Contact Information
Transcription
Contact Information
December Product Round Table Webinar Tuesday, December 16th 2-3pm EST Concall #: 888-324-2904 Passcode: CReichwein All content in this presentation is protected – © 2008 American Power Conversion Corporation Panel of Experts: Robert Bunger Director of Enterprise & Systems Business Development, North America Anthony DeSpirito Vice President- Business Development Brad Binning Cooling Systems Business Development David Derambakhsh Enterprise & Systems Business Development, NAM 3-Phase Power Mark S. Tarantelli 3Phase Business Development - North America Mark Z. Mazur Business Development Manager APC by Schneider Electric – Christine Reichwein – December 16, 2008 A Heritage of leadership, experience and innovation ● APC was acquired by Schneider Electric in 2007 ● MGE UPS Systems, another division of Schneider Electric, merged with APC ● Together they represent the Critical Power & Cooling Services Business Unit of Schneider Electric APC by Schneider Electric – Christine Reichwein – December 16, 2008 APC by Schneider Electric delivers unmatched customer benefits ● Industry’s ● Only most comprehensive integrated product & solutions power, cooling, and management solution ● Industry’s broadest service organization ● Industry’s largest R&D ● The choice of investment IT and Electrical customers and channels APC by Schneider Electric – Christine Reichwein – December 16, 2008 A global offering backed by global teams 2007 figures for Critical Power & Cooling Services Business Unit North America EMEA & LAM 3,000 3,380 $ 40% $ 40% $3.5 billion 2007 revenue Greater China $ 7% 1,970 APC by Schneider Electric – Christine Reichwein – December 16, 2008 Asia-Pacific & Japan $ 14% 6,340 Consolidation by Intel APC by Schneider Electric – Christine Reichwein – December 16, 2008 Data Center Priorities APC by Schneider Electric – Christine Reichwein – December 16, 2008 Customer Challenges ● APC & our partners are well positioned to provide the right solutions for our customer’s current challenges ● Virtualization / Consolidation ● High Density ● High Efficiency ● High Availability ● You will learn about products & solutions that no only meet our customer’s needs in a tough economic environment, but also position them for future growth. APC by Schneider Electric – Christine Reichwein – December 16, 2008 InfraStruXure® Central v5.x An IT-ready, scalable monitoring system which collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network APC by Schneider Electric – Christine Reichwein – December 16, 2008 InfraStruXure Central Applications ● Data Center ● Consolidate viewing & configuration of monitoring appliances Campus Network Manage monitoring appliances across multiple buildings APC by Schneider Electric – Christine Reichwein – December 16, 2008 Remote Offices, Plants, Warehouses Manage a distributed network of monitoring appliances InfraStruXure Central Product Design Benefits Centralized Management Immediate visibility to your physical infrastructure through real-time device monitoring and notification enabling quick assessment of events as they occur. Simplify management of the physical infrastructure using a centralized repository accessible from anywhere on the network through a powerful and easy to use console application Mass Firmware Update Concurrent deployment Multi-vendor Device Support and updates of managed Extensive multi-vendor support for monitoring networked SNMP devices decreases set-up devices. Enable visibility of existing SNMP devices through time and complexity by threshold alert notifications, data trending and reporting simultaneously upgrading firmware for multiple APC devices APC by Schneider Electric – Christine Reichwein – December 16, 2008 Unified Console Customizable Windows and Linux client application enables instant access to InfraStruXure Central application, from anywhere on the network Fault Notification Real-time event notification minimizes response times to critical physical infrastructure events. Enables IT Administrators to reduce mean time to repair, improve efficiency, and maximize uptime. Receive