87% - Armstrong

Transcription

87% - Armstrong
CEILING&waLL
SYSTEMS
At your service to create
Between us, ideas become reality ®
A VALUABLE PARTNERSHIP!
MAIN LINE BROCHURE 2011
Ceiling information
Product information
Customer Help-desks
tools
You’ve got questions; we’ve got answers!
Armstrong’s Armstrong Technical Sales
(ATS) teams have the product knowledge
and technical ability to handle your
queries effectively. In addition,
Armstrong’s Customer Order Service
(COS) teams offer an experienced,
friendly, order processing service.
Wherever in the world you’re based,
our experienced customer focused
teams are just a phone call away.
Keeping in touch with Armstrong is
incredibly easy! In addition to providing
you with brochures, data sheets and
magazines, we also have a dedicated
website with specific design and
technical tools such as CAD, 3D
modelling and acoustic calculators.
speCialist teams
Whether you’re a purchasing manager,
contractor or distributor, Armstrong’s
dedicated teams are available to help
you with technical requirements, offer
advice on drawings and project layouts,
and provide an efficient follow-up service.
Our specialist teams are dedicated
to providing customised, design and
technical solutions to meet your project
and supply chain needs.
partnersHip
Nurturing strategic partnerships is
a valuable way to offer customers
the best service levels of quality.
Due to our distributor partnerships,
we currently boast the largest distribution
network in Europe. We team up with
recognised installers through our OMEGA
programme.
Visit us online today!
To further enrich your Armstrong experience,
check out the Armstrong website, where
you can benefit from up-to-date news
and information, inspirational design
ideas, a project gallery, an acoustic
mini-site, product dedicated pages,
downloadable documents and much more!
www.armstrong.eu
tHe omeGa proGramme
Through the OMEGA programme,
Armstrong works closely with
specialist ceiling contractors to reach
the highest levels of performance,
service and sustainability.
OMEGA partners are carefully
selected based on specific Omega
criteria, and they must adhere
to a comprehensive range
of commitments. Among others,
these include complying rigorously
with strict industry standards,
maintaining a thorough
understanding of Armstrong’s
processes and product catalogues,
and constantly submitting projects
to Armstrong for assessment of
workmanship.
PRODUCT SELECTOR
BY APPLICATION AREAS
Office
Healthcare
Mineral & Wood
Metal
Canopy
Reception areas
MADERA, vECTOR range
CLIP-IN, Floating Ceilings
CANOPY range,
INFUSIONS Canopy
Open spaces
OP range, OPTIMA vector
CLIP-IN, HOOK-ON
OPTIMA Canopy,
ULTIMA Canopy
ULTIMA, PERLA
CLIP-IN, HOOK-ON
ULTIMA Canopy,
ORCAL Canopy
dB range
ORCAL PREMIUM,
Floating Ceilings
Corridors
PLANKS range
Corridor Ceilings
CANOPY (INFUSIONS…)
Cafeterias
OP range & COLORTONE
LAY-IN, HOOK-ON
CANOPY range
Meeting rooms
Individual offices
Mineral & Wood
Grid
Designer grid
Receptions & Waiting areas
Consulting rooms
Corridors
Designer grid
Clean rooms
Metal
Canopy
Grid
PERLA, OP range, dB range,
OPTIMA
BIOGUARD range,
CLEAN ROOM FL
CLIP-IN, HOOK-ON B15
CLEAN ROOM GRID
BIOGUARD range
Corridor Ceilings,
ORCAL BIOGUARD
CLEAN ROOM GRID
BIOGUARD ACOUSTIC,
CLEAN ROOM FL
ORCAL BIOGUARD
CLEAN ROOM GRID
CLEAN ROOM FL
BIOGUARD Range
Transport
Mineral & Wood
Metal
Canopy
CLIP-IN, HOOK-ON Perforated
CANOPY range
ULTIMA, PERLA, vector range
CLIP-IN, LAY-IN Perforated
CANOPY range
Lounges
MADERA, ULTIMA, PERLA,
vector range
HOOK-ON, Floating Ceilings
Perforated
CANOPY range
Humid areas
CERAMAGUARD, NEWTONE
CLIP-IN, HOOK-ON (back coated)
Halls & Circulation areas
ULTIMA Canopy
SAHARA Planks
Waiting areas
Grid
Education
Mineral & Wood
Metal
SAHARA MAX / SABBIA
LAY-IN, HOOK-ON
Libraries
OP range, OPTIMA
CLIP-IN, HOOK-ON
CANOPY range
Canteens
OP range,
COLORTONE NEEvA
CLIP-IN, HOOK-ON
CANOPY range
Corridors
Planks range
Corridor Ceilings
Kitchens
BIOGUARD range, PARAFON
HYGIEN
CLIP-IN, LAY-IN (Plain)
Humid areas
CERAMAGUARD, NEWTONE,
HYDROBOARD
Classrooms
Canopy
Grid
ALPHACLASS Frame
ALPHACLASS Frame
ORCAL Canopy
Retail / Leisure
Mineral & Wood
CLIP-IN, HOOK-ON (Plain)
Swimming pools & Spa
Metal
Canopy
CERAMAGUARD, NEWTONE,
OP range
GRAPHIS, COLORTONE, ULTIMA
LAY-IN, HOOK-ON
Cinemas / Theatres
OP range, COLORTONE NEEvA
LAY-IN, HOOK-ON
OP range, COLORTONE
LAY-IN, Floating Ceilings
CANOPY range
CANOPY range
SAHARA
AxIOM C Canopy
Grid
Trulok Corrosive
Resistant Grid
Shops & Department stores
Restaurants
OPTIMA
AxAL Vector
CLIP-IN
PRODUCT SELECTOR
Sustainability
BY PERFORMANCE
acoustics
Compatible
Safe & Healthy
Sustainability
Compatible
Safe & Healthy
%
%
ISO 14021
recycled
content
(%)
acoustics
ISO 14021
light
reflectance
(%)
aw
up to
Sound
absorption
class
nrC
up to
dncw /
dnfw (dB)
up to
rw
(dB)
Fire reaction
Humidity Cleanability
resistance
anti
microbial
air quality
Scratch
resistance
i-ceilings
recycled
content
(%)
light
reflectance
(%)
up to
aw
Sound
absorption
class
nrC
up to
dncw /
dnfw (dB)
up to
rw
(dB)
Fire reaction
Humidity Cleanability
resistance
anti
microbial
air quality
Scratch
resistance
i-ceilings
Mineral Decorative
Mineral Laminated
ULTIMA
44
87
0.75(H)
C
0.75
40
18
A2-s1, d0
95
ULTIMA OP
42
86
1.00
A
0.95
26
10
A2-s1, d0
95
ULTIMA dB
63
87
0.65(H)
C
0.70
43
21
A2-s1, d0
95
OPTIMA
82
87
1.00
A
1.00
7
A2-s1, d0
95
PERLA
45
86
0.65(H)
C
0.70
36
18
A2-s1, d0
95
PERLA OP
42
86
0.95
A
0.90
27
10
A2-s1, d0
95
PERLA dB
63
86
0.60(H)
C
0.65
43
21
A2-s1, d0
95
SIERRA OP
15
83
0.90
A
0.90
29
11
A2-s1, d0
95
NEEvA
20
82
1.00
A
0.95
27
7
A1 (1)
95
wipeable
moist cloth
wipeable
moist cloth
wipeable
moist cloth
wipeable
moist cloth
wipeable
moist cloth
wipeable
moist cloth
wipeable
moist cloth
wipeable
moist cloth
wipeable
moist cloth
✔
✔
COLORTONE DUNE
48
0.55
D
0.55
35
17
A2-s1, d0
95
with dry cloth
✔
✔
COLORTONE NEEvA
20
1.00
A
0.95
24
7
A1 (5)
95
wipeable
moist cloth
✔
✔
COLORTONE FINE FISSURED BLACK
51
0.60(H)
C
0.60
34
-
A2-s2, d0
95
with dry cloth
✔
✔
DESIGN CIRRUS*
33
83
0.55(H)
D
0.55
36
-
A2-s1, d0
up to 95
with dry cloth
✔
✔
✔
✔
GRAPHIS
51
92
0.15(L)
E
0.15
36
-
A2-s2, d0
70
with dry cloth
vISUAL
71
0.95
A
0.90
-
-
A2-s1, d0
70
with dry cloth
0.60(H)
C
0.60
36
18
A2-s1, d0
95
washable
Anti-microbial
ISO 5
Anti-microbial
ISO 5
Anti-microbial
ISO 5
✔
ISO 3 (4)
✔
✔
✔
✔
*Contrast
✔
✔
Specific Solutions
BIOGUARD ACOUSTIC
Mineral Non Laminated
43
up to 85
0.65
C
0.65
39
17
A2-s1, d0
95
with dry cloth
✔
SAHARA MAX / SABBIA
42
84
0.65
C
0.65
35
17
A2-s1, d0
95
with dry cloth
✔
SAHARA dB
61
84
0.60
C
0.55
39
20
A2-s1, d0
95
with dry cloth
✔
CIRRUS
33
83
0.55(H)
D
0.50
36
A2-s1, d0
95
with dry cloth
CIRRUS MAX / CIRRUS 75
65
83
0.70(H)
C
0.75
38
A2-s2, d0
95
with dry cloth
36-44
87
0.15(L)
E
0.15
37
A2-s1, d0
95
with dry cloth
PLAIN
FINE FISSURED
39-51
85
0.60(H)
C
0.60
34
A2-s1, d0
95
52
87
0.15(L)
E
0.15
37
19
A2-s1, d0
95
ORCAL BIOGUARD
Extra Microperforated with fleece &
PREMIUM B15
up to 30
70
0.65
C
0.60
40
18
A2-s2, d0
95
washable
ORCAL BIOGUARD PLAIN
up to 30
85
0.10(L)
-
0.10
44
19
A2-s2, d0
95
20
82
0.95
A
0.95
-
-
A2-s1, d0
95
PARAFON HYGIEN
CLEAN ROOM FL
CERAMAGUARD
with dry cloth
38
NEWTONE
Metal
EXTRA MICROPERFORATED (2)
up to 30
80
0.55(L)
D
0.65
30
-
A2-s2, d0
95
MICROPERFORATED (2)
up to 30
65
0.75
C
0.80
20
6
A2-s2, d0
95
PERFORATED (2)
up to 30
70
0.70(L)
C
0.70
20
6
A2-s2, d0
95
up to 30
85
0.10(L)
Not Classified
0.10
44
19
A1
95
scrubbable
PREMIUM B15
up to 30
depends on
perforation
0.65
C
0.60
47
21
A2-s1, d0
95
wipeable
moist cloth*
78
0.10(L)
-
0.10
36
-
A2-s1, d0
95
washable
79
0.55(MH)
D
0.60
39
-
A1
100
scrubbable
84
0.10(L)
-
0.10
37
-
A2-s1, d0
100
washable
Wood
MADERA vENEERS
-
-
0.50(L)
D
0.60
-
-
B-s2, d0
70
MADERA LAMINATES
-
-
0.50(L)
D
0.60
-
-
B-s2, d0
70
wipeable
dry cloth
wipeable
dry cloth
ISO 5
ISO 5
✔
✔
✔
✔
high pressure
water
cleaning (3)
ISO 3 (4)
✔
✔
OPTIMA CANOPY
82
87
B-s1, d0
90
with dry cloth
ULTIMA CANOPY
44
87
A2-s1, d0
70
with dry cloth
ORCAL CANOPY
30
80
B-s2,d0
90
with dry cloth
AXIOM C CANOPY
25
up to 90
AXIOM KE CANOPY
25
up to 90
INFUSIONS CANOPY
*Wipeable moist cloth for preforated tiles with fleece.
Scrubbable for plain tiles or perforated tiles without fleece.
high pressure
water
Anti-microbial
cleaning (3)
high pressure
water
cleaning
Design / Discontinuous Solutions
wipeable
moist cloth*
wipeable
moist cloth
wipeable
moist cloth
PLAIN (UNPERFORATED)
85
washable/
scrubbable
BIOGUARD PLAIN
SAHARA
45
see detailed data on product pages
with dry cloth
with dry cloth
B-s1,d2
with dry cloth
Our tests have been conducted in an independent third party quality assured laboratory in accordance with current standard (EN ISO...). Armstrong conducts extensive and regular tests on its products. Inevitably slight variations occur over a range of results for the same product. The results above do not necessarily represent the highest achieved but
indicate values that can be consistently and confidently offered.
(1) NEEVA White
(2) Typical values for product with fleece acoustic inlay. For other acoustic solutions, see metal technical pages.
(3) Only for the Clip-In systems with silicone sealed joints.
(4) All Orcal Plain products achieve ISO 3.
(5) Expect Cement & Metal
Latest information available on websites.
www.armstrong.eu
AfricA/Middle eAst/turkey
■ Armstrong World Industries Ltd
Africa Middle East Turkey Division
Armstrong House
38 Market Square
Uxbridge UB8 1NG
Tel.: +44 01895 251122
Fax: +44 01895 272928
e-mail: [email protected]
www.armstrong.eu
israël: www.armstrong.co.il
south Africa: www.armstrong-ceilings.za
turkey: www.armstrong.com.tr
BelgiuM & luxeMBourg
■ Armstrong Building Products B.v.
Bureaux Commerciaux Belgique
Office Building Quadrium
Claudius Prinsenlaan 126
4818 CP Breda
Nederland
Tel.: +32 02 223 00 72
Fax: +31 076 521 04 07
e-mail: [email protected]
www.armstrong-plafonds.be
centrAl europe north
(dk/ee/fin/is/lt/lV/n/pl/s)
■ Armstrong Building Products B.v.
Sp.z.o.o. Oddział w Polsce
ul. Domaniewska 37
02-672 Warszawa
Poland
Tel.: +48 0 22 337 86 10/ 86 11
Fax: +48 0 22 337 86 12
e-mail: [email protected]
latvia: www.armstrong.lv
lithuania: www.armstrong.lt
norway: www.armstrong.no
poland: www.armstrong.pl/sufity
sweden: www.armstrong.se
centrAl europe south
(Al/BA/Bg/cZ/hr/hu/ko/
Md/Me/Mk/ro/rs/sk/si)
■ Bureaux Commerciaux France
Immeuble Paryseine
3 Allée de la Seine
94854 Ivry-sur-Seine
France
Tel.: +33 (0) 1 43 90 45 40
Fax: +33 (0) 1 45 21 04 11
e-mail: [email protected]
czech republic: www.armstrong.cz
hungary: www.armstrong.co.hu
romania: www.armstrong.ro
serbia: www.armstrong.rs
slovakia: www.armstrong.sk
slovenia: www.armstrong.si
duBAi - united ArAB eMirAtes
Armstrong Building Products L.L.C.
P.O. Box 73831
Tel.: +971 42 045 686
e-mail: [email protected]
www.armstrong.ae
Armstrong Plafonds Métalliques SA
Bureau Suisse Romande
3, rue Gustave-Moynier
1202 Genève
Suisse Romande
Tel. +41 (0) 22 731 60 70
Fax +41 (0) 22 731 60 74
■
Armstrong Metalldecken GmbH
Bundesstrasse 70
6830 Rankweil
Österreich
Tel +43 (0) 55 22 34 44-0
Fax +43 (0) 55 22 34 44-8
eAstern europe
cis
■ Armstrong World Industries
Park Place, office E502
# 113/1, Leninsky Prospekt
Moscow 117198
Russia
Tel.: +7 495 956 5100
Fax: +7 495 956 5101
e-mail: [email protected]
russian federation: www.armstrong.ru
■
frAnce & french speAking AfricA
Armstrong Building Products SAS
Bureaux Commerciaux France
Immeuble Paryseine
3 Allée de la Seine
94854 Ivry-sur-Seine
France
Tel: 0800 41 36 43 (appel gratuit)
Fax: +33 (0) 1 45 21 04 11
e-mail: [email protected]
www.armstrong.fr/plafonds
Siège social
Armstrong Building Products SAS
67 Rue de Salins
BP 89
25300 Pontarlier
France
■
■
gerMAny, AustriA & switZerlAnd
Armstrong Building Products
Kundenservice
Office Building Quadrium
Claudius Prinsenlaan 126
4818 CP Breda
Niederlande
Tel.: +49 0251 7603 210
Fax: +49 0251 7603 593
e-Mail: [email protected]
www.armstrong-decken.de
www.armstrong-decken.at
www.armstrong.ch
■
Armstrong Metalldecken AG
Kunklerstrasse 9
9015 St. Gallen
Switzerland
Tel. +41 (0) 71 313 63 63
Fax +41 (0) 71 313 64 00
■
Armstrong Metalldecken GmbH
Linzerstrasse 139
4600 Wels
Österreich
Tel. +43 (0) 72 42 56 901
Fax +43 (0) 72 42 56 901-75
■
Armstrong Metalldecken GmbH
Messendorferstrasse 6
8041 Graz
Österreich
Tel. +43 (0) 31 64 71 584
Fax +43 (0) 31 64 71 584-10
itAlie & grece
■ Armstrong Building Products
Ufficio Commerciale Italia
3 Allée de la Seine
94854 Ivry-sur-Seine - Francia
Tel.: N° verde 800.118.085
Fax: +33.145.21.04.11
e-mail: [email protected]
www.armstrong-soffitti.it
www.armstrong.eu
Sede Legale: Armstrong Building Products S.r.l
via delle Industrie 17
20040 Caponago (MB) Italia
P.IvA 12021150151
netherlAnds
■ Armstrong Building Products B.v.
verkoopkantoor Nederland
Office Building Quadrium
Claudius Prinsenlaan 126
4818 CP Breda
Nederland
Tel.: +31 076 521 77 33
Fax: +31 076 521 04 07
e-mail: [email protected]
www.armstrong.nl/plafonds
portugAl
Armstrong Floor Product
Rua de Manuel Assunçao de Falcao, 63
4475-041 Santa Maria de Avioso - Maia
Portugal
Tel.: +351 22 982 81 10
Fax: +351 22 982 81 19
[email protected]
www.armstrong.com.pt
■
spAin
Armstrong Building Products
Oficina de ventas España
Immeuble Paryseine
3 Allée de la Seine
94854 Ivry-sur-Seine
Francia
Tel.: + 34 91 642 04 99
00 800 90 21 03 68
Fax: +33 (0) 1 4521 04 11
e-mail: [email protected]
www.armstrong.es/techos
■
repuBlic of irelAnd
Armstrong World Industries Ltd.
108 Greenlea Road
Terenure
Co Dublin 6W
Ireland
Tel.: 1800 409002
Tel.: +353 1 499 1701
Fax: +353 1 490 7061
e mail: [email protected]
www.armstrong-ceilings.ie
■
united kingdoM
Armstrong World Industries Ltd
Building Products Division
Armstrong House
38 Market Square
Uxbridge UB8 1NG
Tel.: 0800 371849
Fax: +44 1895 274287
e-mail: [email protected]
www.armstrong-ceilings.co.uk
INSPIRATION
ENvIRONNEmENT
PRODUCTS
TECHNICAL DATA
CONTACT
■
Advisory note
All photographic and design elements supplied in this brochure do not necessarily reflect any recommendation by any of the companies named in this brochure as to
the proper use or recommended methods of installation of suspended ceilings and are supplied only as informative material. For technical reasons in printing, differences
may appear between colours printed in this brochure and the actual product. The choice of colours should always be made from a sample of the product. All statements
and technical information contained in this brochure, or any publication of the companies named in this brochure, relating to Armstrong ceilings are based on results
obtained under laboratory test conditions. It is the responsability of the user to verify with the seller of the products in writting that such statements and information are
appropriate to the specific use intended. Sales of the products and liability of the selling companies are in accordance with the terms and conditions of sale of the selling
company. All product specifications are subject to modifications without prior notice.
Px1104
Armstrong Building Products R.C.S. Besançon B 784 131 575
Printed in E.C.
This document is printed on paper that comes from sustainably managed forests. PEFC/10-31-945
Agency: EPCOM. © Nike Bourgeois, Miguel de Guzmán, Sandro Lendler, Simon Miles, Beppe Raso, Grigori Rassinier, Francisco Urruti, Gettyimages, Joao Morgado.
INSPIRATION
CONTACT
Discover inspirational
on-line tools such as the
‘Book of Idea’s’, European
project gallery, etc...
PRODUCTS
ENvIRONNEmENT
Browse the full portfolio
of Armstrong products
and solutions.
Learn about Armstrong
recycling programmes,
environmental initiatives &
policies...
TECHNICAL DATA
Full access to on-line
technical information such
as guide specifications,
acoustic and fire test
reports, CAD drawings
as well as brochures &
product datasheets.
E mail technical
questions or request
literature and samples
on-line, you can also find
an Armstrong Distributor
or Omega Contractor...
Also find...
our acoustical mini website or our Book of ideas.
www.armstrong.eu
THIS BROCHURE IS dIVIdEd INTO THREE SECTIONS:
1 > Ceiling information
To help define the right ceiling solution ________________________ 1
2 > Product information
detailed design and technical information for each product ______ 31
discover the Armstrong e-catalogue,
available on our website
3 > Installation
Armstrong's installation and maintenance recommendations ___ 136
www.armstrong.eu
1 > Ceiling information
ENVIRONMENT
6
PROjECT
GAllERy
ACOUSTICAl
COMFORT
SAFE &
HEAlTHy
INSTAllATION &
MAINTENANCE
2
10
20
24
12
22
Installation
& Maintenance
Armstrong Policy
& Initiatives
Project Gallery
7
Product Selector by
Suspension System
Sustainable Solutions
& Recycling
Programmes
8
End User Comfort
9
Awards
& Certifications
26
28
Product Selector
by Material
Cover
From Performance
to Acoustical Comfort
The Role of Ceilings
in Passive Acoustics
Fire
Technical Glossary
136
14
The Role of Ceilings
in Active Acoustics
Product Selector
by Performance
15
Cover
16
Product Selector
by Application
Health and
Cleanliness
Solutions for Retrofit
30
Product names index
(alphabetically)
Acoustical Technical
Glossary
17
Acoustical
Performance
1
PROjECT GAllERy
- Dubai Airport (UAE)
METAL Ceilings
TRANSPoRT
RETAIL - Concordia Hotel (IT)
AxIoM C Canopy
RETAIL - Wellness Park Laško (SL)
WooD Ceilings
oFFICE - Kinnarps (FR)
ULTIMA Canopy
HEALTHCARE - Refaja Ziekenhuis Hospital (NL)
ULTIMA Large module
2
EDUCATIoN
- Brede School Mikado-Aalsmeer (NL)
oPTIMA
EDUCATIoN - Luiss University (IT)
ULTIMA Canopy
3
PROjECT GAllERy
TRANSPoRT
HEALTHCARE - Bos & Lommer Drugstore (NL)
BIogUARD ACoUSTIC
- Nice Airport (FR)
oRCAL Canopy
- Newfield & Talbot (UK)
METAL CLIP-IN
EDUCATIoN
oFFICE - Fortis Bank (NL)
LAy-IN MicroLook (Metal)
www.armstrong-ceilings.co.uk/
inspirationzone
RETAIL - Bakery (D)
AxIoM C Canopy (Metal)
TRANSPoRT - gatwick Airport (UK)
LAy-IN AxAL Vector (Metal)
oFFICE - online (PT)
oPTIMA Canopy
4
5
ARMSTRONG POlICy
& INITIATIVES
DID You Know...
DID You Know...
Armstrong helped pioneer “green” practices from as early as 1860. Our commitment to environmentally
preferable products and programmes began more than a hundred years ago when the company
developed a process to recycle cork scrap. The end result was a product which was introduced then
and is known today, as linoleum.
raw material
Armstrong continually seeks to make use of research and production
technology to provide protection for the environment both in the workplace
and the wider community, reducing risk to our surroundings and natural
elements.
Raw materials for our ceilings are renewable and abundant in nature Biosoluble mineral wool (the wools used in our products meet the
classification “exempt” as defined by EC directive 97/69/EC 1997), perlite,
natural starch, recycled paper, recycled tiles and clay. None of our ceiling
products contain asbestos.
Armstrong keep reinvesting in ongoing product innovation to reduce
our environmental footprint.
energy management
In 1999, Armstrong Ceilings in
the United States introduced
the industry’s first ceiling
recycling programme. To date,
worldwide, we have recycled
over 8 million m2 of old ceiling
material. That’s more than
40,000 tonnes of construction
waste that’s been diverted from
landfills.
■ End-of-Life recycling
programme: we offers a free
collection programme for
refurbishment /strip out projects
of 2000m2+, of used tiles
whenever it is environmentally
and economically viable to do
so. The ceiling tiles are 100%
recycled into the mix and are
processed into new ceiling tiles.
■ off-Cut recycling
programme: in UK and France,
we offer an Off-Cut recycling
programme that diverts waste
during the installation process
from going to landfill.
6
latest information available on our website
Armstrong Ceilings can contain up to 82% recycled content.
We have the broadest portfolio of ceilings with high recycled content.
Armstrong suspension systems contain 25% recycled content – the
highest percentage of post consumer content in the industry.
ConCeption
new produCts
reCyCling programmes
SUSTAINABlE SOlUTIONS
Since 1998, Armstrong has been engaged in efforts such as our ‘gas
reduction project’ to focus on the control of energy use during product
manufacture. These programmes have, and continue to reduce energy use.
safety programmes
For Armstrong, safety is an ongoing key priority for our businesses,
and as a result, we have made several step changes in our processes,
procedures and measures to attain a world class safety performance.
logistiCs
As one of the worlds leading manufacturer's of suspended ceilings,
Armstrong has multiple manufacturing facilites, reducing transportation,
emissions and our environmental impact.
Over the many years that Armstrong has led the industry, we have
developed, in conjunction with our customers, packaging that utilises
minimum material, but ensures durability of the product during transport
and installation.
Mineral ceilings
High recycled content (up to 82%)
• High light reflectance and
acoustical performance
• 15 year guarantee
• Multiple manufacturing locations
for reduced transportation costs
& emissions.
■
•
Metal ceilings
High recycled content (up to 30%)
• Well established 3rd party recycling
waste stream
• 15 year guarantee
• High light reflectance and
acoustical performance
• Cleanable and durable
• Multiple manufacturing locations
for reduced transportation costs
& emissions
• design flexibility for waste
minimisation and performance
optimisation.
■
•
reCyCled Content
A significant proportion of our ceiling tiles are produced using recycled raw
materials, including slag mineral wool, other recycled mineral wools, recycled
paper and recycled ceiling tiles. These recycled contents are indicated on all
Armstrong’s published literature in accordance with EN ISO 14021 : 2001.
air Quality management
Armstrong is continually engaged in research and development efforts
to minimise the impact on air quality of our products.
In accordance with EN 13964, as part of the process for achieving the CE
mark, all Armstrong ceiling products attained the lowest classification E1.
produCts
Suspension Systems
All Armstrong suspension systems
contain 25% recycled content.
• Rotary stitched for additional
strength and stability
• Recyclable
• Patented Peakform for extra
strength & stability
• Multiple manufacturing locations
for reduced transportation costs
& emissions
■
%
reCyCled Content
CalCulated aCCording to iso 14021
Product Range
Mineral
OPTIMA
VISUAl
CIRRUS MAx / CIRRUS 75
PERlA dB
UlTIMA dB
SAHARA dB
BIOGUARd PlAIN
FINE FISSUREd + FF Black
GRAPHIS
COlORTONE dUNE
BIOGUARd ACOUSTIC
PERlA
PlAIN
•
Product Range
82%
71%
65%
63%
63%
61%
52%
51%
51%
48%
45%
45%
44%
UlTIMA
UlTIMA Vector
SAHARA Vector
PERlA OP
SAHARA MAx / SABBIA
UlTIMA OP
CERAMAGUARd
CIRRUS
CIRRUS design
NEEVA
PARAFON HyGIEN
SIERRA OP
Metal
Grid
44%
44%
43%
42%
42%
42%
38%
33%
33%
20%
20%
15%
30%
25%
*Recycled Content definition (from EN ISO 14021:2001):
Proportion, by mass, of recycled material in a product or packaging. This is consistent with WRAP «rules of
thumb» guidelines. Only pre-consumer and post-consumer materials shall be considered as recycled content,
consistent with the following usage of the terms.
Material diverted from the waste stream during a manufacturing process. Excluded is reutilisation of materials
such as rework, regrind or scrap generated in a process and capable of being reclaimed within the same process
that generated it.
Material generated by households or by commercial, industrial and institutional facilities in their role as end users
of the product which can no longer be used for its intended purpose. This includes returns of material from the
distribution chain.
Discover our
Environmental
brochure
7
ENd USER COMFORT
AWARdS & CERTIFICATIONS
DID You Know...
A ceiling with a high light reflectance, up to 90%, can extend the daylight into a space which
can help to reduce the lighting energy required. you can enhance the indoor environment by improving
the acoustics of the space.
