Delta UPS - A
Transcription
Delta UPS - A
Delta UPS The power behind competitiveness About Delta Electronics Group 2 Confidential PPT_UPS_Generic_EN_V6 Our Mission To provide innovative, clean and efficient energy solutions for a better tomorrow Confidential PPT_UPS_Generic_EN_V6 Delta Group Overview Established in 1971; Global HQ in Taipei, Taiwan WW No. 1 in Switching Power Suppliers and DC Brushless Fans Dedicated to developing clean and energy-efficient power solutions • Power Management • Renewable Energy – Wind and Solar Energy System • Thermal & Cooling Fans • Power Train System and Key Components for Electronic Vehicles and Hybrid Electric Vehicles • Networking Solutions • Industrial Automations System Devices • High-end Display and 3D Cinema Systems • Innovative Miniaturized Passive Components • LED Lighting 4 Confidential PPT_UPS_Generic_EN_V6 Delta as a Mission Critical Infrastructure Solutions Provider 5 Confidential PPT_UPS_Generic_EN_V6 Where we stand ….. Specializing in power management and energy-efficient solutions for more than 40 years More than 15 years’ experiences in UPS design and manufacturing Asia Top 5 UPS player Data center alliance partner of WW top data center operators Ensuring mission critical operations by providing reliable and efficient UPS and Data Center infrastructure solutions with excellence performance of TCO (Total Cost of Ownership) Aiming to be a powerful partner to companies that strive to outperform the competition. Member of Green Grid 6 Confidential PPT_UPS_Generic_EN_V6 The power behind competitiveness Delta’s long history of supporting customers from behind-the-scenes. The most competitive companies in the world choose Delta because our products contribute to a customers’ competitiveness significantly. 7 Confidential PPT_UPS_Generic_EN_V6 Delta UPS – 4 Families Agilon, Amplon, Ultron, Modulon Ranging from 0.6kVA to 4000kVA Confidential PPT_UPS_Generic_EN_V6 Delta UPS- Agilon Family Delta UPS - Agilon Family • • • • Agilon ( Agile + On) means agility , small and compact UPS <1kVA, Line-interactive UPS Application: PCs, Peripherals Target Users: Family, SOHO Model: • Confidential VX 600VA 9 PPT_UPS_Generic_EN_V6 Delta UPS - Amplon Family The Delta - Amplon Family • • • • Amplon (Ample + on) means ample and sufficient; medium and stable UPS 1 ~ 12kVA, Single Phase Online UPS Applications: Network devices, Security monitoring and POS Target user: Small & Medium Enterprise, IT, Banking and Government Products • • • • • • Confidential E Series 1-3 kVA N Series 1-3 kVA R Series 1-3 kVA GAIA Series 1-3 kVA N Series 6-12 kVA RT Series 5-10 kVA 10 PPT_UPS_Generic_EN_V6 Delta UPS - Ultron Family Delta UPS - Ultron Family • Ultron (Ultra + on) means state of art, ultimate performance and heavy duty; Delta’s flagship UPS • 10 ~ 4000kVA, Three phase Online UPS • Applications: Large capacity required, Mission-critical Facilities • Target user: Industrial, Manufacturing, Railway, Telecommunication and Medical Products • • • • Confidential EH Series 3:1 10-20 kVA (on-line) HPH Series 3:3 20-40 kVA (on-line) NT Series 20-500 kVA (on-line) DPS Series 60-200 kVA (on-line) 11 PPT_UPS_Generic_EN_V6 Delta UPS - Modulon Family Delta UPS - Modulon Family •Modulon (Modular + on) means modular design. Delta’s modular UPSs provide benefits of scalable planning and purchase-ondemand based on customers’ needs •20 ~ 480 kVA, Three phase Modular Online UPS •Applications: Medium and heavy-duty network farm, Data storage and Financial settlement centers. •Target users: Data center Products •NH Plus Series 20-120 kVA (3-phase, on-line) •DPH Series 25-200 kW (3-phase, on-line) Confidential 12 