SKB
Transcription
SKB
Unit Coolers SKB 4 kW 30,5 kW www.friga-bohn.com SKB range unit coolers are suitable for chilling or low temperature storage applications. 24 basic models with capacities ranging from 4 to 30.5 kW. NOMENCLATURE ... SKB 19 R Unit cooler SKB Fin spacing Model DESCRIPTION ... HIGH PERFORMANCE HEAT EXCHANGER • The highly efficient and compact SKB range finned coils are designed with corrugated surface aluminium fins (fin spacing 4.23 or 6.35 mm) and grooved internal structure copper tubes. • The refrigerant distributors are nozzle type (nozzle factory fitted). VENTILATION • The SKB unit cooler line is equipped with propeller type fan assemblies, Ø 450 mm, 4 P = 1500 r.p.m., 230-400 V, 3 phase, 50 Hz, IP 54, class F, requiring no routine maintenance, with built-in thermal-overload protection which must be connected externally to effect warranty. • The high-output, profiled blades operate at a very low noise level. • The fan guards conform to NF E51 190 standard. • The option 2V5 offers a low-speed possibility which is ideal for applications with major noise limitation requirements. Refer to the chart on correction to select a unit wired for low-speed operation. DEFROST • The tubular electric heaters are fitted into pipes expanded in the finned block. • One of these heaters is fixed under the intermediate drain pan, thus insuring equal heat distribution for a quick and efficient defrost. • The heaters are factory wired to a terminal block and coupled 400 V 3 phase. • Possibility of coupling 230 V 3 phase or 230 V 1 phase. • Defrost water is collected in the intermediate drain pan then drained through a large drain fitting (Ø 1” G). CASING OPTIONS ... Coil BYP BAE WCO DCF Polual Blygold coating of the fins: SKB-R and SKB-L. Coating of the fins: SKB-R and SKB-L (except 4 fan units). Glycol water and brine. Dual circuit hot/cold. Motorfans RFA 2V5 MM5 MP5 M60 CMU Streamer. 2 speed 400 V 50 Hz fan assembly. Single phase 230 V 50 Hz fan assembly*. 400 V 50 Hz aerofoil fan*. 230/400 V 60 Hz three phase fan assembly. Factory wiring. • An aesthetic white enamelled galvanized steel sheet casing allows for easy cleaning of the unit. • SKB-E and SKB- C are equipped with an internal drain pan which limits condensation. • The easily removable side panels and the hinged external drain pan allow for easy access to the components of the evaporator (coil, fan assemblies, heater elements, connections…). • The hinging system allows the drain pan to be taken off. Defrost Certifications Miscellanous E U R O V E N T CERTIFIED PERFORMANCE CERTIFY ALL DX AIR COOLERS AIR COOLED CONDENSERS DRY COOLERS RVU HG1 HGT RCS VGT E U R O V E N T CERTIFIED CER TIFIED PERFORMANCE Peripheral heaters. Hot gas (coil: hot gas, drain pan: electrical heaters). Hot gas (coil and drain pan). Electrical heaters on air discharge*. Flange of textile duct with guard for aerofoil fan*. Kit CERTIFY CER TIFY ALL DX AIR COOLERS AIR COOLED CONDENSERS DRY DR Y COOLERS EUROVENT : The performance published of our products are certified in conformity with european standards EN328. ISO 9001 : Our company is certified by LRQA to comply with