Water Heating Catalogue

Transcription

Water Heating Catalogue
CI/SfB
(53.3)
x
July 2012
Water Heating
Catalogue
Introduction
2
A Leading Name
Santon has been a leading name
in water heating for over seventy
years with a comprehensive product
portfolio, which includes vented and
unvented water heaters for domestic,
commercial and industrial use. Its
reputation is built upon manufacturing
top quality, highly reliable products,
designed to meet the most demanding
customer needs.
SPECIFICATION ADVICE: 01603 420128
The company uses the latest techniques in research, development and
manufacturing to ensure that Santon’s product range satisfies all of
its customers’ requirements and represents excellent value for money.
Introduction
Santon is synonymous with innovation. The new PremierPlus
unvented, systemfit and solar cylinder range has brought more
stringent levels of temperature control to an increasingly safety
conscious commercial environment.
3
Customer Support
In today’s demanding market place, a company’s overall reputation
is only as good as the quality of its customer support. To ensure
the very highest level of customer support, our sales and service
hotlines provide direct access to our knowledgeable teams. Our
qualified and experienced team of Area Sales Managers are
available to visit specifiers and installers nationwide.
All Santon products are covered by a minimum two year guarantee.
In the unlikely event of a product failure, our service experts will either
provide an instant solution over the phone or arrange for a prompt
service call from a qualified engineer to quickly remedy the problem.
Whether the need is specification, sales,
installation or service related, Santon is
able to offer the ideal solution.
E-MAIL: [email protected]
Product Selector
Product Selector
Hot water for single basin or sink supply (commercial)
4
Type
Mounting
Vented or
Unvented
Product
Storage Over/UndersinkVented
Aquarius
Storage
UndersinkUnvented Aquaheat
InstantaneousOverbasin
n/a
EV2008
InstantaneousWall Unvented PowerPack
Hot water for two or more basins or sinks (commercial)
Type
Mounting
Vented or
Unvented
Product
Storage
Floor UnventedPremierPlus
Storage
UndersinkUnvented Aquaheat
or Aqualine
InstantaneousWall Unvented PowerPack
Storage
Wall
Vented
R Units
Storage
Ceiling
Vented
Aquaheat SS
or void
Hot water for household use (domestic)
Type
Mounting
Storage
Storage
Storage
Vented or
Unvented
Product
Floor UnventedPremierPlus
Floor
Unvented PremierPlus SystemFit
Floor
Unvented
PremierPlus Solar
Immersion heaters
Type
Water kW MaterialPhasesProduct
or oil loading
Industrial
Water 2 – 54 Superloy/ 1 or 3 MY, MT,
Titanium
LY, MGY,
DY or DT
Industrial
Oil
1 – 6 Mild steel 1 or 3 MO or LO
The pace of product development is such that we reserve the right to
change product specifications without notice. We do, however, strive to
ensure that all information in this catalogue is accurate at the time of going
to publication.
Santon wishes to make it clear that it owns all the original designs of the
products it manufactures (whether or not listed in this catalogue) and that it
will take all necessary legal action, in any part of the world, against any party
found to be manufacturing, selling or otherwise dealing with any article that
infringes Santon’s copyrights or patents in its products, or any other right of
Santon therein.
SPECIFICATION ADVICE: 01603 420128
ContentsPage
PremierPlus Solar
12
Solar Unvented Water Heating
Aquaheat 24
Unvented Electric Water Heating
Aqualine25
Product Selector
PremierPlus6
Unvented Water Heating
Unvented Electric Water Heating
Aquaheat SS
36
Unvented Electric Water Heating
Aquarius40
Vented Electric Water Heating
Taps44
Vented Electric Water Heating
EV 2008 / EV 2008 No Touch
46
Hand Hygiene
Speediboil50
Drinking Water
PowerPack52
Instantaneous Water Heating
R Units
54
Combination Storage
Immersion Heaters 56
Industrial
Data60
Useful Information
E-MAIL: [email protected]
5
PremierPlus
Unvented Water Heaters
Mains Pressure Unvented Water Heating
6
Designed and manufactured in the UK the PremierPlus range of
unvented cylinders lead the way in cost effective mains pressure
water heating.
Built to the highest standards from Duplex stainless steel, the units
offer exceptional corrosion resistance and long-life expectancy.
Advanced primary coil and cold water controls design gives rapid
reheat and good flow rate performance. It provides mains pressure
showering and is suitable for use in new-build or refurbishment
schemes for domestic and commercial applications. PremierPlus
cylinders are available from 100 to 300 litres, in both direct and
indirect models with pre-plumbed and solar options.
All models have 50mm of CFC/HCFC-free (ODP zero) foam insulation
to give improved heat loss and are finished in a stylish and durable
white plastic-coated, corrosion-proofed steel casing with grey high
impact thermoplastic moulded top and bottom covers.
Features and Benefits
• Duplex stainless steel for longer life.
• Flexible siting of cylinder installation.
• C
omplete package incorporates
safety and hot water controls.
• S
avings on installation from
simplified plumbing and electrical
connections.
ains pressure hot water for more
• M
powerful showers and faster filling
baths.
• E qually suited to new build and
refurbishment projects.
• Fully indemnified design service.
• No cold feed cistern required.
• No shower pump required.
• No anode to maintain or replace.
• Fully factory tested for reliability.
• Fast recovery rates.
• Safe, economical performance.
• No loft pipes to freeze up.*
• 3
0 year cylinder guarantee, 5 years
on expansion vessel and 2 years on
element and all other controls with
on-site parts and labour.
*Assumes
Sealed System Boiler Installation.
SPECIFICATION ADVICE: 01603 420128
PremierPlus
The Installer-Friendly Unit
Following extensive surveys of
installers’ preferences, Santon has
designed PremierPlus with the
installer in mind. All of the plumbing
and electrical connections are
located to give easy access during
installation. Plumbing connections
are 22mm compression. Electrical
connections are made to an
integrated wiring centre which
facilitates a neater, trouble-free
and simpler installation.
Unvented Water Heaters
Simple Installation
Heat Exchanger – Indirect Units
7
A high efficiency ‘coil-in-coil’ heat
exchanger is situated at the base of
the unit which ensures that virtually
all of the water is heated. This
compares with a typical side entry
single coil heat exchanger which
typically heats only approximately
80% of the water content. The
design also ensures that there is
rapid reheat when water is used
bettering CHeSS* recommended
good practice.
*CHeSS – Central Heating System
Specifications. General information leaflet 59.
Typical Installation of an Indirect PremierPlus
E-MAIL: [email protected]
PremierPlus
Accessory Kits
Unvented Water Heaters
Duplex Stainless Steel Construction
8
This high strength, high quality material
ensures an unsurpassed standard of
corrosion protection without the need
for anodes. Manufactured in the UK to
the highest standards in a BS EN ISO
9001:2008, ISO 14001:2004 and BS
OHSAS 18001:2007 registered factory,
all units are pressure tested to 15 bar.
Safety
The high strength Duplex stainless steel
cylinder is manufactured using stringent
quality control procedures and is pressure
tested to over 1½ times its maximum
operating pressure. All PremierPlus
units have fully integrated thermostatic
controls and thermal cut-outs for both
direct and indirect heating. A higher
level of thermal safety is provided by
the factory-fitted temperature and
pressure relief valve.
Cold Water Controls
An integrated cold water control set,
exclusively designed for the PremierPlus,
and comprising of a pressure reducing valve
and strainer, expansion relief valve and
check valve reduces installation time by
incorporating three components into one
and gives significant improvements in flow
rate across a range of inlet pressures.
Guarantee
The use of Duplex stainless steel means
that the PremierPlus comes with a 30 year
on-site parts and labour transferable
guarantee for the cylinder. The expansion
vessel has a 5 year on-site parts and labour
guarantee and all other valves and fittings
supplied with the unit are covered for a
period of 2 years.
SPECIFICATION ADVICE: 01603 420128
PremierPlus
Selection and Ordering Guides
Property type
Direct model
PP100E or PP120E
Bedsit
1-2 bed with 1 bath/shower PP150E or PP170E
3 bed with 1 bath/shower PP170E or PP210E
4 bed with 1 bath/shower PP210E or PP250E
2-3 bed with 2 baths/showerPP210E or PP250E
4-5 bed with 2 baths/showerPP250E or PP300E
4-5 bed with 3 baths/showerPP300E
Light commercial usage
PP250E or PP300E
Note:
All sizings calculated using BS6700
60 ltr hot water per bath
60 ltr hot water per shower
15 ltr hot water per sink
7 ltr hot water per basin
Indirect model
PP100B or PP120B
PP150B
PP170B or PP210B
PP210B or PP250B
PP210B or PP250B
PP250B or PP300B
PP300B
PP250B or PP300B
This selection chart is for guidance
only. Hot water requirements will
vary dependent on bath size, usage
patterns, etc.
9
Please contact the Specification Department for further advice.
Ordering Guide
Product Ltrs ElementCoil
Code
RatingRating
Direct
(kW @240V) (kW)
PP100E
PP120E
PP150E
PP170E
PP210E
PP250E
PP250E 9kW PP300E
PP300E 9kW 94
94
94
94
94
94
94
94
94
050
050
050
050
050
050
050
050
050
318
319
320
321
322
323
326
324
334
100
120
150
170
210
250
250
300
300 1
2
2
2
2
2
3
2
3
x
x
x
x
x
x
x
x
x
3
3
3
3
3
3
3
3
3
-
94
94
94
94
94
94
94
94
94
050
050
050
050
050
050
050
050
050
327
328
329
330
331
332
347
333
348
100
120
150
170
210
250
250
300
300
1
1
1
1
1
1
2
1
2
x
x
x
x
x
x
x
x
x
3
3
3
3
3
3
3
3
3
11.8
12.5
16.4
16.0
18.3
20.0
20.0
20.0
20.0
Indirect
PP100B
PP120B
PP150B
PP170B
PP210B
PP250B
PP250B 6kW
PP300B
PP300B 6kW
Unvented Water Heaters
Selection Guide
E-MAIL: [email protected]
PremierPlus SystemFit
Unvented Water Heaters
Pre-plumbed Unvented Water Heating
Santon’s unvented PremierPlus cylinder is available in a pre-plumbed
format. PremierPlus SystemFit has been designed to significantly reduce
installation time whilst still offering mains pressure water heating.
Each factory-assembled unit comes pre-plumbed and pre-wired with
230V central heating controls, pump, two 2-port motorised valves,
automatic by-pass and balancing valves. This timesaving PremierPlus
SystemFit package not only speeds installation but also significantly
enhances the quality and integrity of the central heating system thus
eliminating costly callbacks.
10
SPECIFICATION ADVICE: 01603 420128
PremierPlus SystemFit
Pre-plumbed Unvented Water Heating
• Duplex stainless steel cylinder.
• 120, 150, 170, 210, 250 and 300 litre models.
• Programmable thermostat with timed Domestic Hot Water
(DHW) control.
• Primary system pressure gauge.
• Coil-in-coil heat exchanger.
• Cold-water control set.
• Remote expansion vessel.
• Separate central heating and hot water zones.
• No maintenance three speed circulating pump.
Unvented Water Heaters
Features
• Automatic by-pass valve for system efficiency.
• Load balancing valve for indirect coil efficiency.
• Connections for vented and unvented heating primaries.
• Primary system filling loop.
• Auto air vent.
• Connection for 2nd CH zone on 170 litre and above.
• Primary system expansion vessel (supplied loose for on-site fitting).
Benefits
• Simplified on-site installation.