PPT_UPS_Generic_EN_V6 Delta UPS - Amplon Family Single Phase Online UPS Up to 12 kVA N Series E Series 1 - 3 kVA 1 - 3 kVA R Series GAIA Series N Series 1 - 3 kVA 1 - 3 kVA 6 - 12 kVA RT Series 5 - 10 kVA 13 Confidential PPT_UPS_Generic_EN_V6 N Series 1-3 kVA Wide input voltage range reduces battery discharge probability prolongs battery lifetime. Compact size, savings in the installation space. SMART slot/ MINI slot for mission critical applications. RS232 connectivity with Vista compatible power management software. Applications Long backup model available. – – – – Optional external battery pack. PC, Workstation POS ATM Security 14 Confidential PPT_UPS_Generic_EN_V6 N Series 1-3 kVA Specifications Model Power Rating N-1K N-2K N-3K 1kVA/700W 2kVA/1400W 3kVA/2100W Voltage 220/230Vac, single phase Input Voltage Range 80 ~ 280 Vac. Lower range 80 ~ 176 Vac is acceptable under 50 ~ 100% loading condition. Input Connection Output Receptacle Internal Battery Power cord IEC320 C13 x 4 IEC320 C13 x 8 12V/7Ah x 3 12V/7Ah x 6 ≧14 minutes (half load) ≧ 5 minutes (full load) Backup Time External Battery Pack Rating Interface 12V/7Ah x 6 12V/9Ah x 6 RS232 x 1, MINI slot x 1 RS232x1, SMART slot x 1 Data Line Surge Protector Optional (RJ11/RJ45, phone and network) External Battery Pack WxDxH (mm) 12V/9Ah x 6 UPS Optional. Connection is by Delta standard battery cable. 140 x 366 x 242 140 x 425 x 373 Battery Pack UPS 140 x 366 x 242 14 30.5 Weight (kg) Battery Pack 19.5 15 Confidential PPT_UPS_Generic_EN_V6 R Series 1-3 kVA Standard 19 inches rack / tower configuration (2U). Wide input voltage range reduces battery discharge probability prolongs battery lifetime. Battery independent function to fulfill backup time by customized battery source. Specially for long backup application. High recharging capability: Inbuilt 4.5-5A and optional 8A for 1kVA & 5A for 2/3kVA with extra charger box. SMART slot for mission critical applications. RS232 connectivity with Vista compatible power management software. Optional external battery pack. Applications – Server Rack – ATM – Security – Long Backup Time 16 Confidential PPT_UPS_Generic_EN_V6 R Series Specifications Model Power Rating R-1K R-2K R-3K 1kVA/700W 2kVA/1400W 3kVA/2100W Voltage Input Voltage Range 220/230/240 Vac , single phase 80 ~ 280 Vac. Lower range 80 ~ 175 Vac is acceptable under 50 ~ 100% loading condition. Input Connection Output Receptacle Power cord IEC320 C13 x 4 IEC320 C13 x 8 ; IEC320 C19 x 1 Battery Source Rating 36 Vdc 72 Vdc Battery Charging Max. 5A Max. 4.5A Optional Charger Board* Max. 8A Max. 5A Internal Battery None! Customer can connect to their own battery source based on correct rating. Interface RS232 x 1, SMART slot x 1 Tower Stand Kit Optional Rack Rail Kit Included Data Line Surge Protector Optional External Battery Pack Optional. Connection is by Delta standard battery cable. WxDxH (mm) Weight (kg) 440 x 455.4 x 88.5 6.7 9.2 • Extra charger board is installed inside UPS. 17 Confidential PPT_UPS_Generic_EN_V6 GAIA Series 1-3 kVA Standard 19 inches rack / tower configuration (2U). High input power factor (pf > 0.97) saves installation cost. Wide input voltage range reduces battery discharge probability prolongs battery lifetime. RS232 and USB connectivity with Vista compatible power management software. Inbuilt data line surge protector for phone / fax / network. Programmable output receptacles for efficient energy usage. SMART slot for mission critical applications. Optional external battery pack. Applications – Server Rack – ATM – Security – Audio/Video 18 Confidential PPT_UPS_Generic_EN_V6 GAIA Series Specifications Model Power Rating GAIA-1K GAIA-2K GAIA-3K 