Eurosurgical Silimed Brochure

Transcription

Eurosurgical Silimed Brochure
Plastic and Reconstructive Surgery
Ref No: 00107
Body Implants, Tissue Expanders
& Facial Implants
Product Catalogue No 6 (October 2008)
Introduction
SILIMED, a company present in more than fifty countries
of the five continents, has the largest line of products
in the market, manufactured according to the highest
standard of quality. They are all made with FDA-registered,
medical-grade silicone.
Contents
Gluteal Implants
3–6
Calf Implants
7–8
Pectoral Implants
9 – 12
Facial Implants
13 – 18
Silicone Block
19 – 20
Hand Surgery
21 – 22
Silicone Scar Therapy
23 – 26
Tissue Expanders
27 – 38
Our manufacturing process is in strict compliance with
the Good Manufacturing Practices determined by ANVISA
and FDA, and our Quality Management System is certified
according to the ISO 9001:2000, ISO 13485:2003 and ISO
13485:2003 standards (including the requirements from
Canadá) and our products bear the CE mark.
Every implant has its serial number, brand and size engraved
which makes its identification possible at any time. The
individual serial number allows our company to have
control not only of the products sold, but also of all the
material and techniques used during the manufacturing
process. This characteristic reflects the seriousness and
professionalism present in our company’s activities.
Body Contour Implants
Silimed offer the widest range of silicone implants for
all areas of body contour surgery. With a long history of
working with respected surgeons throughout the world
on the development of implants for gluteal surgery, calf
enhancement, pectoral implantation and facial surgery.
The body contour implants offer a wide range of low-bleed
shells, silicone shore and strengths to suit the variety of
requirements and options of shell surface technology.
Merrow Business Park, Guildford, Surrey GU4 7WA
T: +44 (0)1483 456007 F: +44 (0)1483 456008
E: [email protected] W: www.eurosurgical.co.uk
Gluteal Implants
Gluteal Implants
Gluteal implant placed in the retromuscular pocket in
the so called subgluteal cellular space.
4) Implant
1) Incision of the skin
5) Gluteal medium
6) Gluteal maximus
7) Sciatic nerve
2) Subcutaneous dissection
Templates are available with the shape of the base of
the gluteal implants. These templates are meant to
help the surgeon in pre-surgery evaluation to select
the implant that best suits each particular case.
04 – Textured Silicone Implants
03 – Gluteal Implants
3) Muscle incision
Gluteal Implants
Gluteal Implants
OVAL BASE
ROUND BASE
1) Low Projection Opaque Surface
1) Single Projection Smooth Surface
A
B
C
A
Ref
B
Ref
Vol
cm3
cm
A
B
Vol
cm3
C
cm
A
B
13960-200
200
14.0
9.5
2.7
10910-200
200
10.6
3.7
13960-250
250
14.5
9.8
3.1
10910-220
220
10.7
3.8
13960-300
300
14.9
10.4
3.5
10910-240
240
10.9
3.9
13960-350
350
15.2
10.9
3.8
10910-270
270
11.4
3.9
13960-400
400
15.4
11.2
4.3
10910-300
300
11.7
4.0
13960-450
450
15.8
11.7
4.5
10910-330
330
12.1
4.1
13960-500
500
16.2
12.1
4.6
10910-360
360
12.3
2.8
2) High Projection Opaque Surface
A
C
Ref
Vol
cm3
cm
05 – Gluteal Implants
A
B
C
13961-200
200
13.7
9.2
2.8
13961-250
250
14.0
9.5
3.5
13961-300
300
14.3
9.7
3.8
13961-350
350
14.9
10.4
4.2
13961-400
400
15.2
10.9
4.6
13961-450
450
15.4
11.2
4.7
13961-500
500
15.8
11.7
4.8
06 – Gluteal Implants
B
Calf Implants
Calf Implants
CALF IMPLANT – SILICONE GEL – SMOOTH SURFACE
1) Asymetrical Base
SILIMED presents the widest range of calf implants in
the market, all designed by plastic surgeons. They are
made of a low-bleed silicone elastomer envelope filled
with biodesign high performance silicone gel, able to
reproduce the soft tissues allowing a better suitability
of the implant to the area involved. These implants are
indicated to correct the unevenness or irregularities
of the calf such as sequela of poliomyelitis, congenital
malformation, neurological diseases, traumatisms
and others. Although they have been designed to
reparatory surgery they have been increasingly used
in aesthetic surgery with excellent results.
