ModelMCV - Goldberg Systems GmbH

Transcription

ModelMCV - Goldberg Systems GmbH
innovation in energy
MCV
Model
innovation in energy
EV/HEV Battery Cell Testing System
FEATURES & BENEFITS
• Drive simulations with standard Electric Vehicle tests: FUDS,
SFUDS, GSFUDS, DST and ECE-15L
• Drive Cycle Conversion utility automates test program
development from acquired battery usage data
• Constant Current, Power or Voltage Control
• Bipolar capacity for discharging to below zero volts
• Parallel circuit operation for greater flexibility in test
specification
• Assignable Data Channels
• Test control and data management with Bitrode’s VisuaLCN
Lab Client software suite
System Options
Bitrode Model MCV8-100-12
(shown with optional side box)
GENERAL SPECIFICATIONS
Voltage: Current:
Accuracy:
Resolution:
Data Sampling Rate:
0-18V (other voltages optional)
1µA-300A
±0.1% of FS*
16 bit
100ms (other ranges optional)
• Multiple current ranges per circuit
• High impedance cell voltage monitoring
• Temperature compensation - adjusts voltage per battery temperature
• Pressure monitoring
• Internal resistance
• Programmable analog or digital inputs and outputs
• Remote Input Output (RIO) box - reduces excessive cable
lengths when connecting to remote test stations
• Constant resistance discharge
• Customer-specified alarms and faults
• Custom-designed test leads
• Custom-designed cell or battery handling fixtures
*Accuracy values are conservative assuming operation will be through the standard
temperature range of 0-40˚ C and RH from 10-90% (non-condensing). Units calibrated and
maintained in a temperature and humidity controlled environment can expect an accuracy
of 0.02-0.05%FS.
Bitrode, Inc.©2012 www.bitrode.com
innovation in energy
innovation in energy
MCV
Model
EV/HEV Battery Pack Testing System
General Configurations - Contact bitrode for your custom specification requirements
Model*
MVC16-25-12
MCV24-50-12
MCV8-100-12
MCV32-10-12
Model*
MVC16-25-12
MCV24-50-12
MCV8-100-12
MCV32-10-12
Constant Current
Amp Range
0.00-25.00
0.00-50.00
0.00-100.00
0.000-10.000
Charge
Voltage
0.000-18.000
0.000-18.000
0.000-18.000
0.000-18.000
Discharge
Voltage
0.000-18.000
0.000-18.000
0.000-18.000
0.000-18.000
Circuits
Cabinet Input Amps (50 or 60HZ)
Dimensions†
per Three Phase
in/cm
Cabinet
230V400V 480V
W D
H
16
39
22
19
23/59
34/87
78/199
24
107
61
51
67/171
34/87
78/199
8
69
40
33
45/115
34/87
78/199
32
38
22
18
35/89
44/112 78/199
Constant
Wattage
450.00
900.0
1800
120.0
Weight†
lb/kg
1200/540
3000/1350
3000/1350
1800/810
* If required specifications do not appear in this table, contact Bitrode Corporation; custom product engineering is one of our
greatest strengths. Module names are interpreted as follows: MCVxx-yy-zz, where xx indicates number of circuits per cabinet,
yy indicates amperage and zz indicates voltage.
† Dimensions and Weight may vary according to design requirements.
All specifications subject to change.
BITRODE CORPORATION
9787 Green Park Industrial Drive
St. Louis, Missouri 63123 USA
Tel: (636) 343.6112 • Fax: (636) 343.7473
email: [email protected]
web: www.bitrode.com
BITRODE EU/SOVEMA SPA
via Spagna, 13
37069 Villafranca (Verona), Italy
Tel: +39.045.6335711 • Fax: +39.045.6303911
Contact Person: Mr. Roberto Vecchia
Tel: +39.045.6335725 • Mobile: +39.331.6338697
email: [email protected]
BITRODE UK OFFICE
Tel: 44 1242 23111
Contact Person: Mr. Graham Peters
email: [email protected]