1kVA/800W 2kVA/1600W 3kVA/2100W Voltage 200/208/220/230/240Vac, single phase Input Voltage Range 130~275 Vac (Lower range 130 ~ 160 Vac is acceptable under 70% ~ 100% loading condition) Power factor > 0.97 Output Receptacle Internal Battery Backup Time EBC Rating IEC320 C13 x 3 x2 IEC320 C13 x 3 x 2; IEC320 C19 x 1 12V/8.5Ah x 2 12V/8.5Ah x 4 12V/8.5Ah x 6 > 12 minutes (half load) > 4 minutes (full load) > 13 minutes (half load) > 4 minutes (full load) > 15 minutes (half load) > 5 minutes (full load) 8.5Ah x 2 x 2 8.5Ah x 4 x 2 8.5Ah x 6 x 2 Interface RS232 x 1, USB x 1, SMART slot x 1 Data Line Surge Protector Built-in (RJ11/RJ45, phone and network) Tower Stand Kit Included in package Rack Rail Kit Optional External Battery Pack Optional WxDxH (mm) Weight (kg) Confidential UPS 440 x 335 x 89 440 x 432 x 89 440 x 610 x 89 UPS 13 21 31 Battery Pack 16 29 43 Battery Pack 19 PPT_UPS_Generic_EN_V6 N Series 6-12 kVA Wide input voltage range reduces battery discharge probability prolongs battery lifetime. Inbuilt isolation transformer and dual output voltage. Inbuilt automatic and manual bypass switch. Independent bypass input supports hot standby installation. Inbuilt battery for basic backup power requirement. Remote emergency power off function. Optional external battery pack. Applications – IT Room – Medium Office – Banking 20 Confidential PPT_UPS_Generic_EN_V6 N Series Specifications Model GES602N500135 GES123N500135 Model 6kVA/4.2kW 12kVA/8.4kW Input Nominal Voltage Input Voltage Range 220 Vac, single phase 120~280Vac. Lower range 120~176Vac is acceptable under 70~100% loading condition. Input/Output Connection Hard wire (terminal block) Output Nominal Voltage 120 and 220Vac dual, single phase Internal Battery 12V/7Ah x 20 External Battery Pack Rating Charge Current 12V/8.5Ah x 20 12V/7Ah or 8.5Ah, maximum 60 pcs 0.7A Interface 1.3A RS232 x 1, SMART slot x 1, Dry contact x 1 Maintenance Bypass Switch WxDxH (mm) Weight (kg) Built-in UPS 280 x 581 x 784 Battery Pack 280 x 581 x 784 UPS 133 165 Battery Pack 76.7 21 Confidential PPT_UPS_Generic_EN_V6 RT Series 5-10 kVA Standard 19 inches rack / tower configuration (5/6kVA:2U 10kVA:3U). High output power factor 0.9 1+1 parallel redundancy to increase the reliability and flexibility. High input power factor (pf > 0.99) and low input harmonic distortion (iTHD < 5%). High recharging capability: Inbuilt 4A and optional 4A extra charger. One SMART slot and MINI slot for mission critical applications. Multi-language LCD display and status LED. Optional maintenance bypass box Optional external battery pack and charger box. Applications – IT Room – Security – Banking – Long Backup Time 22 Confidential PPT_UPS_Generic_EN_V6 RT Series Specifications Model Power Rating RT-5K RT-6K RT-10K 5kVA/4.5kW 6kVA/5.4kW 10kVA/9kW Voltage 200/208/220/230/240 Vac , single phase Input Voltage Range 100 ~ 300 Vac Input/Output Connection Hard wire (terminal block) External Battery Pack Rating 12V/5Ah x 16 12V/9Ah or 12V/34W x 20 Battery Charging Max. 4A Optional Charger Board** Max. 4A Internal Battery No built-in battery. Customer can connect to their own battery source based on correct rating. Interface RS232 x 1, SMART slot x 1, MINI slot x 1, Parallel port x 1 Rack Rail Kit Optional (tower stand kit is included) Parallel Redundancy 1+1 Maintenance Bypass Box WxDxH (mm) Optional UPS 440 x 671 x 89 440 x 671 x 89 440 x 623 x 131 Battery Pack 440 x 638 x 89 440 x 638 x 89 440 x 595 x 131 UPS 15 15.5 21.3 Battery pack 36 36 66 Weight (kg) 23 Confidential ** Extra charger board is installed inside UPS. PPT_UPS_Generic_EN_V6 Delta UPS – Ultron Family Three Phase Online UPS Up to 4000 kVA EH