109493-01 Owner`s Manual - FMI Customer Care Center
Transcription
109493-01 Owner`s Manual - FMI Customer Care Center
42" and 50" Wood Burning Masonry Fireplace OWNER’S OPERATION AND INSTALLATION MANUAL PFS C (V)G42/50 Smooth Face with Insulation (V)G42R/50R Smooth Face with Insulation and Bottom Door Rail (V)G42H/50H Smooth Face with Insulation and Herringbone Refractory (V)G42HR/50HR Smooth Face with Insulation, Bottom Door Rail and Herringbone Refractory ® US ICC-ES #ESR-2542 SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or accessory items when needed. Keep it with your other important papers. This fireplace is approved for use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21.60 or Z21.84 standards or for use with a vent-free gas log heater approved to ANS Z21.11.2 standard. This wood burning fireplace complies with UL127-CAN/ULSS610-M87 standard as a FACTORY BUILT APPLIANCE. FOR CANADA: The authority having jurisdiction (such as the municipal building department, fire department, etc.) should be contacted before installation to determine the need to obtain a permit. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. For more information, visit www.fmiproducts.com Table of Contents Safety Information................................................ 2 Specifications....................................................... 3 Fireplace Installation............................................ 5 Venting Installation............................................... 7 Optional Gas Line Installation.............................11 Glass Door Installation....................................... 12 Operation and Maintenance Guidelines............. 13 Technical Service............................................... 14 Replacement Parts............................................. 15 Accessories........................................................ 16 Safety WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury, property damage or loss of life. Refer to this manual for assistance or additional information. Consult a qualified installer or local distributor. IMPORTANT: Check local codes before installing this fireplace. Before beginning the installation of the fireplace, read these instructions through completely. • This FMI PRODUCTS, LLC fireplace and its components are safe when installed according to this installation manual. Unless you use FMI PRODUCTS, LLC components, which have been designed and tested for the fireplace system, you may cause a fire hazard. • The FMI PRODUCTS, LLC warranty will be voided by and FMI PRODUCTS, LLC disclaims any responsibility for the following actions. a. Modification of the fireplace, components, doors, air inlet system and damper control. b. Use of any component part not manufactured or approved by FMI PRODUCTS, LLC in combination with a FMI PRODUCTS, LLC fireplace system. Proper installation is the most important step in ensuring safe and continuous operation of the fireplace. Consult the local building codes as to the particular requirements concerned with the installation of all factory built fireplaces. WARNING: Do not install a fireplace insert in this firebox unless the manufacturer's instructions with the insert specifically state this fireplace has been tested for use with the insert. 2 This fireplace is not intended to be used as a substitute for a furnace to heat an entire home. Use for supplemental heat only. FOR YOUR SAFETY • Do not store or use gasoline or any other flammable vapors or liquids in the vicinity of this or any other appliance. • Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. • Do not place clothing or other flammable materials on or near the appliance. • Never leave children unattended when a fire is burning in the fireplace. WARNING: Use solid wood or processed solid fuel firelogs only. When processed wood fuel fire logs are used, do not poke or stir the logs while they are burning. Use only fire logs that have been evaluated for the application in fireplace and refer to fire log warnings and caution markings on packaging prior to use. WARNING: Always leave glass doors fully opened or fully closed when operating fireplace. www.fmiproducts.com 109493-01R Specifications 42" Models ROUND TOP TERMINATION SQUARE CHASE-TOP TERMINATION 2" CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIAL NO COMBUSTIBLE MATERIAL ON FACE COMBUSTIBLE WALL BOARD 11/2" AIR SPACE BACK AND SIDES OUTSIDE AIR MINIMUM 18" TO PERPENDICULAR