www.RenewAire.com • (800) 627-4499 • Fax: (608) 221
Transcription
www.RenewAire.com • (800) 627-4499 • Fax: (608) 221
www.RenewAire.com • (800) 627-4499 • Fax: (608) 221-2824 4510 Helgesen Drive • Madison, Wisconsin 53718 USA In CANADA www.MitsubishiElectric.ca • (905) 475-8989 • Fax: (905) 475-5231 In MEXICO, CENTRAL and SOUTH AMERICA and the CARIBBEAN www.Soler-Palau.com.mx • 52 (222) 2 233 911 • Fax: 52 (222) 2 233 914 Energy Recovery Ventilation: the proven advantages of heat and humidity transfer Improves Indoor Air Quality By providing simultaneous exhaust and fresh air supply, RenewAire reduces the concentration of harmful pollutants in indoor air - an absolute must in schools, offices and smoking environments. Meets Ventilation Codes for Air Exchange Indoor Air Quality Problems Solved! Provides ample ventilation to meet ASHRAE 62 and the International Mechanical Code that now requires two to three more air exchanges than in the past. Controls Excess Moisture Unlike conventional ventilation or basic heat exchangers, RenewAire moderates not only the temperature but the humidity content of incoming air, limiting humidity swings and associated biologic growths. Optimum Cold Weather Performance Recaptures heat otherwise lost to exhaust air while controlling humidity extremes. This greatly reduces the demand on heating equipment - lowering both initial costs and energy bills. Also protects heating coils from freeze damage. Optimum Warm Weather Performance Pre-cools and dehumidifies the fresh airstream by transfer of heat and humidity to the exhaust airstream. This greatly reduces air conditioning demand - lowering both initial costs and energy bills. On retrofits, the ventilation rate of exisitng A/C equipment can be as much as doubled. Energy Saved = Dollars Saved RenewAire’s all-weather performance can cut annual energy bills for heating, cooling and dehumidification of ventilation air by 50% or more. Ideal for Hot or Cold Environments Catalog Page Reference 2 4 5 6 7 8 9 10 12 14 16 18 20 22 24 26 28 30 32 34 Residential Products BR70 BR130 EV70 EV130 EV200 EV300 Commercial Indoor Products EV450IN HE1XINH HE1XINV HE2XINH HE2XINV HE3XINH HE3XINV HE4XINH HE4XINV HE6XIN HE8XIN Commercial Outdoor Products 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 67 67 EV450RT HE1XRT HE1XRTC HE2XRT HE2XRTC HE3XRT HE3XRTC HE4XRT HE4XRTC HE6XRT HE8XRT Applied Products CA-Series PA-Series Commercial Controls HVI Certified AHRI Certified CA/PA Model Number Guide 68 EV/HE Model Number Guide 69 Company History For Technical Support E-mail: [email protected] To Place an Order E-mail: [email protected] Why RenewAirE? INSIDE OUTSIDE Fresh Air to Room Stale Room Air (exhausted to outside) Fixed Partition and Spacer Plates The Static-Plate Core is the Key! Since the early 1980’s, RenewAire has pioneered the use of the patented Lossnay (Registered trademark of Mitsubishi Electric Corporation) exchange core throughout the Americas. Listed below are some of the many reasons why this technology has become the ERV system preferred by leading HVAC professionals around the world. (proprietary resin composite media) Positive Airstream Separation Stale Room Air G5 Outside Air Enhanced Humidity Transfer RenewAire is proud to introduce the fifth generation energy recovery ventilation (ERV) core. • Over 22% more humidity transfer at AHRI summer conditions • reduced pressure drop - among the lowest for static-plate ERV HE1X = 0.65” @ 750 SCFM EV450 = 0.6” @ 450 SCFM In the RenewAire core, fresh air never comes in contact with exhaust air passages. Hydroscopic resin plates separate the two airstreams so effectively that AHRI certifies zero exhaust air transfer at normal, balanced operating conditions. As a result, RenewAire is perfect for controlled exhaust applications such as toilet areas, as well as for food service and health care occupancies. No Condensate or Active Defrost Direct water vapor transfer, driven by vapor pressure, eliminates condensation - and frosting - in virtually all applications and climate zones. No condensation allows for closer plate spacing, resulting in higher efficiencies and easier installations. It also means no need for the dampers or electrical defrost elements that reduce ventilation and rob energy efficiency in competing technologies. Maintenance - Nothing Could Be Easier The scheduled maintenance for RenewAire is so simple, it can be performed by any janitorial staff. No expensive service contracts are necessary because there is no wheel disassembly and washing, no seal or belt adjustments and no complex controls to calibrate. The result is the lowest maintenance cost of any ERV. The Unbeatable RenewAire Warranty Try RenewAire’s ERV Calculation Software at www.ervcalc.renewaire.com RenewAire’s remarkable performance is independently certified by: An investment in RenewAire is protected by a 10-year core warranty (2 years on balance of the unit). This commitment twice as long as coverage on the best wheel products - speaks volumes about RenewAire’s reliability, durability and consistently high performance. Award-Winning Service and Support RenewAire’s team of professionals knows ERV. And our nationwide network of Sales Reps and quality Distributors are ready to serve you locally. When you call our support number, you’ll talk to a knowledgeable factory expert - someone who knows not only our product line, but the best ways to integrate RenewAire with your preferred lines of heating and air conditioning equipment. Residential/Small Commercial Products • Commercial quality, ducted equipment sized to meet required ventilation rates for homes and small commercial buildings. • Positive airstream separation that is critical for smoking environments and bathroom exhaust. • Static-plate technology makes total energy savings practical for small-capacity systems. • No condensate pan or drain required. • May be mounted in any orientation. • Quiet, powerful blowers eliminate the need for air balancing in most applications. • Easiest maintenance of any ERV. • Performance certified by HVI. • Ten year core warranty. Central Exhaust - Use EV Series EA: Exhaust Air to outdoors OA: Outdoor Air intake RA: Room Air to be exhausted FA: Fresh Air to inside NOTE: ERV Blower may be operated separately from Furnace Blower General Exhaust - EV Series (or BR Series mounted to furnace return air which requires furnace blower interconnect) (See manual for additional installation methods.) NOTE: ERV Blower may be operated separately from Furnace Blower PTL Control PBL Control • primary control for EV70, EV130, EV200 & EV300 • runs unit an adjustable amount of time each hour • two wire, low voltage connection to ERV • push button control turns on unit from bathrooms or other intermittent exhaust locations • 20 minute run-time with one touch • push 2x for 40 or 3x for 60 minutes • two wire, low voltage connection to PTL Control 2 (800) 627-4499 • Fax: (608) 221-2824 FM Control • alternate primary control for EV70, EV130, EV200 & EV300 • wires to EV unit and either thermostat or furnace control to turn on furnace blower • six wire, low voltage connection Residential Energy Recovery Ventilators: BR70, BR130, EV70, EV130, EV200 and EV300 Part I - General A. Product Specification 1. Energy Recovery Ventilator (ERV) shall be a packaged unit as manufactured by RenewAire and shall transfer both heat and humidity using static plate core technology. B. Quality Assurance 1. The energy recovery ventilator shall be Certified by the Home Ventilating Institute (HVI) under CSA 439. Both a heating and a cooling test must be run to demonstrate year round energy recovery. 2. Manufacturer shall be able to provide evidence of independent testing of the core by Underwriters Laboratory (UL), verifying a maximum flame spread index (FSI) of 25 and a maximum smoke developed index (SDI) of 50 thereby meeting NFPA 90A and NFPA 90B requirements for materials in a compartment handling air intended for circulation through a duct system. The method of test shall be UL Standard 723. 3. Unit shall be Listed under UL 1812 Standard for Ducted Air to Air Heat Exchangers. The unit must pass commercial flammability requirements and shall not be labeled “For Residential Use Only”. 4. The ERV core shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of ten years from the date of purchase. The balance-of-unit shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of two years from the date of purchase. Part II – Performance A. Energy Transfer The ERV shall be capable of transferring both sensible and latent energy between airstreams. Latent energy transfer shall be accomplished by direct water vapor transfer from one airstream to the other, without exposing transfer media in succeeding cycles directly to the exhaust air and then to the fresh air. B. Passive Frost Control The ERV core shall perform without condensing or frosting under normal operating conditions (defined as outside temperatures above -10°F and inside relative humidity below 40%). Occasional more extreme conditions shall not affect the usual function, performance or durability of the core. No condensate drains will be allowed. C. Continuous Ventilation Unit shall have the capacity to operate continuously without the need for bypass, recirculation, pre-heaters or defrost cycles under normal operating conditions. D. Positive Airstream Separation Water vapor transfer shall be through molecular transport by hydroscopic resin and shall not be accomplished by “porous plate” mechanisms. Exhaust and fresh airstreams shall travel at all times in separate passages and airstreams shall not mix. E. Laminar Flow Airflow through the ERV core shall be laminar over the products entire operating airflow range, avoiding deposition of particulates on the interior of the energy exchange plate material. Part III – Product A. Construction 1. The energy recovery component shall be of fixed-plate cross-flow construction, with no moving parts. 2. No condensate drain pans or drains shall be allowed and unit shall be capable of operating in both winter and summer conditions without generating condensate. 3. The unit case shall be constructed of 24-gauge steel, with lapped corners and zinc plated screw fasteners. The case shall be finished with textured, powder coat paint. 4. Access doors shall provide easy access to blowers, ERV cores and filters. Doors shall have an airtight compression seal using closed cell foam gaskets. 5. Case walls and doors shall be fully insulated with 1 inch, expanded polystyrene foam insulation faced with a cleanable foil face on all exposed surfaces. 6. The ERV cores shall be protected by a MERV-8 rated, spun polyester, disposable filter in both airstreams. 7. The unit shall have a line cord power connection and be supplied with an internal 24 VAC transformer and relay. 8. Standby power draw shall not exceed 1 Watt for the unit along with an optional automatic control. B. Options (Select options based on application requirements) 1. For BR-Series: Through the wall kit and duct collar kit (automatic control is built into the unit standard). 2. For EV-Series: Controls including proportional run time, push button and furnace interlock and a variety of weather hoods. Part IV – Installation A. Unit Location 1. Locate and orient unit to provide the shortest and most straight duct connections. Provide service clearances as indicated on the plans. Locate units distant from sound critical occupancies. 2. Use integral mounting flange and hanging bar system to mount the unit to a structurally suitable surface. The units may be mounted in any orientation. B. Vibration Isolation 1. Utilize factory supplied vibration isolation kit following instructions. 2. Provide flexible duct connections at unit duct flanges. C. Duct Design 1. All ductwork shall be designed, constructed, supported and sealed in accordance with SMACNA HVAC Duct Construction Standards and pressure classifications. 2. At a minimum all duct runs to the outdoors shall be thermally insulated at levels appropriate to the local climate. A continuous vapor barrier shall also be provided on warm surface of the insulation. D. Sound Control 1. To control sound radiated from the unit: a. Provide acoustic treatment in mechanical room walls and ceilings. 2. To control sound associated with the two blower outlets: a. Utilize insulated, flexible duct. b. In sound critical applications provide increased duct sizing and consider the use of sound attenuators. E. Test and Balancing 1. Test and Balancing may not begin until 100% of the installation is complete and fully functional. 2. Follow National Comfort Institute (NCI) air test and balance procedures specific to Heat Recovery Ventilator Balancing Procedure including standard reports to the owner’s representative. 3 www.RenewAire.com BR70 Specifications Indoor Unit Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 40-70 CFM Number Motors: One, 0.08 hp V HZ Phase Input Watts FLA 120 60 Single 94 @ 69 CFM 0.9 Control Voltage: 24 VAC Filters: MERV 8, spun polyester media. 7 1/2” x 10 1/2” x 1” Weight: 39 lbs (unit), 50 lbs (in carton) Shipping Dimensions: 21 1/2”W x 29”L x 14 1/2”H Options: Thru-the-Wall Kit Duct Collar Kit G4 Performance Airflow CFM ESP in H20 Temp EFF% Total EFF% Winter/Summer* 35 0.50 84 75/60 51 0.40 80 71/56 63 0.30 77 68/53 79 0.20 73 64/48 90 0.10 70 61/45 * (See HVI certification report on page 66 for complete certified rating). Dimensions EA: OA: RA: FA: OA (TW) RA (DH) EA (TW) FA (DH) Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside 6 2 17 5/8 1 1/8 TW: Thru Wall DH: Duct Hung CUT HOLE IN DUCT (MINIMUM SIZE) TOP VIEW OA (TW) RA (DH) 36" LINE CORD EA (TW) FA (DH) RA (TW) OA (DH) FA (TW) EA (DH) 6 DIA 10 5/8 SIDE VIEW 24 VAC CONTROL TERMINAL 27 1/8 18 1/2 SERVICE AREA PROPORTIONAL RUNTIME CONTROL 18 1/4 RIGHT VIEW 5 4 1/2 BOTTOM VIEW (DOOR REMOVED) 4 (800) 627-4499 • Fax: (608) 221-2824 8 DIA BR130 Specifications Indoor Unit Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 50-140 CFM Unit may be mounted in any orientation Number Motors: One, 0.1 hp V HZ Phase Input Watts FLA 120 60 Single 121 @ 124 CFM 1.3 Control Voltage: Built in proportional runtime control and switched terminals for furnace / AC interconnect Filters: MERV 8, spun polyester media. 