Designed to get closer to the anatomy of the area thus
making the use of several implants unnecessary.
B
C
A
Ref
Vol
cm3
10410-085
Supplied sterile.
85
cm
A
B
C
15.0
4.7
2.4
10410-140
140
19.7
5.4
2.5
10410-180
180
23.1
5.8
2.6
Presented in several types as described below.
Calf implant placed below the aponeurosis of the medial
gastrocnemius muscle (figure 1).
A - Rear View / B – Side View
Fig 1.
IMPORTANT: Calf implants have a
‘small insertion pouch’ made of silicone
attached to one of the ends of the base to
help with insertion. To avoid damaging
the implants do not use any sharp
instruments (figure 2).
Designed according to its name with a symmetrical base
which allows the use of several implants at the same
time in order to achieve the desired relief.
B
C
A
Ref
A
Vol
cm3
B
cm
A
Fig 2.
Before using the product the surgeon should read the
instructions for use contained in the packaging.
B
C
10400-012
12
6.2
2.1
1.6
10400-030
30
10.2
3.0
1.9
10400-070
70
15.7
3.3
2.5
10400-090
90
19.5
3.2
2.3
10400-095
95
19.4
4.9
1.7
10400-120
120
26.6
3.4
2.5
10400-140
140
26.2
4.4
2.5
Note 1: Dimensions and volumes with approximate values.
08 – Calf Implants
07– Calf Implants
1. Incision in the skin
2. Incision of the aponeurosis of the
medial gastrocnemius muscles
3. Implant
4. Inner popliteal sciatic nerve
5. Soleus muscle
6. Posterior muscle
7. Tibiofibular
8. Medial gastrocnemius muscle
2) Symetrical Base
Pectoral Implants
Pectoral Implants
PECTORAL IMPLANT – SILICONE GEL
This implant is presented for the right side and left side.
The SILIMED pectoral implant is made of a low-bleed
silicone elastomer envelope and contains a definite volume
of high performance biodesign silicone gel, whose shape,
density and overall consistency have been developed to
resemble the human tissue corresponding to application.
The incision is made in the auxiliary region, which
should be wide enough (about 5cm) to allow the
insertion of the implant (figure 1).
Indicated for reparatory surgery in cases of patients with
deficiency in the pectoral region, such as congenital
pectoral aplasia, due to its good results the pectoral
implant has been increasingly used in aesthetic surgeries.
Supplied sterile.
The pocket is made under the pectoral muscle, undermining
but without removing it from the minor pectoral muscle.
The undermining should be interrupted 1cm or 2cm below
the areola otherwise the implant will be positioned too low,
which will result in a feminine appearance (figure 2).
The pocket should be carefully inspected to verify the
absence of remaining muscle fibres.
Using long pincers, secure the polyester rim of the
implant and introduce it into the pocket, positioning
it between the two pectoral muscles and making sure
that the angles of the implant are even with those of the
muscle (figure 2).
Fig 2. Undermining
and Introduction
Fig 3. Final Result Fig 4. Final Result
Before using the product the physician should read
the instructions for use contained in the packaging.
10 – Pectoral Implants
09– Pectoral Implants
Fig 1. Incision
Pectoral Implants
Pectoral Implants
SMOOTH SURFACE
TEXTURED SURFACE
A
A
B
B
C
C
Ref
Ref
Vol
cm
cm
3
10130-190 D
190
Vol
cm3
A
B
C
14.4
10.4
2.4
cm
A
B
C
20130-190 D
190
14.7
10.7
2.4
10130-190 E
190
14.4
10.4
2.4
20130-190 E
190
14.7
10.7
2.4
10130-230 D
230
15.8
11.7
2.6
20130-230 D
230
16.0
12.0
2.7
10130-230 E
230
15.8
11.7
2.6
20130-230 E
230
16.0
12.0
2.7
10130-300 D
300
16.5
12.2
2.9
20130-300 D
300
16.9
12.7
2.9
10130-300 E
300
16.5
12.2
2.9
20130-300 E
300
16.9
12.7
2.9
Presented in smooth or textured surfaces as shown.
Note 1: Dimensions and volumes with
approximate values.