quality standards ISO 9001 : 2000. RoHS - WEEE : Our products are compliant with regards to european guideline 2002/95/CE and 2002/96/CE concerning electric and enlectronic components.. CE : Our products are in conformity with european guidelines. GOST : Products in conformity with "GOST" agreement. Sound power level Lw D : Delta Y : Star dB(A) dB(A) 1 fan 2 fans 3 fans 4 fans 80 77 83 80 85 82 86 83 62 RVK ELK E1K THD THS 2TH Peripheral heaters. SKB-R and SKB-L: full electrical defrosting (5 coil heaters + 1 drain pan heater). • SKB-R and SKB-L: light electrical defrosting (3 coil heaters). • SKB-E and SKB-C: renforced electrical defrosting (3 additional heaters in the coil). Defrost control thermostat (5709L). Safety thermostat (5708L). Defrost control and safety thermostat (5709L + 5708L). Other options Please, consult us. * Specific casing and fan guard(s). TECHNICAL DATA ... tA1 SKB ... R +10 + E1K +2 -5 -10 -25°C SKB ... R 4,23 mm SKB ... R Models DT1 = 8K - SC 2 (1) Capacity - R404A Surface 06 10 12 16 19 24 kW 7,62 13,17 15,77 19,87 23,51 30,48 m2 28,5 38 57 57 86 105 Circuit volume dm3 4,85 6,57 9,69 9,58 14,36 17,48 Air flow m3/h 3800 8200 7600 12300 11400 14800 m 16 18 18 20 20 22 Num. 1 2 2 3 3 4 W max 1 x 499 2 x 499 2 x 499 3 x 499 3 x 499 4 x 499 Air throw Fan 400 V/3/50 Hz 1500 r.p.m. Ø 450 mm 400V/3/50Hz Electric defrost ELK (3) A max (2) 1x1 2x1 2x1 3x1 3x1 4x1 W total 2100 3000 4200 4200 6000 7200 400 V/3 Electric defrost E1K (3) 400 V/3 A total 3,19 4,56 6,38 6,38 9,12 10,94 W total 1050 1500 2100 2100 3000 3600 A total 1,56 2,28 3,19 3,19 4,56 5,47 kg 54 92 102 118 135 152 D 5/8” D 1 1/8" D 1 1/8" D 1 1/8" D 1 1/8" D 1 5/8" 7/8” 1 3/8" 1 3/8" 1 5/8" 1 5/8" 1 5/8" Net weight Ø (4) Inlet Connections Ø ODF (5) Outlet (1) See pages “APPENDIX” (2) Setting of overload protections. For room temperatures ‘ti’ other than +20 °C, multiply the given amperage by the ratio 293/(273 + ‘ti’) so as to obtain the approximate amperage after the room pull down. (3) Electric defrost option. (4) Liquid distributor: male to be brazed (5) ODF: female sweat type connection = = = 652 650 343 309 343 25 x 15 = 1302 494 309 641 641 283 mm = = = 1000 = 1000 1061 = = 1201 318 309 650 464 102 = 1201 600 600 600 284 643 645 650 600 mini = 1952 343 G 1" 45 1711 = 1345,5 = 1000 1465,5 1000 2361 2811 Average correction factors for standard motors connections in Y instead of D (2V5 option) 06 10 12 16 19 24 Capacity SKB ... R 0,84 0,85 0,84 0,85 0,84 0,83 Air flow 0,76 0,77 0,76 0,77 0,76 0,76 Air throw 0,76 0,76 0,76 0,76 0,76 0,76 Models DT1 = 8K - SC 2 OPTIONS ... BYP BAE WCO DCF RFA 2V5 MM5 MP5 M60 CMU RVU HG1 HGT RCS VGT RVK ELK E1K THD THS 2TH SKB ... R O O O O O O O O O O 63 O O - O O O O O O O O TECHNICAL DATA ... tA1 SKB ... L +10 + E1K +2 -5 -10 -25°C SKB ... L 6,35 mm Models Capacity - R404A Glycol water* Surface Circuit volume Air flow DT1 = 8K - SC 2 (1) DT1 = 8K - SC 2 (1) Air throw Ø 450 mm Fan 400 V/3/50 Hz 1500 r.p.m. 400V/3/50Hz Electric defrost ELK (3) 400 V/3 Electric defrost E1K (3) 400 V/3 Net weight Inlet Outlet Connections SKB ... L kW kW m2 dm3 m3/h m Num. W max A max (2) W total A