............................................................................................................................14 Floating Floor .........................................................................................................................18 Suspended Floor ....................................................................................................................20 Modular Heating Panels (MHP)...............................................................................................24 Overlay™...............................................................................................................................30 Overlay™ Lite ........................................................................................................................38 CONNECTING & CONTROLLING THE SYSTEM Connecting to heat source .....................................................................................................40 Manifolds ..............................................................................................................................41 Water temperature controls ...................................................................................................42 Room temperature controls ...................................................................................................44 Single room applications ........................................................................................................50 System commissioning ...........................................................................................................52 TECHNICAL DATA Heat output tables .................................................................................................................54 General system information ...................................................................................................55 FAULT FINDING CHARTS Hydraulic fault finding chart ...................................................................................................56 Electrical fault finding chart (master connecting box)..............................................................57 STANDARDS Accreditations, standards and guarantees ..............................................................................58 FORMS Design enquiry form ..............................................................................................................59 Polypipe Underfloor Heating products, excluding manifolds and control products, are covered by a 50 year guarantee*, which protects against defects in materials or manufacture of the heating system from date of purchase. This guarantee only applies if the system is installed in accordance with the manufacturer’s recommendations contained within the Technical Installation Guide (the latest version of which can be found at www.ufch.com), and is used in a normal domestic operation. This document should be read in conjunction with all other documentation supplied with Polypipe products. If you have any queries please contact our Technical Department on 01709 770000. *Full terms and conditions for Polypipe heating products 50 Year Guarantee are available at www.ufch.com. 02 HOW TO USE THIS GUIDE Important notice: This publication is provided as a comprehensive guide on how to install Polypipe Underfloor Heating Systems. It is an important document as we cannot accept any liability, or honour any guarantee, for products and systems that have not been installed in accordance with our published instructions. From time to time our installation advice may be updated at which time previous printed copies will become out of date. The latest version of our installation advice, including a downloadable version of the current Technical Installation Guide, can be found at our trade website, www.ufch.com. Selecting the right system This guide is intended for competent trained plumbing and heating installers and we assume that you will have already specified your system of choice before consulting this publication for installation advice. Basic information on selecting the right system is provided in this guide. For more detailed guidance refer to our Design & Specification Guide or visit our trade website at www.ufch.com or consumer website at www.freeyourwalls.com. Navigating the Technical Installation Guide Having read the general introductory sections at the front of the guide, ensure that you have selected the correct system for your floor type and project. Read the guide to floor coverings to ensure that your system is compatible with your floor type. Technical data Towards the back of this guide you will find technical data such as heat output tables, pipe data and general system information as well as useful forms to use with our Product Selectors and System Design Service. Additional information Should you have any questions at any time, or require any kind of technical support, call our Technical Support team on 01709 770000. Online assistance is available at www.ufch.com, our comprehensive website for installers, developers and merchants. As well as information on technical advice and product benefits, you can find useful case studies and details of Polypipe stockists. Video instructions on underfloor heating installation are also available to view. For Polypipe Registered Installers we have created a dedicated members area on our consumer site, www.freeyourwalls.com. Here you can access full marketing resources, update your web profile and see great promotional offers from our network partners. Next, choose your selected underfloor heating system type from the section “Installing the system” and follow the step by step instructions. Everything should be straightforward but remember that the Polypipe Technical Support team is always ready to help answer any questions you may have. Whichever Polypipe Underfloor Heating System you are installing you will need to refer to the information provided in the section “Connecting and controlling the system”. This section provides all you need to know about manifolds and controls, connecting your system to an appropriate heat source and commissioning the system. 03 ABOUT POLYPIPE UNDERFLOOR HEATING Polypipe is one of Europe’s largest manufacturers of specialist plastic plumbing, heating, waste and drainage products. Our market leading underfloor heating product range has been continuously developed and improved with frequent innovative additions, the latest of which are Modular Heating Panels (MHP) - a revolutionary solution for suspended floor applications, and Overlay™ Lite - a lightweight floor panel to complement our innovative over floor heating range. Polypipe is a member of the Underfloor Heating Manufacturers’ Association (UHMA), who set and enforce standards for materials, design and installation of underfloor heating systems - standards that we embrace within every aspect of our range. Polypipe Underfloor Heating Systems have been designed with specifiers, installers and users in mind. Our systems combine ease of installation with reliable long-term performance, and we hold a range of stock ready for prompt dispatch. Unique to the Polypipe service proposition is our room and house packs concept. Recognising that underfloor heating systems are difficult to specify using individual components, we created a range of over 150 pre-set combinations that can be ordered as complete kits. By simply specifying key variables such as floor type and room size the right pack can be specified in minutes. It’s as easy as . We have even created a unique online product selection tool. PRODUCT SELECTOR for UFCH & OVERLAY™ Following recent innovative product introductions, we have categorised our range into 3 groups in order to make selecting even more instinctive: 04 With a long established reputation for product quality and value, backed by our strict trade-only distribution policy, Polypipe has become the clear leader in the underfloor heating category. Recent innovations ensure the Polypipe range is the widest available from a single manufacturer, including traditional underfloor heating systems for every floor type as well as the innovative MHP and Overlay™ products. Polypipe Underfloor Heating Systems are ideal for every application, including new build, self build, renovation and home improvement projects. Whole house, single floor and single room projects are equally catered for in our extensive product offering. Whatever job you are undertaking, Polypipe has the product to suit. Polypipe is a recognised and respected brand, and is well established as the system of choice for domestic homes by many installers. All Polypipe Underfloor Heating Systems are supplied as a complete system, and require no additional components for installation. Polypipe Underfloor Heating Systems are rigorously tested, and comply with (or exceed) all relevant UK standards. We use an integrated flexible plumbing system, incorporating polybutylene pipes and a range of push-fit fittings. The systems are also designed for use with copper pipes, allowing the integration of rigid pipes when necessary. Easy installation Flexible approach Polypipe Underfloor Heating Systems have been designed with ease of installation in mind. Innovative product designs ensure minimal disruption to existing heating and electrical supplies during installation. As our systems are compatible with standard central heating boilers, connectivity is also streamlined. Polypipe Underfloor Heating Systems can be installed up to 20% quicker than radiators. Polypipe Underfloor Heating Systems use the flexibility of polybutylene pipe to provide a solution for all house and room types. We also have a range of unique and innovative products, including the Zonal Regulation Unit (ZRU) which is an excellent enabler allowing underfloor heating systems to be incorporated into single rooms or refurbishment projects with minimal disruption to existing heating and electrical supplies. Polypipe Underfloor Heating Systems are installed in one stage, eliminating the need for a time consuming second fix. Underfloor heating components are much easier to manoeuvre on site than large, bulky radiators; reducing handling issues and potential damage. Unlike radiators, there is also very little theft value during installation. For more information on our single room applications see pages 50 and 51. Details of each type of Polypipe Underfloor Heating System can be found on page 6. Maintenance free Once installed, a Polypipe Underfloor Heating System is virtually maintenance free. There are no joints in the pipe work within the flooring, significantly reducing the possibility of leaks. Polypipe Underfloor Heating products are subjected to rigorous testing and meet a number of exacting standards, full details of which can be found on page 58. All our manufacturing processes are monitored and controlled in accordance with the international quality standard BS EN ISO 9002. Choosing underfloor heating also eliminates a number of general maintenance and decoration requirements, normally associated with radiators, such as painting the radiator or removing it to paint the wall. Demonstrating the utmost confidence in product performance, and providing our customers with peace of mind, Polypipe Underfloor Heating Systems are covered by the Polypipe 50 year guarantee (full details can be found at www.ufch.com). Easy to control Polypipe manufactures a range of water and room temperature control solutions, allowing you to source a complete, integrated system from a single supplier. The range includes a number of control products, with options to suit a variety of lifestyle patterns, and the abilities to control different rooms independently. Excellent service At Polypipe we understand that selecting the right solution for each application involves detailed consideration. This is why we offer extensive customer service support, including free system design and full technical support if any problems arise. We want to ensure that your installation runs smoothly from the beginning and our technical support staff can assist you with any questions you might have. During installation we offer: UÊ Pre-project training at one of our training centres UÊ Pre-project training by distance learning UÊ On-site assistance We also provide an extensive back up service: UÊ Technical representation available to discuss systems in general and particular projects UÊ www.ufch.com UÊ ÜÜÜ°vÀiiÞÕÀÜ>ðV UÊ Technical Installation CD UÊ Specialist Technical Hotline on 01709 770000 Energy efficient Underfloor heating systems can be more economical to run than radiator based systems. As they demand a low temperature rise output from the boiler, they are ideally suited to achieving maximum economy from a condensing boiler or heat pump. However, they are just as efficient with higher temperature heat sources, for example solar and solid fuel, where the correct water temperature can be set at the point of distribution. Full details of Polypipe control products can be found on pages 44 to 49. 