Metromont CEFPI 3.29.11 (NXPowerLite).ppt [Compatibility Mode]
Transcription
Metromont CEFPI 3.29.11 (NXPowerLite).ppt [Compatibility Mode]
Energy Analysis of School Projects 2011 Southeast Region Conference Savannah, Georgia March 29, 2011 Presented by Terry Gladden, RA George Spence Angela San Martin P.E., LEED® AP AIA/CES Program Purpose Program Title: Energy Analysis of School Projects Program # Provider # Provider Name: Learning Units: SE 15-11 F118 CEFPI 1.0 HSW “Conference of Educational Facility Planners International” (CEFPI) is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will be reported to CES Records for AIA members. Certificates of Completion for non-AIA non members are available on request. This program is registered with the AIA/CES for continuing professional education. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA of any material of construction or any method or manner of handling, using, distributing, or dealing in any material or product. Questions related to specific materials, methods, and services will be addressed at the conclusion of this presentation. Learning The BasicsObjectives of Precast/Prestressed Concrete 1. Understand how owner/design team can increase building envelope thermal efficiency to achieve advanced energy design in K -12 schools 2. Explain methods available to audit and reduce energy costs by use of case studies 3. Explore how to design high performance exterior wall systems with continuous insulation and thermal mass 4. Understand the concepts of sustainability in K -12 schools and how to lower life cycle energy costs Largest School System in Georgia Gwinnett County Public School System is the largest in Georgia with a student population of 160,000 housed in 115 K-12 facilities. Largest School System in Georgia Standard sizes (student capacity) of facilities in Gwinnett County are as follows: Elementary Schools: 1100 Middle Schools: 1800 High Schools: 3000 Energy Audit Suggestions Standard HVAC System : Water source heat pump system that utilizes a separate heat pump for each classroom or major space in the building. Outside air is introduced through conventional Energy Recovery Units. Air quality is accomplished through the use of bi-polar polar ionization devices. Energy Audit Suggestions The system is controlled by a computer driven energy management system, which controls both temperature and humidity, and keeps the units turned off when not needed. Energy Audit Suggestions Gwinnett Schools makes use of T-8 8 light fixtures with electronic ballast, LED exit lights and occupancy sensors that turn off the lights and the HVAC when a room is unoccupied. Energy Audit Suggestions Energy Audit Suggestions Energy Audit Suggestions •Change Change all HVAC filters 6 times per year. •Monitor Monitor and maintain the optimum chemical levels in cooling towers and loops to prevent corrosion and bacterial contamination •Regular Regular cleaning of the coils in the WSHP’s and refrigeration equipment. •Scheduled Scheduled PM on all equipment as recommended by manufacturer. Energy Audit Suggestions Gwinnett County Public School System’s standard practice is to design and build multi-story multi buildings in compact designs, thus minimizing roof area and exterior wall area. Gwinnett School of Mathematics, Science and Technology Energy Audit Results KBtu/Sq. Ft./ year Elementary Schools : Middle Schools: High Schools: 2009 38 41 44 Twin Rivers Middle School 2010 35 36 40 % lower 8% 12% 9% Energy Audit Results Twin Rivers Middle School floor plan (3 level classroom wing on right) Energy Audit Results Case Study of Four Gwinnett Middle Schools S.F. Twin Rivers MS North Gwinnett MS Lanier MS Trickum MS 231,728 241,350 241,350 241,350 Students 1,422 1,793 1,154 1,359 Energy Audit Results Gwinnett Middle School Energy Use Comparisons Year Ending 12/2010 40 kBtu/s.f. kBtu/s.f. 50 Twin Rivers North Gwinnett Lanier Trickum 30 20 25 Middle Schools Energy Audit Results Annual Energy Use For Four Gwinnett Middle Schools Total Energy kBtu/SF Twin Rivers MS North Gwinnett MS Lanier MS Trickum MS Average MS Highest using MS 27.0 31.5 32.0 32.5 33.0 48.0 % above Twin Rivers 17% 18% 20% 33% 78% Total Precast Schools Why Precast? § Energy Efficient Results § Virtually eliminates mold & mildew § Low maintenance Benefits of Total Precast School Building Systems § Speed of construction § Proven and cost effective § Architectural finish options § Built-in structural integrity § Fireproof structure § Plant manufactured reliability Construction of Total Precast Schools Middle School Twin Rivers Middle School Gwinnett