our latest floplast brochure here (pdf 999kb)
Transcription
our latest floplast brochure here (pdf 999kb)
Hi Quality Floplast Rainwater Systems From www.rockwell-meriden.co.uk INSTALLATION 1 Plan your installation using the component diagrams to assist you in selecting the correct type and quantity of products required. ● Fascia Brackets should be spaced at a maximum of one metre apart on straight gutter runs. (800mm in the case of the Niagara system) ● Angles and Stopends should have a Fascia Bracket within 150mm of the fitting. Sales Office Direct Line: ● A supporting Pipe Clip should be used on Shoes, Branches and Bends where necessary. 01676 522224 ● Support downpipes below offset at maximum intervals of 1.8 metres. Fax: 2 Where necessary remove the old gutter and replace old fascia board with FloPlast maintenance free PVC-UE co-extruded Fascia Board. 01676 522985 3 Establish the position of the Running Outlet, usually over an existing drain, and fix securely to fascia board. OUTLET AT END OF GUTTER RUN System 4 Fix a Fascia Bracket 100mm short of furthest point from the Outlet. Allow for a fall to the outlet (1:600 is recommended) using a string line. Gutter Fixed Level Gutter Fixed at 1:600 Fall Gutter Flow (litres/sec) Roof Area M2 Gutter Flow (litres/sec) Roof Area M2 Half Round 0.92 44 1.17 56 Square Line 1.70 82 1.81 88 2.34 112 2.50 122 ● Fascia Brackets should be positioned so as to avoid the fixing screws splitting the top edge of any timber fascia board. All brackets should be secured to the fascia board with two 25mm x 5mm (1” x 10) screws or one 32mm x 6.5mm (11/4“ x 14) screw. 2.05 98 2.87 137 ● Unions should be fixed using a 25mm x 5mm (1” x 10) screw. Hi-Cap 2.60 Square Line Hi-Cap ● Fix Fascia and Union Brackets at required intervals ● Outlets and Angles should be fixed using two 25mm x 5mm (1” x 10) screws. OUTLET AT CENTRE OF GUTTER RUN Half Round 5 Fixings: 132 ● In areas of heavy snowfall it is recommended that each fascia bracket is secured using two 25mm x 5mm (1” x 10 screws). 125 2.75 3.41 160 3.95 190 6.14 294 6.25 300 ● Rainwater downpipe clips should be fixed using two 32mm x 6.5mm (11/4“ x 14) screws. 3.97 190 5.56 266 ● Use round headed screws which should be brass or zinc plated. 6 Lubricate all gutter seals with FloPlast silicone spray lubricant to ensure an easy fit and to allow for movement caused by expansion and contraction. 7 Working from the Running Outlet insert the back edge of the gutter under the retaining lip of the wrap around clip. Using slight downward pressure on the gutter snap the front edge of the retaining clip over the front of the gutter. (Ensure that the marked expansion allowance is kept.) 8 Use a Union Bracket or Angle to join to next gutter length in order to build up a gutter run. Use a Stopend to complete the run. 9 Downpipe installation starts at the outlet. If an offset is required use two Offset Bends with or without a short piece of pipe or soil connector or alternatively use an adjustable offset bend. Ensure a 6mm gap is left at the top of the downpipe for expansion. 10 Pipe Connectors if required should be secured to the wall with a Pipe Clip. 11 At the base of the pipe, fit a Shoe secured with a Pipe Clip or connect downpipe to underground drainage system using a 110mm x 68mm reducer (SP96). BS 4576 FloPlast 112/68mm Round Rainwater System is manufactured to this specification and standard. BS EN ISO 9002:1994 FloPlast Pipes and Gutters are manufactured within a quality management system which has been assessed and registered by the British Standards Institution as meeting the requirements of BS EN ISO 9002: 1994 (certificate no. Q 09318). 