Kryolab
Transcription
Kryolab
Laboratory Refrigerators - Freezers FRL - FCL - Kryolab - Kryos Series Life Science Business Unit AS - Biomedical Equipment Division AngelantoniIndustrieSpAmanufacturesawiderangeof refrigeratedcabinetsandcombinedrefrigerator-freezertoable meetthedifferentneedsoftemperature,dimensionsandstorage capacityforlaboratory,hospitalsandpharmaceuticalindustries. FRL Series /Optional · · · · · Temperaturechartrecorder 23-50mmporthole Shelf Drawer PT100Probe FCL Series /Optional · · · Temperaturechartrecorder Alarmsystem 23-50mmporthole Kryolab Series /Optional · · Temperaturechartrecorder Alarmsystem Kryos Series /Optional · · · · · Temperaturechartrecorder Bioguard®Access Software PT100Probe SerialInterface Life Science Business Unit _ AS Division Laboratory Refrigerators - Freezers FRL - FCL - Kryolab - Kryos Series Easytocleanandtouse. Maximumconvenience. Reliabilityofalarmsystem. Flexibilityinthestoragesystem. Life Science Business Unit _ AS Division Laboratory Refrigerators - Freezers FRL & FCL Series BasicLine. Technicalfeatures Refrigerators/FRLeFRLMModels Structure/Modelsfullymetallicphosphatecoatedsteelplate. Whiteepoxypowderpaintingtoensuredurability. Internalchamberabrasionproofspecialplastic. FRLmodelsareequippedwithadjustablefeetforproperpositioning.FRLMmodelsare providedwithrollersforeasymovingandadjustablefeetforpositioning. Door/Madewithsamefeaturesoftheframe,withvariablehingeaccordingtotheneeds. Externalkeylock. Possibilitytohavetripleglassdoor. ShelvesGrid/Shelvesadjustableinheight. Innerlamp/Dooropencourtesylightforglassdoormodelsonly. Insulation/InjectedHCFC-freefoamedpolyurethane.The50mmthickness. Coolingsystem/Completelysealed,silentandhighlyefficienthermeticcompressorusing ecologicalrefrigerants. Ventilatedaircondenser. Internalventilatedevaporator. Regulationandcontrolsystem/FRL:Externalelectronicthermostatfortemperature adjustment.Electronicdigitalindicatorinstalledonthedoor. FRLM:MicroprocessorcontrolboardHTWL. Acousticandvisualhighandlowtemperaturealarmsandacousticalarmsystemforopendoor. Remotealarmscontacts. Rechargeableback-upbattery. CombinatedRefrigeratorsandFreezer/FCLModels 01 4 Structure/FCLmodelsfullymetallicphosphatecoatedsteelplate. Whiteepoxypowderpaintingtoensuredurability. Internalchamberabrasionproofspecialplastic. FCLmodelsareequippedwithadjustablefeetforpositioning. Door/N°2doorsmadewithsamefeaturesoftheframe,withvariablehingeaccordingtothe needs.Externalkeylock. Shelves-DrawersGrid/Shelvesadjustableinheightandtransparentplasticbasketsfor refrigeratorscompartmentandplasticdrawers. Innerlamp/Dooropencourtesylightforrefrigeratorcompartmentonly. Insulation/InjectedHCFC-freefoamedpolyurethane. The40mmthicknessforrefrigeratorcompartmentand80mmforfreezercompartment. Coolingsystem/Completelysealed,silentandhighlyefficienthermeticcompressorusing ecologicalrefrigerants. Ventilatedaircondenser. Internalventilatedevaporator(forrefrigeratorcompartmentonly). Regulationandcontrolsystem/Internaltemperatureforbothcompartment. Eachtemperaturecompartmentiscontrolledbyelectronicregulator. Technicalspecifications FRL Model 260 V 160 V Nominal capacity (l) 360 V 360 +1 / +15 Temperature range (°C) +2 / +14 0,8 / 1,2 (porta in vetro) 0,8 / 1,5 (porta in vetro) 1,5 R600a Refrigerant External dimensions (mm) 600×620×850 (1070) 600×610×1250 (1470) 600×610×1640 (1860) 750×730×1640 (1860) Internal dimensions (mm) 495×455×675 470×440×1062 470×440×1452 590×560×1452 58 / 60 62 / 75 72 / 90 86 / 105 Overall weight with standard packaging (Kg) Noise level (dbA) Model 43 FRL M 160 V-M Nominal capacity (l) 260 V-M 360 V-M 500 +2 / +14 +1 / +15 208 - 230V /50Hz Supply voltage (V)* Maximum absorbed current (A) 500 V-M 360 260 160 Temperature range (°C) 0,8 / 1,5 (porta in vetro) 0,8 / 1,2 (porta in vetro) 1,5 R600Aa- R134a Refrigerant External dimensions (mm) 600×620×1070 600×610×1470 600×610×1860 750×730×1860 Internal dimensions (mm) 495×455×675 470×440×1062 470×440×1452 590×560×1452 58 / 60 62 / 75 72 / 90 86 / 105 Overall weight with standard packaging (Kg) Noise level (dbA) Model 43 FCL 400/2 TN-2TS V 300/2 TN-2TS V Nominal capacity refrigerator compartment (l) 215 260 100 Nominal capacity freezer compartment (l) +1 / +9 Temperature range refrigerator compartment (°C) -15 / -32 Temperature range freezer compartment (°C) 208 - 230V /50Hz Supply voltage (V)* 2 Maximum absorbed current (A) R600a Refrigerant External dimensions (mm) 595×610×2020 595×610×2215 Internal dimensions refrigerator compartment (mm) 520×465×885 520×465×1075 Internal dimensions freezer compartment (mm) 425×405×600 425×405×600 98 Overall weight with standard packaging (Kg) Illustration,descriptionandtechnicaldatamaybechangedwithoutnotice./(*)230V/60Hzand115V/60Hzmodelsarealsoavailable. 