County Public Schools Gwinnett County Public GA Schools, Buford, Buford, GA 231,728 s.f. Erected in Three Months Three Story Classroom Wing Total Precast Schools Twin Rivers Middle School Viewspace acrossduring 4 classrooms Open, clear construction Bid Price: $23,180,000 $100/sf project 10%-15% less than brick & block method Demising Walls are concrete block for flexibility Same area with walls and finishes Total Precast Schools Main Hallway View across 4 classrooms Demising Walls are concrete block for flexibility Twin Rivers Middle School Total Precast Schools Media Center Demising Walls are concrete block for flexibility Twin Rivers Middle School Up Front MEP Coordination is Critical MEP Installation, suspended from Double Tees Speed of Completion Twin Rivers Middle School turned over eighteen months after notice to proceed Finished six months ahead of Mountain View High School next door, started at same time. Cunningham Forehand Matthews & Moore Architects Building with limited site lay-down lay area and access March 3, 2009 Gwinnett County Public Schools Buford, GA May 29, 2009 210,000 s.f. erected in 52 Work Days Adjacent to Occupied Classrooms Panelization of load-bearing bearing walls Classroom Wings: load bearing thermal efficient wall panels with punched openings Panelization of load-bearing bearing walls Classroom Wing: § Exterior load bearing thermal efficient wall panels with punched openings § One piece: ~12'-0" x 45'-0" § Supports double tee floor and roof system § Area under roof: ~19,200 SF § Time to erect precast envelope: ~8 days Building section Classroom Corridor Classroom Section – Typical Two-wide Two Classroom Wing Walls and one line column & beams with two spans of double tees. (Non-precast precast corridor walls are CMU or metal studs & sheet rock.) Detailing Thermal Efficient Wall Panels Definition of Continuous Insulation (c.i.) ASHRAE 90.1 – 2007 ACI per Design Award Winner Continuous Insulation around perimeter of building. Concrete Wall Panel nearly perfect “ci” “Insulation that is continuous across all structural members without thermal bridges other than fasteners and service openings.” Detailing Thermal Efficient Wall Panels ACI Design Award Winner No Solid Zones – (C.I.) Solid Zones Solid zones reduces R-Value Value by as much as 50% Detailing Thermal Efficient Wall Panels Window/Door Head and Sill No Solid Zones – (c.i.) Use wood blocking or necked-down necked insulation Detailing Thermal Efficient Wall Panels Corner Detail with c.i. Return insulation at corner conditions to continue c.i. Detailing Thermal Efficient Wall Panels ACI Design Award Winner Foam Wall Panel at Roof Insulation (c.i.) Return insulation through interior concrete wythe to meet roof insulation for c.i. Detailing Thermal Efficient Wall Panels ACI Design Award Winner § Foam joint to equal wall R-value R Foam § Backer rod § Sealant Corner Detail with c.i. Install insulation at wall panel joints prior to caulking. R-Value Value of joint treatment should equal that of the wall. High Performance Thermal Efficient Wall Insulated Wall Panels Thickness 6” to 14” max. R-Value R-4 to R-35, typically R-12 Mass Walls Non-Residential Insulation min. R-5.7ci Continuous insulation side-to-side, top-to-bottom. 12' 12'-0" or 13'-4" Insulation Carbon Fiber Wythe Connector Exterior 2" Varies 2" w/o Reveals 2 ½" with Reveals Concrete Pilaster (coincides with haunch for DT) Steel Mesh Interior Section - High Performance, Fully Composite Precast Wall System High Performance Thermal Efficient Wall Panels Benefits of carbon grid trusses: § Continuous insulation to all edges of the panel § No thermal bridging § Non-corrosive § Strong - over 6 times the tensile strength of steel reinforcing High Performance Insulation System Total Precast Building System Designing Precast Wall Systems §Load bearing and non-load load bearing §Insulated R-4 to R-35 §Fire Rated – no on-site site fireproofing §Sound Isolation (8" wall = 58 STC) §Interior paint ready surfaces §Electrical conduit and boxes cast in Architectural Finishes & Brick Veneer § § § Reveals Thin Brick Form liner § § § Sandblast Retarded Aggregate Dimensional Stone Brick Patterns and Mortar Joints Running Bond Racked Joints Flemish Bond Stack Bond Concave Joints Common Bond Traditional Brick Face Dimensions § Modular Brick Coursing: § 2 ¼" H x 7? " L with ? " joint § Vertical coursing: 3C = 8 inches § To reduce costs: § Eliminate corner brick at jambs, head § § and sill Minimize cut brick Design the elevation down to half brick Designing Precast Wall Systems with Brick Manufacturing Process § Install