SIDEWALL GAS LINE KNOCKOUTS HEARTH EXTENSION 66" X 20" 0" TO BOTTOM 12" EACH SIDE 12" 30.5" 11" 67" 21.25" 58" 49" 30" 28.5" 0.625" 51" 42" 8" 1" 51" AIR KIT KNOCK OUT LEFT SIDE 24.25" GAS LINE KNOCK OUTS 3.5" 23.5" 9.5" 10.5" 8.5" 13" 17" 41.25" 109493-01R www.fmiproducts.com 3 Specifications 50" Models ROUND TOP TERMINATION SQUARE CHASE-TOP TERMINATION 2" CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIAL NO COMBUSTIBLE MATERIAL ON FACE COMBUSTIBLE WALL BOARD 11/2" AIR SPACE BACK AND SIDES OUTSIDE AIR MINIMUM 18" TO PERPENDICULAR SIDEWALL GAS LINE KNOCKOUTS 0" TO BOTTOM 12" EACH SIDE HEARTH EXTENSION 74" X 20" 12" 38.5" 11" 67" 21.25" 58" 49" 30" 28.5" 0.625" 59" 50" 8" 1" 59" LEFT SIDE 32.75" AIR KIT KNOCK OUT GAS LINE KNOCK OUTS 3.5" 23.5" 10.5" 9.5" 8.5" 13" 17" 50" 4 www.fmiproducts.com 109493-01R Fireplace Installation Selecting location To determine the safest and most efficient location for the fireplace, you must take into consideration the following guidelines: 1. The location must allow for proper clearances (see Figures 1 and 2). 2. Consider a location where the fireplace will not be affected by drafts, air conditioning ducts, windows or doors. 3. A location that avoids the cutting of joists or roof rafters will make installation easier. 4. An outside air kit is available with this fireplace (see Optional Outside Air Kit, page 6). 3. 4. 5. Minimum clearance to combustibles Back and sides of fireplace 1 1/2" min.* Front of fireplace 48" min. Floor** 0" min. Perpendicular wall to opening12" min. Top spacers 0" min. Mantel clearance see Mantels, page 5 Chimney outer pipe surface 2" min. 6. upon a metal or wood panel extending the full width and depth of the fireplace. Set the fireplace directly in front of this opening and slide unit back until nailing flanges touch side framing. Check the level of fireplace and shim with sheet metal if necessary. Before securing fireplace to prepared framing, the ember protector (provided) must be placed between hearth extension (not supplied) and under bottom front edge of fireplace to protect against glowing embers falling through. If the fireplace is to be installed on a raised platform, a Z-type ember protector (not supplied) must be fabricated to fit your required platform height. The ember protector should extend under the fireplace a minimum of 1 1/2". The ember protector should be made of galvanized sheet metal (28 gauge minimum to prevent corrosion. Using screws or nails, secure the fireplace to the framing through flanges located on the sides of the fireplace. * Not required at nailing flanges ** See step 2 of Framing WARNING: Do not pack required air spaces with insulation or other materials. Minimum/Maximum Chimney Height The minimum height of the chimney, measured from the base of the fireplace to the flue gas outlet of the termination, is 16 feet for straight flue or a flue with one elbow set. The maximum distance between elbows is 6 feet. For systems with two elbow sets, the minimum height is 22 feet. The maximum height of any system is 50 feet. This measurement includes the fireplace, chimney sections and the height of the termination assembly at the level of the flue gas outlet (see Figure 15, page 9). 67.125" 58.125" 51.25" (42") 59" (50") 1. Frame opening for fireplace using the dimensions shown in Figures 1 and 2. 2. If fireplace is to be installed directly on carpeting, tile (other than ceramic) or any combustible material other than wood flooring, the fireplace must be installed 109493-01R Maintain 1 1/2" Clearance at Sides and Back of Fireplace 65" (42" Models) 71" (50" Models) Framing 30.125" 1 1/2" Clearance Not Required at Nailing Flanges 92" (42" Models) 100" (50" Models) Figure 2 - Corner Installation www.fmiproducts.com 5 Fireplace Installation Hearth Extension A hearth extension projecting a minimum of 20" in front of and a minimum of 12" beyond each side of the fireplace opening is required to protect combustible floor construction in front of the fireplace. Fabricate a hearth extension using a material which meets the following specifications: a layer of noncombustible, inorganic material having a thermal conductivity of K=0.84 BTU IN/FT, HR. F (or less) at 1" thick. For example, if the material selected has a K factor of 0.25, such as glass fiber, the following formula would apply: 0.25 x 1.0" = 0.30" thickness required 0.84 Thermal conductivity "K" of materials can be obtained from the manufacturer