Water Heating Catalogue
Transcription
Water Heating Catalogue
CI/SfB (53.3) x July 2012 Water Heating Catalogue Introduction 2 A Leading Name Santon has been a leading name in water heating for over seventy years with a comprehensive product portfolio, which includes vented and unvented water heaters for domestic, commercial and industrial use. Its reputation is built upon manufacturing top quality, highly reliable products, designed to meet the most demanding customer needs. SPECIFICATION ADVICE: 01603 420128 The company uses the latest techniques in research, development and manufacturing to ensure that Santon’s product range satisfies all of its customers’ requirements and represents excellent value for money. Introduction Santon is synonymous with innovation. The new PremierPlus unvented, systemfit and solar cylinder range has brought more stringent levels of temperature control to an increasingly safety conscious commercial environment. 3 Customer Support In today’s demanding market place, a company’s overall reputation is only as good as the quality of its customer support. To ensure the very highest level of customer support, our sales and service hotlines provide direct access to our knowledgeable teams. Our qualified and experienced team of Area Sales Managers are available to visit specifiers and installers nationwide. All Santon products are covered by a minimum two year guarantee. In the unlikely event of a product failure, our service experts will either provide an instant solution over the phone or arrange for a prompt service call from a qualified engineer to quickly remedy the problem. Whether the need is specification, sales, installation or service related, Santon is able to offer the ideal solution. E-MAIL: [email protected] Product Selector Product Selector Hot water for single basin or sink supply (commercial) 4 Type Mounting Vented or Unvented Product Storage Over/UndersinkVented Aquarius Storage UndersinkUnvented Aquaheat InstantaneousOverbasin n/a EV2008 InstantaneousWall Unvented PowerPack Hot water for two or more basins or sinks (commercial) Type Mounting Vented or Unvented Product Storage Floor UnventedPremierPlus Storage UndersinkUnvented Aquaheat or Aqualine InstantaneousWall Unvented PowerPack Storage Wall Vented R Units Storage Ceiling Vented Aquaheat SS or void Hot water for household use (domestic) Type Mounting Storage Storage Storage Vented or Unvented Product Floor UnventedPremierPlus Floor Unvented PremierPlus SystemFit Floor Unvented PremierPlus Solar Immersion heaters Type Water kW MaterialPhasesProduct or oil loading Industrial Water 2 – 54 Superloy/ 1 or 3 MY, MT, Titanium LY, MGY, DY or DT Industrial Oil 1 – 6 Mild steel 1 or 3 MO or LO The pace of product development is such that we reserve the right to change product specifications without notice. We do, however, strive to ensure that all information in this catalogue is accurate at the time of going to publication. Santon wishes to make it clear that it owns all the original designs of the products it manufactures (whether or not listed in this catalogue) and that it will take all necessary legal action, in any part of the world, against any party found to be manufacturing, selling or otherwise dealing with any article that infringes Santon’s copyrights or patents in its products, or any other right of Santon therein. SPECIFICATION ADVICE: 01603 420128 ContentsPage PremierPlus Solar 12 Solar Unvented Water Heating Aquaheat 24 Unvented Electric Water Heating Aqualine25 Product Selector PremierPlus6 Unvented Water Heating Unvented Electric Water Heating Aquaheat SS 36 Unvented Electric Water Heating Aquarius40 Vented Electric Water Heating Taps44 Vented Electric Water Heating EV 2008 / EV 2008 No Touch 46 Hand Hygiene Speediboil50 Drinking Water PowerPack52 Instantaneous Water Heating R Units 54 Combination Storage Immersion Heaters 56 Industrial Data60 Useful Information E-MAIL: [email protected] 5 PremierPlus Unvented Water Heaters Mains Pressure Unvented Water Heating 6 Designed and manufactured in the UK the PremierPlus range of unvented cylinders lead the way in cost effective mains pressure water heating. Built to the highest standards from Duplex stainless steel, the units offer exceptional corrosion resistance and long-life expectancy. Advanced primary coil and cold water controls design gives rapid reheat and good flow rate performance. It provides mains pressure showering and is suitable for use in new-build or refurbishment schemes for domestic and commercial applications. PremierPlus cylinders are available from 100 to 300 litres, in both direct and indirect models with pre-plumbed and solar options. All models have 50mm of CFC/HCFC-free (ODP zero) foam insulation to give improved heat loss and are finished in a stylish and durable white plastic-coated, corrosion-proofed steel casing with grey high impact thermoplastic moulded top and bottom covers. Features and Benefits • Duplex stainless steel for longer life. • Flexible siting of cylinder installation. • C omplete package incorporates safety and hot water controls. • S avings on installation from simplified plumbing and electrical connections. ains pressure hot water for more • M powerful showers and faster filling baths. • E qually suited to new build and refurbishment projects. • Fully indemnified design service. • No cold feed cistern required. • No shower pump required. • No anode to maintain or replace. • Fully factory tested for reliability. • Fast recovery rates. • Safe, economical performance. • No loft pipes to freeze up.* • 3 0 year cylinder guarantee, 5 years on expansion vessel and 2 years on element and all other controls with on-site parts and labour. *Assumes Sealed System Boiler Installation. SPECIFICATION ADVICE: 01603 420128 PremierPlus The Installer-Friendly Unit Following extensive surveys of installers’ preferences, Santon has designed PremierPlus with the installer in mind. All of the plumbing and electrical connections are located to give easy access during installation. Plumbing connections are 22mm compression. Electrical connections are made to an integrated wiring centre which facilitates a neater, trouble-free and simpler installation. Unvented Water Heaters Simple Installation Heat Exchanger – Indirect Units 7 A high efficiency ‘coil-in-coil’ heat exchanger is situated at the base of the unit which ensures that virtually all of the water is heated. This compares with a typical side entry single coil heat exchanger which typically heats only approximately 80% of the water content. The design also ensures that there is rapid reheat when water is used bettering CHeSS* recommended good practice. *CHeSS – Central Heating System Specifications. General information leaflet 59. Typical Installation of an Indirect PremierPlus E-MAIL: [email protected] PremierPlus Accessory Kits Unvented Water Heaters Duplex Stainless Steel Construction 8 This high strength, high quality material ensures an unsurpassed standard of corrosion protection without the need for anodes. Manufactured in the UK to the highest standards in a BS EN ISO 9001:2008, ISO 14001:2004 and BS OHSAS 18001:2007 registered factory, all units are pressure tested to 15 bar. Safety The high strength Duplex stainless steel cylinder is manufactured using stringent quality control procedures and is pressure tested to over 1½ times its maximum operating pressure. All PremierPlus units have fully integrated thermostatic controls and thermal cut-outs for both direct and indirect heating. A higher level of thermal safety is provided by the factory-fitted temperature and pressure relief valve. Cold Water Controls An integrated cold water control set, exclusively designed for the PremierPlus, and comprising of a pressure reducing valve and strainer, expansion relief valve and check valve reduces installation time by incorporating three components into one and gives significant improvements in flow rate across a range of inlet pressures. Guarantee The use of Duplex stainless steel means that the PremierPlus comes with a 30 year on-site parts and labour transferable guarantee for the cylinder. The expansion vessel has a 5 year on-site parts and labour guarantee and all other valves and fittings supplied with the unit are covered for a period of 2 years. SPECIFICATION ADVICE: 01603 420128 PremierPlus Selection and Ordering Guides Property type Direct model PP100E or PP120E Bedsit 1-2 bed with 1 bath/shower PP150E or PP170E 3 bed with 1 bath/shower PP170E or PP210E 4 bed with 1 bath/shower PP210E or PP250E 2-3 bed with 2 baths/showerPP210E or PP250E 4-5 bed with 2 baths/showerPP250E or PP300E 4-5 bed with 3 baths/showerPP300E Light commercial usage PP250E or PP300E Note: All sizings calculated using BS6700 60 ltr hot water per bath 60 ltr hot water per shower 15 ltr hot water per sink 7 ltr hot water per basin Indirect model PP100B or PP120B PP150B PP170B or PP210B PP210B or PP250B PP210B or PP250B PP250B or PP300B PP300B PP250B or PP300B This selection chart is for guidance only. Hot water requirements will vary dependent on bath size, usage patterns, etc. 9 Please contact the Specification Department for further advice. Ordering Guide Product Ltrs ElementCoil Code RatingRating Direct (kW @240V) (kW) PP100E PP120E PP150E PP170E PP210E PP250E PP250E 9kW PP300E PP300E 9kW 94 94 94 94 94 94 94 94 94 050 050 050 050 050 050 050 050 050 318 319 320 321 322 323 326 324 334 100 120 150 170 210 250 250 300 300 1 2 2 2 2 2 3 2 3 x x x x x x x x x 3 3 3 3 3 3 3 3 3 - 94 94 94 94 94 94 94 94 94 050 050 050 050 050 050 050 050 050 327 328 329 330 331 332 347 333 348 100 120 150 170 210 250 250 300 300 1 1 1 1 1 1 2 1 2 x x x x x x x x x 3 3 3 3 3 3 3 3 3 11.8 12.5 16.4 16.0 18.3 20.0 20.0 20.0 20.0 Indirect PP100B PP120B PP150B PP170B PP210B PP250B PP250B 6kW PP300B PP300B 6kW Unvented Water Heaters Selection Guide E-MAIL: [email protected] PremierPlus SystemFit Unvented Water Heaters Pre-plumbed Unvented Water Heating Santon’s unvented PremierPlus cylinder is available in a pre-plumbed format. PremierPlus SystemFit has been designed to significantly reduce installation time whilst still offering mains pressure water heating. Each factory-assembled unit comes pre-plumbed and pre-wired with 230V central heating controls, pump, two 2-port motorised valves, automatic by-pass and balancing valves. This timesaving PremierPlus SystemFit package not only speeds installation but also significantly enhances the quality and integrity of the central heating system thus eliminating costly callbacks. 