05 AN OVERVIEW OF POLYPIPE UNDERFLOOR HEATING SYSTEMS Polypipe has the widest available range of underfloor heating systems, with a product available for every conceivable floor type or residential heating project. With Polypipe, underfloor heating is not restricted to new build developments or self build projects. Our unique Overlay™ system is particularly well suited to single room projects such as kitchens, bathrooms, conservatories, extensions and loft conversions. Polypipe Modular Heating Panels (MHP) were developed to provide an innovative and practical solution to installing underfloor heating into upper floors. The notes below provide a brief overview of the methodologies employed to install underfloor heating systems for various floor types. Refer to the overview on the page opposite. Full installation instructions for each floor type can be found in the section titled ‘Installing the system’ on pages 14 to 39. Solid Floor Polypipe Underfloor Heating can be permanently built into solid concrete or screeded floors. As required by current Building Regulations, insulation is built into the floor directly beneath the unique Polypipe lightweight plastic floor panel. The heating pipe is simply slotted into the panel and then permanently covered by the screed. Suitable for all floor coverings, solid floor systems can incorporate 15mm or 18mm pipe. The floor panels form a simple grid for the quickest possible pipe laying and provide a precise guide to achieve the minimum bending radius. Panel castellations are set at exact centres and hold the pipe against movement when screeding. The floor panel holds the pipe above the insulation allowing full screed surround. Optimum screed depth is 65mm from the panel base, i.e. 40mm from the pipe top. Insulation below and at the edges of the floor screed is required by Building Regulations. Edge insulation also acts as an expansion joint. Floating Floor When installed in floating floors, Polyplumb pipe is simply pressed in to the pre-formed heat spreader plate, which sits in grooves within the floating floor insulation panel. The floating floor system is then covered with 18mm chipboard sheeting. Suitable for all floor coverings, floating floor systems can incorporate 15mm or 18mm pipe. 06 Suspended Floor For installations in suspended floors, Polypipe Underfloor Heating uses double heat spreader plates. Alternatively, pipes can be laid on top of insulation between joists. Standard tongue and groove floorboards are laid on top of the system. Suspended double heat spreader plate systems use 15mm pipe. Modular Heating Panels (MHP) Modular Heating Panels offer a revolutionary new way to solve the issue of installing underfloor heating into upper floors. MHP is available in two widths and two lengths to fit all standard joist spacings. All components and circuitry is pre-configured into the panels which are simply installed between the joists, linked together and connected to the manifold. Overlay™ Overlay™ allows underfloor heating to be installed into existing spaces quickly, easily and practically. This unique system is supplied with a choice of patented low profile panels to suit all types of floor coverings. Overlay™ is laid over existing solid or timber floors. SELECTING THE RIGHT POLYPIPE UNDERFLOOR HEATING SYSTEM Polypipe Underfloor Heating Systems Product selection: Typical applications and features New build Existing floor Underfloor SOLID FLOOR All floor coverings High mass system Typical ground floor or beam and block construction FLOATING FLOOR Over floor SUSPENDED FLOOR All floor coverings except natural wood / thick laminates OVERLAY™ LITE OVERLAY™ Lightweight floor coverings Tiles or natural wood Larger areas Wet areas Multiple rooms Lightweight construction No wet trades required SUSPENDED FLOOR MODULAR HEATING PANELS All floor coverings All floor coverings Fit from above Fit from above / below Traditional joists Traditional heat source Traditional or engineered joists Traditional or renewable heat sources 07 SYSTEM SELECTION PRODUCT SELECTOR for UFCH & OVERLAY™ Polypipe has removed the mystique from specifying the correct underfloor heating solution for a given project and the need to calculate all of the individual components required. Our unique Product Selector, which is available online at www.ufch.com and also at www.freeyourwalls.com, uses a simple 3 step process to calculate your requirements using basic project data that you provide. The system includes a range of over 150 pre-configured systems that contain all the parts and components you need. Once you have determined the correct pack for your project it can be ordered under a single item code via your merchant. PRODUCT SELECTOR for UFCH & OVERLAY™ To use the Polypipe Product Selector you first decide whether the project is a single room, a whole house solution, or requires a bespoke design. You then simply input data for each room, providing floor type and room size to calculate the required pack. All packs have a single order code and include all the necessary flooring materials, pipe, distribution (manifolds, ZRU, etc.) and water temperature controls. To select the appropriate solution, choose from the following options: Room packs Room packs are designed for single room applications: i.e. kitchens, bathrooms, conservatories, loft conversions and extensions. This range of underfloor heating packs contain all the flooring and control equipment required for a single project, in solid floor, our traditional Overlay™ and our NEW Overlay™ Lite systems. All room packs have a maximum heat output of 100W/m2. House packs House packs provide you with a quick and easy way to select and order from our range of underfloor heating products, without the need to submit a design. The packs are designed for solid, floating or suspended (double heat spreader plate) systems, OverlayTM and OverlayTM Lite projects. Packs can be applied to all new build or renovation properties that fall into the following criteria: UÊ ,ÃÊÀiµÕÀ}ÊÕ«ÊÌÊÇä7É2 UÊ ÇäÊ7É2 - Solid 200mm centres, floating and suspended floors 100 W/m2 - Solid 100mm centres, OverlayTM and OverlayTM Lite floors UÊ *À«iÀÌiÃÊLÕÌÊÌÊVÕÀÀiÌÊÕ`}Ê,i}Õ>Ìà 08 Design services For projects that fall outside the scope of the room packs or house packs, Polypipe offers a fully bespoke system design service. To utilise this facility, simply complete the enquiry form on page 59, or at www.ufch.com, and submit your drawings to Polypipe. You will then receive a complete design and component list for the project. Modular Heating Panels (MHP) Our revolutionary new MHP panels, designed to make underfloor heating easier to install between ceiling joists for upper floor suspended floor applications, have their own product selector, which is also available online at www.ufch.com or www.freeyourwalls.com. DESIGN SERVICE For projects that fall outside the scope of the room packs or house packs, Polypipe offers a fully bespoke system design service. To utilise this facility, simply complete the enquiry form on page 59, or at www.ufch.com, and submit your drawings to Polypipe. You will then receive a complete design and component list for the project. Our comprehensive system design service includes: UÊ -ÞÃÌiÊ`iÃ}]ÊVÕ`}Ê i>ÌÊÃÃÊV>VÕ>Ìà for residential applications UÊ ÀVÕÌÊi}Ì Ã UÊ ÀVÕÌÊ«ÀiÃÃÕÀiÊÃÃiÃÊ>`ÊÛiVÌià UÊ ÜÊÀ>ÌiÊÃiÌÌ}ÃÊ«iÀÊVÀVÕÌ UÊ ÕÊ«À`ÕVÌÊ>ÌiÀ>ÊëiVwV>Ì Installation service UÊ *Ài«ÀiVÌÊÌÀ>}Ê>ÌÊÌÀ>}ÊViÌÀi UÊ *Ài«ÀiVÌÊÌÀ>}ÊLÞÊ`ÃÌ>ViÊi>À} UÊ "ÃÌiÊ>ÃÃÃÌ>ViÊvÊÀiµÕÀi`Ê`ÕÀ}Ê«ÀiVÌÊÃÌ>>Ì Backup service UÊ /iV V>ÊÀi«ÀiÃiÌ>ÌÊ>Û>>LiÊÌÊ`ÃVÕÃÃÊÃÞÃÌià in general and particular projects UÊ 7iLÃÌiÊ>`ÊvÀ>ÌÊÊ UÊ -«iV>ÃÌÊ/iV V>ÊÌiÊÊ01709 770000 09 POLYPIPE REGISTERED INSTALLER NETWORK When you select Polypipe as your underfloor heating brand of choice, we want you to know you will receive a professional installation service. To ensure you get this peace of mind we have developed a nationwide network of Registered Installers who have the skills and experience to install our systems to the highest standards. Finding a Polypipe Registered Installer Finding a member of the Polypipe Registered Installer Network couldn’t be easier. Simply visit www.freeyourwalls.com and locate the stockist finder quick link at the bottom left hand corner of the home page. You will now see a list of members of the Polypipe Registered Installer Network in your area, with the closest shown first. To find out more about a particular installer, click on ‘Installer Details’ next to their entry to display their profile. The installer’s profile will be displayed, showing details of their project expertise, areas covered, number of employees and recent projects. You can also check their location via the Google Maps link. Enter your postcode, select ‘Installer’ and click on the ‘Find’ button (installers can also use this function by selecting ‘Stockist’ to search for local stocking merchants). 10 Once you have selected one or more installers you can email them directly from the website or use the displayed contact details to get in touch by phone. WHAT YOU CAN EXPECT FROM YOUR INSTALLER Polypipe Registered Installers are vetted based on their experience and expertise in installing Polypipe Underfloor Heating Systems. Your contract is directly with the installer, and we cannot provide any guarantee in respect of their work. We do, however, provide extensive warranties on our products. In the unlikely event that you experience a problem with any aspect of your experience with a Polypipe Registered Installer you should notify us on 01709 770000. All Polypipe Registered Installers are provided with a personalised certificate to prove their authenticity. You should be shown this but if not, please ask to see it. Choosing the right system Your installer will assess your needs, based on the floor and room type, size and the way in which you want the heating controls to operate. Using our unique product selectors, your Polypipe Registered Installer will be able to select exactly the right system configuration for your underfloor heating system. Providing you with a quotation We also provide our Registered Installer Network with a personalised quotation tool. Your installer will be able to use the results of the needs assessment and product selection process to produce you a tailored quotation for all aspects of your underfloor heating system, including all parts and labour. Getting started Once you have agreed the quotation, your installer will provide you with a contract setting out all aspects of the project, confirming the costs and also detailing things like access requirements. Once you have agreed a start and completion date and both signed the contract, the materials will be ordered and your system installation will be underway. Design service For complex projects that may fall outside the scope of our product selector and pack system we offer a bespoke design service. This can be accessed by your Registered Installer or self builders can use it directly. A design service form is included in the back of this brochure. Further information If, at any stage, you require any further information please get in touch with our underfloor heating team at the Doncaster address on the back cover of this brochure or call our technical support line on 01709 770000. Want to join the network? If you are an installer and are interested in joining the Polypipe Registered Installer Network, visit www.ufch.com/installers/become-an-installer.php. Complete the form and we will send you an application pack by return. 11 GUIDE TO FLOOR COVERINGS FOR UNDERFLOOR HEATING SYSTEMS Underfloor heating systems will work efficiently with any floor covering, as long as it is well insulated underneath. However, each covering has different thermal conduction properties, and harder surfaces offer better conductivity and, therefore, better heat output rates. The following notes provide some guidance on each type of covering. Carpet and underlay Stone and ceramic tiles, marble or flagstones Suitable for all Polypipe Underfloor Heating Systems: The nature and thickness of the carpet underlay is fundamental in determining good heat transfer. The most popular underlay type is sponge with a waffle pattern moulded into the underside. These allow good heat transfer. Felt and rubber crumb underlay should be avoided. These products can seriously reduce the effectiveness of an underfloor heating system, as they insulate the floor surface and prevent heat transfer. The TOG value of carpet and underlay should be available from the respective manufacturer. For optimal system performance choose an underlay with a maximum TOG value of approximately 0.5. The maximum TOG value of carpet should be approximately 1.0 to 1.5. 