Colposcopes from Carl Zeiss Enabling enhanced diagnostics
Transcription
Colposcopes from Carl Zeiss Enabling enhanced diagnostics
Colposcopes from Carl Zeiss Enabling enhanced diagnostics 2 Early detection with ZEISS Colposcopes Even more reliability for your patients Kolposkop 150 FC Kolposkop E Kolposkop 150 FC with optionally integrated 1 CCD video camera Why should you choose a colposcope from Carl Zeiss? Optical brilliance Different magnification settings Selectable working distance facilitates the assessment of anomalies offer a general overview at a low power with objective lenses featuring different in the epithelium and therefore also and clear recognition of detail at high focal lengths. enables differential diagnosis. powers. Outstanding illumination Straight, inclined or tiltable tube patient education allows you to clearly recognize color enables ergonomically correct viewing with an optionally available video camera differences in the epithelium and conditions. or an adapter for a digital camera. Large focusing, inclination Attachment to examination chair and tilt ranges, or floor stand in addition to the variable height for stationary or mobile use. Ideal documentation for visualize tissue patterns with excellent clarity. Swing-in red-free filter enhances the contrast of the colposcope adjustment of the suspension arm image. and an ergonomically correct handgrip, allow fast and reliable positioning of the colposcope. 3 Kolposkop 150 FC Optical brilliance The versatile Kolposkop 150 FC meets the critical demands made on a top-class colposcope: •High-intensity fiber optic illumination, via integrated light guide •Convenient, single-hand operation using the ergonomically arranged controls •Large fine focusing range •5-step magnification changer •W ide field optics for the a large field of view You can choose the system combination best suited for your requirements: •Attachable to suspension mount/ examination chair or floor stand •Straight or inclined binocular tube for convenience and comfort •Optionally integrated MediLive® Primo 1CCD video camera for clear documentation of findings and patient education Performance features of Kolposkop 150 FC model Kolposkop KSK 150 FC 4 Illumination 12 V/100 W cold light, fiber optic illumination, adjustable Working distance 250 mm, 300 mm Magnification 3.5x - 21.5x (at working distance 250 mm, 12.5x eyepieces) Fine focusing 18 mm Viewing tube Straight, inclined, 180° tiltable binocular tube Red-free filter Swing-in Suspension system Suspension mount (connecting tube for examination chair), rollable floor stand Lifting range +/- 230 mm Video camera Optionally integrated, 1CCD, Y/C (S-Video), VBS (Composite), PAL or NTSC Kolposkop E Details that count Kolposkop E offers outstanding features for use in routine colposcopy: •Attractive price •Ease of use and flexibility •High optical quality Various configurations allow the Kolposkop E to be tailored to the requirements of your office: •Attachable to suspension mount/ examination chair or floor stand •Straight or inclined binocular tubes •F ixed magnification or with 3-step magnification changer •MediLive Primo 1CCD video camera (option) for documentation of findings and patient education Performance features of Kolposkop E Illumination 6 V/15 W halogen illumination Working distance 300 mm Magnification 5x or 3x/5x/8x with 3-step changer Viewing tube Straight or inclined binocular tube Red-free filter Swing-in Suspension system Suspension mount (connecting tube for examination chair), rollable floor stand Lifting range Suspension mount +/- 260 mm Video camera 1CCD, Y/C (S-Video), VBS (Composite), PAL or NTSC 5 Kolposkop OPMI pico (SAD) For routine and more intricate procedures Kolposkop OPMI® pico (SAD) is a compact, high-performance, easy-to-use microscope. •High-intensity fiber optic illumination •Ergonomic arrangement of all controls •Objective lens with fine focusing •5-step magnification changer •W idefield optics •Very mobile floor stand with four easy-to-move, lockable casters •Suitable as SAD (Sexual Assault Documentation) Kolposkop OPMI pico (SAD) is available in various configurations: •Straight or inclined binocular tube for excellent ergonomics •Optionally integrated MediLive 1CCD video camera