10 SPECIFICATION ADVICE: 01603 420128 PremierPlus SystemFit Pre-plumbed Unvented Water Heating • Duplex stainless steel cylinder. • 120, 150, 170, 210, 250 and 300 litre models. • Programmable thermostat with timed Domestic Hot Water (DHW) control. • Primary system pressure gauge. • Coil-in-coil heat exchanger. • Cold-water control set. • Remote expansion vessel. • Separate central heating and hot water zones. • No maintenance three speed circulating pump. Unvented Water Heaters Features • Automatic by-pass valve for system efficiency. • Load balancing valve for indirect coil efficiency. • Connections for vented and unvented heating primaries. • Primary system filling loop. • Auto air vent. • Connection for 2nd CH zone on 170 litre and above. • Primary system expansion vessel (supplied loose for on-site fitting). Benefits • Simplified on-site installation. • Up to 70% quicker to install. • Factory assembled for reliability – reduces costly call-backs and delays. • Consistent electrical and plumbing layout – neat, professional finish. • Greater customer satisfaction. • B S EN ISO 9001:2008, ISO 14001:2004 and BS OHSAS 18001:2007 quality assured. • Kiwa and Nemko approved and CE marked. • 30 year on-site parts and labour cylinder guarantee. • 5 year on-site parts and labour expansion vessel and cold water controls guarantee. • 2 year on-site parts and labour guarantee on element and all other controls. E-MAIL: [email protected] 11 PremierPlus Solar Solar Water Heating Solar Unvented Water Heating 12 Climate change is an undeniable fact which has increased the focus on alternative energy sources. Solar energy direct from the sun is a source of energy which, when harnessed, can be converted into heat to generate hot water for the home, whilst at that same time helping to reduce carbon emissions and reduce global warming. PremierPlus Solar has been designed specifically for solar applications. It offers all of the benefits of the standard PremierPlus unvented cylinder to give powerful mains pressure showering and fast filling baths, with the added benefit of lower running costs – as much as 60% less than traditional systems*. Designed for use with a wide range of solar systems available in the UK, PremierPlus Solar is an environmentally friendly and efficient way of providing domestic hot water. Unlike some other ‘twin coil’ cylinders (which simply use heating coils designed for traditional boiler heated cylinders), PremierPlus Solar cylinders have a purpose designed solar heating coil at the base of the cylinder, which ensures maximum heat input and efficiency from the solar energy. Available in a choice of capacities from 170 to 300 litres, with a choice of direct (electric auxiliary heat input) or indirect (gas, oil or electric boiler auxiliary heat input) versions. SPECIFICATION ADVICE: 01603 420128 PremierPlus Solar Solar Unvented Water Heating During the summer months as much as 100% of the energy used by PremierPlus could be solar*. In winter, despite the lower intensity of the Sun’s rays and fewer daylight hours as much as 20% could be solar*. On average throughout the year up to 60% of a dwelling’s hot water requirement can be provided by solar power*. The balance is provided by traditional means; either indirect (via a gas, oil or electric boiler heating a second coil within the cylinder) or direct (via electric immersion heaters in the cylinder). How does PremierPlus Solar work? The Solar cylinder is used in conjunction with solar panels (not supplied) which convert energy collected from the Sun’s rays to heat a water / glycol liquid in its pipe work. This liquid is circulated through a specially designed solar coil in the base of the cylinder where the liquid transfers its heat to the water stored before being pumped back to the solar panel to be re-heated. The design of this coil allows maximum solar gain to be achieved ensuring that the solar system is being used to its full potential. *savings vary depending on type of solar system used, location and usage patterns. E-MAIL: [email protected] Solar Water Heating How much of your water heating energy needs can be provided by solar? 13 PremierPlus Solar Solar Unvented Water Heating Solar Water Heating Which unit to use The choice of capacity for traditional cylinders is based on the hot water requirements of the dwelling. With solar cylinders, there are a number of other factors which need to be taken in to account such as the solar collectors used and where they are sited. Additionally the amount of usable hot water will vary depending on the solar gain available on a given day. For that reason it is important to ensure that the auxiliary heated volume of the cylinder is capable of meeting the dwelling’s hot water demands on days where solar gain will be low, such as during winter months. Our specification team are available to provide cylinder sizing advice on 01603 420128. Potterton Solar 14 The Santon PremierPlus Solar cylinders are perfectly matched with the Potterton Solar systems. • A range of On-roof and In-roof collector packages available. • Reduces CO² emissions and domestic fuel bills. • Easy to fit range of packaged solutions makes it easy for installers to move to solar energy. • National Technical Support and After Sales Service from a single source. For more details call 0844 871 1560 or visit www.potterton.co.uk SPECIFICATION ADVICE: 01603 420128 PremierPlus Solar Unvented System Benefits Features • Duplex stainless steel cylinder for long life. 1 • Choice of direct or indirect auxiliary heat input. 2 • Specially designed solar coil for maximum solar efficiency. • Complete package includes: – Safety and hot water controls. 4 – Remote expansion vessel. • High flow rates for improved hot water delivery. 3 Solar Water Heating • M ains pressure (unvented) hot water for balanced supply to showers and mixers. • Compatible with a wide range of UK solar systems. • Lower running costs and reduced energy bills. • Environmentally friendly – reduced carbon emissions. • Equally suited for New Build or Refurbishment projects. • Fully indemnified design service. • 30 year on-site parts and labour cylinder guarantee. 1 4 2 4 3 E-MAIL: [email protected] 15 PremierPlus Unvented Water Heaters Technical Specification ø550 29 A C 16 81 B D 45º 25º 30º 45º Dimensions Direct A B C D Weights (kg) (mm)(mm)(mm)(mm) Empty Full PP100E PP120E PP150E PP170E PP210E PP250E PP250E 9kW PP300E PP300E 9kW 784306493 906306615 1090 306 800 1216 306 925 1474 306 1184 1726 306 1391 17263061391 20403061715 20403061715 - - - - - - - - - 23 123 25 145 28178 29199 36 246 45 295 45295 55355 55355 Indirect PP100B PP120B PP150B PP170B PP210B PP250B PP250B 6kW PP300B PP300B 6kW 784354493315 906354615315 1090354800315 1216354925315 14743541184315 17263541391315 17263541391315 20403541715315 20403541715315 SPECIFICATION ADVICE: 01603 420128 25 125 27 147 31 181 33 203 41251 50300 50300 60360 60360 PremierPlus Specification Nominal Capacities 100, 120, 150, 170, 210, 250 & 300 litres. Element Alloy sheathed element, incorporated into an easily removable heater plate, should replacement be necessary. Rated 3.0kW @ 240V. Outer Casing White plastic-coated, corrosion-proofed steel with grey high impact thermoplastic moulded top and bottom covers. Thermal Insulation CFC/HCFC free (ODP zero) fire retardant expanded polyurethane. 50mm thickness. GWP 3.1 (Global Warming Potential). Inner Container Duplex stainless steel, pressure tested to 15 bar. Primary Coil 22mm diameter stainless steel. Coil-in-coil design for improved performance. Thermostat Element thermostat adjustable from 10°C to 70°C. Safety Features All Models: Temperature and pressure relief valve, factory set to operate at 10 bar and 90°C. High limit thermostat, factory set at 80°C. Direct Models: Manually-resettable cut-out, set to 80°C. Anode None required. Approvals CE marked. Nemko approved. Kiwa approved to UK water supply regulations. Kiwa approved for Building Regulation G3. Manufactured in the UK in a BS EN ISO 9001:2008, ISO 14001:2004 and BS OHSAS 18001:2007 registered factory. Guarantee On-site parts and labour from date of purchase. Cylinder – 30 years. Expansion vessel – 5 years. Cold Water Control Kit – 5 years. Element and other controls – 2 years. Installation Unvented units over 15 litre capacity must be installed by a competent installer in accordance with Local Regulations: England & Wales – Building Regulation G3. Scotland – Technical Standards P3. N. Ireland – Building Regulation P5. Fixing Feet on bottom moulding for floor mounting. Plumbing Connections Inlet/Outlet. 22mm compression fittings / ¾" BSP parallel thread. Indirect Coil 22mm compression fittings / ¾" BSP parallel thread. Temperature and Pressure Relief Valve 15mm compression outlet. Cold Water Control Integrated cold water control set comprising pressure reducing valve and strainer – factory set at 3.5 bar, expansion relief valve – factory set at 6 bar and check valve. 22mm compression fittings. Tundish (supplied as part of kit) – 15mm compression inlet and 22mm compression outlet. Mains pressure; Min 1 bar, Max 16 bar. A 2-port motorised valve is supplied with Indirect models. Flow Rates Up to 55 litres per minute @ 6 bar pressure. Operating Pressure 3.5 bar. Expansion Relief Valve Pressure 6 bar. Operating Temperature Recommended 60°C. Adjustable from 10°C to 70°C. Water Expansion Remote expansion vessel – 12 litre vessel supplied with 100, 120 and 150 litre models. 18 litre vessel supplied with 170 and 210 litre models. 24 litre vessel supplied with 250 and 300 litre models. Minimum Water Supply Requirements Recommended minimum supply pressure – 1.5 bar/20 l/min flow rate. If there are any doubts about water supply pressure or flow rates, please contact our Specification Advice Team to discuss. Secondary Circulation Via 22 x 22 x 15mm swept tee, which should be fitted to the inlet pipework. A swept tee is available as an optional accessory – part no. 94 970 033. Secondary circulation is not recommended for direct electric units being used on off-peak electricity tariffs. Pressure Testing Units are tested to 15 bar. Compatible Boilers Gas, Electric or Oil fired – open vent or sealed system type, fitted with integral control thermostat and cut-out. Tundish 15mm compression inlet and 22mm compression outlet. Electrical Direct Models: Connection is to the combined thermostat/thermal cut-out housed within the integrated controls housing. The electrical supply must be permanently connected via a double pole linked isolating switch with a minimum break capacity of 13A. Indirect Models: Controls should be wired to the boiler, programmer etc. in accordance with the control scheme being used. All electrical wiring must conform to the latest IEE Wiring Regulations. E-MAIL: [email protected] Unvented Water Heaters Technical Specification 17 PremierPlus SystemFit Pipework layout will vary by model ø550 A 284 309 C 284 Unvented Water Heaters Technical Specification / Ordering Guide B 402 256 D 412 18 Dimensions Model PP120B PP150B PP170B PP210B PP250B PP300B A B C D Weights (kg) (mm) (mm) (mm) (mm) EmptyFull SF SF SF28 SF28 SF28 SF28 936 382 728 1119 563 907 1245 691 1039 1503 962 1300 1755 1139 1460 2069 1460 1805 411 446 501 501 501 501 34183 42211 45240 51262 58309 68368 Ordering Guide Model PP120B PP150B PP170B PP210B PP250B PP300B Product Code SF SF SF28 SF28 SF28 SF28 94 94 94 94 94 94 050 050 050 050 050 050 340 341 342 343 344 345 Litres Nom. 120 150 170 210 250 300 Element Rating Coil Rating