total W total A total kg Ø (4) Ø ODF (5) 06 09 11 14 18 22 6,56 19,5 4,85 4000 16 1 1 x 499 1x1 2100 3,19 1050 1,56 53 D 5/8" 7/8” 10,42 26 6,57 8600 18 2 2 x 499 2x1 3000 4,56 1500 2,28 92 D 7/8" 1 1/8" 13,43 13,04 39 9,69 8000 18 2 2 x 499 2x1 4200 6,38 2100 3,19 102 D 1 1/8" 1 3/8" 15,54 39 9,58 12900 20 3 3 x 499 3x1 4200 6,38 2100 3,19 118 D 1 1/8" 1 3/8" 20,14 17,07 60 14,36 12000 20 3 3 x 499 3x1 6000 9,12 3000 4,56 135 D 1 1/8" 1 5/8" 25,92 26,21 73 17,48 15600 22 4 4 x 499 4x1 7200 10,94 3600 5,47 152 D 1 5/8" 1 5/8" (1) See pages “APPENDIX” (2) Setting of overload protections. For room temperatures ‘ti’ other than +20 °C, multiply the given amperage by the ratio 293/(273 + ‘ti’) so as to obtain the approximate amperage after the room pull down. (3) Electric defrost option. (4) Liquid distributor: male to be brazed (5) ODF: female sweat type connection = = = 652 650 343 25 x 15 = 1302 309 343 Glycol water : Fluid : Percentage of glycol = 30 % - Fluid inlet temperature = - 8° C - Fluid outlet temperature = - 4° C Air : Dry airinlet temperature = + 2° C - Relative humidity = 85 % Other conditions: please consult us. 494 309 641 641 283 mm = = = 1000 = 1000 1061 = = 1201 318 309 650 464 102 = 1201 600 600 600 284 643 645 650 600 mini = 1952 343 G 1" 45 1711 = 1345,5 = 1000 1465,5 1000 2361 2811 Average correction factors for standard motors connections in Y instead of D (2V5 option) SKB ... L Models Capacity Air flow Air throw Capacity Air flow Air throw DT1 = 8K - SC 2 Glycol water* DT1 = 8K - SC 2 06 09 11 14 18 22 0,83 0,77 0,76 - 0,85 0,77 0,76 - 0,83 0,77 0,76 0,88 0,77 0,76 0,85 0,77 0,76 - 0,83 0,77 0,76 0,88 0,77 0,76 0,84 0,76 0,76 0,89 0,76 0,76 OPTIONS ... BYP BAE WCO DCF RFA 2V5 MM5 MP5 M60 CMU RVU HG1 HGT RCS VGT RVK ELK E1K THD THS 2TH SKB ... L O O O O O O O O O O O 64 O - O O O O O O O O TECHNICAL DATA ... tA1 SKB ... E +10 +2 -5 -10 -25°C SKB ... E 4,23 mm SKB ... E 06 09 11 13 16 21 kW kW m2 dm3 m3/h m Num. W max A max (2) Num. Num. W total A total W total A total kg Ø (4) Ø ODF (5) 6,15 4,86 28,5 4,92 3800 16 1 1 x 499 1x1 5 1 2100 3,19 1050 1,56 55 D 7/8” 1 1/8" 10,11 8,00 38 6,71 8200 18 2 2 x 499 2x1 5 1 3000 4,56 1500 2,28 93 D 1 1/8" 1 3/8" 12,56 10,00 57 9,84 7600 18 2 2 x 499 2x1 5 1 4200 6,38 2100 3,19 103 D 1 1/8" 1 5/8" 15,29 12,09 57 9,92 12300 20 3 3 x 499 3x1 5 1 4200 6,38 2100 3,19 119 D 1 1/8" 1 5/8" 18,95 15,13 86 14,55 11400 20 3 3 x 499 3x1 5 1 6000 9,12 3000 4,56 136 D 1 5/8" 1 5/8" 23,47 18,59 105 18,83 14800 22 4 4 x 499 4x1 5 1 7200 10,94 3600 5,47 157 D 1 5/8" 2 1/8" Models DT1 = 7K - SC 3 (1) DT1 = 6K - SC 4 (1) Capacity - R404A Surface Circuit volume Air flow Air throw Ø 450 mm Fan 400 V/3/50 Hz 1500 r.p.m. 400V/3/50Hz Coil Drain pan Electric defrost 400 V/3 Electric defrost E1K (3) 400 V/3 Net weight Inlet Outlet Connections (1) See pages “APPENDIX” (2) Setting of overload protections. For room temperatures ‘ti’ other than +20 °C, multiply the given amperage by the ratio 293/(273 + ‘ti’) so as to obtain the approximate amperage after the room pull down. (3) Electric defrost option. (4) Liquid distributor: male to be brazed (5) ODF: female sweat type