alerts via mobile phones (SMS), Web applications (HTTP Post) & Email InfraStruXure Central v5.x Monitoring & Management Features Alarm AlarmFilters Filters Enables Enablesusers userstotocustomize customize the user interface to the user interface todisplay display devices in a critical, warning devices in a critical, warningoror normal normaldevices devicesstatus status Customizable CustomizableUser UserAccess Access Define Defineuser useraccess accessand andviewing viewing capabilities to individual groups. capabilities to individual groups.Control Control access to devices through administratoraccess to devices through administratordefined defineduser useraccounts. accounts.Additional Additionaluser user access can be managed using the built-in access can be managed using the built-in LDAP LDAPand andActive/Directory Active/Directorysupport support APC by Schneider Electric – Christine Reichwein – December 16, 2008 Custom CustomMapping Mapping Custom Custombackgrounds, backgrounds,user-assignable user-assignable icons, and drag-and-drop icons, and drag-and-dropdevice device placement make it easy to identify placement make it easy to identify problem problemdevices devicesatataaglance glance InfraStruXure Central v5.x Reporting Features Graphical GraphicalTrending TrendingAnalysis Analysis Access Accesscurrent currentand andhistoric historicdata datafor forany any device or group of devices. Plot and device or group of devices. Plot and graph graphmultiple multipledata datapoints pointsininaalogical logical correlation to visualize potential correlation to visualize potential hazardous hazardoustrends trends APC by Schneider Electric – Christine Reichwein – December 16, 2008 Custom CustomReporting Reporting Create, Create,save, save,and andschedule schedulethe thegeneration generationand anddelivery delivery ofofuser-defined reports, making it easier for your user-defined reports, making it easier for yourusers users totoaccess and share information regardless of who access and share information regardless of whothey they are, where they work, and how they want to access are, where they work, and how they want to access information information InfraStruXure Central v5.x Grow with the Business Extendable ExtendableArchitecture Architecture Available Availablenode nodeand andapplication applicationlicense license keys extend the capabilities of keys extend the capabilities ofthe the platform allowing it to grow to meet platform allowing it to grow to meet changing changingbusiness businessneeds needs APC by Schneider Electric – Christine Reichwein – December 16, 2008 Surveillance Surveillance Enhance Enhancevisibility visibilityofofyour yourcritical criticalassets assetswith with physical threat management to monitor and physical threat management to monitor and record recordallallactivity activityininsecured securedareas. areas. AAcentralized centralized repository allows the user to review, search repository allows the user to review, searchand and tag surveillance events for future needs tag surveillance events for future needs InfraStruXure Central v5.x Supports Add-On Software Applications Capacity CapacityManager Manager Planning Planningand andoptimizing optimizingutilization utilizationofofactual actual power, cooling and rack capacities via common power, cooling and rack capacities via common data datacenter centermodel, model,enabling enablingefficient efficientserver server provisioning and right-sizing of your data provisioning and right-sizing of your datacenter center APC by Schneider Electric – Christine Reichwein – December 16, 2008 Change ChangeManager Manager Allows Allowsfor foreasily easilytracking trackingand andexecuting executing moves, adds and changes of IT assets moves, adds and changes of IT assetsininthe the data center via the dynamic data center data center via the dynamic data center model model InfraStruXure Central Platforms ● Enterprise: now scales to 4025 device nodes ● Surveillance: monitors up to 250 camera devices ● Capacity Manager: supports up to 200 racks ● Change Manager: supports up to 8000 IT assets ● Standard: now scales