algonix by medilab - Medicina Biol gica
Transcription
algonix by medilab - Medicina Biol gica
USER MANUAL algonix by medilab NON-INVASIVE PAIN THERAPY Version 5-ENG; 04-08 m e d i l a b __________________________________________________________________ Table of Content Table of Content .................................................................................................................................... 2 Notes ....................................................................................................................................................... 3 Batteries ............................................................................................................................................................. 3 Introduction ........................................................................................................................................... 4 Indications.............................................................................................................................................. 5 algonix by medilab console ................................................................................................................... 6 Control panel on the front................................................................................................................................. 6 Back of the console............................................................................................................................................ 7 Preparing the patient for the treatment .............................................................................................. 8 Preparing the algonix by medilab system for treatment.................................................................... 9 Treatment............................................................................................................................................. 14 The user interface during the treatment:........................................................................................................ 17 Using the markers ............................................................................................................................... 18 Probes and electrolyte ......................................................................................................................... 20 Probes .............................................................................................................................................................. 20 Differentiation of probes ............................................................................................................................ 21 Electrolyte ........................................................................................................................................................ 22 Why CEL 144 is obligatory........................................................................................................................ 23 Appendix A – List of Programs in the “Clinical Index Status” ...................................................... 24 Appendix B – Guidelines for algonix treatments.............................................................................. 25 _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 2- m e d i l a b __________________________________________________________________ Notes 1. Keep this manual for further consultation. 2. After unpacking, check, if the equipment is intact. In particular the equipment must not present visible damages caused by transportation. In case of doubt do not use the equipment and contact qualified personnel. 3. Before plugging the input lead please check the cable connections of the accessories. 4. If the electric outlet does not match the plug, ask qualified personnel to change the plug. 5. This equipment must be used only according to its own characteristics. Every different use is inappropriate and dangerous. The manufacturer cannot be considered responsible for any damages caused by improper use. 6. In case of damage and/or bad functioning, immediately turn off the equipment and do not touch it. Please contact the manufacturer for check and repair. Use only original spare parts in order to grant equipment security. 7. Only people who have completed appropriate training on the algonix by medilab device are authorized to operate the system. 8. Contraindications for algonix by medilab treatments are pregnancy and pacemaker. Data recording for patients monitored with Halter equipments (24 hours monitors) can be distorted. 9. To clean the surface of the device only use a damp cloth. Do not use volatile liquids such as solvents, benzene, alcohol, acetone or other chemical detergents. 10. The algonix by medilab device has to undergo technical maintenance at least every two years. 11. Do not put the equipment into water Batteries algonix by medilab works with rechargeable batteries. Please keep in mind: 1. New batteries perform best after 2 or 3 recharges 2. Using the batteries will exhaust them, even if they can be charged hundreds of times 3. Do not use batteries for usages different from the suggested ones 4. Do not use damaged or torn battery chargers 5. Do not short circuit batteries 6. Do not leave batteries in hot or cold rooms since their capacity and life span will be affected. 