Series HPH Series NT Series DPS Series 10 -20 kVA 20 - 40 kVA 20 - 500 kVA 60 - 400 kVA 24 Confidential PPT_UPS_Generic_EN_V6 EH Series 10-20 kVA A true online double-conversion 3phase-1phase UPS Advanced DSP controller for fast computation capability and a simplified control circuit for enhanced stability Dual input design to allow different power supply sources for enhanced availability Built-in manual bypass to ensure continuous power to the load even if the UPS is under maintenance A wide input voltage range to reduce battery discharge probability and prolong battery life ECO mode efficiency up to 96% to reduce operating costs Parallel expansion and N+X redundancy up to 4 units without requiring additional cards or equipment Small footprint to save space 25 Confidential Applications – Networking – Data centers – Telecommunications – Medical – Banking – Retail – Industrial PPT_UPS_Generic_EN_V6 EH Series Specifications Model Power Rating EH-10K EH-15K EH-20K 10kVA /8kW 15kVA /12kW 20 kVA/16kW Voltage 220/380 Vac; 230/400 Vac; 240/415 Vac Input Voltage Range 208~304 Vac ( 50%~100% load) / 305~477 Vac (100% load) Output Voltage 220/230/240 Vac ≤105 %: continuous; 106%~110%: 10 minutes; 111%~125%: 1 minute; 126%~150%: 30 seconds Overload Capability Online Mode: up to 91% ECO Mode: up to 96% Efficiency Charge Current Built-in: 4A Additional charger board (optional): 4A Charge Voltage Float charge 272 +/- 2 Vdc Boost charge 280 Vdc SMART Slot x 1, MINI Slot x 1, Parallel Port x 2, RS232 Port x 1, REPO Port x 1, Charger Detection Port x 1 Interface Maintenance Bypass Switch WxDxH (mm) Weight UPS Built-in 200 x 490 x 490 mm 250 x 610 x 650 mm 26 Kg 45Kg 26 Confidential PPT_UPS_Generic_EN_V6 HPH Series 20-40 kW Fully rated power (kVA=kW) for maximum available power Leading AC-AC efficiency up to 96% saves energy costs Low harmonic pollution (iTHD<3%) & high input power factor (>0.99) reduce upstream investment costs Wide input voltage range allows the UPS to operate in harsh electrical environments and extends battery life DSP based technology enables reduction in the number of electronic components to lower failure rate N+X redundancy up to 4 units increases system availability Built-in manual bypass ensures continuous power to the load even if the UPS is under maintenance Flexible arrangement of battery quantity from 34 to 50 pcs optimizes battery investment 27 Confidential Applications – – – – – – – Data centers Telecom Network Banking Medical Metro Industrial PPT_UPS_Generic_EN_V6 HPH Series Specifications Model Power Rating HPH-20K HPH-20K-BN/B HPH-30K HPH-30K-BN/B HPH-40K HPH-40K-BN/B 20kVA /20kW 30kVA /30kW 40 kVA/40kW Voltage 220/380 Vac; 230/400 Vac; 240/415 Vac Input Voltage Range - 40% ~ 20% (242 ~ 477/140 ~ 276 Vac) * * Output Voltage 220/380 Vac; 230/400 Vac; 240/415 Vac ≦105 %: continuous; 106%~≦125%: 10 minutes; 126%~≦150%: 1 minute; >150%: 1 second Overload Capability Battery Charging (Standard model) 5A Battery Charging (HPH-BN/B*) 5A, 9A (option) Float charge ±272 V ±2Vdc, Boost Charge ±280V ±2Vdc Charge Voltage Typical Backup Time (HPH-BN/B*) (At 70% load with internal battery strings) 9A 15 min 10 min 9.5 min Efficiency Online Mode: up to 96% ECO Mode: up to 99% Interface SMART Slot x 1, MINI Slot x 1, Parallel Port x 2, RS232 Port x 1, REPO Port x 1, Charger Detection Port x 1, Input Dry Contact x 2,Output Dry Contact x 6 Maintenance Bypass Switch *HPH-BN: UPS integrated battery model has no batteries inside HPH-B: UPS integrated battery model has batteries inside Confidential Built-in 28 * *When input voltage is 242 ~ 324/140 ~ 187 Vac, the sustainable loading is from 70% to 100% of the UPS