12 Suitable for all Polypipe Underfloor Heating Systems: These types of floor finishes are usually cold underfoot. However, with floor heating they are transformed into warm, comfortable surfaces. Each of these finishes is essentially brittle and it is imperative that the design of the supporting floor structure is stable and rigid to prevent cracking. It is recommended that flexible adhesives and grout be used. Vinyl Timber Suitable for all Polypipe Underfloor Heating Systems: Suitable for Polypipe solid floor and suspended floor systems: Sheet vinyl is sensitive to long term exposure to heat. There are two categories of vinyl; one is limited to constant temperatures of around 26°C and the other to 30°C. Check the floor surface temperature indicated by your vinyl supplier for compatibility with underfloor heating. If unsure contact the Polypipe hotline or the vinyl floor manufacturer. Concerns regarding the effect of heat on a timber floor are misplaced. The more important issue is the floor moisture content. Timber floors should be laid at a moisture content of 10-11%, which when heated will reduce to 8-9%, and cause only a very small amount of shrinkage. The floor will re-absorb some moisture when the heating is not operating and the moisture content will increase to 12-13%. Further details on installing timber floors over Polypipe Underfloor Heating Systems can be found on page 17. Laminate Suitable for all Polypipe Underfloor Heating Systems: Laminate flooring should be laid on roll type floor leveller, rather than the rigid panel type. Movement that occurs must be accommodated by an expansion gap around the floor deck. 13 SOLID FLOOR Polypipe Underfloor Heating in solid or screeded floors incorporates the unique Polypipe screeded floor panel. The lightweight plastic floor panels nest for easy storage and carrying. Polypipe has the perfect solution for installing underfloor heating into solid or screeded floors. Utilising our unique lightweight plastic floor panels, which are quick and easy to cut to size, it is possible to fit Polypipe Underfloor Heating into any shaped room. The panels are laid above pre-installed insulation and the system includes edging insulation strip to ensure maximum performance and efficiency. Polypipe solid floor panels form a simple grid to ensure the fastest possible pipe laying and also provide a precise guide for the pipe, ensuring that the minimum pipe bending radius is achieved. U U U U 14 Polypipe Underfloor Heating Systems can be used with the following solid floor constructions: Sand & cement screed (4:1 mix) Pumped screed systems (anhydrite, etc.) Fine or heavy concrete Polymer modified screeds Pre-installation requirements The sub floor must be swept clean and be free from mortar residues. Maximum coverage per circuit Step 3: The floor panels are laid over the pre-installed insulation Key design and installation information Maximum heat output Recommended design flow temp Maximum circuit length Fitting the floor panels and should be overlapped at the edges. Approx. 100W/m 50°C 100m (15mm pipe) 120m (18mm pipe) 12m2 at 100mm centres 22m2 at 200mm centres 30m2 at 300mm centres* *(18mm pipe only) 2 Material requirements (approx) Pipe Floor plate usage Edging insulation strip Conduit pipe 8.2m/m2 at 100mm centres 4.5m/m2 at 200mm centres 3.3m/m2 at 300mm spacing* *(18mm pipe only) 1 plate/m2 allowing for cutting (Actual 1·2m2/plate) 1.1m/m2 2m/circuit Installation NOTE: The ½ castellation should overlap the ¾ castellation. The first panel should be laid with the ½ castellation edge against the wall. Fitting insulation Panels can be cut by simply using a saw or snips or it can Step 1: be overlapped to the nearest castellation fit. In accordance with Part ‘L’ of the current Building Regulations, Floor panels should not be used at the base of the manifold a suitable layer of insulation material should be included within as pipes need to be closer together than the floor panels allow. the floor construction. It is the responsibility of the architect or builder to ensure compliance. However, in all instances insulation Pipes around this area should be secured using pipe clips which can must be installed beneath the underfloor heating system in order also be used intermittently to secure the clip plate to the insulation. to ensure that any downward heat loss does not exceed 10W/m , When a pumped (liquid) screed is to be used it is essential that all of in accordance with BS EN 1264. the panel joints are made correctly and that no panels are allowed to Fitting the edge insulation strips simply ‘butt-up’ as this may allow the screed to penetrate below the 2 Step 2: Using edge insulation strip allows the free expansion of the floor screed. The insulation strip should be installed around all perimeter walls and fixed constructions such as columns, steps and access doors. Edge insulation strip is bent at 90° near to the base to form a double sided self-adhesive strip which bonds the floor plates to the floor insulation. Edge insulation strip should be fitted in addition to perimeter insulation required by Building Regulations. underfloor heating system and cause the panels to rise up. Similarly the panels should be firmly secured around the perimeter of the room using staples so as to prevent possible risk of the panels lifting. Preparing the pipe Step 4: You will need to remove the coil from the bag, leaving the shrink wrap on, uncoiling from centre of the coil. Laying the pipe Step 5: Once you have completed laying the solid floor panels the pipe can be fitted starting at the manifold position in line with the pre-designed centres. 15mm and 18mm pipe can be laid at 100mm or 200mm centres as required, 18mm pipe can also be laid at 300mm centres. The minimum bend radius is achieved by encircling two castellations for a 90° bend or three castellations for a 180° bend (see diagrams on next page). 15 90° 180° Step 6: Circuits being laid at 100mm or 200mm centres must be laid in a spiral configuration. The first loop of pipe should be laid around the perimeter of the area to be covered by that circuit. The next loop of this circuit should be laid either 200mm from the first loop of pipe for 100mm centres or 400mm from the first loop of pipe for 200mm centres. 18mm pipe installation formation Where 300mm centre spacing is require (18mm pipe systems only) a meander pattern can be used. The pipe simply crosses the room from one side to the other encapsulating 3 castellations at each return bend. Step 7: Continue to loop the pipe into the centre of the panels leaving enough space to form a double return (‘S’ shape in the centre of the loop). Conduit pipe A 400mm length of conduit pipe should be fitted over the underfloor heating pipe in any situation where damage may be caused to the pipe i.e. where the pipe passes through internal walls or doorways, where the pipe emerges through the floor up to the manifold or where the pipe passes through either an expansion or day joint. Preformed long radius bends can also be used to provide a neater solution if required. A section of conduit pipe 400mm long should be fitted around the heating pipe where the pipe passes through the edge insulation strip, e.g. room to room, or through expansion joints within the floor. Conduit pipe should also be used where the pipe leaves the floor adjacent to the manifold. This can be threaded down the pipe after the pipework has been installed. Step 8: Now work back out from the centre by filling the space between the inwardly spiralling loop of the primary circuit ensuring the pipe is laid at the correct spacing centres. 16 Pipe Conduit Insulation Sub floor Finishing Expansion joint BS EN 1264-4 recommends that an expansion joint is constructed in stone and ceramic finished screeds for every 40m2 of floor area at a maximum length of 8m and an aspect ratio of 2:1. Timber floors Many people are concerned by the effect of heat on a timber floor, but this concern is misplaced. The important factor is the floor moisture content. An expansion joint is also required in long narrow areas such Timber floors can be laid directly over the screed at a moisture as corridors, etc. content of 10-11% which during the heating season will reduce The image below shows a typical arrangement where the pipes to 8-9% and may cause a small amount shrinkage. pass through either an expansion or a day joint. A strip of edge The floor will re-absorb some moisture when the heating is not insulation is used to provide the expansion capacity. operating and the moisture content will increase to 12-13%. Application of timber floors over solid floor systems Where solid oak flooring is to be laid on a solid floor, joists can be fitted at 1m centres to provide a fixing point for the boards. Insulation, solid floor panels and pipe can be laid between the joists and screed laid level with the top of the joists (see diagram below). For further information regarding floor screeding requirements for underfloor heating systems please refer to BS8204-1 or the BISRIA Guide: Screeds with Underfloor Heating. Testing Step 9: Once the pipes circuits have been installed and pressure tested the screed cover can be applied. Care should be taken to ensure that the screed is tightly compacted around the pipe to ensure that no voids are present. The system should remain under pressure (6 bar) in order to prevent the risk of any damage being caused to the walls of the pipe whilst the screed is being applied. Laying the screed Step 10: The overall quality and thickness of a sand and cement screed should meet the requirements of BS8204-1 which stipulates that in domestic or light commercial applications a minimum thickness of 65mm should be used. The thickness of alternative coverings, such as anhydrite or polymer modified screeds, may differ depending Individual circuits of pipe are then laid between each set of joists with care being taken to ensure the screed is completely dry prior to fitting the solid oak covering (see diagram below). on construction requirements. This information should therefore be provided by the specialist screed manufacturer/supplier. After the screed has been laid the floor should be covered with a membrane to retard the drying out process, particularly in warm weather. The floor should be allowed to cure and dry naturally until full strength is reached in accordance with relevant British Standards and manufacturers’ instructions (approx 30 days for sand and cement and concrete floors). Under no circumstances should the underfloor heating system be used to artificially dry/ cure the screed as this could cause the screed to crack and seriously undermine the integrity of the floor construction. Once the screed has fully cured the underfloor heating system can be switched on and the manifold flow temperature slowly increased up to the calculated design temperature. Screed Timber floor covering Solid floor plate Joist at 1m spacings 17 FLOATING FLOOR The Polypipe floating floor system is designed for use in applications where a solid floor installation is not suitable due to structural weight limitations or where a ‘dry build’ floor option is required. Suitable for use in either new build or existing properties, the floating floor panels can be installed directly on top of both solid and timber floors. The 50mm thick high density polystyrene panels have a thermal value of 0.036W/mK and can be used to enhance the thermal insulation requirement of the floor structure as required under current Building Regulations. However, care should be taken when installing floating floor panels on top of a primary insulation layer to ensure that excessive deflection does not occur in the final floor construction. 18 It is therefore recommended that any other insulation materials used below the floating floor panels are of a high density construction (100kN/m2 @ 10% compression min). Pre-installation requirements The sub floor must be swept clean and be free from mortar residues. Key design and installation information Maximum heat output Recommended design flow temp Maximum circuit length Maximum coverage per circuit Approx. 