brick formliner § Place bricks § Set reinforcement § Place concrete and insulation as required Cast-in Thin Brick Veneer Total Precast Building System Cast-In In Brick: Manufacturing Cast- In Brick Mfg. Process 1. Clean form, layout exterior facade 2. Place brick, reveals, openings, etc. 3. Rebar and prestressing strand is placed 4. Concrete for outer wythe is placed 5. Insulation is set 6. Concrete for inside wythe is placed 7. Cure, remove, clean & store for shipping Min. 5,000 psi concrete in-lieu of 750 to 1200 psi mortar, water migration through the exterior wythe is not an issue Designing Precast Wall Systems with Brick Cast-in Thin Brick § Actual clay masonry products are cast directly into the concrete panels: § Min. 5,000 psi concrete vs. 750 psi to 2,500 psi mortar § Superior durability § Ease of maintenance § Design flexibility § Low moisture absorption <5% Cast-in Thin Brick Veneer Total Precast Building System Designing Precast Wall Systems with Brick Cleaning, Storage and Delivery Preparation § Pressure wash panels § Store at manufacturing plant § Load day before installation § “Just In Time" delivery Speed of Installation – 28' tall wall comparison § Precast 4,032 SF installed in one day § Brick & Block Cavity Wall 400 SF installed in one day Cast-in Thin Brick Veneer Total Precast Building System Precast Wall System vs. Cavity Wall System Limitations of mortar set brick: § Building codes severely limit use due to wind and seismic loads §Significant Significant maintenance problems §Water penetration is problem Precast Wall System vs. Cavity Wall System Precast Walls § Manufactured in controlled environment § Precast is impervious to water & air § No voids or cavities § Less opportunities for mold and mildew: no food source, moisture or interior cavity Brick & Block Cavity Walls § Designed as a "wet wall" system § Mortar joint – 750 to 2,500 psi § Typical field installation includes: concrete block, waterproofing, insulation, lintels, masonry ties, weep holes and brick § Weep holes must stay clear during construction to properly remove moisture Brick Veneer Interior concrete wythe - with paint ready surface Concrete Insulation Precast Wall Detail Concrete block – interior wall surface Brick Veneer Mortar Joint Insulation Air Space Cavity Wall Detail Precast Wall System vs. Cavity Wall System Concrete block – interior wall surface Brick Veneer Brick Veneer Concrete Insulation Interior concrete Wythe - with paint ready surface Precast Wall Detail Mortar Joint Insulation Air Space Cavity Wall Detail Joint Comparison – 30' high x 200' long wall with no openings § Precast wall system with brick § 480 LF of panel to panel joints (sealant) § Cavity wall with brick veneer § 36,308 LF of mortar joints § 120 LF of control joints Note: The smaller footprint of the precast wall can contribute to a decrease in the gross SF of the building footprint Sustainability of Precast Concrete Sustainability: Hepatica 3/6/10 Sustainability of Precast Concrete Sustainability: Our capacity to endure. The Pantheon Sustainability of Precast Concrete Sustainability – our capacity to endure. During Construction: § Local materials, recycled steel, fly ash § No jobsite waste, no site disturbance § Low embodied energy Sustainability of Precast Concrete Sustainability – our capacity to endure. During Construction: § Local materials, recycled steel, fly ash, § No jobsite waste, no site disturbance § Low embodied energy Henceforth: § Reduced energy for heating & cooling § Fire proof, storm proof structure Sustainability of Precast Concrete Sustainability – our capacity to endure. During Construction: § Local materials, recycled steel, fly ash, § No jobsite waste, no site disturbance § Low embodied energy Henceforth: § Reduced energy for heating & cooling § Fire proof, storm proof structure § Low maintenance Sustainability of Precast Concrete Sustainability – our capacity to endure. During Construction: § Local materials, recycled steel, fly ash, § No jobsite waste, no site disturbance § Low embodied energy Henceforth: § Reduced energy for heating & cooling § Fire proof, storm proof structure § Low maintenance § Recyclable Sustainability of Precast Concrete Sustainability – our capacity to endure. Research studies reveal: § Energy to operate building is 9-to to-1 over energy to construct building § The most cost-efficient green buildings are those that are supersuper insulated § Focus on eliminating thermal “bridging” between the interior and exterior pays High Performance Thermal Efficient Wall Panel üInsulation from edge-to-edge edge and top-totop