capacity. PPT_UPS_Generic_EN_V6 Ultron DPS Series 60-400 kVA IGBT-based UPS with AC-AC efficiency up to 96% 0.9 output power factor, and supporting leading power factor data center server, networking equipment Able to parallel for N+X redundancy, hot stand-by and support 2(N+1) configuration to meet level tier 4 reliability Wide input voltage range reduces battery discharging Advanced battery management optimizes battery performance and lifetime Field programmable sequential start-up 2 to 99 seconds Hot swappable fan design Optional Redundant fan design Applications – Networking – Data centers – Telecommunications – Medical – Banking – Industrial 29 Confidential PPT_UPS_Generic_EN_V6 DPS Series 60/80/100/120kVA 160/200kVA 300/400kVA 1950 mm 1950 mm 1695 mm 865 mm 975 mm 865 mm 30 Confidential PPT_UPS_Generic_EN_V6 DPS Series Specifications Model DPS 60 DPS 80 DPS 100 DPS 120 DPS 160 DPS 200 DPS 300 DPS 400 Power Rating 60kVA / 54kW 80kVA / 72kW 100kVA / 90kW 120kVA / 108kW 160kVA / 144kW 200kVA / 180kW 300kVA / 270kW 400kVA / 360kW Voltage 380/220, 400/230, 415/240 Vac (3 phase, 4-wire plus ground) Input Voltage Range 208~477 Vac* 242~477 Vac* Input Power Factor > 0.99 Current Harmonic Distortion < 3% (full load) Output Voltage 380/220, 400/230, 415/240 Vac (3 phase, 4-wire plus ground) Output Voltage Regulation ± 1% (static) Interface RS232 x 1, Smart slot x 2, Dry contact output x 6, Dry contact input x 2, Parallel port x 2, Battery cabinet temperature sensor x 4, REPO x 1 Parallel Link Up to 4 units Up to 8 units AC-AC: Up to 96% ECO mode: Up to 99% Efficiency WxDxH (mm) Weight (kg) RS232 x 1, Smart slot x 2, Dry contact output x 6, Dry contact input x 2, Parallel port x 2, Battery cabinet temperature sensor x 4, Battery status detection x 1, REPO x 1 520 x 975 x 1695 300 330 360 390 850 x 865 x 1950 1600 x 865 x 1950 697 1335 * When input voltage is 208~300 / 242~324 Vac, the sustainable loading is from 70% to 100% of the UPS capacity. 31 Confidential PPT_UPS_Generic_EN_V6 Delta UPS – Modulon Family Three Phase Modular Online UPS - Up to 800 kW online UPS NH Plus Series DPH Series 20 - 120kVA 25 - 200 kW 32 Confidential PPT_UPS_Generic_EN_V6 Modular Design 20KVA 60KVA 100KVA 120KVA Modular design enables: •Easy expansion for the system •Easy spare part management •Easy maintainability in the field 33 Confidential PPT_UPS_Generic_EN_V6 NH Plus Series 20-120 kVA Hot-swappable function providing uninterruptible power during module replacement. N+X parallel reduncancy(up to 4 units, max. 480kVA) for reliability and flexibility, w/o extra hardware. High input power factor (pf > 0.99) and low harmonic distortion (iTHD < 3%). 94% high efficiency saving operation cost. Inbuilt automatic and manual bypass switch. Inbuilt SRAM recording maximum 500 real-time event logs. Multi-language LCD display and status LED indicators Compatible with generator installation. 6 configurable UPS status dry contact outputs. Optional kit for monitoring battery cabinet temperature. Applications – Networking – Data centers – Telecommunications – Medical – Banking – Industrial 34 Confidential PPT_UPS_Generic_EN_V6 NH Plus Series Specifications Model Power Rating* NHP-20K NHP-40K NHP-60K NHP-80K NHP-100K NHP-120K 20kVA /18kW 40kVA /36kW 60kVA /54kW 80kVA /72kW 100kVA/90kW 120kVA/108kW Voltage 380/220, 400/230, 415/240 (3 phase, 4-wire plus ground) Input Voltage Range 208 ~ 477 Vac (line-line) / 120 ~ 276 Vac (line-neutral)** Input Power Factor > 0.99 Input Current Harmonic Distortion < 3% (full load) 380/220, 400/230, 415/240 (3 phase, 4-wire plus ground) Other rating is available in another cabinet (I/P and O/P transformer is included) Output Voltage Connection Interface Hard wire (terminal block) RS232 x 1, SNMP slot x 2, Dry contact output x 6, Dry contact input x 2, Parallel port x 1, Battery cabinet temperature sensor x 4, Battery cabinet status detection x 1, Remote emergency power off x 1 Parallel Link Up to 4 units. Maximum 480 kVA External Battery Cabinet Optional WxDxH (mm) Weight (kg) 520 x 910 x 1165 112.5 128 230 520 x 975 x 1695 260 350 * Subject to reconfiguration of the UPS; Delta provides the configuration service. 