Visual Comfort
aCoustiCal Comfort
thermal mass
The 'light reflectance' of a surface is
its ability to reflect light. daylight
and electrical lighting represent the
two primary sources of lighting
available in the workplace.
The light reflectance of the ceiling,
floor and wall surfaces play the
second most important role for
overall illumination of the room,
thus also directly affecting working
comfort and productivity.
In all types of spaces, choosing
the right acoustical solutions will
enhance the end user’ needs and
overall comfort. With acoustics,
you need to determine whether
intelligibility, concentration or
confidentiality is required? Armstrong
can help you find the right acoustic
solution for your space.
you can choose from a wide
portfolio of products such as
Armstrong canopies, standard
suspended ceilings and i-ceilings
sound masking products.
Armstrong acoustical ceilings reduce
noise levels in interior spaces,
allowing for an optimum balance of
high performance sound absorption
and room to room sound attenuation
to maximise / minimise speech
intelligibility as appropriate.
To control the thermal environment
in an office, we can use the thermal
mass of the concrete to control the
temperature in the room instead
of relying on air-conditioning and
heating. Without the need to power
these, the amount of electricity
being used is reduced significantly,
lowering the building’s energy
requirements.To enable the thermal
slab to work efficiently, it is important
to maximise the open area. Solutions
like canopies make it possible, still
improving acoustical and visual
comfort.
High light reflectance ceilings
also enhance indirect lighting by
improving overall lighting uniformity,
returning up to 90% of the light
back into the space, compared
to 75% with standard ceilings.
• A light reflectance of 90% and
more allows 20% of cost savings
with indirect lighting, and can yield
total building energy savings
up to 11%.
• Canopies installed in the work
place can improve the light
reflection over a working space
and provide better comfort for
the end user.
•
lifEtimE lifetime
guarantee
guarantee
15 YEAR 15 year
guarantee
guarantee
8
latest information available on our website
manufaCturing
aCCreditations
Armstrongs’ corporate policy includes
an ongoing commitment to improving
its environmental responsibilities by
starting with a comprehensive safety
policy and continuing through into
the environment. Not only are we
continuing to make our products
environmentally friendly but we are
also using effective recycling methods
to prevent pollution and reduce waste.
Our certifications:
The result of continuous
product line development and
improvement allows us to offer
a new lifetime guarantee for
our SAHARA, SAHARA dB and
SAHARA MAx / SABBIA product
ranges.
discover our Book of “Green” Ideas
on our webiste
Armstrong Headquarters, US
LEED-EB Platinum building
Most of our products are
cleanable and our hygiene tiles
have an antifungicide treatment.
The durability of our products
means less damage and
fewer replacements required,
resulting in a lower impact on
the environment. All our 95%
and 99% RH products are
guaranteed for 15 years.
ISO 14001: 2004
ISO 9001: 2008
OHSAS 18001: 2007
produCt CertifiCation,
aCCreditation - Bre (uK)
As the worlds foremost producer of
suspended ceiling systems, we know
how important it is to be transparent
in regard to the impact our operations
have on the environment.
Claims are easy to make but difficult
to substantiate without an independent,
universal measuring system.
BRE initiated a scheme compliant
with ISO 14041 which provides
Environmental Profiling, allowing
end users and manufacturers
to assess the environmental
performance of selected products.
Starting in 2004 we commissioned
BRE to profile our UK ceiling and grid
manufacturing facilities and products.
BRE assess this impact using an
‘Ecopoint’ score based on a product’s
raw materials and manufacturing
processes. These are then measured
against key criteria, including climate
change, mineral extraction, ozone
depletion and waste generation. Our
rating was 0.16 Ecopoints giving a
lower environmental impact compared
with BRE’s generic norm of 0.22
(based upon 1m2 of 600 x 600 ceiling
panel and Trulok grid). At that time
the “Green Guide to Specification”
included suspended ceilings and
this resulted in an ‘A’ rating – the best
available.
BRE’s system of profiling has since
progressed to reflect the needs of
developing European and International
standards. It now complies with
ISO 21930, the forthcoming standard
for analysing the impacts of
construction products. Therefore,
during 2007 we updated our
Environmental Profile using BRE’s
new methodology and are delighted
that our Ecopoints rating of 0.16 has
reduced to 0.10 Ecopoints.
produCt CertifiCation,
aCCreditation - fdes (fr)
Until a standardised method for
profiling products is agreed within
the European Union, there will
be many approaches to better
understand the environmental impact
of products. An approach used in
France, that is currently expected
to mirror a European approach is
through the development of FdES
(Fiche déclaration Environnementale
et Sanitaire). The information
generated through this procedure
is utilised in the HQE (Haute Qualité
Environnementale) project
accreditation approach. Armstrong
has developed product profiles for
Mineral & Metal tile facilities in line
with the FdES methodology.
other CertifiCations
■ IBu: WETEC (which Armstrong
is a member of) is a certified partner
for sustainable building and member
of www.bau-umwelt.com
IBU Institut Bauen und Umwelt
e. V. (German Institute Construction
and Environment e. V.). An EPd
Environmental Product declaration
for WETEC products is on its way.
■ LEED: US Green Building Council
is an organisation with the goal
of making sustainable buildings
universally available within a generation.
The USGBC’s leadership in
Energy and Environmental design
(lEEd) building certification system
provides a framework by which the
environmental footprint of all aspects
of building design, construction
and operation can be measurably
improved.
Today, Armstrong is proud to
have joined the uK Green Building
Council. Armstrong is a founding
member of the United States and
the Indian Green Building Councils
and is also a member in Canada,
China and Australia.
Armstrong’s corporate headquarters
building in lancaster, PA, was
certified in 2007 as lEEd-EB (Existing
Building) Platinum, the highest
and most difficult rating to achieve.
9
ACOUSTICAl COMFORT:
From performance to acoustical comfort
examples of most appropriate aCoustiCal solutions:
DID You Know...
Acoustical treatment is not always sound absorption.
The right acoustical environment is essential and the way to achieve this is to focus on:
■ Intelligibility (I want to be understood),
■ Confidentiality (I do not want to be overheard),
■ Concentration (I do not want to be disturbed).
Situation
Product performance
& attributes
Intelligibility
Mix of
absorption
& attenuation
uLtIMA
PERLA
SAHARA MAX
/SABBIA
- Meeting room
- Classroom
- Conference room
intelligiBility,
Confidentiality
and ConCentration
what influenCes performanCe?
Confidentiality
Attenuation
PERLA dB
uLtIMA dB
SAHARA dB
The acoustical properties of a mineral ceiling tile vary depending on the
combination of porosity, thickness and density. The following table shows
the impact on acoustical performance when increasing each of these
parameters.
I do not want
to be overheard
- Closed Office
- Hospital bedroom
Absorption
oPtIMA,
uLtIMA oP
PERLA oP
SAHARA MAX
/SABBIA
- Open spaces
- Call centre
- library
To meet acoustical regulations,
it is generally sufficient to provide
the performance measures in
unoccupied spaces, without
office equipment switched on.
Acoustical regulations usually
recommend values to be achieved
for reverberation times (within
a space) and sound insulation
(between spaces or from outside
the building).
This approach isn’t satisfactory any
more to meet the expectations
of occupants, in particular with
the development of open spaces
in offices and the increasing hearing
problems of students in the
education sector.
On a day-to-day basis, any activity
disturbs the initial acoustical
balance, as for example group
discussions, ringing phones, copier
machines, music, open windows
or road traffic noise.
Occupants of an office, a classroom,
a shop, a hospital or any other
space, need a comfortable and
healthy environment to carry
out their activity under the best
conditions.
The acoustic quality of a room
in a building is governed by major
design criteria which require close
monitoring:
■ Intelligibility
(I want to be understood),
■ Confidentiality
(I do not want to be overheard),
■ Concentration
(I do not want to be disturbed).
10
latest information available on our website
I want to be
understood
Concentration
Sound absorption
I do not want
to be disturbed
Sound attenuation
and reduction
Product recommendation
better
good
best
Examples
of room types
Density
Porosity
a wide range of solutions
thickness
Acoustical solutions to answer all performance requirements. Ceiling tile edge details have an important influence in
helping to prevent noise transfer from one space to another.
Armstrong offers a wide range of densities and materials combining
the necessary acoustical performances with an extensive range of visuals.
The impact of acoustical control on occupants of spaces with passive
ceilings can be summarised as follows:
Absorption a w
1,00
0,80
0,70
0,60
Sound
absorption
Sound attenuation
and reduction
Controls
Reflections within rooms
Transmission between rooms
Effect upon
Intelligibility
Confidentiality & Concentration
Benefits
Room occupants
Room neighbours
0,90
0,90
0,60
0,60
0,65 0,65(H)
0,70(H) 0,70(H)
0,90
0,95
1,00
1,00
26
27
0,75(H)
0,60
0,65(H)
0,60 0,60(H)
0.60(H)
0.50(H)
0,50
OP
0,00
0
10
20
30
40
50
0,95
Standard
dB
34
39
35
36
36
40
34
26
29
25
27
39
40
41
41
43
43
r
2
2
2
2
2
2
2
A
P
P
A
P
A
B
B
B
A
o
I
L
L
L
L2
L
L
t
d
d
d
R
M
B
S
c
S
I
R
B
A
A
A o P SL RLA o oP SL IMA o oP SL
HA
BS
B S LA
BS
PE
SA
RA
ULT TIMA MA Ve HAR
SA
E
A d PER RLA d ULTIM IMA d SIERR RA o
A
A
LT
HA
x/
P
L
A
I
L
R
U
M
A
A
T
I
S
A
U
R
R
S
M
H
UL
PE
PE
ULT
SIE
ULT
SA
RA
HA
SA
Attenuation dnfw
For a more detailed explanation,
and to download the 'Armstrong
Acoustic Guide' brochure, visit
our dedicated website
aCtiVe or passiVe aCoustiCs?
For a balanced acoustic environment, Armstrong recommends a two step approach:
1 ■ use passive acoustics
• to absorb sound within a space and block sound between spaces or coming from outside the building.
2 ■ use active acoustics
• to cover remaining un-wanted noise
• to raise the level of speech and overcome intelligibility issues
• to play music
• to provide intelligible public announcement.
11
ACOUSTICAl COMFORT:
The role of ceiling in passive acoustics
DID You Know...
Suspended ceiling systems play a key role in the control of the acoustical environment.
Passive acoustics is concerned with the absorption and blocking of sound within and between spaces.
■
■
■
■
12
Sound attenuation is the control of sound
transmission between adjacent spaces with
a common void above them.
sound attenuation
for Better Confidentiality
Case study:
ConfIDEntIALItY
Many areas, such as senior management offices
and medical consulting rooms, require high levels
of room-to-room insulation for optimal aural privacy.
Armstrong’s dB range of higher-density ceilings minimises
noise transfer between rooms by as much as 43 dB,
keeping conversations private and occupants happy.
How to ensure noises from adjacent spaces are not
heard in the corridor ?
■
De Koning office (nL)
■
Solution:
How to create a quiet space despite noisy
services in the plenum?
■
International Book Club (E)
■
Solution:
Sound reduction is the control of sound
generated in the plenum or coming from the floor
above.
uLtIMA dB Planks
sound aBsorption
for Better ConCentration
Case study:
ConCEntRAtIon
Sometimes the goal is simply to reduce noise transfer as
much as possible, for example in large open offices and
call centres, where voices, telephones and office equipment
can cause major distractions. Armstrong’s OP range of
lower-density ceilings controls excessive sound reflections,
offering customers optimal levels of sound absorption.
How to provide concentration, visual comfort and
easy access to the plenum in an open space?
■
Recicladhor office Building (E)
■
Solution:
MEtAL Premium B15
How to improve the acoustic, visual and ergonomic
comfort of an open plan television studio?
■
I online office (Pt)
■
Solution:
Sound absorption is the part of incident sound
that is not reflected by the tile.
Balance of sound attenuation and absorption.
latest information available on our website
uLtIMA Vector
sound attenuation & aBsorption
for Better intelligiBility
Case study:
IntELLIGIBILItY
Controlling sound absorption and sound reduction is
vital for improving speech clarity. Armstrong’s standard
range of medium-density ceilings strikes an outstanding
balance between both, blocking unwanted noise from
outside while enhancing sound quality inside. These ceilings
are ideal for classrooms and conference rooms.
How to provide the best acoustic design solutions
to a class room?
■
School (D)
■
Solution:
uLtIMA Board
oPtIMA Canopy
How to provide optimal intelligibility to all
participants in a meeting room?
■
Armstrong Building Product office (fR)
■
Solution:
oRCAL Canopy (Metal)
13
ACOUSTICAl COMFORT:
ACOUSTICAl COMFORT:
The role of ceiling in active acoustics
Solutions for "RETROFIT"
DID You Know...
what is "retrofit"?
DID You Know...
Armstrong’s i-ceilings provide the active acoustics to complement
the passive treatment whenever necessary.
Acoustical retrofit solutions by
Armstrong offer unique benefits:
■ Aesthetics: create a striking
design and more intimate
spaces.
■ flexibility: solutions can be
easily displaced to suit future
reconfigurations.
■ functionality: act as light
reflectors to minimise energy
consumption.
■ Ease of installation: special
direct ceiling attachment
(plasterboard and grid) with
OPTIMA Canopy.
definition
i-ceilings sound panels are a range
of state-of-the-art flat panel
loudspeakers designed to
aesthetically match Armstrong
ceiling tiles and lay directly into
the ceiling grid.
Sound panels deliver voice,
music and active acoustics,
an electroacoustical room treatment
that enhances intelligibility,
confidentiality and concentration
levels in occupied spaces.
An acoustical retrofit consists of fine
tuning the acoustical performance
of an existing space to meet the end
users' desired levels of intelligibility,
concentration and confidentiality.
When relocating a business to new
premises or reconfigurating an existing
office plan to suit new organisational
requirements, acoustics must be taken
into account as early as possible in
the design process. Integrating
acoustics and space planning will
allow to achieve a good balance
between space optimisation and
occupants' comfort levels for more
productive working environments.
The acoustical performance of a
space is set by its size, the room
surface materials, furniture and
background noise. An acoustical
retrofit will therefore consider:
• changing existing surface materials;
• complementing the existing room
configuration with discontinuous
ceiling solutions (Canopy range);
• complementing the passive
acoustics with an active acoustics
solution (i-ceilings)
Office space planning is a balance
between optimising the area
available and producing a comfortable
and productive working environment.
Armstrong recommends that acoustical
fine tuning be considered as early
as possible in the design scheme.
standard edge details
Canopy : the armstrong solution
Sound panel
edge detail
Ceiling
edge detail
Grid
Board visual
where ceiling tiles and
grids are at the same level
tegular visual
for a ceiling with depth
on a wide grid
MicroLook visual
for a ceiling with depth
on a narrow grid
Sound panel
edge detail (1)
Microlook
Tegular
Microlook
Grid
24 mm
24 mm
15 mm
(1) Available in VECTOR, AxAl & ClIP-IN (microperforation and standard perforation)
Plasterboard ceilings or exposed
concrete soffits can create a
very reverberant space which, in
combination with today's office interior
design trends with extensive use
of glass partitions, impacts negatively
on concentration levels.
Existing suspended ceilings do not
always meet the stringent acoustical
requirements set by such applications
as call centres. Treating sound directly
above workstations, whilst also
contributing to lowering the overall
reverberation time, is then key to
enhancing levels of concentration and
confidentiality.
Under challenging architectural and
acoustical configurations, retrofitting
an existing ceiling with lightweight and
design acoustical absorbers
or "canopies", can trigger a 180
degree shift in the perceived quality
of the space, higher comfort levels
and an increase in occupant
productivity.
Canopy solutions may further
be complemented by wall treatments
and active acoustics by Armstrong.
appliCations
Transport
Retail
14
Sound
masking
Open space, call centre
✔
Individual office
✔
Conference room
✔
Class room
✔
✔
Public
announcement
Music
Acoustical performance objective:
Speech intelligibility with a Rt<0,8s
3
✔
Room volume
Ceiling height
Area
length
Width
2,5
✔
✔
✔
library
✔
✔
Waiting area
✔
✔
Patient room
✔
✔
Shop / Showroom
✔
✔
Restaurant
✔
✔
lounge
✔
✔
Waiting room
✔
✔
latest information available on our website
Example of acoustical treatment in an empty space:
Reverberation Time (secondes)
Healthcare Education
Office
Speech
reinforcement
2
250
2,6
96,2
12,0
8,0
m3
m
m2
m
m
1,5
Empty room
1
13 UlTIMA Canopy
20 OPTIMA Canopy
0,5
14 ORCAl Canopy (Metal)
5 AxIOM Canopy (with UlTIMA OP)
0
125
250
500
1 000
2 000
4 000
Octave Band centre frequency (Hz)
15
ACOUSTICAl
TECHNICAl GlOSSARy
ACOUSTICAl
PERFORMANCE
weighted sound aBsorption CoeffiCient, a w
weighted sound reduCtion index, rw
Sound reduction
A single-number rating for random incidence sound
absorption coefficients calculated by reference to EN
ISO 11654. With this method measured values obtained
in accordance with EN ISO 354, are converted into
octave bands at 250, 500, 1000, 2000 and 4000Hz
and are plotted onto a graph. A standard reference
curve is then shifted towards the measured values in
steps of 0.05 until a “best fit” is obtained. The derived
value of a w will vary between 0.00 and 1.00 but is only
expressed in multiples of 0.05, eg a w = 0.65.
A single-number rating of the laboratory measurement
of (vertical) airborne sound reduction of a suspended
ceiling. It is determined by reference to EN ISO 717-1
from measurements of sound reduction index made in
accordance with EN ISO 140-3.
shape indiCator
With reference to EN ISO 11654, the calculated value of
a w may be qualified by one or more letters (in brackets)
to indicate if the product has excess sound absorption
at low (L), medium (M) or high (H) frequencies.
sound aBsorption Class
With reference to EN ISO 11654, the calculated value
of a w may additionally be allocated into one of six
descriptive classes in accordance with the following
table:
The laboratory measurement of the sound intensity
in a room below a roof construction when subjected
to rainfall. It is determined by reference to EN ISO
140-18:2006 – laboratory measurement of sound
generated by rainfall on building elements. The roof’s
performance can be tested with or without a suspended
ceiling beneath. The intensity of the rainfall tested can
be selected from the options given in the standard.
A combined A-weighted single-number (lIA) can also
be determined.
sound attenuation
A term used in relation to the horizontal transmission
of sound through a suspended ceiling above adjacent
rooms sharing a common ceiling plenum.
Sound absorption Class
aw
sound reduCtion
A
0,90; 0,95; 1,00
A term used in relation to the vertical transmission
of sound through a suspended ceiling.
B
0,80; 0,85
C
0,60; 0,65; 0,70; 0,75
d
0,30; 0,35; 0,40; 0,45; 0,50; 0,55
E
0,15; 0,20; 0,25
Not Classified
0,00; 0,05; 0,10
weighted suspended Ceiling normalised
leVel differenCe dncw
A single-number rating of the laboratory measurement
of room-to-room (horizontal) airborne sound insulation
of a suspended ceiling above adjacent rooms sharing a
common ceiling plenum. It is determined in accordance
with EN ISO 717-1 from measurements made in
accordance with EN 20140-9.
Note: EN 20149-9 has now been withdrawn and superseded
by EN ISO 10848-2. (see dnfw), although dncw test results still
continue to be valid.
weighted suspended Ceiling normalised
flanKing leVel differenCe, dnfw
A single-number rating of the laboratory measurement
of room-to-room (horizontal) airborne flanking sound
transmission of a suspended ceiling above adjacent
rooms sharing a common ceiling plenum. It is
determined in accordance with EN ISO 717-1 from
measurements made in accordance with EN ISO
10848-2. This has now superseded EN 20149-9.
(see dncw).
16
rain noise sound intensity leVel, li
latest information available on our website
noise reduCtion CoeffiCient, nrC
A single-number descriptor of random incidence sound
absorption coefficients. defined in ASTM C423 as the
arithmetical average, to the nearest multiple of 0,05,
of the measured sound absorption coefficients for the
four one-third octave band centre frequencies of 250,
500, 1,000 and 2,000 Hz.
saBine
A Sabine is a measure of the total sound absorption
provided by discrete (canopies, screens, furniture, etc)
objects when installed in an architectural space. Because
these type of absorbers have more than one surface and
may be irregular in form, it is not meaningful to assign
sound absorption coefficients to them. Hence Sabines
per unit is preferred to characterise the absorption
provider by an individual 'space absorber'.
Product Name
Cert #
NEEVA 15
OPTIMA 15
PERlA OP
UlTIMA OP
SIERRA OP
SAHARA MAx / SABBIA
SAHARA
BIOGUARd ACOUSTIC
PERlA
UlTIMA
BIOGUARd PlAIN
SAHARA dB
UlTIMA dB
PERlA dB
5915
5916
5919
5921
5920
5923
5925
5927
5928
5931
5926
5934
5935
5932
weighted
value Rw
7
7
10
10
11
17
17
18
18
18
19
20
21
21
One-Third Octave Band Centre Frequency Hz
Mineral range
100
125
160
200
250
315
400
500
630
800
1000 1250 1600 2000 2500 3150 4000 5000
8,5
7,2
10,2
10,5
11,3
12,1
12,2
11,4
11,6
12,0
12,3
13,8
13,6
14,8
6,2
6,1
7,2
7,7
7,8
8,5
8,4
9,3
9,8
9,8
9,3
9,8
10,4
11,1
5,3
6,3
7,4
7,3
7,5
7,1
8,0
8,8
9,1
9,7
8,0
9,5
11,1
11,0
4,5
5,1
5,7
6,4
5,8
7,5
6,6
8,9
9,3
9,3
8,5
9,6
11,4
11,5
5,0
4,2
5,9
5,6
6,4
7,9
7,9
9,7
9,2
9,1
9,7
11,3
11,6
11,8
3,5
3,1
6,2
5,8
6,9
9,8
10,3
10,6
11,0
10,9
11,5
12,7
13,3
13,4
4,3
4,8
6,8
6,5
7,1
10,1
10,5
11,2
11,4
11,0
11,5
12,9
13,9
13,7
6,1
5,9
7,9
7,8
8,8
12,4
12,7
13,5
14,3
13,9
13,7
15,7
16,1
16,5
6,3
6,0
8,0
8,7
9,2
15,0
15,3
15,9
16,5
16,1
16,0
17,5
18,2
18,3
6,5
6,3
9,0
9,0
9,5
17,2
16,9
17,5
17,7
17,9
17,9
19,8
20,3
20,0
6,9
6,8
10,0
9,7
10,3
18,5
18,2
19,1
18,6
19,2
19,4
20,9
21,8
21,5
6,7
6,7
9,6
10,0
11,3
19,8
19,4
20,5
19,8
20,0
20,4
21,2
22,2
22,4
7,4
7,2
10,8
11,1
12,4
21,6
20,7
21,9
21,0
21,1
21,7
22,3
23,5
23,5
8,4
8,0
12,3
12,2
13,6
23,1
22,5
23,8
23,2
22,9
23,1
24,2
26,0
25,6
8,7
8,5
13,5
13,8
14,8
23,5
22,9
24,7
23,5
24,3
23,6
25,9
27,4
26,9
9,5
8,9
14,3
14,2
15,9
23,5
22,8
24,8
19,2
21,1
23,6
27,5
26,1
28,5
9,8
9,6
15,2
15,6
17,3
24,3
23,0
24,2
21,1
21,6
22,4
29,1
25,7
29,9
9,8
9,3
14,2
15,5
17,0
23,1
21,9
23,3
26,8
26,9
21,0
28,7
28,9
28,8
Metal range
Product Name
Cert #
Microperforation without fleece
Standard perforation without
fleece*
Microperforation with fleece
Standard perforation with fleece*
Microperforation with B15
Standard perforation with
B15*
PlAIN (no infill)
PlAIN with B15
5938
weighted
value Rw
5
4,8
4,8
4,5
5,0
4,8
4,6
4,6
3,8
5938
5
7,3
5,0
4,5
3,8
3,6
3,3
3,8
4,1
4,5
5,2
4,8
4,8
4,5
5,0
4,8
4,6
4,6
3,8
5939
5939
5941
6
6
18
9,0
9,0
11,7
6,9
6,9
9,1
5,6
5,6
7,9
5,2
5,2
9,5
5,3
5,3
10,1
4,0
4,0
11,8
4,6
4,6
11,7
5,9
5,9
13,8
6,1
6,1
16,3
6,4
6,4
18,0
6,3
6,3
18,5
6,0
6,0
19,6
5,8
5,8
20,7
6,4
6,4
21,9
6,7
6,7
22,5
7,0
7,0
23,2
6,7
6,7
24,3
6,2
6,2
25,1
5941
18
11,7
9,1
7,9
9,5
10,1
11,8
11,7
13,8
16,3
18,0
18,5
19,6
20,7
21,9
22,5
23,2
24,3
25,1
5936
5937
19
21
12,4
13,5
9,5
10,6
8,9
10,1
9,3
10,1
10,5
11,2
12,7
13,1
11,9
13,6
14,1
16,5
16,6
19,0
18,4
21,0
19,3
22,2
20,8
22,9
22,2
23,5
23,8
25,6
24,9
26,4
25,4
26,6
22,4
24,4
20,8
23,1
100
125
160
200
250
315
400
500
630
800
7,3
5,0
4,5
3,8
3,6
3,3
3,8
4,1
4,5
5,2
1000 1250 1600 2000 2500 3150 4000 5000
* Estimated
1) All SRI tests have been conducted in an independent third party quality assured laboratory in accordance with EN ISO 140-3 with the ceiling suspended horizontally
between two vertical transmission suites. Mineral tiles were 600x600 Board (square) edge in a Prelude T24 grid.
2) Rw values are determined in accordance with EN ISO 717-1.
3) Values for Standard Perf (16% open area) are estimated as being not less than Micro Perf (22% open area).
4) Armstrong conducts extensive and regular acoustic tests on its ceiling tiles and planks. Inevitably slight variations occur over a range of results for the same product.
The results above do not necessarily represent the highest achieved but indicate values that can be consistently and confidently offered.
Rain noise - the acoustic performance of Armstrong ceilings with a lightweight roof construction
EN ISO 140-18:2006 is a test method for determining the sound
intensity level of a radiating surface due to rainfall. Armstrong
tested a lightweight roof construction, with ‘heavy’ intensity rain
as defined in the standard, and then re-tested with a suspended
ceiling below. different ceiling tiles were tested and the results are
shown in the table below. The performance values given below
show the intensity of sound radiating into the room below the roof
(and ceiling) constructions. Therefore, unlike dnfw and Rw data,
where the higher the value the better insulation provided, the best
performing ceiling tiles are those which have the lowest intensity
levels, as less sound energy has penetrated into the room below.
The results shown give the combined performance of the roof
and ceiling constructions. Any change in the roof construction
performance will affect the combined roof and ceiling
performance. We have therefore shown the improvement
in dB that each of the ceiling tiles provided compared to
the roof construction on it’s own.
One-Third Octave Band Centre Frequency Hz
Product Name
Roof Construction
+ PERlA dB
Roof Construction
+ METAl Plain with B15 infill
Roof Construction
+ SAHARA MAx/SABBIA
Roof Construction
+ PERlA
Roof Construction + METAl
Microperforated with B15 infill
Roof Construction
+ PERlA OP
Roof Construction only
Cert #
C/21102
/R01 - 2
C/21102
/R01 - 4
C/21102
/R01 - 8
C/21102
/R01 - 6
C/21102
/R01 - 5
C/21102
/R01 - 10
C/21102
/R01 - 1
weighted Improve 100
value LIA -ment lIA
125
160
200
250
315
400
500
630
800 1000 1250 1600 2000 2500 3150 4000 5000
41.8
11.8
42,7 42,2 43,6 41,2 39,5 37,2 36,9 35,6 34,7 33,6 29,5
27,4
24,9
20,8
20,1
18,8
17,7
17,4
42.4
11.2
43,7 41,9 43,0 40,7 39,4 37,6 38,0 36,4 35,4 33,9 30,2
27,6
26,0
23,8
24,3
23,3
23,5
22,6
42.8
10.8
43,4 44,0 45,4 42,5 39,8 38,4 38,2 36,7 35,4 34,4 30,6
27,6
25,2
21,3
21,3
21,1
19,9
19,0
42.9
10.7
43,5 43,7 44,8 41,7 40,5 38,2 38,6 36,3 35,7 34,4 30,5
27,7
26,0
22,6
23,3
23,7
22,4
19,6
43.3
10.3
44,3 43,8 44,8 42,4 40,2 39,1 38,7 36,5 36,1 35,6 31,6
28,6
26,8
23,3
23,4
22,7
22,5
21,1
47.7
5.9
45,0 46,8 47,5 44,3 43,0 42,6 42,9 42,5 41,4 40,8 36,5
33,7
31,3
27,1
26,8
26,2
25,8
21,1
53.6
n/a
52,0 51,8 53,3 49,8 46,9 46,1 46,3 47,1 47,4 46,8 43,2
40,9
39,9
36,4
36,6
36,4
36,5
33,9
1) All tests have been conducted in an independent third party quality assured laboratory in accordance with EN ISO 140-18(2006).