• Up to 70% quicker to install.
• Factory assembled for reliability – reduces costly call-backs and delays.
• Consistent electrical and plumbing layout – neat, professional finish.
• Greater customer satisfaction.
• B
S EN ISO 9001:2008, ISO 14001:2004 and BS OHSAS 18001:2007
quality assured.
• Kiwa and Nemko approved and CE marked.
• 30 year on-site parts and labour cylinder guarantee.
• 5 year on-site parts and labour expansion vessel and cold water
controls guarantee.
• 2 year on-site parts and labour guarantee on element and all other
controls.
E-MAIL: [email protected]
11
PremierPlus Solar
Solar Water Heating
Solar Unvented Water Heating
12
Climate change is an undeniable fact which has increased the focus
on alternative energy sources. Solar energy direct from the sun is a
source of energy which, when harnessed, can be converted into heat
to generate hot water for the home, whilst at that same time helping
to reduce carbon emissions and reduce global warming.
PremierPlus Solar has been designed specifically for solar applications.
It offers all of the benefits of the standard PremierPlus unvented
cylinder to give powerful mains pressure showering and fast filling
baths, with the added benefit of lower running costs – as much as
60% less than traditional systems*.
Designed for use with a wide range of solar systems available in the
UK, PremierPlus Solar is an environmentally friendly and efficient
way of providing domestic hot water. Unlike some other ‘twin coil’
cylinders (which simply use heating coils designed for traditional
boiler heated cylinders), PremierPlus Solar cylinders have a purpose
designed solar heating coil at the base of the cylinder, which ensures
maximum heat input and efficiency from the solar energy.
Available in a choice of capacities from 170 to 300 litres, with a
choice of direct (electric auxiliary heat input) or indirect (gas, oil
or electric boiler auxiliary heat input) versions.
SPECIFICATION ADVICE: 01603 420128
PremierPlus Solar
Solar Unvented Water Heating
During the summer months as much as 100% of the energy used by
PremierPlus could be solar*. In winter, despite the lower intensity of the
Sun’s rays and fewer daylight hours as much as 20% could be solar*.
On average throughout the year up to 60% of a dwelling’s hot water
requirement can be provided by solar power*. The balance is provided by
traditional means; either indirect (via a gas, oil or electric boiler heating a
second coil within the cylinder) or direct (via electric immersion heaters
in the cylinder).
How does PremierPlus Solar work?
The Solar cylinder is used in conjunction with solar panels (not supplied)
which convert energy collected from the Sun’s rays to heat a water / glycol
liquid in its pipe work. This liquid is circulated through a specially designed
solar coil in the base of the cylinder where the liquid transfers its heat to the
water stored before being pumped back to the solar panel to be re-heated.
The design of this coil allows maximum solar gain to be achieved ensuring
that the solar system is being used to its full potential.
*savings vary depending on type of solar system used, location and usage patterns.
E-MAIL: [email protected]
Solar Water Heating
How much of your water heating energy needs can be provided
by solar?
13
PremierPlus Solar
Solar Unvented Water Heating
Solar Water Heating
Which unit to use
The choice of capacity for traditional cylinders is based on the hot water
requirements of the dwelling. With solar cylinders, there are a number
of other factors which need to be taken in to account such as the solar
collectors used and where they are sited. Additionally the amount of usable
hot water will vary depending on the solar gain available on a given day.
For that reason it is important to ensure that the auxiliary heated volume
of the cylinder is capable of meeting the dwelling’s hot water demands
on days where solar gain will be low, such as during winter months.
Our specification team are available to provide cylinder sizing advice on
01603 420128.
Potterton Solar
14
The Santon PremierPlus Solar cylinders
are perfectly matched with the
Potterton Solar systems.
• A range of On-roof and In-roof
collector packages available.
• Reduces CO² emissions and
domestic fuel bills.
• Easy to fit range of packaged
solutions makes it easy for installers
to move to solar energy.
• National Technical Support and After
Sales Service from a single source.
For more details call 0844 871 1560
or visit www.potterton.co.uk
SPECIFICATION ADVICE: 01603 420128
PremierPlus Solar
Unvented System Benefits
Features
• Duplex stainless steel cylinder for long life.
1
• Choice of direct or indirect auxiliary heat input.
2
• Specially designed solar coil for maximum solar efficiency.
• Complete package includes:
– Safety and hot water controls.
4
– Remote expansion vessel.
• High flow rates for improved hot water delivery.
3
Solar Water Heating
• M
ains pressure (unvented) hot water for balanced supply to showers and mixers.
• Compatible with a wide range of UK solar systems.
• Lower running costs and reduced energy bills.
• Environmentally friendly – reduced carbon emissions.
• Equally suited for New Build or Refurbishment projects.
• Fully indemnified design service.
• 30 year on-site parts and labour cylinder guarantee.
1
4
2
4
3
E-MAIL: [email protected]
15
PremierPlus
Unvented Water Heaters
Technical Specification
ø550
29
A
C
16
81
B
D
45º
25º
30º
45º
Dimensions
Direct
A
B
C
D
Weights (kg)
(mm)(mm)(mm)(mm) Empty
Full
PP100E
PP120E
PP150E
PP170E
PP210E
PP250E
PP250E 9kW
PP300E
PP300E 9kW
784306493
906306615
1090 306 800
1216 306 925
1474 306 1184
1726
306 1391
17263061391
20403061715
20403061715
-
-
-
-
-
-
-
-
-
23
123
25
145
28178
29199
36 246
45 295
45295
55355
55355
Indirect
PP100B
PP120B
PP150B
PP170B
PP210B
PP250B
PP250B 6kW
PP300B
PP300B 6kW
784354493315
906354615315
1090354800315
1216354925315
14743541184315
17263541391315
17263541391315
20403541715315
20403541715315
SPECIFICATION ADVICE: 01603 420128
25
125
27
147
31
181
33
203
41251
50300
50300
60360
60360
PremierPlus
Specification
Nominal Capacities
100, 120, 150, 170, 210, 250 & 300
litres.
Element
Alloy sheathed element, incorporated into
an easily removable heater plate, should
replacement be necessary.
Rated 3.0kW @ 240V.
Outer Casing
White plastic-coated, corrosion-proofed
steel with grey high impact thermoplastic
moulded top and bottom covers.
Thermal Insulation
CFC/HCFC free (ODP zero) fire retardant
expanded polyurethane. 50mm thickness.
GWP 3.1 (Global Warming Potential).
Inner Container
Duplex stainless steel, pressure tested to
15 bar.
Primary Coil
22mm diameter stainless steel.
Coil-in-coil design for improved
performance.
Thermostat
Element thermostat adjustable from
10°C to 70°C.
Safety Features
All Models:
Temperature and pressure relief valve,
factory set to operate at 10 bar and 90°C.
High limit thermostat, factory set at 80°C.
Direct Models:
Manually-resettable cut-out, set to 80°C.
Anode
None required.
Approvals
CE marked. Nemko approved.
Kiwa approved to UK water supply
regulations.
Kiwa approved for Building Regulation G3.
Manufactured in the UK in a BS EN ISO
9001:2008, ISO 14001:2004 and BS
OHSAS 18001:2007 registered factory.
Guarantee
On-site parts and labour from date
of purchase.
Cylinder – 30 years.
Expansion vessel – 5 years.
Cold Water Control Kit – 5 years.
Element and other controls – 2 years.
Installation
Unvented units over 15 litre capacity
must be installed by a competent installer
in accordance with Local Regulations:
England & Wales – Building Regulation G3.
Scotland – Technical Standards P3.
N. Ireland – Building Regulation P5.
Fixing
Feet on bottom moulding for floor
mounting.
Plumbing Connections
Inlet/Outlet.
22mm compression fittings / ¾" BSP
parallel thread.
Indirect Coil
22mm compression fittings / ¾" BSP
parallel thread.
Temperature and Pressure Relief Valve
15mm compression outlet.
Cold Water Control
Integrated cold water control set
comprising pressure reducing valve and
strainer – factory set at 3.5 bar, expansion
relief valve – factory set at 6 bar and
check valve. 22mm compression fittings.
Tundish (supplied as part of kit) –
15mm compression inlet and 22mm
compression outlet. Mains pressure; Min
1 bar, Max 16 bar. A 2-port motorised
valve is supplied with Indirect models.
Flow Rates
Up to 55 litres per minute @ 6 bar
pressure.
Operating Pressure
3.5 bar.
Expansion Relief Valve Pressure
6 bar.
Operating Temperature
Recommended 60°C.
Adjustable from 10°C to 70°C.
Water Expansion
Remote expansion vessel – 12 litre vessel
supplied with 100, 120 and 150 litre
models. 18 litre vessel supplied with
170 and 210 litre models. 24 litre vessel
supplied with 250 and 300 litre models.
Minimum Water Supply Requirements
Recommended minimum supply pressure
– 1.5 bar/20 l/min flow rate.
If there are any doubts about water
supply pressure or flow rates, please
contact our Specification Advice Team
to discuss.
Secondary Circulation
Via 22 x 22 x 15mm swept tee, which
should be fitted to the inlet pipework.
A swept tee is available as an optional
accessory – part no. 94 970 033.
Secondary circulation is not
recommended for direct electric units
being used on off-peak electricity tariffs.
Pressure Testing
Units are tested to 15 bar.
Compatible Boilers
Gas, Electric or Oil fired – open vent or
sealed system type, fitted with integral
control thermostat and cut-out.
Tundish
15mm compression inlet and 22mm
compression outlet.
Electrical
Direct Models:
Connection is to the combined
thermostat/thermal cut-out housed within
the integrated controls housing. The
electrical supply must be permanently
connected via a double pole linked
isolating switch with a minimum break
capacity of 13A.
Indirect Models:
Controls should be wired to the boiler,
programmer etc. in accordance with the
control scheme being used.
All electrical wiring must conform to the
latest IEE Wiring Regulations.
E-MAIL: [email protected]
Unvented Water Heaters
Technical Specification
17
PremierPlus SystemFit
Pipework layout will vary by model
ø550
A
284
309
C
284
Unvented Water Heaters
Technical Specification / Ordering Guide
B
402
256
D
412
18
Dimensions
Model
PP120B
PP150B
PP170B
PP210B
PP250B
PP300B
A
B
C
D
Weights (kg)
(mm) (mm) (mm) (mm) EmptyFull
SF
SF
SF28
SF28
SF28
SF28
936 382 728
1119 563 907
1245 691 1039
1503 962 1300
1755 1139 1460
2069 1460 1805
411
446
501
501
501
501
34183
42211
45240
51262
58309
68368
Ordering Guide
Model
PP120B
PP150B
PP170B
PP210B
PP250B
PP300B
Product Code
SF
SF
SF28
SF28
SF28
SF28
94
94
94
94
94
94
050
050
050
050
050
050
340
341
342
343
344
345
Litres
Nom.
120
150
170
210
250
300
Element Rating Coil Rating
kW @ 240V
kW
1
1
1
1
1
1
x
x
x
x
x
x
3
3
3
3
3
3
SPECIFICATION ADVICE: 01603 420128
12.5
16.4
16.0
18.3
20.0
20.0
PremierPlus SystemFit
Specification of cylinder
See PremierPlus, page 17.
Specification of components
­­­­­ anfoss TP9000 Programmable room
D
thermostat with timed Domestic Hot
Water (DHW) Control
Built in hot water time control.
Remote room temperature sensor.
Chrono-proportional control on/off.
Frost protection setting.
Easy to use overrides.