70W/m2 60°C 80m (15mm pipe) 100m (18mm pipe) 25.8m2 at 300mm centres (15mm pipe) 30m2 at 300mm centres (18mm pipe) Laying the pipe Step 3: Once you have completed laying the floating floor panels and heat spreader plates the pipe can be fitted into the pre-formed grooves of the heat spreader plate. Start at the manifold position and use the grooves in the floating floor panel to loop round the entire room. The maximum circuit length is 80m using 15mm pipe or 100m using 18mm pipe. Pipe should be laid in the pattern shown below. Material requirements (approx) Pipe Floating floor panel Single spreader plate 3.1m/m2 at 300mm centres 1 panel/1.4m2 3 plates/m2 Installation Laying the floating floor panels Step 1: Lay the 1200 x 1200 x 50mm floating floor panels directly over the entire floor area to be heated, ensuring the panel grooves are aligned. The panels can be cut to fit where necessary. Polyplumb barrier pipe Single heat spreader plate Insulated floating floor panel A void in the insulation is often retained around the edge of the room to allow for distribution pipes to be laid from the room to the manifold. NOTE: Areas of potential high point loading, e.g. under heavy furniture kitchen units and appliances, will require additional floor support. Timber battens (50mm x 50mm) should be positioned between the floating floor panels and notched to allow the passage of pipes. Testing Step 4: Once the pipe circuits have been installed and connected to the manifold the system should be pressure tested to 6 bar for a minimum of 1 hour before the timber floor covering is laid. It is recommended that the system remains under pressure whilst the flooring is laid. Finishing Laying the spreader plates Step 2: Single heat spreader plates that have pre-formed grooves at 300mm centres need to be laid on top of the floating floor panels. These plates ensure an even spread of heat across the floor area and hold the pipe firmly within place in the floating floor panel. The room can then be finished by fitting 18mm or 22mm tongue and groove sheets of chipboard, glued on the edge, over the floating floor system. Mark the position of the pipe where door thresholds or carpet strip are to be installed. When laying a ceramic or stone floor covering ensure that any deflection in the floor is minimised. It is recommended that a slip mat or uncoupling membrane is used rather than a second layer of wood. 19 SUSPENDED FLOOR Designed for use in timber suspended or battened floors the Polypipe suspended floor system uses aluminium double heat spreader plates to transmit the heat evenly across the finished floor surface. Suitable for joist widths of 300mm to 450mm the spreader plates are simply fixed to the joist using small nails or staples. The pipe is then run in to the preformed grooves of the panels which are designed to hold the pipe securely at 225mm average centres. 450mm 1000mm A layer of insulation below the panels will ensure that almost all of the heat generated passes up in to the room. The Polypipe suspended floor system is also suitable for use with ‘sprung’ flooring systems as used in sports halls, etc. 20 250mm Pre-installation requirements Key design and installation information Any other services, such as drainage or electrical wiring, should be installed below the insulation layer. Maximum heat output Recommended design flow temp Maximum circuit length Maximum coverage per circuit double heat spreader plates (15mm) The floor joists then need to be notched or drilled in accordance with Building Regulations. This facilitates the passage of the pipe between the joist gap to allow the entry and exit of the pipe to and from the room. Approx. 70W/m2 60°C 80m (15mm pipe) 17m2 at 225mm average centres Material requirements (approx) Pipe Double heat spreader plates 4.5m/m2 Heat spreader plates 2 plates/m2 Installation The spreader plates can then be fixed evenly across the joists and in accordance with your installation design. Laying the pipe Step 3: Once the spreader plates have been fixed in place the pipe can be fitted in to the grooves in a meander pattern. It is recommended that the flow pipe from the manifold be taken to the furthest point of the room when installing the circuit as this ensures that sufficient heat is provided around the perimeters of the room. Fitting insulation Step 1: Return Flow Before installing a suspended floor system it is necessary to insulate between the joists. Polypipe recommend that a rigid polystyrene or foam insulation material is used. Double heat spreader plate Fitting the spreader plates Step 2: The insulation layer should fit tightly between the joists directly below the spreader plate to ensure that the spreader plate is supported and therefore remains in contact with the underside of timber floor covering. This is necessary to eliminate any air gaps or draughts between the underfloor heating system and the floor. Pipe Joists notched to accept pipe returns Care should be taken when installing the pipe to ensure the spreader plates are not pushed downwards and away from the underside of the timber finished floor covering as this could lead to potential under performance of the system. Testing Step 4: Once the pipe circuits have been installed and connected to the manifold the system should be pressure tested to 6 bar for a minimum of 1 hour before the timber floor covering is laid. It is recommended that the system remains under pressure whilst the flooring is laid. Tongue & groove flooring Double heat spreader plate Ceiling Polyplumb barrier pipe Polystyrene or foam insulation Supporting joists 21 Finishing Laying a timber floor covering Step 5: Battern systems It is strongly recommended that the timber floor covering is laid immediately after the underfloor heating pipes have been installed and pressure tested to eliminate any risk of damage to the system by other trades. Where it is not possible or desirable to drill or notch the floor joists, Either traditional tongue & groove floorboards or 18mm/22mm chipboard can be fitted directly on top of the spreader plates. These can be fixed directly through the spreader plate down in to the joists below. It is important to indicate the position of pipework in areas where the additional fixing of items such as carpet grip rod or door threshold strips may be fitted at a future date. Used for spans greater than 450mm or less than 350mm. and the floor height can be raised, spreader plates can be used. Fitting insulation with a battern system Step 1: To prevent downward heat transmission, insulate between the voids in the joists with appropriate foam insulation. Fitting the batterns Step 2: Lay 75mm x 25mm battens across the existing joists at 450mm centres. Polypipe does not recommend the application of two layers of timber floor covering as this will severely reduce the heat output of the underfloor heating system. Trim the ends of the batten back to the last joist at alternative ends. Correct application Lay spreader plates between the battens and pin in position. Incorrect application Laying the pipe Fitting the spreader plates Step 3: Step 4: Lay pipe into the spreader plates in accordance with the installation instructions on the previous page, ensuring you follow the testing procedure. Polyplumb barrier pipe Double heat spreader plate 75mm x 25mm battens at 450mm centres If a manufactured timber floor is to be used then it is recommended that this be of a suitable load bearing quality. (Please request advice from the specialist flooring supplier). 22 Joists at spacing greater than 450mm or less than 350mm Pipe only systems The use of heat spreader plates is recommended, as they assist the response time and heat dispersion. However, in some circumstances, simply laying pipe in an air void between foil faced reflective insulation and the underside of the floorboard will be adequate. The space between the top of the insulation and the underside of the floor deck should be kept to a minimum (20mm) and care should be taken to ensure that the insulation is sealed at the edges and ends. Pipe only applications are suitable in areas where the heating response is less important, e.g. bedrooms, and is not recommended in living spaces or over unheated spaces, e.g. rooms above garages. Polyplumb barrier pipe Pipe clip 25mm thick dry mix screed Insulation Tongue and groove flooring Joists Joists at spacing greater than 450mm or less than 350mm Enhancing pipe only systems The effectiveness of pipe only systems can be enhanced by laying a weak (1:6) dry mix screed approximately 25mm thick between the joists. In order to apply this, extra support may be required below the insulation. Although pipe only systems are designed to operate at 60°C flow temperature, the flow temperature may be reduced in these circumstances. Before this system is considered it is suggested you consult a structural engineer to confirm its suitability. 23 MODULAR HEATING PANELS (MHP) A new concept in underfloor heating Modular Heating Panels* are an exciting new product concept from Polypipe that enable quick and simple installation of underfloor heating into suspended floors in both new build and renovation projects. Installing underfloor heating into upper floors can be challenging, even in new build projects. Most conventional underfloor heating systems comprise a single section of pipe, housed or placed within another part of the system structure, such as floor panels, which are cut to size on site. This works fine as there are no interruptions to the laying of the pipe. In suspended floor installations however, the pipe, plates and insulation have to fit within an obvious obstruction: the supporting floor joists. It is working around the joists, and avoiding other services, that has often led to underfloor heating being avoided in upper floors. As the name suggests, a Modular Heating Panel (MHP) is a pre-configured solution, where all of the floor heating system components are supplied fitted within complete panels, which are simply fitted and connected together on site. Thanks to MHP it is now possible to fit panels quickly into the existing joist voids and connect them to a standard heat source. MHP works with both traditional and engineered joists and can be fitted from above or below. *Patent pending. 24 Maximising heat efficiency Due to their high output at relatively low flow temperatures, Modular Heating Panels are ideal for maximising heat efficiency and lowering energy consumption. In most installations it is not necessary to cover the entire floor area. MHP panels work like “underfloor radiators”, applying enough heat to only those areas of the floor that need to be heated and using just enough of them to maintain a suitable room temperature. For a room temperature of 20°C, for example, only 80% floor coverage is required to provide 70W/m2 or around 60% for 50W/m2. This unique product benefit also makes MHP an ideal solution when using heat pumps. The flexibility of panel placement provided by MHP means that floor areas to be covered by items such as built-in wardrobes or baths and shower cubicles can be avoided without detriment to the overall heating provision. Product options MHP is available in 6 panel sizes comprising 2 lengths and 3 widths: MHP available lengths: 1.3m and 2.0m MHP available widths: 330mm, 380mm and 490mm Each MHP panel contains pre-installed pipe circuitry, 30mm of insulation, and is covered in heat diffusing foil. Pipe circuitry is based on 10mm diameter pipe. A 500mm length of pipe extends from each panel allowing connection to the flow and return pipe work from an underfloor heating manifold. MHP panels are easily installed from either above or below and suit the joist widths of both composite ‘I’ beam joists and traditional timber joists. Up to 3 MHP panels can be connected together in series and the recommended maximum room area per circuit is 20m2. Heat diffusion foil 30mm insulation 10mm pipe circuit 25 Designing your layout Designing the ideal room layout for an MHP installation and selecting the required products couldn’t be simpler. Follow the steps below or use the online product selector tool at www.ufch.com or www.freeyourwalls.com. Select panel width Step 1: The spacing of joists and the available gap will determine which MHP panel width will be most suitable for each project. Select the MHP width nearest to the gap width, ensuring that this does not encroach on the space for other services. The 490mm width panel will normally be fitted in the wider joist spacing used by composite joists and ‘I’ beams. Select panel length Step 2: The span of the joists in each room will determine which MHP panel length should be selected. The span is defined as the free space from wall to wall that needs to remain uninterrupted by trimmers or other services. Ideally, install MHP panels prior to other services whenever possible. Use the table below as a quick guide to suitable arrangements of MHP panels leaving a 200mm gap for pipe connections. Arrangement Span 1 x 1.3m Panel 1.4m to 2.2m 1 x 2.0m Panel 2.2m to 2.8m 2 x 1.3m Panels 2.8m to 3.5m 1 x 1.3m Panel + 1 x 2.0m Panel 3.5m to 4.2m 2 x 2.0m Panels 4.2m to 5.0m 26 Planning your room arrangement Step 3: Calculating the amount of floor area to be covered by MHP will be based on the required heat output (see our heat output tables on page 29) and will take into account areas of the floor that do not require heating, such as under built-in wardrobes, baths and shower cubicles. The diagram below illustrates a typical layout that might be considered. 