2) The one-third octave band intensity values given are unweighted measurements in dB.
3) The roof construction was a 158mm deep profiled steel liner tray with 200mm insulation and an aluminium standing seam waterproof membrane.
4) The ceiling void depth between the top of the liner tray and the reverse of the ceiling tiles varied between 400mm and 700mm due to the pitch of the roof.
5) Armstrong conducts extensive and regular acoustic tests on its ceiling tiles and planks. Inevitably slight variations occur over a range of results for the same product.
The results above do not necessarily represent the highest achieved but indicate values that can be consistently and confidently offered.
17
ACOUSTICAl
PERFORMANCE
Sound attenuation
Sound absorption
Octave Band Centre Frequency Hz
Mineral and wood range - ap
Cert #
aw
Absorption
Class
NRC
125
250
500
1000
2000
4000
NEEVA 15
NEEVA 18 (Board)
OPTIMA 25
OPTIMA VECTOR 22
UlTIMA OP
OPTIMA 20
PARAFON HyGIEN 18
PERlA OP (Tiles & Board Planks)
PERlA OP Concealed Planks
VISUAl V49 + Fleece + 25mm x 20kg/m3 glass fibre
overlay
NEEVA 18 (Tegular & Microlook)
OPTIMA 15
SIERRA OP
UlTIMA VECTOR
CIRRUS MAx / CIRRUS 75
UlTIMA (Tiles & Mlook Planks)
UlTIMA Concealed Planks
PERlA
UlTIMA dB
SAHARA MAx / SABBIA
SAHARA VECTOR
BIOGUARd ACOUSTIC
FINE FISSUREd / FINE FISSUREd BlACK
PERlA dB
SAHARA (Tiles & Planks 15mm)
SAHARA Board Planks (17mm)
SAHARA dB
UlTIMA dB Concealed Planks
CERAMAGUARd
dESIGN CIRRUS
CIRRUS
COlORTONE dUNE
CONTRAST Circles, Square
MAdERA A12
PERlA dB Planks
VISUAl V49 + Fleece
MAdERA A1
MAdERA A8
MAdERA A10
MAdERA A2
BIOGUARd PlAIN
GRAPHIS (all face patterns)
PlAIN
ClEAN ROOM Fl
NEWTONE Residence
SAHARA (unperforated)
4527
3003
2914
2923a
4765a
2913
2998
4763a
5157
4360
1.00
1.00
1.00
1.00
1.00
0.95
0.95
0.95
0.95
0.95
A
A
A
A
A
A
A
A
A
A
0,95
0,95
1,00
0,95
0,95
0,95
0,95
0,90
0,90
0,90
0,40
0,40
0,50
0,35
0,55
0,40
0,40
0,50
0,45
0,35
0,90
0,85
0,85
0,80
0,85
0,80
0,85
0,85
0,85
0,80
1,00
1,00
1,00
1,00
1,00
1,00
0,90
0,95
0,95
0,95
0,90
0,90
0,95
0,90
0,95
0,85
0,90
0,90
0,90
0,90
1,00
1,00
1,00
1,00
1,00
1,00
0,95
1,00
0,95
1,00
1,00
0,95
1,00
1,00
1,00
1,00
0,90
1,00
1,00
1,00
3005
2912
5973
5711
3597
4687
4894a
4995
5546a
4362
5764
4949a
4441
5478a
4553
4486a
5541a
4484a
2921a
2929a
3023
3948
3255
5443
5968
4347
5442
5445
5444
5441
2945a
3253
3116
3352
3349
3426
0.90
0.90
0.90
0.75(H)
0.70(H)
0.70(H)
0.70(H)
0.65(H)
0.65(H)
0.65
0.65
0.60(H)
0.60(H)
0.60(H)
0.60
0.60
0.60
0.60(H)
0.55(MH)
0.55(H)
0.55(H)
0.55
0.55
0.50(L)
0.50(H)
0.50(H)
0.45(L)
0.35(L)
0.35(LM)
0.20(L)
0.15(L)
0.15(L)
0.15(L)
0.10(L)
0.10(L)
0.10(L)
A
A
A
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
d
d
d
d
d
d
d
d
d
d
d
E
E
E
E
-
0,85
0,90
0,85
0,70
0,75
0,70
0,70
0,70
0,70
0,65
0,65
0,60
0,60
0,65
0,55
0,55
0,55
0,55
0,60
0,55
0,50
0,55
0,50
0,60
0,50
0,50
0,45
0,45
0,50
0,20
0,15
0,15
0,15
0,10
0,10
0,15
0,40
0,35
0,50
0,50
0,40
0,55
0,50
0,35
0,40
0,50
0,45
0,35
0,40
0,30
0,45
0,35
0,35
0,30
0,25
0,35
0,35
0,40
0,40
0,45
0,30
0,10
0,40
0,40
0,45
0,35
0,30
0,35
0,30
0,25
0,25
0,30
0,75
0,75
0,75
0,55
0,40
0,50
0,50
0,40
0,40
0,55
0,50
0,40
0,40
0,40
0,40
0,45
0,40
0,35
0,30
0,40
0,40
0,40
0,40
0,70
0,35
0,30
0,60
0,60
0,60
0,30
0,20
0,20
0,25
0,15
0,15
0,20
0,85
1,00
0,85
0,70
0,70
0,65
0,60
0,60
0,60
0,75
0,60
0,50
0,55
0,55
0,55
0,60
0,55
0,55
0,50
0,45
0,45
0,50
0,45
0,70
0,40
0,40
0,55
0,55
0,60
0,20
0,15
0,10
0,15
0,10
0,10
0,10
0,85
0,80
0,85
0,85
0,90
0,80
0,75
0,85
0,80
0,75
0,70
0,70
0,75
0,70
0,65
0,65
0,65
0,65
0,80
0,60
0,55
0,60
0,55
0,55
0,60
0,50
0,45
0,40
0,40
0,15
0,10
0,10
0,10
0,10
0,10
0,10
0,95
0,90
1,00
0,95
1,00
0,90
0,90
0,95
0,95
0,70
0,70
0,85
0,75
0,85
0,65
0,55
0,65
0,75
0,85
0,75
0,60
0,55
0,60
0,45
0,70
0,75
0,35
0,30
0,30
0,15
0,20
0,15
0,15
0,10
0,10
0,10
0,95
0,95
1,00
0,95
1,00
0,85
0,95
1,00
1,00
0,45
0,55
0,90
0,75
0,95
0,60
0,45
0,65
0,85
0,75
0,85
0,70
0,45
0,65
0,40
0,80
0,90
0,35
0,20
0,25
0,15
0,25
0,25
0,25
0,15
0,05
0,20
Octave Band Centre Frequency Hz
Metal range - ap
Product Name
Cert #
aw
Class
NRC
125
250
500
1000
2000
4000
Microperforation with fleece
Standard perforation with fleece
Extra Microperforation with B15
Standard perforation with B15
Microperforation with B15
Extra Microperforation with fleece
PlAIN (no infill)
2175
l/2463
2334
2340
2337
2253
2206
0.75
0.70(L)
0.65
0.60(H)
0.60(H)
0.55(L)
0.10(L)
C
C
C
C
C
d
-
0,80
0,70
0,60
0,60
0,60
0,65
0,10
0,30
0,40
0,40
0,40
0,40
0,45
0,25
0,75
0,75
0,45
0,45
0,40
0,75
0,15
0,90
0,65
0,55
0,50
0,50
0,70
0,10
0,65
0,65
0,70
0,65
0,65
0,55
0,10
0,75
0,75
0,80
0,75
0,75
0,55
0,10
0,80
0,75
0,70
0,90
0,90
0,45
0,10
1) All tests have been conducted in an independent third party quality assured
laboratory in accordance with EN ISO 354 and with the ceiling installed over a
200mm cavity.
2) aw & NRC values are determined in accordance with EN ISO 11654 & ASTM
C423 respectively.
18
latest information available on our website
One-Third Octave Band Centre Frequency Hz
Mineral range
Product Name
3) Armstrong conducts extensive and regular acoustic tests on its ceiling tiles and
planks. Inevitably slight variations occur over a range of results for the same
product.
The results above do not necessarily represent the highest achieved but indicate
values that can be consistently and confidently offered.
Product Name
Cert #
weighted
value
4175a
44
4522f
5492a
43
41
4177a
100
125
160
200
250
315
400
500
630
800
1000 1250 1600 2000 2500 3150 4000 5000
dnc
20,8
27,6
28,9
33,4
37,0
34,1
32,3
37,8
48,0
50,6
49,7
53,1
53,0
51,5
51,4
48,8
48,9
48,8
dnf
dnf
18,8
15,5
29,9
25,2
31,4
29,5
33,8
30,8
35,4
31,7
34,3
31,6
34,7
34,0
37,1
35,3
40,4
39,4
44,1
41,2
47,0
44,2
49,8
45,7
53,4
47,8
58,3
49,9
61,5
49,4
60,9
47,4
61,8
47,7
63,0
53,8
41
dnc
15,1
25,2
26,9
29,8
31,6
31,7
31,3
35,5
41,6
47,0
48,7
51,2
52,5
52,3
51,5
49,3
49,4
49,1
4174a
41
dnc
17,0
25,6
29,7
29,3
32,9
32,6
31,2
35,5
42,2
44,9
46,3
49,4
51,0
50,5
50,1
47,8
48,0
48,3
4907f
5558a
2954a
5176f
5550a
40
40
39
39
39
dnf
dnf
dnc
dnf
dnf
20,4
16,1
16,1
17,3
15,1
25,5
24,5
24,6
26,7
24,1
28,9
28,9
27,2
28,5
27,5
28,9
29,9
29,5
29,1
28,5
30,7
31,0
30,4
30,4
28,9
31,2
31,3
29,9
29,2
30,2
31,0
32,5
30,4
30,0
31,8
32,7
34,2
32,5
31,3
35,0
36,2
38,5
38,8
35,6
37,7
39,9
40,5
43,2
39,4
39,1
42,3
43,8
44,8
42,5
41,6
45,4
46,2
46,9
45,2
44,5
48,3
48,9
48,6
48,6
45,5
52,1
52,0
48,7
51,1
47,1
54,9
53,0
48,1
51,9
48,0
56,8
55,6
46,3
50,9
49,4
59,4
56,0
44,0
51,4
51,4
60,8
53,7
46,1
50,3
50,6
4176a
39
dnc
15,0
24,9
26,7
29,2
29,6
30,4
29,2
33,4
39,3
43,2
45,8
48,8
50,9
51,0
51,3
49,1
49,4
48,7
3604
2955a
3373
3133
4955f
3278
2671
3279
3276
3367
4823f
5003f
2888
4171a
5767
2613
4304
4304
5715
3031
3034
5168f
5979
3033
4615f
4705f
3036
38
37
37
37
36
36
36
36
36
36
36
36
35
35
35
34
34
34
34
28
27
27
27
26
26
25
24
dnc
dnc
dnc
dnc
dnf
dnc
dnc
dnc
dnc
dnc
dnf
dnf
dnc
dnc
dnf
dnc
dnc
dnc
dnf
dnc
dnc
dnf
dnf
dnc
dnf
dnf
dnc
13,8
13,3
17,3
17,1
11,4
16,3
17,6
17,4
15,4
13,6
15,6
17,2
14,6
13,8
10,4
13,9
13,2
13,2
13,3
14,0
12,7
14,4
14,8
12,3
13,4
12,5
12,2
22,1
23,2
26,4
25,6
19,8
21,2
20,9
23,1
23,5
24,4
24,9
23,7
20,0
22,9
22,5
21,4
18,8
18,8
21,5
20,2
19,7
19,9
19,5
17,9
17,5
20,9
17,4
25,0
25,8
27,9
27,7
23,2
24,0
24,9
23,2
25,1
26,4
27,7
22,2
21,9
25,1
26,9
23,5
24,3
24,3
23,9
21,4
21,2
20,2
21,9
18,9
20,5
20,7
17,4
26,6
28,2
28,7
27,0
27,6
27,7
25,9
25,9
28,8
28,2
27,6
24,3
24,1
27,2
27,4
24,8
25,1
25,1
24,5
20,6
20,5
21,4
22,7
18,8
18,9
20,1
17,2
29,1
29,4
31,0
28,6
29,0
28,7
26,9
27,2
29,9
29,9
28,3
28,5
26,1
28,0
28,6
25,8
26,9
26,9
26,2
21,6
21,1
23,0
22,8
20,5
19,5
20,7
18,9
29,1
29,4
29,5
28,9
28,1
29,2
28,4
28,0
30,3
28,7
27,2
27,8
26,4
26,9
28,8
25,5
26,1
26,1
25,4
20,9
20,3
21,2
23,3
19,4
20,1
18,9
18,3
29,8
28,3
29,2
29,2
27,4
27,9
27,8
28,0
29,8
29,3
27,0
27,7
26,3
25,9
27,7
25,6
25,4
25,4
25,9
20,4
20,1
20,7
23,5
19,4
19,5
19,0
18,1
31,2
30,6
32,2
32,0
31,4
29,1
29,3
29,3
30,9
31,3
28,8
28,4
27,9
27,3
28,8
27,6
27,9
27,9
27,1
21,4
20,8
21,2
23,7
19,8
19,8
19,1
17,9
35,6
34,2
35,0
34,9
34,5
32,1
32,3
32,5
34,0
34,4
31,4
32,8
31,4
32,0
32,6
30,7
30,5
30,5
30,9
23,4
22,5
22,7
24,4
21,4
21,0
21,4
19,8
40,0
37,9
36,4
37,0
36,5
34,6
35,2
35,7
35,8
36,1
35,6
36,7
34,8
34,9
34,7
35,3
34,1
34,1
33,7
26,9
25,0
24,5
26,1
24,4
24,7
23,3
22,5
42,2
39,1
37,0
38,3
40,0
37,2
37,8
38,5
37,6
37,3
37,8
38,4
37,3
38,6
39,8
38,8
37,4
37,4
35,6
28,9
27,1
26,6
27,4
25,8
27,1
25,0
24,0
44,9
41,2
40,3
40,6
41,9
39,8
40,2
40,8
39,4
39,3
40,1
41,9
38,9
41,3
42,4
42,9
40,1
40,1
39,4
31,1
29,1
28,3
30,5
28,2
28,7
26,0
26,2
47,5
42,8
41,9
42,3
44,4
41,3
43,5
42,1
39,8
40,2
43,3
43,9
41,1
45,0
45,2
46,6
43,8
43,8
42,2
32,5
31,2
30,6
33,2
31,1
30,7
28,6
27,1
49,7
44,0
42,6
42,6
45,4
41,9
47,3
42,6
39,9
40,1
45,5
45,7
42,9
47,4
48,2
49,6
46,2
46,2
45,8
35,1
32,6
32,4
35,2
32,7
32,8
29,4
29,6
50,4
44,0
42,5
42,8
46,1
42,8
49,4
43,0
40,1
39,5
49,4
48,6
42,0
47,9
49,4
48,6
45,9
45,9
46,8
38,5
36,1
34,0
37,5
34,9
35,0
31,5
31,0
50,8
44,2
41,6
42,4
47,3
40,8
51,4
41,3
39,2
37,4
49,7
50,6
42,8
46,1
50,4
48,6
47,4
47,4
47,6
41,8
39,4
35,9
40,8
37,7
37,6
33,0
33,4
50,7
45,3
41,0
42,5
48,6
40,9
54,3
41,5
39,0
35,8
46,4
46,0
44,3
46,5
52,1
48,0
49,6
49,6
54,5
45,3
42,7
36,3
44,0
40,6
37,1
34,0
35,7
50,6
43,9
40,7
41,5
46,2
42,7
56,4
42,4
40,4
36,7
54,5
46,7
44,1
46,9
49,9
46,0
51,8
51,8
54,6
49,3
46,6
40,4
47,9
44,3
40,8
38,0
38,0
Product Name
Cert #
weighted
value
PlAIN with B15
PlAIN (no infill)
Microperforation with B15
Standard perforation with B15*
Extra Microperforation with B15
Extra Microperforation with fleece
Microperforation with fleece
Standard perforation with fleece*
2439
2438
2443
2443
2427
2432
2437
2437
47
44
41
41
40
30
20
20
UlTIMA Tiles + 100mm x 20kg/m
glass fibre overlay to both rooms
UlTIMA dB Concealed Planks
PERlA dB
UlTIMA Tiles + 25mm x 20kg/m3
glass fibre overlay to both rooms
UlTIMA Tiles + 100mm x 20kg/m3
glass fibre overlay to one room
UlTIMA Concealed Planks
UlTIMA dB
CERAMAGUARd
SAHARA Concealed Planks
SAHARA dB
UlTIMA Tiles + 25mm x 20kg/m3
glass fibre overlay to one room
CIRRUS MAx / CIRRUS 75
BIOGUARd PlAIN
NEWTONE Residence
PlAIN
BIOGUARd ACOUSTIC
dESIGN CIRRUS
CIRRUS
CONTRAST Circles, Square
GRAPHIS (all face patterns)
ClEAN ROOM Fl
UlTIMA (Tiles & Mlook Planks)
PERlA
COlORTONE dUNE
SAHARA MAx / SABBIA
SAHARA VECTOR
FINE FISSUREd (incl. Black)
SAHARA (Tiles & Planks)
SAHARA (unperforated)
UlTIMA VECTOR
NEEVA Tegular/Microlook 20
NEEVA Tegular/Microlook 18
PERlA OP Concealed Planks
SIERRA OP Concealed Planks
NEEVA Board 20
UlTIMA OP
PERlA OP (Tiles & Board Planks)
NEEVA Board 18
3
One-Third Octave Band Centre Frequency Hz
Metal range
dnc
dnc
dnc
dnc
dnc
dnc
dnc
dnc
100
125
160
200
250
315
400
500
630
800
1000 1250 1600 2000 2500 3150 4000 5000
25,2
22,1
20,7
20,7
23,0
22,4
17,1
17,1
29,3
27,6
24,1
24,1
25,8
22,3
17,3
17,3
34,6
32,2
29,9
29,9
30,6
24,5
19,0
19,0
34,5
32,7
29,1
29,1
29,6
26,6
21,2
21,2
36,5
34,3
30,9
30,9
32,7
26,8
21,5
21,5
38,6
35,9
32,3
32,3
32,3
27,4
20,2
20,2
39,9
37,5
32,8
32,8
33,2
26,6
18,3
18,3
41,7
38,8
36,8
36,8
34,8
27,3
18,7
18,7
46,7
41,9
39,2
39,2
36,8
27,4
19,5
19,5
50,2
45,0
43,1
43,1
39,4
27,8
19,2
19,2
53,4
46,6
46,5
46,5
40,5
27,3
18,6
18,6
* Estimated
1) All tests have been conducted in an independent third party quality assured
laboratory in accordance with either EN 20140-9/ISO 140-9 or EN/ISO 10848-2
and with the ceiling suspended beneath a continuous cavity.
2) dncw and dnfw values are determined in accordance with EN ISO 717-1.
3) Values for Standard Perf (16% open area) are estimated as being not less than
Micro Perf (22% open area).
55,3
49,1
49,1
49,1
42,0
28,8
18,8
18,8
56,0
51,5
51,8
51,8
44,7
30,2
19,8
19,8
59,4
55,3
55,5
55,5
47,9
32,2
20,8
20,8
59,2
57,7
57,7
57,7
51,1
33,3
21,0
21,0
55,5
55,4
55,2
55,2
52,7
33,6
21,1
21,1
59,2
58,9
58,8
58,8
55,2
33,9
20,4
20,4
63,4
63,0
62,0
62,0
57,1
34,2
20,1
20,1
4) Armstrong conducts extensive and regular acoustic tests on its ceiling tiles and
planks. Inevitably slight variations occur over a range of results for the same
product.
The results above do not necessarily represent the highest achieved but indicate
values that can be consistently and confidently offered.
19
HEAlTH ANd ClEANlINESS
DID You Know...
it’s all aBout air
Quality Control:
■
■
■
■
■
■
The air penetrating the
Clean Room can be filtered
depending on the size of
the undesired elements.
Air can be recycled up to
60 times per hour for the total
volume of the space.
New air is also introduced
to avoid a build up in the
concentration of CO2 and
maintain enough oxygen
for the people working there.
Operators in a clean room
have to wear equipment such
as a clean room suit, hair
cover, gloves, shoe-protection,
or mask.
There are 2 types of rooms:
• rooms with over-pressure,
to avoid pollutants from
entering (dust, bacteria,…)
• rooms with negative
pressure, to avoid various
contaminants from escaping to
the outside (viruses, bacteria,
spores,…).
Building materials used in
such spaces shall not have
a negative impact on the
pursuance of cleanliness and
should preferably contribute
actively to a better
environment.
Clean room
A clean room is a space or a series of spaces where the concentration
of particles is controlled in order to minimise the introduction, generation,
retention of particles inside, generally for a specific industrial or research
objective, as well as in healthcare environments. Parameters such as
temperature, humidity and relative pressure are also maintained at a precise
level, as defined in ISO 14644-1.
• Clean rooms are classified ISO 1 (cleanest) to ISO 9 depending on the
number of particles measured.
• The performance is tested to ISO 14644-1 which determines the particle
cleanliness class. Although US Federal Standard 209E has been officially
withdrawn, it is continuously used as a reference.
The following table shows the equivalence between the 2 standards.
(particles in each cubic metre equal to or greater than the specified size)
> 0.1μm
Particle size
> 0.2μm > 0.3μm > 0.5μm
ISO Class 1
10
2
ISO Class 2
100
24
ISO Class 3
1 000
237
102
35
8
Class 1
ISO Class 4
10 000
2 370
1 020
352
83
Class 10
ISO Class 5
100 000
23 700
10 200
3 520
832
ISO Class 6
1 000 000 237 000 102 000
35 200
8 320
> 1μm
4
Class 100
293
ISO Class 7
352 000
83 200
2 930
Class 10 000
3 520 000
832 000
29 300
Class 100 000
ISO Class 9
35 200 000 8 320 000
293 000
Class 1 000 000
BIOGUARd paint has enhanced resistance
to disinfectants.
healthCare premise
In Healthcare premises, it is of critical importance to avoid Hospital acquired
infections.
According to the level of risk, the necessary clean room performance will vary,
generally between ISO 5 and ISO 8.
All products below:
• can be used in ISO 5 environments and are certified against ISO 14644-1;
• inhibit growth of bacteria, moulds and yeasts (tested against norms
NF S 90-351 (France) and jIS Z2801);
• can be washed with diluted disinfectants.
Constraints
System solution
Level of performance
Operating Theatre
Fully air-tight
Flush surface finish
Anti-microbial
ORCAl BIOGUARd Plain ClIP-IN with
appropriate silicone or mastic joint
ISo 3
High pressure
water cleanable
Non-magnetic
ClEAN ROOM grid with plastic hold-down clips & ClEAN ROOM Fl
ISo 5
Anti-static
Anti-microbial
ClEAN ROOM grid with plastic hold-down clips & BIOGUARd
ACOUSTIC
ISo 4
Bioguard treatment
ClEAN ROOM grid with plastic hold-down clips & BIOGUARd
ACOUSTIC or ORCAl BIOGUARd ExTRA MICROPERFORATEd
Board with fleece and PREMIUM B15
ISo 4
washable
0.65 aw sound absorption
Intensive Care
Anti-microbial
Wake-up Room/Maternity Good air-tightness
laboratory/ Pharmacy
Good acoustical environment
grid and tiles for Clean room enVironments
GRID
MInERAL
MEtAL
CLEAn RooM
Grid
BIoGuARD
PLAIn
BIoGuARD
ACouStIC
CLEAn RooM fL
oRCAL BIoGuARD
Extra
Microperforated
with fleece and
Premium B15
oRCAL BIoGuARD
Plain
Zone 1, 2 & 3
Zone 1, 2 & 3
Zone 1, 2 & 3
Zone 1, 2 & 3
Zone 1, 2 & 3
Zone 1, 2, 3 & 4
ISO 4
ISO 5
ISO 5
ISO 5
ISO 5
ISO 3
Material
Aluminium
Mineral
Mineral
Mineral
Steel with acoustic
fleece and mineral
infill
Steel
Surface
PVC
Bioguard
Paint Glass veil with
Bioguard paint
Polyester film
Extra
Microperforated with
Bioguard polyester
powder paint
Unperforated
with Bioguard
polyester powder
paint
Classification NF S 90-351
type of space
latest information available on our website
BIOGUARd products achieve ISO 5 to ISO 3
in accordance with ISO 14644-1.
Class 1 000
Some examples of spaces and system solutions:
20
The BIOGUARd paint treatment has additional active components
which reduce the colony size of virulent strains of bacteria, moulds
and yeasts.
-
ISO Class 8
MRI
System solutions for the
Pharmaceutical, Food and
Manufacturing Industry can
be found in our brochure
“Solutions for Clean Room
Environments”.
> 5μm
-
10
DID You Know...
BIOGUARd products have been especially designed for the
Healthcare sector.
uS federal
Standard 209E
Maximum number of Particles in Air
ISo Class
the Bioguard solution
Particle cleanliness class
Resistance
to disinfectants
Quaternary Ammonium, Hydrogen Peroxide, Chlorine
*
Quaternary Ammonium,
Hydrogen Peroxide, Chlorine
* Not tested
21
FIRE
reaCtion to fire
The harmonisation of technical standards
within Europe, and the integration
of EN13964 (Suspended ceilings –
requirements and test methods) into
national legislation, means that there is
now one series of harmonised European
test methods and classifications for the
reaction to fire of suspended ceilings.
These new reaction to fire classifications,
or ‘Euroclasses’, are made in
accordance with EN13501-1:2007.
The ‘Euroclasses’ replace the old
national fire reaction ratings for showing
the performance of ceilings in order
to meet the Construction Products
directive and national building regulation
requirements for internal linings.
As reaction to fire is one of the essential
safety requirements identified for
suspended ceilings, the Euroclass
classification is one of the mandatory
elements on the CE mark for suspended
ceiling tiles and grids.
The ‘Euroclasses’ rate from A1 through
to F, as shown in the table opposite,
with A1 being the best reaction to fire
performance and F the worst.
Each member state then sets the
performance level required for different
areas and building types within their
own building regulations.
depending upon the reaction to fire
test(s) conducted, the rating may include
an additional classifications for smoke
production and flaming droplets.
Smoke and flaming droplets are
regulated in some European countries.
Smoke production is rated from s1
(the least smoke produced) to s3
(no limit to amount of smoke produced).
Flaming droplets is rated from d0
(no flaming droplets) to d2 (no limit
to flaming droplets).
Assessed Performance under Structural Steel Beams - Base test Report: 134086 (70995 for Clip-In)
ULTIMa
ULTIMa dB
ULTIMa OP
PerLa
PerLa OP
SIerra
BIOgUard aCOUSTIC / BIOgUard PLaIn
FIne FISSUred
PLaIn
CIrrUS
MeTaL Plain + pad or B15
MeTaL Std Perf + pad or B15
MeTaL Microperf + pad or B15
MeTaL extra Microperf + pad or B15
MeTaL Plain + pad
MeTaL Std Perf + pad
MeTaL Microperf + pad
MeTaL extra Microperf + pad
Board
Tegular
MicroLook
Flush Tegular
Clip-In 3mm
Comments
90 minutes
60 minutes
30 minutes
60 minutes
30 minutes
60 minutes
60 minutes
60 minutes
60 minutes
60 minutes
60 minutes
60 minutes
60 minutes
60 minutes
n/a
n/a
n/a
n/a
60 minutes
60 minutes
n/a
60 minutes
n/a
60 minutes
60 minutes
60 minutes
60 minutes
60 minutes
60 minutes
60 minutes
60 minutes
60 minutes
n/a
n/a
n/a
n/a
60 minutes
60 minutes
n/a
60 minutes
n/a
60 minutes
60 minutes
30 minutes
30 minutes
30 minutes
60 minutes
60 minutes
60 minutes
60 minutes
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
60 minutes
60 minutes
60 minutes
60 minutes
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
30 minutes
30 minutes
30 minutes
30 minutes
Includes 500 x 500 and 1200 x 300 MicroLook ULtIMa
Includes Colortone Black
Does NOt include GraphIs
Does NOt include any CIrrUs Design tiles
8mm and 16mm returns. 18mm 100kg/m3 aFBtF pad
8mm and 16mm returns. 18mm 100kg/m3 aFBtF pad
8mm and 16mm returns. 18mm 100kg/m3 aFBtF pad
8mm and 16mm returns. 18mm 100kg/m3 aFBtF pad
600 x 600 only. 40mm 45kg/m3 aFBtF pad
600 x 600 only. 40mm 45kg/m3 aFBtF pad
600 x 600 only. 40mm 45kg/m3 aFBtF pad
600 x 600 only. 40mm 45kg/m3 aFBtF pad
struCtural fire proteCtion
Throughout Europe, there is a
requirement for a building’s structure
to be protected from fire. This is primarily
for the structure to remain stable during
a fire to allow the occupants to escape
and also to enable fire fighters to work
without threat of the building’s collapse.