Note 2: D = right, E = left
Templates are available with the shape of the
base of the pectoral implants. These templates
are meant to help the surgeon in pre-surgery
evaluation to select the implant that best suits
each particular case.
12 – Pectoral Implants
11– Pectoral Implants
IMPORTANT: Contains polyester reinforcement to help
with insertion.
Facial Implants
Facial Implants
CHIN IMPLANTS
MALAR IMPLANTS
I) Smooth Surface
II) Textured Surface
1) Malar
1) Chin Implant
A
B
B
C
C
Ref
A
cm
Ref
I
II
A
B
C
cm
20-025
20020-025
1
2.6
1.9
0.35
A
B
C
20-030
20020-030
2
3.1
2.3
0.41
20-032
20020-032
3
3.2
2.4
0.47
I
II
10-035
20010-035
1
3.5
1.6
0.7
10-045
20010-045
2
4.5
1.7
0.8
10-050
20010-050
3
4.8
1.7
0.8
10-055
20010-055
4
5.3
1.8
0.8
10-075
20010-075
5
7.5
1.9
0.8
2) Anatomical Malar
A
2) Anatomical Chin
C
B
B
Ref
cm
A
Ref
13– Facial Implants
cm
I
II
A
B
C
15-060
20015-060
1
6.1
1.4
0.6
15-065
20015-065
2
6.4
1.5
0.7
15-080
20015-080
3
7.9
1.5
0.8
I
II
A
B
C
25-40D
20025-40D
1
2.0
4.0
0.42
25-40E
20025-40E
1
2.0
4.0
0.42
25-45D
20025-45D
2
2.3
4.3
0.42
25-45E
20025-45E
2
2.3
4.3
0.42
25-50D
20025-50D
3
2.5
5.0
0.45
25-50E
20025-50E
3
2.5
5.0
0.45
14 – Facial Implants
C
Facial Implants
Facial Implants
NASAL DORSUM
EYELID SUSPENSOR AND EAR IMPLANT
I) Smooth Surface
II) Textured Surface
1) Eyelid Suspensor Implant
This implant is made of soft silicone elastomer,
reinforced at the fixation with the eyelid. It is indicated
in cases of “Severe Palpebral Ptosis”, when the capacity
of the eyelid elevator muscle is diminished.
1) Nasal Dorsum
C
B
A
A
Ref
cm
I
II
50-040
20050-040
50-055
20050-055
A
B
C
1
4.0
0.8
0.2
2
5.6
0.9
0.2
Ref
cm
60-013
2) “L” - shaped Nasal
B
B
C
A
B
C
1.30
0.35
7.0
A
2) Ear
D
C
A
Shore
I
II
70-060
20070-060
A
20
50
B
cm
A
B
2.0
C
D
C
Ref
cm
3.2
4.0
A
B
C
20080-053D
5.2
3.1
1.2
20080-053E
5.2
3.1
1.2
0.35
16 – Facial Implants
15– Facial Implants
Ref
Facial Implants
Facial Implants
NOSTRIL RETAINER
NOSTRIL RETAINER
It has a functional anatomic format and can be sectioned
by adjusting the length according to requirements.
The nostril retainer helps to hold the septum in a
vertical position, allows for nasal breathing immediately
after the operation without blocking the flow of air, is
painless and non-traumatic, easy to clean and sterilise,
erases the memory of ectopic cartilage and maintains
constant results.
Supplied sterile in individual packaging.
17– Facial Implants
Provided in two versions; one simple (a) and another
option with lateral fixation patches (b) which may be
used during the first post-surgery phase to prevent the
displacement of the product and with a white dot to
indicate the correct positioning as described below.
Before using the product the physician should read
the instructions for use contained in the packaging.
B
B
A
A
*Conceived by Dr José Lauro de Fonseca.
Ref
mm
a
b
A
B
C
1170-018
1171-018
1170-019
1171-019
1
1.80
2.30
0.70
2
1.90
2.40
0.80
1170-020
1170-021
1171-020
3
2.00
2.50
0.90
1171-021
4
2.10
2.60
1.00
1170-022
1171-022
5
2.20
2.70
1.05
1170-023
1171-023
6
2.30
2.80
1.10
1170-024
1171-024
7
2.40
2.90
1.20
1170-025
1171-025
8
2.50
3.00
1.30
1170-026
1171-026
9
2.60
3.10
1.40
1170-027
1171-027
10
2.70
3.20
1.50
1170-028
1171-028
11
2.80
3.30
1.60
1170-029
1171-029
12
2.90
3.40
1.70
1170-030
1171-030
13
3.00
3.50
1.80
Note: Dimensions with approximate values.