27 Pre-installation requirements Planning Installation from below Before installing MHP panels ensure you have planned out the When installing MHP panels from below you will need to mark positioning of the required panels avoiding all other services such out the positioning of the panels to ensure you have them as electrics, gas and water supply. situated in the correct places for heating the room above. You will not need to do any specific preparation for the Once you have checked the marked out positioning, the MHP installation in a new build property as there will be no ceilings panels can be slotted into place and fixed to the underside or floors in place. of the floor using 1¾” x 8 woodscrews with M6 x 30 dia washers. For existing room refurbishment, you will need to take up your floor if fitting from above or take down the ceiling if fitting from below. Ensure that the area where the MHP panels are to be positioned is free from any debris before commencing installation. It is advisable to use 6 fixings per panel ensuring you avoid the moulded pipe marking on the underside of the panel and fix each panel securely. IMPORTANT NOTE: Polystyrene can cause deterioration to cable insulation when it comes into direct contact with it. Installation Always ensure that electrical cables are not in physical contact with the MHP panels using tape or a polythene strip. Installation from above To install MHP panels from above simply fit support bearers to each side of the joists. These support bearers should be positioned 30mm from the top of the joist and the MHP panel is then simply laid on to these supports. Finishing Once you have connected your system up to the manifold and tested it you can then finish the room by fitting the floor or ceiling in the normal way depending on whether you have installed MHP from above or below. Testing Where possible installations should be tested at 20°C to 18 bar pressure. Any installations once connected to the manifold have a maximum test pressure of 6 bar. 28 Panel layouts 1 Panel layout 2 Panel layout 6 3 1 4 5 2 15mm Polypipe flow and return connections to manifold 1 Part No: PB010 10mm Straight Coupling 2 15mm Polypipe flow and return connections to manifold 3 Part No: PB1115 15mm - 10mm Reduced Branch Tee 4 Part No: PB015 15mm Straight Coupling + Part No: PB1815 15mm - 10mm Socket Reducer 5 6 Part No: PB010 10mm Straight Coupling Part No: PB1115 15mm - 10mm Reduced Branch Tee + Part No: PB1815 15mm - 10mm Socket Reducer Part No: PB1115 15mm - 10mm Reduced Branch Tee + Part No: PB1215 15mm - 10mm Reduced Branch Spigot Tee Product information Heat output Product Code No of panels per pack MHP 490mm (W) x 2.0m (L) MHP49020 5 MHP 490mm (W) x 1.3m (L) MHP49013 MHP 380mm (W) x 2.0m (L) MHP38020 MHP 380mm (W) x 1.3m (L) MHP 330mm (W) x 2.0m (L) MHP 330mm (W) x 1.3m (L) Maximum floor area for flow and return 20m2 Room at 20°C Heat output per panel 5 Flow temp (°C) Av. floor temp (°C) MHP49020 MHP49013 MHP38020 MHP38013 MHP33020 MHP33013 (W) (W) (W) (W) (W) (W) 5 40 25.0 63 42 49 33 42 29 MHP38013 5 45 25.8 75 50 58 39 50 34 MHP33020 5 50 26.6 86 58 67 45 58 39 MHP33013 5 55 28.9 120 80 93 62 80 53 60 30.8 147 99 114 77 98 66 Approximate coverage required: For 70W/m2 room = 80% coverage For 50W/m2 room = 60% coverage Connect up to 3 panels in series Maximum coverage per circuit 20m2 29 TM OVERLAY Underfloor heating that fits over existing floors Overlay™ is a registered trademark of Polypipe Ltd. Overlay™ patent no GB2388181. 30 Overlay is a unique low profile floor heating system ideal for both renovation and new build projects. TM Installed over the existing floor and only 18mm in depth, Overlay™ allows underfloor heating to be installed where traditional underfloor systems would either require expensive excavation or would require the floor to be raised to an unacceptable level. The Overlay™ system is available in 2 panel types to allow for installation to all build types and floor coverings. Overlay™ floor panel is a fibrous panel used for heavyweight floor coverings such as ceramics, or where the floor covering needs to be secured directly to the panel, e.g. solid wood. Overlay™ Lite is a high compressive strength, lightweight insulated panel used for lightweight floor coverings, e.g. laminate, engineered wood and carpet. Due to its ease of handling and cutting it is also more suitable for larger areas and multiple room installations. Overlay™ systems use a 12mm pipe at 150mm pipe centres and provide excellent response times and heat output compared with traditional built in underfloor heating solutions and are therefore ideal for both traditional heating systems and low temperature renewable systems. 31 End return Suitable for: tiles, hard wood, carpet or vinyl** Cover board 12mm pipe circuit 18mm floor panel 600mm x 800mm Overlay™ floor panel TM Overlay Fits over concrete or floorboards Choosing your Overlay™ floor panel Floor finish Cover detail* Ceramic tiles Overlay™ accommodates all types of project and floor coverings and the only choice, is that of which panel will be most appropriate for the installation. Both Overlay™ and Overlay™ Lite can be used for the majority of projects, however the choice of Overlay™ is determined by floor covering selection. Overlay™ and Overlay™ Lite can be used as appropriate in the same project. The more structural nature of Overlay™ however makes it ideal for direct tiling or application of floor finishes which need to be fixed or screwed to the panel. 32 OverlayTM Direct Flexible grout and adhesive Optional cover layer 10mm Ply / 6mm MDF Fix ply using OverlayTM glue plus screw where necessary Optional cover layer 6mm Hardie backer board Use tile adhesive conforming with EN12004-Type C Solid wood, engineered wood & laminate Direct Secret fixing to OverlayTM floor panel through T&G Carpet - with cover layer 10mm Ply / 6mm MDF Fix ply using OverlayTM glue plus screw where necessary 6mm Hardie backer board Use tile adhesive conforming with EN12004-Type C 10mm Ply / 10mm MDF Fix ply using OverlayTM glue plus screw where necessary or Vinyl** - with cover layer * Fixing method Cover board thickness indicated are minimum. The maximum thickness of any cover board is 18mm. Sheet products other than those shown may also be suitable. ** If using Karndean or Amtico type flooring, refer to manufacturers for suitable floor finish. End return Engineered wood, laminate or carpet Cover board Heat diffusion foil 12mm pipe circuit 18mm floor panel 600mm x 1244mm Overlay™ Lite floor panel TM Overlay Lite Fits over concrete or floorboards Overlay™ Lite is the ideal solution for laminate and engineered wood floors which should be laid directly over the system. Overlay™ Lite products are easy to install making it ideal for larger floor areas. Floor finish OverlayTM Lite Cover detail* Engineered wood Laminate Carpet - with cover layer * Fixing method Direct Direct 10mm Ply / 6mm MDF Glue with contact adhesive Key design and installation information Maximum heat output Approx. 100W/m2 Recommended design flow temp 45° to 50°C Maximum circuit length 80m Maximum coverage per circuit 12m2 Material requirements (approx) Overlay™ floor panel Coverage 0.48m2 Overlay™ Lite floor panel Coverage 0.75m2 Pipe 7m length/m2 End returns 1 return bend per floor panel 12mm x 80m coil of pipe 1 coil per circuit 15mm x 12mm adaptors & stiffeners 1 pack per circuit Cover board thickness indicated are minimum. The maximum thickness of any cover board is 18mm. Sheet products other than those shown may also be suitable. 33 Pre-installation requirements Planning Example of ‘squaring off’ an irregular room plan Planning the Overlay™ system beforehand will save time during installation and minimise product waste. The direction the pipe runs to and from the ZRU or manifold and use of the return bends will be the main considerations. The end returns have a flat panel which forms a channel to allow the routing of pipes to multiple circuits in the room. This can be removed where necessary. Floor areas which don’t require pipe circuitry, e.g. beneath kitchen cupboards or sanitary ware, can be ‘blanked’ using 18mm plywood or chipboard. This will make better use of the Overlay™ products. This can also be used to ‘square off’ rooms with irregular walls. Example of ‘blanking’ on kitchen plan Room layouts The following diagrams show some examples of room shapes, pipe requirements and interruptions (pillars, hearths, etc.) which need to be accommodated. Room with 2 circuits End return with panel removed Example of ‘blanking’ in a bathroom End return Room with pillars/hearth End return with panel removed End return 34 Pipe layouts in multiple room installations Multiple room installations require several circuits and careful planning is required close to the manifold to allow for all pipes to be accommodated. 1 Wherever possible pipes can simply go through, rather than round, walls to eliminate the number of pipes requiring access through the entrance of the manifold cupboard. 2 Alternatively leave voids at the edge of the panels. 3 Using return bends as routers or 4 using supply pipes to heat corridors are all ways of managing the installation in this area. 1 2 4 3 35 Overlay™ for heavyweight floor coverings Installation Laying end returns Step 1: Start by fixing two end returns to the floor in a corner of the room. Laying the panels Step 2: Clean down the edges of the panel and apply a 3mm bead of adhesive to the top edge. Then lay it, ensuring you line up the grooves in the panel with those in the end returns. Continue to lay the first row of panels gluing each joint to achieve a secure installation. Remove the pipe panel if not required as per your floor plan. This should be done by using suitable screws in the screw holes of the end return panels when fixing to a wood floor, or by using Overlay™ adhesive (code PB777) to bond the end returns to solid floors. Return bends with pipe plate removed First panel Room wall Return bends with pipe plate remaining First row Subsequent row When gluing the ends, ensure there is no residual glue in the pipe grooves and use short lengths of pipe to help with panel alignment. 36 Step 3: When you get close to end of the first row fit two end returns against the wall as in step 1 and if necessary cut an Overlay™ floor panel to fit and complete the first row. Cutting the panels Laying the pipe Step 5: Starting from your manifold position and allowing enough pipe for connections lay the pipe into the grooves of the Overlay™ floor panel in accordance with your plan. Panels can be cut using a hand saw or jigsaw set at a low speed. Cutting these panels will generate dust so should either be done outside or in a ventilated room. Ensure you wear a particle mask. Finishing Step 4: Once you have completed the first row begin the process again, gluing the ends and sides of each panel, staggering the panels in the second row in a brickwork pattern and continue until the room is complete. Using a floor filler/grout fill any gaps and voids, and fill around any pipework. Tiles can be laid directly on to the Overlay™ floor panels or a cover board can be fitted prior to tiling. When tiling directly over Overlay™ floor panels, use a sealant with flexible adhesive and grout. If fitting solid wood floors they can be discretely screwed through the tongue and groove directly into the Overlay™ floor panel, avoiding pipe circuitry, to minimise movement in the floor covering. Example showing 10mm plywood cover 37 Overlay™ Lite for lightweight floor coverings Laying the panels Step 2: Installation Lay the panel ensuring you line up the grooves in the panel with Laying end returns using short lengths of pipe to help with panel alignment. those in the end returns, then continue to lay the first row of panels Step 1: Start by fixing two end returns to the floor in a corner of the room. Remove the pipe panel if not required as per your floor plan. This should be done by using suitable screws in the screw holes of the end return panels when fixing to a wood floor or by using Overlay™ adhesive (code PB777) to bond the end returns to solid floors. Return bends with pipe plate removed Step 3: When you get close to end of the first row fit two end returns against the wall as in step 1 and if necessary cut an Overlay™ Lite floor panel to fit and complete the first row. First panel Cutting the panels Room wall Panels can be cut using a sharp knife and a metal rule. Return bends with pipe plate remaining First row 38 Subsequent row Step 4: Laying the pipe Once you have completed the first row begin the process again with Step 7: the second row, staggering the panels in a brickwork pattern. Starting from your manifold position and, allowing enough pipe for connections, lay the pipe into the grooves of the Overlay™ Lite floor panel in accordance with your plan. Step 5: Use the self adhesive foil tape along the long panel joints to securely fix the panels to the adjacent row. Step 8: Once you have finished laying the pipe use the self adhesive foil tape to secure the panels and pipe, running across all the panel joints, and do the same across the joints where the panels meet the end returns. Step 6: Now continue this process, completing the whole room. Finishing Laminate and engineered wood can be laid directly over Overlay™ Lite floor panels. Where carpet is being fitted, first fix a 6mm MDF or 10mm plywood using a contact adhesive, then continue to lay the floor covering as normal. It is advisable to mark out pipe positioning to avoid stapling pipes when fitting carpets. 