10 1/2” x 10 1/2” x 1” Weight: 49 lbs (unit), 60 lbs (in carton) G4 Performance Shipping Dimensions: 21”W x 32”L x 17 1/2”H Airflow CFM ESP in H20 Temp EFF% Total EFF% Winter/Summer* 52 0.70 83 75/60 69 0.60 80 72/57 94 0.50 76 67/52 113 0.40 73 64/48 132 0.30 70 60/44 141 0.20 68 59/43 148 0.10 67 57/41 Options: Thru-the-Wall Kit Duct Collar Kit * (See HVI certification report on page 66 for complete certified rating). Dimensions OA (TW) RA (DH) EA: OA: RA: FA: EA (TW) FA (DH) 6 2 1 1/8 OA (TW) RA (DH) TW: Thru Wall DH: Duct Hung CUT HOLE IN DUCT (MINIMUM SIZE) 20 1/2 TOP VIEW Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside 36" LINE CORD EA (TW) FA (DH) 4 3/4 6 1/8 RA (TW) OA (DH) SIDE VIEW FA (TW) EA (DH) 6 DIA 24 VAC CONTROL TERMINAL 30 7/8 8 DIA 13 3/8 18 1/2 SERVICE AREA PROPORTIONAL RUNTIME CONTROL 18 1/4 RIGHT VIEW 5 4 1/2 BOTTOM VIEW (DOOR REMOVED) 5 www.RenewAire.com EV70 Specifications Indoor Unit Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 40-70 CFM Unit may be mounted in any orientation Number Motors: One, 0.08 hp V HZ Phase Input Watts FLA 120 60 Single 94 @ 69 CFM 0.9 Control Voltage: 24 VAC Filters: MERV 8, spun polyester media. 7 1/2” x 10 1/2” x 1” Weight: 39 lbs (unit), 48 lbs (in carton) Shipping Dimensions: 21 1/2”W x 29”L x 14 1/2”H G4 Performance Airflow CFM ESP in H20 Temp EFF% Total EFF% Winter/Summer* 46 0.40 81 74/60 59 0.30 78 71/57 73 0.20 74 68/53 86 0.10 71 64/49 Options: PTL - Percentage Timer Control PBL - Push Button Point-of-Use Controls FM - Percentage Timer Control with Furnace Interlock DH24 - Dehumidistat Control Wall Caps * (See HVI certification report on page 66 for complete certified rating). Dimensions 34" Line Cord Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside 4 1/2" 4 1/8" EA: OA: RA: FA: 10 1/8" Blowers Interlock Switch 25 1/8" 8" Line Cord 5 1/2" 6" RA Filters EA FA Energy Transfer Core FRONT VIEW 27 7/8" Service Access RIGHT VIEW 6 (800) 627-4499 20 1/8" 8 1/8" 9 1/8" OA 6" 24 Volt AC Control Terminal 6" 5 1/2" TOP VIEW • Fax: (608) 221-2824 EV130 Specifications Indoor Unit Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 50-140 CFM Unit may be mounted in any orientation Number Motors: One, 0.1 hp V HZ Phase Input Watts FLA 120 60 Single 121 @ 124 CFM 1.2 Control Voltage: 24 VAC Filters: MERV 8, spun polyester media. 10 1/2” x 10 1/2” x 1” Weight: 49 lbs (unit), 58 lbs (in carton) Shipping Dimensions: 21”W x 32”L x 17 1/2”H G4 Performance Airflow CFM ESP in H20 Temp EFF% Total EFF% Winter/Summer* 52 0.70 83 75/60 69 0.60 80 72/57 94 0.50 76 67/52 113 0.40 73 64/48 132 0.30 70 60/44 141 0.20 68 59/43 148 0.10 67 57/41 Options: PTL - Percentage Timer Control PBL - Push Button Point-of-Use Controls FM - Percentage Timer Control with Furnace Interlock DH24 - Dehumidistat Control Wall Caps * (See HVI certification report on page 66 for complete certified rating). Dimensions 6 3/8" 4 1/8" EA: OA: RA: FA: Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside 34" Line Cord 13" 5 1/2" TOP VIEW 8" Blowers Interlock Switch Line Cord 6" 28 3/4" 5 1/2" 6" RA Filters Energy Transfer Core EA 20 1/8" 8 1/8" OA 9 1/8" 6" 24 Volt AC Control Terminal FA 30 5/8" Service Access RIGHT VIEW FRONT VIEW 7 www.RenewAire.com EV200 Specifications Indoor Unit Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 100-200 CFM Number Motors: One, 0.1 hp V HZ Phase Input Watts FLA 120 60 Single 157 @ 181 CFM 1.5 Control Voltage: 24 VAC Filters: MERV 8, spun polyester media. 10 1/2” x 21 3/4” x 1” Weight: 70 lbs (unit), 82 lbs (in carton) Shipping Dimensions: 21 1/2”W x 32”L x 29”H G4 Performance Airflow CFM ESP in H20 Temp EFF% Total EFF% Winter/Summer* 122 0.70 82 74/59 149 0.65 80 72/56 168 0.50 79 70/55 176 0.40 78 69/54 186 0.30 77 68/53 192 0.20 77 68/52 200 0.10 76 67/52 Options: PTL - Percentage Timer Control PBL - Push Button Point-of-Use Controls FM - Percentage Timer Control with Furnace Interlock DH24 - Dehumidistat Control Wall Caps * (See HVI certification report on page 66 for complete certified rating). EA: OA: RA: FA: 11 7/8" 11 7/8" Dimensions Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside 34" Line Cord TOP VIEW 23 7/8" Interlock Switch Blowers Line Cord 6" 6" 6" EA 20 1/8" 8 1/8" 9 1/8" 5 1/2" RA 5 1/2" 28 3/4" OA 8" 24 Volt AC Control Terminal FA 41 1/2" Service Access Filters Energy Transfer Core FRONT VIEW RIGHT VIEW 8 (800) 627-4499 • Fax: (608) 221-2824 EV300 Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 150-300 CFM Number Motors: One, 0.2 hp V HZ Phase Input Watts FLA 120 60 Single 310 @ 293 CFM 3.3 Control Voltage: 24 VAC Filters: MERV 8, spun polyester media. 10 1/2” x 21 3/4” x 1” Weight: 72 lbs (unit), 85 lbs (in carton) Shipping Dimensions: 21 1/2”W x 32”L x 29”H G4 Performance Airflow CFM ESP in H20 Temp EFF% Total EFF% Winter/Summer* 155 1.0 80 70/51 199 0.9 76 67/48 249 0.8 72 62/44 268 0.7 71 61/42 289 0.6 69 58/39 300 0.5 68 57/38 310 0.4 67 56/37 Options: PTL - Percentage Timer Control PBL - Push Button Point-of-Use Controls FM - Percentage Timer Control with Furnace Interlock DH24 - Dehumidistat Control 8” Wall Caps * (See HVI certification report on page 66 for complete certified rating). Dimensions 10" EA: OA: RA: FA: 9 3/4" Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside 34" Line Cord To Fit 8" Duct TOP VIEW 23 7/8" Interlock Switch Blowers 28 3/4" 5 1/2" 5 1/2" OA 7 3/8" EA 9 1/8" 9 1/8" RA 8 3/4" 24 Volt AC Control Terminal 5 1/2" 5 1/2" FA 20 1/8" 41 1/2" Service Access Filters Line Cord Energy Transfer Core FRONT VIEW RIGHT VIEW 9 www.RenewAire.com Commercial INDOOR Products • Horizontal and vertical configuration. • Wide range of airflow and static capacities. • AHRI certified performance data for efficiency and cross leakage. • UL tested flammability and smoke generation that meets NFPA 90A and 90B test standards for commercial applications. • Easy installation and service. • Ten year core warranty. RenewAire means Trouble-Free ERV. EA: OA: RA: FA: 10 (800) 627-4499 • Fax: (608) 221-2824 Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside Packaged Indoor Energy Recovery Ventilators: EV450IN, HE1XIN, HE2XIN, HE3XIN, HE4XIN, HE6XIN, HE8XIN Part I - General Part III – Product A. Product Specification A. Construction 1. Energy Recovery Ventilator (ERV) shall be a packaged unit as manufactured by RenewAire and shall transfer both heat and humidity using static plate core technology. 1. The energy recovery component shall be of fixed-plate cross-flow construction, with no moving parts. B. Quality Assurance 1. The energy recovery cores used in these products shall be third party Certified by AHRI under its Standard 1060 for Energy Recovery Ventilators. AHRI published certifications shall confirm manufacture’s published performance for airflow, static pressure, temperature and total effectiveness, purge air (OACF) and exhaust air leakage (EATR). Products that are not currently AHRI Certified will not be accepted. 2. Manufacturer shall be able to provide evidence of independent testing of the core by Underwriters Laboratory (UL), verifying a maximum flame spread index (FSI) of 25 and a maximum smoke developed index (SDI) of 50 thereby meeting NFPA 90A and NFPA 90B requirements for materials in a compartment handling air intended for circulation through a duct system. The method of test shall be UL Standard 723. 3. Unit shall be Listed under UL 1812 Standard for Ducted Air to Air Heat Exchangers. (Note that a few low volume product or product configurations are not UL Listed.) 4. The ERV core shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of ten years from the date of purchase. The balance-of-unit shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of two years from the date of purchase. Part II – Performance 2. No condensate drain pans or drains shall be allowed and unit shall be capable of operating in both winter and summer conditions without generating condensate. 3. The unit case shall be constructed of G90 galvanized, 20-gauge steel, with lapped corners and zinc plated screw fasteners. 4. Access doors shall provide easy access to blowers, ERV cores and filters. Doors shall have an airtight compression seal using closed cell foam gaskets. 5. Case walls and doors shall be insulated with 1 inch, 4 pound density, foil/scrim faced, high-density fiberglass board insulation, providing a cleanable surface and eliminating the possibility of exposing the fresh air to glass fibers. 6. The ERV cores shall be protected by a MERV-8 rated, 2” nominal, pleated, disposable filter in both airstreams. 7. Unit shall have single-point power connection and a single-point 24 VAC contactor control connection (except Inverter Ready units that have terminal connections for an independent inverter for each airstream). 8. Blower motors shall be EPACT compliant for energy efficiency and be thermally protected or supplied with external starters. 9. Blowers shall be quiet running, forward curve type and be either direct drive or belt drive. HE6X and HE8X units use backward incline, belt drive blower packages. Belt drive motors shall be provided with adjustable pulleys and motor mounts allowing for proper belt tensioning. A. Energy Transfer The ERV shall be capable of transferring both sensible and latent energy between airstreams. Latent energy transfer shall be accomplished by direct water vapor transfer from one airstream to the other, without exposing transfer media in succeeding cycles directly to the exhaust air and then to the fresh air. B. Passive Frost Control The ERV core shall perform without condensing or frosting under normal operating conditions (defined as outside temperatures above -10°F and inside relative humidity below 40%). Occasional more extreme conditions shall not affect the usual function, performance or durability of the core. No condensate drains will be allowed. C. Continuous Ventilation Unit shall have the capacity to operate continuously without the need for bypass, recirculation, pre-heaters or defrost cycles under normal operating conditions. B. Options (Select options based on application requirements.) 1. Provide unit and duct connection orientation per project schedule. 2. Provide double wall construction with 24-gauge galvanized steel liner. 3. Units are available single or three phase at a full range of operating voltages. See project schedule. 4. Provide motor horsepower as specified in project schedule. 5. Provide “inverter-ready” units which include shielded power wiring and terminal connections for inverters (inverters provided and installed by others). 6. Provide factory installed fused disconnects. 7. Provide factory installed non-fused disconnects. D. Positive Airstream Separation Water vapor transfer shall be through molecular transport by hydroscopic resin and shall not be accomplished by “porous plate” mechanisms. Exhaust and fresh airstreams shall travel at all times in separate passages and airstreams shall not mix. 8. Provide factory installed transformer/relay package to supply a 24 VAC power source. 9. Provide factory installed filter monitors for each airstream. E. Laminar Flow Airflow through the ERV core shall be laminar over the products entire operating airflow range, avoiding deposition of particulates on the interior of the energy exchange plate material. 11 www.RenewAire.com EV450IN Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 200-500 CFM AHRI 1060 Certified Core: One L85 Airflow Rating Points (for AHRI): 450 CFM and 338 CFM Motors: One, 0.6 hp (Single Phase) One, 0.5hp (Three Phase) V HZ Phase FLA 115 60 Single 7.0 208-230 60 Single 3.5 277 60 Single 2.4 208-230 60 Three 1.7-1.5 460 60 Three 0.8 G5 Performance Airflow CFM ESP in H 20 Watts 1P 3P Temp EFF% Total EFF% Winter/Summer* 225 1.25 335 181 81 76/66 338 1.00 420 278 77 71/61 380 0.90 470 340 75 69/59 450 0.65 550 430 73 66/56 540 0.25 640 540 70 62/52 575 0.00 690 610 69 61/51 600 -0.25 735 664 68 60/50 Control Voltage: 24 VAC Filters: Two total, MERV 8, 2” pleated, 14” x 20” nominal size Weight: 141 lbs (unit), 160 lbs (in carton), up to 3 units on 50 lb pallet Shipping Dimensions: 37 1/2” W x 48” L x 17” H Options: 45EVHB - Hanging Bracket, Foot Kit 45EVDF - Rectangular 12” x 8” Flange Kit (2 in kit) 45EVT10 - 10” Round Transition Kit (2 in kit) *At AHRI 1060 standard conditions (See certified data on page 67 for core components.) 12 (800) 627-4499 • Fax: (608) 221-2824 www.RenewAire.com 13 2 1/8" 4 1/4" 36 3/8" 32" 20 1/4" 16 1/8" 36 3/8" 32" 20 1/4" 16 1/8" 10" 2 1/8" 10" 4 1/4" 1 1/4" FRONT VIEW 44 1/8" 8" 8" 8" Optional Transitions (45EVT10) shown FA RA Control Wire Entry 7/8" Dia. Power Supply Entry 7/8" Dia. EA FRONT VIEW (Doors removed) 18" 8" 8" TOP VIEW 13 1/4" 16" 33 7/8" OA Optional 45EVT10-10" Round Transition Kit Shown LEFT VIEWS RA OA O "R 0 O1 6 3/8" D UN All other Access: Screw-attached panel Filter Access: Hinged and Latched Door 2 1/8" 34 1/8" Service Area 36 3/8" 35 1/4" RIGHT VIEWS FA EA Optional 45EVDF Rectangular 12" X 8" Flange Kit Shown 5 1/4" 8 3/4" 1" 6 1/2" Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside 13 1/4" 1" 1 1/2" Clearance required to remove doors from hinges. 