bottom üThermal Mass üLoad Bearing üImpervious to water penetration üAir barrier üEffective vapor barrier High Performance Thermal Efficient Wall Panels § Minimum R-values are determined by ASHRAE 90.1 energy code § Advanced Energy Design per ASHRAE 189.1 requires exceeding 90.1 by 30% § Basis for LEED points ASHRAE 90.1 8 Climate Zones for USA High Performance Thermal Efficient Mass Walls High Performance Thermal Efficient Wall Panels R- 7.6 “ci” for mass walls High Performance Thermal Efficient Wall Panels Advanced Energy Design, ASHRAE 189.1 Climate Zone 90.1 Advanced Zone 2 5.7 7.6 Zone 3 7.6 9.5 Zone 4 9.5 11.4 High Performance Thermal Efficient Mass Walls Net-Zero-Energy Energy Building Thermal Mass Research study shows 16% savings for precast clad c.i.p. frame building vs. steel frame/metal stud wall is Climate Zone 3 High Performance Thermal Efficient Mass Walls Time Lag Damping Thermal mass § Delays the peak heating/cooling loads § Reduces peak energy requirement § Smaller investment in HVAC equipment Water Vapor Transmission Outside Inside 2” Concrete 4” EPS Temperature differential, relative humidity and the “permeance” profile, can be used to calculate dew point in the wall. .68 .20 16.0 .20 .25 Component R-Values Actual Temperature Dew Point Temperature Water Vapor Transmission Season: Winter 70 oF Inside 30% RH 30 oF Outside 50% RH Material Properties: Concrete R 0.08/in, 3.2 perm-in EPS R 4.00/in, 2.0 perm-in Actual Temp. 80 Dew Point Temp 20 10 Exterior Air Film 30 2" Concrete 40 4" 4”XPS EPS 50 2" Concrete Temperature (F) 60 Interior Air Film 70 0 No Condensation Potential Water Vapor Transmission Season: Summer 70 oF Inside 30% RH 90 oF Outside 80% RH Material Properties: Concrete R 0.08/in, 3.2 perm-in EPS R 4.00/in, 2.0 perm-in Actual Temp. 100 Dew Point Temp 90 30 20 10 Exterior Air Film 40 2" Concrete 50 4"EPS XPS 4” 60 2" Concrete 70 Interior Air Film Temperature (F) 80 0 No Condensation Potential Water Vapor Transmission If dew point occurs in wall, add vapor barrier § The proper location of vapor barriers: § In cold climates, located to the warm inside surface. § In hot /humid climates, to the warm outside surface. § In temperate climates, perhaps omitted. Thermal Imaging Survey Results Atlantic Southeast Infrared “We are your eyes to the invisible.” www.ASInfrared.com 1-770-570 570-9035 1505 Logan Circle, Cumming GA 30041 E-Mail: Mail: [email protected] Thermographic Report Report Date: 3/08/2011 Twin Rivers Middle School Thermal Imaging Survey Results Twin Rivers Middle School Cafeteria Wall Inside looking out Outside looking in Interior finishes Insulated precast wall Thermal Imaging Survey Results Thermal imaging determined the Twin Rivers Middle School precast walls to be “very energy efficient” with an observed R-Value R of 18.6 Twin Rivers Middle School Media Center Wall, exterior Thermal Imaging Survey Results North Gwinnett Middle School Cafeteria Wall Inside looking out Interior finishes Outside looking in Brick & block cavity wall Thermal Imaging Survey Results Thermal imaging determined the North Gwinnett Middle School brick & block cavity walls to be “energy efficient” with an observed R-Value R of 15.0 Gwinnett Middle School elevation Thermal Imaging Survey Results Lanier School Cafeteria Wall Inside looking out Interior finishes Outside looking in Brick & block cavity wall Thermal Imaging Survey Results Thermal imaging determined the Lanier Middle School brick & block cavity walls to be “energy efficient” with an observed R-Value R of 13.2 Lanier Middle School elevation Thermal Imaging Survey Results Trickum Middle School Classroom Wall Inside looking out Interior finishes Outside looking in Brick & block cavity wall Thermal Imaging Survey Results Thermal imaging determined the Trickum Middle School brick & block cavity walls to be “energy efficient” with an observed R-Value R of 12.7 Trickum Middle School elevation Thermal Imaging Survey Results Actual R-Value Value as measured by Infrared Imaging of walls Total Energy kBtu/SF Twin Rivers MS North Gwinnett MS Lanier MS Trickum MS Average MS Highest using MS 27.0 31.5 32.0 32.5 33.0 48.0 Measured R-Value R-19.2 R-15.0 R-13.2 R-12.7 Review: Energy Analysis of School Projects § § § § Audit and follow-up procedures produces results A thermal efficient design is an effective way to reducing energy costs Review of state-of-the-art high performance exterior walls Sustainable design will lower life cycle costs Thank You for Your Time! This concludes the American Institute of Architects Continuing Education Systems Program. 2011 Southeast Region Conference