Up to 6 time/temperature changes per
day.
7 day, 5/2 or 24 hour operation.
Wallplate construction.
Room temperature control range 5°C
to 30ºC.
Holiday mode.
Programmer dimensions – Width 135mm,
Height 88mm, Depth 32mm.
Sensor dimensions – Width 61mm,
Height 45mm, Depth 22mm.
Designed to meet BS EN60730-2-7 and
EN60730-2-9.
Maximum ambient temperature 45ºC.
Timing accuracy ±1 minute.
Switch rating 230Vac, 50/60Hz, 3(1)A.
Switching action 2x SPDT, type 1BS.
Power supply 230Vas, 50Hz
Memory back up retained for life of
product.
Honeywell two-port valve
For the central heating and domestic
hot water.
Model no V4043H.
Voltage rating 230V ac 50Hz.
Power consumption 6W.
Primary water temp range 5°C to 88ºC.
Max ambient temperature 50ºC.
Automatic by-pass valve
Model no RWC Diff 391 901.
Working pressure 10 bar.
Setting range 0.1 to 0.5 bar differential
pressure.
Max primary water temperature 120°C.
Pump
Model no. Grundfos UPS15-60.
Working pressure 10 bar max.
Voltage rating 230V ac 50Hz.
Starting capacitor 2µF.
Power consumption
Speed setting I 40W.
Speed setting II 65W.
Speed setting III 95W.
Enclosure protection IP42.
Installation
Unvented units over 15 litre capacity
must be installed by a competent installer
in accordance with Local Regulations:
England & Wales – Building Regulations
G3.
Scotland – Technical Standards P3.
N. Ireland – Building Regulations P5.
Fixing
For floor mounting.
Plumbing Connections
Inlet: 22mm compression. Outlet: 22mm
compression / ¾" BSP male.
Primary connections: 22mm O/D Copper
on 120/150L models / 28mm OD Copper
on other models. ½" T&P relief valve
15mm compression outlet supplied fitted.
Cold Water Control
22mm HiFlo cold water valve assembly
comprising 3.5 bar pressure reducer, line
strainer, non-return valve. Expansion core
unit comprising 6 bar expansion valve
and check valve factory fitted. Cold water
control valve (3.5 bar) is supplied for use
with mains pressure of 20 bar to 1.5 bar,
at the lower pressure, performance will
be reduced accordingly. Normal working
pressure is 3.5 bar.
Water Expansion
Remote expansion vessel 12 litre (120 +
150), 18 litre (170 + 210) and 24 litre
(250 + 300). NOTE: A separate expansion
vessel (12 litre) is supplied for sealed
primary systems.
Flow Rates
Up to 55 litres per min @ 6 bar pressure.
Minimum Water Supply Requirements
20 litres per minute flow and 1.5 bar
pressure. (At lesser values, the unit will
operate but outlet flow rates may be
unacceptable, especially with multiple
draw-offs).
Please contact our Specification Advice
Team to discuss specific site conditions if
the above minimum requirement cannot
be met.
Secondary Circulation
Via 15mm tee piece on inlet pipe
(supplied capped). A WRAS listed bronze
circulating pump (not supplied) will be
required.
Compatible Boilers
Electric, gas or oil fired – sealed system
or open vent type, fitted with integral
control thermostat and thermal cut-out.
Tundish
15mm compression inlet and 22mm
compression outlet factory fitted.
Electrical
Connection is direct to terminals in
the immersion heater which must be
permanently connected to the supply
through a double-pole linked isolating
switch with a minimum breaking capacity
of 13A. Indirect controls should be wired
to the boiler, in accordance with the
control scheme being used. All electrical
installation must conform to the latest IEE
Wiring Regulations.
Santon’s Specification Advice Team is
available to discuss requirements for
specific projects, applications and product
selection.
E-MAIL: [email protected]
Unvented Water Heaters
Technical Specification
19
PremierPlus Solar
Technical Specification
Direct
Solar Water Heating
ø550
A
Indirect
ø550
29
A
ø550
29
29
29
C
B C
20
412
370
370
412
D
A
BC C
B C
D
81
412
370
412
81
30º
45º
30º
45º
Dimensions
Direct
A
B
C
D
Weights (kg)
(mm) (mm) (mm) (mm) EmptyFull
PP170ESOLAR
PP210ESOLAR
PP260ESOLAR
PP300ESOLAR
1245
1502
1795
2067
-
-
-
-
925
1184
1411
1715
-
-
-
-
35.5205.5
42.5255.5
58.0318
61.5361.5
1401
1502
1760
2067
923
1095
1258
1573
1019
1184
1391
1715
732
1009
1160
1438
45.5235.5
47.5257.5
56.5306.5
66.5366.5
Indirect
PP190BSOLAR
PP210BSOLAR
PP250BSOLAR
PP300BSOLAR
SPECIFICATION ADVICE: 01603 420128
PremierPlus Solar
Technical Specification / Ordering Guide
Auxiliary Auxiliary Solar Recovery Heating
Coil
Coil Coil
Time
Time
Rating SurfaceSurface
AreaArea
(kW) (m²) (m²) (mins)(mins)
Direct
PP170ESOLAR
-
-
PP210ESOLAR
-
PP260ESOLAR
-
PP300ESOLAR
-1.1-126
-1.1-147
-1.1-178
-1.1-210
Indirect
PP190BSOLAR 15.0
PP210BSOLAR15.0
PP250BSOLAR18.8
PP300BSOLAR18.8
0.61 0.68
0.79
0.79
1.1
1.1
1.1
1.1
22
17
19
22
-
Solar Water Heating
Coil Areas
21
Cylinder Capacities and Performance
Direct
Total
Auxiliary solartop-up
heated
hot water
capacitycapacity
(litres)
(litres)
PP170ESOLAR170
PP210ESOLAR210
PP260ESOLAR260
PP300ESOLAR300
Standard Heatloss
(kWh/24h)(kWh/365d)
120
140
170
200
1.40
1.70
1.98
2.28
511
621
723
832
120
120
145
175
1.52
1.70
1.96
2.28
555
621
715
832
Indirect
PP190BSOLAR190
PP210BSOLAR210
PP250BSOLAR250
PP300BSOLAR300
Ordering Guide
Product
Capacity
Nominal CodeAuxiliary
Element
@ 240V
Direct (litres)(kW)
PP170ESOLAR PP210ESOLAR
PP260ESOLAR
PP300ESOLAR
94
94
94
94
050
050
050
050
309
336
310
338
170
210
260
300
1
2
2
2
x
x
x
x
3
3
3
3
94
94
94
94
050
050
050
050
440
441
442
443
190
210
250
300
1
1
1
1
x
x
x
x
3
3
3
3
Indirect
PP190BSOLAR PP210BSOLAR
PP250BSOLAR
PP300BSOLAR
E-MAIL: [email protected]
PremierPlus Solar
Solar Water Heating
Technical Specification
22
Specification­­
Guarantee
Nominal Capacities
190, 210, 250 & 300 litres (indirect).
170, 210, 260 & 300 litres (direct).
Element
Long-life Superloy 825 sheathed element,
incorporated into an easily removable
heater plate, should replacement be
necessary. Rated 3.0kW @ 240V.
Outer Casing
White plastic-coated, corrosion-proofed
steel with grey high impact thermoplastic
moulded top and bottom covers.
Thermal Insulation
CFC/HCFC free (ODP zero) fire retardant
expanded polyurethane. 50mm thickness.
GWP 3.1 (Global Warming Potential).
Inner Container
Duplex stainless steel, pressure tested to
15 bar.
Primary Coil (for auxiliary heating
boiler)
22mm diameter stainless steel.
Coil-in-coil design for improved
performance.
Solar Coil
25mm diameter stainless steel.
Coil-in-coil design and large surface area
for improved performance.
Thermostat
Element thermostat adjustable from
10°C to 70°C.
Factory fitted cylinder thermostat
adjustable to 70°C for auxiliary heating
source.
A pocket is provided for solar controls
suitable for insertion of solar controller
temperature probe.
Safety Features
All Models:
Temperature and pressure relief valve,
factory set to operate at 10 bar and 90°C.
High limit thermostat, factory set at 80°C
Direct Models:
Manually-resettable cut-out, set to 80°C.
A 2-port motorised valve is supplied
with twin coil models to provide overtemperature protection when heating
using the auxiliary heating (boiler) coil.
A factory-fitted thermal cut-out is
provided for integration in to a solar
circuit.
Anode
None required.
Approvals
Kiwa and Nemko approved. CE marked.
Manufactured in the UK in a BS EN ISO
9001:2008, ISO 14001:2004 and BS
OHSAS 18001:2007 registered factory.
The PremierPlus Solar Duplex stainless
steel vessel carries a full 30 year on-site
parts and labour transferable guarantee
against faulty manufacture or materials
provided that:
• It has been correctly installed as per the
instructions contained in the instruction
manual and all relevant Codes of Practice
and Regulations in force at the time of
installation.
• It has not been modified in any way, other than by Santon.
• It has not been frost damaged.
• It has only been used for the storage of potable water.
• It has not been tampered with or been
subjected to misuse or neglect.
• Within 60 days of installation the user
completes and returns the certificate
supplied along with the proof of
purchase to register the product.
• It has been installed in the United Kingdom.
Expansion vessel and hot water controls
are guaranteed for a period of 5 years
from the date of purchase. The PremierPlus
Solar components, immersion heater
and thermal controls are guaranteed
for a period of 2 years from the date of
purchase. Evidence of purchase and date
of supply must be submitted.
The unit is not guaranteed against
damage due to frost.
The guarantee is transferable.
This guarantee does not affect your
statutory rights.
SPECIFICATION ADVICE: 01603 420128
PremierPlus Solar
Technical Specification
Unvented units over 15 litre capacity
must be installed by a competent installer
in accordance with Local Regulations:
England & Wales – Building Regulation
G3.
Scotland – Technical Standards P3.
N. Ireland – Building Regulation P5.
Fixing
Feet on bottom moulding for floor
mounting.
Plumbing Connections
Inlet/Outlet.
22mm compression fittings / ¾" BSP
parallel thread.
Indirect Coil
22mm compression fittings / ¾" BSP
parallel thread.
Solar Coil
22mm compression fittings / ¾" BSP
parallel thread.
Temperature and Pressure Relief Valve
15mm compression outlet.
Cold Water Control
Integrated cold water control set
comprising pressure reducing valve and
strainer – factory set at 3.5 bar, expansion
relief valve – factory set at 6 bar and
check valve. 22mm compression fittings.
Mains pressure
Min 1.0 bar, Max 16 bar.
Flow Rates
Up to 55 litres per minute @ 6 bar
pressure.
Operating Pressure
3.5 bar.
Expansion Relief Valve Pressure
6.0 bar.
Operating Temperature
Recommended 60°C.
Adjustable 10 – 70°C on auxiliary heating
controls.
Water Expansion
24 litre remote expansion vessel supplied
with all models.
Minimum Water Supply Requirements
Recommended minimum supply pressure
– 1.5 bar/20 l/min flow rate. If there are
any doubts about water supply pressure
or flow rates, please contact our Specification
Advice Team to discuss.
Secondary Circulation
½" BSP female connection provided.
Secondary circulation is NOT
recommended for units using off-peak
electricity tariffs for auxiliary heating.
Pressure Testing
Units are tested to 15 bar.
Compatible Boilers
Electric, gas or oil fired – open vent or
sealed system type, fitted with integral
control thermostat and cut-out.
Tundish
15mm compression inlet and 22mm
compression outlet.
