= low water = faster radiator = lower consumption = greater comfort
Transcription
= low water = faster radiator = lower consumption = greater comfort
tia, The lower the iner gy consumption the lower the ener As a result of improved insulation techniques, heating systems need to supply less energy. Knockonwood warm power, noble wood rmined by The “inertia” is dete t and weight the water conten Tempo warm power, basic style Lengths: 16” → 118” Heights: 8” → 36” Depths: 5”, 6”, 8” 1930 Water content → Weight → Reaction time → 1960 6.6 Gal (25 L) 176 lbs (80 kg) very slow 1980 3.1 Gal (12 L) 88 lbs (40 kg) very slow 1995 3.1 Gal (12 L) 66 lbs (30 kg) slow 0.26 Gal (1 L) 6.6 lbs (3 kg) very fast Low-H2O means literally ‘low water’ content. The low water content means that the radiator can react very fast to demand. Low-H2O radiators have been tested in Great Britain and the fuel savings run to at least 12% Lengths: 24” → 87” Heights: 12”, 22”, 38” Depths: 3” → 6” ANTI Lengths: 20” → 110” Heights: 14” → 38” Depths: 4”, 6”, 8” G ENT AR G LA WISSE Lengths: 23.6” → 47.2” Heights: 14, 19.5”, 25.5” Depths: 5 1/8”, 7 3/32”, 9 1/16” Lengths: 20” → 110” Heights: 8” → 38” Depths: 4”, 5”, 6”, 8” TE warm power, slim line 30 YEAR E ELEM Linea Plus WARM Playful warmth, colorful comfort warm power, cutting-edge design E Play strada RANTE FI N T 30 l heat emitters, The most powerfu R es JAA ur er temperat ideal for low wat UA E AR UB = low water = faster radiator = lower consumption = greater comfort Modern heating has to respond quickly and safely to all temperature changes, allowing you to benefit from extra heat sources without having to pay for it. °F Brass collectors with 1/2” connections With dirt-repellent and dust-proof lacquer in graphite grey Up to 16 parallel copper tubes for the best heat emission 55 Corregated aluminum fins per foot for super heat-output at low water temperatures healthy heating Causes of burns mini strikingly discreet °F 155 (°C) (70) 145 (65) 135 Lengths: 23.5” → 118” Heights: 3 5/32” → 9 1/16” Depths: 2”, 4”, 6”, 8” 125 partial thickness burns full thickness burns (60) Traditional radiator (55) (50) Basic 115 (45) SAFETY LIMIT 109°F (43°C) warm power, timeless design 105 (40) Low-H2O elements 95 (35) safety contact temperature seconds Lengths:20” → 110” Heights: 13”, 23”, 29” Depths: 4”, 6”, 8” ed Perfectly controll room temperature Reaction time mini Canal 73.4°F (23°C) Minimal recess depth, 71.6°F (22°C) Lengths: 18” → 10’ Heights: 6” → 16” Depths: 4” → 8” 69.8°F (21°C) tempo warm power, basic style 68°F (20°C) 64.4°F (18°C) builD-in wall warm power, extra strong Lengths: 25” → 80” Heights: 18”, 23, 29” Depths: 4”, 6”, 8” Traditional Radiator 68°F (20°C) Lengths:15.5” → 118” Heights: 8”, 12”, 15.5”, 19.5” Depths: 4”, 6”, 8” Maxi Jaga Low-H2O 71.6°F (22°C) The perfect partne r for rADIANT heat ing 0 2 4 6 warm power, invisibly packed 71.6°F (22°C) Lengths: 15.5” → 118” Heights: 8” → 35.5” Depths: 4 41⁄64”, 6 39⁄64”, 8 37⁄64” 68°F (20°C) Room temperature with floor heating 64.4°F (18°C) Room temperature with Jaga Low-H2O + floor heating Energy saving 0 2 4 6 8 10 12 14 16 18 20 22 24 Jaga Low-H2O radiators react very fast and can be easily controlled. By contrast, radiant heating reacts slowly. For ultimate heating comfort, radiant heating should be combined with Low-H2O radiators. 8 1 same size, 3 times th e heating output The best solution for heat pumps, solar energy and all systems running wih extremely low water temperatures as low as 95°F. briza Best of both world Heating, cooling, ventilation Ultra-slender, super-powerful s The best static heating system linked to a new intelligent dynamic engine. Lengths: 72 → 152 cm Heights: 65 cm Depths: 14.7 cm Watt verwarming: van 1974 tot 8677 Watt koeling totaal van 630 tot 2961 Watt koeling voelbaar van 517 tot 2463 Extremely low nois tic control Intelligent automa DBE’s sensors constantly measure the temperature in the room and that of the water in the radiator. consumption: Electrical power andby less than a tv in st e level Say goodbye to the noisy fan coil units. DBE fans operate with a sound level of 30Db. side yo invisibly built-in in ur Low-H2 O radiat or 14.5 cm Knockonwood mini Canal DBE Minimal recess depth, maximum heat Heights: 14.5 cm Depths: 26 → 42 cm Lengths: 110 → 310 cm Watt: van 1085 tot 6857 Strada Linea Plus Tempo Maxi clima Canal Complete climate control: heating, cooling, ventilation Lengths: 57 → 177 cm Heights: 8.5 → 13 cm Watt verwarming: van 800 tot 3200 Watt koeling (totaal): van 320 tot 1280 2 CO rolled cont The benefits: DBE unit EfFIcient the perfect indoor atmosphere everywhere, all the time Intelligent measures the air quality and cuts in itself when needed 6 cm micro Canal The smallest underfloor unit Attractive discreetly built in to your Low-H2O radiators Comfortable draught free and quiet Healthy no central supply ducts to get dirty but instead direct admission of air to each room Money saving controlled by room, no unnecessary ventilation User-friendly Lengths: 60 → 200 cm Heights: 6 → 8 cm Watt: van 390 tot 1950 simple operation by room or centrally controlled for the entire zone or building O RADIATOR THE LOW-H2 HS THAT BREAT Play
Similar documents
Save - Jaga
the soya harvest now has a new lease of life in this organic radiator. Vertiga is the first combination of Energy Savers, Eyecatchers and Top Performers. A brand new design radiator for extremely l...
More information