to 2025 device nodes ● Surveillance: monitors up to 125 camera devices ● Capacity Manager: supports up to 100 racks ● Change Manager: supports up to 5000 IT assets ● New Basic: scales to a maximum of 525 device nodes ● Surveillance: monitors up to 15 camera devices ● Capacity Manager: supports up to 20 racks ● Change Manager: supports up to 1000 IT assets APC by Schneider Electric – Christine Reichwein – December 16, 2008 Platform Comparison Max Node Count Price InfraStruXure Central Basic Value InfraStruXure Central Standard Performance InfraStruXure Central Enterprise Up to 525 devices Up to 2,025 devices Up to 4,025 devices ; Fault Tolerant HW Change/Capacity Support Up to 20 racks/1000 assets Up to 100 racks/5000 assets Up to 200 racks/8000 assets Up to 15 cameras Up to 125 cameras Up to 250 cameras Graphing/Trending ; ; ; 3rd Party Monitoring ; ; ; Mass Firmware Updates ; ; ; Directory Service Integration ; ; ; Map View ; ; ; Custom Reporting ; ; ; Alert Notification ; ; ; RMS Support ; ; ; Private Network ; ; ; Surveillance Support APC by Schneider Electric – Christine Reichwein – December 16, 2008 InfraStruXure Central Related Products NetBotz Surveillance Monitor and record all activity in secured areas. Recorded data can be easily reviewed, searched, and tagged for future needs. NetBotz Environmental Detect and alarm on environmental factors which threaten the availability of your network-critical physical infrastructure NetBotz Accessories & Sensors Extend the capabilities of your environmental and security monitoring appliances. APC by Schneider Electric – Christine Reichwein – December 16, 2008 InfraStruXure Central Summary An IT-ready, scalable monitoring system which collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network ● Availability • InfraStruXure Central enables an efficient way for organizations to monitor their company-wide multi-vendor physical infrastructure: power, cooling, security, and environment. Real-time monitoring, user-defined reports and graphs, and instant fault notification and escalation enable quick assessment and resolution of critical infrastructure events that can adversely affect IT system availability. ● Agility • This centralized repository of critical information can be accessed by multiple users from anywhere on the network, creating a consolidated view of the physical infrastructure. • Total Cost of Ownership • The platforms can grow with changing business needs through additional device licenses and add-on surveillance, capacity management and change management modules APC by Schneider Electric – Christine Reichwein – December 16, 2008 InRow RD ® Brad Binning Cooling Systems Business Development All content in this presentation is protected – © 2008 American Power Conversion Corporation Agenda ● Nomenclature ● Identify the opportunities that APC has for incremental growth with the InRow RD ● RD Applications ● Features and Benefits ● Identify an opportunity and act on it using APC’s available sales tools APC by Schneider Electric – Christine Reichwein – December 16, 2008 InRow RD New Nomenclature ACRD100/ 200 Model # Cooling Coil Type Heat Rejection Equipment Nominal Capacity Nominal Width ACRD100 DX Air-Cooled Condenser 10kW 12 in (300 mm) ACRD200 DX Fluid Cooler 10kW 12 in (300 mm) ACRD500 (DX RP without humidifier) DX Air-Cooled Condenser 29kW 24 in (600 mm) ACRC100 Chilled Water Chiller 18kW 12 in (300 mm) ACRC500 Chilled Water (CW RP without humidifier) Chiller 43kW 24 in (600 mm) ACRD500 APC by Schneider Electric – Christine Reichwein – December 16, 2008 Market Opportunity Data is doubling every 18 months… APC by Schneider Electric – Christine Reichwein – December 16, 2008 Corporations faced with conflicting goal—WW SMB IT spend outpaces Corp… InRow RD Applications ● Used in Closets, Server Rooms, and Data Centers ● Retrofit of existing spaces ● New construction ● High-Rise Buildings ● Spaces with no cooling to address growing heat densities ● Supplemental cooling to overload comfort system APC by Schneider Electric – Christine Reichwein – December 16, 2008 InRow RD 300mm – Two Versions ●Air-Cooled – ACRD 1xx ● Requires a remote air-cooled condenser ● Easy to deploy—does not require pump sizing ● Distance between the cooling unit and condenser is limited • Roughly 200 equivalent linear feet ● Least cost option ● One condenser required for each RD APC by Schneider Electric – Christine Reichwein – December 16, 2008 Air-Cooled Condenser (ACRD100 and ACRD500) InRow RD 300mm – Two Versions ●Fluid-Cooled - ACRD 2xx ● Complete system requires pump package and fluid cooler or cooling tower ● Can leverage existing condenser/glycol loops that have available capacity ● No limitations on placement of fluid cooler/water tower ● Requires pump ● Can have multiple RD200 on single cooling tower or fluid cooler APC by Schneider Electric – Christine Reichwein – December 16, 2008 Fluid Cooler (Usually Glycol/Water Mixture) (ACRD200) Available SKUs ● Available SKUs: ● ACRD100 ● ACRD101 ● ACRD200 ● ACRD201 SKU Heat Rejection Type Voltage Frequency ACRD100 Air-Cooled DX 208V, 1-Phase 60 Hz ACRD101 Air-Cooled DX 230V, 1-Phase 50 Hz ACRD200 Fluid-Cooled DX 208V, 1-Phase 60 Hz ACRD201 Fluid-Cooled DX 230V, 1-Phase 50 Hz APC by Schneider Electric – Christine Reichwein – December 16, 2008 Air-Cooled Product Design Benefits RD100 Isolation Ball Valve Assembly Retractable Electronics Module Allows unit to be easily disconnected from piping for service or removal Easy access to electronics module Cooling Coil Cu tube, Al fin Top or Bottom Piping Connections Hot Gas Bypass Flexible connection options Allows for low load handling capabilities Replaceable Air Filters Filters air and prevents air debris from entering unit Variable Speed Fans Reduce energy consumption during off-peak hours; Hot swappable Condensate Pump Dual Condensate pumps for condensate management Casters Easily moved APC by Schneider Electric – Christine Reichwein – December 16, 2008 Compressor Scroll Fluid-Cooled Product Design Benefits RD200 Variable Speed Fans Top or Bottom Piping Connections Reduce energy consumption during off-peak hours; Hot Swappable Flexible connection options Retractable Electronics Module Cooling Coil Easy access to electronics module Cu tube, Al fin Condensate Pump Hot Gas Bypass Dual Condensate pumps for condensate management Allows for low load handling capabilities Brazed Plate Heat Exchanger Promotes heat transfer while isolating media Compressor Scroll Casters APC by Schneider Electric – Christine Reichwein – December 16, 2008 Variable Fan Speed Assembly ● Features Include: ● Fan speed adjusted from 30 to 100% for improved control and energy savings during off peak conditions ● Tubeaxial direct drive motors ● Hot-swappable plug connections •Ensures low time to repair ● High-Reliability fans with integrated EC motors ● 6 Fans for 2200 CFM total ● Fans soft-start to minimize inrush APC by Schneider Electric – Christine Reichwein – December 16, 2008 Value—Active Response Controls ● Built into the Microprocessor Controller ● Maintains Rack Inlet Temperature 7 x 24 ● Provides Visibility into the Units Operation, Health, and Capacity ● Easily Plan for Future IT Deployments ● Allows for Rapid Response to Failures ● Modes of Operation ● InRow ● Containment ● Spot Cooling (300 mm Only) APC by Schneider Electric – Christine Reichwein – December 16, 2008 Value—Thermal Containment ● Increases Cooling Capacity ● Minimizes Units Required to Active Redundancy ● Eliminates Hot Air Mixing Hot Aisle Containment System (HACS) ● Improves Cooling Predictability Rack Air Containment System (RACS) APC by Schneider Electric – Christine Reichwein – December 16, 2008 User Interface Design Benefits Common Interface —common across APC products for intuitive operation Available Data —Air conditions, alarm set points, alarm conditions, current mode of operation, system log Control Functions —Cool set points, alarm set points, custom input/output contacts, definitions System ON Status Light Check Log LED Warning Status Light Critical Status Light APC by Schneider Electric – Christine Reichwein – December 16, 2008 4 Line Alphanumeric Display Feature Summary InRow Air Conditioning for Wiring Closets, Server Rooms, and Data Centers ● Availability ● Rack Inlet Control ● Active Response Controls ● Total Cost of Ownership ● Variable Speed Fans ● InRow Architecture ● Agility ● Modular Design ● Flexible Deployment ● Manageability The Predictable Solution for an Unpredictable Environment APC by Schneider Electric – Christine Reichwein – December 16, 2008 ● InfraStruXure Central ● BMS Integration - Modbus Solving Customer Issues “I want something that is portable.” “My legacy units have worked just fine, what benefit will I get from ripping them out?” “Will I have any problems with water in my closet or data center?” “My current loads are not very high. I do not need such a large A/C. Will this unit be too large for me?” “I would like to use my building condenser water.” APC by Schneider Electric – Christine Reichwein – December 16, 2008 Configuring Correct Solutions ● Air-Cooled DX Unit ● What is the ambient (outside) temperature? ● Where is the data center located in relation to an outside wall? ● What is the Density per Rack? ● What is the Delta T or airflow of the IT equipment in the racks? ● How Many Racks? ● To What Temperature do they want to Control their Data Center? ● ASHRAE TC 9.9 (68 to 77 F) APC by Schneider Electric – Christine Reichwein – December 16, 2008 Sales Tools ● Data Center University (DCU) Modules ● InRow RD Product Overview ● How to Sell InRow RD (targeted towards the partner community) ● Installation considerations for the InRow RD (targeted towards the end user and/or partner) ● Sales Tools Portal ● Presentations • Family Overview • How to Sell • Technical Presentation ● FAQ ● Guide Specifications ● App Notes ● Competitor Comparisons ● BADM ● www.apc.com ● Product Slick ● User Manuals APC by Schneider Electric – Christine Reichwein – December 16, 2008 Summary Row-based, direct expansion cooling solutions for the closet, server room & small data center ● Modular Design Increases AGILITY by providing scalable solutions to add cooling as demand increases ● Improved Energy Efficiency and Rightsizing reduces TOTAL COST OF OWNERSHIP ● Placing the unit in the row of racks moves the source of cooling closer to the heat load and minimizes air mixing, thus improving AVAILABILITY The predictable solution for an unpredictable environment APC by Schneider Electric – Christine Reichwein – December 16, 2008 Partner Presentation General Purpose UPS offerings MGE Products David Derambakhsh Business Development Manager , 3-Phase UPS All content in this presentation is protected – © 2008 American Power Conversion Corporation Product Segments ● 3-Phase UPS Segmentation ● Modular/IT Feature ● Versatile/General Purpose APC by Schneider Electric – Christine Reichwein – December 16, 2008 Modular ● Modular 3-Phase UPS Data Center Solutions ● Integrated UPS and Power Distribution ● IT Rack Aesthetics ● IT Management Systems Integration ● Higher Performance ● Infrastructure Solutions ●Smart-UPS VR (20kVA to 30kVA) ●Symmetra PX (20kW to 500kW) ●Symmetra MW (400kW to 1600kW) APC by Schneider Electric – Christine Reichwein – December 16, 2008 Integrated Data Center Applications Versatile UPS (Ex-MGE products) ● Versatile / General purpose 3-Phase UPS Segmentation ● Traditional “box type” UPS ● Hardwire Input and Output ● Installation in Electrical and Equipment Room, Service Corridor, Basements, Data Center White Space ● Building Management System Integration ● IT Management Integration Data Center and Industrial Application s APC by Schneider Electric – Christine Reichwein – December 16, 2008 Portfolio from 10kVA to 1600kVA Symmetra LX Symmetra PX Symmetra MW The broadest UPS portfolio in the industry with solutions from the wiring closet to the data center to the factory floor. Smart-UPS Smart-UPS VT APC by Schneider Electric – Christine Reichwein – December 16, 2008 MGE Galaxy MGE EPS Some Versatile/General Purpose Products Galaxy 4000 Galaxy PW Power Distribution VT / AIS series APC by Schneider Electric – Christine Reichwein – December 16, 2008 Power Distribution From UPS to Racks UPS PMM APC by Schneider Electric – Christine Reichwein – December 16, 2008 RPMM RPMM IT RACKS Sales Strategy ● Versatile / General