or supplier of the noncombustible material. If the hearth extension is to be covered, use noncombustible material such as tile, slate, brick, concrete, metal, glass, marble, stone, etc. Provide a means to prevent the hearth extension from shifting and seal gap between the fireplace frame and hearth extension with a noncombustible material (see Figure 3). WARNING: Hearth extension is to be installed only as shown in Figure 3. Fireplace Front Mantels A mantel may be installed if desired (see Figure 4). Woodwork such as wood trims, mantels or any other combustible material projecting from the front face must not be placed within 12" of the fireplace opening. Combustible materials above 12" and projecting more than 1 1/2" from the fireplace must not be placed less than 15" from the top opening of the fireplace (NFPA STD 211, Sec. 7-3.3.3). Mantels or any other combustible material also may come up to the side edge of the black metal face of the fireplace just as long as the projection from the front face fall within the limit shown in Figure 4. 6" Ref. 3" Nom. 12" Min. Upper Section of Fireplace Fireplace Opening Top View of Fireplace FIREBOX Hearth Extension 7.75" Seal Gap SAFE ZONE 33° Ember Protector Figure 3 - Hearth Extension 6 11/2" Max. 15" Min. Seal Gap Fireplace Front Raised Hearth Fireplace Front Elevated Safe Zone for Projection of Combustible Materials 33° Ember Protector Ember Protector Combustible Material 12 1/4" Ref. 3" Max. 4.5" Min. to Perpendicular Side Wall 12" Combustible Material Must Not Overlap Front Face Figure 4 - Mantel Clearances to Combustible Material www.fmiproducts.com 109493-01R Venting Installation Optional Outside air Kit (Model ak4/ak4f) The installation of an outside air kit should be performed during the rough framing of the fireplace due to the nature of it's location. Outside combustion air is accessed through a vented crawl space (AK4F) or through a sidewall (AK4). CAUTION: Combustion air inlet ducts shall not terminate in attic space. Secure to Collars with Metal Tape, Screws or Straps (Min. 1/4" x 20" size) Air Inlet Location Must Allow For Bushes or Snow LINEAL GAIN DESCRIPTION GAIN Georgian Fireplace 66 1/2" 12-12DM Pipe Section 10 5/8" 12-12HT 18-12DM Pipe Section 16 5/8" 18-12HT 24-12DM Pipe Section 23 5/8" 24-12HT 36-12DM Pipe Section 34 5/8" 36-12HT 48-12DM Pipe Section 46 5/8" 48-12HT RLT-12D Round Termination 7 3/4"* RLT-12HT Square Chase-Top STL-12D 7" to 15"* with Slip Section * The lineal gain for the terminations is measured to the flue gas outlet height. 15" Galvanized Outer Pipe Air Inlet Eyebrow Vent Hood Vented Crawl Space Required for (Check Local Codes Wall Installation Before Installing in a Vented Crawl Space) Figure 5 - Outside Air Kit Chimney Pipe The FMI PRODUCTS, LLC chimney system consists of 12", 18", 24", 36" and 48" snaplock, double-wall pipe segments, planned for maximum adaptability to individual site requirements. Actual lengths gained after fitting overlaps must be taken into consideration (lineal gain) and are given in the lineal gain chart (see Figure 6). Lineal Gain is the actual measurable length of a part after two or more parts are connected. For Canada, use chimney parts designated "HT". WARNING: The opening in the collar around the chimney at the top of the fireplace must not be obstructed. Never use blown insulation to fill the chimney enclosure. 109493-01R PART NO. 12 3/8" Stainless Inner Pipe Hemmed End Figure 6 - Lineal Gain Assembly and installation of double wall chimney system Each double wall chimney section consists of a galvanized outer pipe, a stainless steel inner flue pipe and a wire spacer. Pipe sections must be assembled independently as chimney is installed. When connecting chimney directly to fireplace, the inner flue pipe section must be installed first with lanced side up. The outer pipe section can then be installed over the flue pipe section with hemmed end up. Press down on each pipe section until lances securely engage hem on fireplace starter. The wire will assure the proper spacing between inner and outer pipe sections. Continue to assemble chimney sections as outlined above, making sure that both inner and outer pipe sections are locked together. When installing double wall snap-lock chimney together, it is important to assure the joint between chimney sections is locked. Check by pulling chimney upward after locking. The chimney will not come apart if properly locked. It is not necessary to add screws to keep the chimney together (exception, see Figure 9, page 9). www.fmiproducts.com 7 Venting Installation Continued Using ELBOW offsets (30E-12DM) 1. To achieve desired offset, you may install combinations of 12", 18", 24", 36" and 48" length of double wall pipe (see offset chart and Figure 7). OFFSET A RISE B 12" CHIMNEY LENGTH 18" 24" 36" 48" 2. Chimney weight above offset rests on return elbow. Straps must be securely nailed to rafters or joists (see Figure 8, details a and b). 