for clear documentation of findings and patient education •Optionally integrated Full HD (1080p) or HD (720p) video camera effectively aids co-observation, assistance and procedural documentation. Performance features of Kolposkop OPMI pico (SAD) 6 Illumination 12 V/100 W cold light, fiber optic illumination, adjustable Working distance 250 mm, 300 mm Magnification 3.5x - 21.5x (at working distance 250 mm, 12.5x eyepieces) Fine focusing 12 mm via focusing objective lens Viewing tube Straight or inclined Red-free filter Swing-in Suspension system Rollable floor stand Lifting range +/- 300 mm Video camera ptionally integrated 1CCD video camera, Y/C (S-Video), VBS (Composite), PAL or NTSC. O Optionally integrated Full HD (1080p) or HD (780p) video camera, Y/C (S-Video), VBS (Composite), PAL or NTSC Seeing and identifying Reliable diagnosis Both skill and high-quality optics are needed to recognize precancerous changes. Carl Zeiss has been developing and producing world-class optical systems for over 160 years. We at Carl Zeiss make the world visible when the naked eye is not enough. That is our vision. Central polypoid ectopia Colposcopy: Rough leukoplakia of the anterior lip, vulnerable, vascular transformation zone on the posterior lip Abnormal portio with mosaic and punctuation After the application of acetic acid: aceto-white, hollow-like mosaic on the anterior lip; vulnerable, vascular transformation zone on the posterior lip Cytology: Signs of keratinization with dyskeratosis Histology: CIN III of all layers. Suspected CIN III, Pap IVA Application photos: Dr. Peter Schomann, Lüneburg, Germany 7 Powerful accessories For crisp visualization and effective documentation of your work Ideal video documentation Visualization and Documentation Chair attachment The optionally integrated video camera MEDIALINK™ 100 ensures simple and Using an appropriate mount, the allows you to efficiently document efficient image data management: it Kolposkop E and the Kolposkop 150 FC important findings. The live image on connects several video sources with the can be attached to examination chairs the monitor enables patient education. preferred USB storage media. At the push from different manufacturers. Mounts of a button, your treatment images and for attaching connecting tubes to Digital photography videos are transferred to the patient examination chairs are available from As an alternative to video documenta- record for viewing, editing or document- the respective chair manufacturer. tion, d igital photography is also ideal for ing. Network capability also enables the fast documentation of findings. access to patient records from any Laser attachment location in the practice – for a fast and An external micromanipulator can be efficient workflow. directly attached to the Kolposkop 150 FC to perform CO2 laser therapies. Video documentation 8 Digital photography: FlexioStillTM & FlexioMotionTM MEDIALINKTM 100 Laser attachment Condition directly after laser therapy, anterior lip 9 10 Light microscopes from Carl Zeiss Make the examination complete The early diagnosis of abnormalities of the Cervix uteri are ideally rounded off by cytological findings. The native smear is also an integral part of the patient examination: it allows fast diagnosis and hence facilitates therapy of inflammatory processes. Light microscopes from Carl Zeiss offer outstanding benefits for use in gynecology: •Brilliant optics •Ease of use and flexibility •Upgradeable for advanced fluorescence techniques 11 Argentina Carl Zeiss Argentina S.A. Calle Nahuel Huapi 4015 / 25 C1430 BCO Buenos Aires Argentina Phone: +54 11 45 45 66 61 [email protected] Australia Carl Zeiss Pty Ltd Tenancy Office 4, Level 1 40-52 Talavera Road North Ryde NSW 2113 Australia Phone: +61 2 9020 1333 [email protected] Austria Carl Zeiss GmbH Laxenburger Str. 2 1100 Vienna Austria Phone: +43 1 79 51 80 [email protected] Belgium Carl Zeiss NV-SA Ikaroslaan 49 1930 Zaventem Belgium Phone: + 32 2 719 39 11 [email protected] Brazil Carl Zeiss do Brasil Ltda. Av. Naçoes Unidas, 21711 CEP04795-100 São Paulo Brazil Phone: +55 11 5693 5521 [email protected] Canada Carl Zeiss Canada Ltd. 45 Valleybrook Drive Toronto, ON M3B 2S6 Canada Phone: +1 800 387 8037 [email protected] China