7. Batteries should be stored between 15°C and 25°C (59°F and 77°F). 8. Do not throw batteries into fire! 9. Do not dispose of batteries with the normal waste! _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 3- m e d i l a b __________________________________________________________________ Introduction algonix by medilab is the latest innovation of the most advanced technology in pain management, injury and trauma rehabilitation representing two decades of biomedical design and engineering. It is designed for precise treatment of the most difficult injury and trauma cases facing today’s clinician, including a wide variety of muscle and connective tissue problems. There are many different disciplines in the vast field of electro-physical technology. Their conjunctive relationship is the natural electrical current operating within the body. The difference between each discipline is the method of approach to the body with respect to the administration of current. algonix by medilab analyses the bioelectrical condition of the treated tissue areas and conducts a pain and trauma therapy by means of a biocybernetic process. algonix by medilab is not only a term, but a technology that grew out of the expansive field of neurophysiology. Modern medical science acknowledges multiple processes in the body that are electrical. Every cell in the body can be seen as an “electrical generator” which generates electrical currents. These currents are measured often in the skin (EDR), the brain (EEG), the heart (EKG), and the muscles (EMG). The algonix by medilab technology works hand in hand with these currents. algonix by medilab stimulates the production of Adenosine Triphosphate (ATP), which is stored cellular energy that allows a cell to function. This in turn triggers the body’s natural bio-chemical healing process. This process allows intracellular fluids to be restored, electrolyte levels to be replenished and nutrients to be absorbed. algonix by medilab further stimulates intracellular calcium which strengthens the cellular balance and healing. Amino acid transport is increased, as well as protein synthesis, which assists in tissue repair. Blood circulation and lymphatic flow are boosted. These vital functions are increased five fold with this technology to promote optimum healing and regeneration of cells and tissue. algonix by medilab thus speeds up the repair of tendons and bones, the edema absorption and the repair of tissue wounds with anti-bacteria effects. algonix by medilab uses a very low amperage current, it works with between 35 to 600 µA (millionth ampere). Usually the patient does not feel any pain during the treatment with algonix by medilab. The operator uses the equipment with specifically designed and included probes. Adopted for muscle reeducation, the algonix by medilab technology also allows physicians to tone and lift up face and body muscles. Furthermore, pre- and post-operation treatments permit a quicker recovery (up to 100% quicker than normally) and, according to different situations, scars and inflammations will be considerably reduced. _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 4- m e d i l a b __________________________________________________________________ Indications algonix by medilab can be used for: Treatment of pre- and post-surgery pain Prolonged treatments for pain caused by chronic pathologies Treatment of intense pathologies _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 5- m e d i l a b __________________________________________________________________ algonix by medilab console Control panel on the front Non-wired inputs (not in use at present) Power switch Unipolar outputs (channel 1-3) Reset switch Start button for starting treatment Analogue input panel (not in use at present) Trigger inputs Unipolar outputs (channel 1-3) These output ports must be used for all probes without trigger. Jacks from red panel (left): active ports Jacks from blue panel (right): neutral ports Use neutral ports (jacks from blue panel) with REMOTE 1 Start button The start button activates the treatment. Trigger inputs These output ports must be used for the trigger probe (in combination with the neutral probe in the blue jack of SET 1). Reset switch This button makes the mathematic processor reset. Power switch Off: the equipment and the display (LCD) are turned off On: the equipment is turned on, the display (LCD) describes transmission protocols. The button must be pressed only when required by the system. _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 6- m e d i l a b __________________________________________________________________ Back of the console 25pin D-sub, communication port jacks for speaker and audio output 3x 4-pin DIN-plugs (not in use at present) 2x 25pin D-subs (not connected) Plug (male) of communication cable fuse carrier product information and serial number LEDcontrol for charge state of battery jack for battery charger Connector plug for charging device Plug (male) of communication cable: This cable connects the algonix console to the computer. Connector plug for charging device: When no treatments are carried out the charging device supplies the battery of the algonix console with a charge current. LED-control for charge state of battery “ON”: As soon as the connected charging device is supplied with supply voltage, the control lamp signals “ON”. LED-control for charge state of battery “HI”: The lamp “HI” provides information about the saturation state of the battery. The more charged the battery is the lesser the efficacy of the lamp “HI” will be. When the lamp “HI” goes off during charging, charge the battery for another hour. Afterwards the battery will be fully charged. _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 7- m e d i l a b __________________________________________________________________ Preparing the patient for the treatment 1. Inform your patient about the contraindications for the algonix by medilab treatment and make sure none of the contraindications apply to him or her. Otherwise DO NOT treat the patient! 