purpose 3-Phase Solutions ● Smart-UPS VT/AIS 3000 (10kVA to 30kVA) • Compact, 3-Phase power protection • Scalable Runtime • Small Data Centers • AIS 3000 has NEMA rated enclosure, industrial site drip protection, and air filtration ● MGE Galaxy(10kVA to 225kVA) Including Galaxy 5000 • 3-Phase power protection for small to large facilities and equipment rooms Applications from Factory Floors to Data Centers • Galaxy 3000/4000, Galaxy 5000, Galaxy PW ● MGE EPS (300kVA to 1100kVA) • 3-Phase power protection for small to large facility/equipment rooms APC by Schneider Electric – Christine Reichwein – December 16, 2008 Applications/Environments • Data Servers • Communications Servers • Storage Devices • Active Network Devices • Airports • Railroads • Public Transportation • Medical Applications • High Reliability • Parallel-Ready • Communication Options • Power Quality Design • Robust Design • Redundant Components Example Customers Applications Infrastructures/ Processes Relevant Features Data Centers/ Computer Rooms APC by Schneider Electric – Christine Reichwein – December 16, 2008 Telecommunications • Phone Networks • Mobile Phone Networks • Internet Centers • Radio/Television • Expandable • Extended Battery Runtimes • Full Line of Communication MGE Advantages- Flexibility ● Versatile UPS vs. Competition ● Excellent Efficiency at Low Loads •Change in efficiency is typically < 2% from 100% to ~30% load ● Low UPS-to-Generator Sizing Ratio •Due to low THD and High Low Generator Cost •Lower Cable Cost ● Lower Installation Costs •Low THD •High Input Power Factor ● 100% Continuous Duty Static Switch •Requires no mechanical contactor/breaker •Instantaneous Response Time ● Excellent Transient Response •UPS regulates the output voltage no matter how fast and drastic the load changes APC by Schneider Electric – Christine Reichwein – December 16, 2008 Symmetra PX 250/500 Modular Power Distribution Mark Tarantelli Business Development Manager - North America 3PH Modular Power Systems All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra® PX 250/500kW ● White space or backroom install ● Double conversion online topology ● 96% efficiency – highest in its class ● Input PF regulated to unity ● 400 or 480VAC input/output ● 1.0 output PF (kW=kVA) ● Dual mains ● Internal bypass static switch ● On-the-fly/ off-line firmware upgrades ● Event logging w/ graphs ● Regulated fan speed (reduces noise) ● Extended life batteries (5 – 7 yrs) ● Predictive maintenance ● Waveforms graphically displayed Key Features Redundant, Scalable, High Availability Power Protection APC by Schneider Electric – Christine Reichwein – December 16, 2008 Symmetra® PX 250/500kW 500kW frames populated at lower capacity enables one-time installation service Scalable, Expandable Scalable from 25kW to 500kW Parallel 4 systems to 2MW in (2009) Bus bar connected cabinets Identical form-factor static switch DC Disconnects at each battery frame Additional battery frames scale runtime N+X configurations Hot swap power modules Hot plug SSW Combined maintenance bypass and sub-feed distribution panels All components conform to ISX formfactor (2000mmx1070mm HxD) 250kW = 10.1 ft row length 500kW = 17.01 ft row length APC by Schneider Electric – Christine Reichwein – December 16, 2008 500kW of High-Efficiency 475kW 450kW 425kW 400kW 375kW 350kW 325kW 300kW 275kW 250kW 225kW 200kW 175kW 150kW 125kW 100kW 75kW 50kW 25kW Scalable Power Protection APC by Schneider Electric – Christine Reichwein – December 16, 2008 Symmetra® PX 250/500kW Configuration Flexibility ● Modular architecture - numerous configurations ● ● ● ● ● White Space, Back Room, Wall Space With or without MBwD Line up Batteries, Remote Batteries Top Feed, Bottom feed Single Feed, Dual Feed ● 250kW Frame ● Populated with 1-10 PMs ● 2 or more battery frames with load dependant module population • 5 - 45 minute runtime ● 500kW expansion ● ● ● ● One additional power frame 500 kVA SSW Additional power modules 4-8 battery frames with load dependant module population • 6 - 19 minute runtime APC by Schneider Electric – Christine Reichwein – December 16, 2008 Symmetra® PX 