Electrical
The solar thermal cut-out (factory-fitted)
should be wired in series with the solar
controls (not supplied).
Direct Models:
Connection is to the combined
thermostat/thermal cut-out, housed
within the integrated controls housing.
The electrical supply must be permanently
connected via a double pole linked isolating
switch with a minimum break capacity
of 13A.
Indirect twin coil models:
Controls should be wired to the boiler,
programmer etc. in accordance with the
control scheme being used.
The solar coil must be connected to a
fully pumped solar primary system that
should be controlled by a suitable solar
controller and hydraulic set. The solar
controller temperature sensor must be
inserted in the pocket supplied on the
heater. All electrical wiring must conform
to the latest IEE Wiring Regulations.
E-MAIL: [email protected]
Solar Water Heating
Installation
23
Aquaheat
Unvented Water Heaters
Commercial Unvented Water Heaters – 15 litres and under
Santon is one of the leading brands in the UK for unvented water
heating. For commercial applications, unvented water heating has a
number of advantages over more traditional methods. For example,
one unvented unit can supply a number of outlets without the need
for special taps. As a result, the unvented option can often prove to
be more cost effective to install than a traditional vented system.
Unvented water heaters are connected to the mains water supply
with the advantage that full mains pressure can be obtained from
both the hot and cold taps.
Aquaheat is a range of small
unvented water heaters available in
capacities of 7, 10 and 15 litres.
Featuring copper inner containers,
Aquaheat provides a cost effective
solution for a variety of commercial
applications including dishwashing,
handwashing and low demand
canteen and workshop use.
24
Ease of installation has long been a
trademark of Santon products and
this range is no exception with the
units ideally suited to both floor
and wall mounting.
Aquaheat units are supplied with
an Expansion Relief Valve, ensuring
the Santon reputation for supplying
safe, quality products is maintained.
Commercial Unvented
Selection Guide
Capacity of Water Heater
7 litres 10 litres
15 litres
Number
of Basins
1–2
2–3
3–4
Note: These figures are for guidance only
and local conditions should be taken into
account when sizing the installation.
For full details contact our Specification Advice Hotline on 01603 420128
or fax 01603 420229.
SPECIFICATION ADVICE: 01603 420128
Aqualine
Aqualine is the ultimate in electric unvented water heating.
All operational and safety controls are contained within the case.
This includes a TMV2 thermostatic blending valve which allows the
unit to store water at a high temperature and dispense at handwash
temperature. Water stored above 60ºC not only gives more useable
blended water output, it also considerably reduces the possibility
of harbouring bacteria, making aqualine the ideal product where
‘safe’ hot water is required – for example schools, nursing homes
and nurseries.
The range features 7, 10 and 15
litre models, with the latter available
in 3kW and 4.5kW loadings. This
enables the specifier and installer to
cover applications from light duty
commercial handwashing to multioutlet installations.
Each unit contains a factory-fitted
pressure and temperature relief
valve, TMV2 thermostatic blending
valve, a control thermostat and a
resettable over-temperature cut-out
for additional safety.
Commercial Unvented
Selection Guide
Capacity of Water Heater
7 litres 10 litres
15 litres
Number
of Basins
1–2
2–3
3–4
Note: These figures are for guidance only
and local conditions should be taken into
account when sizing the installation.
For full details contact our Specification Advice Hotline on 01603 420128
or fax 01603 420229.
E-MAIL: [email protected]
Unvented Water Heaters
Commercial Unvented Water Heaters – with TMV2 Thermostatic
Blending Valve
25
Small Unvented
Unvented Water Heaters
Installing Commercial Unvented Water Heaters and Kit Selector
26
The following information is intended as a guide – if in any doubt,
please contact our Specification Advice Hotline on 01603 420128 or
fax 01603 420229.
Small Unvented Installation
(Up to 15 litres in capacity)
When water is heated, it expands and increases in volume by up to 4%.
This increase needs to be accommodated within the system.
With unvented water heaters below 15 litres in capacity, such
expansion may be accommodated within the cold water supply pipe
provided all of the following conditions are met:
A.The maximum supply pressure is below 4.1 bar.
B.The minimum length of the supply pipework from the heater to the nearest cold draw-off is not less than that specified for the heater used.
C.The expansion in the cold water main is not prevented or restricted by a stop valve, non-return valve, water meter or similar device.
A typical installation of a Santon Aquaheat without expansion kit
A typical installation of a Santon Aqualine without expansion kit
For installations where any of the above conditions cannot be met,
an expansion vessel and other relevant accessories must be used to
accommodate expansion.
In all installations where the supply pressure exceeds 4.1 bar, a pressure
reducing valve must be fitted along with other necessary valves.
SPECIFICATION ADVICE: 01603 420128
Aquaheat
Installing Commercial Unvented Water Heaters and Kit Selector
For inlet water pressure up to 4.1 bar where expansion
back down the mains is not possible (using kit ALK05)
Unvented Water Heaters
For inlet water pressure up to 4.1 bar (with no additional kits used)
27
For inlet water pressure above 4.1 bar (using kit ALK04)
E-MAIL: [email protected]
Aqualine
Installing Commercial Unvented Water Heaters and Kit Selector
Unvented Water Heaters
For inlet water pressure up to 4.1 bar (with no additional kits used)
For inlet water pressure up to 4.1 bar where expansion
back down the mains is not possible (using kit ALK02)
28
For inlet water pressure above 4.1 bar (using kit ALK01)
SPECIFICATION ADVICE: 01603 420128
Small Unvented
Installing Commercial Unvented Water Heaters and Kit Selector
Is the supply pressure
guaranteed to be (and
remain) below 4.1 bar
YES
NO
Can expanded water be accommodated in the
pipework without hot water entering any supply
pipe to which a cold water draw-off is connected?
(If there are any valves preventing reverse flow, select “No”).
YES
NO
Aquaheat:
Use ALK04
Aquaheat:
Use ALK05
Aqualine:
Use ALK01
Aqualine:
Use ALK02
No kit is required
ALK03/ALK07 –
Typical Installation
Outlet taps
Hot outlet
Blended water
to outlets
ALK03/07
Blending
Valve
Cold water in
Water
Heater
Balanced cold
water supply
E-MAIL: [email protected]
Unvented Water Heaters
Kit Selection Chart
29
Aquaheat
Accessories
Unvented Water Heaters
ALK03 TMV2 Thermostatic blending valve.
Suitable for general purpose applications, the blending valve
allows water to be stored at high temperature and then blended
with cold water to deliver a preset outlet temperature. Non-return
valves prevent cross-contamination. Operating pressure 0.2 bar to
6.0 bar. Other benefits include extended system capacity, precise
control of outlet temperature (range 35°C – 60°C) and a lockable
control knob.
ALK07 – TMV3 Thermostatic blending valve.
The TMV3 approved blending valve allows water to be stored at
high temperature and then blended with cold water to deliver a
preset outlet temperature. Non-return valves prevent crosscontamination. Operating pressure 0.2 bar to 5.0 bar. Other
benefits include extended system capacity, precise control of
outlet temperature (range 38°C – 46°C) and a unique adjuster key
to prevent unauthorised temperature adjustment.
Connections
•15mm compression.
30
ALK04 – Expansion vessel, pressure reducer/
strainer and non-return valve.
For all situations where the mains pressure is greater than 4.1 bar.
The pressure reducing valve reduces incoming pressure to 3.5 bar
while the strainer filters coarse impurities from the incoming water.
The non-return valve prevents back-flow of hot water which could
cause cross-contamination of the inlet water. The pressure
reducing valve must be installed on the mains side of the
expansion vessel. For balanced hot/cold water supplies, the pack
should be fitted on the mains side of the cold water draw off; this
is particularly important where mixers are used.
Connections
•Pressure reducing valve ½" BSP female.
•Expansion vessel ½" BSP male.
•Non-return valve 15mm x 15mm compression.
ALK05 – Expansion vessel and non-return valve.
For Aquaheat heaters where expanded water cannot be
accommodated in the pipework and where the mains pressure is
guaranteed never to exceed 4.1 bar. The expansion vessel, when
fully charged, will absorb all expanded water produced by the
Aquaheat heater. Supplied pre-charged to 4.1 bar. The non-return
valve prevents back-flow of hot water which could cause crosscontamination of the inlet water.
Connections
• Expansion vessel ½" BSP male.
• Non-return valve 15mm x 15mm compression.
ALK06 – Pressure and temperature relief valve.
For on-site fitting to Aquaheat heaters. Recommended by Santon
to give an added level of safety. Preset to open at 7 bar and 90ºC.
ALK06 is connected to the outlet of the heater.
Connections
• Drain ½" BSP female.
• Inlet and Outlet 15mm compression.
SPECIFICATION ADVICE: 01603 420128
Aqualine
A full range of accessories is available for installation with Aqualine
unvented water heaters. These are supplied as ‘accessory kits’ to suit
different applications. When installing small unvented water heaters, it
is essential that the correct accessory kits are used. A knowledge of the
maximum incoming water pressure is an essential requirement; where
this is not known, the local water authority should be consulted.
ALK01 – Expansion vessel, expansion relief
valve, pressure reducer/strainer and non-return
valve.
For all situations where the mains pressure is greater than 4.1 bar.
The pressure reducing valve reduces incoming pressure to 3.5 bar
while the strainer filters coarse impurities from the incoming water.
The expansion valve acts as a back-up to the expansion vessel,
opening at 6 bar. The non-return valve prevents back-flow of hot
water which could cause cross-contamination of the inlet water.
The pressure reducing valve must be installed on the mains side
of the expansion vessel. For balanced hot/cold water supplies,
the pack should be fitted on the mains side of the cold water
draw off; this is particularly important where mixers are used.
Connections
•Pressure reducing valve ½" BSP female.
•Expansion vessel ½" BSP male.
•Expansion relief valve inlet ½" BSP male, discharge ½" BSP
female.
•Non-return valve 15mm x 15mm compression.
ALK02 – Expansion vessel, expansion relief
valve, and non-return valve.
For heaters where expanded water cannot be accommodated in
the pipework and where the mains pressure is guaranteed never
to exceed 4.1 bar. The expansion vessel, when fully charged, will
absorb all expanded water produced by the heater. Supplied precharged to 4.1 bar. The expansion valve acts as a back-up to the
expansion vessel, opening at 6 bar. The non-return valve prevents
back-flow of hot water which could cause cross-contamination of
the inlet water.
Connections
•Expansion vessel ½" BSP male.
•Expansion relief valve inlet ½" BSP male, discharge ½" BSP
female.
•Non-return valve 15mm x 15mm compression.
Ordering Guide – Aquaheat
Model Ref.
ALK03
ALK07
ALK04
Product Code
94 970 010
94 970 037
94 970 011
Model Ref.
ALK05
ALK06
Product Code
94 970 012
94 970 013
Ordering Guide – Aqualine
Model Ref.
Product Code
ALK01
ALK02
94 970 008
94 970 009
E-MAIL: [email protected]
Unvented Water Heaters
Accessories
31
Aquaheat
Unvented Water Heaters
Technical Specification
32
Dimensions
Model
AH7/2.2
AH10/2.2
AH15/2.2
A
B
C
Weights(kg)
(mm)(mm)(mm) Empty
Full
356240240 4.9
11.9
442240240 5.9
15.9
417330330 10.0
25.0
Ordering Guide
Model Ref. Product Code Ltrs
Rating
AH7/2.2
94 050 001
7
AH10/2.2
94 050 002
10
AH15/2.2
94 050 003
15
2.2kW @ 240V (2.0kW @ 230V)
single phase AC
2.2kW @ 240V (2.0kW @ 230V)
single phase AC
2.2kW @ 240V (2.0kW @ 230V)
single phase AC
SPECIFICATION ADVICE: 01603 420128
Aquaheat
Specification
Installation
Element
Alloy sheathed element, incorporated into
an easily removable heater plate, should
replacement be necessary.