11 1/8" Unit Dimensions 25 1/8" EA: OA: RA: FA: 3 1/4" 5 3/8" 4 3/4" 2 1/8" 11 5/8" Alternate Power Supply Entry 7/8" Dia. 4 1/4" EV450IN 26 1/4" 10 1/8" 16 1/8" 20 3/8" 24 7/8" 16 1/8" 20 1/4" 32" HE1XINH Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 250-925 CFM AHRI 1060 Certified Core: One L125-00 Airflow Rating Points (for AHRI): 750 CFM and 560 CFM Number Motors: Two V HZ Phase FLA Min. Cir. Amps Max. Fuse Size 115 60 Single 8.6 19.4 25 208-230 60 Single 4.3 9.7 15 277 60 Single 2.4 5.4 15 208-230 60 Three 2.1 5.2 15 460 60 Three 1.1 2.6 15 G5 Performance CFM Effectiveness (%) 250 500 Control Voltage: 24 VAC 750 1,000 Filters: Two total, MERV 8, 2” pleated, 20” x 20” nominal size Weight: 211 lbs (unit), 250 lbs (shipping weight) 80 Sensible Winter 60 Summ Shipping Dimensions: 44” W x 56” L x 27” H Total er To tal 40 *At AHRI 1060 standard conditions (See certified data on page 67 for core components.) Airflow Performance Motor HP Phase External Static Pressure (Inches Water Column) 0.0 0.25 0.5 0.75 1.0 1.25 1.5 0.75 (Two DD) Single Phase 970 CFM 1,490 Watts 925 CFM 1,375 Watts 860 CFM 1,270 Watts 795 CFM 1,160 Watts 720 CFM 1,030 Watts 635 CFM 950 Watts 350 CFM 750 Watts 0.75 (Two DD) Three Phase 1,030 CFM 1,220 Watts 1,010 CFM 1,210 Watts 975 CFM 1,160 Watts 880 CFM 1,050 Watts 800 CFM 990 Watts 700 CFM 850 Watts 530 CFM 720 Watts 14 (800) 627-4499 • Fax: (608) 221-2824 www.RenewAire.com 15 FA EA LEFT VIEW 9 1/2" 28 3/8" 12 7/8" 8 5/8" Ø12" TYP 20 5/8" FA 34 7/8" Case EA Power Wiring Inlet 7/ 8" Dia. Control Wiring Inlet 7/8" Dia. 50 1/8" Maximum Door Extension Alternate Control Wiring Inlet 7/8" Dia. Alternate Power Wiring Inlet 7/8" Dia. Unit Dimensions HE1XINH FRONT VIEW 49 1/8" Case RA OA 36 3/8" Overall 28 1/4" 9 5/8" RIGHT VIEW RA OA 10 3/8" 21 3/4" Overall Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside 40 5/8" Minimum Service Area (Doors can be taken off hinges.) TOP VIEW 54 3/4" Overall EA: OA: RA: FA: HE1XINV Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 250-925 CFM AHRI 1060 Certified Core: One L125-00 Airflow Rating Points (for AHRI): 750 CFM and 560 CFM Number Motors: Two V HZ Phase FLA Min. Cir. Amps Max. Fuse Size 115 60 Single 8.6 19.4 25 208-230 60 Single 4.3 9.7 15 277 60 Single 2.4 5.4 15 208-230 60 Three 2.1 5.2 15 460 60 Three 1.1 2.6 15 G5 Performance CFM Effectiveness (%) 250 500 Control Voltage: 24 VAC 750 1,000 Filters: Two total, MERV 8, 2” pleated, 20” x 20” nominal size Weight: 211 lbs (unit), 250 lbs (shipping weight) 80 Sensible Winter 60 Summ Shipping Dimensions: 44” W x 56” L x 27” H Total er To tal 40 *At AHRI 1060 standard conditions (See certified data on page 67 for core components.) Airflow Performance Motor HP Phase External Static Pressure (Inches Water Column) 0.0 0.25 0.5 0.75 1.0 1.25 1.5 0.75 (Two DD) Single Phase 970 CFM 1,490 Watts 925 CFM 1,375 Watts 860 CFM 1,270 Watts 795 CFM 1,160 Watts 720 1,030 CFM Watts 635 950 CFM Watts 350 750 CFM Watts 0.75 (Two DD) Three Phase 1,030 CFM 1,220 Watts 1,010 1,210 975 CFM 1,160 Watts 880 CFM 1,050 Watts 800 990 CFM Watts 700 850 CFM Watts 530 720 CFM Watts CFM Watts 16 (800) 627-4499 • Fax: (608) 221-2824 www.RenewAire.com 17 41 5/8" Control Wiring Inlet 7/8" Dia. Power Wiring Inlet 7/8" Dia. 17" 10 3/8" 12 7/8" FA RA Unit Dimensions P LEFT VIEW Ø FA RA FRONT VIEW 34 7/8" Case TOP VIEW 40 3/8" Overall EA OA EA OA 21 3/4" Overall 10 3/8" RIGHT VIEW 50 1/8" Maximum Door Extension 40 5/8" Minimum Service Area (Doors can be taken off hinges.) 41 1/2" TY 12 " Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside 17" EA: OA: RA: FA: 50 5/8" HE1XINV 51 3/8" Overall 20 5/8" 49 1/8" Case HE2XINH Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 500-2,000 CFM AHRI 1060 Certified Core: Two L125-00 Airflow Rating Points (for AHRI): 1,500 CFM and 1,120 CFM Number Motors: Direct Drive (DD) Four, Belt Drive (BD) Two Drive HP Volts HZ Phase FLA Min. Cir. Amps Max. Fuse Size DD 0.75 115 208-230 277 208-230 460 60 60 60 60 60 Single Single Single Three Three 8.6 4.3 2.4 2.1 1.1 36.6 18.3 10.2 9.8 4.9 45 20 15 15 15 BD 1.5 208-230 208-230 460 575 60 60 60 60 Single Three Three Three 9.3-9.0 4.8-4.8 2.4 1.8 20.9 10.8 5.4 4.1 30 15 15 15 BD 2 208-230 208-230 460 575 60 60 60 60 Single Three Three Three 11.3-10.5 6.2-6.2 3.1 2.3 25.4 14.0 7.0 5.2 35 20 15 15 G5 Performance CFM Effectiveness (%) 500 1,000 1,500 2,000 80 Sensible Winter Total 60 Control Voltage: 24 VAC Filters: Four total, MERV 8, 2” pleated, 20” x 20” nominal size Summ er To tal Weight: 414 lbs (unit), 420 lbs (shipping weight) 40 Shipping Dimensions: 50” W x 62” L x 41” H *At AHRI 1060 standard conditions (See certified data on page 67 for core components.) Airflow Performance External Static Pressure (Inches Water Column) Motor HP Blower RPM Nominal Turns Open 0.0 0.25 0.5 0.75 1.0 1.25 0.75 (Four DD) Single Phase N/A N/A N/A N/A 1,950 CFM 2,240 Watts 1,830 CFM 2,155 Watts 1,670 CFM 2,020 Watts 1,400 CFM 1,795 Watts 1,150 CFM 1,490 Watts 700 CFM 1,190 Watts 0.75 (Four DD) Three Phase N/A N/A N/A N/A 1,960 CFM 2,500 Watts 1,840 CFM 2,300 Watts 1,700 CFM 2,125 Watts 1,600 CFM 1,900 Watts 1,380 CFM 1,700 Watts 1,190 CFM 1,500 Watts 1.5 - - 800 CFM 1,260 Watts CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 1.5 (BD) 1,000 1,230 1,420 4.5 2 0 1,378 1,694 1,956 0.5 0.9 1.4 1,175 1,550 1,850 0.5 0.9 1.4 900 1,335 1,680 0.4 0.8 1.2 635 1,125 1,475 0.4 0.7 1.2 1,000 1,300 0.7 1.1 500 1,200 0.6 1.1 930 0.9 2 (BD) 1,220 1,470 1,660 4.5 2 0 1,681 2,025 - 0.9 1.6 - 1,530 1,925 - 0.9 1.5 - 1,315 1,750 2,000 0.7 1.4 2.0 1,100 1,575 1,900 0.7 1.3 1.9 975 1,375 1,750 0.6 1.2 1.8 1,275 1,570 1.2 1.7 1,125 1,475 1.1 1.7 Note: Brake Horse Power (BHP) is for one blower motor package only. 18 (800) 627-4499 • Fax: (608) 221-2824 19 5/8" 20 5/8" 2 3/4" 3 1/2" Wiring Entry 7/8" Dia. LEFT VIEW Direct Drive Version EA FA LEFT VIEW Belt Driven Version EA 33" FA FRONT VIEW 49 1/4" case TOP VIEW 59" Service Area OA RIGHT VIEW OA RA 24" TYP 8" 41 1/4" Note: Door lifts away. Filters RA 60" Service Area Note: All duct flanges are 14" x 24". EA E-Box E-Box 35 1/4" Case FA 54 7/8" overall Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside 21 5/8" 14" typ 2 7/8" Unit Dimensions 34 3/4" EA: OA: RA: FA: 36 5/8" HE2XINH 15 3/8" www.RenewAire.com 19 HE2XINV Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 500-2,000 CFM AHRI 1060 Certified Core: Two L125-00 Airflow Rating Points (for AHRI): 1,500 CFM and 1,120 CFM Number Motors: Direct Drive (DD) Four, Belt Drive (BD) Two Drive HP Volts HZ Phase FLA Min. Cir. Amps Max. Fuse Size DD 0.75 115 208-230 277 208-230 460 60 60 60 60 60 Single Single Single Three Three 8.6 4.3 2.4 2.1 1.1 36.6 18.3 10.2 9.8 4.9 45 20 15 15 15 BD 1.5 208-230 208-230 460 575 60 60 60 60 Single Three Three Three 9.3-9.0 4.8-4.8 2.4 1.8 20.9 10.8 5.4 4.1 30 15 15 15 BD 2 208-230 208-230 460 575 60 60 60 60 Single Three Three Three 11.3-10.5 6.2-6.2 3.1 2.3 25.4 14.0 7.0 5.2 35 20 15 15 G5 Performance CFM Effectiveness (%) 500 1,000 1,500 2,000 80 Sensible Winter Total 60 Control Voltage: 24 VAC Filters: Four total, MERV 8, 2” pleated, 20” x 20” nominal size Summ er To tal Weight: 399 lbs (unit), 420 lbs (shipping weight) 40 Shipping Dimensions: 48” W x 62” L x 55” H *At AHRI 1060 standard conditions (See certified data on page 67 for core components.) Airflow Performance External Static Pressure (Inches Water Column) Blower RPM Nominal Turns Open 0.0 0.25 0.5 0.75 1.0 1.25 0.75 (Four DD) Single Phase N/A N/A N/A N/A 1,870 CFM 2,160 Watts 1,720 CFM 2,070 Watts 1,520 CFM 1,900 Watts 1,290 CFM 1,715 Watts 1,080 CFM 1,505 Watts 700 CFM 1,210 Watts 0.75 (Four DD) Three Phase N/A N/A N/A N/A 1,870 CFM 2,500 Watts 1,720 CFM 2,300 Watts 1,540 CFM 2,125 Watts 1,350 CFM 1,950 Watts 1,240 CFM 1,730 Watts 1,030 CFM 1,490 Watts Motor HP 1.5 - - 800 CFM 1,240 Watts CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 1.5 (BD) 1,000 1,230 1,420 4.5 2 0 1,378 1,694 1,956 0.5 0.9 1.4 1,175 1,550 1,850 0.5 0.9 1.4 900 1,335 1,680 0.4 0.8 1.2 635 1,125 1,475 0.4 0.7 1.2 1,000 1,300 0.7 1.1 500 1,200 0.6 1.1 930 0.9 2 (BD) 1,220 1,470 1,660 4.5 2 0 1,681 2,025 - 0.9 1.6 - 1,530 1,925 - 0.9 1.5 - 1,315 1,750 2,000 0.7 1.4 2.0 1,100 1,575 1,900 0.7 1.3 1.9 975 1,375 1,750 0.6 1.2 1.8 430 1,275 1,570 0.6 1.2 1.7 1,125 1,475 1.1 1.7 Note: Brake Horse Power (BHP) is for one blower motor package only. 20 (800) 627-4499 • Fax: (608) 221-2824 www.RenewAire.com 21 19 3/8" LEFT END VIEW DIRECT DRIVE E-box power wire 7/8" Dia. FA RA LEFT END VIEW 6 3/8" BELT DRIVE FA RA Unit Dimensions HE2XINV 5 7/8" FA FRONT VIEW 38 3/4" 35 1/4" w/ screws Note: All duct flanges are 14" x 24". 19 3/8" 43 3/4" EA OA TOP VIEW and Service Area RA 4 1/4" 74 7/8" Clear 34 1/8" 39 1/4" 49 1/8" 14" 8 1/8" 3 1/2" RIGHT END VIEW DIRECT DRIVE EA OA 24" 41 1/2" RIGHT END VIEW BELT DRIVE EA 35 5/8" 50 5/8" Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside OA EA: OA: RA: FA: HE3XINH Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 750-3,300 CFM AHRI 1060 Certified Core: Three L125-00 Airflow Rating Points (for AHRI): 2,250 CFM and 1,690 CFM Number Motors: Two G5 Performance HP Volts HZ Phase FLA Min. Cir. Amps Max. Fuse Size 2 208-230 208-230 460 575 60 60 60 60 Single Three Three Three 11.3-10.5 6.2-6.2 3.1 2.3 25.4 14.0 7.0 5.2 35 20 15 15 3 208-230 208-230 460 575 60 60 60 60 Single Three Three Three 13.7 9.2-8.6 4.3 3.2 30.8 20.7 9.7 7.2 45 30 15 15 5 208-230 460 575 60 60 60 Three Three Three 14.0-13.0 6.5 5.0 31.5 14.6 11.3 45 20 15 CFM Effectiveness (%) 1,500 2,000 2,500 3,000 80 Control Voltage: 24 VAC Sensible Winter 60 Filters: Six total, MERV 8, 2” pleated, 20” x 20” nominal size Total Summ Weight: 675 lbs (unit), 700 lbs (shipping weight) Shipping Dimensions: 72” W x 84” L x 46” H er To tal 40 *At AHRI 1060 standard conditions (See certified data on page 67 for core components.) Airflow Performance External Static Pressure (Inches Water Column) Motor HP Blower RPM Nominal Turns Open 0.0 CFM 0.25 BHP CFM 0.5 BHP CFM 0.75 BHP CFM 1.0 BHP CFM 1.25 BHP CFM 1.5 BHP CFM BHP 2 1,095 1,220 1,340 4 2 0 2,040 2,340 2,590 1.3 1.5 1.8 1,760 2,110 2,370 1.3 1.4 1.7 1,370 1,790 2,130 1.2 1.3 1.6 920 1,380 1,760 1.1 1.2 1.4 940 1,310 1.2 1.3 980 1.2 - - 3 1,345 1,535 1,685 4.5 2 0 2,420 2,850 - 2.3 2.8 - 2,280 2,760 - 2.2 2.7 - 2,090 2,570 - 2.1 2.6 - 1,760 2,380 2,660 2.0 2.5 2.9 1,280 2,090 2,470 1.9 2.4 2.7 860 1,810 2,280 1.9 2.2 2.6 1,330 2,000 2.1 2.4 5 1,495 1,675 1,855 6.5 3.5 0 2,850 3,280 - 3.1 3.8 - 2,710 3,140 - 3.0 3.7 - 2.520 2,990 3,470 2.9 3.5 4.9 2,280 2,800 3,330 2.8 3.3 4.7 2,040 2,610 3,140 2.7 3.1 4.5 1,620 2,380 3,040 2.5 2.9 4.4 1,140 2,090 2,760 2.4 2.7 4.0 22 (800) 627-4499 • Fax: (608) 221-2824 12" Left View FA EA 62 1/4" 12" 39" E-box FA EA 55 1/8" Control Wiring Inlet 58 1/8" Power Wiring Inlet E-box Note: There are two 12" x 12" discharges. 5 1/2" Unit Dimensions 18 5/8" Front View 57 1/4" Top View 64 1/2" Service Area 64 1/2" overall 62 1/4" RA OA 97" Service Area Right View RA 12" X 34" 62 1/4" 4 1/4" OA 12" X 34" Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside 5 1/8" 26 1/8" EA: OA: RA: FA: 40 3/8" HE3XINh 40 3/8" 22 3/8" www.RenewAire.com 23 HE3XINV Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 750-3,300 CFM AHRI 1060 Certified Core: Three L125-00 Airflow Rating Points (for AHRI): 2,250 CFM and 1,690 CFM Number Motors: Two G5 Performance HP Volts HZ Phase FLA Min. Cir. Amps Max. Fuse Size 2 208-230 208-230 460 575 60 60 60 60 Single Three Three Three 11.3-10.5 6.2-6.2 3.1 2.3 25.4 14.0 7.0 5.2 35 20 15 15 3 208-230 208-230 460 575 60 60 60 60 Single Three Three Three 13.7 9.2-8.6 4.3 3.2 30.8 20.7 9.7 7.2 45 30 15 15 5 208-230 460 575 60 60 60 Three Three Three 14.0-13.0 6.5 5.0 31.5 14.6 11.3 45 20 15 CFM Effectiveness (%) 1,500 2,000 2,500 3,000 80 Control Voltage: 24 VAC Sensible Winter 60 Filters: Six total, MERV 8, 2” pleated, 20” x 20” nominal size Total Summ Weight: 640 lbs (unit), 675 lbs (shipping weight) er To Shipping Dimensions: 45” W x 70” L x 70” H tal 40 *At AHRI 1060 standard conditions (See certified data on page 67 for core components.) Airflow Performance External Static Pressure (Inches Water Column) Motor HP Blower RPM Nominal Turns Open 0.0 CFM 0.25 BHP CFM 0.5 BHP CFM 0.75 BHP CFM 1.0 BHP CFM 1.25 BHP CFM 1.5 BHP CFM BHP 2 1,095 1,220 1,340 4 2 0 1,900 2,200 2,300 1.3 1.5 1.7 1,600 1,960 2,160 1.2 1.4 1.6 1,250 1,610 1,950 1.2 1.3 1.5 850 1,240 1,580 1.1 1.3 1.4 860 1,150 1.2 1.3 800 1.2 - - 3 1,345 1,535 1,685 4.5 2 0 2,400 2,720 - 2.2 2.7 - 2,250 2,450 2,870 2.2 2.5 3.0 1,970 2,250 2,740 2.1 2.4 2.9 1,570 1,950 2,540 2.0 2.3 2.8 1,170 1,650 2,340 1.9 2.2 2.7 900 1,200 2,090 1.8 2.0 2.5 875 1,800 1.9 2.4 5 1,495 1,675 1,855 6.5 3.5 0 2,850 3,230 3.520 2.7 3.7 4.5 2,610 3,090 3,370 2.6 3.5 4.3 2.380 2,850 3,230 2.5 3.3 4.1 2,090 2,610 3,090 2.4 3.1 3.9 1,710 2,380 2,850 2.2 2.9 3.6 1,330 2,090 2,610 2.1 2.7 3.4 950 1,810 2,380 2.0 2.5 3.2 24 (800) 627-4499 • Fax: (608) 221-2824 OA 14" X 28" 62" 47" 12" RA EA Left View 38 7/8" 61 3/4" Top View 61 3/4" Unit OA 1" FA 12" FA EA Front View RA 35 1/4" OA 43 1/4" Service Area EA 12" x 12" 95 7/8" Service Area E-box 7/8" Dia. Wiring Entries 12" 1" 12" Right View 38 7/8" FA 12" x 12" 61 3/4" 58 1/8" 55 7/8" RA 14" X 28" Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside 8 3/4" Unit Dimensions 39 3/8" overall 8 3/4" 3 7/8" EA: OA: RA: FA: 47" 62" HE3XINV 37 1/2" www.RenewAire.com 25 HE4XINH Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 1,000-4,400 CFM AHRI 1060 Certified Core: Four L125-00 Airflow Rating Points (for AHRI): 3,000 CFM and 2,250 CFM Number Motors: Two G5 Performance HP Volts HZ Phase FLA Min. Cir. Amps Max. Fuse Size 2 208-230 208-230 460 575 60 60 60 60 Single Three Three Three 11.3-10.5 6.2-6.2 3.5 2.3 25.4 14.0 7.9 5.2 35 20 15 15 3 208-230 208-230 460 575 60 60 60 60 Sinlge Three Three Three 13.7 