2. Ask the patient to drink two litres of fluid (mineral water, isotonic drinks and herbal teas) before, during and after their treatment course. Give him or her a glass of water to drink. 3. Ask the patient to remove all jewellery and metal before the treatment. 4. Ask your client to undress the body part to be treated. 5. Ask your patient to provoke the pain and to indicate the point which hurts the most. 6. Clean the patients´ skin on the area to be treated with a wet, warm towel and dry the skin. This removes body creams, oils and natural skin secretions that may hinder the effectiveness of the treatment. If you are going to perform a treatment in the face region, make sure the face is cleansed of all make-up and face creams. If necessary, remove hair from the area to be treated. 7. Apply electrolyte CEL 144 on the complete area to be treated. This decreases the interface impedance between the probes and the skin and skin irritations can be avoided. Applying the right electrolyte is crucial since one of the most important aspects for algonix by medilab treatments to be successful is creating a good interface between the probes and the patients skin. _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 8- m e d i l a b __________________________________________________________________ Preparing the algonix by medilab system for treatment 1. Switch off the battery recharger. 2. Plug all necessary probes in the corresponding jacks on the console. 3. Switch on the computer and the monitor. Windows will start automatically. 4. The software has been pre-installed by the supplier. Click twice on the desktop icon for the algonix by medilab software: algonix icon 5. You will see a presentation about algonix by medilab. To end the presentation and start the treatment click on any area of the screen. _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 9- m e d i l a b __________________________________________________________________ 6. Click on Interrelation Treatment Focus to start the program. 7. Enter the system password (default 00000) and click on Verify. _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 10- m e d i l a b __________________________________________________________________ 8. Click on Auto-Setup-Mode. 9. You are asked to turn on the console by pressing the red power switch on the front panel. Do so. After you have pressed the red switch you have to wait for approximately 6 seconds before clicking the Ready button on the screen. This is very important. The system will only be working fine, if you wait for approximately 6 seconds. During this time you will hear two beeps. _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 11- m e d i l a b __________________________________________________________________ 10. Click on Negotiate Link, then click on Enter. _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 12- m e d i l a b __________________________________________________________________ 11. Click on Interactive Autonomic Regulatory Therapy. 12. The General Menu will appear. It shows a human body from the front and from the back. _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 13- m e d i l a b __________________________________________________________________ Treatment 1. Click on the body part you wish to treat in the General Menu. In order to reach a good result, it is important to find the correct body part to be treated. 2. The user interface for the treatment opens. _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 14- m e d i l a b __________________________________________________________________ 3. You have to set the following parameters: Clinical Index Status 1. Click on Clinical Index Status and choose the program you wish to use by selecting it from the drop down menu on the bottom. In the menu you will find all conditions which can be treated with algonix by medilab. In order to reach good results choosing the right program is very important.1 2. Wait until you hear a beep. Then click Apply. If you want to leave the Clinical Index Status window without making a selection, click on Cancel. Select – Audio Volume Choose the desired loudspeaker volume from the drop down menu. It is suggested to keep a low volume. Dynamic Range algonix by medilab allows you to change the digital filter band width. Open the drop down menu and choose Broad Bandwith. This way the whole tissue can be read. Intensity Level You can choose the intensity of treatment current from the drop down menu. It is better to forego the selection, though. This way the machine can autonomously supply the current intensity suited best. Should the patient feel uncomfortable limit the intensity by choosing the desired level. 