KDL-01 Manual E Rev0102

Transcription

KDL-01 Manual E Rev0102
Data Logger Soft
Ver 3.0
Operating Manual
CONTENTS
Introduction..............................................................................4
System Requirements..............................................................4
Packages.................................................................................5
Notes........................................................................................5
1. Install........................................................................................6
L KDL-01 Instal........................................................................6
L USB-RS232C converter (Option) Install...............................8
L Connect measuring instrument to PC................................10
2. Operate KDL-01.....................................................................11
L KDL-01 Window.................................................................11
L Start KDL-01.......................................................................12
L Setting KDL-01...................................................................13
L Data Transmission and saving...........................................14
L End of KDL-01....................................................................15
3. Uninstall (Remove).................................................................16
L Uninstall KDL-01................................................................16
L Uninstall USB-RS232C Converter cable driver..................18
4. Reference...............................................................................19
L How to search serial port (RS-232C) number; (COM number)..............19
L RN-500 Submenu...............................................................21
L RN-600 Submenu...............................................................21
L Troubleshooting..................................................................22
Introduction
The “Data Logger Soft KDL-01” (=KDL-01) is data logger for any KETT
measuring instruments. The KDL-01 pastes a measurement data by
the KETT measuring instrument on ©Microsoft Excel by the automatic
operation, with the personal computer (=PC) that operates ©Microsoft
Windows 2000 / XP / Vista.
*Please see each operating manual, about the PC operation, the operating
system operation (=“OS”, Microsoft Windows 2000 / XP / Vista), and or the other
software operation (©Microsoft Excel).
*In this operating manual, there are the operations and the illustrations of
Windows XP. Please operate the OS according to an individual manual
excluding the special note, on Windows 2000 and Vista.
*Correspondence Kett products. (May 2009 edition)
[Infrared Moisture Determination Balances FD-720 / FD-610]
[Micro Moisture Analyzer FM-300A]
[Wood Moisture Tester MT-900]
[Paper Moisture Tester HK-300]
[Universal Moisture Tester HB-300]
[Near Infrared Component Analyzer AN-700 / AN-800 / AN-900]
[Coating Thickness Tester L- 200 Series / L- 330 Series]
[Single-grain Rice inspector RN-500 / RN-600]
System Requirements
L OS : Windows 2000 / XP (32bit ) / Vista (32bit)
L PC : Manufacturer supported PC running the above OS (Microsoft
recommended environment), with at least 1 spare USB port (Ver.1.1 or
later) and CD-ROM drives.
L Essential Software : ©Microsoft Excel 2000 / 2002 / 2003 / 2007
Microsoft Corporation recommended operating system requirements.
*If the volume of measurement result data to be handled is large,we recommend
increasing your PC memory.
*The combination of the OS and the essential software will depend on the OS
supporting that software.
4
Packages
Check your KDL-01 Software Package for the following items.
M1×CD-ROM
M1×Operating manual (This book)
M1×PC connection cable
M1×Sub manual (Connect information)
*USB-RS232C converter (Option)
This program has been checked the operation only with serial port (=RS-232C
port) of the PC connecting directly or with the option USB-RS232C converter.
If your PC does not have a connectable RS-232C port directly, please use this
option converter. When other converters are used, we do not guarantee the
operation.
Notes
1. KETT ELECTRIC LABORATORY has the copyright of “KDL-01” and that
hangs to this product and other rights.
2. It is impossible to reproduce by using part or all of this software and the
manual without permission.
3. This software can be installed in one personal computer by single-unit (=one
license). When using it with two or more personal computers, please buy
the license for the number of the personal computer that installs it.
4. The screen and the file composition used in this book might be actually
different.
5. The specification of this software and the content described in the manual
might change without a previous notice in the future.
6. In any case, KETT ELECTRIC LABORATORY does not take responsibility to
your damage which is caused by the introduction and the mistake setting
of this software except defective software, and to the influence which is
caused by using this software and manual.
