Mandible FixBridge TG
Transcription
Mandible FixBridge TG
Mandible FixBridge. For temporary bridging of the mandible. Technique Guide Table of Contents Introduction Mandible FixBridge 2 Surgical Technique Preoperative Planning 2 Surgical Technique 3 FixBridge Components 7 Instruments 8 Set List 9 Product Information Synthes The Mandible FixBridge The Mandible FixBridge is indicated in mandible resection cases where prepositioning of a reconstruction plate prior to the resection is impossible due to the location, size and extension of the tumor. The use of the temporary Mandible FixBridge ensures the proper positioning of the remaining bone segments postresection. Preoperative planning Preoperative planning is especially important during placement of the Mandible FixBridge to ensure that the appliance does not interfere with plate placement. Warning: This description is not sufficient for an immediate application of the instrumentation. Instruction by an experienced surgeon in handling this instrumentation is highly recommended. 2 Synthes Mandible FixBridge Technique Guide Surgical Technique 1 Mark the planned resection zone on the bone. 2 Place the Bone Plate. Use the appropriate Drill Bit for drilling (the first hole may be drilled without the plate in place). If necessary, measure depth now. Insert the chosen screw (2.0 mm or 2.4 mm diameter) through the Bone Plate. Repeat steps on the opposite side of the mandible. Note: It is important to place the bone plates posterior enough on the mandible to avoid interference with the application of the fixation (reconstruction) plate. 3 Choose the appropriate length Vertical Post (30 mm or 50 mm) and fix one to each Bone Plate using the Vertical Post Screws and Hexagonal Screwdriver. Synthes 3 Surgical Technique 4 Place a Tube Clamp over each Vertical Post. Clamp screwheads should face anteriorly. Pass the Vertical Post through the Tube Clamp distal to the screwhead. Important: When assembling the Tube Clamps, take care that the screws pass through the unthreaded clamp first and then into the threaded one. The latter must be positioned so that the threaded part of the clamp finishes off the construction. 5 Choose the correct length Extension Bow (50 mm or 70 mm) and insert its ends through the remaining holes of the Tube Clamps. 6 Adjust the position of the Extension Bow and tighten all screws carefully, since they are fixing the original shape of the mandible. Mandible FixBridge is now in its final position. If the mounted Mandible FixBridge does not hinder the resection, resect and go on to Step 11. Otherwise, continue with Step 7. 4 Synthes Mandible FixBridge Technique Guide 7 Remove the two Vertical Post Screws. 8 Remove the assembled Mandible FixBridge from the mandible as a unit (consisting of Extension Bow, Tube Clamps, and Vertical Posts). Store Mandible FixBridge carefully to avoid any distortion before it is reapplied after resection. 9 Perform the resection. Synthes 5 Surgical Technique 10 Reapply Mandible FixBridge by inserting the Vertical Post Screws into the Bone Plates. Take care to position FixBridge accurately, without deviation. The bone stumps are now in their original relationship to each other. 11 Select and contour the appropriate reconstruction plate and secure it with the screws in the mandibular bone segments. Once the reconstruction is complete, with the condylar position confirmed and the plate in place, remove all components of the FixBridge. 12 Resection is complete with definitive fixation in place. Condylar position and occlusal relationship are indispensable requirements for reconstructing the mandible. The use of the FixBridge ensures that these relationships are maintained throughout the resection. 6 Synthes Mandible FixBridge Technique Guide FixBridge Components 386.72 Bone Plate, 2 holes 386.74 386.75 Vertical Post 30 mm 50 mm 386.76 Vertical Post Screw 386.79 Tube Clamp, complete 386.85 386.87 Extension Bows, complete 50 mm 70 mm Synthes 7 Instruments 314.40 Hexagonal Screwdriver 314.67 1.5 mm/2.0 mm Cruciform Screwdriver Blade with Holding Sleeve, short and 311.03 Handle with mini quick coupling, small 317.835 1.5 mm Drill Bit, 110 mm, Stryker J-latch 8 Synthes Mandible FixBridge Technique Guide Mandible FixBridge Set (102.65) Graphic Cases 301.70 Aluminum Case 302.65 Mandible FixBridge Rack 302.70 Instrument Tray Instruments 311.03 Handle with mini quick coupling, small 312.22 2.0 mm/1.5 mm Double Drill Sleeve 314.40 Hexagonal Screwdriver 314.67 1.5 mm/2.0 mm Cruciform Screwdriver Blade with Holding Sleeve, short 317.435 1.5 mm Drill Bit, 60 mm stop, 85 mm, Stryker J-Latch, 2 ea. 319.52 Depth Gauge for 1.5 mm to 2.0 mm screws FixBridge Components 386.72 Bone Plate, 2 holes, 2 ea. Vertical Posts, 2 ea. 386.74 30 mm 386.75 50 mm 386.76 Vertical Post Screw, 2 ea. 386.79 Tube Clamp, complete, 2 ea. Extension Bows, complete 386.85 50 mm 386.87 70 mm 201.808.98– 2.0 mm Cortex Screws, self-tapping 201.814.98 5 ea.: 8 mm, 10 mm, 12 mm, and 14 mm Also Available 317.832 1.5 mm Drill Bit, 110 mm, Universal / Hall coupling 317.835 1.5 mm Drill Bit, 110 mm, Stryker J-latch 317.838 1.5 mm Drill Bit, 110 mm, mini quick coupling 311.21.98 Tap for 2.0 mm Cortex Screws 100 mm / 38 mm tapping depth (for use only with cortex screws) 401.158– 401.164 2.0 mm Titanium Cortex Screws, 8 mm, 10 mm, 12 mm, and 14 mm, 5/pkg. 401.044– 401.047 2.0 Titanium Cortex Screws, coarse pitch, self-tapping, with PlusDrive recess, 8 mm, 10 mm, 12 mm and 14 mm, 5 / pkg. 04.503.408.05– 2.0 mm Titanium MatrixMandible Screws, 04.503.414.05 self-tapping, 8 mm, 10 mm, 12 mm, and 14 mm, 5 / pkg. Note: For additional information, please refer to package insert. For detailed cleaning and sterilization instructions, please refer to http://us.synthes.com/Medical+Community/Cleaning+and+Sterilization.htm or to the below listed inserts, which will be included in the shipping container: – Processing Synthes Reusable Medical Devices — Instruments, Instrument Trays and Graphic Cases — DJ1305 – Processing Non-sterile Synthes Implants — DJ1304 Synthes 9 Synthes CMF 1302 Wrights Lane East West Chester, PA 19380 Telephone: (610) 719-5000 To order: (800) 523-0322 Fax: (610) 251-9056 © 1996 Synthes, Inc. or its affiliates. All rights reserved. Synthes (Canada) Ltd. 2566 Meadowpine Boulevard Mississauga, Ontario L5N 6P9 Telephone: (905) 567-0440 To order: (800) 668-1119 Fax: (905) 567-3185 PlusDrive and Synthes are trademarks of Synthes, Inc. or its affiliates. www.synthes.com Printed in U.S.A. 8/10 J3146-C
Similar documents
PATIENT SPECIFIC PLATES FOR MANDIBLE Custom made plates for trauma and reconstruction
More information
Medium External Fixator—Delta Frame Ankle Bridge
Drive Adaptor with quick coupling, for 4.0 mm Schanz Screws
More information