02 03 01. 02. 03. 110 48 Rumorosità (dbA) 5 500 208 - 230V /50Hz Supply voltage (V)* Maximum absorbed current (A) 500 V 260 160 FRL360V-Mwithoptionals. FCL300and400withoptionals. FRL360V-Mwithglassdoorwithoptionals. Life Science Business Unit _ AS Division Laboratory Refrigerators - Freezers Kryolab & Kryos SerieS BasicLine. Technicalfeatures Freezers/KryolabeKryosModels 01 02 Structure/Modelsfullymetallicphosphatecoatedsteelplate.Whiteepoxypowderpainting toensuredurability.Internalchamberinabrasionproofspecialplastic/aluminiumsheet. Availableverticalandchestmodel. Door/Madewithsamefeaturesoftheframe,withvariablehingeaccordingtothe needs(verticaltypeonly).Externalkeylock.KRYOSPLUSmodel:doorisequippedwith BIOGUARD®apropertytransponderaccesscontrolsystemthatopensthedoorwhenan authorizeduserpresentsabadgeortag.Inthiswayanyoperationrelevanttotheuseofa freezeriscompletelyunderremotecontrol. Baskets-Drawers/Basketsforchestmodelandplasticdrawersforverticalmodelswillbe supply. Innerlamp/Dooropencourtesylightforchestmodelonly. Insulation/InjectedHCFC-freefoamedpolyurethane. KRYOLABV(verticalmodel)andKRYOSSH(chestmodel)-70/100mmthickness. KRYOLABH(chestmodel)-The60mmthickness KRYOSSV(verticalmodel)-The70mmthickness. Coolingsystem/Completelysealed,silentandhighlyefficienthermeticcompressorusing ecologicalrefrigerants.Ventilatedaircondenser.Internalevaporator. Regulationandcontrolsystem/KRYOLAB:externalthermostatforthetemperature control.Externalelectronicdigitalindicatorforthetemperaturevisualization. KRYOSSH:electronicdigitaldisplayregulator/indicator,placedonthefrontcontrolpanel andcompletewith: · · · · Workingtemperaturesetting ON/OFFalarmsystembutton Alarmsystempilotlights Temperaturedigitaldisplay. Electroniccardcontrol,placedonthecontrolpanel. Audibleandvisualalarmsystem,independentfromthecontrolsystem. Themaximumalarmvaluesarefactoryset. Thesystemisautonomouswithadedicatedrechargeablebattery. KRYOSSV:microprocessorcontrollerE2003,withtwoindependentsections,thefirstone tosetandcontroltemperature,thesecondonetomanagethealarmsystemanddisplay temperature.Rechargeablebufferbattery(12V,2Ah)tomaintainthealarmsystemonfor 48hoursincaseofpoweroutage. Configuredforaremotereplicationofalarms. OptionalRS485/422/232serialinterface. OptionalCRYOLOGsoftwareformonitoringofequipmentparametersandalarms. 6 Technicalspecifications Horizontal Models Vertical Models KRYOLAB Model 500 H 300 H Nominal capacity (l) 300 300 V 300 500 1,3 1,1 1,6 500 Temperature range (°C) -15 / -30 208 - 230V /50Hz Supply voltage (V)* 1 Maximum absorbed current (A) R600a / R134a R600a External dimensions (mm) 1000×760×915 R600Aa / R134a 1650×810×915 600×620×1645 (1865) 745×780×1725 (1945) Internal dimensions (mm) 860×520×720 1445×500×670 410×410×1370 615×550×1500 68 90 95 110 Refrigerant Overall weight with standard packaging (Kg) Noise level (dbA) 43 Vertical Models Horizontal Models KRYOS Model 500 SV - 500 SV PLUS 500 SH 500 Nominal capacity (l) -25 / -50 Temperature range (°C) Supply voltage (V)* -20 / -43 208 - 230V /50Hz 2,2 Maximum absorbed current (A) 2 CARE 50 R404a External dimensions (mm) 1650×750×915 745×820×1965 Internal dimensions (mm) 1445×550×670 615×550×1500 Overall weight with standard packaging (Kg) 100 143 Noise level (dbA) <60 47 Refrigerant Illustration,descriptionandtechnicaldatamaybechangedwithoutnotice. (*)230V/60Hzand115V/60Hzmodelsarealsoavailable. 03 04 01. 02. 03. 04. 7 500 V Kryolabwithoptionals. Kryolab500V. KRYOLAB500withchartrecorder. Kryos500SH. Life Science Business Unit _ AngelantoniIndustrieSpA-ASBiomedicalDivision Loc.Cimacolle,464 06056MassaMartana(PG)Italy telephone+39.075.89551/telefax+39.075.8955312 [email protected] www.angelantoni.it Copyright©2011AngelantoniIndustrieSpA/Rev.00-05/10/2011–Illustration,descriptionandtechnicaldatamaybechangedwithoutnotice.