kW @ 240V kW 1 1 1 1 1 1 x x x x x x 3 3 3 3 3 3 SPECIFICATION ADVICE: 01603 420128 12.5 16.4 16.0 18.3 20.0 20.0 PremierPlus SystemFit Specification of cylinder See PremierPlus, page 17. Specification of components anfoss TP9000 Programmable room D thermostat with timed Domestic Hot Water (DHW) Control Built in hot water time control. Remote room temperature sensor. Chrono-proportional control on/off. Frost protection setting. Easy to use overrides. Up to 6 time/temperature changes per day. 7 day, 5/2 or 24 hour operation. Wallplate construction. Room temperature control range 5°C to 30ºC. Holiday mode. Programmer dimensions – Width 135mm, Height 88mm, Depth 32mm. Sensor dimensions – Width 61mm, Height 45mm, Depth 22mm. Designed to meet BS EN60730-2-7 and EN60730-2-9. Maximum ambient temperature 45ºC. Timing accuracy ±1 minute. Switch rating 230Vac, 50/60Hz, 3(1)A. Switching action 2x SPDT, type 1BS. Power supply 230Vas, 50Hz Memory back up retained for life of product. Honeywell two-port valve For the central heating and domestic hot water. Model no V4043H. Voltage rating 230V ac 50Hz. Power consumption 6W. Primary water temp range 5°C to 88ºC. Max ambient temperature 50ºC. Automatic by-pass valve Model no RWC Diff 391 901. Working pressure 10 bar. Setting range 0.1 to 0.5 bar differential pressure. Max primary water temperature 120°C. Pump Model no. Grundfos UPS15-60. Working pressure 10 bar max. Voltage rating 230V ac 50Hz. Starting capacitor 2µF. Power consumption Speed setting I 40W. Speed setting II 65W. Speed setting III 95W. Enclosure protection IP42. Installation Unvented units over 15 litre capacity must be installed by a competent installer in accordance with Local Regulations: England & Wales – Building Regulations G3. Scotland – Technical Standards P3. N. Ireland – Building Regulations P5. Fixing For floor mounting. Plumbing Connections Inlet: 22mm compression. Outlet: 22mm compression / ¾" BSP male. Primary connections: 22mm O/D Copper on 120/150L models / 28mm OD Copper on other models. ½" T&P relief valve 15mm compression outlet supplied fitted. Cold Water Control 22mm HiFlo cold water valve assembly comprising 3.5 bar pressure reducer, line strainer, non-return valve. Expansion core unit comprising 6 bar expansion valve and check valve factory fitted. Cold water control valve (3.5 bar) is supplied for use with mains pressure of 20 bar to 1.5 bar, at the lower pressure, performance will be reduced accordingly. Normal working pressure is 3.5 bar. Water Expansion Remote expansion vessel 12 litre (120 + 150), 18 litre (170 + 210) and 24 litre (250 + 300). NOTE: A separate expansion vessel (12 litre) is supplied for sealed primary systems. Flow Rates Up to 55 litres per min @ 6 bar pressure. Minimum Water Supply Requirements 20 litres per minute flow and 1.5 bar pressure. (At lesser values, the unit will operate but outlet flow rates may be unacceptable, especially with multiple draw-offs). Please contact our Specification Advice Team to discuss specific site conditions if the above minimum requirement cannot be met. Secondary Circulation Via 15mm tee piece on inlet pipe (supplied capped). A WRAS listed bronze circulating pump (not supplied) will be required. Compatible Boilers Electric, gas or oil fired – sealed system or open vent type, fitted with integral control thermostat and thermal cut-out. Tundish 15mm compression inlet and 22mm compression outlet factory fitted. Electrical Connection is direct to terminals in the immersion heater which must be permanently connected to the supply through a double-pole linked isolating switch with a minimum breaking capacity of 13A. Indirect controls should be wired to the boiler, in accordance with the control scheme being used. All electrical installation must conform to the latest IEE Wiring Regulations. Santon’s Specification Advice Team is available to discuss requirements for specific projects, applications and product selection. E-MAIL: [email protected] Unvented Water Heaters Technical Specification 19 PremierPlus Solar Technical Specification Direct Solar Water Heating ø550 A Indirect ø550 29 A ø550 29 29 29 C B C 20 412 370 370 412 D A BC C B C D 81 412 370 412 81 30º 45º 30º 45º Dimensions Direct A B C D Weights (kg) (mm) (mm) (mm) (mm) EmptyFull PP170ESOLAR PP210ESOLAR PP260ESOLAR PP300ESOLAR 1245 1502 1795 2067 - - - - 925 1184 1411 1715 - - - - 35.5205.5 42.5255.5 58.0318 61.5361.5 1401 1502 1760 2067 923 1095 1258 1573 1019 1184 1391 1715 732 1009 1160 1438 45.5235.5 47.5257.5 56.5306.5 66.5366.5 Indirect PP190BSOLAR PP210BSOLAR PP250BSOLAR PP300BSOLAR SPECIFICATION ADVICE: 01603 420128 PremierPlus Solar Technical Specification / Ordering Guide Auxiliary Auxiliary Solar Recovery Heating Coil Coil Coil Time Time Rating SurfaceSurface AreaArea (kW) (m²) (m²) (mins)(mins) Direct PP170ESOLAR - - PP210ESOLAR - PP260ESOLAR - PP300ESOLAR -1.1-126 -1.1-147 -1.1-178 -1.1-210 Indirect PP190BSOLAR 15.0 PP210BSOLAR15.0 PP250BSOLAR18.8 PP300BSOLAR18.8 0.61 0.68 0.79 0.79 1.1 1.1 1.1 1.1 22 17 19 22 - Solar Water Heating Coil Areas 21 Cylinder Capacities and Performance Direct Total Auxiliary solartop-up heated hot water capacitycapacity (litres) (litres) PP170ESOLAR170 PP210ESOLAR210 PP260ESOLAR260 PP300ESOLAR300 Standard Heatloss (kWh/24h)(kWh/365d) 120 140 170 200 1.40 1.70 1.98 2.28 511 621 723 832 120 120 145 175 1.52 1.70 1.96 2.28 555 621 715 832 Indirect PP190BSOLAR190 PP210BSOLAR210 PP250BSOLAR250 PP300BSOLAR300 Ordering Guide Product Capacity Nominal CodeAuxiliary Element @ 240V Direct (litres)(kW) PP170ESOLAR PP210ESOLAR PP260ESOLAR PP300ESOLAR 94 94 94 94 050 050 050 050 309 336 310 338 170 210 260 300 1 2 2 2 x x x x 3 3 3 3 94 94 94 94 050 050 050 050 440 441 442 443 190 210 250 300 1 1 1 1 x x x x 3 3 3 3 Indirect PP190BSOLAR PP210BSOLAR PP250BSOLAR PP300BSOLAR E-MAIL: [email protected] PremierPlus Solar Solar Water Heating Technical Specification 22 Specification Guarantee Nominal Capacities 190, 210, 250 & 300 litres (indirect). 170, 210, 260 & 300 litres (direct). Element Long-life Superloy 825 sheathed element, incorporated into an easily removable heater plate, should replacement be necessary. Rated 3.0kW @ 240V. Outer Casing White plastic-coated, corrosion-proofed steel with grey high impact thermoplastic moulded top and bottom covers. Thermal Insulation CFC/HCFC free (ODP zero) fire retardant expanded polyurethane. 50mm thickness. GWP 3.1 (Global Warming Potential). Inner Container Duplex stainless steel, pressure tested to 15 bar. Primary Coil (for auxiliary heating boiler) 22mm diameter stainless steel. Coil-in-coil design for improved performance. Solar Coil 25mm diameter stainless steel. Coil-in-coil design and large surface area for improved performance. Thermostat Element thermostat adjustable from 10°C to 70°C. Factory fitted cylinder thermostat adjustable to 70°C for auxiliary heating source. A pocket is provided for solar controls suitable for insertion of solar controller temperature probe. Safety Features All Models: Temperature and pressure relief valve, factory set to operate at 10 bar and 90°C. High limit thermostat, factory set at 80°C Direct Models: Manually-resettable cut-out, set to 80°C. A 2-port motorised valve is supplied with twin coil models to provide overtemperature protection when heating using the auxiliary heating (boiler) coil. A factory-fitted thermal cut-out is provided for integration in to a solar circuit. Anode None required. Approvals Kiwa and Nemko approved. CE marked. Manufactured in the UK in a BS EN ISO 9001:2008, ISO 14001:2004 and BS OHSAS 18001:2007 registered factory. The PremierPlus Solar Duplex stainless steel vessel carries a full 30 year on-site parts and labour transferable guarantee against faulty manufacture or materials provided that: • It has been correctly installed as per the instructions contained in the instruction manual and all relevant Codes of Practice and Regulations in force at the time of installation. • It has not been modified in any way, other than by Santon. • It has not been frost damaged. • It has only been used for the storage of potable water. • It has not been tampered with or been subjected to misuse or neglect. • Within 60 days of installation the user completes and returns the certificate supplied along with the proof of purchase to register the product. • It has been installed in the United Kingdom. Expansion vessel and hot water controls are guaranteed for a period of 5 years from the date of purchase. The PremierPlus Solar components, immersion heater and thermal controls are guaranteed for a period of 2 years from the date of purchase. Evidence of purchase and date of supply must be submitted. The unit is not guaranteed against damage due to frost. The guarantee is transferable. This guarantee does not affect your statutory rights. SPECIFICATION ADVICE: 01603 420128 PremierPlus Solar Technical Specification Unvented units over 15 litre capacity must be installed by a competent installer in accordance with Local Regulations: England & Wales – Building Regulation G3. Scotland – Technical Standards P3. N. Ireland – Building Regulation P5. Fixing Feet on bottom moulding for floor mounting. Plumbing Connections Inlet/Outlet. 22mm compression fittings / ¾" BSP parallel thread. Indirect Coil 22mm compression fittings / ¾" BSP parallel thread. Solar Coil 22mm compression fittings / ¾" BSP parallel thread. Temperature and Pressure Relief Valve 15mm compression outlet. Cold Water Control Integrated cold water control set comprising pressure reducing valve and strainer – factory set at 3.5 bar, expansion relief valve – factory set at 6 bar and check valve. 