1For a list of all programs available see: Appendix A – List of Programs in the “Clinical Index Status” _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 15- m e d i l a b __________________________________________________________________ 4. After having fixed all parameters click the Sngl Mode button. 5. After having prepared your patient as described on page 8 position the probes on the tissue. Position the neutral probe on the point that the patient indicated hurts most. Position the active probe several centimetres apart. 6. Press the start button on the probe or on the front of the console to start the treatment. 7. After about 20 seconds the stimulation stops and the treatment results are displayed on the screen. 8. Follow all algonix by medilab suggestions: The artificial intelligence system will guide you through the treatment. _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 16- m e d i l a b __________________________________________________________________ The user interface during the treatment: Area 1 Area 2 Area 3 Area 1: Operational Method Instructions: This dialogue box gives information concerning the results of the previous stimulation and makes suggestions how to continue the treatment. Area 2: Real Time Treatment Response Level Monitor: This graphic shows the calculation algorithm. A near and superimposed graphic means that algonix by medilab is doing frequency scanning to thoroughly read the tissue´s bio-impedance vector to find information about pathological conditions. Changing graphics mean that algonix by medilab is solving integral-differential equations in real time. This gives the device an idea of the concentration of extra-cellular and intra-cellular liquids, the values of potential difference and the cellular membrane capacity. Flat and far away graphics mean that algonix by medilab has no more data to analyse. Area 3: Evaluation Of Bio-electrical Potential: This graphic shows the transfer efficiency of the energy between the two probes in real time. _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 17- m e d i l a b __________________________________________________________________ Using the markers You can choose up to 7 markers to mark the points you wish to treat. 1. Click on Setup-Auto to open the regulation markers’ window. 2. Click on Marker On and select one of the six options under Specific Treatment Targets on the left. 3. Do not change the Interface-Accessories area, unless you use a cylindrical probe and plaques. In this case select Specific Electrode Set In Use. 4. Click on Apply to get back to the treatment screen with the 7 lined up markers on the right bottom of the picture. 5. Click on the central marker (O) first. Use the mouse to position it on the picture, on the point which hurts the most. If you want to change its position, click on a different point on the body and the marker will position itself on the new point. 6. Proceed in the same manner with the other markers. Position them on the most significant points of the area you are going to treat. You can use up to 7 markers. 7. Activate all markers with a double click on each positioned marker. Activated markers will blink quickly. 8. Click on Auto Mode. Now the system is ready. 9. Start the treatment by pushing the button on the probe or the red Start button on the console. 10. Position the active probe on the blinking point. Position the neutral probe about 10-15 centimetres apart and, in any case, outside of the treatment area. 11. Start the treatment. When the first stimulation is finished, the next marker will blink. Position the active probe on that point and continue the treatment. Proceed this way until all markers are off and lined up. _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 18- m e d i l a b __________________________________________________________________ Shutting down the algonix by medilab system after treatment 1. Click on Main Menu in the top menu 2. Click the cross at the extreme top right of the screen to shut down the program. 3. Click OK. 4. Press the red power switch on the front of the algonix by medilab console. 5. Switch on the battery charger. 6. Shut down Windows. _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 19- m e d i l a b __________________________________________________________________ Probes and electrolyte Probes In order to stimulate and/or measure tissue you have to create an interface between the tissue and the equipment. In the case of algonix by medilab this interface is created with special metallic probes. 1 Mini plates 4 Indifferent probe (small & large tips) 2 Hand bars 5 Large double roller 3 Trigger probe general purpose (small & large tips) 6 Large footplate set _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 20- m e d i l a b __________________________________________________________________ Differentiation of probes 1. Differentiation according to the amount of poles: • unipolar probe When using this type of probe, the circuit is completed through a backplate probe (hand bar). The current runs from the unipolar probe through the patient to the backplate probe. Probes of this category: Trigger probe general purpose, indifferent probe • bipolar probe When using this type of probe the circuit is completed through two poles, integrated in one probe. The current runs from pole 1 of the bipolar probe through the patient to pole 2. Probe