35 ** When input voltage is 208~300/120~173 Vac, the sustainable loading is from 70% to 100% of the UPS capacity. Confidential 380 PPT_UPS_Generic_EN_V6 DPH Series 25-200 kW Advanced fault tolerance design achieved by self redundancy to guarantee operation continuity Self-synchronization of power and control modules for continuous on-line operation even in the event of control module failure to avoid downtime caused by single point failure Hot-swappable key modules and components to ensure Mean Time To Repair (MTTR) close to zero Vertical expansion from 25kW to 200kW supporting N+X redundancy in a single rack enclosure to save footprint Full rated power (kVA=kW) to maximize power availability High operating efficiency of 95% at 30% light load and 96% from 50% load resulting in marked energy cost savings Low harmonic pollution (iTHD<3%) to reduce upstream investment costs and meet demanding power requirements Applications – Data centers – Telecommunications – Network – Banking – Industrial 36 Confidential PPT_UPS_Generic_EN_V6 DPH Series Specifications Model Power Rating* 25 50 75 100 125 150 175 200 25kVA/kW 50kVA/kW 75kVA/kW 100kVA/kW 125kVA/kW 150kVA/kW 175kVA/kW 200kVA/kW Voltage 380/220, 400/230, 415/240 (3 phase, 4-wire plus ground) Input Voltage Range 176~276 / 305~477 V (When input voltage is 140/242~176/305 Vac, the sustainable loading is from 60% to 100% of the UPS capacity) Input Power Factor > 0.99 Input Current Harmonic Distortion < 3% (when input harmonic distortion is less than 1%) Output Voltage 380/220, 400/230, 415/240 Vac (3 phase, 4-wire plus ground) Interface Parallel port x 2, Smart slot x 2, Dry contact output x 6, Dry contact input x 6, SNMP card x 2, Battery dry contact x 6 Parallel Link Up to 4 units. Maximum 800 kW External Battery Cabinet Optional WxDxH (mm) Weight (kg) 600 x 1090 x 2000 382 414 446 478 510 542 574 606 37 Confidential PPT_UPS_Generic_EN_V6 Delta UPS Product Application Matrix 38 Confidential PPT_UPS_Generic_EN_V6 Product Application Matrix Agilon Configuration 1:1 Amplon VX- 0.6 kVA (line-interactive) N Series 1-3 kVA (on-line) N Series 6-12 kVA (on-line) R Series 1-3 kVA (on-line) GAIA Series 1-3 kVA (on-line) RT Series 5-10 kVA (on-line) O O O O O O O O O O O O E I E Configuration 3:1 Configuration 3:3 Rack mountable Stand alone O O O O Isolation transformer Backup ” Home and office * Small enterprise, IT and medical ** I I,E O O I,E O O O O Medium enterprice, telecom, IT, media *** O O O O Heavy i ndustry, telecom, IT, defence, industry and building automation **** ”I: internal battery, E: external battery * PCs, laptops, modems, printers, WiFi and audio equipment ** Computers, servers, networking, medical control and diagnostics, education, banking, info kiosks, industrial automation *** Telecom base stations, data centers, backbone networks, broadcasting, projection systems **** Telecom centers, data centers, medical equipment at hospitals, government use, automatic control, oil, gas and power utilities, industrial equipment, automation and control 39 Confidential PPT_UPS_Generic_EN_V6 Product Application Matrix Ultron Modulon HPH Series 20-40kW (on-line) DPS Series 60-400kVA (on-line) NH Plus Series 20-120kVA (on-line) DPH Series 20-200kW (on-line) O O O O O O O O O E I, E E E E O O O O O O O O O O O EH Series 10-20kVA (on-line) Configuration 1:1 Configuration 3:1 O Configuration 3:3 Rack mountable Stand alone Isolation transformer Backup ” Home and office * Small enterprise, IT and medical ** Medium enterprice, telecom, IT, media *** Heavy i ndustry, telecom, IT, defence, industry and building automation **** ”I: internal battery, E: external battery * PCs, laptops, modems, printers, WiFi and audio equipment ** Computers, servers, networking, medical control and diagnostics, education, banking, info kiosks, industrial automation *** Telecom base stations, data centers, backbone networks, broadcasting, projection systems **** Telecom centers, data centers, medical equipment at hospitals, government use, automatic control, oil, gas and power utilities, industrial equipment, automation and control 40 Confidential PPT_UPS_Generic_EN_V6 Delta UPS Management Software UPSentry 2012 InsightPower Manager InsightPower Client Shutdown Agent 2012 41 Confidential PPT_UPS_Generic_EN_V6 Management Software – UPSentry 2012 Advantages • Manage remote and local UPS in real-time • Shutdown/wakeup multiple servers in various operating systems • Shutdown unattended operating systems and save files • Provide multi-lingual (English, French, German, Spanish, Portuguese, Russian, • • • • Italian, Polish, Chinese and Japanese) Support Windows hibernation feature Be compatible with RS232 and USB protocols Support SNMP get, set and trap commands Equip a built-in mini Web server Operating Systems supported • Windows XP-sp2, Vista, 7, 8 • Windows 2003, 2008, 2012 • Windows 2008 Server Core, • Hyper-V 2008 R2 • Linux OpenSUSE 11.4 • Linux ubuntu 10.04 • Linux Fedora 3.1.9 • CentOS 5.8 • Citrix XenServer 6.0.0 • Linux KVM Confidential Download Site: http://59.125.232.140 42 PPT_UPS_Generic_EN_V6 Management Software – UPSentry 2012 Display: Real-time monitoring Multiple views formats: Meters and gauges, block diagram, lamp alarms, graph chart FlexAction: Shutdown Event log Network broadcast External command file Audible alarm E-mail SMS(Short Message) Pager SNMP trap Receptacle control Event Tracking: Records of date/time/description of power events Data logging for analyzing power quality Schedule: Shutdown/Restart Quick test, deep battery test Outlet bank control Confidential PPT_UPS_Generic_EN_V6 Management Software – InsightPower Manager 3F 2F Network InsightPower Manager Service SNMP InsightPower Manager Monitor Advantages: Centralized UPS management system Supports RS232, RS485 and SNMP connections Supports database connection through ODBC Hierarchical design, allows unlimited nodes Client/Server design, multiple remote Monitor programs can connect to a Service program Programmable actions(FlexAction) Batch SNMP configuration Remote and local UPS real-time management Generate routine reports Schedule shutdown/restart and test UPS Able to save the users operation log, UPS event log and historical parameters in database SNMP RS232/485 Operating System supported: Microsoft Windows 2000, XP, 2003, Vista, 2008, Win7 SNMP RS232/485 InsightPower Manager Monitor Confidential PPT_UPS_Generic_EN_V6 Management Software – InsightPower Manager Display: Real-time monitoring Multiple views formats: Meters, block diagram, lamp alarms, graph chart Confidential FlexAction: Event Tracking: Records of date/time/description of power events Data logging for analyzing power quality Generate reports Event log Network broadcast Audible alarm E-mail SMS PPT_UPS_Generic_EN_V6 Management Software – InsightPower Client Advantages: New