250/500kW Building Blocks MBwD UPS I/O base Frame UPS PM Frame Q5 Battery Frame PM 25kVA, 4u Battery shelf PM 25kVA, 4u Battery shelf PM 25kVA, 4u Battery shelf PM 25kVA, 4u Battery shelf Battery Sidecar Bottom Feed Frame Intercon. Intercon. Sidecar for remote batteries Used for bottom feed cabling 300mm (1/2 rack) 300mm (1/2 rack) Display PM 25kVA, 4u 250kVA SSW, 15u (Possible to replace with 500kVA SSW) 600mm (SX rack) Depth and height is new APC standard (2000mm height, 1070mm depth). APC by Schneider Electric – Christine Reichwein – December 16, 2008 Interconnections PSU Interconnections System IO (PSU, IM, etc.), 5u ABB Interconnections Isom ax S5 3pol 400mm (new) AC Input MCCB & relay plug and play unit Q1 ABB Isomax S5 3pol MCCB & relay plug and play unit PM 25kVA, 4u PM 25kVA, 4u Battery shelf PM 25kVA, 4u Battery shelf PM 25kVA, 4u Battery shelf PM 25kVA, 4u Battery shelf 600mm (SX rack) BMB BMB Field Wiring Q2 & Q3 750mm (wide SX rack) Symmetra® PX 250/500kW Sub-feed breaker monitoring, compatibility, and sizing ● MBwD and sub-feed monitoring ● Q2, Q3, & Q5 status ● Sub-feed branch circuits • Current, status, and Bypass voltage ● 800A Breakers ● AC Output (Q2) ● Maintenance Bypass (Q3) ● Bypass Input (Q5) ● ABB only APC by Schneider Electric – Christine Reichwein – December 16, 2008 500kW of High-Efficiency 475kW 450kW 425kW 400kW 375kW 350kW 325kW 300kW 275kW 250kW 225kW 200kW 175kW 150kW 125kW 100kW 75kW 50kW 25kW Scalable Power Protection APC by Schneider Electric – Christine Reichwein – December 16, 2008 What is Modular Power Distribution? Hot Swappable Standardized Modules Containing Circuit Breakers, Branch Current Monitoring (BCM) and an Output Whip (Cord set) to feed IT Racks. APC by Schneider Electric – Christine Reichwein – December 16, 2008 What is Modular Power Distribution? ● Modular Power Distribution is a combination of Power Distribution Modules (PDMs) and Modular Power Distribution Units, known as either a PDPM or PDUM. ● The Power Distribution Modules consists of an industry standard circuit breaker, branch current monitoring (BCM), output cable and connector plug combined into a hot-swappable module that feeds power to IT racks. ● The Modular PDU is the source of amperage for the rest of the distribution, housing the hot-pluggable power backplane, the main circuit monitoring bus, and the support structure for the PDMs. ● Each Modular PDU shares the same basic design which enables simple plugand-play for any Distribution Modules into any Modular Power Panel of common voltage. APC by Schneider Electric – Christine Reichwein – December 16, 2008 Advantages ● Repeatable Design ● Most flexible power distribution concept in the market. ● Allows higher power densities in distribution products. ● Auto sensing of breaker size and location can be done to better automate BCM set up ● Supports 400V Distribution in NAM ● Safe and speedy Installation ● Disruptive innovation allowing for hot swap-ability without downtime, hot work or highly skilled electricians. ● Empowers Users. ● No need to predict future rack power requirements. ● Similar costing to current distribution methods. APC by Schneider Electric – Christine Reichwein – December 16, 2008 ½ Rack PDU High Density Design – 266kW in ½ rack Power/Floor-space increase - Current offer is more than 2X the floor space with ~half the density Electrical Efficiency - Using autotransformer technology, 10X the efficiency of standard transformers Reduced Procurement costs - Higher voltage distribution means thinner cord sets to the rack, at today's skyrocketing copper cost - means big savings upfront Reduced Lifecycle costs - ease of use and much quicker Moves/Adds/Changes saves installation costs Reduced data center complexity - User configurable distribution, pre- and post-sale Safely expand and service without forced shutdowns APC by Schneider Electric – Christine Reichwein – December 16, 2008 The Product Line Distribution Modules ½ Rack Power Distribution Unit (PDU) ½ Rack Remote Power Panel (RPP) 415V - Dec 2008 480V:415V •288kW 400A •72 Poles •24 Modules •20A (415V) •20A, 50A/60A (208V) •Circuit monitoring