our latest floplast brochure here (pdf 999kb)

Transcription

our latest floplast brochure here (pdf 999kb)
Hi Quality Floplast Rainwater Systems From
www.rockwell-meriden.co.uk
INSTALLATION
1 Plan your installation using the component diagrams to assist you in selecting the correct type and
quantity of products required.
● Fascia Brackets should be spaced at a maximum of one metre apart on straight gutter runs.
(800mm in the case of the Niagara system)
● Angles and Stopends should have a Fascia Bracket within 150mm of the fitting.
Sales Office Direct Line:
● A supporting Pipe Clip should be used on Shoes, Branches and Bends where necessary.
01676 522224
● Support downpipes below offset at maximum intervals of 1.8 metres.
Fax:
2 Where necessary remove the old gutter and replace old fascia board with FloPlast maintenance free
PVC-UE co-extruded Fascia Board.
01676 522985
3 Establish the position of the Running Outlet, usually over an existing
drain, and fix securely to fascia board.
OUTLET AT END OF GUTTER RUN
System
4 Fix a Fascia Bracket 100mm short of furthest point from the Outlet.
Allow for a fall to the outlet (1:600 is recommended) using a string line.
Gutter Fixed Level
Gutter Fixed at 1:600 Fall
Gutter Flow
(litres/sec)
Roof Area
M2
Gutter Flow
(litres/sec)
Roof Area
M2
Half Round
0.92
44
1.17
56
Square Line
1.70
82
1.81
88
2.34
112
2.50
122
● Fascia Brackets should be positioned so as to avoid the
fixing screws splitting the top edge of any timber fascia
board. All brackets should be secured to the fascia board
with two 25mm x 5mm (1” x 10) screws or one 32mm x 6.5mm
(11/4“ x 14) screw.
2.05
98
2.87
137
● Unions should be fixed using a 25mm x 5mm (1” x 10) screw.
Hi-Cap
2.60
Square Line
Hi-Cap
● Fix Fascia and Union Brackets at required intervals
● Outlets and Angles should be fixed using two
25mm x 5mm (1” x 10) screws.
OUTLET AT CENTRE OF GUTTER RUN
Half Round
5 Fixings:
132
● In areas of heavy snowfall it is recommended that
each fascia bracket is secured using two
25mm x 5mm (1” x 10 screws).
125
2.75
3.41
160
3.95
190
6.14
294
6.25
300
● Rainwater downpipe clips should be fixed using two
32mm x 6.5mm (11/4“ x 14) screws.
3.97
190
5.56
266
● Use round headed screws which should be brass or zinc plated.
6 Lubricate all gutter seals with FloPlast silicone spray lubricant to
ensure an easy fit and to allow for movement caused by expansion and contraction.
7
Working from the Running Outlet insert the back edge of the gutter under the retaining lip of
the wrap around clip. Using slight downward pressure on the gutter snap the front edge of
the retaining clip over the front of the gutter. (Ensure that the marked expansion allowance is kept.)
8
Use a Union Bracket or Angle to join to next gutter length in order to build up a gutter run.
Use a Stopend to complete the run.
9
Downpipe installation starts at the outlet. If an offset is required use two Offset Bends with
or without a short piece of pipe or soil connector or alternatively use an adjustable offset
bend. Ensure a 6mm gap is left at the top of the downpipe for expansion.
10 Pipe Connectors if required should be secured to the wall with a Pipe Clip.
11 At the base of the pipe, fit a Shoe secured with a Pipe Clip or connect downpipe to underground
drainage system using a 110mm x 68mm reducer (SP96).
BS 4576
FloPlast 112/68mm Round Rainwater System
is manufactured to this specification and
standard.
BS EN ISO 9002:1994
FloPlast Pipes and Gutters are manufactured
within a quality management system which
has been assessed and registered by the
British Standards Institution as meeting the
requirements of BS EN ISO 9002: 1994
(certificate no. Q 09318).
0899
112mm GUTTER & FITTINGS
90˚ ANGLE
Half Round 112mm/68mm Rainwater System
92.5˚ OFFSET BEND
CODE
RA1
RK1 FASCIA
BRACKET
RA1 90° ANGLE
■ The original Half Round profile.
■ Pre-fitted gutter seal retaining clip system
for fast user friendly installation.
■ Cost effective solution for both new
build and refurbishment applications.
■ Connects to most other metal or plastic
systems.
112.5˚ OFFSET BEND
CODE
RA2
ANGLE - Any degree
CODE
RA9
■ A practical, easy to install system.
■ Good flow capacity.