of this category: Large double roller 2. Differentiation according to connection: • Pin plug socket Probes with this type of connection are attached via red/blue cable and spiral cable respectively. Probes of this category: Indifferent probe, large double roller • Mini-DIN plug Probes with this type of connection are attached via black DIN cables with microphone plug. Probe of this category: Trigger probe general purpose _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 21- m e d i l a b __________________________________________________________________ Electrolyte Using the electrolyte CEL 144 is crucial to obtain the electro-chemical processes needed for the treatment with algonix by medilab. It was especially designed to provide the ideal interface between probe and tissue. Due to horny layers and dead skin cells the interface between probe and tissue has a very low conductivity. Applying the electrolyte CEL 144 allows the current to bypass horny layer, avoid polarization and increase conductivity. The electrolyte CEL 144 was compared to other similar products on the market. These are the results: 7000 6000 beautytek Electrolyte* Ohm/cm 5000 Pharmaceutical Innovations Lectron II 4000 Parker Spectra 360 3000 Parker Tensive Gel 2000 Tap Water 1000 0 10 Hz 10 kHz Test Frequency (Hz) Specific resistance 120 100 Millisiemens/cm beautytek Electrolyte 80 Pharmaceutical Innovations Lectron II Parker Spectra 360 60 Parker Tensive Gel 40 Tap Water 20 0 10 Hz 100 Hz 1 kHz 10 kHz 100 kHz Frequency (Hz) Specific conductivity The tests demonstrated that CEL 144 has a lower specific resistance compared to other products and a much higher specific conductivity. Another very important point is the ionic composition of the electrolyte. _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 22- m e d i l a b __________________________________________________________________ The electrolyte for algonix by medilab is multifunctional. It a) keeps the probe potential stable b) avoids “noise” under probes c) provides optimum coupling with equipment input impedance d) removes condenser effect from the probes The electrolyte CEL 144 consists of the following components (in diminishing quantity order, according to INCI-EU): AQUA CETEARYL ALCOHOL CITRUS AURANTIUM AMYLASE PHOSPHOLOPIDIS, ETHYL LINOLEATE PEG 10 SODIUM CHLORIDE, POTASSIUM SORBATE SODIUM CARBOMER ASCORBIC ACID DAUCUS CAROTA & PROPYLENE GLYCOL METHYLPARABEN POTASSIUM CLHLORIDE SOLUM FULLONUM GINGKO BILOBA PRUNUS DULCIS Why CEL 144 is obligatory The algonix by medilab system will only work correctly with the electrolyte CEL 144. Using different electrolyte gels can increase or decrease the average width of responding signals and create a non-desired potential difference. This can cause distorted waves destroying all or part of the treatment benefits. A different gel or diluted electrolyte can lead to a non-linear transfer signal, introducing new resistance and reactions. When reading data, algonix by medilab will encounter different impedances, not linked to pathology, but to particular physiological gel characteristics. This will result in harmful therapy results. _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 23- m e d i l a b __________________________________________________________________ Appendix A – List of Programs in the “Clinical Index Status” _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 24- m e d i l a b __________________________________________________________________ Appendix B – Guidelines for algonix treatments This guideline is not written to make remote diagnoses, suggest therapies or give recommendations. Rather, it explains some general procedures, which came from our experience and which are supposed to give a better understanding of the treatment plan with algonix. 1. 2. 3. 4. At the beginning of the treatment, locate and quantify the pain or discomfort. That means: You may have to ask the patient to provoke the pain, for example by movement or touch. Then ask the patient to indicate the point which hurts the most (maximum pain point). Tell your patient to quantify the pain before and after the treatment on a scale of 1 to 10 (for example by using the algonix pain questionnaire). Apply electrolyte CEL 144 to the complete area which is to be treated. Afterwards carry out slow motions with both of the 5 ¼ tip probes or the double roller. In doing so, you must never loose skin contact. Apply as much pressure with the probes as is tolerable for the patient. Next to the selection of the program the selection of the intensity is the most important thing. Always start the treatment with maximum intensity. The patient should at most feel a slight prickle, under no circumstances must the treatment be unpleasant. Otherwise you have to reconsider and readjust the scheme of the program, the program, the intensity or the localization. Position the indifferent probe (blue cable) on the maximum pain point or on the pathological tissue identified by diagnosis. Position the active probe (black cable) on a point a few centimetres apart from the maximum pain point and repeat this procedure with several points around the pain area. In doing so you must never loose skin contact. As the case may be, the following programs can be used singly or in combination (one after the other). For pain of solely muscular origin please select one of the programs listed