The duration of the required protection
will usually depend upon the height of,
and location within, the building (i.e.
typical floor, basement, roof construction
etc), whether there is any active methods
of fire protection (sprinklers etc) and the
type of construction to be protected
(steel beams, timber or mezzanine floors
etc).
A fire protecting suspended ceiling
system is one of several important
methods of providing the fire protection
which fire degradable elements of the
structure require. Ceilings can be used
to enable a floor construction to meet
the duration of protection required by
the building regulations that it could
not necessarily provide on its own.
There are many national test methods for
establishing the structural fire protection
performance of a suspended ceiling
system, as well as several European
norms which are acceptable in most
European countries. The performance
achieved during testing will be classified
in terms of the duration of protection
given, typically this in accordance with
EN13501-2:2007 for European tests.
However, there is not yet one single
European test method which
is acceptable to all member states.
Untested products may be assessed by
reference to the product attributes and
comparison to similar tested products,
provided this is supported by an
assessment report from a recognised fire
expert and should be provided with the
22
latest information available on our website
base test report that details how
the product should be installed to
achieve the assessed performance.
The location and type of various service
elements such as lighting fittings,
smoke detectors etc, are infinite and
the designer and installer must satisfy
themselves that they can be integrated
without reducing the tested performance
of the ceiling system. This will usually
require a test report from the fitting
manufacturer or an assessment issued
by the fire authorities. Without these
documents the designer or installer
may assume an everlasting responsibility
for the fire safety of the building and
occupants.
The complete construction and assembly
of the test installation is important to the
success of the test, and Armstrong test
many ceiling tiles for their structural fire
performance, but always on Armstrong
Trulok grid.
There are many other details of the test
construction that must be understood
and adhered to. These include:
• main runner and hanger centres
• the type of top fixings and how the
hangers are attached to them
• the minimum depth of the ceiling void
• what % of the floor design load is
tested
• whether ceiling tile hold-down clips
were used.
These details must be included in the
installation if the tested performance
is to be realised and they should
be taken into account when writing
specifications for ceilings intended
to provide structural fire protection.
This document is based on a large
number of fire tests conducted on
various Armstrong ceiling tile and grid
types. It provides an assessment of
the performances attainable when
various Armstrong tile and grid systems
are installed in accordance with the
appropriate base fire test and the
permitted installation variations from
that base test.
The tables opposite give a summary
of the performances achievable as stated
in the assessment document and are
correct at the time of going to print.
As products may be modified
or retested it is essential that their
validity is always checked prior
to installation. therefore, the current
version of the assessment document
173816 and the relevant base test
report should always be consulted
prior to the installation of a floor
construction to be protected by
an Armstrong ceiling system.
A full document is always required
and must be read and any limitations
understood. Abridged versions must
be regarded as undesirable as they
will not show the full test details and
construction.
Assessed Performance under timber floors - Base test Report: 167751
ULTIMa
ULTIMa dB
FIne FISSUred
ULTIMa / ULTIMa dB
PerLa
SIerra
BIOgUard aCOUSTIC / BIOgUard PLaIn
FIne FISSUred
PLaIn
CIrrUS
Board
Tegular
MicroLook
Flush Tegular
Clip-In 3mm
60 minutes
60 minutes
n/a
30 minutes
30 minutes
30 minutes
30 minutes
30 minutes
30 minutes
30 minutes
60 minutes
60 minutes
n/a
30 minutes
30 minutes
30 minutes
30 minutes
30 minutes
30 minutes
30 minutes
60 minutes
60 minutes
n/a
30 minutes
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Comments
Main runners at 600mm centres only
Includes Colortone Black
Does NOt include GraphIs
Does NOt include any CIrrUs Design tiles
Assessed Performance under Mezzanine floors - Base test Report: 120559
ULTIMa / ULTIMa dB
ULTIMa dB
PerLa
SIerra
BIOgUard aCOUSTIC / BIOgUard PLaIn
FIne FISSUred
PLaIn
CIrrUS
Board
Tegular
MicroLook
Flush Tegular
Clip-In 3mm
Comments
60 minutes
60 minutes
30 minutes
30 minutes
30 minutes
30 minutes
30 minutes
30 minutes
60 minutes
60 minutes
30 minutes
30 minutes
30 minutes
30 minutes
30 minutes
30 minutes
30 minutes
30 minutes
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Includes Colortone Black
Does NOt include GraphIs
Does NOt include any CIrrUs Design tiles
All Armstrong test reports, certificates
and assessments are freely available
on request from our Internal technical
Sales team.
The fire performance of floor structures
protected by Armstrong ceiling tile
and grid systems is given in the fire
assessment document 173816.
23
TECHNICAl GlOSSARy
Fire reaction
National Building Regulations (where applicable) require that
buildings meet the appropriate Euroclass fire reaction performance
depending upon the area of application. Armstrong products have
been tested to the harmonised European fire reaction standards and
meet the minimum performance criteria. Many Armstrong products
have also been tested for their fire resistance performance under
various floor constructions. See page 22 for more information on
how ceilings can create a safer environment
Light Reflectance
High levels of light reflectance from suspended ceilings can contribute
significantly to maintaining the correct levels of illumination for all
interior environments, as well as helping to reduce excessive electrical
energy consumption. Armstrong conducts extensive tests of light
reflectance on a wide range of its products, in accordance with
EN ISO 7742-2 and 3 (as specified in EN 13964) and ASTM E1477,
by third party accredited laboratories. The light reflectance values
indicated on each product data page are as determined by these
tests.
Acoustic Performance
The occupant of a space, be it an office, a classroom, a shop,
or any similar environmental needs:
• Intelligibility – to hear and to be understood
• Confidentiality – to not be overheard
• Concentration – to not be disturbed
The optimum acoustic climate will be obtained with the right
combination of sound absorption and sound attenuation, and can be
supplemented by the use of active acoustics. See page 17 for more
information on how acoustics can create a better environment.
Anti-Microbial Performance
The control of bio-contamination is essential in the healthcare sector,
especially in hospitals and clinics. Armstrong ceilings do not favour
the development of fungi/mould or yeast and the products can be
used in any general area. The Armstrong Bioguard paint reduces
the colony size of virulent strains of bacteria, moulds and yeasts.
This special paint finish can be cleaned and disinfected. See page
20 for more information on how ceilings can create a healthier
environment.
Sound Attenuation
Is the control of horizontal sound transmission through a suspended
ceiling and common void located above adjacent spaces.
Air Quality
Armstrong offer a number of specific tile and grid solutions to limit
the number of airborne particles in a clean room environment. These
products are tested against ISO 14644-1. See page 20 for more
information on how ceilings can create a cleaner environment.
Sound Absorption
Is the control of reflected sound, provided by the suspended ceiling,
within a space.
Class A
Thermal Conductivity
The ever increasing commitment to energy conservation, dictates
that buildings should be as energy efficient as is compatible with their
function, use and as specified in national building regulations. Interior
building products which can form part of the external structure, such
as suspended ceilings beneath a roof construction, can contribute to
minimising the loss of heat to the exterior by reference to their thermal
conductivity values. Armstrong conducts extensive tests of thermal
conductivity on a wide range of its products, in accordance with
EN 12667 (as specified in EN 13964) and ISO 8301, by third party
accredited laboratories. The thermal conductivity values indicated
on each product data page are as determined by these tests.
European Sound Absorption Class
A single-number rating for random incidence sound absorption
coefficients as calculated by reference to EN ISO 11654.
Sound Reduction
Is the control of vertical sound transmission through a suspended
ceiling located above a space.
Rain Noise
Is the intensity of sound (LIA) generated by rainfall on building
elements, such as lightweight roof constructions, which radiates into
the room below.
Scratch Resistance
Superior level of surface scratch resistance, evaluated with the Hess
rake test.
Humidity Resistance
Ceiling installations are facing more and more demanding humidity
conditions such as fast track programmes, buildings with intermittent
heating and cooling, areas with a high concentration of people,
structures which are open to the exterior environment, etc. To meet
these requirements Armstrong offer a wide range of standard
products suitable for installation in conditions of up to 95% and 99%
relative humidity, as well as specialist products which excel in extreme
conditions of up to 100% relative humidity.
The following table demonstrates the relative humidity resistance
in relation to classes of exposure according to EN 13964.
24
Class
Conditions
A
Building components exposed to varying relative humidity up to 70%
and varying temperature up to 25°C but without corrosive pollutants
B
Building components exposed to varying relative humidity up to 90%
and varying temperature up to 30°C but without corrosive pollutants
C
Building components exposed to varying relative humidity up to 95%
and varying temperature up to 30°C and accompanied by a risk of
condensation but without corrosive pollutants
D
More severe than the above
latest information available on our website
Product Handling & Durability
Frequent ceiling tile removal, typically in areas where building service
equipment is located, means that a higher level of impact resistance
can be desired. In this category, the level of durability and impact
resistance has been improved by Armstrong.
%
Recycled Content
Armstrong products are produced using a variety of recycled
raw materials. The recycled content of individual products is indicated
in our literature in accordance with ISO 14021:2004. See page 7
for more information on how ceilings can create a more sustainable
environment.
15 YEAR
15 year Guarantee
Armstrong World Industries guarantees the Armstrong 95% and 99%
relative humidity products shall be free from defects in materials or
workmanship for 15 years from the date of installation of the material
subject to the terms detailed opposite.
lifEtimE
LifeTime Guarantee
The result of continuous product line development and improvement
allows us to offer a new Lifetime guarantee for our SAHARA,
SAHARA dB and SAHARA MAX / SABBIA product ranges.
guarantee
guarantee
Cleaning and disinfection
The frequency and cleaning method of a ceiling varies from
one application to another. All products can at least be cleaned with
a dry cloth or vacuum cleaner.
Ce marKing
what is it ?
CE stands for Conformité Européenne, which
translated literally, means “European Conformity”.
The CE mark is a products “passport” for
entry into the EEA (European Economic Area)
and indicates that the product complies with
the requirements of the applicable European
directive.
■
Wipeable with a dry cloth.
Wipeable with a moist cloth.
Washable with a sponge dampened in water containing
mild soap or diluted detergent.
Scrubbable with water containing mild soap or diluted
detergent.
Can be cleaned using a high pressure water spray.
Can be cleaned with disinfectants commonly used in
Healthcare premises.
Air Leakage
The cavity above a suspended ceiling may be used as part of
the mechanical air distribution system, when it is used as a supply or
extract plenum, and the air pressure in the plenum will be either positive
or negative in comparison to the pressure in the room below. Similarly
for ‘Clean Room’ applications, where it is most important to prevent
the ingress of airborne dust contaminants, the room will be at positive
pressure to the surrounding areas. Alternatively, to escape the egress
of pathogens the room may be kept at a lower pressure relative to the
surrounding areas. In these situations, it is necessary to know how much
air leakage occurs through the ceiling system as a result of the pressure
differential. Armstrong conducts extensive tests of air leakage on a wide
range of its products, in accordance with EN 12114 and EN ISO 13829,
by third party accredited laboratories. Please contact your local
ATS/MSC centre for further details of these results.
Air flow
When using Metal perforated metal suspended ceilings, the cavity above
may be used as part of the mechanical air distribution system when it
is used as a supply plenum. With this arrangement the air pressure in
the plenum is always positive in comparison to the pressure in the room
below. Specific tiles can be selected as open (active), and these will
become air diffusers, while the remaining tiles will have their perforations
blocked (inactive). In this way the air flow supply volume to the room can
be controlled and balanced dependent upon the pressure differential and
the air change requirements.
Armstrong conducts extensive tests of air flow on a range of its more
common Orcal products, in accordance with EN 12114 and EN ISO
13829, by third party accredited laboratories. Please contact your local
ATS/MSC centre for further details of these results.
For construction products the European directive
is the Construction Products directive
(89/106/EEC).
The CPd identifies the essential requirements
for products (and total projects) such that they are
fit for intended use as:
• mechanical resistance and stability;
• safety in case of fire;
• hygiene, health and environment;
• safety in use;
• protection against noise;
• energy economy and heat retention.
For suspended ceilings, the way in which we
must test and communicate performance for
these essential requirements has been defined in
a new standard published in the “Official journal”
EN 13964 Suspended Ceilings –
Requirements and Test Methods.
what does this mean?
This standard identifies how the ceiling
components must be tested against the
essential requirements to identify a performance
classification. It also indicates how the
manufacturer must ensure that their products
maintain these levels of performance on an
ongoing basis.
■
On 1st july 2007, it became mandatory for
all suspended ceilings and accompanying
suspension systems (in the scope of EN 13964)
to carry the CE mark and the accompanying
essential requirement test information.
From 1st july 2007, onwards, non-CE marked
materials are no longer saleable into the EEA.
25
PROdUCT SElECTOR
Semi-concealed
& concealed
Visible grid
By SUSPENSION SySTEM
Visible grid
Semiconcealed
Visible grid
Semi-concealed & concealed
Concealed
40mm
Prelude xl2/Tl
15 mm
Silhouette xl2
15 mm
Interlude xl2
15 mm
Prelude xl /Tlx
24 mm
Prelude Sixty2
2
Prelude xl /Tlx
24 mm
Prelude Sixty2
2
Prelude xl /Tlx
24 mm
Prelude Sixty2
2
Prelude xl /Tlx
24 mm
Prelude Sixty2
2
Board & tiles
Microlook/
Microlook BE
Prelude 24 mm
Main Runner
Prelude Sixty2
Prelude xl2/Tl
15 mm
Silhouette xl2
15 mm
Interlude xl2
15 mm
System Z
Planks
Prelude xl2/Tlx 24 mm Prelude xl2/Tlx 24 mm Prelude xl2/Tlx 24 mm
Prelude Sixty2
Prelude Sixty2
Prelude Sixty2
C-Channel with
Spring T
Mineral & Metal: Board & tiles
Tegular
Board
Vector
Board
Sl2
Sl2
✔
✔
✔
✔
Mineral Laminated
Microlook
Tegular / Tegular 2
Board
✔
✔
dP12 with
GemaGrid
j-Bar / H-Profile
Metal: tiles & Planks
Vector
T-Clip F
S-Clip, Q-Clip,
R-Clip
HOOK-ON
Mineral Decorative
ULtIMa
✔
✔
✔
ULtIMa Op
✔
✔
✔
ULtIMa dB
✔
✔
✔
OptIMa
✔
✔
✔
perLa
✔
✔
✔
✔
✔
COLOrtONe DUNe
✔
COLOrtONe FINe FIssUreD BLaCk
✔
✔
perLa Op
✔
✔
✔
perLa dB
✔
✔
✔
sIerra Op
✔
✔
✔
✔
Neeva
✔
✔
✔
✔(1)
✔
✔
✔
✔
✔
✔
✔
✔
COLOrtONe Neeva
DesIGN CIrrUs(2)
✔
GraphIs
✔
vIsUaL
✔
✔
(2) Contrast
(1) NEEVA Planks are also available with Microlook & Tegular edge detail. Please see page 35.
Specific Solutions
(3)
Mineral Non Laminated
BIOGUarD aCOUstIC
✔
✔
✔
BIOGUarD pLaIN
✔
✔
✔
paraFON hyGIeN
✔
CeraMaGUarD
✔
sahara
✔
✔
✔
sahara MaX / saBBIa
✔
✔
✔
NewtONe
✔
sahara dB
✔
✔
✔
CLeaN rOOM FL
✔
CIrrUs
✔
✔
✔
CIrrUs MaX / CIrrUs 75
✔
✔
✔
✔
(3) Clean Room Grid or Prelude 24 Corrosive Resistant Grid are recommended for Clean Room environments and Healthcare premises.
✔
pLaIN
✔
✔
✔
FINe FIssUreD
✔
✔
✔
Metal
Wood
26
MaDera veNeers
✔
✔
✔
✔
MaDera LaMINates
✔
✔
✔
✔
latest information available on our website
eXtra MICrOperFOrateD
✔
✔
✔
✔
✔
✔
✔
MICrOperFOrateD
✔
✔
✔
✔
✔
✔
✔
✔
perFOrateD
✔
✔
✔
✔
✔
✔
pLaIN
✔
✔
✔
✔
✔
✔
✔
preMIUM B15
✔
✔
✔
✔
✔
✔
✔
BIOGUarD
✔
✔
✔
✔
✔
✔
✔
27
PROdUCT SElECTOR
By MATERIAl
Mineral Laminated
Mineral Decorative
UlTIMA, UlTIMA OP, UlTIMA dB
OPTIMA
PERlA, PERlA OP, PERlA dB
SIERRA OP
NEEVA
CoLoRtonE nEEVA
CoLoRtonE DunE
Carrara
(CA)
CIRRUS IMAGE
Blue
Mountain
(BT)
CONTRAST CIRClES
Platinum
(PN)
CONTRAST SQUARE
Black
(BK)
Metal
(MT)
Carrara
(CA)
jade
(jA)
Navy
(Ny)
Perl
(PF)
Amber
(AB)
Cement
(CG)
CONTRAST lINEAR
VISUAl V64 & V49
Mineral Non Laminated
SAHARA, SAHARA MAx/SABBIA,
SAHARA dB
CIRRUS, CIRRUS MAx/CIRRUS 75
PlAIN
GRAPHIS NEOCUBIC
FINE FISSUREd
GRAPHIS dIAGONAl
GRAPHIS MIx A & B
GRAPHIS PUNTOS
GRAPHIS CUAdROS
Black
Specific Solutions
BIOGUARd ACOUSTIC
Metal
ClIP-IN
AxAl VECTOR
BOARd
TEGUlAR
TEGUlAR 2
MICROlOOK
BIOGUARd PlAIN
ORCAl BIOGUARd
PARAFON HyGIEN
ClEAN ROOM 2
CERAMAGUARd
NEWTONE
HOOK-ON
100% RH
100% RH
Design / Discontinuous Solutions
Plain
Perforated
Microperforated
Extra Microperforated
OPTIMA CANOPy
(mineral)
UlTIMA CANOPy
(mineral)
ORCAl CANOPy
(metal)
AxIOM CANOPy
INFUSIONS CANOPy
Other perforations available on request.
Wood
MADERA LAMInAtES
Curly Maple (CM)
Grid
MADERA - wooD VEnEERS
lime Tree (lM)
Pear (PH)
Beech (BH)
US Cherry (UC)
DESIGnER GRID
US Maple (UM)
EXPoSED SYStEM
AxIOM Profiles & Transition INTERlUdE 15 mm
SIlHOUETTE 15 mm
PRElUdE 15 mm
PRElUdE 24 mm
PRElUdE SIxTy2 24 mm
PRElUdE 35 mm
5
Ø 0.5
PERfoRAtIonS
A1
A2
A8
5
A10
A12
ConCEALED GRID
SySTEM Z
28
latest information available on our website
SPECIfIC APPLICAtIon
CORROSIVE RESISTANT
GRId 24 mm
ClEAN ROOM GRId
24 mm
29
PROdUCT NAMES
Alphabetically
MInERAL
MEtAL
BIOGUARd PlAIN, BIOGUARd ACOUSTIC __ 92
ClIP-IN ______________________________ 106
CERAMAGUARd _______________________ 98
dESIGN & CUSTOMISEd SOlUTIONS
CIRRUS / CIRRUS MAx / CIRRUS 75 _______ 74
(Corridor Ceilings, Floating Ceilings, linear
ClEAN ROOM Fl _______________________ 96
Grid, Tartan Grid, Vertical Baffles,
COlORTONE __________________________ 80
Cellio Ceilings, Wall Claddings) ___________ 116
CONTRAST CIRRUS ____________________ 84
HOOK-ON ____________________________ 114
dESIGN CIRRUS ________________________ 82
lAy-IN _______________________________ 110
FINE FISSUREd ________________________ 78
GRAPHIS Puntos, Cuadros,
Neocubic, diagonal, Mix A & B ____________ 86
GRID
MAdERA _____________________________ 118
AxIOM Transitions & Profiles _____________ 124
NEEVA ________________________________ 64
BANdRASTER ________________________ 132
NEWTONE ____________________________ 100
ClEAN ROOM GRId ___________________ 134
OPTIMA _______________________________ 54
CORROSIVE RESISTANT GRId __________ 134
PARAFON HyGIEN ______________________ 94
INTERlUdE __________________________ 126
PERlA ________________________________ 56
PRElUdE 15 / 24 ______________________ 128
PERlA dB _____________________________ 60
PRElUdE SIxTy2 / 35 __________________ 130
PERlA OP _____________________________ 58
SIlHOUETTE _________________________ 127
PlAIN _________________________________ 76
SUSPENSION Hangers _________________ 133
SAHARA ______________________________ 66
SySTEM Z ____________________________ 133
SAHARA dB ___________________________ 72
SAHARA MAx / SABBIA __________________ 70
SAHARA Planks ________________________ 68
CAnoPY
SIERRA OP ____________________________ 62
AxIOM CANOPy ________________________ 40
UlTIMA _______________________________ 46
INFUSIONS CANOPy ____________________ 42
UlTIMA dB ____________________________ 52
OPTIMA CANOPy _______________________ 34
UlTIMA OP ____________________________ 50
ORCAl CANOPy _______________________ 38
UlTIMA Planks _________________________ 48
UlTIMA CANOPy _______________________ 36
VISUAl _______________________________ 88
30
latest information available on our website
2 > Product information
Design / Discontinuous Solutions
optima Canopy
ULtima Canopy
34
36
oRCaL Canopy
38
40
iNFUSioNS Canopy
42
46
48
50
52
optima
SiERRa op
62
64
pERLa dB
54
56
58
60
66
68
70
SaHaRa dB
72
pLaiN
CiRRUS maX / CiRRUS 75
74
80
82
CoNtRaSt CiRRUS
84
86
92
92
paRaFoN HYGiEN
aXiom Canopy
Mineral Laminated
ULtima
ULtima planks
ULtima op
ULtima dB
pERLa
pERLa op
NEEVa
Mineral Non Laminated
SaHaRa
SaHaRa planks
SaHaRa maX / SaBBia
CiRRUS
FiNE FiSSURED
76
78
ViSUaL
88
Mineral Decorative
CoLoRtoNE DUNE & NEEVa
DESiGN CiRRUS
GRapHiS
Specific Solutions
BioGUaRD aCoUStiC
BioGUaRD pLaiN
CLEaN Room FL
94
96
CERamaGUaRD
NEwtoNE
98
100
Metal
technical information
CLip-iN Q-CLip, R-CLip
104
106
CLip-iN S-CLip F, t-CLip F
108
LaY-iN
axal Vector, Board, microLook
LaY-iN tegular
Hook-oN
110
112
114
DESiGN & CUStomiSED
SoLUtioNS
116
SYStEm Z
133
134
135
Wood
maDERa
microLook / Vector / SL2
118
aXiom profiles & transitions
124
126
127
128
Grid
iNtERLUDE
SiLHoUEttE
pRELUDE 15
pRELUDE 24
pRELUDE SiXtY²
pRELUDE 35
BaNDRaStER SYStEm
129
130
131
132
SpECiFiC appLiCatioN
SUSpENSioN & SYStEmS
31
ArchitecturAl And environmentAl trends
Design trends are a direct result to changing
social, economical and ecological influences.
Today’s architecture is eco-responsible
and sustainable, combined with a design
spectrum ranging from “minimalist” to fully
exposed.
The consideration of energy efficiency and
environmental impact (CO2 footprint, waste,
recycled content, recyclability) of building
materials is paramount in the design and
construction phases of the building.
Interior finishes equally set the levels of
comfort and work efficiency when the space
is occupied.
Ceilings, representing the largest exposed
interior finish in a building, are a key
contributor towards defining the aesthetics,
acoustics and lighting performance of building
interiors.
Whether considering an exposed structure
that utilises the thermal mass properties
of the concrete slab or creating a wall to
wall ceiling surface, Armstrong offers ceiling
designs, materials and performances to
complement architectural concepts, ranging
from monolithic to discountinous visuals.
ULTIMA Canopy
discontinuous solutions with the cAnopy
DESIGN / Discontinuous Solutions
■ OPTIMA
CANOPY
■ ULTIMA CANOPY
■ ORCAL CANOPY
■ AXIOM
CANOPY
■ INFUSIONS CANOPY
In response to new architectural trends calling for acoustical and
design solutions using exposed soffits and to address the increasing
focus on end users’ well being, Armstrong has designed a range
of discontinuous ceilings to deliver the highest quality of workplace
standards whilst supporting the original architectural concept.
Available to be designed in an exposed structure project
or to complement an existing wall to wall ceiling solution, canopy
elements may be:
■ Visually striking for a contemporary accent;
■ Aesthetically integrated and non obtrusive with an emphasis
on performance;
■ Coloured to create contrast and rhythm;
■ Shaped to coordinate with furniture;
■ Grouped to replicate key architectural features;
■ Curved to create a cocooning effect and an intimate setting;
■ Textured or microperforated to suit design themes;
■ Retrofitted under an existing wall to wall solution providing
a “destructured” visual;
■ Intelligent, loaded with technology and service elements;
■ Environmental friendly, with “no waste” on site;
■ Custom because …you are one of a kind!
InfUsIons Canopy
32
33
OPTIMA CANOPY
Discontinuous Solutions > Mineral > OPTIMA CANOPY
82%
87%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content
PHYSICAL DATA
Light Reflectance
Intelligibility
Concentration
AvAILAbLE SHAPES
Colour*
Edge
White
Painted scrim on edges
Nominal 1200 x 1200 mm
1170 mm
1170 mm
1020 mm
*other RAL colours available on special request
1170 mm
1170 mm
1170 mm
All OPTIMA Canopies are flat panels.
1040 mm
FLAT
1040 mm
CONCAvE
CONvEx
SqUARE
ITEM NUMbERS
offICE - I online (PT),
oPTIMA Canopy Concave & Convex
Shape
Square
Convex
Concave
Circle
Hexagon
Trapezoid
Left Parallelogram
Right Parallelogram
Small Rectangle
Large Rectangle
Sabines* per item
2.45
2.35
1.85
2.00
1.50
2.05
2.05
2.05
3.85
5.25
* Average of 500-4000Hz, laboratory measurements with units suspended at 1 metre,
in accordance with EN ISO 354:2003. Call your Internal Technical Sales Group for further
information on Canopy acoustic performance.
1170 mm ∅
1170 mm
1170 mm
HExAgON
CIRCLE
1170 mm
1170 mm
1170 mm
1020 mm
LEFT PARALLELOgRAM
- OPTIMA Canopy panel with embedded aluminium frame
- Cardboard top fixing template
- Installation manual
NB: Suspension kit not included. Please order accessory kit based on installation
configuration.
TRAPEzOID
1170 mm
1020 mm
RIgHT PARALLELOgRAM
Nominal 1200 x 2400 mm
2390 mm
1780 mm
KIT CONTENT
1170 mm
1010 mm
Nominal 1200 x 1800 mm
1170 mm
1170 mm
SMALL RECTANgLE
LARgE RECTANgLE
ACOUSTICAL DATA - 1000 mm airspace
7
Equivalent sound absorption area per
canopy (Sabines)
OPTIMA Canopy is a mineral panel,
pre-formed into a convex, concave, square,
rectangle, circle, hexagon, trapezoid,
or parallelogram shape. The different shapes
enable you to accentuate an area and express
your creativity.
OPTIMA Canopies are a creative design
solution suitable for many different room types
and environments with a wide variety
of shapes and designs available.
They improve the overall comfort of a working
environment, offering excellent sound
absorption and light reflectance.
OPTIMA Canopies can be used to provide
a striking design for a new space or be used
to refresh or renovate an existing area.
OPTIMA Canopies provide a bespoke finish
and are very quick and easy to install, either
under plasterboard ceilings, existing grid
systems or to an exposed concrete soffit.
Item nr.
CS 5440
CS 5441
CS 5442
CS 5443
CS 5444
CS 5445
CS 5446
CS 5447
CS 5448
CS 5449
860 mm
6
5
Large rectangle
Rectangle
Square
Circle
4
3
2
1
0
125
250
500
1 000
2 000
4 000
Embedded aluminium frame designed to link to hanging and grouping accessories
Aluminium frame dimensions:
Modules 1200 x 1200 mm: 610 x 610 mm
Modules 1200 x 1800 mm: 610 x 1220 mm
Modules 1200 x 2400 mm: 610 x 1830 mm
Octave Band centre frequency (Hz)
EEA
Euroclass B-s1, d0
90 % RH
15 YEAR
guarantee
EN 13501-1
Nominal 1200 x 1200 mm: 4,50 kg
Nominal 1200 x 1800 mm: 6,80 kg
Nominal 1200 x 2400 mm: 9 kg
Note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes. Detailed acoustical data are presented on pages 17-19 and our web page.