9.2-8.6 4.3 3.2 30.8 20.7 9.7 7.2 45 30 15 15 5 208-230 460 575 60 60 60 Three Three Three 14.0-13.0 6.5 5.0 31.5 14.6 11.3 45 20 15 CFM Effectiveness (%) 1,000 2,000 3,000 4,000 80 Control Voltage: 24 VAC Sensible Winte Filters: Eight total, MERV 8, 2” pleated, 20” x 20” nominal size r Tota 60 Sum l mer 40 Weight: 846 lbs (unit), 900 lbs (shipping weight) Shipping Dimensions: 84” W x 92” L x 46” H Tota l *At AHRI 1060 standard conditions (See certified data on page 67 for core components.) Airflow Performance External Static Pressure (Inches Water Column) Motor HP Blower RPM Nominal Turns Open 0.0 CFM 0.25 BHP CFM 0.5 BHP CFM 0.75 BHP CFM 1.0 BHP CFM 1.25 BHP CFM 1.5 BHP CFM BHP 2 1,010 1,210 1,370 4.5 2 0 2,489 2,995 - 0.9 1.6 - 2,200 2,290 - 0.9 1.5 - 1,715 2,430 - 0.8 1.4 - 1,100 2,005 2,600 0.7 1.3 2.0 1,540 2,215 1.2 1.9 1,800 1.7 1,100 1.5 3 1,345 1,535 1,685 4.5 2 0 3,295 3,832 - 2.1 2.9 - 3,145 3,682 - 2.1 2.9 - 2,840 3,480 - 2.0 2.8 - 2,509 3,170 - 1.9 2.6 - 2,116 2,839 3,409 1.8 2.4 3.0 1,747 2,449 3,003 1.6 2.3 2.8 1,135 1,878 2,465 1.5 2.0 2.4 5 1,495 1,675 1,855 6 3 0 3,718 4,223 - 2.7 3.8 - 3,568 4,083 - 2.6 3.7 - 3,345 3,943 - 2.6 3.6 - 3,030 3,659 4,287 2.4 3.4 4.9 2,686 3,364 4,011 2.2 3.2 4.6 2,301 2,994 3,760 2.1 2.9 4.3 1,722 2,490 3,434 1.9 2.7 4.0 26 (800) 627-4499 • Fax: (608) 221-2824 5 1/2" 22 3/8" 40 3/8" 39" FA EA Left View 82" Unit Dimensions E-box 12" x 32" typ E-box FA EA 74 7/8" Control Wiring Inlet 77 7/8" Power Wiring Inlet 18 5/8" Front View 57 1/4" Top View 64 1/2" Service Area 64 1/2" overall 82" RA OA RA OA 4 1/4" OA 12" X 40" Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside Right View RA 12" X 40" 82" EA: OA: RA: FA: 40 3/8" HE4XINh 5 1/8" 25 1/2" www.RenewAire.com 27 116 3/4" Service Area HE4XINV Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 1,000-4,400 CFM AHRI 1060 Certified Core: Four L125-00 Airflow Rating Points (for AHRI): 3,000 CFM and 2,250 CFM Number Motors: Two G5 Performance HP Volts HZ Phase FLA Min. Cir. Amps Max. Fuse Size 2 208-230 208-230 460 575 60 60 60 60 Single Three Three Three 11.3-10.5 6.2-6.2 3.5 2.3 25.4 14.0 7.9 5.2 35 20 15 15 3 208-230 208-230 460 575 60 60 60 60 Sinlge Three Three Three 13.7 9.2-8.6 4.3 3.2 30.8 20.7 9.7 7.2 45 30 15 15 5 208-230 460 575 60 60 60 Three Three Three 14.0-13.0 6.5 5.0 31.5 14.6 11.3 45 20 15 CFM Effectiveness (%) 1,000 2,000 3,000 4,000 80 Control Voltage: 24 VAC Sensible Winte Filters: Eight total, MERV 8, 2” pleated, 20” x 20” nominal size r Tota 60 Sum l mer 40 Weight: 815 lbs (unit), 875 lbs (shipping weight) Shipping Dimensions: 45” W x 90” L x 70” H Tota l *At AHRI 1060 standard conditions (See certified data on page 67 for core components.) Airflow Performance External Static Pressure (Inches Water Column) Motor HP Blower RPM Nominal Turns Open 0.0 CFM 0.25 BHP CFM 0.5 BHP CFM 0.75 BHP CFM 1.0 BHP CFM 1.25 BHP CFM 1.5 BHP CFM BHP 2 1,010 1,210 1,370 4.5 2 0 2,300 2,800 3,068 0.9 1.5 2.2 1,810 2,350 2,754 0.8 1.4 2.0 1,300 1,950 2,430 0.7 1.3 1.9 1,500 2,082 1.3 1.8 1,050 1,725 1.2 1.7 1,342 1.6 - - 3 1,345 1,535 1,685 4.5 2 0 3,042 3,452 - 2.0 2.7 - 2,705 3,226 - 1.9 2.6 - 2,341 2,955 - 1.8 2.5 - 1,983 2,696 3,148 1.7 2.3 2.9 1,611 2,422 2,884 1.6 2.2 2.8 1,211 2,093 2,595 1.5 2.0 2.6 1,722 2,269 1.9 2.4 5 1,495 1,675 1,855 6 3 0 3,348 3,896 - 2.7 3.9 - 3,114 3,688 - 2.6 3.7 - 2,820 3,466 4,229 2.4 3.6 4.9 2,549 3,232 3,979 2.3 3.4 4.6 2,268 2,972 3,700 2.2 3.2 4.3 1,917 2,694 3,430 2.1 3.0 4.0 1,523 2,392 3,178 1.9 2.8 3.8 28 (800) 627-4499 • Fax: (608) 221-2824 62" 14" X 34" 47" 8 1/2" RA FA 81 1/2" Unit EA 12" X 32" EA Left View OA 81 3/8" 38 7/8" 1" Top View OA 115 1/2" Service Area Unit Dimensions 39 3/8" with flanges 3 7/8" EA OA Front View 35 1/4" FA RA E-box 12" X 32" Right View FA RA 81 3/8" 75 1/2" 38 3/4" 1" 14" X 34" Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside 7/8" Dia. Wiring Entries EA: OA: RA: FA: 8 1/2" 47" 62 1/4" HE4XINV 37 1/2" www.RenewAire.com 29 HE6XIN Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 1,500-6,500 CFM AHRI 1060 Certified Core: Six L125-00 Airflow Rating Points (for AHRI): 4,500 CFM and 3,375 CFM Number Motors: Two G5 Performance Effectiveness (%) Volts HZ Phase FLA Min. Cir. Amps Max. Fuse Size 5 208-230 460 575 60 60 60 Three Three Three 14.2-13.0 6.5 5.0 32.6 14.9 11.3 45 20 15 7.5 208-230 460 575 60 60 60 Three Three Three 20.9-19.2 9.6 7.6 47.0 21.6 17.1 70 30 25 Control Voltage: 24 VAC CFM 3,000 HP 4,000 5,000 Filters: Twelve total, MERV 8, 2” pleated, 20” x 20” nominal size 6,000 Weight: 2,340 lbs (unit), 2,640 lbs (shipping weight) 80 Shipping Dimensions: 85” W x 114” L x 85” H Sensible Winter 60 Total Summ er To tal 40 *At AHRI 1060 standard conditions (See certified data on page 67 for core components.) Airflow Performance External Static Pressure (Inches Water Column) Motor HP Blower RPM Nominal Turns Open 0.0 CFM 0.25 BHP CFM 0.5 BHP CFM 0.75 BHP CFM 1.0 BHP CFM 1.25 BHP CFM 1.5 BHP CFM BHP 5 1,460 1,610 1,725 4.5 2 0 5,005 5,550 - 3.2 4.2 - 4,800 5,375 - 3.2 4.2 - 4,650 5,250 - 3.1 4.1 - 4,475 5,100 5,525 3.0 4.1 5.0 4,200 4,900 5,475 2.9 4.0 5.0 4,000 4,650 5,200 2.8 3.9 4.9 3,750 4,500 5,050 2.8 3.8 4.8 7.5 1,560 1,740 1,865 4.5 2 0 5,275 5,950 6,500 3.7 5.0 6.5 5,200 5,825 6,350 3.6 5.0 6.5 4,900 5,625 6,225 3.5 4.9 6.4 4,775 5,490 6,125 3.5 4.9 6.4 4,550 5,325 5,910 3.4 4.8 6.3 4,350 5,125 5,825 3.3 4.7 6.2 4,125 4,950 5,625 3.3 4.7 6.1 30 (800) 627-4499 • Fax: (608) 221-2824 62" RIGHT VIEW 108 1/2" Base EA RA BACK VIEW 9 1/2" 49" OA 24" typ 78 1/4" Overall Core Access INDOOR UNITS: EA BLOWER Outlet is 18" x 24". 24" x 36" Duct Flange is also supplied. Field install only in location shown. Power and Control Wiring Entries 7/8" Dia. Unit Dimensions 55" 36" 151 1/2" Service Area 34" Service Area HE6XIN 36" 22" www.RenewAire.com 31 LEFT VIEW 62" 18" 108 1/2" Base FA 112 3/4" Unit Roof TOP VIEW EA 148 1/4" Service Area 24" 77" 4" 9" Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside 39 1/2" Min. Clearance FRONT VIEW 85 1/2" Unit Roof FA BLOWER Outlet is 18" x 24". 24" x 36" Duct Flange is also supplied. Field install only in location shown. Front Views at 0.5X: BLOWER ROTATION Power and Control Wiring Entries EA: OA: RA: FA: HE8XIN Indoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 2,000-8,000 CFM AHRI 1060 Certified Core: Eight L125-00 Airflow Rating Points (for AHRI): 6,000 CFM and 4,500 CFM Number Motors: Two Effectiveness (%) 2,000 4,000 6,000 Max. Fuse Size Three 14.2-13.0 Three 6.5 5.0 Three 32.6 14.9 11.3 45 20 15 60 60 60 Three 20.9-19.2 Three 9.6 Three 7.6 47.0 21.6 17.1 70 30 25 60 60 60 Three 29.0-26.8 Three 13.4 Three 10.0 65.3 30.2 22.5 90 45 35 Volts HZ Phase 5 208-230 460 575 60 60 60 7.5 208-230 460 575 10 208-230 460 575 G5 Performance CFM Min. Cir. Amps HP 8,000 FLA Control Voltage: 24 VAC 80 Filters: Sixteen total, MERV 8, 2” pleated, 20” x 20” nominal size Sensible Winte Weight: 2,525 lbs (unit), 2,825 lbs (shipping weight) r Tota 60 l Summ Shipping Dimensions: 85” W x 114” L x 85” H er To tal 40 *At AHRI 1060 standard conditions (See certified data on page 67 for core components.) Airflow Performance External Static Pressure (Inches Water Column) Motor HP Blower RPM Nominal Turns Open 0.0 CFM 0.25 BHP CFM 0.5 BHP CFM 0.75 BHP CFM 1.0 BHP CFM 1.25 BHP CFM 1.5 BHP CFM BHP 5 1,460 1,610 1,725 4.5 2 0.5 5,575 6,200 6,550 3.2 4.3 5.0 5,425 6,010 6,380 3.2 4.3 5.0 5,200 5,875 6,210 3.2 4.2 5.0 5,000 5,700 6,100 3.2 4.2 5.0 4,775 5,500 5,880 3.1 4.2 4.9 4,550 5,325 5,730 3.0 4.1 4.8 4,270 5,125 5,510 2.9 4.1 4.8 7.5 1,560 1,740 1,865 4.5 2 0 6,000 6,700 - 3.9 5.3 - 5,850 6,575 - 3.9 5.3 - 5,650 6,400 - 3.8 5.3 - 5,475 6,300 6,800 3.8 5.3 7.5 5,275 6,125 6,675 3.8 5.3 7.5 5,100 5,950 6,500 3.7 5.2 7.5 4,875 5,750 6,375 3.7 5.2 7.4 10 1,810 2,020 2,105 4.5 2 1 7,000 7,850 - 6.1 8.5 - 6,875 7,745 - 6.1 8.5 - 6,750 7,625 7,950 6.1 8.5 9.6 6,600 7,450 7,800 6.0 8.4 9.6 6,425 7,350 7,725 6.0 8.4 9.6 6,275 7,200 7,600 6.0 8.3 9.5 6,100 7,050 7,450 5.9 8.3 9.5 32 (800) 627-4499 • Fax: (608) 221-2824 62" RIGHT VIEW 108 1/2" Base EA RA BACK VIEW 9 1/2" 49" OA 24" typ 78 1/4" Overall Core Access INDOOR UNITS: EA BLOWER Outlet is 18" x 24". 24" x 36" Duct Flange is also supplied. Field install only in location shown. Power and Control Wiring Entries 7/8" Dia. Unit Dimensions 55" 36" 151 1/2" Service Area 34" Service Area HE8XIN 36" 22" www.RenewAire.com 33 LEFT VIEW 62" 18" 108 1/2" Base FA 112 3/4" Unit Roof TOP VIEW EA 148 1/4" Service Area 24" 77" 4" 9" Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside 39 1/2" Min. Clearance FRONT VIEW 85 1/2" Unit Roof FA BLOWER Outlet is 18" x 24". 24" x 36" Duct Flange is also supplied. Field install only in location shown. Front Views at 0.5X: BLOWER ROTATION Power and Control Wiring Entries EA: OA: RA: FA: Commercial OutDOOR Products • Many airflow orientation options. • Weatherized cabinets with hoods for outdoor applications. • Wide range of airflow and static capacities. • Easy installation and service. • AHRI certified performance data for efficiency and cross leakage. • UL tested flammability and smoke generation that meets NFPA 90A and 90B test standards for commercial applications. • Ten year core warranty. RenewAire means Trouble-Free ERV. EA: OA: RA: FA: Contact RenewAire for other application schematics. 34 (800) 627-4499 • Fax: (608) 221-2824 Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside Packaged Rooftop Energy Recovery Ventilators: EV450RT, HE1XRT, HE2XRT, HE3XRT, HE4XRT, HE6XRT & HE8XRT Part I - General A. Product Specification 1.Energy Recovery Ventilator (ERV) shall be a packaged unit as manufactured by RenewAire and shall transfer both heat and humidity using static plate core technology. B. Quality Assurance 1.The energy recovery cores used in these products shall be third party Certified by AHRI under its Standard 1060 for Energy Recovery Ventilators. AHRI published certifications shall confirm manufacture’s published performance for airflow, static pressure, temperature and total effectiveness, purge air (OACF) and exhaust air leakage (EATR). Products that are not currently AHRI Certified will not be accepted. 2. No condensate drain pans or drains shall be allowed and unit shall be capable of operating in both winter and summer conditions without generating condensate. 3. The unit case shall be constructed of G90 galvanized, 20-gauge steel, with lapped corners and zinc plated screw fasteners. The unit roof shall be one piece or have watertight standing seam joints and shall overlap wall panels and doors in order to positively shed water. 4. Access doors shall provide easy access to blowers, ERV cores and filters. Doors shall have an airtight compression seal using closed cell foam gaskets rated for outdoor exposure. 5. Weatherhoods shall be screened to exclude birds and animals. Inlet weatherhoods shall be sized to maintain inlet velocities below 500 fpm, and equipped with rain excluder baffles. 2. Manufacturer shall be able to provide evidence of independent testing of the core by Underwriters Laboratory (UL), verifying a maximum flame spread index (FSI) of 25 and a maximum smoke developed index (SDI) of 50 thereby meeting NFPA 90A and NFPA 90B requirements for materials in a compartment handling air intended for circulation through a duct system. The method of test shall be UL Standard 723. 6. Case walls and doors shall be insulated with 1 inch, 4 pound density, foil/ scrim faced, high-density fiberglass board insulation, providing a cleanable surface and eliminating the possibility of exposing the fresh air to glass fibers. 3. Unit shall be Listed under UL 1812 Standard for Ducted Air to Air Heat Exchangers (Note that a few low volume product or product configurations are not UL Listed). Units intended for “Outdoor Use” shall be listed using the specific UL requirements for rain penetration, corrosion protection and seal durability and shall be so labeled. 8. Unit shall have single-point power connection and a single-point 24 VAC contactor control connection (Except Inverter Ready units that have terminal connections for an independent inverter for each airstream). 4. The ERV core shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of ten years from the date of purchase. The balance-of-unit shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of two years from the date of purchase. Part II – Performance A. Energy Transfer The ERV shall be capable of transferring both sensible and latent energy between airstreams. Latent energy transfer shall be accomplished by direct water vapor transfer from one airstream to the other, without exposing transfer media in succeeding cycles directly to the exhaust air and then to the fresh air. B. Passive Frost Control 7. The ERV cores shall be protected by a MERV-8 rated, 2” nominal, pleated, disposable filter in both airstreams. 9. Blower motors shall be EPACT compliant for energy efficiency and be thermally protected or supplied with external starters. 10. Blowers shall be quiet running, forward curve type and be either direct drive or belt drive. HE6X and HE8X units use backward incline, belt drive blower packages. Belt drive motors shall be provided with adjustable pulleys and motor mounts allowing for proper belt tensioning. B. Options (Select options based on application requirements) 1. Provide unit and duct connection orientation per project schedule. 2. Provide double wall construction with 24-gauge galvanized steel liner. 3. Units are available single or three phase at a full range of operating voltages. See project schedule. 4. Provide motor horsepower as specified in project schedule. The ERV core shall perform without condensing or frosting under normal operating conditions (defined as outside temperatures above -10°F and inside relative humidity below 40%). Occasional more extreme conditions shall not affect the usual function, performance or durability of the core. No condensate drains will be allowed. 