connection = = = 652 650 343 309 343 25 x 15 = 1302 494 309 641 641 283 mm = = = 1000 = 1000 1061 = = 1201 318 309 650 464 102 = 1201 600 600 600 284 643 645 650 600 mini = 1952 343 G 1" 45 1711 = 1345,5 = 1000 1465,5 1000 2361 2811 Average correction factors for standard motors connections in Y instead of D (2V5 option) SKB ... E Models Capacity Air flow Air throw Capacity Air flow Air throw DT1 = 7K - SC 3 DT1 = 6K - SC 4 06 09 11 13 16 21 0,84 0,76 0,76 0,85 0,76 0,76 0,86 0,77 0,76 0,87 0,77 0,76 0,84 0,76 0,76 0,85 0,76 0,76 0,86 0,77 0,76 0,87 0,77 0,76 0,84 0,76 0,76 0,85 0,76 0,76 0,84 0,76 0,76 0,85 0,76 0,76 OPTIONS ... BYP BAE WCO DCF RFA 2V5 MM5 MP5 M60 CMU RVU HG1 HGT RCS VGT RVK ELK E1K THD THS 2TH SKB ... E - - O O O O O O O O 65 O O O O O O - O O O O TECHNICAL DATA ... tA1 SKB ... C +10 +2 -5 -10 -25°C SKB ... C 6,35 mm SKB ... C 05 08 10 12 15 19 kW kW m2 dm3 m3/h m Num. W max A max (2) Num. Num. W total A total W total A total kg Ø (4) Ø ODF (5) 5,24 4,17 19,5 4,92 4000 16 1 1 x 499 1x1 5 1 2100 3,19 1050 1,56 54 D 7/8” 1 1/8" 8,05 6,63 26 6,71 8600 18 2 2 x 499 2x1 5 1 3000 4,56 1500 2,28 93 D 1 1/8" 1 3/8" 10,65 8,53 39 9,84 8000 18 2 2 x 499 2x1 5 1 4200 6,38 2100 3,19 103 D 1 1/8" 1 5/8" 12,38 9,87 39 9,92 12900 20 3 3 x 499 3x1 5 1 4200 6,38 2100 3,19 119 D 1 1/8" 1 5/8" 16,09 12,89 60 14,55 12000 20 3 3 x 499 3x1 5 1 6000 9,12 3000 4,56 136 D 1 5/8" 1 5/8" 20,17 16,07 73 18,83 15600 22 4 4 x 499 4x1 5 1 7200 10,94 3600 5,47 157 D 1 5/8" 2 1/8" Models DT1 = 7K - SC 3 (1) DT1 = 6K - SC 4 (1) Capacity - R404A Surface Circuit volume Air flow Air throw Ø 450 mm Fan 400 V/3/50 Hz 1500 r.p.m. 400V/3/50Hz Coil Drain pan Electric defrost 400 V/3 Electric defrost E1K (3) 400 V/3 Net weight Inlet Outlet Connections (1) See pages “APPENDIX” (2) Setting of overload protections. For room temperatures ‘ti’ other than +20 °C, multiply the given amperage by the ratio 293/(273 + ‘ti’) so as to obtain the approximate amperage after the room pull down. (3) Electric defrost option. (4) Liquid distributor: male to be brazed (5) ODF: female sweat type connection = = = 652 309 343 25 x 15 = 1302 650 343 494 309 641 641 283 mm = = = 1000 = 1000 1061 = = 1201 318 309 650 464 102 = 1201 600 600 600 284 643 645 650 600 mini = 1952 343 G 1" 45 1711 = 1345,5 = 1000 1465,5 1000 2361 2811 Average correction factors for standard motors connections in Y instead of D (2V5 option) SKB ... C Models Capacity Air flow Air throw Capacity Air flow Air throw DT1 = 7K - SC 3 DT1 = 6K - SC 4 05 08 10 12 15 19 0,84 0,77 0,76 0,84 0,77 0,76 0,85 0,77 0,76 0,86 0,77 0,76 0,84 0,77 0,76 0,84 0,77 0,76 0,85 0,77 0,76 0,86 0,77 0,76 0,84 0,77 0,76 0,84 0,77 0,76 0,85 0,76 0,76 0,86 0,76 0,76 OPTIONS ... BYP BAE WCO DCF RFA 2V5 MM5 MP5 M60 CMU RVU HG1 HGT RCS VGT RVK ELK E1K THD THS 2TH SKB ... C - - O O O O O O O O O 66 O O O O O - O O O O
Similar documents
information in PDF file More information in PDF file
with drain holes, IP54, class F, including overload protector for field wiring. Fans Ø 450 mm fitted with plastic guards, fans Ø 400 mm fitted with plastic coated steel wire guards. • Guard design ...
More information