7. When the customer uses this software that it is not appropriately, or when
the customer uses this software without following the instruction of this
manual, our company doesn't assume the responsibility of the trouble and
any losses.
*The names and logos of Microsoft, Windows, and Excel are either registered
trademarks or trademarks of Microsoft Corporation in United States and other countries.
Other companies and product names are their respective registered trademarks.
5
1. Install
s *If you use the optional USB-RS232C converter, please do not connect the
Note
USB-RS232C converter with PC until the driver's installation is completed.
*Please operate the installation software with log on manager’s group account.
(Recommend; account of administrator's group)
*If the dialog “User account control (Vista)” or “Install program as other user
(2000/XP)” is displayed while install operation, the installation cannot be
completed even if the information is input. First of all, log off from PC, and try
to reinstall after log on by the manager’s account.
LKDL-01 Install
1. Startup Windows.
2. Insert the KDL-01 CD-ROM.
*It is necessary to end all other applications.
3. D o u b l e c l i c k [ C D d r i v e ] i n “ M y
Computer”.
4. Click [SetupKDL].
6
5. Click [Next] on “SetupKDL” dialog.
6. Click [Next].
*When you will install to different folder,
you can change to different folder.
7. Click [Next].
*When you need shortcut on desktop,
click checkbox to cheku on.
8. Click [Finish].
7
L USB-RS232C converter (Option) Install
Install the “USB-RS232C converter driver” using the following method.
s
Note
* When the computer has RS-232C port of connecting directly, it is not neces-
sary to install it.
1. Double click [CD drive] in “My
Computer”.
2. Double click [SETUP] in “UCT_driver”
folder.
3. Click [Next].
8
4. Click [Next].
5. Click [Finish].
*Please restart your PC before using.
9
L Connect measuring instrument to PC.
As for the connection of the measuring instrument and PC, the connection
method is different according to the measuring instrument.
Please see the attached paper “Connecting the measuring instrument to your
computer”.
s
Note
* When the PC does not have any RS-232C port, the optional USB-RS232C
converter is necessary for our specifications.
L Connect USB-RS232C converter : first time
* When you connect first time, please operate the installation software with log on
manager’s group account. (Recommend; account of administrator's group)
* If you connect the option USB-RS232C converter to your PC before installing
the driver, a dialog will be displayed requesting you to install the driver. Please,
disconnect the USB-RS232C converter and install the driver first.
(See P.8 [ L USB-RS232C converter (Option) Install])
*The following dialogs are displayed when the converter is connected, first time.
And the installation work makes progress by the automatic operation.
The RS-232C port number is display according to OS that operates by your PC,
please remember the displayed the serial port number.
* Refer to look up at the RS-232C port number to P.19.
10
2. Operate KDL-01
L KDL-01 Window
function button A
status bar A
Button name
Function
Open
Open the excel file. (New excel file or past excel
file of measurement result saved.)
function button
Rev
Click [Rev], and receive measurement data.
With AN-800 / RN-500 / RN-600, Click [Rev] and
measurement start automatically.
Stop
Receiving cancel.
Save
Save the excel file.
Set
Select the measuring instrument and RS-232C Port.
Exit
Exit KDL-01
L Status bar
RS-232C port (=com port) Number and the name of KETT measuring instrument that
has been selected is displayed here.
11
L Start KDL-01
*The measuring instrument and PC are
connected by using the connecting
cable, beforehand . (Please see the attached paper
“Connecting the measuring instrument
to your computer”.)
*Please set beforehand when the PC
connection setup is necessary in the
connected measuring instrument.
(Please see the earch operating
manual of measuring instrument.)
1. T u r n o n y o u r P C a n d s t a r t u p
Windows.
2. Double Click ( ) KDLExcel on
desktop.
*If no shortcut on desktop, click
→ [KETT] → [KDLExcel] on program
group.
12
L Setting KDL-01
1. Click [Set].
KETT PRODUCT TYPE
The measuring instrument connected
with PC.
COMMUNICATION PORT
Communication port (Com) number
with the connecting cable.