below or a combination of several of them. Treatment Objective -> General - Specific Event Range III For general treatment and treatment of acupuncture points Treatment Objective -> Spasmolysis–Smooth Muscle Of The Arterial And Venous Blood Vessels For better blood circulation In the case of neuronal problems, such as numbness or paresthesia, you may additionally select the program Treatment Objective -> General - Specific Event Range III as well as the program Treatment Objective -> Restoration Of Polarization Of The Nerves (Sweep -18y). algonix cannot remedy dystopias of bones or abnormalisms. But the aftereffects, such as irritations of muscles and nerves, can be treated. Often, ligaments are affected as well. In these cases select: Treatment Objective -> Tonification Of The Elastic Fibers (Sweep 33) Specific Treatment Focus On Musculoskeletal Problems G1-> (Sweep ~11y) _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 25- m e d i l a b __________________________________________________________________ If old age or a former accident can be the cause for pain, select: Treatment Objective -> Reduction Of Incipient Degeneration Process (Sweep 31) Treatment Objective -> General – Specific Event Range Q-2 In most cases an inflammation can be an additional cause for pain, although signs for an inflammation may be missing. In this case the experience of a physician will be helpful. If you suspect an inflammation, you could select the following program: Treatment Objective -> Reduction Of The Inflammatory Process (Sweep 21) For traumas, you may select the following program: Specific Treatment For Injuries To The Joints Contusion & Distortion (Sweep 32) The program Treatment Objective -> Circular Spinner Method may – among other problems – be used for dysregulations of the autonomous nervous system (Treatment Objective -> Circular Spinner Method -B- Medium) Treatment Objective -> General – Specific Event Range Q-1 Either for muscular traumas or for myalgias caused by reflexive spasms. Treatment Objective -> General – Specific Event Range Q-2 Can be applied best in cases of pain due to immobility or in rest periods after mobility or at night. Especially, if the patient also reports muscular fatigue and cramps. It must be stressed, that the success of the treatment depends on the right combination of program, intensity and localization. The treatment with algonix will certainly be the more efficient, the more precise the diagnosis is. However, should the origin of the pain be unknown, you can find the right therapy in collaboration with the patient – as described above – by trying different programs. In the process you have to ask the patient as to when he feels a pleasant and tolerable sensation. As soon as the treatment starts to become unpleasant for the patient the intensity must be reduced until the patient only feels a slight sensation again. If this is not possible, you need to change the program. In rare cases certain points may be reacting over-sensitive. Move to a non-sensitive spot in the proximity then. Below you will find several diagnoses and possible treatment programs, which developed from our daily experience. Please bear in mind that these are only examples. As described above, the suitable program should be selected with the collaboration of therapist, patient and algonix. Headache (cervicocephal) Treatment Objective -> General – Specific Event Range III Specific Treatment Focus On Musculoskeletal Problems G1 -> (Sweep ~11y) Should the neck muscles be tense, employ also Treatment Objective -> General – Specific Event Range Q-1 Depending on the diagnosis, further programs for headaches can be selected from the program list. _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 26- m e d i l a b __________________________________________________________________ Painful scars Treatment Objective -> General – Specific Event Range III Treatment Objective -> Tonification Of The Elastic Fibers (Sweep 33) Specific Treatment Focus On Musculoskeletal Problems G1 -> (Sweep ~11y) Treatment Objective -> General – Specific Event Range Q-1 Nerve blockages Treatment Objective -> Restoration Of Polarization Of The Nerves (Sweep -18y) Treatment Objective -> General – Specific Event Range III Treatment Objective -> Reduction Of The Inflammatory Process (Sweep 21) Tendosynovitis (Tendonitis) Treatment Objective -> Tonification Of The Elastic Fibers (Sweep 33) For tendosynovitis (tendonitis) due to sports, employ in addition: Treatment Objective -> Reduction Of The Inflammatory Process (Sweep 21) Specific Treatment Focus On Sprains and Strains: Grade I ->(Sweep 101E) Arthritis Treatment Objective -> Reduction Of The Inflammatory Process (Sweep 21) Specific Treatment Focus On Musculoskeletal Problems G1 -> (Sweep ~11y) Specific Focus On Affliction Of Joints Result Of Arthralgia Uratic Diathesis (Sweep 41) Polyneuropathy Treatment Objective -> Restoration Of Polarization Of The Nerves (Sweep -18y) Treatment Objective -> General – Specific Event Range III Frozen shoulder Treatment Objective -> Reduction Of The Inflammatory Process (Sweep 21) Specific Treatment Focus On Musculoskeletal Problems G1 -> (Sweep ~11y) Treatment Objective -> Reduction Of Incipient Degeneration Process (Sweep 31) Treatment Objective -> General – Specific Event Range III Periarthritis with rotator cuff calcification Specific Treatment Focus On