22mm compression fittings. Mains pressure Min 1.0 bar, Max 16 bar. Flow Rates Up to 55 litres per minute @ 6 bar pressure. Operating Pressure 3.5 bar. Expansion Relief Valve Pressure 6.0 bar. Operating Temperature Recommended 60°C. Adjustable 10 – 70°C on auxiliary heating controls. Water Expansion 24 litre remote expansion vessel supplied with all models. Minimum Water Supply Requirements Recommended minimum supply pressure – 1.5 bar/20 l/min flow rate. If there are any doubts about water supply pressure or flow rates, please contact our Specification Advice Team to discuss. Secondary Circulation ½" BSP female connection provided. Secondary circulation is NOT recommended for units using off-peak electricity tariffs for auxiliary heating. Pressure Testing Units are tested to 15 bar. Compatible Boilers Electric, gas or oil fired – open vent or sealed system type, fitted with integral control thermostat and cut-out. Tundish 15mm compression inlet and 22mm compression outlet. Electrical The solar thermal cut-out (factory-fitted) should be wired in series with the solar controls (not supplied). Direct Models: Connection is to the combined thermostat/thermal cut-out, housed within the integrated controls housing. The electrical supply must be permanently connected via a double pole linked isolating switch with a minimum break capacity of 13A. Indirect twin coil models: Controls should be wired to the boiler, programmer etc. in accordance with the control scheme being used. The solar coil must be connected to a fully pumped solar primary system that should be controlled by a suitable solar controller and hydraulic set. The solar controller temperature sensor must be inserted in the pocket supplied on the heater. All electrical wiring must conform to the latest IEE Wiring Regulations. E-MAIL: [email protected] Solar Water Heating Installation 23 Aquaheat Unvented Water Heaters Commercial Unvented Water Heaters – 15 litres and under Santon is one of the leading brands in the UK for unvented water heating. For commercial applications, unvented water heating has a number of advantages over more traditional methods. For example, one unvented unit can supply a number of outlets without the need for special taps. As a result, the unvented option can often prove to be more cost effective to install than a traditional vented system. Unvented water heaters are connected to the mains water supply with the advantage that full mains pressure can be obtained from both the hot and cold taps. Aquaheat is a range of small unvented water heaters available in capacities of 7, 10 and 15 litres. Featuring copper inner containers, Aquaheat provides a cost effective solution for a variety of commercial applications including dishwashing, handwashing and low demand canteen and workshop use. 24 Ease of installation has long been a trademark of Santon products and this range is no exception with the units ideally suited to both floor and wall mounting. Aquaheat units are supplied with an Expansion Relief Valve, ensuring the Santon reputation for supplying safe, quality products is maintained. Commercial Unvented Selection Guide Capacity of Water Heater 7 litres 10 litres 15 litres Number of Basins 1–2 2–3 3–4 Note: These figures are for guidance only and local conditions should be taken into account when sizing the installation. For full details contact our Specification Advice Hotline on 01603 420128 or fax 01603 420229. SPECIFICATION ADVICE: 01603 420128 Aqualine Aqualine is the ultimate in electric unvented water heating. All operational and safety controls are contained within the case. This includes a TMV2 thermostatic blending valve which allows the unit to store water at a high temperature and dispense at handwash temperature. Water stored above 60ºC not only gives more useable blended water output, it also considerably reduces the possibility of harbouring bacteria, making aqualine the ideal product where ‘safe’ hot water is required – for example schools, nursing homes and nurseries. The range features 7, 10 and 15 litre models, with the latter available in 3kW and 4.5kW loadings. This enables the specifier and installer to cover applications from light duty commercial handwashing to multioutlet installations. Each unit contains a factory-fitted pressure and temperature relief valve, TMV2 thermostatic blending valve, a control thermostat and a resettable over-temperature cut-out for additional safety. Commercial Unvented Selection Guide Capacity of Water Heater 7 litres 10 litres 15 litres Number of Basins 1–2 2–3 3–4 Note: These figures are for guidance only and local conditions should be taken into account when sizing the installation. For full details contact our Specification Advice Hotline on 01603 420128 or fax 01603 420229. E-MAIL: [email protected] Unvented Water Heaters Commercial Unvented Water Heaters – with TMV2 Thermostatic Blending Valve 25 Small Unvented Unvented Water Heaters Installing Commercial Unvented Water Heaters and Kit Selector 26 The following information is intended as a guide – if in any doubt, please contact our Specification Advice Hotline on 01603 420128 or fax 01603 420229. Small Unvented Installation (Up to 15 litres in capacity) When water is heated, it expands and increases in volume by up to 4%. This increase needs to be accommodated within the system. With unvented water heaters below 15 litres in capacity, such expansion may be accommodated within the cold water supply pipe provided all of the following conditions are met: A.The maximum supply pressure is below 4.1 bar. B.The minimum length of the supply pipework from the heater to the nearest cold draw-off is not less than that specified for the heater used. C.The expansion in the cold water main is not prevented or restricted by a stop valve, non-return valve, water meter or similar device. A typical installation of a Santon Aquaheat without expansion kit A typical installation of a Santon Aqualine without expansion kit For installations where any of the above conditions cannot be met, an expansion vessel and other relevant accessories must be used to accommodate expansion. In all installations where the supply pressure exceeds 4.1 bar, a pressure reducing valve must be fitted along with other necessary valves. SPECIFICATION ADVICE: 01603 420128 Aquaheat Installing Commercial Unvented Water Heaters and Kit Selector For inlet water pressure up to 4.1 bar where expansion back down the mains is not possible (using kit ALK05) Unvented Water Heaters For inlet water pressure up to 4.1 bar (with no additional kits used) 27 For inlet water pressure above 4.1 bar (using kit ALK04) E-MAIL: [email protected] Aqualine Installing Commercial Unvented Water Heaters and Kit Selector Unvented Water Heaters For inlet water pressure up to 4.1 bar (with no additional kits used) For inlet water pressure up to 4.1 bar where expansion back down the mains is not possible (using kit ALK02) 28 For inlet water pressure above 4.1 bar (using kit ALK01) SPECIFICATION ADVICE: 01603 420128 Small Unvented Installing Commercial Unvented Water Heaters and Kit Selector Is the supply pressure guaranteed to be (and remain) below 4.1 bar YES NO Can expanded water be accommodated in the pipework without hot water entering any supply pipe to which a cold water draw-off is connected? (If there are any valves preventing reverse flow, select “No”). YES NO Aquaheat: Use ALK04 Aquaheat: Use ALK05 Aqualine: Use ALK01 Aqualine: Use ALK02 No kit is required ALK03/ALK07 – Typical Installation Outlet taps Hot outlet Blended water to outlets ALK03/07 Blending Valve Cold water in Water Heater Balanced cold water supply E-MAIL: [email protected] Unvented Water Heaters Kit Selection Chart 29 Aquaheat Accessories Unvented Water Heaters ALK03 TMV2 Thermostatic blending valve. Suitable for general purpose applications, the blending valve allows water to be stored at high temperature and then blended with cold water to deliver a preset outlet temperature. Non-return valves prevent cross-contamination. Operating pressure 0.2 bar to 6.0 bar. Other benefits include extended system capacity, precise control of outlet temperature (range 35°C – 60°C) and a lockable control knob. ALK07 – TMV3 Thermostatic blending valve. The TMV3 approved blending valve allows water to be stored at high temperature and then blended with cold water to deliver a preset outlet temperature. Non-return valves prevent crosscontamination. Operating pressure 0.2 bar to 5.0 bar. Other benefits include extended system capacity, precise control of outlet temperature (range 38°C – 46°C) and a unique adjuster key to prevent unauthorised temperature adjustment. Connections •15mm compression. 30 ALK04 – Expansion vessel, pressure reducer/ strainer and non-return valve. For all situations where the mains pressure is greater than 4.1 bar. The pressure reducing valve reduces incoming pressure to 3.5 bar while the strainer filters coarse impurities from the incoming water. The non-return valve prevents back-flow of hot water which could cause cross-contamination of the inlet water. The pressure reducing valve must be installed on the mains side of the expansion vessel. For balanced hot/cold water supplies, the pack should be fitted on the mains side of the cold water draw off; this is particularly important where mixers are used. Connections •Pressure reducing valve ½" BSP female. •Expansion vessel ½" BSP male. •Non-return valve 15mm x 15mm compression. ALK05 – Expansion vessel and non-return valve. For Aquaheat heaters where expanded water cannot be accommodated in the pipework and where the mains pressure is guaranteed never to exceed 4.1 bar. The expansion vessel, when fully charged, will absorb all expanded water produced by the Aquaheat heater. Supplied pre-charged to 4.1 bar. The non-return valve prevents back-flow of hot water which could cause crosscontamination of the inlet water. Connections • Expansion vessel ½" BSP male. • Non-return valve 15mm x 15mm compression. ALK06 – Pressure and temperature relief valve. For on-site fitting to Aquaheat heaters. Recommended by Santon to give an added level of safety. Preset to open at 7 bar and 90ºC. ALK06 is connected to the outlet of the heater. Connections • Drain ½" BSP female. • Inlet and Outlet 15mm compression. SPECIFICATION ADVICE: 01603 420128 Aqualine A full range of accessories is available for installation with Aqualine unvented water heaters. These are supplied as ‘accessory kits’ to suit different applications. When installing small unvented water heaters, it is essential that the correct accessory kits are used. A knowledge of the maximum incoming water pressure is an essential requirement; where this is not known, the local water authority should be consulted. ALK01 – Expansion vessel, expansion relief valve, pressure reducer/strainer and non-return valve. For all situations where the mains pressure is greater than 4.1 bar. The pressure reducing valve reduces incoming pressure to 3.5 bar while the strainer filters coarse impurities from the incoming water. The expansion valve acts as a back-up to the expansion vessel, opening at 6 bar. The non-return valve prevents back-flow of hot water which could cause cross-contamination of the inlet water. The pressure reducing valve must be installed on the mains side of the expansion vessel. For balanced hot/cold water supplies, the pack should be fitted on the mains side of the cold water draw off; this is particularly important where mixers are used. Connections •Pressure reducing valve ½" BSP female. •Expansion vessel ½" BSP male. •Expansion relief valve inlet ½" BSP male, discharge ½" BSP female. •Non-return valve 15mm x 15mm compression. ALK02 – Expansion vessel, expansion relief valve, and non-return valve. For heaters where expanded water cannot be accommodated in the pipework and where the mains pressure is guaranteed never to exceed 4.1 bar. The expansion vessel, when fully charged, will absorb all expanded water produced by the heater. Supplied precharged to 4.1 bar. The expansion valve acts as a back-up to the expansion vessel, opening at 6 bar. The non-return valve prevents back-flow of hot water which could cause cross-contamination of the inlet water. Connections •Expansion vessel ½" BSP male. •Expansion relief valve inlet ½" BSP male, discharge ½" BSP female. •Non-return valve 15mm x 15mm compression. Ordering Guide – Aquaheat Model Ref. ALK03 ALK07 ALK04 Product