Inner Container
Heavy gauge copper suitable for a
maximum working pressure of 6 bar
(pressure tested to 15 bar). A minimum
supply pressure of 1 bar is recommended.
Outer Casing
The main body is substantial gauge sheet
steel, anti-corrosion treated, and finished
in white stoved enamel. End covers are
moulded in grey ABS. The back has three
fixing points for wall mounting.
Insulation
Approved CFC/HCFC free (ODP zero)
polyurethane foam. GWP 2.72 (Global
Warming Potential)
Safety Feature
IPX4 rated.
Expansion Relief Valve
This is supplied with the heater and
MUST be fitted with every installation.
It is set at 6 bar. A temperature and
pressure relief valve can be used (order
ref. ALK06).
Expansion/Pressure Kits
If the inlet water pressure is above
4.1 bar, it is essential that kit ALK04 is
also installed with the heater. This kit
comprises expansion vessel, non-return
valve and pressure reducer/strainer.
If the inlet pressure is guaranteed to be
below 4.1 bar where full expansion back
down the mains is not possible, kit ALK05
must be installed (comprises expansion
vessel and non-return valve).
Thermostat
Rod type, adjustable 10°C – 70°C with
integral, manually re-settable, over
temperature cut-out.
Plumbing Connections
Inlet and outlet are 15mm copper tails.
An expansion relief valve is supplied
with the unit and must be fitted to every
installation. The relief valve discharge
pipe must be connected to waste (drain)
via a tundish. The drain pipe from the
tundish must fall continuously and be
22mm diameter copper pipe. It must
discharge in a visible and safe place.
The pipe must not be reduced in bore
or blocked under any circumstances
and should be protected from frost.
Under no circumstances must hot
water or expanded water be allowed to
contaminate the supply to a cold water
draw off.
Electrical
This unit is supplied with 1 metre of 3
core cable fitted. The installation must
comply with BS 7671 ‘Requirements
for electrical installations’ (IEE Wiring
Regulations). It must be fully earthed and
permanently connected to the electrical
supply through a double pole linked
isolating switch with minimum breaking
capacity suitable for the loading.
Approvals
BEAB approved. CE marked.
Manufactured in the UK in a BS EN ISO
9001:2008, ISO 14001:2004 and BS
OHSAS 18001:2007 registered factory.
Guarantee
Two years product guarantee, from
date of purchase, with on-site service
support. Full details are contained in the
Installation Instructions supplied with
each unit.
E-MAIL: [email protected]
Unvented Water Heaters
Technical Specification
33
Aqualine
Unvented Water Heaters
Technical Specification
34
Dimensions
Model
AL07/3
AL10/3
AL15/3
AL15/4.5
A
(mm)
B
(mm)
456
542
517
517
240
240
330
330
C
Weights (kg)
(mm) EmptyFull
240
240
330
330
6.513.5
7.517.5
11.626.6
11.626.6
Ordering Guide
Model Ref. Product Code Ltrs
Rating
AL07/3
94 050 012
7
AL10/3
94 050 013
10
AL15/3
94 050 014
15
AL15/4.5
94 050 015
15
3.0kW @ 240V (2.8kW @ 230V)
single phase AC
3.0kW @ 240V (2.8kW @ 230V)
single phase AC
3.0kW @ 240V (2.8kW @ 230V)
single phase AC
4.5kW @ 240V (4.1kW @ 230V)
single phase AC
SPECIFICATION ADVICE: 01603 420128
Aqualine
Specification
Installation
Element
Alloy sheathed element, incorporated into
an easily removable heater plate, should
replacement be necessary.
Inner Container
Heavy gauge copper suitable for a
maximum working pressure of 6 bar
(pressure tested to 15 bar). A minimum
supply pressure of 1 bar recommended.
Outer Casing
The main body is substantial gauge sheet
steel, anti-corrosion treated, and finished
in white stoved enamel. End covers are
moulded in grey ABS. The back has three
fixing points for wall mounting.
Insulation
Approved CFC/HCFC free (ODP zero)
polyurethane foam. GWP 2.72 (Global
Warming Potential).
Safety Feature
IPX4 rated.
TMV2 Thermostatic Blending Valve
Precise control of outlet temperature
(range 35°C – 60°C) and lockable
control knob.
Temperature stability ±2°C.
Expansion/Pressure Kits
If the inlet water pressure is in excess of
4.1 bar, it is essential that the Santon
unvented kit ALK01 is also installed with
the heater. This kit comprises expansion
vessel, expansion relief valve, non-return
valve and pressure reducer/strainer.
In instances where the water pressure
is below 4.1 bar, but expansion cannot
occur back down the mains, kit ALK02
must be used (comprises expansion
vessel, expansion relief valve and
non-return valve).
Pressure and Temperature
Relief Valve
This is factory-fitted to the unit, accessible
beneath the removable access cover and
is set at 7 bar/90°C.
Thermostat
Rod type, adjustable 10°C – 70°C with
integral manually re-settable, over
temperature cut-out.
Plumbing Connections
Inlet and outlet are 15mm copper tails.
The factory-fitted temperature and
pressure relief valve discharge pipe must
be connected to waste (drain) via the
tundish supplied. The drain pipe from
the tundish must fall continuously and
be 22mm diameter copper pipe. It must
discharge in a visible and safe place. The
pipe must not be reduced in bore or
blocked under any circumstances and
should be protected from frost.
Electrical
This unit is supplied with 1 metre of 3
core cable fitted. The installation must
comply with BS 7671 ‘Requirements
for electrical installations’ (IEE Wiring
Regulations). It must be fully earthed and
permanently connected to the electrical
supply through a double pole linked
isolating switch with minimum breaking
capacity suitable for the loading.
Approvals
Nemko approved. CE marked.
Manufactured in the UK in a BS EN ISO
9001:2008, ISO 14001:2004 and BS
OHSAS 18001:2007 registered factory.
Guarantee
Two years product guarantee, from date
of purchase, with on-site service support.
Full details are contained in the Installation
Instructions supplied with each unit.
E-MAIL: [email protected]
Unvented Water Heaters
Technical Specification
35
Aquaheat SS
Unvented Water Heaters
Commercial Unvented Water Heaters – Horizontal and Vertical
The range of Aquaheat SS unvented horizontal and vertical water
heaters are available in 50 to 100 litre capacities. Whilst the
attractive, modern design makes the Santon water heaters perfect
for wall mounting, they are also able to be mounted within air
conditioning ceiling voids. With no sacrificial anode necessary there
is no need for regular maintenance checks or costly replacements.
The superior heat loss characteristics and resultant energy efficiency
perfectly demonstrates Santon’s commitment to providing
performance and value for money.
Using only high grade Duplex stainless steel the cylinders are
manufactured in our own factory in the United Kingdom. Fully tested
to meet stringent UK and European safety standards, these low
maintenance, high performance heaters are supplied with a 10 year
cylinder warranty with on-site service support.
36
Aquaheat SS units are supplied with an expansion vessel, temperature
gauge and cold water control kit ensuring the Santon reputation for
supplying safe, quality products is maintained.
SPECIFICATION ADVICE: 01603 420128
Aquaheat SS
Unvented Water Heaters
Commercial Unvented Water Heaters – Horizontal and Vertical
37
Commercial Unvented
Selection Guide
Capacity of Water Heater
50 litres 80 litres
100 litres
Number
of Basins
4–5
5–8
8 – 10
Note: These figures are for guidance only
and local conditions should be taken into
account when sizing the installation.
For full details contact our Specification Advice Hotline on 01603 420128
or fax 01603 420229.
E-MAIL: [email protected]
Aquaheat SS
Technical specification
Unvented Water Heaters
Vertical
A
A
D
E
B
C
D
E
B
C
Horizontal
38
B
B
D
E
C
A
D
E
C
A
Dimensions
Model
A
B
C
D
E
Weights (kg)
(mm) (mm)(mm) (mm)(mm) EmptyFull
H50
H80
H100
V50
V80
V100
700 451472 237100
958 451472 237100
1146451472 237100
700 451472 103100
958 451472 103100
1146451472 103100
18 68
24104
30130
18 68
24104
30130
Ordering Guide
Model Ref. Product Code Ltrs
H50
H80
H100
V50
V80
V100
94
94
94
94
94
94
050
050
050
050
050
050
047
049
051
053
055
057
50
80
100
50
80
100
Rating
3kW
3kW
3kW
3kW
3kW
3kW
@
@
@
@
@
@
240V
240V
240V
240V
240V
240V
(2.8kW
(2.8kW
(2.8kW
(2.8kW
(2.8kW
(2.8kW
SPECIFICATION ADVICE: 01603 420128
@
@
@
@
@
@
230V)
230V)
230V)
230V)
230V)
230V)
Aquaheat SS
Technical specification
Element
Long life Incoloy 825 element and plate.
Inner Container
Duplex stainless steel suitable for a
maximum working pressure of 10 bar
(pressure tested to 16 bar).
A minimum supply pressure of 1 bar
recommended.
Outer casing
White painted steel, stove enamelled
corrosion resistant.
Thermal Insulation
CFC/HCFC-free (ODP zero) flame
retardant expanded polyurethane. 38mm
thickness. GWP 3.1 (Global warming
potential).
Thermostat
Electromechanical capillary type
adjustable from 10ºC to 70ºC.
Safety Features
All models:
Factory-fitted temperature and pressure
relief valve set at 90ºC and 10 bar.
Pressure reducing valve at 3.5 bar.
Non return valve.
Pressure relief valve at 6 bar.
Expansion vessel.
Over-temperature capillary cut-out set
at 85ºC.
All units pressure tested to 15 bar.
IPX4 rated.
Anode
None required.
Installation
Unvented units over 15 litre capacity
must be installed by a competent installer
in accordance with Local Regulations:
England and Wales – Building Regulations
G3.
Scotland – Technical Standards P3.
N. Ireland – Building Regulations P5.
Fixings
Horizontally or vertically wall-mounted
with brackets provided.
Plumbing Connections
22mm compression fittings / ¾" BSP
male connections.
Inlet and outlet are 22mm copper tails.
An expansion relief valve is supplied
with the unit and must be fitted to every
installation. The relief valve discharge pipe
must be connected to waste (drain) via a
tundish. The drain pipe from the tundish
must fall continuously and be 22mm
diameter copper pipe. It must discharge
in a visible and safe place. The pipe
must not be reduced in bore or blocked
under any circumstances and should be
protected from frost.
Under no circumstances must hot
water or expanded water be allowed to
contaminate the supply to a cold water
draw off.
Temperature and Pressure Relief Valve
22mm compression outlet.
Cold Water Control
Integrated cold water control set
comprising pressure reducing valve and
strainer – factory-set 3.5 bar, expansion
relief valve – factory-set at 6 bar and
check valve.
22mm compression fittings.
Tundish (supplied as part of kit). Mains
pressure; minimum 1 bar, maximum
16 bar.
Rating
240V AC, 50/60Hz
Electrical
The installation must comply with
BS 7671 ‘Requirements for electrical
installations’ (IEE Wiring regulations).
It must be fully earthed and permanently
connected to the electrical supply
through a double pole linked isolating
switch with minimum breaking capacity
suitable for the loading.