0899 112mm GUTTER & FITTINGS 90˚ ANGLE Half Round 112mm/68mm Rainwater System 92.5˚ OFFSET BEND CODE RA1 RK1 FASCIA BRACKET RA1 90° ANGLE ■ The original Half Round profile. ■ Pre-fitted gutter seal retaining clip system for fast user friendly installation. ■ Cost effective solution for both new build and refurbishment applications. ■ Connects to most other metal or plastic systems. 112.5˚ OFFSET BEND CODE RA2 ANGLE - Any degree CODE RA9 ■ A practical, easy to install system. ■ Good flow capacity. CODE RB1 BS4576 135˚ ANGLE HALF ROUND 68mm PIPE & FITTINGS CODE RB2 SHOE CODE RB3 STOPEND - EXTERNAL CODE RE1 RU1 UNION BRACKET RG2/4 GUTTER RO1 RUNNING OUTLET RE1 STOPENDEXTERNAL PIPE CLIP CODE RC1 STOPEND - INTERNAL CODE RE2 HOPPER CODE FASCIA BRACKET CODE RK1 RE1 STOPEND - INTERNAL RUNNING OUTLET CODE RO1 RB2 112.5˚ OFFSET BEND Universal Hopper square & round RHS1 PIPE SOCKET CODE RS1 COLOURS UNION BRACKET CODE RU1 DIMENSIONS (mm) 112 RP2.5/4/5.5 PIPE 112.5˚ BRANCH CODE RY1 GUTTER (112mm) CODE RG4 RG2 68 PIPE CODE RP2.5 RP4 RP5.5 52 RS1 PIPE SOCKET RC1 PIPE CLIP GUTTER ADAPTOR CODE cast iron Ogee R/H cast iron Ogee L/H to half round cast iron RD3 RD4 RD5 UNIVERSAL RISE & FALL RAFTER BRACKET CODE RF1 SPARES/ANCILLARIES CODE Gutter Clip RRC1 Gutter Seal RRS1 400ml Silicone Lubricant SL400 Gutter Guard (5m pack) TOP RAFTER BRACKET CODE RR1 RB3 SHOE 2 metres, 2.5 metres, 4 metres and 5.5 metres. SIDE RAFTER BRACKET CODE RR2 FloPlast recommend the use of lubricant on all gutter seals for ease of fitting and for improved performance. Gutter and pipe code reference numbers refer to length of run: 114mm GUTTER & FITTINGS 65mm PIPE & FITTINGS 92.5˚ OFFSET BEND 90˚ ANGLE CODE RAS1 CODE RBS1 Square Line 114mm/65mm Rainwater System 135˚ ANGLE SQUARE LINE ■ Attractive rectilinear profile. RAS1 90° ANGLE RKS1 FASCIA BRACKET ■ Flow capacity in excess of Half Round. ■ Connects to most other metal or plastic systems. CODE RBS2 ANGLE - Any degree CODE RAS9 ■ Pre-fitted gutter seal retaining clip system for fast user friendly installation. ■ Cost effective solution for both new build and refurbishment applications. 112.5˚ OFFSET BEND CODE RAS2 ADJ. OFFSET BEND CODE RBS5 FloPlast will fabricate any non-standard angle to special order RUS1 UNION BRACKET RGS2/4 GUTTER RES1 STOPEND EXTERNAL STOPEND - EXTERNAL CODE RES1 SHOE CODE RBS3 STOPEND - INTERNAL CODE RES2 ROS1 RUNNING OUTLET RES2 STOPEND - INTERNAL PIPE CLIP CODE RCS1 FASCIA BRACKET RCS2 (Flush) CODE RKS1 COLOURS RUNNING OUTLET HOPPER CODE CODE ROS1 RBS2 112.5° OFFSET BEND DIMENSIONS (mm) 114 65 RCS1 PIPE CLIP STOPEND OUTLET CODE ROS2 60 RPS2.5/4/5.5 PIPE Universal Hopper square & round PIPE SOCKET CODE RSS1 UNION BRACKET CODE RUS1 112.5˚ BRANCH CODE RYS1 SQ/RD GUTTER ADAPTOR CODE RDS1 RSS1 PIPE SOCKET RCS2 FLUSH PIPE CLIP Allows downpipes to be fixed flush to wall. SQ/RD DOWNPIPE ADAPTOR CODE RDS2 GUTTER (114mm) CODE RGS4 RGS2 PIPE CODE RPS2.5 RPS4 RPS5.5 GUTTER ADAPTOR CODE to cast iron ogee R/H to cast iron ogee L/H RDS3 RDS4 SPARES/ANCILLARIES CODE RISE & FALL RAFTER BRACKET RBS5 ADJUSTABLE OFFSET BEND Allows for minimum offset of 25mm up to a maximum of 65mm. RHS1 Gutter Clip RRC1 RF1 Gutter Seal RRS1 (UNIVERSAL) 400ml Silicone Lubricant SL400 Gutter Guard (5m pack) CODE TOP RAFTER BRACKET CODE RR1 RBS3 SHOE SIDE RAFTER BRACKET FloPlast recommend the use of lubricant on all gutter seals for ease of fitting and for improved performance. CODE RR2 Gutter and pipe code reference numbers refer to length of run: 2 metres, 2.5 metres, 4 metres and 5.5 metres.