39 CONNECTING TO HEAT SOURCE Polypipe Underfloor Heating Systems are designed to be connected to a variety of heat source options. Gas and oil boilers Heat pumps When connecting to any heat source it is essential that the underfloor heating manifold(s) are fed directly from the heat source with a dedicated set of flow and return primaries, to enable total independent hydraulic control of the underfloor heating system. Under no circumstances should this primary feed be connected into any other heating pipework, such as radiator or domestic hot water primary circuits. Polypipe Underfloor Heating Systems are ideal for use with heat pump systems due to the lower operating temperatures that are produced by this type of heat source. However, to provide temperature limitation protection and sufficient system flow rate for the underfloor heating installation, it is recommended to fit the manual blending valve and pump pack as supplied by Polypipe Building Products Ltd. To provide independent hydraulic control of the entire system, it is important that the installation is designed as an ‘S Plan’ or ‘S Plan Plus’ configuration which allows for a two port zone valve to be fitted to all primary circuits and at each underfloor heating manifold (see diagram). It is the responsibility of the system design/installer to ensure that the heating circulation pump supplied with the heat pump, and any associated primary pipework, is capable of providing sufficient duty to meet the demand up to the underfloor heating manifold assembly. This also applies if a ‘buffer tank’ has been fitted to the heat pump installation. IMPORTANT NOTE: Under no circumstances should a Polypipe Underfloor Heating System be connected in to a ‘Y Plan’ (flow share) system as this will result in serious system operating problems. To ensure that the correct operating temperatures and system flow rates are maintained for the underfloor heating system, the manifold(s) should be fitted with a manual blending valve and circulating pump (see section ‘Water temperature controls’). However, it is the responsibility of the designer/installer to ensure that the boiler and system pump are capable of providing sufficient outputs in order to meet the requirements of the primary pipework, the underfloor heating system and any other equipment installed in the system. Typical ‘S Plan Plus’ configuration A buffer tank or thermal store is often fitted between the heat pump and the underfloor heating system. This is to provide a sufficient quantity of stored water to feed the underfloor heating system and to ensure that the heat pump flow rates are maintained, thereby reducing the risk of cycling. By using a buffer tank installation there is no need to use ‘open circuits’ at the underfloor heating manifold, therefore allowing individual room control. The Underfloor Heating Manufacturers Association (UHMA) do not recommended that the underfloor heating system be used as an ‘open circuit’, to provide the flow rate requirement for the heat pump installation, as this could lead to problems with system control at a later date. For further information regarding the installation of the system please contact the Polypipe Technical Hotline on 01709 770000. Solid fuel and wood burners Typical ‘S Plan Plus’ configuration via thermal store Under no circumstances should a Polypipe Underfloor Heating System be connected directly to this type of heat source. Instead, the burner should be used to provide indirect heat via a thermal store or similar neutraliser. The low temperature feed from this store can then be pumped to the underfloor heating manifold, as with a heat pump installation. Please seek specialist advice from the heat source supplier or manufacturer before commencing the installation. 40 MANIFOLDS Manifolds are common to all systems above 30m2, independent of the underfloor heating system. Manifolds are supplied complete and fixed to the wall mounting bracket. The manifold comes complete with a drain and air vent assembly, which can be positioned on either end of the manifold. Isolation valves are supplied separately for the supply end of each manifold. The bottom manifold is the flow and the top manifold is the return. Each manifold port comes complete with a Polyplumb push fit connection. Pipes are connected to manifolds by inserting a pipe stiffener into the pipe and simply push fitting the pipe into the port. The flow meter on each flow port of the manifold provides a visual indication of the flow through each circuit. Both manual and lockshield balancing can be undertaken by either using the blue cap on the return manifold for manual adjustment, or removing the blue cap and adjusting using the key supplied with each manifold. 62 80 50 L Preparing and installing the manifold Outlets L (mm) 2 190 3 245 4 300 5 355 6 410 7 465 Remove the manifold from the box and arrange the flow and return manifolds to ensure that the inlets/outlets are pointing downwards. Remove the air vent and drain valve from the packaging and connect to the desired end of the manifold. Outlets L (mm) 9 575 10 630 11 685 12 740 13 795 14 850 Dimension A (mm) B (mm) C (mm) Ensure the seal is correctly in place before tightening the compression nut by hand on to the manifold. To ensure the valves are securely connected to the manifold, use a 38mm spanner or wrench to tighten by a further half turn. 8 520 1” 39 64 86 A Remove the isolating valves (supplied separately) from the packaging and connect to the opposite end of the manifold. As with the air vent and drain valve, ensure the seal is correctly in place before tightening the compression nut by hand on to the manifold. Then, complete the connection by using a 38mm spanner or wrench to tighten by a further half turn. Fix the manifold horizontally in the desired position utilising both screw holes on each bracket. B C The manifold is now in position and ready to be connected to the mains from the boiler and the underfloor heating pipe circuits. A set of self adhesive stickers are included to help identify each circuit on the manifold. The stickers also provide the opportunity to record the number of turns required for the correct flow rate through each circuit (for further information on testing and commissioning see pages 52 and 53). 41 WATER TEMPERATURE CONTROLS The temperature of water required in underfloor heating systems is less than that required for radiators or stored hot water. If these other services are connected to the same boiler it will be necessary to control the water temperature using one of the Polypipe water temperature control units. Pre assembled UFH control packs Alpha UFH control pack (PB970020) Modulating pump version Compact UFH control pack (PB970016) Standard pump version These pump units control water temperatures between 30°C and 60°C. The inclusion of these pump units ensure that the flow to the underfloor heating circuits is automatically adjusted to allow for the opening and closing of actuators when individual room temperature is required. The unit is suitable for manifolds demanding up to 15kW heat load. The thermostatic mixing control is factory set to provide 45°C mixed water to the heating manifold. The mixed water flow temperature can be adjusted and locked very simply to suit the design flow temperature within the range of 30-60°C. These pump units are fitted directly to the manifold at either end by turning the pump through 180°. An additional zone valve is required when using an Alpha pump unit supplied by other manufacturers. 42 Site assembled UFH control pack (PB970015) Underfloor heating control pack (PB970015) The pack controls water temperatures between 35°C and 60°C, and incorporates a fixed head pump and a 22mm 2-port zone valve, which is suitable for manifolds demanding up to 15kW heat load. The set temperature of the water is shown on the wheel head. Manifold bends (PB12735) The water temperature control packs can be fitted at 90° to the manifold using the manifold bends. This allows manifolds and pump units to be corner mounted where space is at a premium, e.g. in an understairs cupboard. The control pack is fitted directly to the manifold at either end, as both left hand and right hand connector bends are supplied with the unit. Dimensions of assembled unit 155mm 110mm 50mm 30mm Manifold bend installed with underfloor heating control pack can also be used with Alpha UFH control pack. 130mm 40mm NOTE: The valves shown on this diagram are purchased separately and not supplied with the unit. 43 ROOM TEMPERATURE CONTROLS A comprehensive range of Polypipe room temperature controls are available to compliment Polypipe Underfloor Heating Systems, designed to maximise comfort and efficiency of the system, whilst providing ease of use to occupants. They provide perfect control solution for underfloor heating systems and are available in both Wired and Radio Frequency (RF) options. Controlling underfloor heating Whilst regulations permit all of our control systems to be used with any of our floor types we would recommend that some control systems are more appropriate than others due to floor type, use of space, type of project, and the user or occupant. All our control systems allow individual room temperature control as a minimum with our programmable controls providing independent time and temperature control of each room. Time and temperature control of each room (Programmable Room Thermostats) This control method uses programmable room thermostats and allows each room to be individually programmed ensuring that rooms are heated to the level required, when required. Each room can be programmed differently for each day of the week ensuring that rooms are only heated when occupied. This option is available in both Wired and RF ranges. This control method also provides “setback” and “optimum start” functions: UÊ Ê-iÌL>VÊqÊ/ ÃÊiÃÕÀiÃÊÌ >ÌÊÜ iÊÌ iÊÀÊÃÊÕVVÕ«i`]Ê a minimum temperature level is pre set by the user. This is important when using high mass systems such as the Polypipe solid floor system. The response time of the system is slower than that of other Polypipe systems and we therefore recommend that this method be used to ensure that rooms are heated to an appropriate level when required UÊ Ê"«ÌÕÊÃÌ>ÀÌÊqÊ/ ÃÊvÕVÌÊ>ÜÃÊÌ iÊÌ iÀÃÌ>ÌÊÌÊ learn the heat up profile of each room individually. This allows the user to set a “warm by” time rather than an on time ensuring that the room is always to temperature by the time required 44 Temperature control of each room (Time Clocks and Room Thermostats) This method allows the user to set the on/off time for all rooms served by a single manifold and provides individual room temperature control. This option is most suited for low mass systems that have a quicker response e.g. OverlayTM, where setback is not required. The room temperature control can either be provided by means of a Digital Display Thermostat (Digi stat) or traditional Dial type stat. All options are available in both Wired and RF ranges. Room temperature control operation In all cases the control setup will consist of room thermostats, a master wiring centre, slave units (for multiple room control) a zone valve and actuators. In essence the operation is the same where the room demand is sensed by the room thermostat. This then opens an actuator on each circuit of pipe supplying the room and also opens the zone valve serving the manifold. When the zone valve is open the underfloor pump is activated and a 230V or Volt free signal is sent to the boiler for firing. Schematic switching diagram - relays not shown Room thermostat room 1 demand Room thermostat room 2 satisfied Boiler on Zone valve open UFH Pump on Actuator room 1 open Actuator room 2 closed Circuit room 1 open Circuit room 2 closed Building regulations requirements UÊ ÊÊÃ}iÊÃÌÀiÞÊ«iÊ«>Ê`Üi}ÃÊÜ iÀiÊÌ iÊÛ}Ê>Ài>ÊÃÊ In order to comply with the room temperature control UÊ Ê-iÌL>VÊ«À}À>>Li®ÊVÌÀÃÊ>ÀiÊÀiVi`i`ÊÜ iÀiÊÃ`Ê greater than 70% of the total area, individual room controls are not required requirements for domestic buildings under the Buildings floors are thicker than 65mm* Regulations (Part L). The following should be adhered to * Although the recommended thickness of Polypipe solid floor system is 65mm we recommend that programmable stats are used on this floor type. as a minimum. NOTE: this applies to installations connected to both domestic gas boilers and heat pumps UÊ Ê>V ÊÀÊà Õ`ÊLiÊ«ÀÛ`i`ÊÜÌ ÊÌÃÊÜÊÌ iÀÃÌ>ÌÊÀÊ programmable thermostat. Where 2 rooms have a similar function e.g. kitchen and utility room It may be possible to use one thermostat to control both rooms Polypipe room temperature controls selection All control options provide temperature control to each room as required, a summary of the options is shown below. Control type Time control Per room Display / operation Per manifold Digital Programmable Wired Thermostats ✓ ✓ Programmable RF Thermostats ✓ ✓ Dial Connectivity Wired Wireless RF ✓ ✓ Digital Wired Thermostats ✓ ✓ Digital RF Thermostats ✓ ✓ Dial Wired Thermostats ✓ ✓ Dial RF Thermostats ✓ ✓ ✓ ✓ ✓ ✓ 45 Control equipment - Room Thermostats Dial Room Thermostat (PBRS) and RF version (PBRS RF) Programmable Room Thermostats (PBPRP) This thermostat is used in conjunction with the time clock and RF version (PBPRPS RF) (PB2CTC or PB4CTC RF). All are provided with a wet room The programmable room thermostats offer sensor connection. This traditional dial type room thermostat combines accurate comfort control with a familiar dial type user operation. the following outstanding features: UÊ ÇÊ`>ÞÊ«À}À>} UÊ -iÌL>VÊ>`Ê«ÌÕÊÃÌ>ÀÌ UÊ ÀÃÌÊ«ÀÌiVÌ UÊ `>ÞÊÃÌ>`LÞÊ`i UÊ Ê«ÀiÊÃiÌÊ«À}À>ÃÊvÀÊi>ÃÞÊ«À}À>} UÊ -«iÊÕÃiÀÊ`iwi`Ê«À}À>} UÊ Wet room sensor connection Time Clocks – 2 Zone Clock (PB2CTC) and 4 Zone Clock RF (PB4CTC RF) The digital time clocks are used in conjunction with digital and dial thermostats. The time clocks offer the following features: UÊ ÇÊ`>ÞÊ«À}À>} UÊ ÓÊâiÊÓÊ>v`®ÊVÌÀÊÊÌ iÊÜÀi`ÊÛiÀÃÊ*Ó / ® UÊ {ÊâiÊ{Ê>v`®ÊVÌÀÊÊÌ iÊ,Ê*{ / Ê,®ÊÛiÀÃÊ UÊ ÀÃÌÊ«ÀÌiVÌ UÊ `>ÞÊÃÌ>`LÞÊ`i Digital Room Thermostats (PBDIG) UÊ Ê«ÀiÊÃiÌÊ«À}À>ÃÊvÀÊi>ÃÞÊ«À}À>} and RF version (PBDIG RF) UÊ -«iÊÕÃiÀÊ`iwi`Ê«À}À>} The digital room thermostat provides simple temperature UÊ ÝÌiÀ>ÊvÀÃÌÊÃÌ>Ì®ÊViVÌ control with a large easy to read digital display. Used in conjunction with the time clock (PB2CTC or PB4CTC RF) they provide stylish and accurate room control. All are provided with a wet room sensor connection. 