RSN200 RSN200
Transcription
RSN200 RSN200
IDMTL EARTH FAULT AND OVERCURRENT RELAY RSN200 Made In Japan W• High Transient Withstand E N • EMC Compliant • Fault Clearance Safety Reset Kasuga Digital IDMTL Type RSN200 Earth Fault and Overcurrent Relay is designed to protect electrical equipment and networks against overcurrent and ground fault. The relay comply to BS 142 and IEC 255. Some useful features of the relay : • User friendly • Compact in size • Earth Fault can be configured to be either IDMTL or DTL • Earth Fault and Overcurrent setting is selectable to either 1.3/10 or 3/10 curve • Wider ranges setting in smaller steps • Recall past % phase trip from memory store in the relay • Fully microprocessor controlled relay • Built in surge arrester to absorb overvoltage/transient • Mechanical trip reset button to guard against automatic reset before fault is identified • High set setting available • Auto and manual scrolling of reading display selectable Layout Display of %A (100%=/5A) indicator O/C & E/F indicator Display of Setting indicator Scroll mode indicator Test Button Display and Setting Selection Keys Trip/Reset Button SPECIFICATIONS 1. Model RSN200 2. Supply Voltage AC230V ± 15% 50/60Hz (other voltages are available) 3. Current Setting Overcurrent: 20- 120% (1% step), 120-200%(5% step) Earth Fault: 4. Time Setting Range Overcurrent IDMTL: 2-50% (1% step) 0.09-3.0 sec at 10 times of setting current (3/10) 0.039-1.3 sec at 10 times of setting current (1.3/10) Earth Fault IDMTL: 0.09-3.0 sec at 10 times of setting current (3/10) 0.039-1.3 sec at 10 times of setting current (1.3/10) DTL: 0.1-2.0 sec (0.1 sec step) 5. High-set (Instantaneous protection) 2.0-10.0 times of setting current 6. Pick-up current 100~105% of setting current 7. Reset Current Value (Setting Value of pick-up current) - 10% 8. Tripping Relay Mechanical hold type Relay Contact : 1c 250VAC, 5A (cos ø=1) 9. LED indication Real time 3-digit display of individual phase Current with auto/manual scroll Digital display for setting parameters Trip current indication for individual phase R = Red colour, S = Yellow colour, T = Blue colour, E/F = Green colour Scroll = Red colour Auxilliary power supply = Green LED % (A) = Red colour, Check = Red colour 10. Life Electrical and Mechanical more than 10,000 operation 11. Enclosure Standard DIN case: Protection structure : Material: Weight: DIN 96 x 96 x 108mm, (Panel cutout 91±0.8 x 91±0.8 mm) IP 30 ABS resin complying with UL94VO Relay: Approx. 500g Characteristics 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Ambient temperature Ambient humidity Voltage accuracy Repeat accuracy Time multiplier accuracy -10 ~ +50°C 45 ~ 85% RH <±3% <±3% <±4% or ±60m sec whichever is greater (10 times of setting current) Multiple of setting current 2 5 10 20 Accuracy ±10% or ±150m sec whichever is the greater ±6% or ±90m sec whichever is the greater ±4% or ±60m sec whichever is the greater ±4% or ±60m sec whichever is the greater Temperature accuracy Insulation resistance Withstand overcurrent Power consumption C.T. input consumption 11. Voltage withstand <±10% at 20±20°C >100MΩ 20 times for 3 sec – (100A for O/C, 20A for E/F) Approx. 3.5VA O/C Approx. 0.12VA at 5A E/F Approx. 0.02VA at 1A 2 KV for 1 minute between all case terminals connected together and the case earth terminal 1.5KV for a minute between independent circuit including contact circuit IDMTL EARTH FAULT AND OVERCURRENT RELAY RSN200 Environmental Withstand 1. Impulse test 5KV peak, 1.2/50µ sec (0.5J) between all terminals and case, earth and between adjacent terminal 2. Temperature IEC 68-2-1 / 68-2-2 Storage and transit - 25°C to + 70°C 3. Humidity IEC 68-2-3 56 days @ 93% RH and + 40°C 4. Vibration IEC 255-21-1 0.5G between 10 Hz and 150 Hz 5. Electromagnetic wave Non-operation for radio frequency at 130-180MHz and 900-1000MHz (by Walkie talkie of 5W) 6. Electrostatic discharge IEC 61000-4-2 Air discharge method ±8KV Contact discharge method ± 6 KV 7. Electrical fast transient/burst IEC 61000-4-4 ± 2KV between power supply terminals Scale Characteristics 1.3/10 Inverse Multiplies of Current X2 Time Multiplier (TM) X3 X5 Standard Operating Time 0.03 0.13 0.08 0.05 0.10 0.44 0.27 0.19 0.15 0.65 0.41 0.28 0.20 0.87 0.55 0.37 0.30 1.31 0.82 0.56 0.40 1.74 1.10 0.74 0.50 2.17 1.37 0.93 0.80 3.48 2.19 1.48 1.00 4.35 2.73 1.86 X3 X5 Scale Characteristics 3/10 Inverse Multiplies of Current X2 Time Multiplier (TM) Standard Operating Time 0.03 0.30 0.19 0.13 0.05 0.50 0.32 0.21 0.10 1.00 0.63 0.43 0.20 2.00 1.26 0.86 0.30 3.00 1.89 1.28 0.50 5.02 3.15 2.14 0.80 8.02 5.04 3.42 1.00 10.03 6.30 4.28 For other setting range, please refer to chart on back page IDMTL EARTH FAULT AND OVERCURRENT RELAY RSN200 Characteristic as per IEC 255-3 and BS 142 TIME CURRENT CHARACTERISTIC TIME CURRENT CHARACTERISTIC 100 100 1.3/10 Inverse 3.0/10 Inverse 10 OPERATING TIME (sec) OPERATING TIME (sec) 10 t=1.00 1 t=0.70 t=0.50 t=0.40 t=1.00 t=0.70 t=0.50 1 t=0.40 t=0.30 t=0.20 t=0.30 t=0.10 t=0.20 t=0.10 0.1 t=0.05 0.1 t=0.03 t=0.05 t=0.03 inst. 0.01 1 10 MULTIPLES OF SETTING CURRENT inst. 100 0.01 1 10 100 MULTIPLES OF SETTING CURRENT Exclusive Agent: 51 Kim Keat Road, Unit 05-02 Mun Hean Industrial Building, Singapore 328821. Tel: (65) 6250 0522 Fax: (65) 6253 6885 / (65) 6253 5879 E-mail: [email protected] Website: http://www.munheansingapore.com
Similar documents
IDMTL OVERCURRENT RELAY RSH 207 Series
Electrical and mechanical more than 10,000 operations
More information