Optional Accessories
TMV2 (ALK03) and TMV3 (ALK07)
thermostatic blending valves may also
be used in conjunction with the Aquaheat
SS (see page 30).
Approvals
Nemko and Kiwa approved.
CE marked.
Manufactured in the UK in a BS EN ISO
9001:2008, ISO 14001:2004 and BS
OHSAS 18001:2007 registered factory.
Guarantee
The Aquaheat SS duplex stainless steel
cylinder carries a full 10 year on-site
parts and labour. All other components
carry a 2 year guarantee. Full details are
contained in the Installation Instructions
supplied with each unit.
E-MAIL: [email protected]
Unvented Water Heaters
Specification
39
Aquarius
Vented Water Heaters
Sink and Basin Supply 10 Litres and Under
40
As small vented water heaters are typically installed directly over or
under the sink, this range of products is commonly referred to as
“Point of Use”. The majority of units are installed directly over or
adjacent to the point of application for light commercial duty such as
washing cups and dishes. They can be supplied either directly from
the mains or from an elevated cistern or feed tank (a minimum head
pressure of 4 metres is required).
Aquarius Vented Oversink
An oversink unit is supplied with an inlet valve that, when opened, allows
the mains cold water supply to enter the heater and displace the hot water
stored in the cylinder. As the valve controls the displacement, the outlet is
open to atmosphere so that when the unit heats up, the expanded water
is allowed to drip from the spout into the basin. No other outlet should be
used in conjunction with this type of product.
Aquarius oversink products are available in 7 and 10 litre capacities with
options for 3.0kW and 1.2kW element ratings. Typically, they are supplied
from the water mains although supply from a cistern can be used as long as
there is a minimum head pressure of 4 metres.
The 3.0kW element provides a fast recovery from cold whereas the 1.2kW
version means that Aquarius can be fitted in situations where the power
supply may be limited, such as portable or temporary buildings.
SPECIFICATION ADVICE: 01603 420128
Aquarius
Sink and Basin Supply 10 Litres and Under
Aquarius Vented Undersink
Undersink models can also be connected to a cold water cistern or feed tank
as long as the vented tap is used or a vent pipe is plumbed from the hot
pipework to discharge the expansion back into the cistern. In such cases, the
base of the cistern must be no higher than 10 metres above the top of the
water heater and a vent pipe must be used.
Vented Water Heaters
These can also be fed from the mains but only if one of the self venting taps
(see pages 44-45) is used. As with the oversink model, the special tap
acts as an inlet valve so that when the tap is turned on, the cold supply is
allowed to flow through the water heater, displacing the hot water into the
basin. The outlet part of the tap is always open to atmosphere allowing the
expanded water to drip from the tap into the basin during the heat up cycle.
Undersink vented water heaters are only able to supply one basin when used
with vented taps. Aquarius undersink products are available in 7 and 10 litre
capacities with options for 3.0kW and 1.2kW element ratings.
41
The 3.0kW element provides a fast recovery from cold whereas the 1.2kW
version means that Aquarius can be fitted in situations where the power
supply may be limited, such as portable or temporary buildings.
E-MAIL: [email protected]
Aquarius
Technical Specification
Undersink
Vented Water Heaters
Oversink
42
Dimensions
Oversink
A7/3
A7/1
A10/3
A
(mm)
B
(mm)
C
Weights (kg)
(mm) EmptyFull
356
356
442
240
240
240
240
240
240
4.911.9
4.911.9
5.915.9
356
356
442
240
240
240
240
240
240
4.911.9
4.911.9
5.915.9
Undersink
AU7/3
AU7/1
AU10/3
Ordering Guide
Oversink
Product Code Ltrs
A7/3
94 010 001
7
A7/1
94 010 002
7
A10/3
94 010 003
10
Rating
3.0kW @ 240V (2.8kW @ 230V)
single phase AC
1.2kW @ 240V (1.2kW @ 230V)
single phase AC
3.0kW @ 240V (2.8kW @ 230V)
single phase AC
Undersink
AU7/3
94 010 008
7
AU7/1
94 010 009
7
AU10/3
94 010 010
10
3.0kW @ 240V (2.8kW @ 230V)
single phase AC
1.2kW @ 240V (1.2kW @ 230V)
single phase AC
3.0kW @ 240V (2.8kW @ 230V)
single phase AC
SPECIFICATION ADVICE: 01603 420128
Aquarius
Technical Specification
Element
Copper sheathed Element, incorporated
into an easily removable heater plate,
should replacement be necessary.
Inner Container
Pressure tested to 1.38 bar (20psi).
A minimum head pressure of
three metres is required.
Outer Casing
The main body is substantial gauge sheet
steel, anti-corrosion treated and finished
in white stoved enamel. End covers are
moulded in grey ABS. The back has three
fixing points for wall mounting.
Insulation
Approved CFC/HCFC free (ODP zero)
polyurethane foam. GWP 2.72 (Global
Warming Potential).
Safety Feature
IPX4 rated.
Thermostat
Capillary type, adjustable 10°C – 70°C.
Safety Cut-out
Models are available with a thermal
fuse cut-out fitted in series with the
adjustable thermostat.
Swivel Outlet – Oversink
Stainless steel tube 300mm, with 15mm
push-fit connection. No other pipework
or spout or tap should be connected to
the outlet.
Inlet – Oversink
An inlet valve is supplied with 15mm
compression connections.
Connections – Undersink
15mm Copper tails.
Electrical
The installation must comply with
BS 7671 ‘Requirements for electrical
installations’ (IEE Wiring Regulations).
It must be fully earthed and permanently
connected to the electrical supply
through a double pole linked isolating
switch with minimum breaking capacity
suitable for the loading.
Approvals
BEAB and Kiwa approved. CE marked.
Manufactured in the UK in a BS EN ISO
9001:2008, ISO 14001:2004 and BS
OHSAS 18001:2007 registered factory.
Guarantee
Two years product guarantee, from
date of purchase, with on-site service
support. Full details are contained in the
Installation Instructions supplied with
each unit.
E-MAIL: [email protected]
Vented Water Heaters
Specification
43
Aquarius
Vented Water Heaters
Vented Taps
The Santon range of taps has been chosen to complement the
Aquarius range of water heaters. It consists of vented hot taps and
matching cold taps for use with vented undersink water heaters,
as well as standard taps which can be used with any other Santon
storage unit. The taps are robust and made in traditional cast brass
with a chrome finish.
A typical installation of an
Aquarius Vented Undersink
heater using a vented tap.
44
Vented Basin Hot Tap – TXH01
40
Compression
fittings
15mm
O/D pipe
168
50
82
69
87
1/2" BSP
(backnut
& washer
supplied)
This tap is constructed to control the flow of incoming mains water supply
to an open outlet type electric water heater. This displaces the heated water
in an unrestricted flow through the tap’s permanently open outlet. This
vented hot tap is for full bore plumbing. Above the basin it is identical to the
universal taps, so a matching cold tap is available if required.
Vented Pillar Hot Tap – TXH02
151
168
Compression
fittings
15mm
O/D pipe
50
1/2" BSP
(backnut
& washer
supplied)
This is a pillar
(or high neck) tap
version of model
TXH01.
82
130
90
SPECIFICATION ADVICE: 01603 420128
Aquarius
Vented Taps
69
90
119
87
1/2" BSP (backnut
& washer supplied)
These taps are packed individually with both a red and blue bezel and are
normally used in cold tap form to match the TXH01.
Ref. TXU02: Order Code 94 970 018
This is a pillar (or high neck) tap version of model TXU01 to match TXH02.
Vented Mixer Tap – TXM01
50
180
Compression
fittings 15mm
O/D pipe
168
50
1/2" BSP
(backnut &
washer supplied)
82
73
This is similar in operation
to the vented hot tap
but has the additional
advantages of mixing the
heated and cold water at
the outlet and is ideally
suited to kitchen use.
140
180
Ordering Guide
Model Ref.
TXH01
TXH02
TXU01
TXM01
Product Code
94
94
94
94
970
970
970
970
E-MAIL: [email protected]
014
015
017
016
Vented Water Heaters
Universal Basin Tap – TXU01
45
EV 2008
Hand Hygiene
Efficient and Economical Handwashing
Electric handwash units offer many benefits when compared to
traditional methods of supplying hot water in the washroom. They
are more economical to run, as the water is heated instantaneously
at the point of use, and therefore provide an energy efficient source
of hot water for handwashing. Compact in size, they can be installed
in a wide range of locations to provide hand wash facilities ensuring
compliance with current Health and Safety legislation.
The Santon EV 2008 range is cost effective, with stylish design and
excellent performance. Designed to supply heated water to one basin
by means of a swivel spray outlet, the units are ideal for commercial
use when control of the water flow is required. The range includes
an instantaneous no-touch unit for hygienic means of providing hot
water for hand washing.
46
SPECIFICATION ADVICE: 01603 420128
EV 2008
Features and Benefits
Performance
• S
ummer / Winter performance – good flow rates even with low inlet
water temperature.
• Flow / temperature stabilised – for consistent outlet temperature.
Installation
• 15mm female push-fit plumbing connection – for ease of installation.
Hand Hygiene
• E nergy efficient – located at point of use, eliminating long pipe runs,
­­­­and heats water on demand.
• C
oncealed connections – option for water and electrical supply to be
made from rear of unit for neater, tidier installation.
Design
47
• 'Power-On' indicator.
• S
limline design – compact footprint requires only small amount of
wall space.
• Attractive styling – fits in with today’s work environment.
• L ow velocity spray plate – gives consistent spray pattern over wide range
of flow rates for efficient handwashing without splashing.
• 200mm stainless steel swivel spout – for durability and quality appearance.
• Retro fit to previous model for ease of installation.
• N
o-touch control dial for on/off, temperature/flow setting via a tamperproof adjuster (No Touch models).
Safety Controls
• Pre-set safety cut-out – prevents overheating.
• P
ressure relief device – prevents high pressure build-up should handwash
unit become blocked or frozen.
• T
emperature stabiliser – ensures that the temperature of the water is
maintained across the range of water pressures.
E-MAIL: [email protected]
EV 2008
Technical Specification
EV 2008
Hand Hygiene
B
C
A
D
48
EV 2008 No Touch
B
C
A
D
Dimensions
Model
A BC D
(mm)(mm)(mm)(mm)
EV 2008 36915198 240
EV 2008 NT369 151 87 240
Ordering Guide
Model Ref.
Product Code
EV 2008/3
94 020 015
EV 2008 NT 94 020 017
Rating
3.1kW @ 240V (2.9kW @ 230V)
single phase AC
3.1kW @ 240V (2.9kW @ 230V)
single phase AC
SPECIFICATION ADVICE: 01603 420128
EV 2008
Specification
Installation
Controls
Combined On/Off and temperature
control knob with large finger/thumb grip
for ease of use. No touch controls – Easy
to use No Touch on-off dial.
Casing
The unit is splashproof and is encased
in a white moulded HIPS (High Impact
Polystyrene) plastic cover which conceals
both the plumbing and electrical
connections.
Inner Container
Copper cylinder complete with Inlet and
Outlet connections, pressure relief device
and heating element.
Element
Copper sheathed rod-type.
Pressure Relief
A pressure relief device is incorporated in
the base of the container to prevent high
pressure build-up if the handwash unit
should become blocked or frozen.
High Temperature Cut-out
A pre-set safety cut-out set at 52ºC
prevents overheating should abnormal
conditions arise – this will re-set at 42ºC.