18 – Facial Implants
Made of medical-grade silicone elastomer it is
recommended for all age groups and types of noses
(black, Caucasian, oriental).
C
It is indicated for septoplasty surgeries and on
rhinoplasty primary surgeries (unilateral labial fissures).
It assists in the correct positioning of the anatomic
structures committed located between them and the
nostril septum and permits the normal growth of the
facies and the nose.
C
Designed for prophylaxis of stenosis and
cicatricial contractures.
Silicone Block
Silicone Block
SHEETS AND BLOCKS
SHEETS AND BLOCKS
The silicone block is meant to substitute or augment
soft or cartilaginous tissues such as the chin and nose.
Being moldable it is designed for carving any type of
solid implant.
2) Coloured – Double Consistency
It is made of a silicone elastomer which is homogenous,
pure or reinforced, translucent, colourless or pigmented.
It has a smooth surface and is vulcanised to obtain the
desired or specified degree of hardness.
Supplied non-sterile
A
C
B D
Ref
Shore
Presented with different degrees of hardness as
described below.
A
1) Standard
B
C
1203-140
Pink
10
50
10
50
B
C
D
14.0
1.5
4.5
1.2
14.0
1.5
4.5
1.2
3) Coloured – Single Consistency
Ref
Shore
A
19– Silicone Block
White
A
cm
A
B
C
1200-010
Super
Soft
12
12.0
7.0
1.5
1200-030
Soft
25
12.0
7.0
1.5
1200-050
Medium
50
12.0
7.0
1.5
1200-080
Hard
70
12.0
7.0
1.5
Before using the product the physician should read
the instructions for use contained in the packaging.
B
A
C
Ref
Shore
A
cm
A
B
C
1202-140
White
50
14.0
6.0
1.2
1204-140
Pink
50
14.0
6.0
1.2
Note: Dimensions with approximate values.
20 – Silicone Block
A
1201-140
cm
Hand Surgery
Hand Surgery
PHALANGEAL JOINT
TENDON SPACER
Made of silicone elastomer. It is indicated in arthroplasty
surgeries for implant of the metacarpal-phalangeal,
proximal interphalangeal and distal interphalangeal joints.
Made of silicone elastomer. This is a passive shaper for
temporary use, meant to reconstitute the tendons of the
hand in cases of tendinous adherences and scars, absence
of the sheath or rupture of the tendon. Supplied Sterile.
1) Oval Section
1) Oval Section
C
C
D
B
B
A
Ref
A
cm
Ref
I
cm
I
2001-00
00
A
B
C
2051-3
3
240.0
3.0
1.5
2051-4
4
240.0
4.0
2.0
A
B
C
D
2051-5
5
240.0
5.0
2.5
7.8
25.5
3.4
2.8
2051-6
6
240.0
6.0
3.0
2001-0
0
9.5
29.5
4.3
3.3
2001-1
1
11.5
32.1
5.5
4.8
2001-2
2
11.8
36.8
5.9
5.2
2001-3
3
12.8
42.6
6.6
5.4
2001-4
4
13.8
49.6
6.9
5.9
2001-5
5
14.7
54.1
8.2
6.3
2001-6
6
15.1
61.3
8.4
6.4
2001-7
7
15.9
67.4
9.7
6.6
2) Round Section
B
A
Ref
21– Hand Surgery
I
Before using the product the physician should read
the instructions for use contained in the packaging.
A
B
2052-2
2
300.0
2.0
2052-3
3
300.0
3.0
2052-4
4
300.0
4.0
2052-5
5
300.0
5.0
2052-6
6
300.0
6.0
2052-7
7
300.0
7.0
22 – Hand Surgery
cm
Silicone Scar Therapy
Silicone Scar Therapy
MEDGEL
MEDGEL
Silicone Gel for Scar Treatment
1) Plate
Medgel is a biocompatible medical-grade silicone gel.