included •Breaker position monitoring 5U Rack-mount Distribution Panel (RDP) •72 kW 200A •18 Poles •6 Modules APC by Schneider Electric – Christine Reichwein – December 16, 2008 208V - Mar 2009 •144 kW 400A •72 Poles •24 Modules Distribution Modules Single and Three Phase Options 20A Module with IEC 309 connector or 3 240V 1PH IEC connectors Optional Calamari Plug IEC309:3 C-19 splitter Multiple cable lengths & extenders Latch and Unlatch Mechanism for easy hotpluggable insertion/removal Includes Branch Circuit Monitoring Breaker Position Monitoring Quick status Info LEDs APC by Schneider Electric – Christine Reichwein – December 16, 2008 Rack Systems Presented by: Mark Mazur NAM Business Development Manager For: Rack Systems Rack PDU’s Small System Cooling All content in this presentation is protected – © 2008 American Power Conversion Corporation NetShelter® SX Available NOW!!! Enclosures providing cooling, power distribution, cable management, and environmental monitoring for applications in IT environments New!!! 42U x 600mm x 1200mm DEEP 48U x 750mm x 1200mm DEEP 48U x 600mm x 1200mm DEEP 42U x 750mm x 1200mm DEEP World’s most versatile rack enclosure for demanding IT environments APC by Schneider Electric – Christine Reichwein – December 16, 2008 NetShelter® SX Available NOW!!! Enclosures providing cooling, power distribution, cable management, and environmental monitoring for applications in IT environments New!!! New!!! 24U x 600mm x 1070mm DEEP World’s most versatile rack enclosure for demanding IT environments APC by Schneider Electric – Christine Reichwein – December 16, 2008 Vertical Cable Organizer New!!! Perfect for Switch Applications Holds up to 375 Cat-5 Cables Optional Covers Available APC by Schneider Electric – Christine Reichwein – December 16, 2008 Horizontal Cable Management New!!! 2U Horizontal Cable Organizer with Cover AR8600 1U Horizontal Cable Organizer With Cover AR8602 APC by Schneider Electric – Christine Reichwein – December 16, 2008 2U Horizontal Cable Organizer Double Sided with Cover AR8601 Vertical & Horizontal Cable Organizers APC by Schneider Electric – Christine Reichwein – December 16, 2008 Switch Application New Vertical Cable Organizers, qty 2, with Optional Covers Installed in a NetShelter SX Wide Rack. New!!! New Horizontal Cable Organizers with Integral Covers Installed Above and Below a Cisco 6509. New!!! APC by Schneider Electric – Christine Reichwein – December 16, 2008 High Density Metered Rack PDU AP7866 Metered rack power distribution unit solves racklevel power needs in a space efficient Zero-U form factor for high density applications. New! • 60A 3-phase IEC320 input connector; 21.6kW input derated to 16.2kW for continuous operation • Six (20A) magnetic-hydraulic circuit breaker protected outlet banks • Industry leading 0U low profile design allows access to hot swap blade components; first unit with max depth < 3” Blade Application: AP7866 installed in a 600mm wide NetShelter® SX enclosure • Comprehensive overload monitoring including current metering on each phase and on each of six load banks • Network Management: Access, configure and manage units from remote locations via web, SNMP and telnet • Flexible outlet configuration; (12) C19 receptacles for high density equipment and (3) C13s for ancillary equipment • High temperature design for operation up to 60ºC User interface allows full user customization of alarms APC by Schneider Electric – Christine Reichwein – December 16, 2008 High Density Metered Rack PDU AP7866 16.2kW Metered Rack PDU, 208V 3 Phase 60 Amp Input, (12) IEC 320 C19 & (3) IEC 320 C13 Outlet Plugs New! Low profile breaker box provides clearance of HP C7000 rear modules APC by Schneider Electric – Christine Reichwein – December 16, 2008 Available NOW!!! 90 deg power cords provide clearance of HP C7000 rear modules Questions? APC by Schneider Electric – Christine Reichwein – December 16, 2008 We Want to Hear From You! Channel Programs: [email protected] Christine Reichwein: Program Operations [email protected] All content in this presentation is protected – © 2008 American Power Conversion Corporation