In addition there is a failsafe, second stage
protection, which is not resettable and
cuts out at 92ºC.
Temperature Stabiliser
An automatic temperature stabiliser ensures
that the temperature of the water is
maintained across the water pressure range.
Pressure Range
Min: 1 bar. Max: 7 bar.
Connections
15mm female push-fit connection at base
of unit for bottom or rear (concealed)
connection.
Outlet
Stainless steel swivel spout with spray
outlet (200mm).
Spray Plate
Low velocity spray giving consistent spray
pattern, for efficient handwashing, over a
range of flow rates.
Fixing
Base plate is secured to wall by two
fixing screws, after which electrical and
plumbing connections are made.
Spout and front cover are then attached.
Two screws secure the front cover.
Electrical
Special requirements of the IEE wiring
regulations should be observed when
installing in bathrooms. Units must be
permanently connected to the electrical
supply through a double pole linked
isolating switch.
Can be supplied from a ring final circuit
via fused spur with a double pole linked
isolating switch with a 13A minimum
breaking capacity. Cable: 1.5 – 2.5mm².
Approvals
BEAB and Kiwa approved.
Guarantee
Two years product guarantee, from
date of purchase, with on-site service
support. Full details are contained in the
Installation Instructions supplied with
each unit.
E-MAIL: [email protected]
Hand Hygiene
Technical Specification
49
Speediboil
Drinking Water
Boiling Water ‘On Tap’
Santon is one of the leading brands in the UK for water heating.
For commercial applications, boiling water heaters have a number
of advantages over traditional methods. For example, one of our
smallest 2.5 litre units can supply over 150 cups of boiling water in
one hour. The time saved in constantly boiling kettles to make drinks
is vastly reduced, and the time spent waiting for a kettle to boil is
removed completely. The Speediboil provides instant hot water.
50
Features and Benefits
Performance
Installation
Speediboil provides a cost effective
solution for a variety of commercial
applications including canteens,
offices, workshops, hairdressers and
waiting rooms.
Ease of installation has long been
a trademark of Santon products
and this range is no exception.
Full fitting instructions and easily
accessible plumbing fittings provide
a quick and easy solution.
SPECIFICATION ADVICE: 01603 420128
A
Speediboil
B
F
D
E
Boiling Water ‘On Tap’
250mm approx
Worktop
Drinking Water
B
30
A
F
D
E
250mm approx
G
C
Worktop
Dimensions
Capacity A
B
C
D
E
F
G Weight full
(mm)(mm)(mm)(mm)(mm)(mm)(mm)
(kg)
2.5 litres445290190 80 115 101 152
5.0 litres510335200103133101163
30
7.5 litres510335262103133101225
8.4
11.8
15.4
Ordering Guide
Model Ref.
Speediboil
Speediboil
Speediboil
G
Product
C
Code
94 200 001
94 200 002
94 200 003
Capacity
2.5 litres
5.0 litres
7.5 litres
Specification
Ratings
2.5kW @ 240V, all capacities.
Outer Casing
White ABS moulding.
Thermal Insulation
CFC/HCFC free (ODP zero) pre-moulded
polystyrene and thermoplastic blend.
Water Container
Moulded thermoplastic. Removable steam
condensation chamber for maintenance
access.
Heat Unit
Low watts density Superloy element for
long life.
Thermostat
Electronic to control water temperature
up to boiling point.
Safety Features
All models are low-pressure vented. Dry
start protection by self re-setting bi-metal
thermal cut-out. Boil dry protection by
manually resettable disc-type bi-metal
cut-out. IPX2 rated.
Plumbing
Cold water feed should be taken directly
from the mains – min pressure
0.5 bar (7psi), max pressure 10 bar
(145psi). Bottom or rear entry using
15mm push-fit connections.
Electrical
Supply (bottom or rear entry) can be
taken from a suitable ring final circuit
via a fused spur but must be via a
double-pole linked isolating switch with
a minimum break capacity of 13A. All
electrical work must comply with the
latest IEE wiring regulations.
Approvals
BEAB approved. CE marked.
Manufactured in the UK in a BS EN ISO
9001:2008, ISO 14001:2004 and
BS OHSAS 18001:2007 registered factory.
Guarantee
Two years product guarantee from date
of purchase with on-site service support.
Full details are contained in the Installation
Instructions supplied with each unit.
Installation
Speediboil units have hook-on brackets
for wall mounting, ideally over a draining
board or drip-tray. 150mm clearance
should be allowed around the unit for
maintenance (refer to instructions).
E-MAIL: [email protected]
51
PowerPack
Instantaneous Water Heating
Instantaneous Water Heater
PowerPack is a compact instantaneous water heater. It can supply
more than one outlet or spray tap, provided only one outlet tap is
used at one time. PowerPack is ideally suited to supplying heated
water to a remote area, such as a garage or cloakroom. It can be
concealed from view and thus be protected from vandalism.
52
• Available in 7kW and 9kW models.
• Ideal for supplying hot water for
bedsits, student accommodation
and to remote areas.
• W
hite moulded vandal resistant
ABS casing.
• H
igh temperature cut-out
for safety.
SPECIFICATION ADVICE: 01603 420128
PowerPack
C
D
B
A
Dimensions
Model
A BC D
(mm)(mm)(mm)(mm)
PowerPack 31 210160 104
Ordering Guide
Model Ref.
Product Code
Rating
PowerPack
PowerPack
94 050 211
94 050 212
7.0kW @ 240V single phase AC
9.0kW @ 240V single phase AC
Specification
Controls
A pressure differential switch activates the
unit when the water flows.
Casing
Moulded from white ABS.
Inner Container
Glass reinforced plastic cylinder, complete
with inlet/outlet connections and
element. A drain plug is fitted to drain
the container to prevent freezing if left
in winter.
Fittings
A pressure relief valve set to relieve at
10 bar is provided together with a
tee-piece which must be fitted on
the cold water inlet. This valve MUST
be connected to waste (drain) via a
tundish and the drain pipe should fall
continuously and be of 22mm bore
discharging in a safe visible manner.
The pipe must not be reduced in bore or
blocked under any circumstances and it
should be protected from frost.
Safety Feature
IPX1 rated.
Pressure Range
Min: 1 bar.
Max: 7 bar.
Connections
½" BSP inlet and outlet.
Approvals
BEAB and Kiwa approved.
CE marked.
Guarantee
Two years. Full details are contained
within the Installation Instructions
supplied with each unit.
E-MAIL: [email protected]
Instantaneous Water Heating
Technical Specification
53
R Units
Combination Storage
Wall Mounted Combination Storage
R Units are designed to supply hot water for handwashing,
dishwashing and general cleaning purposes to cloakrooms, canteens
and kitchen areas. Supplied with an integral cold water cistern, they
are ideal for installations where the cold feed is from the mains
supply but an unvented installation is impractical.
R Unit Selection Guide
Model Number
of Basins
R25 R45
R70
R115
2
3
4–5
5–7
Note: These figures are for guidance only
and local conditions should be taken into
account when sizing the installation.
54
For full details contact our Specification Advice Hotline on 01603 420128
or fax 01603 420229.
Suitable for direct connection to the mains water supply. These units are
ideal for supplying hot water for multi-outlet applications.
The diagram below refers to a typical installation of an R Unit. The pressure
at the outlet is determined by the height of the water heater – the higher
the unit is mounted above the highest outlet, the greater the pressure.
In no circumstances should the base of the water heater be lower than
any outlet it is supplying.
A typical installation of a Santon R Unit
Overflow
Heater
Basin
Basin
Basin
Basin
Cold water
supply
SPECIFICATION ADVICE: 01603 420128
R Units
Technical Specification
B
Combination Storage
C
A
E
D
55
Dimensions
ModelCapacity A
B
C D
E
Weight(kg)
(Ltrs)
(mm)(mm)(mm)(mm)(mm) Empty Full
R25
R45
R70
R115
25
45
70
115
880452215307680
846610290410647
1055610290410856
1011610445410817
15
21
25
30
45
74
103
153
Ordering Guide
Model Ref.
Product Code
R25
R45
R70
R115
R25
R45
R70
R115
Specification
Element
A 3.0kW alloy sheathed immersion heater
is supplied fitted into the integral 2¼"
BSP boss.
Thermostat
Adjustable from 40°C to 80°C with
integral, manually re-settable, over
temperature cut-out.
Inner Container
Copper rectangular tank. Pressure
tested to 0.14 bar. The cold water feed
tank is built into the top of the outer case
and in the following capacities. R25: 4.5
litres, all other models: 8 litres. Supplied
complete with ball valve and overflow
which can be fitted left or right hand.
Casing
Substantial gauge sheet steel
anti-corrosion treated and finished in
stoved enamel. White body and base.
Insulation
Approved CFC/HCFC free (ODP zero) polyurethane foam. GWP 3.1 (Global
Warming Potential).
Safety Feature
IPX1 rated.
Approvals
BEAB approved. CE marked.
Manufactured in the UK in a BS EN ISO
9001:2008, ISO 14001:2004 and BS
OHSAS 18001:2007 registered factory.
Connections
½" BSP (male) ball valve / ¾" BSP (male)
overflow and hot water outlet.
Guarantee
Two years. Full details are contained
within the Installation Instructions
supplied with each unit.
E-MAIL: [email protected]
Immersion Heaters
Immersion Heaters
Industrial Electrical Water Heaters
56
Santon is a leading manufacturer of industrial immersion heaters.
It supplies elements for use in commercial and industrial
environments covering the heating of water, oil and other solutions.
Whatever the application, Santon is able to provide the answer.
Water
Oils
Santon manufactures a wide range
of immersion heaters for heating
water in commercial and industrial
environments. Two element sheath
materials are supplied to cater for
all water conditions – Superloy and
Titanium. All Industrial Immersion
Heaters are covered by a full 12
month guarantee. These heaters are
supplied with a factory-fitted stem
type thermostat.
Great care needs to be taken when
selecting an immersion heater for
oil and full details on the oil type,
viscosity, etc. should be obtained
from the oil manufacturer. Advice
should be sought as to the most
suitable watts density output rating
permissible with the oil.
A variety of fixing methods cover
all conceivable installations, with
loadings from 2.0kW available on
a 2¼" BSP head, to 54kW available
on a flanged fixing. Applications
can vary from car wash machines to
industrial calorifiers and swimming
pool heaters.
For the majority of applications
the electrical loading per unit
surface area of the immersed
heating element is important and
a special range designed for use in
oil is required. If the correct rating
is not used rapid breakdown of
the immersion heater can occur
with serious consequences to the
industrial process concerned.
When selecting which immersion
heater is required, it is advisable to
use the longest element that will
fit into the vessel being heated.
This ensures that heat dissipation is
maximised and keeps the watts
density of the element to a minimum,
which prolongs element life.
SPECIFICATION ADVICE: 01603 420128
Immersion Heaters
Immersion Heaters
Industrial Electrical Water Heaters
Environments
Custom Built
All Santon heaters are characterised
by their ability to withstand the most
arduous working conditions and
are therefore supplied with terminal
enclosures to suit. In the case of the
‘M’ and ‘L’ ranges, the immersion
heater cover is manufactured in
accordance with IP65. All thermostat
pockets are made from Superloy.
In a number of applications it is not
always possible to fit a standard
immersion heater.
Our technical department can give
expert advice in the specification
and design of a heater to suit
individual requirements. The
following information will help us
to specify the optimum method of
heating the solution:• Type of fluid to be heated.
• Viscosity of fluid (if applicable).