generation UPS shutdown management software Supports SNMP protocol Multi-servers shutdown/wakeup with SNMP card Works with SNMP card seamlessly Unattended operating systems shutdown and files saving Support hibernation feature in Windows 2000/ XP Programmable actions(FlexAction) Remote UPS real-time management Run time: Network Clien t Clien t Power fail Battery capacity UPS battery low Schedule shutdown Clien t Reactions: HUB UPS Confidential SNMP card Audible alarm Network broadcast E-mail SMS External command file PPT_UPS_Generic_EN_V6 Management Software – InsightPower Client Schedule: Weekly and specific date Shutdown and restart Quick battery test Deep battery test Display: Real-time monitoring Multiple views formats: Meters and gauges, lamp alarms, graph chart Fast look up data log by cursor Generate statistic values automatically Event Tracking: Records of date/time/description of power events Data logging for analyzing power quality Smart Shutdown: Shutdown the operating system gracefully while users press the Smart Shutdown button from SNMP card Use the low battery run time settings when Smart Shutdown initiates Confidential PPT_UPS_Generic_EN_V6 Management Software – Shutdown Agent 2012 Advantages: Support SNMPv1, v3 trap Provide web interface through HTTP and HTTPS Provide the batch configuration to deploy settings at a finger click Forward SNMP trap to extend protecting up to 255 servers Support up to 32 input trap sources for redundant (logical OR) and parallel (logical AND) application Provide console configuration for basic system parameters setup Support Windows 32/64 bits setup programs Operating Systems supported: Confidential Windows XP-sp2, Vista, 7, 8 Windows 2003, 2008, 2012 Windows 2008 Server Core, Hyper-V 2008 R2 Linux OpenSUSE 11.4 Linux ubuntu 10.04 Linux Fedora 3.1.9 CentOS 5.8 VMWare ESXi 4.1, 5 Citrix XenServer 6.0.0 Linux KVM PPT_UPS_Generic_EN_V6 UPS Connectivity 49 Confidential PPT_UPS_Generic_EN_V6 Management Peripherals For SMART Slot SNMP Card • Remote control and diagnose UPS • Monitor all the UPS information in the network. SNMP IPv6 Card • Remote control and diagnose UPS • Monitor all the UPS information in the network. ModBus Card Translates the UPS RS232 protocol into another RS232 and RS422/485. Relay I/O Card Information on UPS status presents 6 contact closures. 50 Confidential PPT_UPS_Generic_EN_V6 For MINI Slots Mini Cards are specially designed for UPS equipped with “MINI Slot”. Mini SNMP Card Mini ModBus Card Mini USB Card Mini Relay I/O Card Mini TVSS Card 51 Confidential PPT_UPS_Generic_EN_V6 EnviroProbe Easy to manage Monitors temperature and humidity of the environment Backlight LCD display 4 contact closure inputs for monitoring other environmental devices Convenience Quickly check any area via internet browser InsightPower Manager software provides remote monitoring and recording Support RS232 or RS485 communication Flexibility Support SNMP communication protocol Cascade up to 10 EnviroProbes via RS485 52 Confidential PPT_UPS_Generic_EN_V6 Summary Power range from 600VA - 4000 kVA Agilon : <1 kVA Amplon: 1 - 12 kVA Ultron: 10 - 500 kVA Modulon : 20 - 120 kVA Modular UPS Wide range of applications PC & Peripherals Sever & Networking Data Center, Facility & Industrial Modular system Delta UPS provides Full range of uninterruptible power protection. High efficiency for operation cost savings. High reliability and performance. ISO14001, RoHS compliance. World wide service. 53 Confidential PPT_UPS_Generic_EN_V6 Mission Critical Infrastructure Solutions(MCIS) The Power Behind Competitiveness To learn more about Delta MCIS, please visit www.deltapowersolutions.com