CODE
RB1
BS4576
135˚ ANGLE
HALF
ROUND
68mm PIPE & FITTINGS
CODE
RB2
SHOE
CODE
RB3
STOPEND - EXTERNAL
CODE
RE1
RU1 UNION BRACKET
RG2/4 GUTTER
RO1 RUNNING OUTLET
RE1 STOPENDEXTERNAL
PIPE CLIP
CODE
RC1
STOPEND - INTERNAL
CODE
RE2
HOPPER
CODE
FASCIA BRACKET
CODE
RK1
RE1 STOPEND - INTERNAL
RUNNING OUTLET
CODE
RO1
RB2 112.5˚ OFFSET BEND
Universal Hopper
square & round
RHS1
PIPE SOCKET
CODE
RS1
COLOURS
UNION BRACKET
CODE
RU1
DIMENSIONS (mm)
112
RP2.5/4/5.5 PIPE
112.5˚ BRANCH
CODE
RY1
GUTTER (112mm)
CODE
RG4
RG2
68
PIPE
CODE
RP2.5
RP4
RP5.5
52
RS1 PIPE SOCKET
RC1 PIPE CLIP
GUTTER ADAPTOR
CODE
cast iron Ogee R/H
cast iron Ogee L/H
to half round cast iron
RD3
RD4
RD5
UNIVERSAL
RISE & FALL RAFTER BRACKET
CODE
RF1
SPARES/ANCILLARIES
CODE
Gutter Clip
RRC1
Gutter Seal
RRS1
400ml Silicone
Lubricant
SL400
Gutter Guard
(5m pack)
TOP RAFTER BRACKET
CODE
RR1
RB3 SHOE
2 metres, 2.5 metres, 4 metres
and 5.5 metres.
SIDE RAFTER BRACKET
CODE
RR2
FloPlast recommend the use of
lubricant on all gutter seals for
ease of fitting and for improved
performance.
Gutter and pipe code reference
numbers refer to length of run:
114mm GUTTER & FITTINGS
65mm PIPE & FITTINGS
92.5˚ OFFSET BEND
90˚ ANGLE
CODE
RAS1
CODE
RBS1
Square Line 114mm/65mm Rainwater System
135˚ ANGLE
SQUARE
LINE
■ Attractive rectilinear profile.
RAS1 90° ANGLE
RKS1
FASCIA BRACKET
■ Flow capacity in excess of Half Round.
■ Connects to most other metal or plastic
systems.
CODE
RBS2
ANGLE - Any degree
CODE
RAS9
■ Pre-fitted gutter seal retaining clip system
for fast user friendly installation.
■ Cost effective solution for both new build
and refurbishment applications.
112.5˚ OFFSET BEND
CODE
RAS2
ADJ. OFFSET BEND
CODE
RBS5
FloPlast will fabricate any
non-standard angle to special order
RUS1
UNION BRACKET
RGS2/4 GUTTER
RES1
STOPEND
EXTERNAL
STOPEND - EXTERNAL
CODE
RES1
SHOE
CODE
RBS3
STOPEND - INTERNAL
CODE
RES2
ROS1 RUNNING OUTLET
RES2 STOPEND - INTERNAL
PIPE CLIP
CODE
RCS1
FASCIA BRACKET
RCS2
(Flush)
CODE
RKS1
COLOURS
RUNNING OUTLET
HOPPER
CODE
CODE
ROS1
RBS2 112.5° OFFSET BEND
DIMENSIONS (mm)
114
65
RCS1 PIPE CLIP
STOPEND OUTLET
CODE
ROS2
60
RPS2.5/4/5.5 PIPE
Universal Hopper
square & round
PIPE SOCKET
CODE
RSS1
UNION BRACKET
CODE
RUS1
112.5˚ BRANCH
CODE
RYS1
SQ/RD GUTTER ADAPTOR
CODE
RDS1
RSS1 PIPE SOCKET
RCS2 FLUSH PIPE CLIP
Allows downpipes to be fixed
flush to wall.
SQ/RD DOWNPIPE ADAPTOR
CODE
RDS2
GUTTER (114mm)
CODE
RGS4
RGS2
PIPE
CODE
RPS2.5
RPS4
RPS5.5
GUTTER ADAPTOR
CODE
to cast iron ogee R/H
to cast iron ogee L/H
RDS3
RDS4
SPARES/ANCILLARIES
CODE
RISE & FALL RAFTER BRACKET
RBS5 ADJUSTABLE OFFSET BEND
Allows for minimum offset of 25mm
up to a maximum of 65mm.
RHS1
Gutter Clip
RRC1
RF1
Gutter Seal
RRS1
(UNIVERSAL)
400ml Silicone
Lubricant
SL400
Gutter Guard
(5m pack)
CODE
TOP RAFTER BRACKET
CODE
RR1
RBS3 SHOE
SIDE RAFTER BRACKET
FloPlast recommend the use of lubricant on all gutter seals
for ease of fitting and for improved performance.
CODE
RR2
Gutter and pipe code reference
numbers refer to length of run:
2 metres, 2.5 metres, 4 metres
and 5.5 metres.