5. Provide “inverter-ready” units which include shielded power wiring and terminal connections for inverters (inverters provided and installed by others). C. Continuous Ventilation 7. Provide factory installed non-fused disconnects. Unit shall have the capacity to operate continuously without the need for bypass, recirculation, pre-heaters or defrost cycles under normal operating conditions. D. Positive Airstream Separation Water vapor transfer shall be through molecular transport by hydroscopic resin and shall not be accomplished by “porous plate” mechanisms. Exhaust and fresh airstreams shall travel at all times in separate passages, and airstreams shall not mix. E. Laminar Flow Airflow through the ERV core shall be laminar over the products entire operating airflow range, avoiding deposition of particulates on the interior of the energy exchange plate material. Part III – Product 6. Provide factory installed fused disconnects. 8. Provide factory installed transformer/relay package to supply a 24VAC power source. 9. Provide factory installed filter monitors for each airstream. 10. Provide 14 inch high, non-pitched roof curbs as available from the factory. Pitched curbs, vibration curbs, seismic curbs and other custom curbs are available directly from curb manufacturer. 11. RTC (RoofTop Connect) units shall have return air and fresh air ducts configured to permit direct tie-in to rooftop air handlers using factory offered transition piece. (See separate specification for factory transition availability.) 12. Provide high wind tie-down kit. A. Construction 1. The energy recovery component shall be of fixed-plate cross-flow construction, with no moving parts. 35 www.RenewAire.com EV450RT Outdoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 240-550 CFM AHRI 1060 Certified Core: One L85 Airflow Rating Points (for AHRI): 450 CFM and 338 CFM Motors: One, 0.6 hp (Single Phase) One, 0.5 hp (Three Phase) G5 Performance Airflow CFM ESP in H 20 Watts 1P 3P Temp EFF% Total EFF% Winter/Summer* 240 1.00 425 243 80 75/66 338 0.85 474 313 77 71/61 380 0.75 496 345 75 69/59 450 0.50 534 412 73 66/56 500 0.25 563 461 71 64/54 550 0.00 593 516 70 62/52 600 -0.25 623 572 68 60/50 V HZ Phase FLA 115 60 Single 7.0 208-230 60 Single 3.5 277 60 Single 2.4 208-230 60 Three 1.7-1.5 460 60 Three 0.8 Control Voltage: 24 VAC Filters: Two total, MERV 8, 2” pleated, 14” x 20” nominal size Weight: 185 lbs (unit), 235 lbs (shipping weight) Shipping Dimensions: 48” W x 90” L x 25” H (on pallet) *At AHRI 1060 standard conditions (See certified data on page 67 for core components.) Dimensions 8 3/4 5 1/2 13 1/8 RA 10 1/4 4 1/2 2 3/4 2 5/8 11 3/4 FA EA OA TOP VIEW WITH DOOR OFF EBOX PWR AND CONTROL WIRING DRILL HERE OR THRU BOTTOM FILTERS 37 1/2 2 7/8 3 1/8 4 3/4 19 1/4 OA EA LEFT VIEW 33 7/8 RIGHT VIEW 3 1/8 1 1 4 3/8 12 3/8 FA FRONT VIEW 47 7/8 74 7/8 36 (800) 627-4499 • Fax: (608) 221-2824 RA EV450RT Application options Standard Roof Curb Shown (available option). Curbs for sloped roofs or metal roofing are available on a custom basis from RenewAire or from local curb fabricators. For horizontal connection of either the Fresh Air duct or the Return Air duct, stack the optional RTF/RTR Adapter on the Standard Roof Curb. Duct openings to be field cut into adapter. Opening location and size is flexible. The RTH/RTC Adapter allows horizontal connection of both the Fresh Air and the Return Air ducts. It is also possible to connect the adapter directly to the return plenum of most Rooftop Units (openings must be cut into RTU). Duct openings to be field cut into adapter. Opening location and size is flexible. EA: OA: RA: FA: Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside 37 www.RenewAire.com HE1XRT Outdoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 250-870 CFM AHRI 1060 Certified Core: One L125-00 Airflow Rating Points (for AHRI): 750 CFM and 560 CFM Number Motors: Two V HZ Phase FLA Min. Cir. Amps Max. Fuse Size 115 60 Single 8.6 19.4 25 208-230 60 Single 4.3 9.7 15 277 60 Single 2.4 5.4 15 208-230 60 Three 2.1 5.2 15 460 60 Three 1.1 2.6 15 G5 Performance CFM Effectiveness (%) 250 500 Control Voltage: 24 VAC 750 1,000 Filters: Two total, MERV 8, 2” pleated, 20” x 20” nominal size Weight: 250 lbs (unit), 330 lbs (shipping weight) 80 Sensible Winter 60 Summ Total er To Shipping Dimensions: 31” W x 76” L x 45” H Options: Controls (see pages 64 & 65) Roof curb Alternate duct connections tal 40 *At AHRI 1060 standard conditions (See certified data on page 67 for core components.) Base Type/Airflow Orientations RTV RTF EA OA RTR EA OA OA EA FA FA FA OA RA RA RA FA RA RTH EA Airflow Performance Motor HP Phase External Static Pressure (Inches Water Column) 0.0 0.25 0.5 0.75 1.0 1.25 1.5 0.75 (Two DD) Single Phase 950 CFM 1,630 Watts 880 CFM 1,550 Watts 820 CFM 1,475 Watts 775 CFM 1,430 Watts 730 CFM 1,385 Watts 650 CFM 1,300 Watts 540 CFM 1,200 Watts 0.75 (Two DD) Three Phase 950 CFM 1,200 Watts 880 CFM 1,100 Watts 820 CFM 1,020 Watts 760 CFM 980 Watts 660 CFM 890 Watts 560 CFM 800 Watts 450 CFM 700 Watts 38 (800) 627-4499 • Fax: (608) 221-2824 www.RenewAire.com 39 4 7/8" LEFT VIEW EA 9" 3" 10 3/8" 17 3/8" Control 19 1/4" Power RTH, RTR ONLY 4" Power Wiring Inlet 7/8" Dia. Control Wiring Inlet 7/8" Dia. FA FA (RTH,RTR) 12" x 12" 22 1/2" 56 1/8" 40 1/4" Unit Dimensions HE1XRT RTV, RTF ONLY FA FRONT VIEW TOP VIEW Service Area RA 63 7/8" 55" 44 1/4" 29 1/2" 14 3/4" RTV, RTR ONLY RA OA RA (RTH,RTF) 12" x 12" RTH, RTF ONLY OA RA (RTV,RTR) 12" x 12" FA (RTV,RTF) 12" x 12" RIGHT VIEW 4 3/8" 4 7/8" EA: OA: RA: FA: CURB1X Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside HE1XRTC Outdoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 500-1,000 CFM AHRI 1060 Certified Core: One L125-00 Airflow Rating Points (for AHRI): 750 CFM and 560 CFM Number Motors: Two G5 Performance CFM Effectiveness (%) 300 500 V HZ Phase FLA Min. Cir. Amps Max. Fuse Size 115 60 Single 8.6 19.4 25 208-230 60 Single 4.3 9.7 15 277 60 Single 2.4 5.4 15 208-230 60 Three 2.1 5.2 15 460 60 Three 1.1 2.6 15 Control Voltage: 24 VAC 700 900 Filters: Two total, MERV 8, 2” pleated, 20” x 20” nominal size Weight: 300 lbs (unit), 375 lbs (shipping weight) 80 Shipping Dimensions: 40” W x 87” L x 45” H Sensible Winte r Tota 60 Summ l er Tot al 40 *At AHRI 1060 standard conditions (See certified data on page 67 for core components). Airflow Performance Damper Position Static Pressure in Adjacent Air Handler (Inches Water Column) Total Watts -0.5 1 Phase 3 Phase -0.25 0.0 FA EA +0.25 FA EA +0.5 EA FA EA 1,035 900 985 950 940 985 FA 885 1,045 EA FA 835 100% Open 1,295 1,155 855 65% Open 1,285 1,140 785 980 820 945 855 900 890 855 935 810 55% Open 1,275 1,130 775 965 805 920 840 875 865 835 900 790 45% Open 1,265 1,120 750 920 775 875 805 935 830 790 860 750 35% Open 1,265 1,110 695 860 730 820 760 775 790 740 820 700 25% Open 1,265 1,100 625 780 660 750 685 715 715 680 750 650 15% Open 1,260 1,085 575 585 615 630 650 665 685 705 730 745 40 (800) 627-4499 • Fax: (608) 221-2824 LEFT VIEW EA 9" OA OA 21 1/8" OA Access to Electrical Components, OA filter Access to blowers 22 1/2" 56 1/8" Control Wire In 7/8" Dia. Power Wire In 7/8" Dia. Unit Dimensions 40 1/4" FRONT VIEW Shown with Leveling Legs (shipped loose) 51" Service Area EA 46 3/8" Lifting Lugs 72" 9" HE1XRTC RIGHT VIEW RA FA TOP VIEW FA RA 19 7/8" Lifting Lugs RA FA 16" 14 1/2" to 17 1/2" height adjustment 3 1/2" Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside 6 5/8" EA: OA: RA: FA: 11" 11" www.RenewAire.com 41 HE2XRT Outdoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 500-2,000 CFM AHRI 1060 Certified Core: Two L125-00 Airflow Rating Points (for AHRI): 1,500 CFM and 1,120 CFM Number Motors: Direct Drive (DD) Four, Belt Drive (BD) Two Drive HP Volts HZ Phase FLA Min. Cir. Amps Max. Fuse Size DD 0.75 115 208-230 277 208-230 460 60 60 60 60 60 Single Single Single Three Three 8.6 4.3 2.4 2.1 1.1 36.6 18.3 10.2 9.8 4.9 45 20 15 15 15 BD 1.5 208-230 208-230 460 575 60 60 60 60 Single Three Three Three 9.3-9.0 4.8-4.8 2.4 1.8 20.9 10.8 5.4 4.1 30 15 15 15 BD 2 208-230 208-230 460 575 60 60 60 60 Single Three Three Three 11.3-10.5 6.2-6.2 3.1 2.3 25.4 14.0 7.0 5.2 35 20 15 15 G5 Performance CFM Effectiveness (%) 500 1,000 1,500 2,000 80 Sensible Winte 60 Control Voltage: 24 VAC r Tota Summ l Filters: Four total, MERV 8, 2” pleated, 20” x 20” nominal size er To tal Weight: 488 lbs (unit), 525 lbs (shipping weight) 40 Shipping Dimensions: 51” W x 76” L x 45” H *At AHRI 1060 standard conditions (See certified data on page 67 for core components). Base Type/Airflow Orientations RTV RTF EA OA RTR EA RA OA EA FA OA RA FA FA RA RA FA RTH EA OA Airflow Performance External Static Pressure (Inches Water Column) Motor HP Blower RPM Nominal Turns Open 0.0 0.25 0.5 0.75 1.0 1.25 0.75 (Four DD) Single Phase N/A N/A N/A N/A 1,770 CFM 2,220 Watts 1,680 CFM 2,145 Watts 1,555 CFM 2,015 Watts 1,375 CFM 1,825 Watts 1,110 CFM 1,560 Watts 760 CFM 1,195 Watts 0.75 (Four DD) Three Phase N/A N/A N/A N/A 1,760 CFM 2,300 Watts 1,670 CFM 2,200 Watts 1,550 CFM 2,050 Watts 1,375 CFM 1,825 Watts 1,120 CFM 1,530 Watts 850 CFM 1,375 Watts CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 1.5 (BD) 1,000 1,230 1,420 4.5 2 0 1,378 1,694 1,956 0.5 0.9 1.4 1,175 1,550 1,850 0.5 0.9 1.4 900 1,335 1,680 0.4 0.8 1.2 635 1,125 1,475 0.4 0.7 1.2 1,000 1,300 0.7 1.1 500 1,200 0.6 1.1 930 0.9 2 (BD) 1,220 1,470 1,660 4.5 2 0 1,681 2,025 - 0.9 1.6 - 1,530 1,925 - 0.9 1.5 - 1,315 1,750 2,000 0.7 1.4 2.0 1,100 1,575 1,900 0.7 1.3 1.9 975 1,375 1,750 0.6 1.2 1.8 430 1,275 1,570 0.6 1.2 1.7 1,125 1,475 1.1 1.7 Note: Brake Horse Power (BHP) is for one blower motor package only. 42 (800) 627-4499 • Fax: (608) 221-2824 1.5 - - 500 CFM 950 Watts www.RenewAire.com 43 7 1/4" 76 1/8" LEFT VIEW EA 4" Wiring Inlet 42 1/4" RTH, RTR ONLY EA 25 1/2" Curb Center RTV, RTF ONLY FA Service Area 15 3/4" Power Wiring Inlet 7/8" Dia. Control Wiring Inlet 7/8" Dia. FA 3 3/4" 37 3/8" power 10 5/8" 34 7/8" control FA (RTV, RTF) 10" X 24" FA (RTH, RTR) 14" X 24" 4 5/8" 51 1/8" RTV, RTR ONLY RA 72 3/8" RTH, RTF ONLY FRONT VIEW RA OA TOP VIEW 15 3/4" OA RA (RTV RTR) 10" X 24" 20 1/8" Curb Center Unit Dimensions 3" Top of Curb HE2XRT 40 1/4" 43 1/4" RA (RTH, RTF) 14" X 24" RIGHT VIEW 39 3/8" EA: OA: RA: FA: CURB2X Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside HE2XRTC Outdoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 1,000-1,700 CFM AHRI 1060 Certified Core: Two L125-00 Airflow Rating Points (for AHRI): 1,500 CFM and 1,120 CFM Number Motors: Two, Belt Drive G5 Performance Max. Fuse Size Single 11.3-10.5 25.4 35 Three Three Three 14.0 7.0 5.2 20 15 15 Volts HZ Phase BD 2 208-230 60 BD 2 208-230 460 575 60 60 60 FLA 6.2-6.2 3.1 2.3 Control Voltage: 24 VAC CFM 500 Min. Cir. Amps HP 1,000 Filters: Four total, MERV 8, 2” pleated, two 20” x 20” nominal size, 1,500 and two 14” x 20” nominal size 2,000 Effectiveness (%) Weight: 538 lbs (unit), 575 lbs (shipping weight) 80 Shipping Dimensions: 51” W x 76” L x 45” H Sensible Winte 60 r Tota Summ l er To tal 40 *At AHRI 1060 standard conditions (See certified data on page 67 for core components). Airflow Performance Static Pressure in Adjacent Air Handler (Inches Water Column) Blower RPM Nominal Turns Open 1,420 0 1,700 1.8 1,850 1.9 - 1,360 1 1,540 1.7 1,720 1.8 1,860 1.9 1,920 2.0 1,980 2.0 1,300 2 1,375 1.5 1,600 1.7 1,740 1.8 1,800 1.8 1,860 1.9 1,240 3 1,240 1.4 1,440 1.6 1,625 1.7 1,690 1.7 1,740 1.7 1,180 4 1,080 1.3 1,300 1.4 1,500 1.5 1,575 1.6 1,640 1.6 1,675 0 - - 1,630 2.0 1,575 2.0 1,465 1.9 1,595 1 1,720 2.0 1,620 2.0 1,530 1.9 1,440 1.8 1,355 1.7 1,515 2 1,630 1.9 1,520 1.8 1,430 1.8 1,355 1.7 1,230 1.6 1,435 3 1,530 1.8 1,430 1.7 1,320 1.7 1,250 1.6 1,135 1.5 4 1,415 1.6 1,310 1.6 1,225 1.5 1,150 1.5 1,035 1.4 -0.5 CFM Exhaust Air Fresh Air 1,355 -0.25 BHP CFM - - 0.0 BHP CFM 44 (800) 627-4499 • Fax: (608) 221-2824 +0.25 BHP CFM - - +0.5 BHP CFM - - BHP - www.RenewAire.com 45 39 1/4" RA FA BACK VIEW OA 75 1/8" 57 3/4" OA 101" Service Area EA RA FA FRONT VIEW 59" C-C 75 1/8" 57 3/4" shown with leveling legs (shipped loose) Control Wiring In 7/8" Dia. EA 60 3/8" 42 3/8" 40 1/8" 52 3/4" Lifting Lugs each corner 76" 4 1/2" TOP VIEW and service area RA 39 1/4" 37 1/4" Lifting Lugs LEFT VIEW Power Wiring In 7/8" Dia. EA Filter Access EA FA 39 1/4" OA 21 3/4" 11 1/8" typ Unit Dimensions 39 1/4" 37 1/4" 32" EA: OA: RA: FA: 7 1/8" HE2XRTC RIGHT VIEW 7 3/4" to 10 1/2" height adjustment RA FA 42 1/4" 29" Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside 1 7/8" HE3XRT Outdoor Unit Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 750-3,000 CFM AHRI 1060 Certified Core: Three L125-00 Airflow Rating Points (for AHRI): 2,250 CFM and 1,690 CFM Number Motors: Two HP Volts HZ Phase FLA Min. Cir. Amps Max. Fuse Size 2 208-230 208-230 460 575 60 60 60 60 Single Three Three Three 11.3-10.5 6.2-6.2 3.1 2.3 25.4 14.0 7.0 5.2 35 20 15 15 3 208-230 208-230 460 575 60 60 60 60 Single Three Three Three 13.7 9.2-8.6 4.3 3.2 30.8 20.7 9.7 7.2 45 30 15 15 5 208-230 460 575 60 60 60 Three Three Three 14.0-13.0 6.5 5.0 31.5 14.6 11.3 45 20 15 G5 Performance CFM Effectiveness (%) 1,500 2,000 2,500 3,000 80 Control Voltage: 24 VAC Sensible Winter 60 Filters: Six total, MERV 8, 2” pleated, 20” x 20” nominal size Total Summ Weight: 726 lbs (unit), 755 lbs (shipping weight) Shipping Dimensions: 72” W x 84” L x 49” H er To tal 40 *At AHRI 1060 standard conditions (See certified data on page 67 for core components). Base Type/Airflow Orientations RTV RTF EA OA RTR EA RA OA EA FA OA RA FA FA RA