46 Wiring centres Ancillary items Single Zone Master Unit (PB1ZM) Wet Room Sensors (PB23020) and RF version (PB2ZM RF) Where temperature control needs to be provided to a bathroom or other wet area, this sensor is installed in the wet area and connected to any of the room thermostats which can be installed in an adjacent dry area. The sensor is supplied with 3m of cable which can be extended to a maximum of 10m providing NTC 10k cable is used. The sensor can be removed from the housing and used as a floor sensor where sensitive floor coverings are used. The master wiring centres enable simple wiring and switching of all common components in the system. For multiple zone systems this is used in conjunction with the slave units. Neon indicators show the status of the connections. These wiring centres allow connection of: UÊ i>Ì}Ê>ÊÃÕ««Þ]Ê1Ê«Õ«]ÊâiÊÛ>ÛiÊ>`ÊVVÊ UÊ Ì ÊÓÎä6Ê>`ÊÛÌÊvÀiiÊLiÀÊÃÜÌV }ÊViVÌ UÊ Ê iVÌÊvÀÊ>ÊÃ}iÊÀÊÌ iÀÃÌ>ÌÊÜÀi`ÊÛiÀî and 2 room thermostats in the RF version Single RF Receiver (PBREC RF) The receiver accepts a signal from any RF Thermostat or clock and allows RF clocks and RF stats to be used with wired master or slave units. UÊ *Õ}ÊÊViVÌÛÌÞÊÌÊÌ iÊÃ>ÛiÊÕÌÃÊvÀÊÕÌ«iÊâiÊVÌÀÊ Slave Units - 4 Zone Slave (PB4ZS and 6 Zone Slave PB6ZS) and 4 Zone RF version (PB4ZS RF) These units are always used in conjunction with the master unit and provide simple wiring of actuators and room thermostats for multiple zone control. Neon indicators show room activation. 47 Wiring centres - for wired controls Single Zone Master (PB1ZM): When used in a ‘single zone’ application the master wiring centre (PB1ZM) provides the wiring connections for the underfloor heating pump, two-port zone valve, boiler switched live connection (230V or volt free) and the programmable room thermostat. Wiring details for Single Zone Master Unit (PB1ZM) RF Room Stat Options PBPRPS RF PBDIG RF PBRS RF Hard Wired Room Stat Options PBPRP PBDIG PBRS Remove Link if Time Clock Fitted 230v Supply L L N E E E N L OR RF Clock PB4CTC RF N NC End Switch 2 Port Zone Valve RF Receiver 230v Supply L N Note: Only use this connection when using a Single Room Thermostat. If using Slave do NOT use. Power Supply L N C 1 Remove Link if Zone Valve Fitted Clock C 1 RF Receiver OR Volt Free Contact Boiler L 230v S/L Connection Boiler UFH Pump Time Clock Not fitted when using programmable stats 4 & 6 Zone Slave Unit (PB4ZS and PB6ZS): Where multiple room control is required the master wiring centre should be used in conjunction with the 4 or 6 zone slave units PB4ZS or PB6ZS. The slave units provide wiring connections for the programmable room thermostats and the manifold 2-wire actuators. Up to 4 actuators can be connected per zone. The 4 and 6 zone slave units (PB4ZS & PB6ZS), must be used in conjunction with the Single Zone Master (PB1ZM). The slave unit simply plugs into the master unit to provide additional connections for the required number of control zones. Wiring details for 4 & 6 Zone Slave Unit (PB4ZS and PB6ZS) Hard Wired Room Stat Options PBPRP PBDIG PBRS RF Room Stat Options PBPRPS RF PBDIG RF PBRS RF RF Receiver OR 230v Supply 2 Wire Actuators PB00401, Max 4 per zone 48 1 Zone shown only Repeat for further Zones Must be used with Master Unit Wiring centres - for RF controls 2 Zone Master Unit RF (PB2ZM RF): The PB2ZM RF master unit provides electrical connections for the UFH pump, motorised valve, actuators, boiler and up to 2 control zones. Wiring details for 2 Zone Master Unit RF (PB2ZM RF) PB4CTCRF Four Channel RF Time Clock (if using PBDIG RF or PBRS RF type room thermostats) Remove Link if Time Clock Fitted Room Thermostat Options PBDIG RF PBRS RF Max 2 PBPRPS RF Remove Link if Zone Valve Fitted OK L L N E 230VAC Power Supply PB2CTC 2 Channel Hard Wired Time Clock option N E 2 Port Zone Valve 1 2 3 4 Pump Zone 1 (if using PBDIG RF or PBRS RF type room thermostats) 230V AC Boiler Connection 1 2 3 4 L N E 2 Wire Actuators PB00401, Max 4 per zone Zone 2 For further zones use the PB4ZS RF Volt Free Boiler Connection 4 Zone Slave Unit RF (PB4ZS RF): Where more than 2 zones of control are required, the PB4ZS RF is used with the PB2ZM RF master unit above to provide up to 4 additional control zones. The unit provides wiring for up to 4 actuators per zone and 4 built in zone receivers. OK Wiring details for 4 Zone Slave Unit RF (PB4ZS RF) Room Thermostat Options PBPRPS RF PBDIG RF Max 4 PBRS RF 2 Wire Actuators PB00401, Max 4 per zone 1 Zone shown only Repeat for further Zones Must be used with Master Unit 49 SINGLE ROOM APPLICATIONS All Polypipe Underfloor Heating Systems can be installed in single rooms and connected to the existing wet heating system. In rooms greater than 30m2 it is recommended that the connection to the underfloor heating system is made via a manifold and installed in the same way as a multiple room installation with single area control. Connections to the existing wet heating system Areas of up to 30m2 should use the Polypipe Zonal Regulation Unit (ZRU) as this provides a simpler method of connecting into the existing system, without the need for expensive hydraulic or electrical alterations. A small number of boilers can be affected hydraulically by the use of a second pump in the system. 200mm Thermostatic blending valve Pipe thermostat 260mm Pump The pipe work connections to the ZRU are for 15mm diameter pipe and the ZRU should not be connected to the system from any pipe smaller than 15mm. NOTE: Check with the boiler manufacturer to ensure compatibility with the ZRU. The preferred connection to the ZRU is to the main flow and return pipe work of a 2 pipe system, i.e typically from 22mm distribution pipe work. However it can also be connected to the nearest existing radiator. Pipe connection to operate underfloor heating at the same time as the boiler Connection from main distribution pipe work Pump speed control Heating return Tees and spigot elbows for second circuit if required Heating flow Underfloor heating flow Underfloor heating return The ZRU simply connects to the existing heating system providing: UÊ 7>ÌiÀÊÌi«iÀ>ÌÕÀiÊVÌÀÊÎäc ÊÌÊÈäc ® for the underfloor heating UÊ / iÊVÀÀiVÌÊyÜÊÀ>ÌiÊvÀÊÌ iÊÕ`iÀyÀÊ i>Ì} UÊ ÕÌ>ÌV>ÞÊÃÜÌV iÃÊÊ>`ÊvvÊÛ>Ê>ÊLÕÌ pipe thermostat UÊ ÊÜÀ}ÊViVÌÊvÀÊ>ÊÀÊÌ iÀÃÌ>Ì or wireless sensor UÊ >ÊLiÊViVÌi`ÊÌÊ«iÀ>ÌiÊÌ iÊÕ`iÀyÀÊ i>Ìi` room independently with the existing system Connection from nearest radiator The diagram above shows the ZRU connected to operate with the boiler on / off firing. Due to the quick response of low mass systems (Overlay™, Overlay™ Lite, MHP, etc) this is likely to be suitable. Using this method for solid floor installations may require the timings of the existing heating to be altered to allow the underfloor heating system to reach comfort temperature. If the room is to be controlled independently of the existing central heating system, a zone valve needs to be installed between the boiler and the ZRU. Pipe connection to operate ZRU / underfloor heating independently Programmable room thermostat Zone valve to underfloor heating Zone valve to radiator, etc 50 Connection from main distribution pipe work The pipe supplying the ZRU should be connected to the main boiler distribution pipe prior to the connection of other zone valves. A programmable room thermostat can be used to operate the zone valve and, in turn, the end switch within the zone valve can provide a signal to fire the boiler. Filling the underfloor heating system Use the heating system to fill the underfloor heating circuits and ZRU. Blanking off the ZRU Installation of ZRU Step 1: The ZRU can be positioned either in the room where the underfloor heating is installed or in an adjacent area, 300mm from the finished floor level to allow for pipe connections. Remove the underfloor heating return pipe from ZRU and blank off the ZRU underfloor heating return port with a short pipe with a blank end or a blanking plug. Filling the ZRU Fitting the ZRU Step 2: Step 1: Allow open ended underfloor heating return pipe to drain into a bucket or hose. Screw unit to wall. Connecting the ZRU Step 3: Step 2: Connect heating pipe work via an isolation valve (as shown). Open the flow isolation valve to the ZRU. Step 4: Step 3: Connect underfloor heating circuit(s) using an isolation valve. Use tees and spigot elbows to form connections for 2 and 3 circuit systems. Step 4: When uninterrupted flow is seen from the underfloor heating return pipe, close the isolation valve and re-connect the underfloor heating return pipe to the ZRU. Step 5: Open all the valves. Connect mains wiring (as diagram below) via a fused spur. Step 6: Vent the ZRU through the air vent and pump vent. Wiring details IMPORTANT NOTE: If in any doubt you should contact a qualified electrician. The water temperature must be 45°C to operate the unit. Wiring diagram Room stat (example) - not supplied Blank off underfloor heating return to ZRU Open underfloor heating flow isolation valve Vent underfloor heating system from underfloor heating return pipe Remove link if using a room thermostat PRODUCT SELECTOR Room packs for UFCH & OVERLAY™ A range of room packs containing all flooring and ZRU are available Type Solid Floor Overlay™ Overlay™ Lite Area 12m2 (So12Z) 12m2 (O12Z) 12m2 (OL12Z) 20m (So20Z) 20m (O20Z) 20m2 (OL20Z) 30m2 (So30Z) 30m2 (O30Z) 30m2 (OL30Z) 2 Pump 2 A 5m2 Overlay™ Bathroom Pack (O5B) is controlled with a temperature limiting valve rather than the ZRU Boiler feed thermostat Mains 42°C close (Fused spur) 31°C open 3amp 51 SYSTEM COMMISSIONING Once installed, Polypipe Underfloor Heating Systems should be tested thoroughly to ensure they are working effectively, including initial filling of the system and system balancing. If you require any further information please contact the Polypipe Technical Team on 01709 770000. Initial system filling Flow adjusting valve 1 System balancing Once the system is up and running it is necessary to balance the system in accordance with the design data provided. This should be done using the following method: Ensure that the boiler and main system duty pump are operating correctly and that sufficient heat input and flow rates are being provided at the manifold(s). 4 Set the underfloor heating controls to call for heat and check to see that the two-port zone valve and manifold pump are energised. 2 Manifold flow meter 3 Close the manifold isolating valves (1) & (2). Connect a hosepipe to manifold return drain off point (4) and take to a drain. Connect a second hose pipe to the manifold filling point (3) and attach to mains cold water supply (3 bar max). The connections to the manifold drain and fill points are ¾” BSP. Use flexible ¾” tap connectors for the simplest method of connection. Close all of the flow adjusting valves on the return manifold rail by turning the blue caps in a clockwise direction. Open all of the manifold flow meters on the manifold flow rail by turning them in an anti-clockwise direction using a radiator vent key. Open the first circuit on the manifold by turning the blue cap anti-clockwise and then open the drain and fill points (4) & (3). Using the mains cold water supply flush out and fill the first circuit. Once this circuit is running clear and free from air, open the second circuit on the manifold and repeat the process until all of the circuits are fully opened and purged of air. Close the drain and fill points. IMPORTANT NOTE: All of the manifold flow meters must be fully opened prior to flushing and filling the manifold circuits. 