3. Maximum length of pipe between supports (return elbow or 12S-12DM) is 6' of angle run. Maximum of two 6' angle run sections per chimney system (see Figure 7). 4. All pipe connections between the offset and return must be secured with two screws on the outer pipe only (see Figure 9, page 9). Do not penetrate the inner stainless. See Detail A 4 3/8" 16 3/8" ELBOW SET ONLY 9 3/4" 25 1/2" 1 12 3/4" 30 3/4" 1 15" 34 3/4" 1 18" 40" 1 1 21 1/4" 46 1/4" 1 23 3/4" 49 1/4" 1 1 27 3/4" 56 3/4" 1 2" Min. 30" 60 3/4" 1 1 33" 66" 1 1 36" 71" 1 1 38 1/4" 75" 2 Straps 41 1/4" 80 1/4" 1 1 1 Straps 45" 86 3/4" 2 Detail B See Detail B 3 1 46 /4" 89 /2" 1 1 1 Angle Firestop 51" 97" 1 1 53 1/4" 101" 1 2 56 1/4" 106 1/4" 2 59 1/4" 111 1/2" 1 1 1 Straps 61 3/4" 115 1/2" 1 2 Straps 64 3/4" 120 3/4" 1 2 68 1/4" 127" 2 1 Detail A 70" 130" 1 1 2 Return Elbow 74 1/4" 137 1/2" 1 2 1 Figure 8 - Ceiling Support Pipe 76 3/4" 141 1/2" 1 2 1 12S-12DM 79 3/4" 146 3/4" 4 OFFSET CHART (22-50 FT. SYSTEM HEIGHT) Return Elbow Offset Elbow Return Elbow Offset Elbow 6' Max. Return Elbow 6' Max. Ceiling Support Pipe 12S-12DM Return Elbow 6' Max. Offset Elbow A Offset Elbow Return Elbow Offset 6' Max. Elbow B 6' Max. 6' Max. C Figure 7 - Typical Offset Terminations 8 www.fmiproducts.com 109493-01R Venting Installation Continued Penetrating roof Screws B A Figure 9 - Elbow Offset Firestop Spacers (FS-10) Firestop spacers are required at each point where the chimney penetrates a floor space. Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials. When the pipe passes through a framed opening into a living space above, the firestop must be placed onto ceiling from below as shown in Figure 10. They also provide complete separation from one floor space to another or attic space as required by most codes. When the double wall pipe passes through a framed opening into an attic space, the firestop must be placed into an attic floor as shown in Figure 11. To maintain a 1" clearance to pipe on a roof with a pitch, a rectangular opening must be cut. 1. Determine the center point through which pipe will penetrate roof. 2. Determine the center point of the roof. Pitch is the distance the roof drops over a given span, usually 12". A 6/12 pitch means that the roof drops 6" for each 12" one measure horizontally down from the roof rafters. 3. Use the roof opening chart (Figure 12) to determine the correct opening length and flashing required. 4. Remove shingles around the opening measured. Cut out this section. 5. Add next sections of pipe until the end penetrates roof line. Check to see that the proper clearances are maintained. Extend chimney by adding sections of double wall pipe until pipe is minimum of 30" above the highest point of the roof cutout. Termination and chimney must extend a minimum of 36" above the highest point where it passes through the roof. 19.5" Min. 30" Min. 2" Min. 2" Min. Existing Ceiling Frame 2" Min. Firestop Spacer Screws or Staples (Min. of 8) Figure 10 - Firestop Spacer with Living Space Above Ceiling Firestop Spacer Screws or Staples (Min. of 8) Existing Ceiling Frame Figure 11 - Firestop Spacer with Attic Space Above Ceiling 109493-01R Opening "A" Pitch Slope Opening Used Flashing "A" Max. Model No. Flat 0° 19.5" V6F-10DM 0-6/12 26.6° 22" V6F-10DM 6/12- 12/12 45.0° 27" V12F-10DM Figure 12 - Roof Opening Measurements Flashing installation (v6f-10dm or v12f-10dm) Determine flashing to be used with the roof opening chart. Slide flashing over pipe until base is flat against roof. Replace as many shingles as needed to cover exposed area and flashing base. Secure in position by nailing through shingles (see Figure 13, page 10). DO NOT NAIL THROUGH FLASHING CONE. www.fmiproducts.com 9 Venting Installation Continued Storm Collar Flashing Cone Nail Only Outer Perimeter of Flashing Overlap Shingles Top and Sides Only CAUTION: Do not seal openings on the rooftop flashing. Follow the installation instructions provided with