Code 94 970 010 94 970 037 94 970 011 Model Ref. ALK05 ALK06 Product Code 94 970 012 94 970 013 Ordering Guide – Aqualine Model Ref. Product Code ALK01 ALK02 94 970 008 94 970 009 E-MAIL: [email protected] Unvented Water Heaters Accessories 31 Aquaheat Unvented Water Heaters Technical Specification 32 Dimensions Model AH7/2.2 AH10/2.2 AH15/2.2 A B C Weights(kg) (mm)(mm)(mm) Empty Full 356240240 4.9 11.9 442240240 5.9 15.9 417330330 10.0 25.0 Ordering Guide Model Ref. Product Code Ltrs Rating AH7/2.2 94 050 001 7 AH10/2.2 94 050 002 10 AH15/2.2 94 050 003 15 2.2kW @ 240V (2.0kW @ 230V) single phase AC 2.2kW @ 240V (2.0kW @ 230V) single phase AC 2.2kW @ 240V (2.0kW @ 230V) single phase AC SPECIFICATION ADVICE: 01603 420128 Aquaheat Specification Installation Element Alloy sheathed element, incorporated into an easily removable heater plate, should replacement be necessary. Inner Container Heavy gauge copper suitable for a maximum working pressure of 6 bar (pressure tested to 15 bar). A minimum supply pressure of 1 bar is recommended. Outer Casing The main body is substantial gauge sheet steel, anti-corrosion treated, and finished in white stoved enamel. End covers are moulded in grey ABS. The back has three fixing points for wall mounting. Insulation Approved CFC/HCFC free (ODP zero) polyurethane foam. GWP 2.72 (Global Warming Potential) Safety Feature IPX4 rated. Expansion Relief Valve This is supplied with the heater and MUST be fitted with every installation. It is set at 6 bar. A temperature and pressure relief valve can be used (order ref. ALK06). Expansion/Pressure Kits If the inlet water pressure is above 4.1 bar, it is essential that kit ALK04 is also installed with the heater. This kit comprises expansion vessel, non-return valve and pressure reducer/strainer. If the inlet pressure is guaranteed to be below 4.1 bar where full expansion back down the mains is not possible, kit ALK05 must be installed (comprises expansion vessel and non-return valve). Thermostat Rod type, adjustable 10°C – 70°C with integral, manually re-settable, over temperature cut-out. Plumbing Connections Inlet and outlet are 15mm copper tails. An expansion relief valve is supplied with the unit and must be fitted to every installation. The relief valve discharge pipe must be connected to waste (drain) via a tundish. The drain pipe from the tundish must fall continuously and be 22mm diameter copper pipe. It must discharge in a visible and safe place. The pipe must not be reduced in bore or blocked under any circumstances and should be protected from frost. Under no circumstances must hot water or expanded water be allowed to contaminate the supply to a cold water draw off. Electrical This unit is supplied with 1 metre of 3 core cable fitted. The installation must comply with BS 7671 ‘Requirements for electrical installations’ (IEE Wiring Regulations). It must be fully earthed and permanently connected to the electrical supply through a double pole linked isolating switch with minimum breaking capacity suitable for the loading. Approvals BEAB approved. CE marked. Manufactured in the UK in a BS EN ISO 9001:2008, ISO 14001:2004 and BS OHSAS 18001:2007 registered factory. Guarantee Two years product guarantee, from date of purchase, with on-site service support. Full details are contained in the Installation Instructions supplied with each unit. E-MAIL: [email protected] Unvented Water Heaters Technical Specification 33 Aqualine Unvented Water Heaters Technical Specification 34 Dimensions Model AL07/3 AL10/3 AL15/3 AL15/4.5 A (mm) B (mm) 456 542 517 517 240 240 330 330 C Weights (kg) (mm) EmptyFull 240 240 330 330 6.513.5 7.517.5 11.626.6 11.626.6 Ordering Guide Model Ref. Product Code Ltrs Rating AL07/3 94 050 012 7 AL10/3 94 050 013 10 AL15/3 94 050 014 15 AL15/4.5 94 050 015 15 3.0kW @ 240V (2.8kW @ 230V) single phase AC 3.0kW @ 240V (2.8kW @ 230V) single phase AC 3.0kW @ 240V (2.8kW @ 230V) single phase AC 4.5kW @ 240V (4.1kW @ 230V) single phase AC SPECIFICATION ADVICE: 01603 420128 Aqualine Specification Installation Element Alloy sheathed element, incorporated into an easily removable heater plate, should replacement be necessary. Inner Container Heavy gauge copper suitable for a maximum working pressure of 6 bar (pressure tested to 15 bar). A minimum supply pressure of 1 bar recommended. Outer Casing The main body is substantial gauge sheet steel, anti-corrosion treated, and finished in white stoved enamel. End covers are moulded in grey ABS. The back has three fixing points for wall mounting. Insulation Approved CFC/HCFC free (ODP zero) polyurethane foam. GWP 2.72 (Global Warming Potential). Safety Feature IPX4 rated. TMV2 Thermostatic Blending Valve Precise control of outlet temperature (range 35°C – 60°C) and lockable control knob. Temperature stability ±2°C. Expansion/Pressure Kits If the inlet water pressure is in excess of 4.1 bar, it is essential that the Santon unvented kit ALK01 is also installed with the heater. This kit comprises expansion vessel, expansion relief valve, non-return valve and pressure reducer/strainer. In instances where the water pressure is below 4.1 bar, but expansion cannot occur back down the mains, kit ALK02 must be used (comprises expansion vessel, expansion relief valve and non-return valve). Pressure and Temperature Relief Valve This is factory-fitted to the unit, accessible beneath the removable access cover and is set at 7 bar/90°C. Thermostat Rod type, adjustable 10°C – 70°C with integral manually re-settable, over temperature cut-out. Plumbing Connections Inlet and outlet are 15mm copper tails. The factory-fitted temperature and pressure relief valve discharge pipe must be connected to waste (drain) via the tundish supplied. The drain pipe from the tundish must fall continuously and be 22mm diameter copper pipe. It must discharge in a visible and safe place. The pipe must not be reduced in bore or blocked under any circumstances and should be protected from frost. Electrical This unit is supplied with 1 metre of 3 core cable fitted. The installation must comply with BS 7671 ‘Requirements for electrical installations’ (IEE Wiring Regulations). It must be fully earthed and permanently connected to the electrical supply through a double pole linked isolating switch with minimum breaking capacity suitable for the loading. Approvals Nemko approved. CE marked. Manufactured in the UK in a BS EN ISO 9001:2008, ISO 14001:2004 and BS OHSAS 18001:2007 registered factory. Guarantee Two years product guarantee, from date of purchase, with on-site service support. Full details are contained in the Installation Instructions supplied with each unit. E-MAIL: [email protected] Unvented Water Heaters Technical Specification 35 Aquaheat SS Unvented Water Heaters Commercial Unvented Water Heaters – Horizontal and Vertical The range of Aquaheat SS unvented horizontal and vertical water heaters are available in 50 to 100 litre capacities. Whilst the attractive, modern design makes the Santon water heaters perfect for wall mounting, they are also able to be mounted within air conditioning ceiling voids. With no sacrificial anode necessary there is no need for regular maintenance checks or costly replacements. The superior heat loss characteristics and resultant energy efficiency perfectly demonstrates Santon’s commitment to providing performance and value for money. Using only high grade Duplex stainless steel the cylinders are manufactured in our own factory in the United Kingdom. Fully tested to meet stringent UK and European safety standards, these low maintenance, high performance heaters are supplied with a 10 year cylinder warranty with on-site service support. 36 Aquaheat SS units are supplied with an expansion vessel, temperature gauge and cold water control kit ensuring the Santon reputation for supplying safe, quality products is maintained. SPECIFICATION ADVICE: 01603 420128 Aquaheat SS Unvented Water Heaters Commercial Unvented Water Heaters – Horizontal and Vertical 37 Commercial Unvented Selection Guide Capacity of Water Heater 50 litres 80 litres 100 litres Number of Basins 4–5 5–8 8 – 10 Note: These figures are for guidance only and local conditions should be taken into account when sizing the installation. For full details contact our Specification Advice Hotline on 01603 420128 or fax 01603 420229. E-MAIL: [email protected] Aquaheat SS Technical specification Unvented Water Heaters Vertical A A D E B C D E B C Horizontal 38 B B D E C A D E C A Dimensions Model A B C D E Weights (kg) (mm) (mm)(mm) (mm)(mm) EmptyFull H50 H80 H100 V50 V80 V100 700 451472 237100 958 451472 237100 1146451472 237100 700 451472 103100 958 451472 103100 1146451472 103100 18 68 24104 30130 18 68 24104 30130 Ordering Guide Model Ref. Product Code Ltrs H50 H80 H100 V50 V80 V100 94 94 94 94 94 94 050 050 050 050 050 050 047 049 051 053 055 057 50 80 100 50 80 100 Rating 3kW 3kW 3kW 3kW 3kW 3kW @ @ @ @ @ @ 240V 240V 240V 240V 240V 240V (2.8kW (2.8kW (2.8kW (2.8kW (2.8kW (2.8kW SPECIFICATION ADVICE: 01603 420128 @ @ @ @ @ @ 230V) 230V) 230V) 230V) 230V) 230V) Aquaheat SS Technical specification Element Long life Incoloy 825 element and plate. Inner Container Duplex stainless steel suitable for a maximum working pressure of 10 bar (pressure tested to 16 bar). A minimum supply pressure of 1 bar recommended. Outer casing White painted steel, stove enamelled corrosion resistant. Thermal Insulation CFC/HCFC-free (ODP zero) flame retardant expanded polyurethane. 38mm thickness. GWP 3.1 (Global warming potential). Thermostat Electromechanical capillary type adjustable from 10ºC to 70ºC. Safety Features All models: Factory-fitted temperature and pressure relief valve set at 90ºC and 10 bar. Pressure reducing valve at 3.5 bar. Non return valve. Pressure relief valve at 6 bar. Expansion vessel. Over-temperature capillary cut-out set at 85ºC. All units pressure tested to 15 bar. IPX4 rated. Anode None required. Installation Unvented units over 15 litre capacity must be installed by a competent installer in accordance with Local Regulations: England and Wales – Building Regulations G3. Scotland – Technical Standards P3. N. Ireland – Building Regulations P5. Fixings Horizontally or vertically wall-mounted with brackets provided. Plumbing Connections 22mm compression fittings / ¾" BSP male connections. Inlet and outlet are 22mm copper tails. An expansion relief valve is supplied with the unit and must be fitted to every installation. The relief valve discharge pipe must be connected to waste (drain) via a tundish. The drain pipe from the tundish must fall continuously and be 22mm diameter copper pipe. It must discharge in a visible and safe place. The pipe must not be reduced in bore or blocked under any circumstances and should be protected from frost. Under no circumstances must hot water or expanded water be allowed to contaminate the supply to a cold water draw off. Temperature and Pressure Relief Valve 22mm compression outlet. Cold Water Control Integrated cold water control set comprising pressure reducing valve and strainer – factory-set 3.5 bar, expansion relief valve – factory-set at 6 bar and check valve. 