*Refer to look up at the RS-232C port
number to P.19.
2. Click [OK].
13
L Data Transmission and saving
1. Click [Open].
2. I f “ E X C E L f i l e o p e n O r n e w
creation” dialog is displayed, select
an existing file or input the new
filename, and click [Open].
*Please, separate excel file on each
measuring instrument.
14
3. If [Rev]
is clicked, it becomes
possible the data reception from the
measuring instrument.
*W h e n [ R e v ] i s c l i c k e d , A N - 8 0 0 ,
RN-500, and RN-600 begin the
measurement of the automatic
operation.
4. When the measuring data is received
from the measuring instrument, it is
output to the excel work-sheet by the
automatic operation.
*When the reception is canceled, click
[Stop].
L End of KDL-01
Click [Exit].
15
3. Uninstall (Remove)
s *Please operate the installation software with log on manager’s group account.
Note
(Recommend; account of administrator’s group)
*If “uninstall” cannot be selected, or the dialog “User account control (Vista)”
is displayed while uninstall operation, the uninstallation cannot be completed
even if the information is input. First of all, log off from PC, and try to log on
by the manager’s account.
■Uninstall KDL-01
s
Note
*We will recommend the backup of the measurement data etc. to be reserved
before this operation.
1. Select [Control Panel] in start menu.
*If you operate Windows 2000, please
select [start]→[settings]→[Control
Panel]
2. D o u b l e c l i c k [ A d d o r R e m o v e
Programs].
*If you operate Windows 2000, please
select [Add / Remove Programs]. If you
operate Windows Vista, please select
[Programs and Features].
16
3. Select [KETT KDL-01], and click
[Remove].
*If you operate Windows Vista, please
select [KETT KDL-01], and click
[Uninstall/Change]
4. Click [Yes].
5. Click [Close].
17
■Uninstall USB-RS232C Converter cable driver
1. Please operate same operation from
P.16 (1) to (2).
2. Click [U232 P9/P25 V7.2.98] and
Click [Remove].
*If you operate Windows Vista, please
select [U232 P9/P25 V7.2.98], and
click [Uninstall].
3. Click [OK].
4. Click [Finish].
18
4. Reference
■How to search serial port (RS-232C) number; (COM number)
1. Select [Control Panel] in start menu.
*If you operate Windows 2000, please
select [start]→[settings]→[Control
Panel].
2. Double click [System].
*Please make the control panel not the
category view but a classic view on
Windows XP and Windows Vista.
3. Click [Device Manager].
19
4. In a right example, the direct connect
RS-232C port is one, because it
is displayed [Communication Port
(COM1)].
And, the RS-232C port of USBRS232C converter is four, because
it is displayed [Serial On USB Port
(COM4)].
*T h e n a m e o f t h e U S B - R S 2 3 2 C
conversion cable (option) is “Serial On
USB Port”. When (
) is here, the
installation is not correctly completed
or the configuration file is broken. Try to
see “P.8”, and to install it again.
20
L RN-500 Submenu
The kind of the data put on Excel
can be selected when connecting
with RN-500. It right-clicks on the
KDL window, and selects it while
having been displayed.
*The setting of RN-500 cannot be
changed from KDL.
L RN-600 Submenu
1. The content of RN-600 set can be
confirmed. It right-clicks on the
KDL window, and “RN-600 setting
information” is selected. *The setting of RN-600 cannot be
changed from KDL. 2. The kind of the data put on Excel
can be selected when connecting
with RN-600. It right-clicks on the
KDL window, and selects it while
having been displayed.
21
L Troubleshooting
Trouble
Check Point
1. P l e a s e c o n f i r m w h e t h e r
the selected RS-232C ports
corresponding to the connected
port. (See P.19)
Data is not putted on EXCEL.
or
2. P l e a s e c o n f i r m w h e t h e r P C
is connected to measureing
instrument connecting cable.
or
3. Please confirm whether the kind
of the connecting cable is suitable
for the connected measuring
instrument.
22
1002・PA・0102・050