the termination being used. RTL-10D Stainless Inner Flue Pipe Underlap Shingles at Bottom Figure 13 - Flashing Installation Installing Flashing on a Metal Roof When installing the flashing on a metal roof, it is required that putty tape be used between the flashing and the roof. The flashing must be secured to the roof using #8 x 3/4" screws and then sealed with roof coating to prevent leakage through the screw holes. A roof coating must also be applied around the perimeter of the flashing to provide a proper seal. Storm Collar Installation (SC2-1) Place storm collar over pipe and slide down until it is snug against the open edge of the flashing (see Figure 14). Apply waterproof caulk around the perimeter of the collar to provide a proper seal. Chimney Pipe Storm Collar Secure Termination to Outer Pipe with 3 Screws Level of Flue Gas Outlet Waterproof Caulking Storm Collar Flashing Overlap Underlap Shingles (Top and Sides Shingles of Flashing Base) Figure 15 - Termination Chase installations Instructions for chase installations are included with the chase style termination chosen. In a multiple chase installation, be sure to provide adequate distance between terminations to prevent smoke spillage from Waterproof one termination to another. Terminations be separated a minimum of 24" center to center Caulk and stacked at a minimum vertical height difference of 18" (see Figure 16). Flashing Note: If a decorative shroud is to be installed, contact the manufacturer for specifications. Figure 14 - Storm Collar Terminations/Spark Arrestor The fireplace system must be terminated with the listed round top or chase terminations. In any case, refer to the installation instructions supplied with the termination. 18" Min. Typ. 24" Min. 24" Min. Figure 16 - Multiple Chase Installation 10 www.fmiproducts.com 109493-01R Venting Installation Continued 10 foot rule All flue gas outlet chimney terminations must extend a minimum of 3 feet in height above the highest point where it passes through the roof and must be at least 2 feet above the highest point of the roof that is within a horizontal distance of 10 feet (see Figure 17). Level of Flue Gas Outlet 10' 10' 2' Min. 3' Min. 2' Min. Finishing fireplace Combustible materials, such as wallboard, gypsum board, sheet rock, drywall, plywood, etc. may make direct contact with sides and top around the fireplace face. It is important that combustible materials do not overlap the face itself. Brick, glass, tile or other noncombustible materials may overlap the front face provided they do not obstruct essential openings like louvered slots or any other opening. When overlapping with a noncombustible facing material, use only noncombustible mortar or adhesive. 3' Min. Figure 17 - 10 Foot Rule Optional Gas Line Installation Gas line hook up should be done by your supplier or a qualified service person. Note: Before you proceed, make sure your gas supply is turned off. Use only a 1/2" black iron pipe and appropriate fittings. 1. Remove knockout indentation on refractory or firebrick wall located above refractory hearth floor. The knockout indentation must be firmly tapped with any solid object such as a 1/2" dowel until it is released. Remove fragmented portions of refractory (see Figure 18). 2. Remove gas line cover plate located on either side of fireplace and pull out insulation from gas line conduit sleeve. Save insulation for reuse. Replace screws. 3. Run a 1/2" black iron gas line into fireplace through the rear at gas line conduit sleeve (if using a raised platform, add height). Provide sufficient gas line into fireplace chamber for fitting connection (see Figure 19). Note: Secure incoming gas line to wood framing to provide rigidity for threaded end. 4. Repack insulation around gas line and into sleeve opening. Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace cement, Install the gas appliance or cap off gas line if desired. 