35
ULTIMA CANOPY
Discontinuous Solutions > Mineral > ULTIMA CANOPY
44%
Recycled Content
PHYSICAL DATA
87%
ISO 14021
EN ISO
7742-2 & 3
Light Reflectance
Intelligibility
Concentration
AvAILAbLE SHAPES
1905 x 1180 x 32 mm
White
Painted scrim on edges
Section view (Radius = 3280 mm)
1905 mm: length of the arc
170 mm
Dimensions
Colour
Edge
CONCAvE
CONvEx
62591
62592
62581
62582
32 mm
ITEM NUMbERS
offICE - Bürgermeister (nL),
ULTIMA Canopy Concave & Convex
170 mm
- ULTIMA Canopy panel including embedded anchor points to link
to hanging kits
- 4 x hanging cables (drop length 4.80 metres)
- 4 x gripper structure anchor
- 4 x anchor cap
- 4 x bottom end cable adjuster *
- 4 x gripper bottom end and assembly *
- 4 x Internal barrel cap *
- Top fixing template on carton
- Installation manual
*cable adjustment hardware connecting to panel.
Plan view
Example of Canopy plan view.
1905 mm
1220 mm
ACCESSORIES
Item nr.
CS 5423
Description
Standard hanging kit: 4 cables;
drop length 4.80 metres
Extended hanging kit: 4 cables;
drop length: 9.15 metres
Escutcheon Kit - Used when hanging
ULTIMA Canopy below an existing ceiling.
625530
7006
NB: 2 escutcheon kits required per Canopy.
ACOUSTICAL DATA - 1000 mm airspace
3.5
Equivalent sound absorption area per
canopy (Sabines)
ULTIMA Canopy is a mineral panel,
pre-formed into a convex or concave shape.
The curved shape enables you to accentuate
an area and express your creativity. In addition,
these can be installed with an angle of up to
45° from horizontal.
The ULTIMA Canopy is a creative design
solution for open areas, offering excellent
sound absorption and light reflectance.
ULTIMA Canopies improve the overall
comfort of an individual working
environment.
ULTIMA Canopies provide a bespoke finish
and are very quick and easy to install.
ULTIMA Canopies can be used to renovate an
existing area. In addition, no special tools are
required for installation. You can easily
adjust and fit the canopy to a variety of heights
and angles.
32 mm
610 mm
KIT CONTENT
1180 mm
1 piece per carton
2 pieces per carton
3
2.5
Concave
Convex
2
1.5
1
0.5
0
125
250
500
1 000
2 000
4 000
Octave Band centre frequency (Hz)
EEA
Euroclass A2-s1, d0
70 % RH
15 YEAR
guarantee
 23 kg/pc.
EN 13501-1
Note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes. Detailed acoustical data are presented on pages 17-19 and our web page.
37
Discontinuous Solutions > Metal > ORCAL CANOPY
30%
Recycled Content
PHYSICAL DATA
85%
ISO 14021
EN ISO
7742-2 & 3
Light Reflectance
Concentration
AvAILAbLE SHAPES
1890 x 1181 x 40 mm
White (RAL9010)*
- Curved (concave/convex):
edge detail width: 47°
edge detail length: 90°
- Flat: all sides 47°
- Front side : Extra Microperforation
0.7mm, 1% free area, for a clean visual
- Rear side: Standard perforation 2,5mm,
16% open area, for additional
acoustical performance. Enclosed
acoustical pad 20mm, 25 kg/m3
Surface/finish
Section view
CONCAvE
min 200 mm
max 1900 mm
40 mm
156 mm
Dimensions
Colour
Edge detail
CONvEx
40 mm
min 200 mm
max 1900 mm
*other RAL colours available on special request
CONCAvE
CONvEx
FLAT
CS 600064
CS 600065
CS 600063
ITEM NUMbERS
1 piece per carton
FLAT
min 200 mm
max 1900 mm
40 mm
KIT CONTENT
- ORCAL Canopy panel
- 4 x hanging cables (drop length 2,00 metres)
- 4 x gripper structure anchor
- 4 x anchor cap
- 4 x 50mm washer plates
- Installation manual
Plan view
Example of curved Canopy plan view.
ACCESSORIES
Description
Standard hanging kit: drop length
2 metres
Flat washer
CS 600068
1181 mm
1890 mm
Item nr.
CS 600066
600.5 mm
ORCAL Canopy is part of Armstrong’s
extensive range of discontinuous ceilings and
canopies. The canopies come in three different
designs (flat, concave and convex) and give
the designer or specifier the ability to:
■ Create spaces or areas within larger
spaces or rooms, adding definition and
local acoustic comfort (speech intelligibility)
to an area or working zone.
■ Provide a high level of design flexibility as
the canopies come in three different designs
and can be used independently or as
groups and arrays.
The panels come with a high durability paint
finish as standard, making them easy to clean
and maintain. The canopies have an Extra
Microperforation pattern that provides
a clean visual with good acoustical and light
reflectance performances.
The canopy is fully enclosed ensuring that if
the reverse face is visible it fully compliments
the design.
Intelligibility
156 mm
ORCAL CANOPY
ACOUSTICAL DATA - 1000 mm airspace
TRAnsPoRT - nice Airport (fR),
oRCAL Canopy Concave
Equivalent sound absorption area per
canopy (Sabines)
3.5
3
950 mm
2.5
ORCaL flat,
concave
& convex
2
1.5
1
0.5
0
125
250
500
1 000
2 000
4 000
Octave Band centre frequency (Hz)
EEA
Euroclass B-s2, d0
90 % RH
15 YEAR
guarantee
EN 13501-1
Flat: 26.3 kg
Curved (concave/convex) :
28.3 kg
Note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes. Detailed acoustical data are presented on pages 17-19 and our web page.
39
AXIOM CANOPY
Discontinuous Solutions > AXIOM C & AXIOM KE CANOPY
25%
up to
7742-2 & 3
Recycled Content*
PHYSICAL DATA
90%
EN ISO
ISO 14021
Light Reflectance
Intelligibility
AvAILAbLE SHAPES - STANDARD KITS
Colour
Material
Global White / RAL 9010*
Extruded Aluminium
*other RAL colours available on request
3.0 m
2.4 m
1.8 m
1.2 m
1.2 m
10 tiles
8 tiles
6 tiles
4 tiles
1.8 m
15 tiles
12 tiles
9 tiles
2.4 m
20 tiles
16 tiles
3.0 m
25 tiles
Note: Colour available on request. Please contact Internal
Technical Sales.
Item nr.
551411
Description
AXIOM C Tegular Vector profile
A 345
AXIOM C Tegular Vector
corner post
CS 574206
AXIOM KE profile
CS 57
AXIOM KE Canopy
Mitre corner piece
ACOUSTICAL DATA - 1000 mm airspace
A361
A 338G
AXIOM KE Canopy
Mitre corner splice connector
AXIOM universal
splice plate
C 3000
AWDN 21
Primary C channel
Tee bar hanger
A 348
Channel bracket
CA 97
Clamp for C channel
A 347
A 346
24mm XL2 connector clip
15mm XL2 connector clip
A 339
Universal T bar connector clip
7
Equivalent sound absorption area per
canopy (Sabines)
AXIOM C Canopy and AXIOM KE Canopy can
enhance acoustics without sacrificing design.
Now both form and function thrive with
Armstrong’s AXIOM Canopies!
■ AXIOM Canopy is a perimeter trim system
designed to create “ceiling clouds” from full
size tiles. Made from standard ceiling panels
and ready to assemble AXIOM components,
AXIOM Canopies will define and
individualise reception areas, work stations
and meeting areas within open spaces.
■ Create floating ceilings whilst improving
acoustics, reducing noise levels in spaces,
and increasing speech intelligibility over
a specific area.
■ Ideal for acoustically challenged or open
plenum spaces.
AxIOM KE CANOPY SPECIFIC
AXIOM C CANOPY SPECIFIC
AxIOM C AND AxIOM KE CANOPY KIT COMPONENTS
6
5
PERLa OP
4
OPTIMa
15 mm
3,60 m2
3
Metal
Microperforated
Rd1522
2
1
0
125
250
500
1 000
2 000
4 000
Octave Band centre frequency (Hz)
LEIsURE - Theatre (UsA), AxIoM KE
AxIoM C
NB: the AXIOM kit will be available either with 15mm or 24mm grid.
Tiles are not included.
*Note that recycled content is only for the frame. See product page for infill tile for that
recycled content.
Note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes. Detailed acoustical data are presented on pages 17-19 and our web page.
41
INFUSIONS CANOPY
Discontinuous Solutions > Polycarbonate > INFUSIONS CANOPY
COLOUR SwATCH
CONCAvE
CONvEx
PHYSICAL DATA
Dimensions
Square Edge 1525 x 610 x 6 mm
1830 x 610 x 6 mm
Channelled Polycarbonate
Smooth
All colours
Material
Surface Finish
Colour
KIT CONTENT
- Flat INFUSIONS panel with 610mm aluminum extrusions attached
(2 extrusions/panel)
- 2 tension cables to form an arc of 60°
- 2 tension cables to form an arc of 90°
Channelled Intellect
Channelled Sunset
Channelled Vision
Channelled Mist
Channelled Caribbean
Channelled Midnight
NB: Suspension kit not included. Please order accessory kit based
on installation configuration.
ACCESSORIES KIT
Item nr.
7004 A
7005 A
7006
7007
7008
7009
Description
Standard Hanging Kit (2.40 metre)
Extended Hanging Kit (4.80 metre)
Escutcheon Hanging Kit
Linking Kit
Wall Attachment Kit
Wall End Attachment Kit
292mm
1400mm
90° arc
350mm
Accentuate an area, direct the eye,
or provide a touch of intimacy, INFUSIONS
lets you express your creativity in a whole
new dimension. Anchored to the ceiling
or wall with a uniquely simple cable system,
INFUSIONS hover in seeming defiance of
gravity.
In addition to an array of materials, sizes,
colours and textures - the placement,
configuration and lighting options available
make INFUSIONS an invaluable tool for
architects and interior designers.
INFUSIONS provide an ingenious way
to define zones of various sizes for a variety
of purposes - from offering a relaxing respite
to affording a comfortable refuge or setting
an idyllic mood.
Canopies are quick and easy to install, under
either drywall ceilings, existing grid systems
or to concrete.
1675mm
For the INFUSIONS Canopy item numbers, please contact our
Internal Technical Sales group.
203mm
90° arc
RETAIL - Tyco Restaurant (B),
InfUsIons Channelled Midnight
1475mm
240mm
60° arc
1775mm
60° arc
EEA
Euroclass B-s1, d2
15 YEAR
guarantee
1525 x 610 mm: 2.7 kg
1830 x 610 mm: 3.1 kg
EN 13501-1
Note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes.
43
laMinated
the Armstrong range of laminated products provide clean, bright, non
perforated visuals which have been designed for today’s challenging
interior requirements.
these durable surfaces, such as ULTIMA, provide very high levels
of scratch resistance along with up to 90% light reflectance.
Our laminated range also provides superior acoustical control.
depending on end-user requiring intelligibility, confidentiality,
concentration or a balance of these the end user has requirements for,
Armstrong has a solution.
The OP range provides up to 1.00 aw of sound absorption, helping
to control the acoustical environment in open plan spaces.
■
The dB range is designed to offer up to 44 dB of sound attenuation,
helping to provide improved confidentiality within closed office areas.
■
The standard range provides both good sound absorption and
good levels of sound attenuation to provide the perfect blend of
acoustical comfort in general room spaces.
■
PERLA OP
MINERAL
■ LAMINAtEd
■ NON
LAMINAtEd
■ dEcORAtIvE
Monolithic SolutionS...
SAHARA
Suspended ceiling systems have moved from providing mainly
functional features (masking the building’s infrastructure whilst
providing accessibility) to contributing on a much greater scale
to the interior design, acoustics and overall environmental impacts
with such innovations as tech Zone. daylight optimisation with
high ceiling tile light reflectance values has led to the increasing
consideration of whiter and larger modules with finer textures.
Aiming at minimising aesthetical intrusions in the ceiling plan,
Armstrong has further developed vector, an edge detail producing
a concealed grid and more monolithic look. In spaces where eye
catching visuals are the main drive, Armstrong’s research in designer
grids has also exciting new avenues to generate rhythm in the ceiling
plane with the Interlude range.
non laMinated
decorative
this classic range of products provides a blend of performance, quality
and affordability for which the Armstrong ceiling brand is famous.
the range of dUNE finishes highlights the core line of ceilings from
Armstrong. these finely textured visuals, either plain or perforated,
provide good levels of sound absorption and sound attenuation.
Our latest ‘MAx’ versions of both SAHARA and CIRRUS offer
increased levels of absorption whilst the SAHARA dB range
provides high levels of sound attenuation.
the Armstrong decorative range recognises that there are many areas
within a building where a designer or end user would like to express
a theme, or use the ceiling to create added interest within a space.
From the modern geometric designs of the GRAPHIS range or by
using colour such as the COLORTONE ranges through to the subtle
CIRRUS texture and designs, Armstrong has a wide range
of designs and colours to help sculpt the light in a space.
ULTIMA Vector
44
45
ULtIMA
Mineral Laminated > Board & tiles > ULtIMA
44%
87%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content
ultima
board
tegular
microlookbe
Vector
Prelude XL2/tLX 24 mm
Prelude Sixty2
Prelude XL2/tLX 24 mm
Prelude Sixty2
Prelude XL2/tL 15 mm
Silhouette XL2 15 mm
Interlude XL2 15 mm
Prelude XL2 24 mm
Prelude Sixty2
9.5mm
19mm
8mm
3mm
19mm
8mm
6mm
10mm
586mm
575mm
19mm
14mm
10mm
594mm
594mm
2254 M
600 x 600 x 19 mm
9536 M
9538 M
9843 M
3320 M
625 x 625 x 19 mm
9536 d
9538 d
9843 d
3320 d
675 x 675 x 19 mm
2743 M
600 x 1200 x 19 mm
9537 M
2734 M
2735 M
300 x 1200 x 19 mm
EN ISO 354 &
EN ISO 11654
Intelligibility
2mm
19mm
19mm
45°
500 x 500 x 19 mm
9964 M
aw
NRc 125 250 500 1000 2000 4000
• Board, tegular, MicroLook BE
0.70(H) 0,70 0.55 0.50 0.65 0.80 0.90 0.85
• vector
0.75(H) 0.75 0.50 0.55 0.70 0.85 0.95 0.95
Sound Absorption Class = C
1.0
Hz
aP
0.8
aP
0.6
0.4
aP
0.2
0
125
250
500
1 000
2 000
4 000
Octave Band centre frequency (Hz)
Dnfw
34 – 36 dB
EN ISO 10848-2
& EN ISO 717-1
Rw
18 dB
EN ISO 140-3
& EN ISO 717-1
EEA
OFFICE - Woningbouwvereniging Compaen (NL),
ULTIMA Vector
575mm
4.5mm
15°
ULtIMA is a high performance Armstrong
product which meets the most demanding
requirements by combining excellent
sound absorption, sound attenuation,
high light reflectance, good humidity
resistance and superior durability.
the ULtIMA texture is available in different
densities for mixed applications
(Standard, OP or dB).
Additionally, with its white unperforated
surface, ULtIMA’s elegant design makes
it ideal for today’s requirements and
demands.
■ Reinforced scratch resistant face
■ Extra durability and improved handling
■ Excellent acoustical qualities
■ Refined visual appearance
■ High light reflectance (= 87%)
■ Hard edge treatment
■ ULtIMA is also available in Planks
(see p. 49)
Light Reflectance
RUS
Euroclass A2-s1, d0
G1, v1, d1, t1 to FZ 123
EN 13501-1
l = 0.052 W/m K
95 % RH
15 YEAR
 5.2 kg/m2
guarantee
EN 12667
& ISO 8301
Note: Product availability may vary. Please contact AtS or visit our website for updated information or other sizes. detailed acoustical data are presented on pages 17-19 and our web page.
47
ULtIMA PLANKS
Mineral Laminated > Planks > ULtIMA
44%
87%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content
ultimaPlaNkS
Sl2
Light Reflectance
Intelligibility
k2c2
Prelude 24 mm Main Runner
Prelude Sixty2
System Z
System Z
12mm
9mm
19mm
11.5mm
11.3mm
13mm
A
2mm
17mm
9.5mm
17mm
19mm
B
26mm
300 x 1500 x 19 mm
9954 M
312,5 x 1500 x 19 mm
9957 d
300 x 1720 x 19 mm
2736 M
300 x 1800 x 19 mm
9955 M
312,5 x 1800 x 19 mm
9958 d
300 x 2500 x 19 mm
9956 M
312,5 x 2500 x 19 mm
EN ISO 354 &
EN ISO 11654
9959 d
a NRc 125 250 500 1000 2000 4000
0.70(H)
0.70 0.50 0.50 0.60 0.75 0.90 0.95
Sound Absorption Class = C
1.0
Hz
a
0.8
aP
0.6
0.4
0.2
0
125
Modern commercial construction often
has a requirement to reflect the building
module into the ceiling design, allowing
flexible segmentation of the interior.
Working in harmony with the existing
attributes of ULtIMA, ULtIMA Planks
provide an accessible solution for such
demands, as well as offering ideal
suitability for use in corridors.
4 000
Dnfw
40 dB
EN ISO 10848-2
& EN ISO 717-1
Rw
18 dB
EN ISO 140-3
& EN ISO 717-1
EEA
OFFICE - Kantoor Stam & De Koning Wessels (NL),
ULTIMA Planks SL2
250
500
1 000
2 000
Octave Band centre frequency (Hz)
RUS
Euroclass A2-s1, d0
G1, v1, d1, t1 to FZ 123
EN 13501-1
l = 0.052 W/m K
95 % RH
15 YEAR
 5.2 kg/m2
guarantee
EN 12667
& ISO 8301
Note: Product availability may vary. Please contact AtS or visit our website for updated information or other sizes. detailed acoustical data are presented on pages 17-19 and our web page.
49
ULtIMA OP
Mineral Laminated > Board & tiles > ULtIMA OP
42%
86%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content
ultimaoP
Light Reflectance
Concentration
board
tegular
microlook
Prelude XL2/tLX 24 mm
Prelude Sixty2
Prelude XL2/tLX 24 mm
Prelude Sixty2
Prelude XL2/tL 15 mm
Interlude XL2 15 mm
5mm
9.5mm
20mm
8mm
20mm
8mm
15°
ULtIMA OP is a new generation
of mineral fibre ceilings featuring the
latest Armstrong technology. this new
product range provides the highest level
of sound absorption (aw = 1.00). this
performance allied to the ULtIMA surface
design provides a superior blend of finely
textured visual, enhanced durability and
superb sound absorption.
From call centres to cafeterias this
product range can play a key part in
helping to reduce unwanted noise and
improve our general learning, living and
working conditions.
Also, with many office buildings and
working spaces minimising the use of
partitioned offices ULtIMA OP products
provide the highest levels of sound
absorption and light reflectance helping
to improve our working environment.
600 x 600 x 20 mm
2860 M
2862 M
2863 M
625 x 625 x 20 mm
2860 d
2862 d
2863 d
600 x 1200 x 20 mm
2861 M
EN ISO 354 &
EN ISO 11654
aw
NRc 125 250 500 1000 2000 4000
1.00
0.95 0.55 0.85 1.00 0.95 1.00 1.00
Sound Absorption Class = A
Hz
aP
20mm
15°
1.0
0.8
aP
0.6
0.4
0.2
0
125
250
500
1 000
2 000
4 000
Octave Band centre frequency (Hz)
Dnfw
26 dB
EN ISO 10848-2
& EN ISO 717-1
Rw
10 dB
EN ISO 140-3
& EN ISO 717-1
EEA
RUS
Euroclass A2-s1, d0
G1, v1, d1, t1 to FZ 123
EN 13501-1
EDUCATION - Luther-Meyer-Gymnasium (D),
ULTIMA OP Board
l = 0.037 W/m K
95 % RH
15 YEAR
 3.7 kg/m2
guarantee
EN 12667
& ISO 8301
Note: Product availability may vary. Please contact AtS or visit our website for updated information or other sizes. detailed acoustical data are presented on pages 17-19 and our web page.
51
ULtIMA dB
Mineral Laminated > tiles & Planks > ULtIMA dB
63%
87%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content
ultimadb
board
tegular
microlookbe
Prelude XL2/tLX 24 mm
Prelude Sixty2
Prelude XL2/tLX 24 mm
Prelude Sixty2
Prelude XL2/tL 15 mm
Silhouette XL2 15 mm
Interlude XL2 15 mm
9.5mm
23mm
8mm
Light Reflectance
Sl2
Prelude 24 mm Main Runner
Prelude Sixty2
9mm
4.5mm
23mm
3mm
8mm
23mm
System Z
17mm
11.5mm 19mm
13mm B
11.3mm
45°
15°
Confidentiality
A
26mm
Board & Tiles
600 x 600 x 23 mm
2038 M
2040 M
2041 M
625 x 625 x 23 mm
2038 d
2040 d
2041 d
Planks
ULtIMA dB offers a unique combination
of outstanding sound attenuation and
good sound absorption that enhances
privacy, comfort and workplace
effectiveness.
■ It can eliminate the need for sound
barriers in closed office applications.
■ Its white, smooth surface is reinforced
and scratch resistant.
■ It has a high level of light
reflectance (= 87%).
■ together with ULtIMA and
ULtIMA OP, ULtIMA dB is ideal
for mixed applications.
300 x 1500 x 19 mm
2046 M
300 x 1800 x 19 mm
2047 M
300 x 2500 x 19 mm
2049 M
EN ISO 354 &
EN ISO 11654
aw
NRc 125 250 500 1000 2000 4000
• Board, tegular, Microlook BE
0.65(H) 0.70 0.40 0.40 0.60 0.80 0.95 1.00
• SL2
0.60(H) 0.55 0.30 0.35 0.55 0.65 0.75 0.85
Sound Absorption Class = C
1.0
Hz
aP
0.8
aP
0.6
0.4
aP
0.2
0
125
250
500
1 000
2 000
Octave Band centre frequency (Hz)
4 000
Dnfw
40 - 43 dB
EN ISO 10848-2
& EN ISO 717-1
Rw
21 dB
EN ISO 140-3
& EN ISO 717-1
EEA
OFFICE - Acantus (NL),
ULTIMA dB Planks SL2
RUS
Euroclass A2-s1, d0
G1, v1, d1, t1 to FZ 123
EN 13501-1
l = 0.067 W/m K
95 % RH
15 YEAR
 8.1 kg/m2
guarantee
EN 12667
& ISO 8301
Note: Product availability may vary. Please contact AtS or visit our website for updated information or other sizes. detailed acoustical data are presented on pages 17-19 and our web page.
53
OPtIMA
Mineral Laminated > Board & tiles > OPtIMA
82%
87%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content
oPtima
Light Reflectance
board
tegular
microlook
Vector
Prelude XL2/tLX 24 mm
Prelude Sixty2
Prelude XL2/tLX 24 mm
Prelude Sixty2
Prelude XL2/tL 15 mm
Interlude XL2 15 mm
Prelude XL2 24 mm
Prelude Sixty2
9.5mm
15/20/25mm
8mm
4.5mm
15/20/25mm
8mm
15/20/25mm
6mm
22mm
10mm
586mm
575mm
2mm
22mm
14mm
10mm
594mm
Concentration
594mm
OPTIMA 15 mm
600 x 600 x 15 mm
2327 M
2329 M
2331 M
600 x 1200 x 15 mm
2328 M
2330 M
2332 M
2335 M
2349 M
2363 M
OPTIMA 20 mm
OPtIMA is a low density product with glass
wool as core material. Its white and strong
surface is obtained by the application of
an abrasion resistant paint on a glass fibre
face scrim. the Board edges are painted to
avoid the dispersion of fibres. to provide
excellent mechanical strength, all products
have a fibre glass fleece at the back and the
tegular & MicroLook edges are reinforced
and painted.
OPtIMA provides the highest levels of
sound absorption with an aw up to 1.00.
this makes it an ideal product for open
plan offices, cafeterias, or any other places
where too much noise can be disruptive.
Its fine textured white surface, similar
to the ULtIMA finish (see p. 47), makes it an
ideal solution in terms of aesthetics.
Furthermore, OPtIMA provides high light
reflectance and good cleanability.
the vector edge detail results from
Armstrong’s advanced technology.
It conceals the grid and gives the impression
that tiles are freely suspended from wall to
wall.In addition, OPtIMA ceilings are
available in a large variety of size
and edge detail combinations.
600 x 600 x 20 mm
600 x 1200 x 20 mm
2364 M
600 x 1800 x 20 mm
2337 M
1200 x 1200 x 20 mm
2338 M
2352 M
2366 M
OPTIMA 22 mm
600 x 600 x 22 mm
2387 M
600 x 1200 x 22 mm
3413 M
OPTIMA 25 mm
600 x 600 x 25 mm
EN ISO 354 &
EN ISO 11654
2379 M
aw
NRc 125 250 500
• Board, tegular, MicroLook 15 mm
0.90
0.90 0.35 0.75 1.00
• Board, tegular, MicroLook 20 mm
0.95
0.95 0.40 0.80 1.00
• Board, tegular, MicroLook 25 mm
1.00
1.00 0.50 0.85 1.00
• vector 22 mm
1.00
0.95 0.35 0.80 1.00
Sound Absorption Class = A
2381 M
1000 2000 4000
2383 M
1.0
Hz
0.80 0.90 0.95
aP
0.85 1.00 1.00
aP
0.95 1.00 1.00
aP
0.90 1.00 1.00
aP
0.8
aP
0.6
0.4
0.2
0
125
250
500
1 000
2 000
Octave Band centre frequency (Hz)
4 000
Rw
7 dB (OPtIMA 15 mm)
EN ISO 140-3
& EN ISO 717-1
EEA
EDUCATION - Primary School (F),
OPTIMA Vector
RUS
Euroclass A2-s1, d0
G1, v2, d1, t1 to FZ 123
EN 13501-1
l = 0.032 W/m K
95 % RH
15 YEAR
guarantee
EN 12667
& ISO 8301
15 mm: 1.8 kg/m2
20 mm: 2.3 kg/m2
22 mm: 2.9 kg/m2
25 mm: 2.8 kg/m2
Note: Product availability may vary. Please contact AtS or visit our website for updated information or other sizes. detailed acoustical data are presented on pages 17-19 and our web page.
55
PERLA
Mineral Laminated > Board & tiles > PERLA
45%
86%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content
Perla
Light Reflectance
board
tegular
microlookbe
Prelude XL2/tLX 24 mm
Prelude Sixty2
Prelude XL2/tLX 24 mm
Prelude Sixty2
Prelude XL2/tL 15 mm
Silhouette XL2 15 mm
Interlude XL2 15 mm
4.5mm
9.5mm
17mm
8mm
17mm
3mm
8mm
600 x 600 x 17 mm
2801 M
2803 M
2804 M
625 x 625 x 17 mm
2801 d
2803 d
2804 d
600 x 1200 x 17 mm
2802 M
625 x 1250 x 17 mm
2802 d
aw
NRc 125 250 500 1000 2000 4000
0.65(H)
0.70 0.35 0.40 0.60 0.85 0.95 1.00
Sound Absorption Class = C
Hz
aP
17mm
45°
15°
EN ISO 354 &
EN ISO 11654
Intelligibility
1.0
0.8
aP
0.6
0.4
0.2
0
125
250
500
1 000
2 000
4 000
Octave Band centre frequency (Hz)
PERLA is a new, plain, flat textured
surface design from Armstrong.
the PERLA surface is available in
several densities for mixed applications
(Standard, OP or dB).
this product contains a winning balance
of higher sound absorption combined
with excellent sound attenuating
properties making the product ideal
for todays working and learning
environments. Included are a range of
edge details featuring Armstrongs edge
treatment process to enhance product
durability.
Dnfw
35 dB
EN ISO 10848-2
& EN ISO 717-1
Rw
18 dB
EN ISO 140-3
& EN ISO 717-1
EEA
RUS
Euroclass A2-s1, d0
G1, v1, d1, t1 to FZ 123
EN 13501-1
EDUCATION - Openbare Basisschool Olympus (NL),
PERLA Board
l = 0.052 W/m K
95 % RH
15 YEAR
4.7 kg/m2
guarantee
EN 12667
& ISO 8301
Note: Product availability may vary. Please contact AtS or visit our website for updated information or other sizes. detailed acoustical data are presented on pages 17-19 and our web page.