B
A
Ref
Intended for the prevention of hypertrophic scars, for
treatment and control of old or recent scars resulting
from surgery and keloid scars.
cm
A
Medgel comes in the following models:
Plates for wide or widespread scars (eg burns)
Strips for linear scars (eg abdominoplasty, reduction
mammoplasty; Caesarean births and cardiac surgery)
Discs for areolar scars (eg breast reduction or
augmentation and removal of cysts)
Inverted ‘T’ for mammary reductions (eg reduction
mammoplasty)
Gel for uncovered areas (eg hands, face, neck) and areas
not accessible by the medgel plate (eg behind the ear).
23– Silicone Scar Therapy
Before using the product the physician should read
the instructions for use contained in the packaging.
B
1240-010 I1
10
10
1
1240-010 H
10
10
6
2) Strip
B
A
Ref
QTD
cm
Supplied non-sterile in individual or multiple packaging.
IMPORTANT: Not to be applied to open wounds,
unsound tissue and on infected organs.
QTD
1240-011 I1
A
B
30
2.0
1
1240-011 I2
30
2.0
2
1240-011 H
30
2.0
12
24 – Silicone Scar Therapy
Its easiness of use offers comfort to the patient when
it is in contact with the skin. It is permeable to water
vapour, impermeable to micro-organisms, its elasticity
enables free joint movement and it is non-antigenic and
essentially non-toxic.
Silicone Scar Therapy
Silicone Scar Therapy
MEDGEL
MEDGEL
3) Strip
5) Inverted ‘T’
B
B
A
A
Ref
QTD
Ref
QTD
cm
1240-016 I1
cm
A
B
10
5
1
4) Disc
1240-013 I2
A
B
34
9.5
2
6) Gel
A
Ref
B
cm
QTD
cm
A
A
1230-015
B
1240-012 I2
7
2
1240-012 H
7
12
15
B
1
Note: Dimensions with approximate values.
26 – Silicone Scar Therapy
Ref
25– Silicone Scar Therapy
QTD
Tissue Expanders
Tissue Expanders
Made of a chemically and mechanically resistant smooth
or textured surface silicone elastomer envelope. The
indications are multiple, from mammary reconstruction
to the correction of burn sequelae, baldness surgery,
facial tumours and scars in general. Provided in two
types; expander for slow expansion with different valves
and intraoperative expander for fast expansion during
surgery with luer.
1) Round Valve
The references of the expanders are formed by the
association of the codes of the desired components with
the nominal volume. Ex: 250ml rectangular expander
with adult and child valve - ref 810-250-3 or auricular
16ml expander child valve – ref 841-016-1.
When the part has a specific differentiated used for the
left and right side, at the end of the reference add the
letter E (left) or D (right). Ex: 40ml auricular expander –
left side/child valve – ref 841-040 E1.
Some expanders are delivered with two or more valves.
Notwithstanding the above we must stress that expanders
are single use devices that must be discarded after use
together with the valves that have not been used.
Adult
base diameter: 34mm
Child
base diameter: 22mm
Note 2: Both have a resistant
radiopaque stainless steel disc to
prevent the needle from trespassing.
The needle must be introduced all the
way to the bottom perpendicular to
the valve.
Note 3: Take care not to damage the
tip of the needle while introducing
it as this could turn it into a hook,
leaving an opening in the septum
thus resulting in the reflux of the
injected liquid.
Supplied sterile.
Before using the product the surgeon should read the
instructions for use contained in the packaging.
28 – Tissue Expanders
27 – Tissue Expanders
Presented in several types as described below.
Tissue Expanders
Tissue Expanders
2) Cone Shaped Valve
5) Locating the Valve
Contains a ceramic cuvet to prevent
the needle from trespassing.
e. Marking the exact place
for the injection
f. Insert the needle, checking
whether it completely passes
the septum
11mm/base
3) Assembly Sequence
6) Luer Lock
Cut tube at required length without
passing the mark.
This luer accompanies
intraoperative expanders
and some expanders for slow
expansion as an external valve.
Fit the tube connected to the
expander into the free end of the
connection until it meets the tube.
4) Incorporated Magnetic Valve for Slow Expansion –
ref XXXX9
29 – Tissue Expanders
a. Silicone septum
b. Envelope reinforcement to
prevent folds
c. Magnetic disc with stabiliser
d. Magnetic finder
There are different templates
available with the base format of
the expanders. These templates
are meant to help the surgeon
make the pre-surgery evaluation
and select the expander that best
adapts to each case.