109493-01R Outside of Fireplace Gas Line Conduit Insulation Side Firebrick Finished Side Remove Knockout 1/2" Dowel Gas Conduit Cover Refractory Knockout Plug Figure 18 - Gas Line Knockout Outside of Fireplace Gas Line Conduit Incoming 1/2" Black Iron Pipe Side Firebrick Finished Side Seal Opening Repack with Insulation Refractory Cement Provide Enough Threaded End for Fitting Connection Figure 19 - Gas Line Installation www.fmiproducts.com 11 Optional Gas Line Installation Continued CAUTION: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply soap and water solution to all connections and joints. Bubbles forming show a leak. Correct all leaks at once. DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPERATE ANY APPLIANCE IF A LEAK IS DETECTED. LEAK TESTING SHOULD BE DONE BY A QUALIFIED SERVICE PERSON. WARNING: Do not operate an unvented gas log set in this fireplace with the chimney removed. If you install a decorative gas appliance (vented gas log), the decorative gas appliance must comply with the Standard for Decorative Gas Appliance for Installation in Solid Fuel Burning Fireplaces, ANS Z21.60 or Z21.84 and shall also be installed in accordance with the National Fuel Gas Code, ANSI 7223NFPA 54 latest edition. WARNING: If the fireplace has been used for wood burning, the firebox and chimney must be cleaned of soot, creosote and ashes by a qualified chimney cleaner. Creosote will ignite if heavily heated. WARNING: When using a decorative vented gas log, the damper must be removed or permanently locked in the fully open position and the glass doors must be in the fully open position. Glass Door Installation IMPORTANT: Install glass door frame before installing glass door. Installing Door Frames 1. Remove screws from smoke shelf (see Figure 20). 2. Mount top door frame and secure with screws removed in step 1. Top Door Frame Smoke Shelf 3. Remove center brick by pulling ring handle (see Figure 21). 4. Remove ash box. 5. Remove three screws located at front of firebox (see Figure 21). 6. Align bottom rail mounting holes with holes at front of firebox and secure with screws removed in step 5. 7. Place ash box in place. Replace center brick. Bottom Door Rail Ash Box Center Brick Screws Ring Handle Figure 21 - Installing Bottom Door Frame Figure 20 - Installing Top Door Frame 12 www.fmiproducts.com 109493-01R Glass Door Installation Continued Installing glass doors Spring clips have been installed but some adjustments may be needed. If doors do not close properly or do not appear straight, see Door Adjustment. 1. With bi-fold doors completely folded, insert bottom pivot pin into pivot hole located near bottom corner of front face opening and swing door to vertical position making sure top pins slide into door Fold Door and Slide Top Pins Into Track Spring Clip Insert Pin into Spring Clip track. Door is installed when top door pin snaps into spring clip. 2. Repeat step 1 for remaining door. If you find doors do not close properly or do not appear level or straight, proceed with section on door adjustment, Door Adjustment Remove doors and slightly loosen lower pivot clips and upper spring clips. Replace doors and fully close them. Use 1/8" shims (any material) to level doors. Once proper setting is achieved, carefully open doors enough so that you can access spring clips with a Phillips screwdriver. Tighten screws. See Figure 23. Spring Clip Insert Bottom Pivot Pin into Hole Pivot Hole Figure 22 - Installing Bi-Fold Doors Figure 23 - Adjusting Bi-Fold Doors Operation and Maintenance Guidelines Glass Doors Glass doors are optional with the fireplace. When fireplace is in operation, doors must be fully opened or fully closed position only or a fire hazard may be created (see Figure 24). A fireplace equipped with glass doors operates much differently than a fireplace with an open front. A fireplace with glass doors has a limited amount of air for combustion. Excessive heat within the fireplace can result if too large a fire is built or if combustion air gate is not completely open. The following tips should be followed to assure that both the fireplace and glass door retain their beauty and function properly. Both the flue damper and glass doors must be fully opened before starting fire. This will provide sufficient combustion air and maintain safe temperatures in firebox. IMPORTANT: The glass must be allowed to warm slowly and evenly. The tempered glass will withstand a gradual temperature rise to 550° F, which is more than a normal fire will generate. Such materials as pitch/wax laden logs, very dry mill end lumber and large amounts of paper or cardboard boxes can create an excessively hot fire and should not be burned in this fireplace. Always keep the fire well back from the doors and never allow flames to contact the glass. Doors Fully Closed Fireplace Front Fireplace Front Doors Fully Opened Figure 24 - Bi-Fold Glass Doors 109493-01R www.fmiproducts.com 13 Operation and maintenance Guidelines Continued WARNING: Fireplaces equipped with glass doors should be operated only with doors fully opened or doors fully closed. Doors, if left partly open, may draw gas and flame out of the fireplace opening creating risks of both fire and smoke. Cleaning Glass Clean glass with any commercial glass cleaner or soap and water. Do not use any abrasive material to clean glass. Do not clean glass with any cool water if glass is still hot from the fire and smoke. A gas line or gas log lighter may be installed for the purpose of installing a vented or ventfree decorative gas appliance incorporating an automatic shutoff device and complying with the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces, ANSI Z21.60 or American Gas Association draft requirements for Gas Fired Log Lighters for Wood Burning Fireplaces, Draft NO. 4 dated August, 1993. If you wish to install an unvented (vent-free) gas log set, only unvented gas log sets which have been found to comply with the standard for unvented room heaters, ANSI Z21.11.2 are to be installed in this fireplace. WARNING: Risk of fire! Replace grate with FMI PRODUCTS, LLC model 109496-01 (42" Models) or 109496-02 (50" Models) grate only. This grate has been designed to keep the operation of your fireplace safe and efficient. Damper Weight To Close Damper Damper Weight Outside air and damper handle operation The damper handle, which opens and closes the damper blade, is located in the upper front face of the fireplace. Pushing the handle forward and up through the keyway slot will free damper blade to automatically open. Pushing the handle forward and down will lock damper blade closed (see Figure 25). The outside air kit lever is located at the left and right hand sides of fireplace (see Figure 26). Lifting lever up will free the outside air door to open. Pulling lever down will lock the door. To Open Damper Figure 25 - Operating Damper Handle Open Position Closed Position Figure 26 - Outside Air Kit Lever 14 www.fmiproducts.com 109493-01R Technical Service You may have further questions about installation, operation, or troubleshooting. If so, contact FMI PRODUCTS, LLC at 1-866-3284537. When calling please have your model and serial numbers of your heater ready. You can also visit FMI PRODUCTS, LLC’s web site at www.fmiproducts.com. Replacement Parts Herringbone Brick Liner Bottom Front Brick Refractory 111509-01 - VG42H Models 111509-02 - G42H Models 111515-01SA - VG50H Models 111515-02SA - G50H Models Bottom Rear Brick Refractory 111510-01 - VG42H Models 111510-02 - G42H Models 111512-01 - VG50H Models 111512-02 - G50H Models Right Brick Refractory 111507-01 - VG50H Models 111507-02 - G50H Models 111526-01 - VG42H Models 111526-02 - G42H Models Left Brick Refractory 111508-01 - VG50H Models 111508-02 - G50H Models 111527-01 - VG42H Models 111527-02 - G42H Models Rear Brick Refractory 111511-01 - VG42H Models 111511-02 - G42H Models 111513-01 - VG50H Models 111513-02 - G50H Models StandarD Brick Liner Bottom Front Brick Refractory 111425-01 - VG42 Models 111425-02 - G42 Models 111430-01 - VG50 Models 111430-02 - G50 Models Bottom Rear Brick Refractory 111426-01 - VG42 Models 111426-02 - G42 Models 111428-01 - VG50 Models 111428-02 - G50 Models Right Brick Refractory 111600-01 - VG42 Models 111600-02 - G42 Models 111423-01 - VG50 Models 111423-02 - G50 Models Left Brick Refractory 111601-01 - VG42 Models 111601-02 - G42 Models 111424-01 - VG50 Models 111424-02 - G50 Models Rear Brick Refractory 111427-01 - VG42 Models 111427-02 - G42 Models 111429-01 - VG50 Models 111429-02 - G50 Models Grate - (V)G50(H) 109496-01 (V)G42(H) 109496-02 Ember Protector - 20093 Ash Box - 111498-01 109493-01R www.fmiproducts.com 15 Accessories Bi-Fold Glass Door BDG42 - 42" Black Finish BDG42B - 42" Brushed Brass Finish BDG42P - 42" Platinum Finish BD50 - 50" Black Finish BD50B - 50" Brushed Brass Finish BD50P - 50" Platinum Finish Double Wall Pipe - 12-12DM, 18-12DM, 24-12DM, 36-12DM, 48-12DM, 12-12HT, 18-12HT, 24-12HT, 36-12HT and 48-12HT Optional Outside Air Kit for Sidewall Installation - AK4 Storm Collar - SC2-1 Firestop Spacer FS-10 Roof Flashing V6F-10DM - 0 to 6/12 Pitch V12F-10DM - 6/12 to 12/12 Pitch 30° Offset and Return SQUARE CHASE-TOP TERMINATION - STL-12D 30E-12DM and 30E-12HT Optional Outside air kit for Round ToP TErminations RLT-12D and RLT-12HT floor installation - ak4f 2701 S. Harbor Blvd. Santa Ana, CA 92704 1-866-328-4537 www.fmiproducts.com 109493-01 Rev. R 09/09