57
PERLA OP
Mineral Laminated > tiles & Planks > PERLA OP
42%
86%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content
PerlaoP
board
tegular
Prelude XL2/tLX 24 mm
Prelude Sixty2
Prelude XL2/tLX 24 mm
Prelude Sixty2
Light Reflectance
microlook
Concentration
Sl2
Prelude XL2/tL 15 mm
Interlude XL2 15 mm
Prelude 24 mm
Main Runner
Prelude Sixty2
System Z
4.5mm
9.5mm
18mm
8mm
9mm
18mm
8mm
15°
18mm
11.5mm 18mm
B
13mm
11.3mm
A
15°
26mm
Tiles
600 x 600 x 18 mm
2880 M
2882 M
2883 M
625 x 625 x 18 mm
2880 d
2882 d
2883 d
600 x 1200 x 18 mm
2881 M
Planks
300 x 1500 x 18 mm
3094 M
312,5 x 1500 x 18 mm
600 x 1500 x 18 mm
3092 M
300 x 1800 x 18 mm
3096 M
312,5 x 1800 x 18 mm
600 x 1800 x 18 mm
EN ISO 354 &
EN ISO 11654
3093 M
aw
NRc 125 250 500 1000 2000 4000
• Board, tegular, MicroLook
0.95
0.90 0.50 0.85 0.95 0.90 1.00 1.00
• SL2
0.95
0.90 0.45 0.85 0.95 0.90 0.95 1.00
Sound Absorption Class = A
1.0
Hz
aP
0.8
aP
0.6
0.4
aP
0.2
0
125
250
500
1 000
2 000
4 000
Octave Band centre frequency (Hz)
PERLA OP features the latest generation
of Armstrong technology to provide
excellent levels of sound absorption
(0.95 aw) along with a new plain, flat
textured surface design. this range
of products is ideal for those larger
spaces where control of noise is an
important consideration.
Dnfw
25 - 27 dB
EN ISO 10848-2
& EN ISO 717-1
Rw
10 dB
EN ISO 140-3
& EN ISO 717-1
OFFICE - Roden Town Hall (NL),
PERLA OP Tegular
EEA
RUS
Euroclass A2-s1, d0
G1, v1, d1, t1 to FZ 123
EN 13501-1
l = 0.037 W/m K
95 % RH
15 YEAR
 3.3 kg/m2
guarantee
EN 12667
& ISO 8301
Note: Product availability may vary. Please contact AtS or visit our website for updated information or other sizes. detailed acoustical data are presented on pages 17-19 and our web page.
59
PERLA dB
Mineral Laminated > tiles & Planks > PERLA dB
63%
90%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content
Perladb
board
Prelude XL2/tLX 24 mm
Prelude Sixty2
tegular
Light Reflectance
microlookbe
Prelude XL2/tLX 24 mm
Prelude Sixty2
Prelude XL2/tL 15 mm
Silhouette XL2 15 mm
Interlude XL2 15 mm
Confidentiality
Sl2
Prelude 24 mm
Main Runner
Prelude Sixty2
System Z
9mm
9.5mm
19mm
8mm
5mm
3mm
19mm
8mm
15°
45°
3192 M
3193 M
19mm
11.5mm 19mm
13mm B
11.3mm
A
26mm
Board & Tiles
600 x 600 x 19 mm
3191 M
Planks
300 x 1500 x 19 mm
3797 M
300 x 1800 x 19 mm
3798 M
300 x 2500 x 19 mm
3799 M
EN ISO 354 &
EN ISO 11654
PERLA dB offers a superb combination
of a smooth plain appearance and good
absorption and excellent levels of sound
attenuation.
this product range has been designed
to offer the very best combination
of acoustical performance for spaces
where room to room noise reduction
and confidentiality is important.
aw
NRc 125 250 500 1000 2000 4000
• Board, tegular, MicroLook BE
0.60(H) 0.65 0.30 0.40 0.55 0.70 0.85 0.95
Sound Absorption Class = C
• SL2
0.50(H) 0.50 0.30 0.35 0.40 0.60 0.70 0.80
Sound Absorption Class = D
aP
0.8
aP
0.6
0.4
0.2
aP
0
125
250
500
1 000
2 000
Octave Band centre frequency (Hz)
4 000
Dnfw
41 dB
EN ISO 10848-2
& EN ISO 717-1
Rw
21 dB
EN ISO 140-3
& EN ISO 717-1
EEA
OFFICE - Jahrsdörfer & Co (D),
PERLA dB Board
1.0
Hz
Euroclass A2-s1, d0
RUS
G1, v1, d1, t1 to FZ 123
EN 13501-1
l = 0.06 W/m K
95 % RH
15 YEAR
7.6 kg/m2
guarantee
EN 12667
& ISO 8301
Note: Product availability may vary. Please contact AtS or visit our website for updated information or other sizes. detailed acoustical data are presented on pages 17-19 and our web page.
61
SIERRA OP
Mineral Laminated > tiles & Planks > SIERRA OP
15%
83%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content
SierraoP
board
tegular
microlook
Prelude XL2/tLX 24 mm
Prelude Sixty2
Prelude XL2/tLX 24 mm
Prelude Sixty2
Prelude XL2/tL 15 mm
Interlude XL2 15 mm
Light Reflectance
Concentration
Sl2
Prelude 24 mm
Main Runner
Prelude Sixty2
System Z
5mm
9mm
9.5mm
17mm
17mm
15°
8mm
8mm
17mm
13mm
A
15°
17mm
11.5mm
11.3mm
B
26mm
Board & Tiles
600 x 600 x 17 mm
3780 M
3783 M
625 x 625 x 17 mm
3780 d
3783 d
3784 M
3784 d
675 x 675 x 17 mm
3785 M
600 x 1200 x 17 mm
3781 M
625 x 1250 x 17 mm
3781 d
Planks
300 x 1500 x 17 mm
3786 M
300 x 1800 x 17 mm
3787 M
600 x 1500 x 17 mm
3782 M
600 x 1800 x 17 mm
3796 M
EN ISO 354 &
EN ISO 11654
aw
NRc 125 250 500 1000 2000 4000
• Board & tiles
0.90
0.90 0.30 0.75 0.85 0.85 1.00 1.00
• Planks
0.90
0.85 0.50 0.75 0.85 0.85 1.00 1.00
Sound Absorption Class = A
1.0
Hz
aP
0.8
aP
0.6
0.4
aP
0.2
0
125
SIERRA OP features a plain surface
and utilises the latest generation
of Armstrong’s OP technology, to provide
high levels of sound absorption (0.90 aw).
250
500
1 000
2 000
Octave Band centre frequency (Hz)
4 000
Dnfw
26 - 29 dB
EN ISO 10848-2
& EN ISO 717-1
Rw
11 dB
EN ISO 140-3
& EN ISO 717-1
EEA
OFFICE - M&S Mode (NL),
SIERRA OP Planks
RUS
Euroclass A2-s1, d0
G1, v1, d1, t1 to FZ 123
EN 13501-1
l = 0.037 W/m K
95 % RH
15 YEAR
 3.7 kg/m2
guarantee
EN 12667
& ISO 8301
Note: Product availability may vary. Please contact AtS or visit our website for updated information or other sizes. detailed acoustical data are presented on pages 17-19 and our web page.
63
NEEvA
Mineral Laminated > tiles & Planks > NEEvA
20%
82%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content
NeeVa
Light Reflectance
board
tegular
microlook
Prelude XL2/tLX / cR 24 mm
Prelude Sixty2
Prelude XL2/tLX / cR 24 mm
Prelude Sixty2
Prelude XL2/tL 15 mm
Interlude XL2 15 mm
Silhouette XL2 15 mm
9.5mm
15/18mm
8mm
Concentration
4.5mm
18mm
8mm
18mm
Tiles NEEVA 15 mm
600 x 600 x 15 mm
2691 M
600 x 1200 x 15 mm
2692 M
Tiles NEEVA 18 mm
600 x 600 x 18 mm
2404 M
625 x 625 x 18 mm
2404 d
600 x 1200 x 18 mm
2405 M
625 x 1250 x 18 mm
2405 d
1200 x 1200 x 18 mm
2406 M
2414 M
2423 M
2415 M
2424 M
2416 M
Planks NEEVA 18 mm
NEEvA is a low density product with rock
wool as the core material. the face scrim
is made of glass fibre with a bright white
paint. the product is also available in
eight trendy colours.
the Board edges are painted to avoid
the dispersion of fibres.
tegular and MicroLook products are
reinforced due to a higher density
and the strong paint on the edges which
improves the mechanical strength.
All products have a fibre glass fleece
on the back to add additional strength.
NEEvA achieves excellent sound
absorption with an aW up to 1.00.
Many size and edge detail combinations
offer extensive design opportunities.
300 x 1800 x 18 mm
2408 M
600 x 1800 x 18 mm
2407 M
cOLORtONE NEEvA : Black (BK), cement (cG), Navy (NY), Metal (Mt), Perl (PF), carrara (cA) Amber (AB), Jade (JA).
Please refer to page 81.
EN ISO 354 &
EN ISO 11654
aw
NRc 125 250 500
• NEEvA Board 15 mm
1.00
0.95 0.40 0.90 1.00
• NEEvA Board 18 mm
1.00
0.95 0.40 0.85 1.00
• NEEvA tegular, MicroLook 18 mm
0.90
0.85 0.40 0.75 0.85
Sound Absorption Class = A
1000 2000 4000
Hz
0.90 1.00 1.00
aP
0.90 1.00 0.95
aP
0.85 0.95 0.95
aP
1.0
0.8
aP
0.6
0.4
0.2
0
125
250
500
1 000
2 000
Octave Band centre frequency (Hz)
4 000
Dncw
24 - 27 dB
EN 20140-9
& EN 717-1
Rw
7 dB (NEEvA 15 mm)
OFFICE - Dutch Technology (NL),
NEEVA Board 1200x1200
EN ISO 140-3
& EN ISO 717-1
EEA
Euroclass A1 (White)
RUS
G1, v2, d1, t1 to FZ 123
EN 13501-1
l = 0.033 W/m K
95 % RH
15 YEAR
guarantee
EN 12667
& ISO 8301
Board (15 mm)  1.20 kg/m2
Board (18 mm)  1.26 kg/m2
tegular & MicroLook (18 mm)  2.52 kg/m2
Note: Product availability may vary. Please contact AtS or visit our website for updated information or other sizes. detailed acoustical data are presented on pages 17-19 and our web page.
65
SAHARA
MineralnonLaminated>Board&Tiles>SAHARA
up to
41%
85%
EN ISO
ISO 14021
7742-2 & 3
Recycled Content
SAHARA
boARd
tegulAR
PreludeXL2/TLX24mm PreludeXL2/TLX24mm
PreludeSixty2
PreludeSixty2
micRolook
PreludeXL2/TL15mm
InterludeXL215mm
15mm
15mm
15°
micRolookbe
8mm
6.5mm(M)
7.5mm(D)
PreludeXL224mm
PreludeSixty2
575mm
5mm
15mm
3mm
15°
8mm
15mm
19mm
10mm
45°
Intelligibility
VectoR
PreludeXL2/TL15mm
SilhouetteXL215mm
InterludeXL215mm
5mm
9.5mm
Light Reflectance*
594mm
586mm
6mm
19mm
10mm
575mm
2mm
594mm
14mm
Sahara Perforated
600x600x15mm
2516M
2518M
2519M
625x625x15mm
2516D
2518D
2519D
2524M
600x600x19mm
675x675x15mm
2520M
2521M
2690M
2522M
2731M
600x1200x15mm
2517M
625x1250x15mm
2517D
300x1200x15mm
2730M
600x600x15mm
2610M
2612M
2613M
625x625x15mm
2610D
3322M
Sahara Unperforated
COLORTOneDune:Opal(OL),Carrara(CA),Platinum(Pn),Toledo(TO),BlueMountain(BT).
Pleaserefertopage81.
TheDunefamilyfeaturesamicroperforated,
finelygranulatedsurfacetextureandis
availableinawidevarietyofsizeandedge
details.SAHARA,SAHARAMAX/SABBIA
willallowyoutofindasolutiontoyour
requirementswhateveryourtechnical
constraints.
TheDunerangeoffersimproveddurability
andenhancedacousticalabsorption.
enISO354&
enISO11654
enISO10848-2
&enISO717-1
aw
nRC 125 250 500 1000 2000 4000
• SAHARA(Board,Tegular,MicroLook,MicroLookBe)
0.60
0.55 0.45 0.40 0.55 0.65 0.65 0.60
• SAHARAVector
0.65
0.65 0.45 0.50 0.60 0.70 0.70 0.55
• SAHARAunperforated(Board,Tegular,MicroLook)
0.10(L) 0.15 0.30 0.20 0.10 0.10 0.10 0.20
Sound Absorption Class = C (perforated)
Sound Absorption Class = not classified (unperforated)
Dncw
34 dB(SAHARAandSAHARAunperforated)
Dnfw
35 dB(SAHARAVector)
1.0
hz
aP
0.8
aP
0.6
0.4
aP
0.2
0
aP
125
250
500
1000
2000
4000
Octave Band centre frequency (Hz)
Rw
17 dB
EDUCATION - Amsterdam School of Real Estate (NL),
SAHARA Tegular
enISO140-3
&enISO717-1
eeA
SAHARA Unperforated
RuS
euroclassA2-s1,d0
KM1(G1,V1,D1,T1)FZ123
en13501-1
l=0.06W/mK
95%RH
15 YEAR
guarantee
3.9kg/m2
en12667
&ISO8301
*SAHARA=84%,SAHARAandSAHARAunperforated=85%
Note:Productavailabilitymayvary.PleasecontactATSorvisitourwebsiteforupdatedinformationorothersizes.Detailedacousticaldataarepresentedonpages17-19andourwebpage.
67
SAHARAPLAnKS
MineralnonLaminated>Planks>SAHARA
43%
84%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content
SAHARAPlANkS
boARd
Light Reflectance
Sl2
PreludeXL2/TLX24mm
PreludeSixty2
Intelligibility
k2c2
Prelude24mmMainRunner
PreludeSixty2
SystemZ
SystemZ
12mm
9mm
17mm
11.5mm
11.3mm
13mm
A
17mm
9.5mm
17mm
B
26mm
300x1500x17mm
2315M
2310M
300x1800x17mm
2316M
2312M
300x2500x17mm
2317M
2318M
312,5x2500x17mm
300x1720x17mm
ArmstrongPlanksystemsallowtheceiling
tointegratewiththebuildingmoduleand
whenfeaturingtheSL2edgedetailthese
systemsprovidefullaccessibilitywhilst
minimisingthevisiblegrid.Combining
excellentsoundabsorptionandsound
attenuationperformance,ourSAHARA
Planksrangealsooffersavarietyofsizes
tosuittheflexiblerequirementsofmodern
officebuildings.
SAHARAPlanksalsoprovideasolution
forcorridorareaswherethedifferentlengths
canaccomodateavarietyofcorridorwidths
whilstretainingaccessandprovidinghigh
levelsoflightreflectanceandsound
absorption.
enISO354&
enISO11654
2728M
2311M
aw
nRC 125 250 500 1000 2000 4000 hz
0.60
0.55 0.35 0.45 0.60 0.65 0.55 0.45 aP
Sound Absorption Class = C
2548D
1.0
0.8
aP
0.6
0.4
0.2
0
125
enISO10848-2
&enISO717-1
Dncw
34 dB(SAHARABoardPlanks)
Dnfw
39 dB(SAHARASL2,K2C2Planks)
Rw
17 dB
250
500
1000
2000
Octave Band centre frequency (Hz)
4000
enISO140-3
&enISO717-1
eeA
OFFICE - UNIJA Raãunovodska hi‰a d.d. (SLO),
SAHARA Planks SL2
RuS
euroclassA2-s1,d0
KM1(G1,V1,D1,T1)FZ123
en13501-1
l=0.06W/mK
95%RH
15 YEAR
guarantee
5.5kg/m2
en12667
&ISO8301
Note:Productavailabilitymayvary.PleasecontactATSorvisitourwebsiteforupdatedinformationorothersizes.Detailedacousticaldataarepresentedonpages17-19andourwebpage.
69
SAHARAMAX/SABBIA
MineralnonLaminated>Board&Tiles>SAHARAMAX/SABBIA
42%
84%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content
SAHARAmAX/SAbbiA
Light Reflectance
boARd
tegulAR
micRolook
PreludeXL2/TLX24mm
PreludeSixty2
PreludeXL2/TLX24mm
PreludeSixty2
PreludeXL2/TL15mm
InterludeXL215mm
4.5mm
9.5mm
18mm
18mm
600x600x18mm
2103M
600x1200x18mm
2104M
enISO354&
enISO11654
8mm
6.5mm(M)
7.5mm(D)
15°
18mm
15°
2260M
aw
nRC 125 250 500 1000 2000 4000 hz
0.65
0.65 0.50 0.55 0.75 0.75 0.70 0.45 aP
Sound Absorption Class = C
Concentration
2261M
1.0
0.8
aP
0.6
0.4
0.2
0
125
250
500
1000
2000
4000
Octave Band centre frequency (Hz)
Dncw
35 dB
Rw
17 dB
en20140-9
&en717-1
Theworldofeducationrequiresceilingswith
goodlevelsofsoundabsorptionandsound
attenuation.SAHARAMAX/SABBIA
combinesthetwoperformances,which
optimisethequalityoflisteningwhile
eliminatingthenoisecomingfromtheother
rooms.
Featuringthehighlypopularlightly
granulatedtexture,SAHARAMAX/SABBIA
providesanidealsolutionforclassroomand
generalteachingconditions.
enISO140-3
&enISO717-1
eeA
RuS
euroclassA2-s1,d0
KM1(G1,V1,D1,T1)FZ123
en13501-1
EDUCATION - Medisch Centrum (NL),
SAHARA MAx / SAbbIA board
l=0.06W/mK
95%RH
15 YEAR
guarantee
4.16kg/m2
en12667
&ISO8301
Note:Productavailabilitymayvary.PleasecontactATSorvisitourwebsiteforupdatedinformationorothersizes.Detailedacousticaldataarepresentedonpages17-19andourwebpage.
71
SAHARAdB
MineralnonLaminated>Board&Tiles>SAHARAdB
61%
84%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content
SAHARAdb
Light Reflectance
boARd
tegulAR
micRolookbe
PreludeXL2/TLX24mm
PreludeSixty2
PreludeXL2/TLX24mm
PreludeSixty2
PreludeXL2/TL15mm
SilhouetteXL215mm
InterludeXL215mm
4.5mm
9.5mm
6.5mm
15°
600x600x19mm
enISO354&
enISO11654
3mm
19mm
19mm
2990M
8mm
19mm
45°
2992M
aw
nRC 125 250 500 1000 2000 4000 hz
0.60
0.55 0.35 0.40 0.55 0.65 0.65 0.65 aP
Sound Absorption Class = C
Confidentiality
2994M
1.0
0.8
aP
0.6
0.4
0.2
0
125
250
500
1000
2000
4000
Octave Band centre frequency (Hz)
Dnfw
39 dB
Rw
20 dB
enISO10848-2
&enISO717-1
Thisproductrangeoffersexcellentsound
attenuation(dBsoundreduction)along
withgoodlevelsofsoundabsorption.
Itcanalsoeliminatetheneedforsound
barriersinclosedofficeapplications.
Whenusedtogetherwiththetraditional
Dunerangesyoumixandmatch
acousticalperformancesaccording
toyourpreciseneeds-allwiththesame
classicfinelytextureddesign.
enISO140-3
&enISO717-1
eeA
RuS
euroclassA2-s1,d0
KM1(G1,V1,D1,T1)FZ123
en13501-1
l=0.067W/mK
OFFICE - Kanzlei Jahrsdörfer & Kollegen (D),
SAHARA db board
95%RH
15 YEAR
7.8kg/m2
guarantee
en12667
&ISO8301
Note:Productavailabilitymayvary.PleasecontactATSorvisitourwebsiteforupdatedinformationorothersizes.Detailedacousticaldataarepresentedonpages17-19andourwebpage.
73
CIRRuS-CIRRuSMAX/CIRRuS75
MineralnonLaminated>Board&Tiles>CIRRuS-CIRRuSMAX/CIRRuS75
≤ 65%
ISO 14021
Recycled Content*
ciRRuS
boARd
tegulAR
PreludeXL2/TLX24mm
PreludeSixty2
PreludeXL2/TLX24mm
PreludeSixty2
15mm
15mm
15°
8mm
6.5mm(M)
7.5mm(D)
Light Reflectance
Intelligibility
micRolook
micRolookbe
PreludeXL2/TL15mm
InterludeXL215mm
PreludeXL2/TL15mm
SilhouetteXL215mm
InterludeXL215mm
5mm
10mm
9.5mm
83%
EN ISO
7742-2 & 3
22mm
8mm
5mm
15mm
15°
15°
3mm
8mm
15mm
45°
CIrrUS
600x600x15mm
9619M
9620M
625x625x15mm
9619D
9620D
9621D
9622M
CIrrUS MaX / CIrrUS 75
600x600x22mm
enISO354&
enISO11654
9290M
aw
nRC 125 250 500 1000 2000 4000 hz
• CIRRuS
0.55(H) 0.50 0.35 0.40 0.45 0.55 0.60 0.70 aP
Sound Absorption Class = D
• CIRRuSMAX/CIRRuS75
0.70(H) 0.75 0.40 0.40 0.70 0.90 1.00 1.00 aP
Sound Absorption Class = C
1.0
0.8
aP
0.6
0.4
0.2
0
125
250
500
1000
2000
4000
Octave Band centre frequency (Hz)
CIRRuStilesprovideawarm,smooth
texturedvisualalongwithgoodacoustical
propertiesandarangeofedgedetails
particularlysuitedtothedesignerrange
ofgridsystems.
CIRRuSMAX/CIRRuS75tilesprovide
ahighlevelofsoundabsorption,whilst
featuringadelicatetextureofcontemporary
design.Themicroperforationsarevirtually
imperceptablewheninstalled.
en20140-9
&en717-1
Dncw
36 dB(CIRRuS)
38 dB(CIRRuSMAX/CIRRuS75)
eeA
euroclassA2-s1,d0(CIRRuS)
euroclassA2-s2,d0(CIRRuSMAX/CIRRuS75)
KM1(G1,V1,D1,T1)FZ123
en13501-1
l=0.06W/mK
EDUCATION - St John College (UK),
CIRRUS MicroLook
RuS
95%RH
15 YEAR
guarantee
CIRRuS  4.0kg/m2
CIRRuSMAX/CIRRuS75 6.5kg/m2
en12667
&ISO8301
*RecycledContent:33%CIRRuS-65%CIRRuSMAX/CIRRuS75
Note:Productavailabilitymayvary.PleasecontactATSorvisitourwebsiteforupdatedinformationorothersizes.Detailedacousticaldataarepresentedonpages17-19andourwebpage.
75
PLAIn
MineralnonLaminated>Board&Tiles>PLAIn
36-44%
87%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content
PlAiN
Light Reflectance
boARd
tegulAR
micRolook
PreludeXL2/TLX24mm
PreludeSixty2
PreludeXL2/TLX24mm
PreludeSixty2
PreludeXL2/TL15mm
InterludeXL215mm
4.5mm
9.5mm
15mm
15mm
8mm
6.5mm(M)
7.5mm(D)
15°
600x600x15mm
9587M
9589M
9590M
625x625x15mm
9587D
9589D
9590D
600x1200x15mm
9588M
625x1250x15mm
9588D
enISO354&
enISO11654
aw
nRC 125 250 500 1000 2000 4000 hz
0.15(L)
0.15 0.30 0.25 0.15 0.10 0.15 0.25 aP
Sound Absorption Class = E
15mm
15°
1.0
0.8
aP
0.6
0.4
0.2
0
125
250
500
1000
2000
Octave Band centre frequency (Hz)
4000
Dncw
37 dB
en20140-9
&en717-1
ThesmoothwhitesurfaceofPLAInmeets
today’strendsforcleanerfinisheswhilst
maximisinglightreflectanceforrooms
featuringuplightersandindirectlighting,
resultingincostsavingsandincreased
levelsofcomfort.
eeA
RuS
euroclassA2-s1,d0
KM1(G1,V1,D1,T1)FZ123
en13501-1
l=0.06W/mK
95%RH
15 YEAR
4kg/m2
guarantee
RETAIL - Rostock (D),
PLAIN board
en12667
&ISO8301
Note:Productavailabilitymayvary.PleasecontactATSorvisitourwebsiteforupdatedinformationorothersizes.Detailedacousticaldataarepresentedonpages17-19andourwebpage.
77
FIneFISSuReD
MineralnonLaminated>Board&Tiles>FIneFISSuReD
39-51%
85%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content
FiNeFiSSuRed
Light Reflectance
boARd
tegulAR
micRolook
PreludeXL2/TLX24mm
PreludeSixty2
PreludeXL2/TLX24mm
PreludeSixty2
PreludeXL2/TL15mm
InterludeXL215mm
4.5mm
9.5mm
15mm
15mm
8mm
6.5mm(M)
7.5mm(D)
15°
Intelligibility
15mm
15°
600x600x15mm
9121M*
9122M
9202M
625x625x15mm
9121D
9122D
9202D
600x1200x15mm
9120M
*Colours:Squareedgeboard600x600mmisavailableinBlack(BK).
enISO354&
enISO11654
aw
nRC 125 250 500 1000 2000 4000 hz
0.60(H)
0.60 0.40 0.40 0.55 0.75 0.75 0.75 aP
Sound Absorption Class = C
1.0
0.8
aP
0.6
0.4
0.2
0
125
Dncw
34 dB
Thenon-directionalFIneFISSuReD
surfaceisdesignedforeffectivesound
absorption.
250
500
1000
2000
Octave Band centre frequency (Hz)
4000
en20140-9
&en717-1
eeA
eeA
RuS
euroclassA2-s1,d0
euroclassA2-s2,d0(Black)
KM1(G1,V1,D1,T1)FZ123
en13501-1
OFFICE, FINE FISSURED Tegular
l=0.06W/mK
95%RH
15 YEAR
 3.5kg/m2
guarantee
en12667
&ISO8301
FINE FISSURED black
Note:Productavailabilitymayvary.PleasecontactATSorvisitourwebsiteforupdatedinformationorothersizes.Detailedacousticaldataarepresentedonpages17-19andourwebpage.
79
COLORTONE
MineralDecorative>Board&Tiles>COLORTONE
≤ 48%
ISO 14021
Recycled Content*
COLORTONE DUNE
Intelligibility
CARRARA (CA)
PLATINUM (PN)
BLUE MOUNTAIN (BT)
600x600x15mm
9095MCA
9095MPN
9095MBT
600x1200x15mm
9090MCA
9090MPN
9090MBT
9163MCA
9163MPN
9163MBT
9113MCA
9113MPN
9113MBT
Board
Tegular
600x600x15mm
MicroLook
600x600x15mm
COLORTONE NEEVA
BLACk (Bk) CEMENT (Cg)
NAVy (Ny)
METAL (MT) CARRARA (CA)
PERL (Pf)
AMBER (AB)
jADE (jA)
2695MJA
Board
600x600x15mm
2695MBK
2695MCG
2695MNY
2695MMT
2695MCA
2695MPF
2695MAB
625x625x18mm
2404DBK
2404DCG
2404DNY
2404DMT
2404DCA
2404DPF
2404DAB
2404DJA
600x1200x15mm
2696MBK
2696MCG
2696MNY
2696MMT
2696MCA
2696MPF
2696MAB
2696MJA
625x1250x18mm
2405DBK
2405DCG
2405DNY
2405DMT
2405DCA
2405DPF
2405DAB
2405DJA
COLORTONEDUNE-Colours:Carrara(CA),Platinium(PN),BlueMountain
(BT).
COLORTONENEEVA-Colours:Black(BK),Cement(CG),Navy(NY),
Metal(MT),Perl(PF),Carrara(CA),Amber(AB),Jade(JA).
AllArmstrongmineralceilingsare
availableinwhite.Inadditionweoffer
arangeofoptionsforspecifierswhowish
tointroducecoloursinBoard,Tegular
orMicroLookedgedetails.
COLORTONEoffersasimplewaytoplay
withcoloursinceilings,availableinDUNE
orNEEVAsurfacestosuityouracoustic
requirements.
LEISURE - Cinema (UK),
CoLoRtonE nEEva Black
ENISO354&
ENISO11654
EN20140-9
&EN717-1
aw
NRC 125 250 500 1000
• COLORTONEDUNE
0.55
0.55 0.40 0.40 0.50 0.60
Sound Absorption Class = D
• COLORTONENEEVA(Board15mm)
1.00
0.95 0.40 0.90 1.00 0.90
• COLORTONENEEVA(Board18mm)
1.00
0.95 0.40 0.85 1.00 0.90
Sound Absorption Class = A
EN13501-1
1.0
2000 4000 Hz
0.55 0.45
0.8
aP
aP
0.6
0.4
0.2
1.00 1.00
aP
1.00 0.95
aP
0
125
Dncw
35 dB(COLORTONEDUNE)
24 dB(COLORTONENEEVA18mm)
EEA
Note:TrulokPreludesuspensionsystemsareavailableinfollowingstandard
colours:Carrara(CA),Black(BK),SilverGreyRAL9006(SG),Brass(BS),
Chrome(CE),Brown(BN),WhiteRAL9010(WR).