Carl Zeiss Shanghai Co. Ltd. 1/f., Ke Yuan Building 11 Ri Yin Nan Road Waigaoqiao Free Trade Zone 2005 Yang Gao Bei Road Shanghai 200131 China Phone: +86 21 5048 17 17 [email protected] Carl Zeiss Meditec AG Goeschwitzer Strasse 51–52 07745 Jena Germany www.meditec.zeiss.com/colposcopy www.meditec.zeiss.com/contacts Czech Republic Carl Zeiss spol. s.r.o. Radlická 14/3201 150 00 Prague 5 Czech Republic Phone: +420 233 101 221 [email protected] France Carl Zeiss Meditec France SAS 60, route de Sartrouville 78230 Le Pecq France Phone: +33 1 34 80 21 00 [email protected] Germany Carl Zeiss Meditec VG mbH Carl-Zeiss-Strasse 22 73447 Oberkochen Germany Phone: +49 7364 20 6000 [email protected] Surgical Ophthalmology: Phone: +49 800 470 50 30 [email protected] Hong Kong Carl Zeiss Far East Co. Ltd. Units 11-12. 25/F Tower 2, Ever Gain Plaza No. 88 Container Port Road Kwai Chung Hong Kong Phone: +852 2332 0402 [email protected] India Carl Zeiss India Pvt. Ltd. 22. Kensington Road Ulsoor Bangalore 560 008 India Phone: +91 80 2557 88 88 [email protected] Italy Carl Zeiss S.p.A. Viale delle Industrie 20 20020 Arese (Milan) Italy Phone: +39 02 93773 1 [email protected] Japan Carl Zeiss Meditec Japan Co. Ltd. Shinjuku Ku Tokyo 160-0003 22 Honchio-Cho Japan Ophthalmic instruments: Phone: +81 3 33 55 0331 [email protected] Surgical instruments: Phone: +81 3 33 55 0341 [email protected] Malaysia Carl Zeiss Sdn Bhd. Lot2, Jalan 243/51 A 46100 Petaling Jaya Selangor Darul Ehsan Malaysia Phone: +60 3 7877 50 58 [email protected] Mexico Carl Zeiss de México S.A. de C.V. Avenida Miguel Angel de Quevedo 496 04010 Mexico City Mexico Phone: +52 55 59 99 0200 [email protected] Netherlands Carl Zeiss B.V. Trapezium 300 Postbus 310 3364 DL Sliedrecht Netherlands Phone: +31 184 43 34 00 [email protected] New Zealand Carl Zeiss (N.Z.) Ltd. 15B Paramount Drive P.O. Box 121 - 1001 Henderson, Auckland 0650 New Zealand Phone: +64 9 838 5626 [email protected] Poland Carl Zeiss sp. Z o.o. ul. Lopuszanska 32 02-220 Warsaw Poland Phone: +48 22 858 2343 [email protected] Singapore Carl Zeiss Ptd. Ltd. 50 Kaki Bukit Place Singapore 415926 Singapore Phone: +65 6741 9600 [email protected] South Africa Carl Zeiss (Pty.) Ltd. 363 Oak Avenue Ferndale Randburg 2194 South Africa Phone: +27 11 886 9510 [email protected] South Korea Carl Zeiss Co. Ltd. Seoul 121-828 Mapo-gu 141-1, Sangsu-dong 2F, BR Elitel Bldg. South Korea Phone: +82 2 3140 2600 [email protected] Spain Carl Zeiss Meditec Iberia S.A.U. Ronda de Poniente, 15 Tres Cantos 28760 Madrid Spain Phone: +34 91 203 37 00 [email protected] Sweden Carl Zeiss AB Tegeluddsvaegen 76 10254 Stockholm Sweden Phone: +46 84 59 25 00 [email protected] Switzerland Carl Zeiss AG Feldbachstrasse 81 8714 Feldbach Switzerland Phone: +41 55 254 7534 [email protected] Thailand Carl Zeiss Thailand Floor 8, Thosapol Land Building 2 230 Ratchadapisek Road Huaykwang, Bangkok 10310 Thailand Phone: +66 2 2 74 06 43 [email protected] United Kingdom Carl Zeiss Ltd. 15-20 Woodfield Road Welwyn Garden City Hertfordshire, AL7 1JQ United Kingdom Phone: +44 1707 871200 [email protected] United States of America Carl Zeiss Meditec, Inc. 5160 Hacienda Drive Dublin, CA 94568 USA Phone: +1 925 557 4100 [email protected] EN_30_010_0139I Printed in Germany AW-CZ-IV/2012 Uoo OPMI, Medialink, FlexioStill, FlexioMotion and MediLive are registered trademarks of Carl Zeiss. Printed on environmentally-friendly paper. Subject to change in design and scope of delivery as a result of ongoing technical development. Your local contact:
Similar documents
Colposcopes from Zeiss
The versatile colposcope meets the critical demands made on a top-class colposcope: • High-intensity fiber optic illumination, via integrated light guide • Convenient, single-hand operation using...
More informationOPMI Vario Expand your vision
Viale delle Industrie 20 20020 Arese (Milan) Italy Phone: +39 02 93773 1 [email protected] Japan Carl Zeiss Meditec Japan Co. Ltd. Shinjuku Ku Tokyo 160-0003 22 Honchio-Cho Japan Ophthalmic inst...
More informationHumphrey Matrix Brochure
Carl Zeiss Shanghai Co. Ltd. 1/f., Ke Yuan Building 11 Ri Yin Nan Road Waigaoqiao Free Trade Zone 2005 Yang Gao Bei Road Shanghai 200131 China Phone: +86 21 5048 17 17 [email protected]