RA FA RTH EA OA Airflow Performance External Static Pressure (Inches Water Column) Motor HP Blower RPM Nominal Turns Open 0.0 CFM 0.25 BHP CFM 0.5 BHP CFM 0.75 BHP CFM 1.0 BHP CFM 1.25 BHP CFM 1.5 BHP CFM BHP 2 1,095 1,220 1,340 4 2 0 2,040 2,340 2,590 1.3 1.5 1.8 1,760 2,110 2,370 1.3 1.4 1.7 1,370 1,790 2,130 1.2 1.3 1.6 920 1,380 1,760 1.1 1.2 1.4 940 1,310 1.2 1.3 980 1.2 - - 3 1,345 1,535 1,685 4.5 2 0 2,420 2,850 - 2.3 2.8 - 2,280 2,760 - 2.2 2.7 - 2,090 2,570 - 2.1 2.6 - 1,760 2,380 2,660 2.0 2.5 2.9 1,280 2,090 2,470 1.9 2.4 2.7 860 1,810 2,280 1.9 2.2 2.6 1,330 2,000 2.1 2.4 5 1,495 1,675 1,855 6.5 3.5 0 2,850 3,280 - 3.1 3.8 - 2,710 3,140 - 3.0 3.7 - 2.520 2,990 3,470 2.9 3.5 4.9 2,280 2,800 3,330 2.8 3.3 4.7 2,040 2,610 3,140 2.7 3.1 4.5 1,620 2,380 3,040 2.5 2.9 4.4 1,140 2,090 2,760 2.4 2.7 4.0 46 (800) 627-4499 • Fax: (608) 221-2824 40 3/8" FA Left View 38 3/4" 12" 12" X 12" FA Outlet (RTH, RTR) 5 1/2" 21 3/4" EA 55 1/8" Control Wire Inlet 58 1/8" Power Wire Inlet Wiring In 7/8" Dia. E-box EA Outlet FA (RTV, RTF Only) 12" x 12" EA 30 1/8" Curb Center FA 17 1/2" Front View 2" 57" 89 3/4" Overall 55 1/4" lift lugs RA 9" RA OA OA Inlet Right View 4 1/8" 60 1/4" 60 1/4" lift lugs 62 1/4" Overall 97" Service Area RA (RTV, RTR Only) 11" x 34" Top View 18 3/8" 64 1/2" Service Area FA 28 3/4" Curb Center RA Unit Dimensions 18 5/8" 14 3/4" 8 1/8" 4" Top of Curb HE3XRT 40 3/8" 34" X 12" RA Inlet (RTH, RTF) 5 1/8" www.RenewAire.com 47 EA: OA: RA: FA: CURB3X Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside HE3XRTC Specifications Outdoor Unit Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 1,700-2,500 CFM AHRI 1060 Certified Core: Three L125-00 Airflow Rating Points (for AHRI): 2,250 CFM and 1,690 CFM Number Motors: Two Volts HZ Phase FLA Min. Cir. Amps Max. Fuse Size 3 208-230 60 Single 13.7-13.7 30.8 45 3 208-230 460 575 60 60 60 Three Three Three 9.2-8.6 4.4 3.2 20.7 9.9 7.2 30 15 15 Control Voltage: 24 VAC G5 Performance Filters: Five total, MERV 8, 2” pleated, three 20” x 20” and two 16” x 25” nominal size CFM 1,500 Effectiveness (%) HP 2,000 2,500 3,000 Weight: 775 lbs (unit), 830 lbs (shipping weight) Shipping Dimensions: 72” W x 84” L x 50” H 80 Sensible Winter 60 Total Summ er To tal 40 *At AHRI 1060 standard conditions (See certified data on page 67 for core components). Airflow Performance Static Pressure in Adjacent Air Handler (Inches Water Column) Blower RPM Nominal Turns Open -0.5 CFM Exhaust Air Fresh Air -0.25 BHP CFM 0.0 BHP CFM +0.25 BHP CFM +0.5 BHP CFM BHP 1,520 0 - - - - - - - - - - 1,465 1 2,130 2.9 - - - - - - - - 1,405 2 2,000 2.5 2,245 2.8 2,455 3.0 - - - - 1,345 3 1,915 2.3 2,135 2.6 2,345 2.7 2,475 2.8 2,575 2.9 1,285 4 1,725 1.8 1,950 2.1 2,180 2.3 2,345 2.4 2,455 2.5 1,800 0 2,565 3.0 2,385 2.9 2,225 2.8 2,065 2.7 1,830 2.4 1,740 1 2,480 2.8 2,290 2.7 2,150 2.6 1,975 2.5 1,740 2.2 1,680 2 2,375 2.6 2,210 2.5 2,070 2.4 1,910 2.3 1,645 2.0 1,620 3 2,290 2.4 2,125 2.4 1,990 2.3 1,825 2.1 1,555 1.8 1,560 4 2,200 2.1 2,040 2.1 1,910 2.0 1,725 1.9 1,450 1.5 48 (800) 627-4499 • Fax: (608) 221-2824 www.RenewAire.com 49 45" 42"40" Back View OA Blower and Filter Access RA FA Wiring In 7/8" Dia. 74 1/2" 57" 33 1/8" OA Unit Dimensions HE3XRTC EA OA E-box Access Left View EA EA EA OA 81 1/4" 57 1/2" Top View 83 7/8" Service Area Core and EA Blower Access Front View EA Blower Access 120" Service Area OA OA Blower and Filter Access RA Filter Access RA FA 36 3/8" Service Area RA FA 6 1/2" 25 1/2" Right View RA FA 45" Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside 61 3/4" 29" 28 1/4" EA: OA: RA: FA: HE4XRT Specifications Outdoor Unit Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 1,000-4,400 CFM AHRI 1060 Certified Core: Four L125-00 Airflow Rating Points (for AHRI): 3,000 CFM and 2,250 CFM Number Motors: Two HP Volts HZ Phase FLA Min. Cir. Amps Max. Fuse Size 2 208-230 208-230 460 575 60 60 60 60 Single Three Three Three 11.3-10.5 6.2-6.2 3.5 2.3 25.4 14.0 7.9 5.2 35 20 15 15 3 208-230 208-230 460 575 60 60 60 60 Sinlge Three Three Three 13.7 9.2-8.6 4.3 3.2 30.8 20.7 9.7 7.2 45 30 15 15 5 208-230 460 575 60 60 60 Three Three Three 14.0-13.0 6.5 5.0 31.5 14.6 11.3 45 20 15 G5 Performance CFM Effectiveness (%) 1,000 2,000 3,000 4,000 80 Control Voltage: 24 VAC Sensible Winte Filters: Eight total, MERV 8, 2” pleated, 20” x 20” nominal size r Tota 60 Sum mer l Weight: 915 lbs (unit), 1,000 lbs (shipping weight) Shipping Dimensions: 84” W x 92” L x 49” H Tota l 40 *At AHRI 1060 standard conditions (See certified data on page 67 for core components). Base Type/Airflow Orientations RTV RTF EA OA RTR EA RA OA EA FA OA RA FA FA RA RA FA RTH EA OA Airflow Performance External Static Pressure (Inches Water Column) Motor HP Blower RPM Nominal Turns Open 0.0 CFM 0.25 BHP CFM 0.5 BHP CFM 0.75 BHP CFM 1.0 BHP CFM 1.25 BHP CFM 1.5 BHP CFM BHP 2 1,010 1,210 1,370 4.5 2 0 2,489 2,995 - 0.9 1.6 - 2,200 2,290 - 0.9 1.5 - 1,715 2,430 - 0.8 1.4 - 1,100 2,005 2,600 0.7 1.3 2.0 1,540 2,215 1.2 1.9 1,800 1.7 1,100 1.5 3 1,345 1,535 1,685 4.5 2 0 3,295 3,832 - 2.1 2.9 - 3,145 3,682 - 2.1 2.9 - 2,840 3,480 - 2.0 2.8 - 2,509 3,170 - 1.9 2.6 - 2,116 2,839 3,409 1.8 2.4 3.0 1,747 2,449 3.003 1.6 2.3 2.8 1,135 1,878 2,465 1.5 2.0 2.4 5 1,495 1,675 1,855 6 3 0 3,718 4,223 - 2.7 3.8 - 3,568 4,083 - 2.6 3.7 - 3,345 3,943 - 2.6 3.6 - 3,030 3,659 4,287 2.4 3.4 4.9 2,686 3,364 4,011 2.2 3.2 4.6 2,301 2,994 3,760 2.1 2.9 4.3 1,722 2,490 3,434 1.9 2.7 4.0 50 (800) 627-4499 • Fax: (608) 221-2824 5 1/2" 40 3/8" Left View 38 3/4" 12" X 32" FA Outlet (RTH, RTR) 21 3/4" EA 74 3/4" Control Wire Inlet 77 3/4" Power Wire Inlet Wiring In 7/8" Dia. E-box FA 17 3/4" 40 1/8" Curb Center 12" X 32" FA (RTV, RTF) EA Outlet 18 5/8" 28 3/4" Curb Center Front View 2" 57" 89 3/4" Overall 55 1/4" lift lugs 9" RA OA OA Inlet Right View 80" 82" Overall 79 3/4" lifting lugs 82 1/4" Unit 117 1/4" Service Area RA (RTV, RTR Only) 11" x 46" Top View 18 5/8" 64 1/2" Service Area FA Unit Dimensions RA 12 1/4" 14 3/4" 4" Top of Curb HE4XRT 4" 40 3/8" 12" X 40" RA Inlet (RTH, RTF) 5 1/8" www.RenewAire.com 51 EA: OA: RA: FA: CURB4X Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside HE4XRTC Specifications Outdoor Unit Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 2,500-3,700 CFM AHRI 1060 Certified Core: Four L125-00 Airflow Rating Points (for AHRI): 3,000 CFM and 2,250 CFM Number Motors: Two HP Volts HZ Phase FLA 5 208-230 460 575 60 60 60 Three 14.0-13.0 Three 6.5 5.0 Three Min. Cir. Amps Max. Fuse Size 31.5 14.6 11.3 45 20 15 Control Voltage: 24 VAC Filters: Six total, MERV 8, 2” pleated, four 20” x 20”, and two 16” x 25” nominal size G5 Performance CFM Effectiveness (%) 1,000 2,000 Weight: 965 lbs (unit), 1,050 lbs (shipping weight) 3,000 4,000 Shipping Dimensions: 84” W x 92” L x 50” H 80 Sensible Winte r Tota l Sum mer Tota l 60 40 *At AHRI 1060 standard conditions (See certified data on page 67 for core components). Airflow Performance Blower RPM Nominal Exhaust Air Fresh Air Static Pressure in Adjacent Air Handler (Inches Water Column) Turns Open -0.5 CFM -0.25 BHP CFM 0.0 BHP CFM +0.25 BHP CFM +0.5 BHP CFM BHP 1,600 0 3,700 3.6 4,000 3.8 4,250 4.3 - - - - 1,555 1 3.575 3.5 3.900 3.6 4,220 3.9 4,325 4.3 4,380 4.6 1,515 2 3,415 3.2 3,740 3.5 4,135 3.8 4,275 4.2 4,340 4.5 1,470 3 3,235 2.9 3,600 3.2 4,000 3.6 4,215 4.0 4,300 4.3 1,430 4 3,085 2.7 3,455 3.0 3,820 3.2 4,140 3.6 4,260 3.8 1,385 5 2,980 2.5 3,280 2.7 3,640 2.9 3,985 3.2 4,170 3.4 1,340 6 2,880 2.3 3,135 2.5 3,475 2.7 3,840 2.9 4,080 3.0 1,805 1 - - - - - - 3,210 4.9 - - 1,755 2 - - - - 3,410 4.9 3,190 4.6 3,110 4.3 1,705 3 3,710 5.0 3,585 4.9 3,310 4.5 3,130 4.2 3,010 3.9 1,655 4 3,600 4.8 3,470 4.6 3,210 4.2 3,030 3.8 2,910 3.6 1,605 5 3,510 4.3 3,335 4.1 3,110 3.7 2,920 3.4 2,800 3.2 1,555 6 3,400 3.9 3,220 3.8 3,010 3.4 2,810 3.2 2,710 3.0 52 (800) 627-4499 • Fax: (608) 221-2824 www.RenewAire.com 53 42" 40" 74 1/2" 57" Back View OA Blower and Filter Access RA FA 33 1/8" Wiring In 7/8" Dia. OA EA E-box Access Unit Dimensions HE4XRTC OA Left View EA OA RA FA 82 1/4" 5 1/2" 36 3/8" Service Area RA FA RA Filter Access Front View 80 3/4" 57 1/2" Top View 82 1/4" Service Area Core and EA Blower Access EA Blower Access EA EA 139 1/2" Service Area OA 46 1/2" OA Blower and Filter Access 81 3/4" Right View RA FA 37" EA: OA: RA: FA: 6 1/2" 11 1/4" typ 25 1/2" 45" Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside HE6XRT Specifications Outdoor Unit Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 1,500-6,500 CFM AHRI 1060 Certified Core: Six L125-00 Airflow Rating Points (for AHRI): 4,500 CFM and 3,375 CFM Number Motors: Two G5 Performance Effectiveness (%) 4,000 Volts HZ Phase FLA Min. Cir. Amps Max. Fuse Size 5 208-230 460 575 60 60 60 Three Three Three 14.2-13.0 6.5 5.0 32.6 14.9 11.3 45 20 15 7.5 208-230 460 575 60 60 60 Three Three Three 20.9-19.2 9.6 7.6 47.0 21.6 17.1 70 30 25 Control Voltage: 24 VAC CFM 3,000 HP 5,000 Filters: Twelve total, MERV 8, 2” pleated, 20” x 20” nominal size 6,000 Weight: 2,340 lbs (unit), 2,640 lbs (shipping weight) 80 Shipping Dimensions: 85” W x 114” L x 85” H Sensible Winter 60 Total Summ er Tot al 40 *At AHRI 1060 standard conditions (See certified data on page 67 for core components). Base Type/Airflow Orientations RTV RTF EA OA RTR EA RA OA EA FA OA RA FA FA RA RA FA RTH EA OA Airflow Performance External Static Pressure (Inches Water Column) Motor HP Blower RPM Nominal Turns Open 0.0 CFM 0.25 BHP CFM 0.5 BHP CFM 0.75 BHP CFM 1.0 BHP CFM 1.25 BHP CFM 1.5 BHP CFM BHP 5 1,460 1,610 1,725 4.5 2 0 5,005 5,550 - 3.2 4.2 - 4,800 5,375 - 3.2 4.2 - 4,650 5,250 - 3.1 4.1 - 4,475 5,100 5,525 3.0 4.1 5.0 4,200 4,900 5,475 2.9 4.0 5.0 4,000 4,650 5,200 2.8 3.9 4.9 3,750 4,500 5,050 2.8 3.8 4.8 7.5 1,560 1,740 1,865 4.5 2 0 5,275 5,950 6,500 3.7 5.0 6.5 5,200 5,825 6,350 3.6 5.0 6.5 4,900 5,625 6,225 3.5 4.9 6.4 4,775 5,490 6,125 3.5 4.9 6.4 4,550 5,325 5,910 3.4 4.8 6.3 4,350 5,125 5,825 3.3 4.7 6.2 4,125 4,950 5,625 3.3 4.7 6.1 54 (800) 627-4499 • Fax: (608) 221-2824 RIGHT VIEW 108 1/2" Base EA OA 78 1/4" Overall EA 60 7/8" RA BACK VIEW 49" 24" 81 1/2" Base 21 7/8" Note: All units have an integral exhaust air backdraft damper. Power and Control Wiring Entries 7/8" Dia. Core Access (RTF,RTH Only) RA 34" Min. Clearance LEFT VIEW 62" 18" 108 1/2" Base FA 39 1/2" Min. Clearance TOP VIEW FA 112 3/4" Unit Roof 63 1/2" EA 39 3/4" Power and Control Wiring Entries 41 3/4" 12" (RTV,RTR) 22" 59 3/8" 4" 160 1/4" Service Area 4" 9" Unit Dimensions 24" 77" HE6XRT 36" www.RenewAire.com 55 165" Service Area FRONT VIEW Blower Access 85 1/2" Unit Roof EA RTH, RTR UNITS ONLY: FA BLOWER Outlet is 18" x 24". 24" x 36" Duct Flange is also supplied. Field install only in location shown. Front Views at 0.5X: BLOWER ROTATION RTV, RTF UNITS ONLY: FA Blower Outlet is 16" x 22". Curb accepts up to 24" x 36" duct; see separate Curb drawing. Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside CURB6X EA: OA: RA: FA: HE8XRT Specifications Outdoor Unit Ventilation Type: Static Plate, Heat and Humidity Transfer Typical Airflow Range: 2,000-8,000 CFM AHRI 1060 Certified Core: Eight L125-00 Airflow Rating Points (for AHRI): 6,000 CFM and 4,500 CFM Number Motors: Two Effectiveness (%) 2,000 4,000 6,000 Max. Fuse Size Three 14.2-13.0 Three 6.5 5.0 Three 32.6 14.9 11.3 45 20 15 60 60 60 Three 20.9-19.2 Three 9.6 Three 7.6 47.0 21.6 17.1 70 30 25 60 60 60 Three 29.0-26.8 Three 13.4 Three 10.0 65.3 30.2 22.5 90 45 35 Volts HZ Phase 5 208-230 460 575 60 60 60 7.5 208-230 460 575 10 208-230 460 575 G5 Performance CFM Min. Cir. Amps HP 8,000 FLA Control Voltage: 24 VAC 80 Filters: Sixteen total, MERV 8, 2” pleated, 20” x 20” nominal size Sensible Winte Weight: 2,730 lbs (unit), 3,080 lbs (shipping weight) r Tota 60 Summ Shipping Dimensions: 85” W x 114” L x 85” H l er To tal 40 *At AHRI 1060 standard conditions (See certified data on page 67 for core components). Base Type/Airflow Orientations RTV RTF EA OA RTR EA RA OA EA FA OA RA FA FA RA RA FA RTH EA OA Airflow Performance External Static Pressure (Inches Water Column) Motor HP Blower RPM Nominal Turns Open 0.0 CFM 0.25 BHP CFM 0.5 BHP CFM 0.75 BHP CFM 1.0 BHP CFM 1.25 BHP CFM 1.5 BHP CFM BHP 5 1,460 1,610 1,725 4.5 2 0.5 5,575 6,200 6,550 3.2 4.3 5.0 5,425 6,010 6,380 3.2 4.3 5.0 5,200 5,875 6,210 3.2 4.2 5.0 5,000 5,700 6,100 3.2 4.2 5.0 4,775 5,500 5,880 3.1 4.2 4.9 4,550 5,325 5,730 3.0 4.1 4.8 4,270 5,125 5,510 2.9 4.1 4.8 7.5 1,560 1,740 1,865 4.5 2 0 6,000 6,700 - 3.9 5.3 - 5,850 6,575 - 3.9 5.3 - 5,650 6,400 - 3.8 5.3 - 5,475 6,300 6,800 3.8 5.3 7.5 5,275 6,125 6,675 3.8 5.3 7.5 5,100 5,950 6,500 3.7 5.2 7.5 4,875 5,750 6,375 3.7 5.2 7.4 10 1,810 2,020 2,105 4.5 2 1 7,000 7,850 - 6.1 8.5 - 6,875 7,745 - 6.1 8.5 - 6,750 7,625 7,950 6.1 8.5 9.6 6,600 7,450 7,800 6.0 8.4 9.6 6,425 7,350 7,725 6.0 8.4 9.6 6,275 7,200 7,600 6.0 8.3 9.5 6,100 7,050 7,450 5.9 8.3 9.5 56 (800) 627-4499 • Fax: (608) 221-2824 RIGHT VIEW 108 1/2" Base EA OA EA RA BACK VIEW 49" 24" 81 1/2" Base 21 7/8" (RTV,RTR) OA Hoods on Rooftop Units only. (RTF,RTH Only) OA Core Access 27 1/4" 35" OA LEFT VIEW 62" 18" 108 1/2" Base FA 39 1/2" Min. Clearance TOP VIEW FA 112 3/4" Unit Roof 29" RA 63 1/2" EA 39 3/4" Power and Control Wiring Entries 34" Min. Clearance 59 3/8" 60 7/8" Note: All units have an integral exhaust air backdraft damper. Power and Control Wiring Entries 7/8" Dia. 78 1/4" Overall 41 3/4" 183 1/4" Service Area 4" 9" Unit Dimensions 24" 77" HE8XRT 22" 36" 4" www.RenewAire.com 57 165" Service Area FRONT VIEW Blower Access 85 1/2" Unit Roof EA RTH, RTR UNITS ONLY: FA BLOWER Outlet is 18" x 24". 24" x 36" Duct Flange is also supplied. Field install only in location shown. Front Views @ 0.5X: BLOWER ROTATION RTV, RTF UNITS ONLY: FA Blower Outlet is 16" x 22". Curb accepts up to 24" x 36" duct; see separate Curb drawing. Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside CURB8X EA: OA: RA: FA: Applied Products • Cost effective energy recovery for virtually any air handling system. • AHRI certified performance data for efficiency and cross leakage. • Field assembled into air handling systems or integrated in custom packaged air handlers. • Unlimited airflow capacity. • UL tested flammability and smoke generation that meets NFPA 90A and 90B test standards for commercial applications. • Flexible installation and easy servicing. • Ten year core warranty. RenewAire means Trouble-Free ERV. Installation Example Central Air Handler using CA4X and exhaust and make-up air blowers. (CA-Series provide side service access and a “side-by-side” airflow arrangement.) CA4X Similar designs can use PA-Series arrays. (PA-Series provide top service access and an “over-under” airflow arrangement.) 58 (800) 627-4499 • Fax: (608) 221-2824 CA & PA Series Applied Energy Recovery Ventilators: CA2X, CA3X, CA4X, PA6X, PA9X, PA8X & PA12X Part I - General A. Product Specification 1. Energy Recovery Ventilator (ERV) shall be a packaged unit as manufactured by RenewAire and shall transfer both heat and humidity using static plate core technology. B. Quality Assurance 1. The energy recovery cores used in these products shall be third party Certified by AHRI under its Standard 1060 for Energy Recovery Ventilators. AHRI published certifications shall confirm manufacture’s published performance for airflow, static pressure, temperature and total effectiveness, purge air (OACF) and exhaust air leakage (EATR). Products that are not currently AHRI Certified will not be accepted. 2. The energy recovery core shall be a UL Listed Component complying to UL Standard 723. Manufacturer shall be able to provide evidence of independent testing of the core by Underwriters Laboratory (UL), verifying a maximum flame spread index (FSI) of 25 and a maximum smoke developed index (SDI) of 50 thereby meeting NFPA 90A and NFPA 90B requirements for materials in a compartment handling air intended for circulation through a duct system. 3. The ERV core shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of ten years from the date of purchase. The balance-of-unit shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of two years from the date of purchase. Part II – Performance A. Energy Transfer The ERV shall be capable of transferring both sensible and latent energy between airstreams. Latent energy transfer shall be accomplished by direct water vapor transfer from one airstream to the other, without exposing transfer media in succeeding cycles directly to the exhaust air and then to the fresh air. B. Passive Frost Control The ERV core shall perform without condensing or frosting under normal operating conditions (defined as outside temperatures above -10°F and inside relative humidity below 40%). Occasional more extreme conditions shall not affect the usual function, performance or durability of the core. No condensate drains will be allowed. 3. The unit case shall be constructed of G90 galvanized, 20-gauge steel, with lapped corners and zinc plated screw fasteners. 4. Access doors shall provide easy access to ERV cores and filters. Doors shall have an airtight compression seal using closed cell foam gaskets. 5. Case walls and doors shall be insulated with 1 inch, 4 pound density, foil/scrim faced, high-density fiberglass board insulation, providing a cleanable surface and eliminating the possibility of exposing the fresh air to glass fibers. PA-Series bottom panels shall be insulated with ¼ inch sheet rubber insulation. 6. The ERV cores shall be protected by a MERV-8 rated, 2” nominal, pleated, disposable filter in both airstreams. 7. CA-Series cabinet construction shall allow stacking of units up to three cabinets high for larger airflow applications. Hinged and latched access doors will be provided on each end of the unit. 8. PA-Series shall use RenewAire patented modular vertical stack of cores (US Patent 5,660,228) allowing assembly of unlimited sizes of ERV systems. Latched access doors are provided on the top of each unit. B. Options (Select options based on application requirements) 1. Provide unit and duct connection orientation per project schedule. 2. Provide double wall construction with 24-gauge galvanized steel liner (CA-Series only). 3. CA and PA-Series units are available pre-assembled on a structural steel base. Part IV – Installation A. Unit Location 1. Locate and orient unit to provide the shortest and most straight duct connections. Provide service clearances as indicated on the plans. Locate system blowers (provided by others) distant from sound critical occupancies. 2. Provide a poured concrete equipment pad for all floor mounted units. The pad thickness, and floor plan dimensions to be determined based on the unit selected, and site structural considerations. 3. Provide a structurally suitable support for the base of any wall mounted or hung units. B. Vibration Isolation C. Continuous Ventilation 1. No moving parts are allowed in the ERV modular assemblies. Unit shall have the capacity to operate continuously without the need for bypass, recirculation, pre-heaters or defrost cycles under normal operating conditions. C. Duct Design D. Positive Airstream Separation Water vapor transfer shall be through molecular transport by hydroscopic resin and shall not be accomplished by “porous plate” mechanisms. Exhaust and fresh airstreams shall travel at all times in separate passages, and airstreams shall not mix. E. Laminar Flow Airflow through the ERV core shall be laminar over the products entire operating airflow range, avoiding deposition of particulates on the interior of the energy exchange plate material. 1. All ductwork shall be designed, constructed, supported and sealed in accordance with SMACNA HVAC Duct Construction Standards and pressure classifications. 2. At a minimum all duct runs to the outdoors shall be thermally insulated at levels appropriate to the local climate. A continuous vapor barrier shall also be provided on warm surface of the insulation. D. Sound Control Part III – Product 1. The ERV cores shall act as flow straighteners and sound attenuators. This attribute can be used to isolate mechanical noise from blowers and other mechanical equipment from sound critical occupancies. A. Construction E. Test and Balancing 1. The energy recovery component shall be of fixed-plate cross-flow construction, with no moving parts. 1. Test and Balancing may not begin until 100% of the installation is complete and fully functional. 2. No condensate drain pans or drains shall be allowed and unit shall be capable of operating in both winter and summer conditions without generating condensate. 2. Follow National Comfort Institute (NCI) air test and balance procedures specific to Heat Recovery Ventilator Balancing Procedure including standard reports to the owner’s representative. 59 www.RenewAire.com CA-Series Indoor Unit - Up to 20,000 CFM in Stacked Arrays Specifications Ventilation Type: Static Plate, Heat and Humidity Transfer Insulated sheet metal cabinets with energy exchange cores and filters. Individual CA-Series units or stacks of units can be built into larger air handling systems. Blower not included and must be specified to meet job requirements. Description Typical Airflow Range CFM AHRI 1060 Certified Core Airflow Rating Points (for AHRI) Effectiveness (%) 1,000 1,500 Two L125-00 Three L125-00 Four L125-00 2,250 and 1,690 CFM 3,000 and 2,250 CFM Unit Weight 225 lbs 325 lbs 400 lbs Shipping Weight 275 lbs 375 lbs 475 lbs Four Total Six Total Eight Total 2,000 Insulation: One inch, high density, FSK faced, fiberglass 80 Sensible Winter To tal Summe r Total 60 40 CA2X CFM 1,250 1,750 2,250 80 2.750 Sensible Winter Tota Summer To l tal 60 40 CA3X Effectiveness (%) CFM Effectiveness (%) CA4X 1,000-4,400 Shipping Dimensions: CA2X - 40” W x 48” L x 41” H CA3X - 40” W x 67” L x 41” H CA4X - 40” W x 87” L x 41” H CFM 500 CA3X 750-3,300 1,500 and 1,120 CFM Filters: MERV 8, 2” pleated 20” x 20” nominal size G5 Performance CA2X 500-2,200 1,000 80 40 CA4X 4X CA CA 3X 2X CA Internal Static Pressure (in. H2O) CA3X 0.5 1,000 2,000 3,000 4,000 Airflow (CFM) 60 (800) 627-4499 • 4,000 *At AHRI 1060 standard conditions (See certified data on page 66 for core components). 2.0 1.0 3,000 Sensible Winter T otal Summe r Total 60 Airflow Performance 1.5 2,000 Fax: (608) 221-2824 www.RenewAire.com 61 39 3/4" Left View Top View D ( Minimum Service Area) 2.5000 End View 34 3/4" CA4X 81-5/8” 32” 149” 116” 7-5/8” 39-3/4” 34 3/4" EA: OA: RA: FA: Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside E B F B F E Right View A Note: Filters are provided for installation in any two of the locations shown, depending on which duct connections are selected for inlets. Filters are 2" x 20" x 20" pleated disposable. Double Wall Construction Available Options: 15" 2.5000 CA3X 62” 24” 130” 96” 5-5/8” 29-5/8” 1" C (Maximum Service Area) CA2X 42” 14” 111” 77” 5-5/8” 19-3/4” 1" Unit Dimensions A B C D E F 15" CA-SERIES 34 3/4" PA-Series Specifications Indoor Unit - Unlimited Airflow in Multiple Arrays Ventilation Type: Static Plate, Heat and Humidity Transfer Insulated sheet metal panels easily slide into receivers to enclose stacks of energy exchange cores using unique patented design, US Patent 5,660,228 Individual PA-Series units can be joined together to provide unlimited airflow capacities for larger air handling systems. Blower not included and must be specified to meet job requirements. Description G5 Performance PA6X PA8X PA9X PA12X Typical Airflow Range CFM 1,500-6,600 2,000-8,800 2,250-9,900 3,000-13,200 AHRI 1060 Certified Core Six L125-00 Eight L125-00 Nine L125-00 Twelve L125-00 Airflow Rating Points (for AHRI) 4,500 and 3,375 CFM 6,000 and 4,500 CFM 6,750 and 5,062 CFM 9,000 and 6,750 CFM Unit Weight 565 lbs 695 lbs 800 lbs 980 lbs Shipping Weight 650 lbs 900 lbs 990 lbs 1,180 lbs Filters: MERV 8, 2” pleated, 20” x 20” nominal size PA6X - 12 Total PA9X - 18 Total PA8X - 16 Total PA12X - 24 Total Insulation: One inch, high density, FSK faced, fiberglass CFM CFM 4,000 5,000 3,500 6,000 80 Sensible 60 Winter Tota l Summer To tal 40 PA6X Effectiveness (%) Effectiveness (%) 3,000 5,000 80 Winter To tal Summer Total 40 PA9X CFM 6,500 5,000 8,000 80 Sensible 60 Winter T otal Summer Total 40 PA8X Effectiveness (%) Effectiveness (%) 5,000 7,000 9,000 Sensible Winter Tota l Summer To tal 60 40 PA12X X PA 1 2X PA 9 PA 8 X X 2.0 PA 6 Internal Static Pressure (in. H2O) Airflow Performance 1.0 CA3X 0.5 3,000 6,000 9,000 12,000 Airflow (CFM) 62 (800) 627-4499 • 11,000 80 *At AHRI 1060 standard conditions (See certified data on page 66 for core components). 1.5 8,000 Sensible 60 CFM 3,500 6,500 Fax: (608) 221-2824 www.RenewAire.com 63 Side View 35 1/2" Service Area G 22 1/2” 35 1/2" 35 1/2" Unit Dimensions PA-SERIES PA-9X/12X 565 APPROX. WEIGHT Front View D (Duct Flange) A (Overall) Service Area Top View A = 109 1/2 A = 73 1/4 PA-6X/8X PA6X 73-1/4” 72-3/4” 28” 1-1/2” 66-1/4” A D E F G E E 810 5” F PA9X 109-1/2” 109” 28” 1-1/2” 66-1/4” 700 PA8X 73-1/4” 72-3/4” 37” 3-1/8” 86” EA: OA: RA: FA: 35 1/2" Arrangement 4 Same-side Entries Parallel-path Airflows Performance Derating: Airflow arrangements 3 & 4 result in lower energy transfer. Reduce sensible effectiveness by 2 percentage points. Reduce total effectiveness by 1 percentage point. 35 1/2" 2 35 1/2" Arrangement 2 Same-side Entries Cross-path Airflows 35 1/2" 2 2 1 2 1 Arrangement 3 Opposite-side Entries Parallel-path Airflows 1 1 1 2 2 1 1 2 Exhaust Air to outdoors Outdoor Air intake Room Air to be exhausted Fresh Air to inside Available Airflow Arrangements (Side Views) Assembled on structural forklift base Knockdown Available Options: Arrangement 1 Opposite-side Entries Cross-path Airflows 2 1 1000 PA12X 109-1/2” 109” 37” 3-1/8” 86” Commercial Controls & Interconnection Options These controls are intended to turn RenewAire commercial energy recovery ventilation systems on and off at appropriate times. Specification, installation and set-up is an easy process. RenewAire units should be ordered with the 24 volt contactor option for all controls. It is not necessary that RenewAire controls be used to operate RenewAire units. A wide range of controls or building automation systems may be used. Make sure units are ordered with compatible contactor control voltage. RenewAire residential units have their own line of compatible controls that are not intended to operate RenewAire commercial units. Digital Time Clock TC7D • • • • • • up to 8 on/off cycles per day or 56 per week 24 VAC power requirement battery back-up wall mount or outdoor enclosure options wall mount fits any 4” x 4” electrical box optional RenewAire transformer relay package (TR40) may be used Motion (occupancy) Control MC • • • • • passive infared sensor adjustable time-off delay to 30 minutes 24 VAC power requirement ceiling mount or directable wall mount covers up to 1500 sq. ft. floor space TC7D-W Wall Mount TC7D-E Control In NEMA 3R Enclosures MC-C Ceiling Mount MC-W Wall Mount ceiling mount - walking motion coverage up to 22 foot radius wall mount - various coverage patterns up to 90 linear feet of sensitivity • requires the use of RenewAire transformer relay package (TR40) (ordered separately) Carbon Dioxide Control CO2 CO2-W Wall Mount • • • • • • • adjustable control from 600-2000 PPM digital display 24 VAC power requirement computer/BAS interface for information and control self calibrates during periods of low occupancy wall mount or add duct mount accessory requires the use of RenewAire transformer relay package (TR40) (ordered separately) 64 (800) 627-4499 • Fax: (608) 221-2824 CO2-D Duct Mount DH24 Dehumidistat Control • • • • • DH24 Wall Mount secondary control to time clock or other primary control mechanical switching of 24 VAC (or 120 VAC) adjustable from 0 - 100% relative humidity wall mount to single gang box Note: RenewAire ERVs are not to be used for applications where indoor relative humidity exceeds 50% RH for extended periods of time Disconnect Switch DS • • • • • fused or non-fused indoor or NEMA 3R exterior enclosures - I or E installation voltage must be specified 115, 208-230, 460 installed on unit and wired to unit contactor disconnects are configured as part of the model numbering for a unit (see page 67) Transformer Relay Package TR40 • • • • • • IBC provides a 24 VAC, 40 VA class II power supply for unit control includes isolation relay with low voltage circuit breaker handles any RenewAire unit with one contactor installation voltage must be specified 115, 208-230, 460 installed in unit electric box TR40 is configured as part of the model numbering for a unit (see page 67) Independent Blower Control • adds a second contactor to allow independent control of exhaust fan and supply fan • may be used to provide economizer (no heat recovery operation) function • can provide relief fan or make-up air function to benefit building pressurization • IBC is configured as part of the model numbering guide for a unit (see page 67) 65 www.RenewAire.com HVI Tested/Certified Per CSA C439 BR70/EV70 - Ventilation Performance Gross Airflow Net Supply Airflow Supply Exhaust in. wg L/S CFM L/S CFM L/S CFM 0.1 41 86 42 89 46 97 0.2 34 73 35 75 39 84 0.3 28 59 29 61 32 69 0.4 21 46 22 47 25 53 0.9 Pa 25 50 75 100 in. wg. (PA = n x 248.8) Ext. Static Pressure Electrical Requirements Volts 120 Amps 1.0 Exhaust Air Transfer Rao = 4% @ 0.2 in. wg (50 PA) and 4% @ 0.4 in. wg (100 PA) Net Airflow Average Power Watts L/S CFM 32 69 94 30 64 94 Sensible Recovery Apparent Sensible Efficiency % Effectiveness % 66 0.6 0.5 0.4 0.3 0.2 0.1 0 77 Total Recovery Efficiency % 42 25 50 75 100 125 150 175 CFM (L/S = n x 0.4719) Net Moisture Transfer % Gross Supply Gross Exhaust 53 BR130/EV130 - Ventilation Performance Gross Airflow Net Supply Airflow Supply Exhaust in. wg L/S CFM L/S CFM L/S CFM 0.1 70 148 71 151 75 159 0.2 66 141 67 143 69 147 0.3 62 132 63 134 64 135 0.4 53 113 54 115 56 119 0.5 44 94 45 96 47 99 0.6 32 69 33 70 29 62 0.7 24 52 25 53 21 45 0.9 in. wg. (PA = n x 248.8) Ext. Static Pressure Pa 25 50 75 100 125 150 175 0.7 0.0 BR70/EV70 - Energy Performance Supply Temperature C° F° Heating 0° 32° Cooling 35° 95° 0.8 Electrical Requirements Volts 120 Amps 1.3 Exhaust Air Transfer Rao = 2% @ 0.2 in. wg (50 PA) and 2% @ 0.4 in. wg (100 PA) 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 0 25 50 75 100 125 150 175 CFM (L/S = n x 0.4719) BR130/EV130 - Energy Performance Supply Temperature C° F° Heating 0° 32° Cooling 35° 95° Net Airflow Average Power Watts L/S CFM 58 124 121 59 126 121 Sensible Recovery Apparent Sensible Efficiency % Effectiveness % 72 Gross Supply Net Moisture Transfer % 80 Total Recovery Efficiency % 46 Gross Exhaust 55 EV200 - Ventilation Performance Pa 25 50 75 100 125 150 175 in. wg 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Net Supply Airflow L/S 97 90 88 83 79 70 57 CFM 207 192 186 176 168 149 122 0.9 Gross Airflow Supply Exhaust L/S CFM L/S CFM 100 213 109 232 93 199 104 221 90 192 101 216 85 181 96 204 81 173 88 187 72 154 76 162 59 126 68 145 in. wg. (PA = n x 248.8) Ext. Static Pressure Electrical Requirements Volts 120 Amps 1.5 Exhaust Air Transfer Rao = 3% @ 0.2 in. wg (50 PA) and 3% @ 0.4 in. wg (100 PA) 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 0 25 50 75 100 125 150 175 200 225 250 CFM (L/S = n x 0.4719) EV200 - Energy Performance Supply Temperature C° F° Heating 0° 32° Cooling 35° 95° Net Airflow Average Power Watts L/S CFM 85 181 157 85 180 155 Sensible Recovery Apparent Sensible Efficiency % Effectiveness % 78 Gross Supply Net Moisture Transfer % 85 Total Recovery Efficiency % 52 Gross Exhaust 62 EV300 - Ventilation Performance Pa 100 125 150 175 200 225 250 in. wg 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Net Supply Airflow L/S 145 141 136 126 117 94 73 CFM 310 300 289 268 249 199 155 Gross Airflow Supply Exhaust L/S CFM L/S CFM 150 320 143 305 145 310 138 295 140 299 127 270 130 276 114 242 121 251 92 195 97 206 79 169 75 160 65 138 in. wg. (PA = n x 248.8) Ext. Static Pressure Electrical Requirements Volts 120 Amps 3.3 Exhaust Air Transfer Rao = 4% @ 0.4 in. wg (100 PA) 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 0 50 100 150 200 250 300 350 CFM (L/S = n x 0.4719) EV300 - Energy Performance Supply Temperature C° F° Heating 0° 32° Cooling 35° 95° Net Airflow Average Power Watts L/S CFM 138 293 310 120 272 299 Sensible Recovery Apparent Sensible Efficiency % Effectiveness % 68 Net Moisture Transfer % 76 Total Recovery Efficiency % 38 45 66 (800) 627-4499 • Fax: (608) 221-2824 Gross Supply Gross Exhaust AHRI 1060-2005 Certified Performance AHRI-1060 Certified Performance - Model Number L85-G5 Type Tilt Angle Nominal Airflow Pressure Drop Plate N/A 100% - 450 SCFM 75% - 338 SCFM 0.6 in. H20 0.5 in. H20 Leakage Ratings Thermal Effectiveness Ratings at 0” Pressure Differential Pressure Differential EATR Purge Angle OACF or Setting Test 1 -1 in. H20 1.0% 1.00 N/A Test 2 0 in. H20 0.0% 1.02 N/A Test 3 1 in. H20 0.0% 1.05 N/A Net Net Airflow Sensible Nominal Airflow Sensible Latent Total 450 Heating CFM Cooling 73% 73% 53% 46% 66% 56% 450 CFM 338 Heating CFM Cooling 77% 77% 60% 52% 71% 61% 338 CFM Net Latent Net Total 73% 73% 53% 46% 66% 56% 77% 77% 60% 52% 71% 61% AHRI-1060 Certified Performance - Model Number L125-G5 Type Tilt Angle Nominal Airflow Pressure Drop N/A 100% - 750 SCFM 75% - 563 SCFM 0.65 in. H20 0.45 in. H20 Plate Leakage Ratings Thermal Effectiveness Ratings at 0” Pressure Differential Pressure Differential EATR Purge Angle OACF or Setting Test 1 -1 in. H20 1.0% 1.00 N/A Test 2 0 in. H20 0.0% 1.02 N/A Test 3 1 in. H20 0.0% 1.05 N/A NOTE: SCFM = Standard Cubic Feet per Minute Net Net Airflow Sensible Nominal Airflow Sensible Latent Total 750 Heating CFM Cooling 71% 71% 52% 43% 64% 53% 750 CFM 563 Heating CFM Cooling 75% 75% 59% 50% 69% 59% 563 CFM OACF = Outdoor Air Correction Factor Net Latent Net Total 71% 71% 52% 43% 64% 53% 75% 75% 59% 50% 69% 59% EATR = Exhaust Air Transfer Ratio N/A = Not Applicable Energy recovery component certified in accordance with AHRI Standard 1060-2005. Actual performance in packaged equipment may vary. Model Numbering Guide 6 STANDARD FEATURES MODEL NUMBER CORE: "J" = G5 7-8 "IN" = INDOOR J I N 1 2 3 4 5 6 Not all options are available on every model. 7 8 12-20 UNUSED IN PA, CA MODELS - - - - - - - - - - - 9 10 11 12 13 14 15 16 17 18 19 20 21 22 N 23 24 25 25 UL: "N" = NON-LISTED MULTIPLE-CHOICE OR OPTIONAL FEATURES 1-2 MODEL: "CA" = CABINET APPLIED "PA" = PANELIZED APPLIED QTY OF CORES: 24 OPTION 4: PRE-ASSEMBLY "K" = KNOCKDOWN (PA MODELS) "A" = ASSEMBLED (PA MODELS) "-" = NOT APPLICABLE (CA MODELS) 3-5 "nX" = (n) CORES n = 2, 3, 4 (CA MODELS) n = 6, 8, 9, 12 (PA MODELS) BASE TYPE (SEE DIAGRAM) 23 OPTION 3 (RESERVED): "-" = NONE 22 OPTION 2 (RESERVED): "-" = NONE 9 (CA) "-" (NONE) (PA) "9" = FORKLIFT BASE CA & PA MODELS 10 AIRFLOW ORIENTATION (UNUSED IN CA MODELS) "1" = OPPOSITE-SIDE ENTRY, CROSS-FLOW "2" = SAME-SIDE ENTRY, CROSS FLOW "3" = OPPOSITE-SIDE ENTRY, PARALLEL-FLOW "4" = SAME-SIDE ENTRY, PARALLEL-FLOW "-" = DEFAULT IN CA MODELS AND IN PA MODELS WITH PRE-ASSEMBLY OPTION "K" (KNOCK-DOWN). 21 OPTION 1 (RESERVED): "-" = NONE 11 WALL TYPE (UNUSED IN PA MODELS): "S" = SINGLE (CA MODELS ONLY) "D" = DOUBLE (CA MODELS ONLY) 67 www.RenewAire.com 1 2 3 4 5 6 J 6 7 7-8 - 9 VOLTAGE: (SEE RESTRICTIONS 2, 3, 4 & 5) FA HORSEPOWER RESTRICTION 6 EA HORSEPOWER 15 OPTION 4: OTHERS OPTION 2: FILTER MONITOR (RESTRICTION 13) 22 OPTION 1: 24V TRANS. (RESTRICTIONS 11 & 12): DISCONNECT (RESTRICTIONS 9 & 10): UNIT CONTROL (RESTRICTIONS 7 & 8) EV/HE MODELS "A" = (1) 24V CONTACTOR "D" = (2) 24V CONTACTORS "R" = INVERTER READY (NO CONTACTOR) 19 "N" = NON-FUSED "F" = FUSED "-" = NONE 20 "-" = NONE "T" = TR40 (TRANSFORMER WITH ISOLATION RELAY) 21 "-" = NONE, "F" = FILTER MONITOR BOTH AIRSTREAMS OTHER OPTIONS (RESERVED) 23 "-" = NONE, "W" = WHITE PAINT, "C" = CUSTOM PAINT "X" = CUSTOM UNIT 24 UL LISTING (SEE RESTRICTION 15): UL: "L" = LISTED "N" = NON-LISTED 25 UNUSED IN THESE MODELS 14: SOME UNITS WITH CUSTOM "X" CODE NOT UL-LISTED. 13: FILTER MONITORS NOT AVAILABLE IN EV450. 12: TRANSFORMER CODE "T" (TR40) NOT AVAILABLE WITH UNIT CONTROL CODES "D" (2 CONTACTORS) OR "R" (INVERTER READY), EXCEPT IN MODELS HE-6X & HE-8X. 11: TRANSFORMER CODE "T" (TR40) AVAILABLE ONLY WITH VOLTAGE CODES 1, 4, 5 & 9. 10: DISCONNECT CODES "N" & "F" NOT AVAILABLE WITH UNIT CONTROL CODE "R" (INVERTER READY). 9: DISCONNECT CODES "N" & "F" AVAILABLE ONLY WITH VOLTAGE CODES 1, 4, 5, 8 & 9. 8: UNIT CONTROL CODE "D" (2 CONTACTORS) NOT AVAILABLE IN MODEL EV450. 7: UNIT CONTROL CODE "R" (INVERTER READY) NOT AVAILABLE WITH PHASE CODE "1" (SINGLE PHASE), OR IN MODEL EV450. 6: VOLTAGE CODES "1" & "6" AVAILABLE ONLY WITH FA/EA HORSEPOWER CODES "H", 'Q" & "-". 5: VOLTAGE CODE "8" (575V) NOT AVAILABLE WITH HORSEPOWER CODES "H", "Q" OR WITH MODEL EV450. VOLTAGE CODES "1" (115V), "6" (115/208-230V), "7" (208-230/460V), "9" (277V) NOT AVAILABLE IN HE-6X, HE-8X. VOLTAGE CODE "5" (208-230V) NOT AVAILABLE WITH PHASE CODE "1" (SINGLE-PHASE) IN MODELS HE-6X & HE-8X. 4. VOLTAGE CODE "9" (277V) AVAILABLE ONLY WITH HORSEPOWER CODES "H", "Q" OR EV450 MODEL. 3: VOLTAGE CODES "4", "7" & "8" AVAILABLE WITH PHASE CODE "3" (THREE-PHASE) ONLY. 2: VOLTAGE CODES "1", "6" & "9" AVAILABLE WITH PHASE CODE "1" (SINGLE-PHASE) ONLY. 1: BASE TYPE "C" NOT AVAILABLE WITH MODELS EV450, HE-6X, HE-8X. BASE TYPE "T" AVAILABLE ONLY IN HE-6X, HE-8X. RESTRICTIONS: Note: Not all options are available on every model. Model Numbering Guide For Technical Support E-mail: [email protected] To Place an Order E-mail: [email protected] "H" = 0.75 HP EPACT DIRECT-DRIVE (HE-1X ONLY) "J" = 1.5HP EPACT (HE-2X ONLY) "K" = 2HP EPACT (HE-2X, HE-3X, HE-4X ONLY) "L" = 3HP EPACT (HE-3X, HE-4X ONLY) "M" = 5HP EPACT (HE-3X, HE-4X, HE-6X, HE-8X ONLY) "N" 7.5HP EPACT (HE-6X, HE-8X ONLY) "P" 10HP EPACT (HE-8X ONLY) "Q" = (2) 0.75HP EPACT DIRECT-DRIVE (HE-2X ONLY) "-" = DEFAULT IN EV450 14 13 PHASE: "1" = SINGLE-PHASE, "3" = THREE-PHASE 12 "1" = 115V, "4" = 460V, "5" = 208-230V, "6" = 115/208-230V, "7" = 208-230/460V, "8" = 575V, "9" = 277V - - - 16-18 UNUSED IN HE MODEL 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 WALL TYPE: "S" = SINGLE, "D" = DOUBLE 11 "V", "H", "T" (INDOOR UNITS) "V", "H", "R", "F", "C" (ROOFTOP UNITS) "-" - DEFAULT IN HE450 8 10 CORE: "J" = G5 1-5 BASE TYPE (SEE RESTRICTION 1) "IN" = INDOOR, "RT" = ROOFTOP INDOOR/OUTDOOR "EV450", "HE-1X", "HE-2X" "HE-3X", "HE-4X", "HE-6X, "HE-8X" MODEL MODEL NUMBER STANDARD FEATURES MULTIPLE-CHOICE OR OPTIONAL FEATURES RenewAire Product & Ventilation Commitment RenewAire ventilation products will give you cleaner air to breathe - letting you and your family feel better and healthier AND will do so in the most consistent, controlled, safe and energy-efficient manner possible. Gree n Save Energy Reduce Pollution Ample Airflow Material Efficient Pressure Balanced People Friendly Ve n Quiet Operation Energy Efficient Automatic Control t il a tio n For over 30 years, RenewAire has been a pioneer in the use of plate exchangers that simultaneously tranfer heat and humidity between ventilation airstreams in extreme climates. From cool-dry (Point Barrow, Alaska) to hot-humid (Puerto Rico) climates, RenewAire exceeds customer expectations for effective, reliable ventilation solutions. 1980 First HRV and ERV installations using a variety of plate and wheel technologies. ERV manufacturing begins using Mitsubishi “Lossnay” core. 1987 RenewAire model is the first listed by UL-1812 standard for ERV safety. HVI residential unit certification confirms superior heat and humidity transfer. 1998 2006 New factory achieves LEED-Silver rating. 120,000th North American unit sold. 2007 sales result in 30,000 tons of CO2 emission reductions! Introduction of RD Series dedicated outdoor air system. 2009 2004 Introduction of BREEZE® easy to install residential unit. Energy Star Qualified with energy use in the lowest 20% of comparable buildings. 2007 2001 Over 100 school projects shipped in one year. G4 - 4th generation core introduced with enhanced humidity transfer. 2005 1996 Introduction of first roof-top connected unit (RTC). ARI-1060 commercial product certification of only ERV with 0% cross contamination. 2003 1983 2008 Introduction of V-Series Ventilation Exhaust Fans. G5 - 5th generation core introduced with enhanced humidity transfer. 2010 Full Line of Ventilation Products Residential & Small Commercial • 5 Models • 50 - 300 CFM • built-in 24 V transformer/relay package Commercial Products • • • • 23 Models 250 - 7,950 CFM 1 or 3 phase multi-voltage 24 volt control Applied Products • CA-Series (cabinet) - 500 - 20,000 CFM • PA-Series (panelized) - 1,500 - Unlimited CFM • (requires blowers & manifolds by others) Dedicated Outdoor Air Systems • • • • 4 Models 500 - 4400 CFM integrated VFD for each airstream coil options including DX, chilled water, hot water and combinations Ventilation Exhaust Fans • • • • 4 Models 50 - 150 CFM robust steel housing and duct collar the most efficient line of exhaust fans available in North America This piece was printed using earth-friendly soy ink on 100% post-consumer recycled paper. RenewAire ERVs are proudly manufactured in our LEED-Silver Certified facility using 100% wind generated electricity. © RenewAire LLC, 2010 Part # LIT029