22mm compression fittings. Tundish (supplied as part of kit). Mains pressure; minimum 1 bar, maximum 16 bar. Rating 240V AC, 50/60Hz Electrical The installation must comply with BS 7671 ‘Requirements for electrical installations’ (IEE Wiring regulations). It must be fully earthed and permanently connected to the electrical supply through a double pole linked isolating switch with minimum breaking capacity suitable for the loading. Optional Accessories TMV2 (ALK03) and TMV3 (ALK07) thermostatic blending valves may also be used in conjunction with the Aquaheat SS (see page 30). Approvals Nemko and Kiwa approved. CE marked. Manufactured in the UK in a BS EN ISO 9001:2008, ISO 14001:2004 and BS OHSAS 18001:2007 registered factory. Guarantee The Aquaheat SS duplex stainless steel cylinder carries a full 10 year on-site parts and labour. All other components carry a 2 year guarantee. Full details are contained in the Installation Instructions supplied with each unit. E-MAIL: [email protected] Unvented Water Heaters Specification 39 Aquarius Vented Water Heaters Sink and Basin Supply 10 Litres and Under 40 As small vented water heaters are typically installed directly over or under the sink, this range of products is commonly referred to as “Point of Use”. The majority of units are installed directly over or adjacent to the point of application for light commercial duty such as washing cups and dishes. They can be supplied either directly from the mains or from an elevated cistern or feed tank (a minimum head pressure of 4 metres is required). Aquarius Vented Oversink An oversink unit is supplied with an inlet valve that, when opened, allows the mains cold water supply to enter the heater and displace the hot water stored in the cylinder. As the valve controls the displacement, the outlet is open to atmosphere so that when the unit heats up, the expanded water is allowed to drip from the spout into the basin. No other outlet should be used in conjunction with this type of product. Aquarius oversink products are available in 7 and 10 litre capacities with options for 3.0kW and 1.2kW element ratings. Typically, they are supplied from the water mains although supply from a cistern can be used as long as there is a minimum head pressure of 4 metres. The 3.0kW element provides a fast recovery from cold whereas the 1.2kW version means that Aquarius can be fitted in situations where the power supply may be limited, such as portable or temporary buildings. SPECIFICATION ADVICE: 01603 420128 Aquarius Sink and Basin Supply 10 Litres and Under Aquarius Vented Undersink Undersink models can also be connected to a cold water cistern or feed tank as long as the vented tap is used or a vent pipe is plumbed from the hot pipework to discharge the expansion back into the cistern. In such cases, the base of the cistern must be no higher than 10 metres above the top of the water heater and a vent pipe must be used. Vented Water Heaters These can also be fed from the mains but only if one of the self venting taps (see pages 44-45) is used. As with the oversink model, the special tap acts as an inlet valve so that when the tap is turned on, the cold supply is allowed to flow through the water heater, displacing the hot water into the basin. The outlet part of the tap is always open to atmosphere allowing the expanded water to drip from the tap into the basin during the heat up cycle. Undersink vented water heaters are only able to supply one basin when used with vented taps. Aquarius undersink products are available in 7 and 10 litre capacities with options for 3.0kW and 1.2kW element ratings. 41 The 3.0kW element provides a fast recovery from cold whereas the 1.2kW version means that Aquarius can be fitted in situations where the power supply may be limited, such as portable or temporary buildings. E-MAIL: [email protected] Aquarius Technical Specification Undersink Vented Water Heaters Oversink 42 Dimensions Oversink A7/3 A7/1 A10/3 A (mm) B (mm) C Weights (kg) (mm) EmptyFull 356 356 442 240 240 240 240 240 240 4.911.9 4.911.9 5.915.9 356 356 442 240 240 240 240 240 240 4.911.9 4.911.9 5.915.9 Undersink AU7/3 AU7/1 AU10/3 Ordering Guide Oversink Product Code Ltrs A7/3 94 010 001 7 A7/1 94 010 002 7 A10/3 94 010 003 10 Rating 3.0kW @ 240V (2.8kW @ 230V) single phase AC 1.2kW @ 240V (1.2kW @ 230V) single phase AC 3.0kW @ 240V (2.8kW @ 230V) single phase AC Undersink AU7/3 94 010 008 7 AU7/1 94 010 009 7 AU10/3 94 010 010 10 3.0kW @ 240V (2.8kW @ 230V) single phase AC 1.2kW @ 240V (1.2kW @ 230V) single phase AC 3.0kW @ 240V (2.8kW @ 230V) single phase AC SPECIFICATION ADVICE: 01603 420128 Aquarius Technical Specification Element Copper sheathed Element, incorporated into an easily removable heater plate, should replacement be necessary. Inner Container Pressure tested to 1.38 bar (20psi). A minimum head pressure of three metres is required. Outer Casing The main body is substantial gauge sheet steel, anti-corrosion treated and finished in white stoved enamel. End covers are moulded in grey ABS. The back has three fixing points for wall mounting. Insulation Approved CFC/HCFC free (ODP zero) polyurethane foam. GWP 2.72 (Global Warming Potential). Safety Feature IPX4 rated. Thermostat Capillary type, adjustable 10°C – 70°C. Safety Cut-out Models are available with a thermal fuse cut-out fitted in series with the adjustable thermostat. Swivel Outlet – Oversink Stainless steel tube 300mm, with 15mm push-fit connection. No other pipework or spout or tap should be connected to the outlet. Inlet – Oversink An inlet valve is supplied with 15mm compression connections. Connections – Undersink 15mm Copper tails. Electrical The installation must comply with BS 7671 ‘Requirements for electrical installations’ (IEE Wiring Regulations). It must be fully earthed and permanently connected to the electrical supply through a double pole linked isolating switch with minimum breaking capacity suitable for the loading. Approvals BEAB and Kiwa approved. CE marked. Manufactured in the UK in a BS EN ISO 9001:2008, ISO 14001:2004 and BS OHSAS 18001:2007 registered factory. Guarantee Two years product guarantee, from date of purchase, with on-site service support. Full details are contained in the Installation Instructions supplied with each unit. E-MAIL: [email protected] Vented Water Heaters Specification 43 Aquarius Vented Water Heaters Vented Taps The Santon range of taps has been chosen to complement the Aquarius range of water heaters. It consists of vented hot taps and matching cold taps for use with vented undersink water heaters, as well as standard taps which can be used with any other Santon storage unit. The taps are robust and made in traditional cast brass with a chrome finish. A typical installation of an Aquarius Vented Undersink heater using a vented tap. 44 Vented Basin Hot Tap – TXH01 40 Compression fittings 15mm O/D pipe 168 50 82 69 87 1/2" BSP (backnut & washer supplied) This tap is constructed to control the flow of incoming mains water supply to an open outlet type electric water heater. This displaces the heated water in an unrestricted flow through the tap’s permanently open outlet. This vented hot tap is for full bore plumbing. Above the basin it is identical to the universal taps, so a matching cold tap is available if required. Vented Pillar Hot Tap – TXH02 151 168 Compression fittings 15mm O/D pipe 50 1/2" BSP (backnut & washer supplied) This is a pillar (or high neck) tap version of model TXH01. 82 130 90 SPECIFICATION ADVICE: 01603 420128 Aquarius Vented Taps 69 90 119 87 1/2" BSP (backnut & washer supplied) These taps are packed individually with both a red and blue bezel and are normally used in cold tap form to match the TXH01. Ref. TXU02: Order Code 94 970 018 This is a pillar (or high neck) tap version of model TXU01 to match TXH02. Vented Mixer Tap – TXM01 50 180 Compression fittings 15mm O/D pipe 168 50 1/2" BSP (backnut & washer supplied) 82 73 This is similar in operation to the vented hot tap but has the additional advantages of mixing the heated and cold water at the outlet and is ideally suited to kitchen use. 140 180 Ordering Guide Model Ref. TXH01 TXH02 TXU01 TXM01 Product Code 94 94 94 94 970 970 970 970 E-MAIL: [email protected] 014 015 017 016 Vented Water Heaters Universal Basin Tap – TXU01 45 EV 2008 Hand Hygiene Efficient and Economical Handwashing Electric handwash units offer many benefits when compared to traditional methods of supplying hot water in the washroom. They are more economical to run, as the water is heated instantaneously at the point of use, and therefore provide an energy efficient source of hot water for handwashing. Compact in size, they can be installed in a wide range of locations to provide hand wash facilities ensuring compliance with current Health and Safety legislation. The Santon EV 2008 range is cost effective, with stylish design and excellent performance. Designed to supply heated water to one basin by means of a swivel spray outlet, the units are ideal for commercial use when control of the water flow is required. The range includes an instantaneous no-touch unit for hygienic means of providing hot water for hand washing. 46 SPECIFICATION ADVICE: 01603 420128 EV 2008 Features and Benefits Performance • S ummer / Winter performance – good flow rates even with low inlet water temperature. • Flow / temperature stabilised – for consistent outlet temperature. Installation • 15mm female push-fit plumbing connection – for ease of installation. Hand Hygiene • E nergy efficient – located at point of use, eliminating long pipe runs, and heats water on demand. • C oncealed connections – option for water and electrical supply to be made from rear of unit for neater, tidier installation. Design 47 • 'Power-On' indicator. • S limline design – compact footprint requires only small amount of wall space. • Attractive styling – fits in with today’s work environment. • L ow velocity spray plate – gives consistent spray pattern over wide range of flow rates for efficient handwashing without splashing. • 200mm stainless steel swivel spout – for durability and quality appearance. • Retro fit to previous model for ease of installation. • N o-touch control dial for on/off, temperature/flow setting via a tamperproof adjuster (No Touch models). Safety Controls • Pre-set safety cut-out – prevents overheating. • P ressure relief device – prevents high pressure build-up should handwash unit become blocked or frozen. • T emperature stabiliser – ensures that the temperature of the water is maintained across the range of water pressures. E-MAIL: [email protected] EV 2008 Technical Specification EV 2008 Hand Hygiene B C A D 48 EV 2008 No Touch B C A D Dimensions Model A BC D (mm)(mm)(mm)(mm) EV 2008 36915198 240 EV 2008 NT369 151 87 240 Ordering Guide Model Ref. Product Code EV 2008/3 94 020 015 EV 2008 NT 94 020 017 Rating 3.1kW @ 240V (2.9kW @ 230V) single phase AC 