Achoiceofover180RALcoloursareavailableasaspecialorder.
EuroclassA2-s1,d0(COLORTONEDUNE)
E uroclassA1(COLORTONENEEVABlack,Navy,Perl,Carrara,
Amber,Jade)
l=0.06W/mK(COLORTONEDUNE)
l=0.033W/mK(COLORTONENEEVABoard)
EN12667
&ISO8301
ENISO140-3
&ENISO717-1
250
500
1000
2000
Octave Band centre frequency (Hz)
4000
Rw
17 dB(COLORTONEDUNE)
7 dB(COLORTONENEEVA)
EuroclassA2-s1,d0(COLORTONENEEVACement)
EuroclassA2-s2,d0(COLORTONENEEVAMetal)
95%RH
COLORTONEDUNE3.9kg/m2
COLORTONENEEVA(Board15mm)1.20kg/m2
COLORTONENEEVA(Board18mm)1.26kg/m2
*RecycledContent:48%COLORTONEDUNE-20%COLORTONENEEVA
Note:Productavailabilitymayvary.PleasecontactATSorvisitourwebsiteforupdatedinformationorothersizes.Detailedacousticaldataarepresentedonpages17-19andourwebpage.
81
DESIGNCIRRUS
MineralDecorative>Board&Tiles>DESIGNCIRRUS
33%
83%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content
DEsIgN CIRRUs
Light Reflectance
Intelligibility
IMAgE
52mm
15mm
MICROLOOk
PreludeXL2/TL15mm
15mm
4.7mm
52mm
15mm
5mm
600x600x15mm
ENISO354&
ENISO11654
6.5mm
8406M
aw
NRC 125 250 500 1000 2000 4000 Hz
0.55(H)
0.55 0.35 0.40 0.45 0.60 0.75 0.85 aP
Sound Absorption Class = D
1.0
0.8
aP
0.6
0.4
0.2
0
125
Thisgeometricproductallowseasy
integrationforavarietyofservices.
Inaddition,itmakeseffectiveuseof
itsexclusivepatternbydisguising
thegridsystem;thusmakingitappear
partoftheoverallceilingdesign.
Dncw
36 dB
250
500
1000
2000
Octave Band centre frequency (Hz)
4000
EN20140-9
&EN717-1
EEA
EuroclassA2-s1,d0
RUS
KM1(G1,V1,D1,T1)FZ123
EN13501-1
REtaIL - Cafeteria,
CIRRUS Step
l=0.06W/mK
70%RH
4kg/m2
EN12667
&ISO8301
Note:Productavailabilitymayvary.PleasecontactATSorvisitourwebsiteforupdatedinformationorothersizes.Detailedacousticaldataarepresentedonpages17-19andourwebpage.
83
CONTRASTCIRRUS
MineralDecorative>Board&Tiles>CONTRASTCIRRUS
33%
83%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content
CONTRAsT CIRRUs
MICROLOOk
Light Reflectance
CIRCLEs
Intelligibility
sqUAREs
6mmØ
PreludeXL2/TL15mm
InterludeXL215mm
39.5mm
40mm
15mm
4.5mm
8mm
15mm
15°
600x600x15mm
ENISO354&
ENISO11654
aw
NRC 125 250 500 1000 2000 4000 Hz
0.55
0.50 0.40 0.40 0.45 0.55 0.60 0.65 aP
Sound Absorption Class = D
9902M
9903M
1.0
0.8
aP
0.6
0.4
0.2
0
125
Dncw
36 dB
250
500
1000
2000
4000
Octave Band centre frequency (Hz)
EN20140-9
&EN717-1
ThegeometricpatternsofContrastCircles,
Squaresarerecommendedforareasrequiring
goodacousticalabsorption,combinedwith
aestheticalqualities.
EEA
EuroclassA2-s1,d0
RUS
KM1(G1,V1,D1,T1)FZ123
EN13501-1
l=0.06W/mK
95%RH
4kg/m2
EN12667
&ISO8301
ContRaSt Circles
Note:Productavailabilitymayvary.PleasecontactATSorvisitourwebsiteforupdatedinformationorothersizes.Detailedacousticaldataarepresentedonpages17-19andourwebpage.
85
GRAPHIS
MineralDecorative>Board&Tiles>GRAPHIS
Puntos,Cuadros,Linear,Neocubic,Diagonal,MixA&B
51%
92%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content
Light Reflectance
Confidentiality
gRAPHIs
PUNTOs
CUADROs
LINEAR
NEOCUBIC
DIAgONAL
MIx A
MIx B
39.5mm
15mm
MICROLOOk
PreludeXL2/TL15mm
4mm
4mm
R6.5mm
30°
600x600x17mm
ENISO354&
ENISO11654
9900M
R6.4mm
17mm
9901M
17mm
30°
6.5mm
9220M
aw
NRC 125 250 500 1000 2000 4000 Hz
0.15(L)
0.15 0.35 0.20 0.10 0.10 0.15 0.25 aP
Sound Absorption Class = E
4mm
R1.5mm
30°
6.4mm
9221M
9222M
17mm
6.4mm
9223M
9224M
1.0
0.8
aP
0.6
0.4
0.2
0
Dncw
36 dB
125
250
500
1000
2000
Octave Band centre frequency (Hz)
4000
EN20140-9
&EN717-1
Thecrisp,plasterlikedesignofGRAPHIS
PuntosandCuadros,issuitablefor
areasrequiringhighlightreflectance
andasoothingatmosphere.
Unobtrusivelythesedesignsaddaquiet
elegancetoyourrequiredfinish,andare
particularlysuitedtoareassuchasreceptions,
shops,concoursesorconferencerooms.
EEA
EuroclassA2-s2,d0
RUS
KM1(G1,V1,D1,T1)FZ123
EN13501-1
l=0.06W/mK
70%RH
6kg/m2
EN12667
&ISO8301
offICE - BDo Rotterdam (nL),
GRaphIS
Note:Productavailabilitymayvary.PleasecontactATSorvisitourwebsiteforupdatedinformationorothersizes.Detailedacousticaldataarepresentedonpages17-19andourwebpage.
87
VISUAL
MineralDecorative>Opencell>VISUALV49,V64
71%
ISO 14021
Recycled Content
VIsUAL
V49
Intelligibility
V64
A
C
A
A/58mm
B/15mm
C/6.35mm
Openarea:45.6%
Cutoffangle:18°
B
C
A/47.20mm
B/15mm
C/6.35mm
Openarea:39.6%
Cutoffangle:22°
B
MICROLOOk
MICROLOOk
PreludeXL2/TL15mm
PreludeXL2/TL15mm
4.5mm
10mm
600x600x19mm
Armstrong’sVISUALceilingsareavailable
intwoopencelloptionsandaredesigned
forinstallationon15mmsuspension
systems.Aswellasenhancingtheceiling
design,productintegrationcanbearranged
toprovidespecificacousticrequirementsin
areassuchasconferenceormeetingrooms.
Visualtilesprovideamonolithicceiling
appearanceandeffectivelyintegratewith
recessedluminaires,custom-made
downlightersandairhandlingdiffusers.
ENISO354&
ENISO11654
19mm
10mm
8580M
aw
NRC 125 250 500 1000 2000 4000 Hz
• V49+fleece
0.50(H)
0.50 0.10 0.30 0.40 0.50 0.75 0.90 aP
Sound Absorption Class = D
• V49+fleece+25mmx20kg/m3fibreglassoverlay
0.95
0.90 0.35 0.80 0.95 0.90 1.00 1.00 aP
Sound Absorption Class = A
EEA
4.5mm
EuroclassA2-s1,d0(withoutoverlay)
19mm
8581M
1.0
0.8
aP
0.6
0.4
0.2
0
125
RUS
250
500
1000
2000
Octave Band centre frequency (Hz)
4000
KM1(G1,V1,D1,T1)FZ123
EN13501-1
REtaIL - City loung (nL)
vISUaL v49
70%RH
4kg/m2
Note:Productavailabilitymayvary.PleasecontactATSorvisitourwebsiteforupdatedinformationorothersizes.Detailedacousticaldataarepresentedonpages17-19andourwebpage.
89
BIOGUARD RAnGe
■
Bioguard is a special surface paint applied to Armstrong mineral and metal tiles.
■
Bioguard provides active protection against bio-contamination.
■
■
■
■
■
SPECIFIC SOlUTIONS
■
■
■
Bioguard inhibit the growth of bacteria, mould and yeast, such as MRSA, E-coli,
Streptococcus Pneumoniae, Bacillus Cereus, Aspergillus Niger, Candida Albicans,
Klebsiella Pneumoniae, Acinebacter Baumanii.
• The kill rate of these micro-organisms is 99.9% in less than 72 hours. (Tested
against JIS Z2801 and NF S 90-351).
• BIOGUARD solutions are active against the micro-organisms that land on the surface
of the tile.
• There is no radiation or spread of chemicals in the air.
• They are harmless for people, animals and plants.
• They are active during the life-time of the ceiling as long as the surface is intact.
Protection against Biocontamination
iSo 5 Clean room performance for BIOGUARD PlAIN, BIOGUARD ACOUSTIC
and ORCAl BIOGUARD Extra Microperforated with fleece and Premium B15 (tested
against ISO 14644-1).
ISO Clean Room
iSo 3 Clean room performance for ORCAl BIOGUARD Plain (tested against
ISO 14644-1).
The very smooth surface of BIOGUARD PlAIN, BIOGUARD ACOUSTIC and
ORCAl BIOGUARD limits the accumulation of dust and micro-organisms (Kinetic of
Decontamination test against NF S 90-351).
BIOGUARD products provide excellent water-repellency allowing frequent cleaning.
BIOGUARD products can be cleaned with diluted disinfectants containing active
agents such as Quaternary Ammonium, Hydrogen Peroxide and Chlorine.
BIOGUARD PlAIN, BIOGUARD ACOUSTIC and ORCAl BIOGUARD Plain are
suitable for use in category 2 - 6 areas as defined in HTM 60.
100% rH performance for ORCAl BIOGUARD Plain when painted front and back.
■ BIOGUARD
Resistance to disinfectants
■ PARAFON
HYGIEN (ISO 5)
■ ClEAN ROOM Fl (ISO 5)
■ CERAMAGUARD (100% RH)
■ NEWTONE (100% RH)
MINERAL
Bioguard for Healthcare environments
The BIOGUARD paint applied to mineral
and metal tiles provides anti-microbial and
clean room performance as well as good
cleanability and resistance to disinfectants.
■
■ CorroSioN rESiSTaNT grid
Our corrosion resistant grid is galvanised
and organically coated in accordance with
Durability – Class of Exposure Class C
(EN 13964: table 8). In addition it has been
tested for salt spray corrosion in accordance
with EN ISO 9227 and achieved over
700 hours resistance.
ParaFoN HYgiEN for Clean rooms
and Kitchens
Suitable for high pressure water cleaning
and providing high sound absorption the
product is particularly adapted to greasy
and noisy environments such as kitchens.
The ISO 5 performance makes the product
suitable for clean rooms.
■
Bioguard
aCouSTiC
orCal Bioguard
Extra
microperforated
with fleece and
Premium B15
orCal Bioguard
Plain
ClEaN room
grid
Category
2, 3, 4, 5, 6
Category
2, 3, 4, 5, 6
Category
2, 3, 4, 5, 6
Category
1*, 2, 3, 4, 5, 6
Category
2, 3, 4, 5, 6
Zone 1, 2 & 3
Zone 1, 2 & 3
Zone 1, 2 & 3
Zone 1, 2, 3 & 4
Zone 1, 2 & 3
Particle emission class
ISO 5
ISO 5
ISO 5
ISO 3
ISO 4
Material
Mineral
Mineral
Steel with acoustic
fleece and mineral
fibre infill
Steel
Aluminium
Washable with a
damp sponge
Washable with a
damp sponge
Washable with a
damp sponge
High pressure**
water cleaning
Washable with a
damp sponge
Classification NF S 90-351
ClEaN room Fl
The surface and edges are sealed with
a polyester film which doesn’t attract dust
and can be washed regularly. The product
is suitable for ISO 5 clean rooms.
GRID
Bioguard
PlaiN
HTM 60 Category
SpecIfIc SOlUtIOnS fOR SpecIfIc AReAS
METAL
■
NEWToNE & CEramaguard
for High Humidity areas
With a true 100% RH resistance, these
products are the ideal solution for swimming
pools, shower areas, toilets and areas subject
to extremes of temperature and humidity.
■
Cleaning
Resistance
to disinfectants
Quaternary Ammonium, Hydrogen Peroxide, Chlorine
* HTM 60 category 1 calls for a smooth, imperforate and jointless soffit. Where access is required Armstrong propose a Clip-In concealed grid ceiling with the joints filled with an
appropriate flexible silicone mastic to provide a ‘jointless’ solution.
** High pressure water cleaning solution is using METAl Clip-In Plain.
Note: For swimming pools and other potentially aggressive environments, there are many variables in the overall design that can impact the suitability of installed materials.
Please contact our Internal Technical Sales for further information.
90
91
BIOGUARD
Specific Solutions > Board & Tiles > BIOGUARD
≤52%
≤87%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content*
bIoGuARD
boARD
Light Reflectance**
TEGuLAR
Prelude Xl2/TlX / CR 24 mm
Clean Room Grid 24 mm
Intelligibility
MIcRoLook
Prelude Xl2/TlX 24 mm
Clean Room Grid 24 mm
Prelude Xl2/Tl 15 mm
Interlude Xl2 15 mm
4.5mm
9.5mm
15/17mm
15/17mm
8mm
M=6.5mm/8mm***
D=7.5mm/8mm***
15°
15/17mm
15°
Bioguard PlaiN
The BIOGUARD paint provides an excellent
anti-microbial performance against various
bacteriological strains. Directly applied to the
smooth plain surface it provides a 87% light
reflectance.
Its ISO 5 Clean Room performance makes
the product suitable for installation in hospital
areas with average or severe risk of infection
or any other Clean Room environment where
anti-microbial performance is required.
Thanks to its enhanced water repellency,
the product can be washed.
BIOGUARD ACOUSTIC provides a
combination of performance solutions for the
healthcare environment.
With its acoustically transparent face scrim,
the product provides a 0.60 aw, meeting
acoustical requirements in hospitals.
BIOGUARD ACOUSTIC Board is available
with fully painted edges to provide the best
guarantee for a clean room environment.
BIOGUARD ACOUSTIC has no pin-holes in
the edges.
600 x 600 x 15 mm
2221 M
2223 M
2224 M
625 x 625 x 15 mm
2221 D
2223 D
2224 D
600 x 1200 x 15 mm
2222 M
625 x 1250 x 15 mm
2222 D
Bioguard aCouSTiC
600 x 600 x 17 mm
2703 M
2551 M
2552 M
625 x 625 x 17 mm
2703 D
2551 D
2552 D
600 x 1200 x 17 mm
2704 M
*** 8mm for BIOGUARD ACOUSTIC
EN ISO 354 &
EN ISO 11654
aw
NRC 125 250 500 1000 2000 4000
• BIOGUARD PlAIN
0.15(L) 0.15 0.30 0.20 0.15 0.10 0.20 0.25
Sound Absorption Class = E
• BIOGUARD ACOUSTIC
0.60(H) 0.60 0.35 0.40 0.50 0.70 0.85 0.90
Sound Absorption Class = C
1.0
Hz
aP
0.8
aP
0.6
0.4
0.2
aP
0
125
250
500
1 000
2 000
4 000
Octave Band centre frequency (Hz)
Dncw 37 dB (BIOGUARD PlAIN)
Dnfw 36 dB (BIOGUARD ACOUSTIC)
EN ISO 10848-2
/ EN 20140-9
& EN ISO 717-1
EN ISO 140-3
& EN ISO 717-1
Rw
19 dB (BIOGUARD PlAIN)
18 dB (BIOGUARD ACOUSTIC)
EEA
healthcare - hospital (Nl),
Bioguard Board
RUS
Euroclass A2-s1, d0
G1, V2, D1, T1 to FZ 123
EN 13501-1
l = 0.06 W/m K
ISO 5
Bioguard PlaiN
EN 12667
& ISO 8301
95 % RH
15 YEAR
guarantee
4.6 kg/m2 (BIOGUARD PlAIN)
3.8 kg/m2 (BIOGUARD ACOUSTIC)
ISO 14644-1
*Recycled Content: 52% BIOGUARD PlAIN - 45% BIOGUARD ACOUSTIC
** light Reflectance: 87% BIOGUARD PlAIN - 85% BIOGUARD ACOUSTIC
Bioguard acoustic
Note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes. Detailed acoustical data are presented on pages 17-19 and our web page.
93
PARAFON HYGIEN (ISO 5)
Specific Solutions > Board & Tiles > PARAFON HYGIEN (ISO 5)
20%
ISO 14021
Recycled Content
PARAFoNHYGIEN
82%
EN ISO
7742-2 & 3
Light Reflectance
Intelligibility
boARD
Prelude Xl2 / TlX / CR 24 mm / Clean Room Grid 24 mm
18mm
600 x 600 x 18 mm
9702 M
625 x 625 x 18 mm
9702 D
600 x 1200 x 18 mm
9703 M
EN ISO 354 &
EN ISO 11654
aw
NRC 125 250 500 1000 2000 4000
0.95
0.95 0.40 0.85 0.90 0.90 0.95 0.90
Sound Absorption Class = A
Hz
aP
1.0
0.8
aP
0.6
0.4
0.2
0
125
This low density product has rock wool
as core material. Its reinforced glass scrim
surface and sealed edges provide an
ISO 5 cleanroom performance and make
the product suitable for high pressure water
cleaning (max 80 bars)*.
Thanks to the acoustically transparent face
scrim and low density base board, the
product achieves a 0.95 aW.
* The application must be in the form of a fan spray
of min 30° angle and not a high pressure “cutting” jet.
The suggested minimum distance between the nozzle
and the ceiling tile should not be less than 300 mm
and the angle of projection should be 45°.
PARAFON HYGIEN should be installed with Trulok
Corrosive Resistant 24 mm grid and be clipped for high
pressure water cleaning.
250
500
1 000
2 000
4 000
Octave Band centre frequency (Hz)
EEA
Euroclass A2-s1, d0
EN 13501-1
l = 0.033 W/m K
EN 12667
& ISO 8301
ISO 5
95 % RH
15 YEAR
1.3 kg/m2
guarantee
ISO 14644-1
healthcare - Kitchen,
ParafoN hygieN
Note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes. Detailed acoustical data are presented on pages 17-19 and our web page.
95
ClEAN ROOM Fl (ISO 5)
Specific Solutions > Board & Tiles > ClEAN ROOM Fl (ISO 5)
*
78%
EN ISO
7742-2 & 3
Light Reflectance
cLEANRooMFL
boARD
Prelude Xl2 / TlX / CR 24 mm / Clean Room Grid 24 mm
15mm
600 x 600 x 15 mm
9527 M
600 x 1200 x 15 mm
9529 M
EN ISO 354 &
EN ISO 11654
aw
NRC 125 250 500 1000 2000 4000
0.10(L)
0.10 0.25 0.15 0.10 0.10 0.10 0.15
Sound Absorption Class = Not classified
Hz
aP
1.0
0.8
aP
0.6
0.4
0.2
0
125
250
500
1 000
2 000
4 000
Octave Band centre frequency (Hz)
Dncw
36 dB
The high density mineral tile is sealed by a
polyester film covering its surface and edges
providing excellent surface strength.
The film doesn’t attract dust and is
particularly adapted to regular washing.
At the ISO 14644-1 test, the international test
method to determine the particle cleanliness
class, the product achieves an ISO 5 class
and is eminently suitable for installation
in computer rooms and in a clean room
environment.
EN 20140-9
& EN 717-1
EEA
RUS
Euroclass A2-s1, d0
GOST 30244-94 ; V1, D1, T1 NPB 244-97
EN 13501-1
l = 0.06 W/m K
EN 12667
& ISO 8301
ISO 5
95 % RH
15 YEAR
5 kg/m2
guarantee
ISO 14644-1
healthcare
cleaN room fl
*Except when installed with silicone joints
Note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes. Detailed acoustical data are presented on pages 17-19 and our web page.
97
CERAMAGUARD (100% RH)
Specific Solutions > Board & Tiles > CERAMAGUARD (100% RH)
≤ 38%
≤ 79%
ISO 14021
EN ISO
7742-2 & 3
Recycled Content
cERAMAGuARD
Light Reflectance
Intelligibility
boARD
Prelude Xl2 / TlX / CR 24 mm / Clean Room Grid 24 mm
15mm
600 x 600 x 15 mm
607 M
600 x 1200 x 15 mm
608 M
EN ISO 354 &
EN ISO 11654
aw
NRC 125 250 500 1000 2000 4000
0.55(MH) 0.60 0.25 0.30 0.50 0.80 0.85 0.75
Sound Absorption Class = D
Hz
aP
1.0
0.8
aP
0.6
0.4
0.2
0
125
CERAMAGUARD is made of a unique high
density ceramic and mineral composite.
This material provides 100% RH resistance
including standing water and is resistant
to chemical fumes.
The product is durable, washable and
scrubbable.
It’s a totally inorganic product, resistant
to growth of mold, mildew and bacteria.
CERAMAGUARD provides good sound
absorption and is ideal for swimming pools,
locker rooms, shower areas and indoor
parking garages.
Note: Cermaguard must be installed on Trulok Corrosive
Resistant 24 mm (CR 24 mm) grid where humidity regularly
exceeds 95% RH.
CERAMAGUARD may need to have main runners at
600 mm centres due to increased weight in high humidity
conditions.
250
500
1 000
2 000
4 000
Octave Band centre frequency (Hz)
Dncw
39 dB
EN 20140-9
& EN 717-1
EEA
RUS
Euroclass A1
NG to FZ 123
EN 13501-1
l = 0.067 W/m K
100 % RH
15 YEAR
guarantee
7 kg/m2
20 kg/m2 if wet
EN 12667
& ISO 8301
leisure - cloakroom,
ceramaguard
Note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes. Detailed acoustical data are presented on pages 17-19 and our web page.
99
NEWTONE (100% RH)
Specific Solutions > Board & Tiles > NEWTONE (100% RH)
84%
EN ISO
7742-2 & 3
Light Reflectance
NEWToNE
Confidentiality
boARD
Prelude Xl2 / TlX 24 mm / CR 24 mm / Clean Room Grid 24 mm
6mm
600 x 600 x 6 mm
EN ISO 354 &
EN ISO 11654
1201 M
aw
NRC 125 250 500 1000 2000 4000
0.10(L)
0.10 0.25 0.15 0.10 0.10 0.10 0.05
Sound Absorption Class = Not classified
1.0
Hz
aP
0.8
aP
0.6
0.4
0.2
0
125
250
500
1 000
2 000
4 000
Octave Band centre frequency (Hz)
Dncw
37 dB
EN 20140-9
& EN 717-1
NEWTONE is a hydrated calcium silicate
ceiling tile particularly suitable for use
in areas subject to extremes of humidity
and temperature.
In addition it is ideal for use in industrial
or semi-exposed locations or where
condensation and resistance to damage
are important considerations.
In all environments where humidity conditions could
regularly reach and/or exceed 90% RH we recommend
the use of our Trulok Corrosion Resistant grids and
associated accessories.
EEA
RUS
Euroclass A2-s1, d0
NG to FZ 123
EN 13501-1
100 % RH
15 YEAR
guarantee
 6 kg/m2
leisure - swimming Pool,
NeWtoNe
Note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes. Detailed acoustical data are presented on pages 17-19 and our web page.
101
standard perForatIon patterns
Standard Perforated
16 % free cross section
Rg 2516 with plain border +/-10 mm
Microperforated
22 % free cross section
Rd 1522 with plain border +/-10 mm
Extra Microperforated
1 % free cross section
Rg 0701 over border perforated
Further perforations are available on request.
Dubai Airport - MetAl Ceilings
METAL CEILINGS
HygIene
colour
METAL Ceiling tiles in any edge detail
or dimension within the Armstrong range,
are available with a BIoGUARD finish.
The METAL BIoGUARD antimicrobial paint
actively reduces colony size and is specifically
designed for areas where enhanced hygiene
performance requirements exist.
For further information, please have a look on
page 91 or contact Internal Technical Sales.
Standard colour
RAL 9010 white (20% gloss), optional Global White (12% gloss)
materIals
Products are made of zinc coated steel.
Gauge of steel used varies as is appropriate
to product type, size and configuration.
RAL 9010
Global White
RAL 9006
RAL 9007
Special colours
other RAL and NCS colours available on request
FInIsH
■ CLIP-IN
■ Hook-oN
■ LAy-IN
■ DESIGN
& CUSToMISED SoLUTIoNS
InstallatIon
FlexIbIlIty
Form
All METAL Ceilings products are designed
for simple and economical installation
on standard exposed systems or purpose
designed grids supplied by ourselves as part
of our service package.
In addition to offering a range of different
module sizes to suit different room scales
and building modules, METAL Ceilings also
offer a range of 1/2 module tiles and part
tiles. If more flexibility of design is required
then Armstrong can offer fully engineered
and custom designed METAL Ceilings for
special projects. For more information about
our capabilities, please contact Internal
Technical Sales.
METAL ceilings offer a full range of plank and
tile metal ceiling options:
• Standard tiles for installation in conventional
grid systems,
• Flexible size plank and tile where modules
must be adapted to the needs of building
layouts and aesthetics,
• Choice of perforation pattern, and also
open Cell with our Cellio offer.
All METAL Ceilings are manufactured to meet
or exceed EN 13964:2004 + A1:2006. Full
details of technical specifications see page
104.
102
Products are finished with a durable,
electrostatic factory applied polyester
powder coat.
securIty
METAL Ceilings products are naturally
strong and impact resistant due to their steel
construction. For additional security,
Axal Vector, Q-Clip, R-Clip, T-Clip F,
R-H 200, R-H 215 and R-H 220 products
can be secured to their supporting grid
structures making them suitable for areas
where preventing unauthorised access
to the ceiling plenum is a requirement.
Q-Clip, R-Clip and R-H 200 products
can also be back coated and secured
for use in semi-external areas.
semI-standard detaIls
The ability to integrate building services
equipment is a major feature of METAL
Ceilings systems. Metal tiles can be
engineered with cut-outs, apertures and
special details to accommodate the
proliferation of services utilised in today’s
modern building projects.
Whether the specifier selects a standard
metal tile or a more customised solution
for his project, lighting fittings, air conditioning
grilles and fire protection equipment need
to be harmonised with the ceiling system.
For us, this is standard practice, and
the advanced manufacturing capabilities
of our METAL Ceilings facilities enable METAL
Ceilings products to be offered complete
with engineered solutions for the
incorporation of building services.
Special size and half module tiles can also
be produced when necessary to finish ceilings
at perimeters and other junctions.
Sprinkler head fitted through circular cut-out
103
TECHNICAL INFoRMATIoN
EN 13501-1
acoustIc perFormance
premIum b15
METAL Ceilings products have been tested for acoustical absorption
and attenuation performance. All perforated products can be supplied
complete with acoustic infill material factory fitted. For most general
open plan areas, non-woven acoustic fleece provides a good level
of absorption performance. The acoustic fleece fitted to METAL
Ceiling tiles is heat bonded to the rear of the tile and optimises flow
resistance characteristics. All perforated items can be delivered with a
black acoustic fleece. Alternative acoustic infills are available, such as
the standard B15 infill and aluminium foil black tissue faced (AFBTF)
acoustic pad which are available upon request. For further information
please contact Internal Technical Sales.