30 – Tissue Expanders
Dome diameter:
diameter 22mm
Tissue Expanders
Tissue Expanders
SMOOTH
SMOOTH
1) Rectangle / Smooth / Remote Valve
2) Round / Smooth / Remote Port
A
C
C
B
A
B
Ref
Ref
cm
I
31– Tissue Expanders
810-030
30
I
A
B
C
A
B
C
800-050
50
6.2
3.6
2.5
5.1
2.5
800-100
100
7.9
2.8
810-050
50
3.8
3.8
3.8
800-200
200
9.6
4.1
810-100
100
4.6
6.0
5.3
800-300
300
10.6
5.0
800-400
400
11.2
5.5
810-105
105
4.1
8.7
3.3
810-160
160
5.1
11.0
3.8
800-500
500
12.2
6.2
810-200
200
5.0
6.0
7.0
800-600
600
13.2
6.5
810-205
205
5.5
9.5
4.0
800-700
700
15.0
6.1
810-250
250
5.9
9.6
5.0
800-800
800
15.2
6.4
810-320
320
6.2
14.1
4.7
800-900
900
15.2
7.6
810-400
400
5.5
13.6
5.6
800-1000
1000
15.3
8.4
810-500
500
6.9
15.8
5.1
810-600
600
5.0
18.0
7.0
810-640
640
8.0
18.0
5.0
810-700
700
5.0
28.0
5.0
810-720
720
7.3
15.2
6.3
810-800
800
8.7
18.5
5.7
810-1000
1000
8.0
20.2
7.0
32 – Tissue Expanders
cm
Tissue Expanders
Tissue Expanders
SMOOTH
SMOOTH
3) Cresent / Smooth / Remote Valve
5) Calf / Smooth / Remote Valve
C
B
A
A
Ref
B
cm
I
C
A
B
C
820-012
12
5.1
2.1
2.1
820-025
25
6
2.7
2.6
820-050
50
6.8
3.5
3.3
I
A
B
C
145
19.2
5.3
2.6
185
22.9
5.7
2.6
Ref
cm
820-100
100
8.1
4.3
3.5
880-145
820-150
150
8.7
4.6
4.1
880-185
820-200
200
9.3
4.9
4.7
820-300
300
10.1
5.6
5.8
820-400
400
11.4
6.2
6.5
820-700
700
13.4
7.8
8.8
6) Ear / Smooth / Remote Valve
C
B
A
Ref
I
33 – Tissue Expanders
A
B
C
841-016
16
6.2
1.6
1.1
841-040
40
6.5
2.2
2.6
841-055
55
7
2.5
3.2
34 – Tissue Expanders
cm
Tissue Expanders
Tissue Expanders
SMOOTH
SMOOTH
7) Spherical / Smooth / Remote Port
8) Elipitical / Smooth / Remote Port
A
Ref
B
cm
35 – Tissue Expanders
I
A
B
C
C
Ref
741-003
03
1.7
741-005
05
2.2
I
741-008
08
2.5
881-010
741-012
12
2.8
741-016
16
3
741-018
18
3.3
741-020
20
3.4
741-030
30
3.8
741-060
60
4.8
cm
10
A
B
C
6.1
2.1
1.8
36 – Tissue Expanders
A
Tissue Expanders
Tissue Expanders
SMOOTH
SMOOTH
9) Ovoid / Smooth / Remote Port
11) Syndactyli / Smooth / Remote Port
B
B
A
Ref
A
cm
I
A
B
861-021
21
2.7
4.2
861-025
25
2.9
4.6
10) Longitudinally Curved / Smooth / Remote Valve
C
A
B
C
851-001
1
1
1
0.3
741-005
2
2
1
0.3
741-008
3
3
1
0.3
741-012
4
4
1
0.3
741-016
5
5
1
0.3
B
Ref
Vol
ml
I
20830-220
37 – Tissue Expanders
cm
I
220
cm
A
B
C
10.0
4.0
4.5
20830-480
480
20.7
5.0
4.8
20830-520
520
16.0
5.0
6.0
38 – Tissue Expanders
A
Ref
Product Catalogue No 6 (October 2008)
Eurosurgical, Merrow Business Park,
Guildford, Surrey, GU4 7WA
T: +44 (0)1483 456007
F: +44 (0)1483 456008
E: [email protected]