Musculoskeletal Problems G1 -> (Sweep ~11y) Specific Focus For Muscles Surrounding Joints And Rheumatoid Complains (Sweep 48) (Periarticular muscles and rheumatic disorders) Treatment Objective -> Reduction Of The Inflammatory Process (Sweep 21) _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 27- m e d i l a b __________________________________________________________________ Epicondylitis humeroradialis (tennis elbow) Epicondylitis humeroulnaris (golf elbow) Treatment Objective -> General – Specific Event Range III Treatment Objective -> Reduction Of The Inflammatory Process (Sweep 21) Specific Treatment Focus On Musculoskeletal Problems G1 -> (Sweep ~11y) Treatment Objective -> Tonification Of The Elastic Fibers (Sweep 33) Cervical (neck pain) Treatment Objective -> General – Specific Event Range Q-1 Treatment Objective -> General – Specific Event Range III Specific Treatment Focus On Musculoskeletal Problems G1 -> (Sweep ~11y) Treatment Objective -> Tonification Of The Elastic Fibers (Sweep 33) Treatment Objective -> Reduction Of The Inflammatory Process (Sweep 21) Post partum mastitis Treatment Objective -> Reduction Of The Inflammatory Process (Sweep 21) Treatment Objective -> General – Specific Event Range III Lumbar pain (back pain) Treatment Objective -> General – Specific Event Range Q-1 Treatment Objective -> General – Specific Event Range III Specific Treatment Focus On Musculoskeletal Problems G1 -> (Sweep ~11y) Treatment Objective -> Tonification Of The Elastic Fibers (Sweep 33) Treatment Objective -> Restoration Of Polarization Of The Nerves (Sweep -18y) Herniated disk Treatment Objective -> Restoration Of Polarization Of The Nerves (Sweep -18y) Treatment Objective -> Tonification Of The Elastic Fibers (Sweep 33) Treatment Objective -> Reduction Of The Inflammatory Process (Sweep 21) Sciatica Treatment Objective -> Restoration Of Polarization Of The Nerves (Sweep -18y) Treatment Objective -> Tonification Of The Elastic Fibers (Sweep 33) Specific Treatment Focus On Musculoskeletal Problems G1 -> (Sweep ~11y) Treatment Objective -> Reduction Of The Inflammatory Process (Sweep 21) Treatment Objective -> General – Specific Event Range Q-1 _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 28- m e d i l a b __________________________________________________________________ Coxalgia without dysfunction Specific Treatment Focus On Musculoskeletal Problems G1 -> (Sweep ~11y) Treatment Objective -> General – Specific Event Range III Treatment Objective -> Reduction Of Incipient Degeneration Process (Sweep 31) Treatment Objective -> General – Specific Event Range Q-1 Coxarthrosis Treatment Objective -> General – Specific Event Range III Specific Treatment Focus On Musculoskeletal Problems G1 -> (Sweep ~11y) Treatment Objective -> Reduction Of Incipient Degeneration Process (Sweep 31) Treatment Objective -> Reduction Of The Inflammatory Process (Sweep 21) Knee pain after injury Specific Treatment Focus On Sprains and Strains: ankles, knee, wrist Specific Treatment Objective For Hematoma Lymphoedema Trauma Surgery – Roller Only Treatment Objective -> Reduction Of The Inflammatory Process (Sweep 21) Specific Treatment For Injuries To The Joints Contusion & Distortion (Sweep 32) Specific Treatment Focus On Musculoskeletal Problems G1 -> (Sweep ~11y) Gonarthrosis Treatment Objective -> General – Specific Event Range III, Bachmann-knee-points, Gb 34, Ma 36, Bl 40, Ni 10 Specific Treatment Focus On Musculoskeletal Problems G1 -> (Sweep ~11y) Treatment Objective -> Reduction Of Incipient Degeneration Process (Sweep 31) Treatment Objective -> Reduction Of The Inflammatory Process (Sweep 21), z.B. for secundary activated osteoarthrosis Achilles tendonitis Treatment Objective -> Reduction Of The Inflammatory Process (Sweep 21) Treatment Objective -> Reduction Of Incipient Degeneration Process (Sweep 31) Treatment Objective -> Tonification Of The Elastic Fibers (Sweep 33) Specific Treatment Focus On Musculoskeletal Problems G1 -> (Sweep ~11y) Acute traumas and after surgery Specific Treatment Objective For Hematoma Lymphoedema Trauma Surgery – Roller Only Treatment Objective -> General – Specific Event Range Q-1 Specific Treatment Focus On Sprains and Strains (ankles, knee, wrist): Grade I -> (Sweep 101E) (slight): in case of minimally or partially pulled tendons with normal stability and functionality of the joint. _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 29- m e d i l a b __________________________________________________________________ Grade II -> (Sweep 102E) (medium): in case of partial tendon tears, slightly loose joints and minor dysfunction. Grade III -> (Sweep 103E) (severe): in case of torn ligaments or tendons, which are completely detached from the bone. The joint is very loose and not functioning. Treatment Objective -> Spasmolysis-Smooth Muscle Of The Arterial And Venous Blood Vessels Treatment Objective -> Reduction Of Incipient Degeneration Process (Sweep 31) And then: Treatment Objective -> Tonification Of The Elastic Fibers (Sweep 33) Treatment Objective -> Restoration Of Polarization Of The Nerves (Sweep -18y) Treatment Objective -> Circular Spinner Method (depending on reaction and tolerability -A- Long, -B- Medium or -C- Short) _____________________________________________________________________________________________________ medilab research + trading GmbH&Co., Wuerzburg - 30-