3.1kW @ 240V (2.9kW @ 230V) single phase AC SPECIFICATION ADVICE: 01603 420128 EV 2008 Specification Installation Controls Combined On/Off and temperature control knob with large finger/thumb grip for ease of use. No touch controls – Easy to use No Touch on-off dial. Casing The unit is splashproof and is encased in a white moulded HIPS (High Impact Polystyrene) plastic cover which conceals both the plumbing and electrical connections. Inner Container Copper cylinder complete with Inlet and Outlet connections, pressure relief device and heating element. Element Copper sheathed rod-type. Pressure Relief A pressure relief device is incorporated in the base of the container to prevent high pressure build-up if the handwash unit should become blocked or frozen. High Temperature Cut-out A pre-set safety cut-out set at 52ºC prevents overheating should abnormal conditions arise – this will re-set at 42ºC. In addition there is a failsafe, second stage protection, which is not resettable and cuts out at 92ºC. Temperature Stabiliser An automatic temperature stabiliser ensures that the temperature of the water is maintained across the water pressure range. Pressure Range Min: 1 bar. Max: 7 bar. Connections 15mm female push-fit connection at base of unit for bottom or rear (concealed) connection. Outlet Stainless steel swivel spout with spray outlet (200mm). Spray Plate Low velocity spray giving consistent spray pattern, for efficient handwashing, over a range of flow rates. Fixing Base plate is secured to wall by two fixing screws, after which electrical and plumbing connections are made. Spout and front cover are then attached. Two screws secure the front cover. Electrical Special requirements of the IEE wiring regulations should be observed when installing in bathrooms. Units must be permanently connected to the electrical supply through a double pole linked isolating switch. Can be supplied from a ring final circuit via fused spur with a double pole linked isolating switch with a 13A minimum breaking capacity. Cable: 1.5 – 2.5mm². Approvals BEAB and Kiwa approved. Guarantee Two years product guarantee, from date of purchase, with on-site service support. Full details are contained in the Installation Instructions supplied with each unit. E-MAIL: [email protected] Hand Hygiene Technical Specification 49 Speediboil Drinking Water Boiling Water ‘On Tap’ Santon is one of the leading brands in the UK for water heating. For commercial applications, boiling water heaters have a number of advantages over traditional methods. For example, one of our smallest 2.5 litre units can supply over 150 cups of boiling water in one hour. The time saved in constantly boiling kettles to make drinks is vastly reduced, and the time spent waiting for a kettle to boil is removed completely. The Speediboil provides instant hot water. 50 Features and Benefits Performance Installation Speediboil provides a cost effective solution for a variety of commercial applications including canteens, offices, workshops, hairdressers and waiting rooms. Ease of installation has long been a trademark of Santon products and this range is no exception. Full fitting instructions and easily accessible plumbing fittings provide a quick and easy solution. SPECIFICATION ADVICE: 01603 420128 A Speediboil B F D E Boiling Water ‘On Tap’ 250mm approx Worktop Drinking Water B 30 A F D E 250mm approx G C Worktop Dimensions Capacity A B C D E F G Weight full (mm)(mm)(mm)(mm)(mm)(mm)(mm) (kg) 2.5 litres445290190 80 115 101 152 5.0 litres510335200103133101163 30 7.5 litres510335262103133101225 8.4 11.8 15.4 Ordering Guide Model Ref. Speediboil Speediboil Speediboil G Product C Code 94 200 001 94 200 002 94 200 003 Capacity 2.5 litres 5.0 litres 7.5 litres Specification Ratings 2.5kW @ 240V, all capacities. Outer Casing White ABS moulding. Thermal Insulation CFC/HCFC free (ODP zero) pre-moulded polystyrene and thermoplastic blend. Water Container Moulded thermoplastic. Removable steam condensation chamber for maintenance access. Heat Unit Low watts density Superloy element for long life. Thermostat Electronic to control water temperature up to boiling point. Safety Features All models are low-pressure vented. Dry start protection by self re-setting bi-metal thermal cut-out. Boil dry protection by manually resettable disc-type bi-metal cut-out. IPX2 rated. Plumbing Cold water feed should be taken directly from the mains – min pressure 0.5 bar (7psi), max pressure 10 bar (145psi). Bottom or rear entry using 15mm push-fit connections. Electrical Supply (bottom or rear entry) can be taken from a suitable ring final circuit via a fused spur but must be via a double-pole linked isolating switch with a minimum break capacity of 13A. All electrical work must comply with the latest IEE wiring regulations. Approvals BEAB approved. CE marked. Manufactured in the UK in a BS EN ISO 9001:2008, ISO 14001:2004 and BS OHSAS 18001:2007 registered factory. Guarantee Two years product guarantee from date of purchase with on-site service support. Full details are contained in the Installation Instructions supplied with each unit. Installation Speediboil units have hook-on brackets for wall mounting, ideally over a draining board or drip-tray. 150mm clearance should be allowed around the unit for maintenance (refer to instructions). E-MAIL: [email protected] 51 PowerPack Instantaneous Water Heating Instantaneous Water Heater PowerPack is a compact instantaneous water heater. It can supply more than one outlet or spray tap, provided only one outlet tap is used at one time. PowerPack is ideally suited to supplying heated water to a remote area, such as a garage or cloakroom. It can be concealed from view and thus be protected from vandalism. 52 • Available in 7kW and 9kW models. • Ideal for supplying hot water for bedsits, student accommodation and to remote areas. • W hite moulded vandal resistant ABS casing. • H igh temperature cut-out for safety. SPECIFICATION ADVICE: 01603 420128 PowerPack C D B A Dimensions Model A BC D (mm)(mm)(mm)(mm) PowerPack 31 210160 104 Ordering Guide Model Ref. Product Code Rating PowerPack PowerPack 94 050 211 94 050 212 7.0kW @ 240V single phase AC 9.0kW @ 240V single phase AC Specification Controls A pressure differential switch activates the unit when the water flows. Casing Moulded from white ABS. Inner Container Glass reinforced plastic cylinder, complete with inlet/outlet connections and element. A drain plug is fitted to drain the container to prevent freezing if left in winter. Fittings A pressure relief valve set to relieve at 10 bar is provided together with a tee-piece which must be fitted on the cold water inlet. This valve MUST be connected to waste (drain) via a tundish and the drain pipe should fall continuously and be of 22mm bore discharging in a safe visible manner. The pipe must not be reduced in bore or blocked under any circumstances and it should be protected from frost. Safety Feature IPX1 rated. Pressure Range Min: 1 bar. Max: 7 bar. Connections ½" BSP inlet and outlet. Approvals BEAB and Kiwa approved. CE marked. Guarantee Two years. Full details are contained within the Installation Instructions supplied with each unit. E-MAIL: [email protected] Instantaneous Water Heating Technical Specification 53 R Units Combination Storage Wall Mounted Combination Storage R Units are designed to supply hot water for handwashing, dishwashing and general cleaning purposes to cloakrooms, canteens and kitchen areas. Supplied with an integral cold water cistern, they are ideal for installations where the cold feed is from the mains supply but an unvented installation is impractical. R Unit Selection Guide Model Number of Basins R25 R45 R70 R115 2 3 4–5 5–7 Note: These figures are for guidance only and local conditions should be taken into account when sizing the installation. 54 For full details contact our Specification Advice Hotline on 01603 420128 or fax 01603 420229. Suitable for direct connection to the mains water supply. These units are ideal for supplying hot water for multi-outlet applications. The diagram below refers to a typical installation of an R Unit. The pressure at the outlet is determined by the height of the water heater – the higher the unit is mounted above the highest outlet, the greater the pressure. In no circumstances should the base of the water heater be lower than any outlet it is supplying. A typical installation of a Santon R Unit Overflow Heater Basin Basin Basin Basin Cold water supply SPECIFICATION ADVICE: 01603 420128 R Units Technical Specification B Combination Storage C A E D 55 Dimensions ModelCapacity A B C D E Weight(kg) (Ltrs) (mm)(mm)(mm)(mm)(mm) Empty Full R25 R45 R70 R115 25 45 70 115 880452215307680 846610290410647 1055610290410856 1011610445410817 15 21 25 30 45 74 103 153 Ordering Guide Model Ref. Product Code R25 R45 R70 R115 R25 R45 R70 R115 Specification Element A 3.0kW alloy sheathed immersion heater is supplied fitted into the integral 2¼" BSP boss. Thermostat Adjustable from 40°C to 80°C with integral, manually re-settable, over temperature cut-out. Inner Container Copper rectangular tank. Pressure tested to 0.14 bar. The cold water feed tank is built into the top of the outer case and in the following capacities. R25: 4.5 litres, all other models: 8 litres. Supplied complete with ball valve and overflow which can be fitted left or right hand. Casing Substantial gauge sheet steel anti-corrosion treated and finished in stoved enamel. White body and base. Insulation Approved CFC/HCFC free (ODP zero) polyurethane foam. GWP 3.1 (Global Warming Potential). Safety Feature IPX1 rated. Approvals BEAB approved. CE marked. Manufactured in the UK in a BS EN ISO 9001:2008, ISO 14001:2004 and BS OHSAS 18001:2007 registered factory. Connections ½" BSP (male) ball valve / ¾" BSP (male) overflow and hot water outlet. Guarantee Two years. Full details are contained within the Installation Instructions supplied with each unit. E-MAIL: [email protected] Immersion Heaters Immersion Heaters Industrial Electrical Water Heaters 56 Santon is a leading manufacturer of industrial immersion heaters. It supplies elements for use in commercial and industrial environments covering the heating of water, oil and other solutions. Whatever the application, Santon is able to provide the answer. Water Oils Santon manufactures a wide range of immersion heaters for heating water in commercial and industrial environments. Two element sheath materials are supplied to cater for all water conditions – Superloy and Titanium. All Industrial Immersion Heaters are covered by a full 12 month guarantee. These heaters are supplied with a factory-fitted stem type thermostat. Great care needs to be taken when selecting an immersion heater for oil and full details on the oil type, viscosity, etc. should be obtained from the oil manufacturer. Advice should be sought as to the most suitable watts density output rating permissible with the oil. A variety of fixing methods cover all conceivable installations, with loadings from 