• Size of tank.
• Lowest initial temperature.
• Maximum working temperature.
• M
aximum permissible length of
heater element.
• Type of heater fixing required.
E-MAIL: [email protected]
57
Immersion Heaters
Industrial Electrical Water Heaters / Technical Specification
Immersion Heaters
Water 2¼" BSPT Fixing Complete With Control Thermostat
58
Loading Model Ref.
kW
Superloy
2
3
3
4
4
6
6
6
7.5
9
9
9
12
12
18
MY211
MY311
MY330
MY411
MY416
MY616
MY630
MY642
MY724
MY916
MY927
MY936
MY1224
MY1236
MY1836
Model Ref.
Phases
Titanium -
-
-
-
-
MT616
-
-
MT724
-
MT927
-
-
-
-
Immersed Length
(mm)
(ins) 1 only
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3 1 or 3
1 or 3
1 or 3
3 only
1 or 3
1 or 3
1 or 3
1 or 3
3 only
280
280
760
280
405
405
760
1065
610
405
685
915
610
915
915
11
11
30
11
16
16
30
42
24
16
27
36
24
36
36
Water 2½" BSPT Fixing Complete With Control Thermostat
Loading Model Ref.
kW
Superloy
6
9
12
15
18
LY615
LY920
LY1226
LY1532
LY1838
Model Ref.
Phases
Titanium -
-
-
-
-
Immersed Length
(mm)
(ins) 1 or 3
1 or 3
3 only
3 only
3 only
380
510
660
810
970
15
20
26
32
38
A second pocket is provided to fit a manual reset limit thermostat.
Water Bolt-On Fixing Complete With Control Thermostat
Loading Model Ref.
kW
Superloy
Model Ref.
Phases
Titanium 12
DY1216
DT1216
18
DY1816
-
18-
DT1823
24
DY2416
-
24-
DT2430
24-
DT2436
30
DY3027
-
36
DY3627
-
45
DY4527
-
54
DY5436
-
Immersed Length
(mm)
(ins) 3
3
3
3
3
3
3
3
3
3
40516
40516
58523
40516
76030
915 36
685 27
685 27
685 27
91536
These heaters are for horizontal application only. A second pocket is provided to fit a manual
reset limit thermostat.
Special elements are available for most types of fluids.
Please consult our Specification Advice Hotline on
01603 420128 or fax 01603 420229.
SPECIFICATION ADVICE: 01603 420128
Immersion Heaters
Industrial Electrical Water Heaters / Technical Specification
Loading Model Ref.
kW
Superloy
4.5
6
MGY414
MGY616
Model Ref.
Phases
Titanium -
-
Immersed Length
(mm)
(ins) 1 or 3
1 or 3
355
405
14
16
Oils 2¼" BSPT Fixing Complete With Control Thermostat
Loading
kW
Model Ref. Phases Surface Rating Immersed Length
Steel
(W/cm²) (W/ins²) (mm)
(ins) MO342
MO224
MO336
MO560
MO672
MO112
MO330
MO442
MO548
MO660
3
2
3
5
6
1
3
4
5
6
1 or 3
1 only
1 or 3
1 or 3
1 or 3
1 only
1 or 3
1 or 3
1 or 3
1 or 3
1.4
1.6
1.6
1.6
1.6
1.9
1.9
1.9
1.9
1.9
9
10
10
10
10
12
12
12
12
12
1065
610
915
1525
1830
305
760
1065
1220
1525
42
24
36
60
72
12
30
42
48
60
Note: Heaters with an immersed length over 1.2m (4 feet), require internal support in the
vessel to remove strain from the head fixing.
Oils 2½" BSPT Fixing Complete With Control Thermostat
Loading
kW
Model Ref. Phases Surface Rating Immersed Length
Steel
(W/cm²) (W/ins²) (mm)
(ins) 2
3
6
1
3
5
6
LO224
LO336
LO672
LO112
LO330
LO548
LO660
1 only
1 or 3
1 or 3
1 only
1 or 3
1 or 3
1 or 3
1.6
1.6
1.6
1.9
1.9
1.9
1.9
10
10
10
12
12
12
12
610
915
1830
305
760
1220
1525
24
36
72
12
30
48
60
Note: Heaters with an immersed length over 1.2m (4 feet), require internal support in the
vessel to remove strain from the head fixing.
Flanges
A range of flanges is available to complement Santon immersion heaters.
For MY, MT, MGY and MO type Industrial Immersions 2¼" Universal
mechanical flange – ref. F100U
2¼" Blanking plug – ref. F105.
For DY and DT type Industrial Immersions
Brass flange – ref. F8462.
Thermostats
Contact our Specification Advice Hotline on
01603 420128 or fax 01603 420229.
E-MAIL: [email protected]
Immersion Heaters
Water 2¼" BSPT Fixing Complete With Cut-Out
59
Useful Information
Metric
Useful Information
Conversion Formulae
60
1 litre = 1000 cu. cm.
(61 cu. in.)
1 kg.
0.22 gal.
1.76 pt.
1 kilogram = 2.204lb
cubic metre=
1
verage cold Winter 4/7°C
A
mains water Summer 15/18°C
temperature
1000 litres
35.31 cu. ft.
1.31 cu. yd.
1 metre = 39.37 in.
3.28 ft
1.09 yd.
1 sq. metre = 1550.39 sq. in.
10.763 sq. ft. 1.195 sq. yds.
Water 10% on freezing expansion 4% on heating
due to to 100°C
temperature
Heating and Electrical Data
1 kilowatt hour (kWh)
1 watt (W) 1 kilowatt hour (kWh)
=
=
=
3,412 British thermal units (Btu)
1 joule per second (1 J/s)
860 kilocalories
ne kilocalorie is the amount of heat required to raise 1 litre of water O
through 1°C. 1kWh raises 15.5 litres of water through 56°C.
Water Heating Calculations
kW loading = (litres x temp. rise °C) ÷ (14.3 x time in mins.)
Time in mins. = (litres x temp. rise °C) ÷ (14.3 x kW loading)
Litres = (14.3 x kW loading x time in mins.) ÷ (temp. rise °C)
Temp. rise °C = (14.3 x kW loading x time in mins.) ÷ (litres)
Mean Water Temperature in °C
(Litres hot x temp. hot °C) + (litres cold x temp. cold °C)
Total (hot + cold) litres
Temperature Conversion
°C = (°F – 32) x 0.555
Capacities of Cylinders and Tanks (Litres)
Cylinder
Height x dia. (cm²)
1273
Tank
length x breadth x height (cm)
1000
Oil Heating Calculations
kW loading = litres per hour x temp. rise (°C)
1464
SPECIFICATION ADVICE: 01603 420128
Useful Information
Imperial
1 gallon =
277cu. in.
(4546 cu. cm.)
10 lb (4.533kg.)
4.54 litres.
Average cold Winter 40/45°F
mains water Summer 60/65ºF
temperature
1 cubic foot=
1 inch =
1 foot =
1 yard =
1 sq. yard =
1 pound =
6.23 gal.
0.028 cu. m
25.4 mm
304.8 mm
914.4 mm
0.836 sq.m
0.4536 kg
Water 10% on freezing expansion 4% on heating
due to to 212°F
temperature Useful Information
Conversion Formulae
Heating and Electrical Data
1 kilowatt hour (kWh) = 3,412 British thermal units (Btu)
One British Thermal unit is the amount of heat required to raise 1 lb
of water through 1°F.
1kWh (3,412 Btus) raises 3.41 gallons of water through 100°F
Water Heating Calculations
kW loading = (gallons x temp. rise °F) ÷ (5.7 x time in mins.)
Time in mins. = (gallons x temp. rise °F) ÷ (5.7 x kW loading)
Gallons = (5.7 x kW loading x time in mins.) ÷ (temp. rise °F)
Temp. rise °F = (5.7 x kW loading x time in mins.) ÷ (gallons)
Mean Water Temperature in °C
(Gallons hot x temp. hot °C) + (gallons cold x temp. cold °C)
Total (hot + cold) gallons
Temperature Conversion
°F = (°C x 1.7) x 3.2
Capacities of Cylinders and Tanks (Litres)
Cylinder
Height x dia. (in²)
353
Tank
length x breadth x height (in)
277
Oil Heating Calculations
kW loading = gallons per hour x temp. rise (°F)
580
E-MAIL: [email protected]
61
Useful Information
Recovery Chart
Useful Information
Approximate time in minutes to heat water through 56°C
temperature rise.
62
Litres
Loading in kilowatts
11.21.5 2 3 4 67.5 9121518242730364554
5 20161310 7 5
7 28231814 9 7
10 393326201310
15 59493930201510
23 90756045302315
30 118987859393020
34 133
1118967453423
50 196
163
1319866493326
55
1087254362924
68896745363023
80
1057953423526
86
1128456453728
91
1198959484030
100
1319865524433
114
149
11274605037
115
150
11375605038
120
157
11878635239
136
178
133897159443630
144
188
141947563473831
166
217
163
1088772544336
182
238
178
1199579594840
210274206137110 81 69 55 46
227296222148119 99 74 59 49
364
238
190
158
119
95
79
59
455297238198148119 99 74
550359287239179144120 90 80 72 60 48 40
700366305228183152114102 91 76 61 51
900392294235196147131117 98 78 65
1200392313261196174157131104 87
1800
392
294
261
235
196
157
131
2500
408
363
326
272
218
181
3000
392
326
261
218
Suggested Volumes
Hot water in litres stored at 71ºC per person/bath/shower
Wash basin
Spray taps
Baths
Kitchens
Cleaners sinks
Dishwashing machines
Washing machines
Showers
Hairdressers:
Ladies – per basin per hour
Mens – per basin per hour
Domestic
Commercial
1.1
1.1 to 2.3
-
0.6 to 1.4
5570
3
2.3 to 7
- 9 per day
2
4
20
20 to 60
5 to 9 per min.
9 to 12 per min.
-
-
36
7
SPECIFICATION ADVICE: 01603 420128
Useful Information
Notes
63
E-MAIL: [email protected]
heateam is Santon’s very own service division. With us on your side,
you can be sure that your customers are in the very best hands.
Totally committed to quality and safety, heateam is open 7 days a week,
for 363 days a year, and offers:
• Dedicated Trade Advice Line – our helpful and qualified specialists are
always on hand to help you with even the most complex technical query.
• Installer Priority Call-Outs – our 280 strong team of specifically trained
expert heating engineers covers the UK, no one is better qualified to look
after Santon’s products for the duration of the guarantee.
• Fully Stocked Vans – a nationwide fleet of vans, fully stocked with
spare parts – meaning we can repair our appliances on the first visit
in 95% of call-outs.
• Exclusive Service Plans – heateam also offer Santon’s customers a range
of exclusive annual service plans.
Opening Times: Monday-Friday 8am-6pm, weekends and Bank Holidays*
8.30am-2pm.
*excluding Christmas Day and New Year’s Day.
Simply call 0844 8711535 or visit our website at www.heateam.co.uk
Santon, Hurricane Way, Norwich, Norfolk, NR6 6EA
Specification Advice Hotline
Tel: 01603 420128 Fax: 01603 420229
E-mail: [email protected]
After Sales Service
Tel: 0844 871 1530 Fax: 0844 871 1528
E-mail: [email protected]
Website
www.santon.co.uk
The pace of product development is such that we reserve the right to change product
specifications without notice. We do, however, strive to ensure that all information in this
catalogue is accurate at the time of going to publication.
© Santon July 2012
Issue 5
part no. 94 900 006