52 Remove the blue cap from the manifold flow port and, using the bleed key provided, turn the flow adjustment spindle clockwise to completely close the circuit. NOTE: The isolating valve fitted to the manifold flow meter is not used for balancing purposes. If it becomes necessary to close off a manifold completely, this can be done by using a ¾” brass cap with a suitable rubber washer insert. Once all of the circuit flow rates have been adjusted the system should be left to operate for a short period whilst any remaining air is removed. Once this has been done the flow rates should be re-checked and adjusted if necessary before the actuator heads are fitted. If the actuator heads are not likely to be fitted for a while then it is recommended that the blue caps are used in order to protect the flow rate settings and prevent any debris from entering the flow valve assembly. Slowly open the valve by turning the spindle anti-clockwise until the required flow rate in l/min is achieved in the flow meter window. When adjusting the manifold flow rates care should be taken to ensure that the adjustment spindle is not left with any of the thread showing. In order to carry out any maintenance to the installation it is possible to isolate individual circuits by closing both the flow and return ports, as shown in the diagram below. IMPORTANT NOTE: When using the PB970014 Modulating Pump Unit, ensure that the primary boiler flow temperature provided at the manifold is at least 15°C hotter than the required manifold operating temperature. This is due to the fact that this manifold uses an ‘injector method’ to mix down the primary water. Furthermore, when balancing the system with this particular manifold kit please ensure that the modulating pump is set to a fixed head speed whilst making any adjustments. 53 TECHNICAL DATA Heat output tables Overlay™ and Overlay™ Lite The tables below show typical performance data for the various Polypipe Underfloor Heating Systems. Solid floor Mean water temperature °C Pipe spacing mm Output W/m2 Surface floor temperature °C Pipe spacing mm 40 150 150 68.0 26.3 79.0 28.1 55 150 101.0 30.1 60 150 124.0 32.0 25.7 45 100 76.2 27.0 50 100 91.6 28.3 55 100 95.0 28.6 40 200 50.8 24.9 45 200 63.6 26.0 50 200 76.3 27.0 55 200 77.0 27.2 40 300* 42.8 24.2 45 300* 53.6 25.1 Mean water temperature °C Pipe spacing mm 50 300* 64.3 26.0 40 90 55 300* 66.7 26.9 40 225/300 Output W/m2 31.7 Surface floor temperature °C 23.1 45 225/300 40.2 23.9 50 225/300 49.2 24.7 55 225/300 50.0 24.8 60 225/300 52.3 25.0 25.8 150 60.9 Pipe spacing mm 61.0 Surface floor temperature °C 45 100 Mean water temperature °C Output W/m2 50 40 Suspended and floating floor 54 Mean water temperature °C Modular Heating Panels (MHP) Output W/m2 52.0 Surface floor temperature °C 25.0 45 90 64.0 26.0 50 90 76.0 27.0 55 90 100.0 29.0 60 90 124.0 31.0 TECHNICAL DATA General system information Maintenance Many of the components within Polypipe Underfloor Heating Systems are drawn from our well established Polyplumb system of pipes and plumbing fittings. Polyplumb is suitable for use in hot and cold water supply and both radiator and underfloor heating systems. Polypipe polybutylene pipe provides flexibility and freedom when designing pipe layouts, whilst Polyplumb push fit fittings are fast to install and secure in use. Polypipe systems require no maintenance, other than checks on the inhibitor level in heating systems. Strength The Polyplumb system is suitable for use in working applications up to 12 bar / 20°C (6 bar / 90°C). Pipes are suitable for bending to a radius of 12 x diameter when unsupported or 8 x diameter when supported. Connections and fittings are tested to BS 7291: Class S for thermal cycling test, long term pressure tests, rapid pressure test and pull-out strength. System malfunction temperature Polyplumb pipes and fittings are tested to BS 7291: Parts 1 and 2, which incorporates a pressurised thermal cycling test and a test regime at temperatures of 114°C and 3.5 bar pressure for 1,000 cycles at a duration of 30 minutes per cycle. See British Standards website for further details. Gases The Polyplumb pipe system is not suitable for the transportation of gases. Standard Polypipe polybutylene pipe is oxygen permeable and is only suitable for all domestic water and heating installations. Polypipe recommends that corrosion inhibitors are introduced to, and maintained in, all heating systems, whether they use standard or barrier pipe. Due to the long pipe runs used in underfloor heating systems, we recommend barrier pipe is used throughout to minimise the potential for oxygen ingress into the system. Light Polyplumb pipe and fittings should be protected from UV light. Standard decorating paints form adequate protection. Polyplumb pipe insulation forms adequate protection for external use. All Polypipe polybutylene pipe is delivered in light-protective packaging. Thermal The co-efficient of thermal expansion of Polypipe polybutylene pipe is 1.3 x 10-4m/mºC. It accommodates expansion by its modulus of elasticity. Water The polybutylene material used in Polyplumb pipes and fittings is WRC / WRAS approved. It is resistant to the build-up of scale. Short term chlorination for disinfection of supply pipe work and normal levels of chlorine in UK domestic water supplies will not have an adverse effect on the integrity of the pipe. Polypipe pipe is not suitable, however, for systems that carry a high concentration of chlorine, for example supplies to swimming pools. Acoustic The flexibility of Polypipe polybutylene pipe provides better acoustic performance than rigid pipe systems in terms of low noise transmission and low water hammer effect. Electrical As Polypipe polybutylene pipe does not conduct electricity, installations generally require less equipotential bonding than metal systems. Both the IEE and the IoP give guidance on the earth bonding requirements of plastic pipe systems. Where Polypipe polybutylene pipe breaks the continuity of existing metal pipe, which may be used for earthing or bonding, this continuity should be reinstated by affixing permanent earth clips and a section of earth cable between the ends of the copper pipe. Side-effects Polypipe believes there to be no side-effects from handling or using its pipes and fittings. Compatibility Polypipe polybutylene pipe connects to rigid pipe systems and is compatible with all recommended inhibitors. For details of compatibility with specific building materials, such as filler foam and wood worm treatments, please consult the Polypipe Technical Hotline on 01709 770000. Polypipe pipes and fittings can be painted using emulsion or undercoat and gloss. Cellulose based paints, strippers or thinners must not be used. Durability Polypipe Underfloor Heating products, excluding manifolds and control products, are guaranteed for 50 years against defects in materials or manufacture from the date of purchase (exclusions apply). Visit www.ufch.com or www.freeyourwalls.com to a view a full copy of our current guarantee(s). 55 FAULT FINDING CHARTS Hydraulic fault finding chart Before using this flow chart please ensure that both the primary and underfloor heating systems are full and that all isolating valves are fully open. Please also ensure that the room thermostats are calling for heat. YES Boiler fault NO Electrical fault (see electrical fault finding guide) START Is the boiler firing and the primary pump operating? NO Check for 230V signal to boiler from master wiring centre NO Check if the underfloor heating zone valve is open YES Is there hot water present prior to underfloor heating mixing valve? YES Primary flow and return crossed or debris in mixing valve NO YES Is hot water passing through underfloor heating manifold? NO Check 230V signal to zone valve from master wiring centre YES Zone valve fault Check temperature adjustment on underfloor heating mixing valve NO Electrical fault (see electrical fault finding guide) YES YES Is there a visible flow present through all underfloor heating circuits? NO YES Fault finding complete 56 NO Check 230V signal to pump from master wiring centre YES Pump fault Check if the actuators are open NO Check 230V signal to actuator from slave unit NO Electrical fault (see electrical fault finding YES Actuator fault YES YES Is the system performing correctly? Underfloor heating pump operating NO Ensure that manifold lockshield valves are fully open Adjust pump speed and set flow rates in accordance with the system design data as provided Electrical fault finding chart (master connecting box) This testing procedure should only be carried out by fully qualified persons. Testing should be done with all switches on and room thermostats calling. Is the fused spur switched on? START NO Turn the fused spur on NO Replace 3A fuse in spur NO Replace fuse on PCB (2.5A 230 Vac Type 5x20) NO Faulty PCB replace unit NO Faulty room thermostat replace unit NO Relay 1 faulty replace PCB NO Relay 2 faulty replace PCB YES System operating correctly YES Is there 230V at ‘L’ terminal on PCB? YES Is Green Power LED illuminated? YES Is 230V present on all T2 terminals? YES Is 230V present on all T1 terminals? YES Are the zone valve and underfloor heating pump operating? YES Is there 230V to NC Boiler switch live connection? (Check operation of Volt free relay connections if using 24V) YES Check boiler connection NO Is the boiler firing? 57 Accreditations, standards and guarantees One of Europe’s largest manufacturers of plastic plumbing and heating products, Polypipe Building Products Ltd has developed a unique range of underfloor heating solutions. Designed for installation in to both existing and new build projects all Polypipe products are manufactured and tested to the highest standards to ensure maximum quality and performance. For further quality assurance all Polypipe products carry the following Standards and System Approvals: Manufacturing quality assurance FM00318 In accordance with BS ES ISO 9001:2000 (BSI registered firm Certificate FM00318). Installation standard British Gas - has accepted the Polypipe Polyplumb Class S Polybutylene pipe system as being acceptable for open vented and sealed central heating systems and is eligible for acceptance onto Three Star Central Heating System Cover. P.B.P.S.A. Polypipe Building Products Ltd is a member of the Polybutylene Piping Systems Association, which is a recognised association of the companies whose aim is to promote the features, benefits and best practice installation techniques of polybutylene pipe systems, as well as providing a wide range of technical information and support. Polypipe is a member of the Underfloor Heating Manufacturers Association. Guarantee To follow the recommendations of BS5955 - Part 8 2001 Plastic Pipework (Thermoplastic Materials). British standard Class S Rated to BS7291 Part 1 and Kitemark Licence Number 38148 to BS7291 Part 2. WRAS Listed in the WRAS Water Fittings and Materials Directory. KIWA/KOMO Certificate numbers K14341, 14342 and 14343. BBA Polypipe polybutylene barrier pipe, fittings, accessories and Underfloor Heating Systems are covered by BBA Certificate No. 00/3699. 58 Polypipe Underfloor Heating products, excluding manifolds and control products, are covered by a 50 year Guarantee*, which protects against defects in materials or manufacture of the heating system from date of purchase. This guarantee only applies if the system is installed in accordance with the manufacturer’s recommendations, and is used in a normal domestic operation. This document should be read in conjunction with all other documentation supplied with Polypipe products. If you have any queries, please contact our Technical Hotline on 01709 770000. UNDERFLOOR HEATING SYSTEMS DESIGN ENQUIRY FORM CLIENT DETAILS Project: (Polypipe use only) Project Reference No: Contact: Client: Address: Telephone: Post Code: Mobile: SENDERS DETAILS Client: Contact: Address: Post Code: Telephone: Designs to be returned to Client Mobile: Sender UNDERFLOOR HEATING REQUIREMENTS Floor Type (Solid, Suspended, Floating, MHP, Overlay™, Overlay™ Lite) Manifold Position(s) (Please also indicate on drawing) Ground Floor 1st Floor 2nd Floor NOTES CONSTRUCTION DETAILS If NOT to current Building Regulations U Value (W/m2 deg C) External Walls Roof Windows Please return your completed form to: Underfloor Heating Design, Polypipe Building Products Ltd, 1 Neale Road, Doncaster, DN2 4PG, England Tel: 01709 770000 Fax: 01709 770001 www.ufch.com 59 Technical Installation Guide Underfloor Heating Systems Polypipe Building Products Broomhouse Lane Edlington Doncaster DN12 1ES Tel: 01709 770 000 Fax: 01709 770 001 2410 London Road Mount Vernon Glasgow G32 8XZ Tel: 0141 778 8822 Fax: 0141 778 2703 Dromore Road Lurgan, Craigavon Co. Armagh BT66 7HL Tel: 028 38 881270 Fax: 028 38 882344 www.polypipe.com Polypipe Underfloor Heating Systems trade website: www.ufch.com Polypipe Underfloor Heating Systems consumer website: www.freeyourwalls.com