2.0kW available on a 2¼" BSP head, to 54kW available on a flanged fixing. Applications can vary from car wash machines to industrial calorifiers and swimming pool heaters. For the majority of applications the electrical loading per unit surface area of the immersed heating element is important and a special range designed for use in oil is required. If the correct rating is not used rapid breakdown of the immersion heater can occur with serious consequences to the industrial process concerned. When selecting which immersion heater is required, it is advisable to use the longest element that will fit into the vessel being heated. This ensures that heat dissipation is maximised and keeps the watts density of the element to a minimum, which prolongs element life. SPECIFICATION ADVICE: 01603 420128 Immersion Heaters Immersion Heaters Industrial Electrical Water Heaters Environments Custom Built All Santon heaters are characterised by their ability to withstand the most arduous working conditions and are therefore supplied with terminal enclosures to suit. In the case of the ‘M’ and ‘L’ ranges, the immersion heater cover is manufactured in accordance with IP65. All thermostat pockets are made from Superloy. In a number of applications it is not always possible to fit a standard immersion heater. Our technical department can give expert advice in the specification and design of a heater to suit individual requirements. The following information will help us to specify the optimum method of heating the solution:• Type of fluid to be heated. • Viscosity of fluid (if applicable). • Size of tank. • Lowest initial temperature. • Maximum working temperature. • M aximum permissible length of heater element. • Type of heater fixing required. E-MAIL: [email protected] 57 Immersion Heaters Industrial Electrical Water Heaters / Technical Specification Immersion Heaters Water 2¼" BSPT Fixing Complete With Control Thermostat 58 Loading Model Ref. kW Superloy 2 3 3 4 4 6 6 6 7.5 9 9 9 12 12 18 MY211 MY311 MY330 MY411 MY416 MY616 MY630 MY642 MY724 MY916 MY927 MY936 MY1224 MY1236 MY1836 Model Ref. Phases Titanium - - - - - MT616 - - MT724 - MT927 - - - - Immersed Length (mm) (ins) 1 only 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 3 only 1 or 3 1 or 3 1 or 3 1 or 3 3 only 280 280 760 280 405 405 760 1065 610 405 685 915 610 915 915 11 11 30 11 16 16 30 42 24 16 27 36 24 36 36 Water 2½" BSPT Fixing Complete With Control Thermostat Loading Model Ref. kW Superloy 6 9 12 15 18 LY615 LY920 LY1226 LY1532 LY1838 Model Ref. Phases Titanium - - - - - Immersed Length (mm) (ins) 1 or 3 1 or 3 3 only 3 only 3 only 380 510 660 810 970 15 20 26 32 38 A second pocket is provided to fit a manual reset limit thermostat. Water Bolt-On Fixing Complete With Control Thermostat Loading Model Ref. kW Superloy Model Ref. Phases Titanium 12 DY1216 DT1216 18 DY1816 - 18- DT1823 24 DY2416 - 24- DT2430 24- DT2436 30 DY3027 - 36 DY3627 - 45 DY4527 - 54 DY5436 - Immersed Length (mm) (ins) 3 3 3 3 3 3 3 3 3 3 40516 40516 58523 40516 76030 915 36 685 27 685 27 685 27 91536 These heaters are for horizontal application only. A second pocket is provided to fit a manual reset limit thermostat. Special elements are available for most types of fluids. Please consult our Specification Advice Hotline on 01603 420128 or fax 01603 420229. SPECIFICATION ADVICE: 01603 420128 Immersion Heaters Industrial Electrical Water Heaters / Technical Specification Loading Model Ref. kW Superloy 4.5 6 MGY414 MGY616 Model Ref. Phases Titanium - - Immersed Length (mm) (ins) 1 or 3 1 or 3 355 405 14 16 Oils 2¼" BSPT Fixing Complete With Control Thermostat Loading kW Model Ref. Phases Surface Rating Immersed Length Steel (W/cm²) (W/ins²) (mm) (ins) MO342 MO224 MO336 MO560 MO672 MO112 MO330 MO442 MO548 MO660 3 2 3 5 6 1 3 4 5 6 1 or 3 1 only 1 or 3 1 or 3 1 or 3 1 only 1 or 3 1 or 3 1 or 3 1 or 3 1.4 1.6 1.6 1.6 1.6 1.9 1.9 1.9 1.9 1.9 9 10 10 10 10 12 12 12 12 12 1065 610 915 1525 1830 305 760 1065 1220 1525 42 24 36 60 72 12 30 42 48 60 Note: Heaters with an immersed length over 1.2m (4 feet), require internal support in the vessel to remove strain from the head fixing. Oils 2½" BSPT Fixing Complete With Control Thermostat Loading kW Model Ref. Phases Surface Rating Immersed Length Steel (W/cm²) (W/ins²) (mm) (ins) 2 3 6 1 3 5 6 LO224 LO336 LO672 LO112 LO330 LO548 LO660 1 only 1 or 3 1 or 3 1 only 1 or 3 1 or 3 1 or 3 1.6 1.6 1.6 1.9 1.9 1.9 1.9 10 10 10 12 12 12 12 610 915 1830 305 760 1220 1525 24 36 72 12 30 48 60 Note: Heaters with an immersed length over 1.2m (4 feet), require internal support in the vessel to remove strain from the head fixing. Flanges A range of flanges is available to complement Santon immersion heaters. For MY, MT, MGY and MO type Industrial Immersions 2¼" Universal mechanical flange – ref. F100U 2¼" Blanking plug – ref. F105. For DY and DT type Industrial Immersions Brass flange – ref. F8462. Thermostats Contact our Specification Advice Hotline on 01603 420128 or fax 01603 420229. E-MAIL: [email protected] Immersion Heaters Water 2¼" BSPT Fixing Complete With Cut-Out 59 Useful Information Metric Useful Information Conversion Formulae 60 1 litre = 1000 cu. cm. (61 cu. in.) 1 kg. 0.22 gal. 1.76 pt. 1 kilogram = 2.204lb cubic metre= 1 verage cold Winter 4/7°C A mains water Summer 15/18°C temperature 1000 litres 35.31 cu. ft. 1.31 cu. yd. 1 metre = 39.37 in. 3.28 ft 1.09 yd. 1 sq. metre = 1550.39 sq. in. 10.763 sq. ft. 1.195 sq. yds. Water 10% on freezing expansion 4% on heating due to to 100°C temperature Heating and Electrical Data 1 kilowatt hour (kWh) 1 watt (W) 1 kilowatt hour (kWh) = = = 3,412 British thermal units (Btu) 1 joule per second (1 J/s) 860 kilocalories ne kilocalorie is the amount of heat required to raise 1 litre of water O through 1°C. 1kWh raises 15.5 litres of water through 56°C. Water Heating Calculations kW loading = (litres x temp. rise °C) ÷ (14.3 x time in mins.) Time in mins. = (litres x temp. rise °C) ÷ (14.3 x kW loading) Litres = (14.3 x kW loading x time in mins.) ÷ (temp. rise °C) Temp. rise °C = (14.3 x kW loading x time in mins.) ÷ (litres) Mean Water Temperature in °C (Litres hot x temp. hot °C) + (litres cold x temp. cold °C) Total (hot + cold) litres Temperature Conversion °C = (°F – 32) x 0.555 Capacities of Cylinders and Tanks (Litres) Cylinder Height x dia. (cm²) 1273 Tank length x breadth x height (cm) 1000 Oil Heating Calculations kW loading = litres per hour x temp. rise (°C) 1464 SPECIFICATION ADVICE: 01603 420128 Useful Information Imperial 1 gallon = 277cu. in. (4546 cu. cm.) 10 lb (4.533kg.) 4.54 litres. Average cold Winter 40/45°F mains water Summer 60/65ºF temperature 1 cubic foot= 1 inch = 1 foot = 1 yard = 1 sq. yard = 1 pound = 6.23 gal. 0.028 cu. m 25.4 mm 304.8 mm 914.4 mm 0.836 sq.m 0.4536 kg Water 10% on freezing expansion 4% on heating due to to 212°F temperature Useful Information Conversion Formulae Heating and Electrical Data 1 kilowatt hour (kWh) = 3,412 British thermal units (Btu) One British Thermal unit is the amount of heat required to raise 1 lb of water through 1°F. 1kWh (3,412 Btus) raises 3.41 gallons of water through 100°F Water Heating Calculations kW loading = (gallons x temp. rise °F) ÷ (5.7 x time in mins.) Time in mins. = (gallons x temp. rise °F) ÷ (5.7 x kW loading) Gallons = (5.7 x kW loading x time in mins.) ÷ (temp. rise °F) Temp. rise °F = (5.7 x kW loading x time in mins.) ÷ (gallons) Mean Water Temperature in °C (Gallons hot x temp. hot °C) + (gallons cold x temp. cold °C) Total (hot + cold) gallons Temperature Conversion °F = (°C x 1.7) x 3.2 Capacities of Cylinders and Tanks (Litres) Cylinder Height x dia. (in²) 353 Tank length x breadth x height (in) 277 Oil Heating Calculations kW loading = gallons per hour x temp. rise (°F) 580 E-MAIL: [email protected] 61 Useful Information Recovery Chart Useful Information Approximate time in minutes to heat water through 56°C temperature rise. 62 Litres Loading in kilowatts 11.21.5 2 3 4 67.5 9121518242730364554 5 20161310 7 5 7 28231814 9 7 10 393326201310 15 59493930201510 23 90756045302315 30 118987859393020 34 133 1118967453423 50 196 163 1319866493326 55 1087254362924 68896745363023 80 1057953423526 86 1128456453728 91 1198959484030 100 1319865524433 114 149 11274605037 115 150 11375605038 120 157 11878635239 136 178 133897159443630 144 188 141947563473831 166 217 163 1088772544336 182 238 178 1199579594840 210274206137110 81 69 55 46 227296222148119 99 74 59 49 364 238 190 158 119 95 79 59 455297238198148119 99 74 550359287239179144120 90 80 72 60 48 40 700366305228183152114102 91 76 61 51 900392294235196147131117 98 78 65 1200392313261196174157131104 87 1800 392 294 261 235 196 157 131 2500 408 363 326 272 218 181 3000 392 326 261 218 Suggested Volumes Hot water in litres stored at 71ºC per person/bath/shower Wash basin Spray taps Baths Kitchens Cleaners sinks Dishwashing machines Washing machines Showers Hairdressers: Ladies – per basin per hour Mens – per basin per hour Domestic Commercial 1.1 1.1 to 2.3 - 0.6 to 1.4 5570 3 2.3 to 7 - 9 per day 2 4 20 20 to 60 5 to 9 per min. 9 to 12 per min. - - 36 7 SPECIFICATION ADVICE: 01603 420128 Useful Information Notes 63 E-MAIL: [email protected] heateam is Santon’s very own service division. With us on your side, you can be sure that your customers are in the very best hands. Totally committed to quality and safety, heateam is open 7 days a week, for 363 days a year, and offers: • Dedicated Trade Advice Line – our helpful and qualified specialists are always on hand to help you with even the most complex technical query. • Installer Priority Call-Outs – our 280 strong team of specifically trained expert heating engineers covers the UK, no one is better qualified to look after Santon’s products for the duration of the guarantee. • Fully Stocked Vans – a nationwide fleet of vans, fully stocked with spare parts – meaning we can repair our appliances on the first visit in 95% of call-outs. • Exclusive Service Plans – heateam also offer Santon’s customers a range of exclusive annual service plans. Opening Times: Monday-Friday 8am-6pm, weekends and Bank Holidays* 8.30am-2pm. *excluding Christmas Day and New Year’s Day. Simply call 0844 8711535 or visit our website at www.heateam.co.uk Santon, Hurricane Way, Norwich, Norfolk, NR6 6EA Specification Advice Hotline Tel: 01603 420128 Fax: 01603 420229 E-mail: [email protected] After Sales Service Tel: 0844 871 1530 Fax: 0844 871 1528 E-mail: [email protected] Website www.santon.co.uk The pace of product development is such that we reserve the right to change product specifications without notice. We do, however, strive to ensure that all information in this catalogue is accurate at the time of going to publication. © Santon July 2012 Issue 5 part no. 94 900 006
Similar documents
Santon Aquaheat SS
The new range of Aquaheat SS unvented horizontal and vertical water heaters are available in 50 – 100 litre capacities. Whilst the attractive, modern design makes the Santon water heaters perfect f...
More information