As part of the range of acoustic inlays for METAL Ceilings, Premium
B15 acoustic solutions have been developed to achieve a wide
range of performance values for both sound absorption and sound
attenuation. For example, room to room attenuation of up to Dncw
47dB, and sound absorption of up to aW 0.65. For further information
please contact Internal Technical Sales.
lIgHt reFlectance
Armstrong METAL Ceilings products have been tested
to meet a variety of fire test classifications
Plain without acoustic infill
EEA
Euroclass A1 (RAL 9010)
EEA
Euroclass A2-s1, d0 (other colours)
EEA
Euroclass B-s1, d0 (with gasket)
No acoustic infill
Perforated ø ≤ 2.5 mm
EEA
Euroclass A1 (RAL 9010)
EEA
Euroclass A2-s1, d0 (other colours)
EEA
Euroclass B-s1, d0 (with gasket)
With fleece, aluminium foil black tissue faced (AFBTF)
pad or B15 infill
Perforated ø ≤ 2.5 mm (acoustic fleece)
EEA
Euroclass A2-s2, d0
Perforated ø ≤ 2.5 mm (acoustic fleece and gasket)
EEA
Euroclass B-s2, d0
Perforated ø ≤ 2.5 mm (AFBTF pad)
EEA
Euroclass A1
Perforated ø ≤ 2.5 mm (Premium B15 infill)
EEA
Euroclass A2-s1, d0
Pattern
Plain (unperforated)
Extra Microperforated Rg 0701 with black
acoustic fleece
Perforated Rg 2516 with black
acoustic fleece
Microperforated Rd 1522 with black
acoustic fleece
RAL 9010
85%
Global White
75%
80%
70%
70%
65%
65%
60%
Measured in accordance with EN ISo 7742-2 & EN ISo 7742-3.
tHermal conductIvIty
Pattern
Thermal conductivity W/mK
Plain (unperforated), no inlay
0,244
Plain (unperforated), with fleece
0,163
Plain (unperforated), with 8mm (100 kg/m3)
aluminium foil wrapped mineral wool
0,187
Plain (unperforated), with fleece and B15
0,0731
system IntegratIon
Acoustic fleece black, 63 g/m2
EN ISo 354 &
EN ISo 11654
EN 20140-9
& EN 717-1
104
aw
NRC 125 250 500 1000 2000 4000
• Plain - no infill (EN 2206)
0.10(L) 0.10 0.25 0.15 0.10 0.10 0.10 0.10
• Extra Microperforated Rg 0701 with fleece (EN 2253)
0.55(L) 0.65 0.45 0.75 0.70 0.55 0.55 0.45
Sound Absorption Class = D
• Microperforated Rd 1522 with B15 (EN 2337)
0.60(H) 0.60 0.40 0.40 0.50 0.65 0.75 0.90
Sound Absorption Class = C
• Perforated Rg 2516 with B15 (EN 2340)
0.60(H) 0.60 0.40 0.45 0.50 0.65 0.75 0.90
Sound Absorption Class = C
• Extra Microperforated Rg 0701 with B15 (EN 2334)
0.65
0.60 0.40 0.45 0.55 0.70 0.80 0.70
Sound Absorption Class = C
• Perforated Rg 2516 with fleece (EN L/2463)
0.70(L) 0.70 0.40 0.75 0.65 0.65 0.75 0.75
Sound Absorption Class = C
• Microperforated Rd 1522 with fleece (EN 2175)
0.75
0.80 0.30 0.75 0.90 0.65 0.75 0.80
Sound Absorption Class = C
Dncw
Microperforated Rd 1522 with fleece (EN 2437) = 20 dB
Standard Perforated Rg 2516 with fleece (EN 2437) = 20 dB
Extra Microperforated Rg 0701 with fleece (EN 2432) = 30 dB
Extra Microperforated Rg 0701 with B15 (EN 2427) = 40 dB
Microperforated Rd 1522 with B15 (EN 2443) = 41 dB
Standard Perforated Rg 2516 with B15 (EN 2443) = 41 dB
Plain - no infill (EN 2438) = 44 dB
Plain with B15 (EN 2439) = 47 dB
Premium B15
1.0
Hz
0.8
aP
aP
aP
0.6
0.4
aP
0.2
aP
0
125
aP
250
500
1 000
Octave Band centre frequency (Hz)
2 000
4 000
axal Vector
microLook 8
microLook 16
Tegular 2
Tegular 8
Tegular 11 f
Tegular 16
Board
Q-Clip/Q-Clip f
R-Clip/R-Clip f
S-Clip f
T-Clip f
R-H 200
R-H 215
R-H 220
SILHOUETTE 15
INTERLUDE 15
PRELUDE 15
✔
✔
✔
PRELUDE 24 XL² PRELUDE 24 TLX
GEmaGRID with GEmaGRID with GEmaGRID with GEmaGRID with U-CHaNNEL with
clamping rail
J-BaR
H-PROfILE 35 H-PROfILE 28
SPRING T
DP 12
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
Mutua Madrileña (e)
aP
Rw
aP
EN ISo 140-3
& EN ISo 717-1
Product Name
Microperforation without fleece
Standard perforation without fleece*
Microperforation with fleece
Standard perforation with fleece*
Microperforation with B15
Standard perforation with B15*
PLAIN (no infill)
PLAIN with B15
Weighted value Rw
5
5
6
6
18
18
19
21
* Estimated
1) All Sound Reduction Index (SRI) tests have been conducted in an independent third party quality assured laboratory in accordance with
EN ISo 140-3 with the ceiling suspended horizontally between two
vertical transmission suites.
2) Rw values are determined in accordance with EN ISo 717-1.
3) Values for Standard Perforated (16% open area) are estimated as being
not less than Microperforated (22% open area).
105
CLIP-IN
METAL CLIP-IN > Q-CLIP, R-CLIP
≤ 30%
(1)
Recycled Content
(2)
CLIP-IN
up to
PLaIN
85%
ISO 14021
EN ISO
7742-2 & 3
Light Reflectance
Concentration Confidentiality
Intelligibility
StaNdardPerforated
MICroPerforated
extraMICroPerforated
Rg 2516
Rd 1522
Rg 0701
No perforation
2.5 mm dia. holes
16% open area
1.5 mm dia. holes
22% open area
0.7 mm dia. holes
1% open area
600 x 600 x 35 mm
3809 M
3810 M
3811 M
2094 M
625 x 625 x 35 mm
3809 D
3810 D
3811 D
2094 D
Q-Clip
Q-Clip F
3 mm bevel
500 x 500 x 35 mm
2059 M
2069 M
2078 M
2086 M
300 x 600 x 35 mm*
2058 M
2068 M
2077 M
2085 M
2083 M
600 x 600 x 35 mm
2056 M
2067 M
2076 M
312.5 x 625 x 35 mm*
3805 D
3806 D
3807 D
3808 D
625 x 625 x 35 mm
2056 D
2067 D
2076 D
2083 D
* Without swing down option Window
R-Clip
Choice between:
Q-Clip: square edged
Q-Clip F: 3 mm bevel
R-Clip: square edged
R-Clip F: 3 mm beve
■ Subconstruction GemaGrid with clamping
rail DP 12 (ex System 3000
subconstruction with Spring A Bar)
■ For easy access, all the CLIP-IN products
can be ordered with the swing down option
«Window». See on the page 107.
■
312.5 x 1500 x 40 mm
3812 D
3818 D
3824 D
3830 D
400 x 1500 x 40 mm
3813 M
3819 M
3825 M
3831 M
312.5 x 2000 x 40 mm
3814 D
3820 D
3826 D
3832 D
400 x 2000 x 40 mm
3815 M
3821 M
3827 M
3833 M
312.5 x 2500 x 40 mm
3816 D
3822 D
3828 D
3834 D
400 x 2500 x 40 mm
3817 M
3823 M
3829 M
3835 M
R-Clip F
300 x 1200 x 36 mm
2061 M
2070 M
2079 M
2089 M
600 x 1200 x 36 mm
2062 M
2071 M
2080 M
2087 M
400 x 1800 x 36 mm
2063 M
2072 M
2081 M
2090 M
3 mm bevel
OFFICe - Neores, Schio
Q-Clip
Swing down option «Window»
See page 105
5 kg/m2 – Steel tile
EN 12667
& ISo 8301
(1) For plain tiles or perforated tiles without a fleece
(2) For short term exposure or back painted products (only for items without acoustic inlays).
Note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes. Detailed acoustical data are presented on pages 17-19 and our web page.
107
CLIP-IN
METAL CLIP-IN > S-CLIP F, T-CLIP F
≤ 30%
(1)
Recycled Content
(2)
CLIP-IN
up to
PLaIN
85%
ISO 14021
EN ISO
7742-2 & 3
Light Reflectance
Concentration Confidentiality
Intelligibility
StaNdardPerforated
MICroPerforated
extraMICroPerforated
Rg 2516
Rd 1522
Rg 0701
No perforation
2.5 mm dia. holes
16% open area
1.5 mm dia. holes
22% open area
0.7 mm dia. holes
1% open area
2770 M
S-Clip F
3 mm bevel
600 x 600 x 35 mm
2092 M
2092 M
2093 M
321.5 x 625 x 33 mm
3801 D
3802 D
3803 D
3804 D
625 x 625 x 33 mm
2091 D
2092 D
2093 D
2770 D
300 x 900 x 35 mm
3706 M
3709 M
3712 M
3715 M
300 x 1200 x 35 mm
3707 M
3710 M
3713 M
3716 M
300 x 1500 x 35 mm
3708 M
3711 M
3714 M
3717 M
T-Clip F
5 mm bevel
Choice between:
S-Clip F: 3 mm, bevel swing down.
Subconstruction GemaGrid with clamping
rail DP 12 (ex System 3000 with Spring A
bar).
T-Clip F: 5 mm, bevel. C-channel
with spring-T (ex system 1800 with
spring T bar).
■ Swing down option for easy access
in 3 mm bevel.
500 x 500 x 35 mm
9301 M
9309 M
9428 M
2746 M
300 x 600 x 35 mm
4330 M
4331 M
4332 M
2747 M
600 x 600 x 35 mm
9300 M
9308 M
9337 M
2744 M
675 x 675 x 35 mm
2052 M
2053 M
2054 M
2745 M
750 x 750 x 35 mm
2575 M
2576 M
2577 M
2756 M
300 x 1200 x 35 mm
9304 M
9312 M
9430 M
2748 M
600 x 1200 x 35 mm
4314 M
4315 M
4316 M
2750 M
300 x 1500 x 35 mm
9305 M
9313 M
9431 M
2749 M
See page 105
■
5 kg/m2 – Steel tile
EN 12667
& ISo 8301
(1) For plain tiles or perforated tiles without a fleece
(2) For short term exposure or back painted products (only for items without acoustic inlays)
RetAIl - GGZ Oost Brabant (Nl),
S-Clip F
Note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes. Detailed acoustical data are presented on pages 17-19 and our web page.
109
LAy-IN
METAL LAy-IN > Axal Vector, Board, MicroLook
≤ 30%
(1)
up to
Recycled Content
(2)
LaY-IN
PLaIN
85%
ISO 14021
EN ISO
7742-2 & 3
Light Reflectance
Concentration Confidentiality
Intelligibility
StaNdardPerforated
MICroPerforated
extraMICroPerforated
Rg 2516
Rd 1522
Rg 0701
2.5 mm dia. holes
16% open area
1.5 mm dia. holes
22% open area
0.7 mm dia. holes
1% open area
No perforation
Axal Vector (3) (4)
500 x 500 x 24 mm
3072 M
3075 M
3078 M
3081 M
300 x 600 x 24 mm
2578 M
2579 M
2580 M
2581 M
600 x 600 x 24 mm
9418 M
9419 M
9420 M
2118 M
675 x 675 x 24 mm
3073 M
3076 M
3079 M
3082 M
750 x 750 x 24 mm
3074 M
3077 M
3080 M
3083 M
2771 M
Board (5) (6)
Axal Vector:
■ Can be installed with a very low void depth
■ Clean crisp detailing of 6 mm reveal
■ Easy to install and remove without tools
■ Downwardly accessible
■ Minimal disruption
■ Strongly formed edge resists damage
■ Ideal for renovation and upgrading existing
ceilings installed on Prelude 24 XL2
exposed grid
■ Partially covers old grid
Board, MicroLook:
Fully demountable - easy to replace
■ Board tile is an economical way to obtain
the benefits of a metal ceiling
■ Board to be installed on Prelude 24 TLX
■ MicroLook available with 8 and 16 mm return
■ MicroLook to be installed either on
Prelude 15 XL2/TL, Silhouette or Interlude
(8 mm return only)
■
OFFICe - Fortis Bank (Nl),
Microlook 8 with trulok SIlhOuette grid
600 x 600 x 15 mm
9334 M
9335 M
9427 M
625 x 625 x 15 mm
2119 D
2126 D
2133 D
2771 D
600 x 1200 x 15 mm
2123 M
2125 M
2132 M
2772 M
24mm
MicroLook 8
15mm
500 x 500 x 8 mm
9321 M
9436 M
9325 M
2792 M
600 x 600 x 8 mm
9320 M
9339 M
9324 M
2184 M
675 x 675 x 8 mm
2165 M
2208 M
2210 M
2793 M
750 x 750 x 8 mm
2588 M
2589 M
2590 M
2794 M
300 x 1200 x 8 mm
3718 M
3720 M
3722 M
3724 M
600 x 1200 x 8 mm
3719 M
3721 M
3723 M
3725 M
MicroLook 16
500 x 500 x 16 mm
2190 M
2194 M
2207 M
2788 M
600 x 600 x 16 mm
4700 M
4701 M
4702 M
2787 M
675 x 675 x 16 mm
2144 M
2152 M
2153 M
2791 M
750 x 750 x 16 mm
2585 M
2586 M
2587 M
2789 M
15mm
See page 105
5 kg/m2 – Steel tile
EN 12667
& ISo 8301
(1) For plain tiles or perforated tiles without a fleece.
(2) For short term exposure only (only for items without acoustic inlays).
(3) Use with Prelude 24 XL2 suspension system only.
(4) Axal Vector Rg 2516 & Rd 1522 : 20 mm plain border.
(5) Use with Prelude 24 TLX suspension system only.
(6) Board Rg 2516 & Rd 1522 : over border perforated.
Note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes. Detailed acoustical data are presented on pages 17-19 and our web page.
111
LAy-IN
METAL LAy-IN > Tegular
≤ 30%
(1)
up to
Recycled Content
(2)
LaY-IN
PLaIN
85%
ISO 14021
EN ISO
7742-2 & 3
Light Reflectance
Concentration Confidentiality
Intelligibility
StaNdardPerforated
MICroPerforated
extraMICroPerforated
Rg 2516
Rd 1522
Rg 0701
No perforation
2.5 mm dia. holes
16% open area
1.5 mm dia. holes
22% open area
0.7 mm dia. holes
1% open area
9442 M
9443 M
9444 M
2786 M
Tegular 2 (3)
600 x 600 x 15 mm
24mm
Tegular 8
24mm
500 x 500 x 8 mm
4833 M
4834 M
4835 M
2784 M
600 x 600 x 8 mm
9683 M
9684 M
9685 M
2783 M
675 x 675 x 8 mm
2138 M
2139 M
2140 M
2785 M
300 x 1200 x 8 mm
3726 M
3728 M
3730 M
3732 M
600 x 1200 x 8 mm
3727 M
3729 M
3731 M
3733 M
3839 M
Tegular 11 F
600 x 600 x 11 mm
2147 M
2149 M
2150 M
625 x 625 x 11 mm
2147 D
2149 D
2150 D
3839 D
600 x 1200 x 11 mm
3836 M
3837 M
3838 M
3840 M
24mm
Tegular 16
Tegular:
■ Fully demountable - easy to replace
■ Available with 2, 8, 11 and 16 mm return
■ Tegular 2 version for flush transition with grid
■ Tegular 11 F with 3 mm bevel
■ Tegular to be installed on Prelude 24
■ Tegular 2 to be installed on Prelude 24
TLX grid only.
500 x 500 x 16 mm
4803 M
4804 M
4805 M
2781 M
600 x 600 x 16 mm
9680 M
9681 M
9682 M
2779 M
675 x 675 x 16 mm
2135 M
2136 M
2137 M
2780 M
750 x 750 x 16 mm
2582 M
2583 M
2584 M
2782 M
24mm
See page 105
5 kg/m2 – Steel tile
EN 12667
& ISo 8301
(1) For plain tiles or perforated tiles without a fleece.
(2) For short term exposure or back painted products (only for items without acoustic inlays).
(3) Compatible Prelude 24 TLX only.
OFFICe - leman Office (B), tegular 8
Note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes. Detailed acoustical data are presented on pages 17-19 and our web page.
113
Hook-oN
METAL Hook-oN > R-H 200, R-H 215, R-H 220
≤ 30%
(1)
Recycled Content
(2)
Hook-oN
up to
PLaIN
85%
ISO 14021
EN ISO
7742-2 & 3
Light Reflectance
Concentration Confidentiality
Intelligibility
StaNdardPerforated
MICroPerforated
extraMICroPerforated
Rg 2516
Rd 1522
Rg 0701
2.5 mm dia. holes
16% open area
1.5 mm dia. holes
22% open area
0.7 mm dia. holes
1% open area
No perforation
R-H 200
400 x 1800 x 40 mm
3841 M
3846 M
3851 M
3858 M
400 x 2100 x 40 mm
3842 M
3847 M
3852 M
3859 M
400 x 2400 x 40 mm
3843 M
3848 M
3853 M
3860 M
400 x 2700 x 50 mm
3844 M
3849 M
3854 M
3861 M
400 x 3000 x 50 mm
3845 M
3850 M
3857 M
3862 M
with black gasket 3 mm on short and long side
R-H 215
400 x 1800 x 40 mm
3863 M
3868 M
3873 M
3878 M
400 x 2100 x 40 mm
3864 M
3869 M
3874 M
3879 M
400 x 2400 x 40 mm
3865 M
3870 M
3875 M
3880 M
400 x 2700 x 50 mm
3866 M
3871 M
3876 M
3881 M
400 x 3000 x 50 mm
3867 M
3872 M
3877 M
3882 M
with black gasket 3 mm on short and long side
R-H 220
400 x 1750 x 40 mm
3883 M
3889 M
3896 M
3922 M
400 x 2000 x 40 mm
3884 M
3890 M
3897 M
3923 M
400 x 2250 x 40 mm
3885 M
3891 M
3898 M
3924 M
400 x 2500 x 40 mm
3886 M
3893 M
3899 M
3925 M
400 x 2750 x 50 mm
3887 M
3894 M
3920 M
3926 M
400 x 3000 x 50 mm
3888 M
3895 M
3921 M
3927 M
with black gasket 3 mm on long side. R-H 220 is only for the Swiss market
Rectangular panel systems are especially
suitable for large ceiling areas.
Utilising a concealed suspension system,
Hook-oN has a monolithic appearance.
The individual elements can be easily
disassembled at any time and thus enable easy
access to the ceiling cavity.
See page 105
5 kg/m2 – Steel tile
EN 12667
& ISo 8301
(1) For plain tiles or perforated tiles without a fleece.
(2) For short term exposure or back painted products (only for items without acoustic inlays).
tRANSPORt- tampa Airport (uS),
hOOk-ON
Note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes. Detailed acoustical data are presented on pages 17-19 and our web page.
115
DESIGN & CUSToMISED SoLUTIoNS
Tartan Grid
Tartan grid systems are designed for large rooms
in which a longitudinal and transverse sub-division is
required. Various partition walls can be easily installed
and removed under frames and enable individual
square or rectangular room designs. The grid effect
can be additionally emphasised with appropriate
colouring of the crossing boxes and trim strips.
Decorative accents can be set with pyramid or large
area panels or also emphasised with lights.
Armstrong offer large possibilities of design & customized solutions. Please contact internal Technical Sales for further information.
Corridor Ceilings
Corridor ceiling systems use rectangular panels which are
fixed to the side walls perpendicular to the walking direction.
100 % of the ceiling cavity can thus be used for installations
such as ventilation channels or cables. The individual ceilings
elements can be easily disassembled at any time and thus
ensure optimum access to the ceiling cavity.
Floated Ceilings
Based on a clear modular concept, the D System opens up
a new segment in the ceiling sector. The individual ceiling
canopies meet the highest standards of acoustic qualification,
both for the entire room and also for creation of acoustic
focal points. Lighting of all types can be integrated into the
canopies and thus underline maximum system flexibility.
Vertical Baffles
Vertical baffle systems are the ideal combination of perfect
sound absorption and attractive design. This ceiling
system is particularly suitable for rooms with a high sound
level such as entrance halls, airports, restaurants or
machine rooms. Also with regard to additional functions
such as air conditioning, lighting etc., this aesthetic ceiling
cladding allows almost limitless design possibilities.
CeLLio Ceilings
CELLIo, Armstrong’s open cell metal ceiling, is suitable for
all types of areas and is available in a number of cell sizes.
The monolithic appearance of CELLIo is achieved by the
integration of the grid into the ceiling design.
This concept allows for unlimited design scope and flexible
functional benefits. Detailing at the junction of wall and ceiling
is a good example of this flexibility.
CELLIo is particularly ideal for refurbishing projects where
a 15 mm exposed grid is already in place or in large areas
where a perfect cell alignment is required.
Linear Grid
Linear-grid systems, used especially in office complexes,
are designed for large rooms with flexible partitioning. Partition
walls can be easily positioned and moved within the grids.
Visible support profiles set striking accents, a line is visually
emphasised. Rectangular panels combined with different
lighting make extremely cost-effective, efficient lighting
possible and also offer many possibilities of visual
and functional interior design.
116
Wall Claddings
The main advantages of the wall cladding systems
are the variety of designs and applications and the
simple assembly and disassembly. The system range is
characterised by their simple planning, versatile uses and
impressive appearance in any shape of room.
Areas of application: as acoustic elements and
architectural design elements.
117
Description
GriD coorDination
Wood: the most beautiful, natural element you can find in the world
for interior decoration, is available from Armstrong. Wood will enable
you to create the most original and warm interiors. Whether plain or
perforated, paper laminate or wood veneer, you can select the precise
texture and colour best suited to your project
Wood will become your favoured choice for exclusive projects
including conference rooms, lobbies, offices, department stores,
restaurants, speciality shops, waiting and music rooms.
Armstrong wood tiles are 600 x 600 mm in MicroLook, SL2 and Vector
edge details. They are made with a medium density fibreboard (MDF)
or chipboard base material with either a natural wood veneer or printed
laminate surface. The surface is plain or perforated with an acoustical
black tissue fleece on the back.
Conditions of installation
Wood tiles should be unpacked and stocked flat in an environment
that is closed and not humid. Wood tiles should always be moved
with care. Before installation, it is recommended to open the cartons
and stack the tiles flat for 3 to 8 days in the room where they will
be installed in order to stabilise the tiles in their future environment
and conditions of use. Possible dimensional variations in a humid
environment are those from typical wood-based tiles i.e. the differential
between the driest and the most humid conditions can be up to
5 mm/m. The installation of Wood tiles should take place during
the last phase of the job, in closed, and sometimes heated, rooms.
No additional work potentially increasing the level of humidity in the
room should be undertaken after the tiles are installed (concrete and
plasterboards should be dry). Wood tiles should never be installed
in rooms whose relative humidity is greater than 80% at 20°C.
The optimum installation conditions are reached when the room
temperature is between 12 and 24°C for a relative humidity between
45 and 70%. In rooms where relative humidity is kept below 45%
or above 70%, additional care should be given for installation.
■
■
■
■
MicroLook: For better coordination between grid and tile the use
of Prelude 15 mm in black, rAL 9006 and brown is recommended.
For a special accent on design, Interlude may also be considered.
The elegant visual of Silhouette in black is an excellent option,
providing an aesthetically enhanced support grid with specific
benefits where partition head locating positions are required.
SL2: The MADerA SL2 ceiling range provides a monolithic visual
by hiding the grid system and is available in the same finishes as
MicroLook.
Vector: The Vector edge detail works with a traditional 24mm
exposed grid, the tiles cover a large part of the grid creating an
elegant 6mm reveal to each tile which gives a monolithic appearance
to the ceiling.
acoustical performance
For improved acoustical performance, 5 perforation options are
available. Alternative finishes and perforations are available on request.
Further enhancements in speech and listening conditions can be
attained by mixing Wood tiles with performance mineral tiles such as
COLOrTONe DUNe and NeeVA
Installation recommendations
MADerA Veneer ceiling tiles are made with natural wood veneers.
As they are natural products, their colour and structure regularity
cannot be guaranteed. In order to obtain the best decorative effect,
we advise you to follow the points below:
1. Display all the tiles before fitting.
2. Arrange them aesthetically with regard to their shade and grain.
3. Install the ceiling tiles accordingly.
With each order, it is recommended to allow for some extra tiles
to accommodate for visual variations, as it will be very unlikely
that similar looking tiles can be ordered later.
■
WOOD
Additional capabilities
If required on a job site, cutouts can be factory made upon special
request. Additionally, other veneers and laminates are available
on a special order basis.
■
■ MADerA
Please contact ATS or visit our website for updated information on the WOOD range.
LEISURE - LaSko HotEL & Spa (SLo)
118
119
MADerA
Wood > Board & Tiles > MADerA
lAMiNAtEs
MADERA
wooDvENEERs
Curly Maple (CM)
Pear (PH)
Lime Tree (LM)
US Cherry (UC)
US Maple (UM)
Beech (BH)
MicRolook
vEctoR
Interlude, Silhouette: white, black
or white/black
Prelude 15: white, black,
rAL9006 or brown
Prelude XL2 24 mm
Prelude Sixty2
4.95mm
8mm
12/13mm
20
32
594
584
20
22
594
584
72 150
22
20
20
A1
(4.6% open area)
587mm
575mm
6mm
12/13mm
3.5/4.5mm 3.5/4.5mm
594mm
10mm 10mm
12/13mm
5.5/6.5mm
16/17mm
600mm
594mm
12mm
12mm
16mm
Plain
600 x 600 x 12/16 mm
9774 M
2558 M
9936 M
Perforation A1 (ø 8mm)
600 x 600 x 12/16 mm
9776 M
2559 M
9938 M
Perforation A2 (ø 6mm)
600 x 600 x 12/16 mm
9775 M
2560 M
9937 M
67
Perforation A8
600 x 600 x 12/16 mm
9924 M
2561 M
9939 M
160
160
Perforation A10
600 x 600 x 12/16 mm
9925 M
2562 M
9940 M
Perforation A12
600 x 600 x 12/16 mm
9927 M
2564 M
9942 M
130
160
160
72
67
67
67 150
150 72
72 150
72
150 67
67
130
584 594
Prelude 24 mm
Main runner
Prelude Sixty2
Laminates: available CM, LM, PH
150 72
22
10°
12/13mm
10°
PERFoRAtioNPAttERNs
6mm
575mm
10°
sl2
584 594
A2
(0.8% open area)
22
A8
A10
A12
(5.3% open area)
(6.3% open area)
(9.5% open area)
Wood Veneers: available BH, UC, UM
13mm
13mm
17mm
Plain
600 x 600 x 13/17 mm
9777 M
2566 M
9945 M
Perforation A1 (ø 8 mm) 600 x 600 x 13/17 mm
9779 M
2567 M
9947 M
Perforation A2 (ø 6 mm) 600 x 600 x 13/17 mm
9778 M
2568 M
9946 M
Perforation A8
600 x 600 x 13/17 mm
9930 M
2569 M
9948 M
Perforation A10
600 x 600 x 13/17 mm
9931 M
2570 M
9949 M
Perforation A12
600 x 600 x 13/17 mm
9933 M
2572 M
9951 M
iNstAllAtioNsl2
Wood Veneers
Laminates
Spacer Bar
BP CA5733A
eN ISO 354 &
eN ISO 11654
Prelude 24 Peakform
main runner
Curly Maple
 75%
US Cherry
 25%
Pear
 35%
Beech
 40%
Lime Tree
 55%
US Maple
 60%
aw
NrC 125 250 500 1000
• MADerA A1
0.45(L)
0.45 0.40 0.60 0.55 0.45
• MADerA A2
0.20(L)
0.20 0.35 0.30 0.20 0.15
• MADerA A8
0.35(L)
0.45 0.40 0.60 0.55 0.40
• MADerA A10
0.35(LM) 0.50 0.45 0.60 0.60 0.40
• MADerA A12
0.50(L)
0.60 0.45 0.70 0.70 0.55
SoundAbsorptionClass=uptoClassD
eeA
1500 mm max.
2000 4000
Hz
0.35 0.35
aP
0.15 0.15 aP
1.0
0.8
aP
0.6
0.4
0.2
0
0.30 0.20 aP
125
250
500
1 000
2 000
4 000
Octave Band centre frequency (Hz)
0.30 0.25
aP
0.45 0.30
aP
euroclass B-s2, d0
eN 13501-1
l = 0.12 W/m K
600 mm
70 % rH
Laminates  10 kg/m2
Wood Veneers  10.5 kg/m2
eN 12667
& ISO 8301
120
Note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes. Detailed acoustical data are presented on pages 17-19 and our web page.
121
product innovation
■
Prelude univerSal main runner
The Prelude universal Main Runner supports the installation of either hook/butt cut or stab/joggled Cross Tees from one simple inventory
of Main Runners. The universal system is available in Peakform design in both 24 mm and 15 mm widths. The Peakform Universal Main
Runners with Superlock clip provide a quick and easy assembled Main Runner to Main Runner/ bulb-to-bulb connection. Metric sized Main
Runners are slotted at 100 mm centres for more flexibility. Slots are machined to receive positive and accurate assembly of either Prelude
TL, Prelude TLX (hook installation) or Prelude XL2 (stab installation) Cross Tees. The staked-on Superlock clip allows for Main Runners to be
disconnected and reconnected laterally in low-clearance areas or in the middle of a room.
SUSPENSION SYSTEMS
■ Designer
grid > AXIOM Profiles & Transitions, INTERLUDE, SILhOUETTE
■ Exposed
grid > PRELUDE 15, 24, 35, SIXTY², BANDRASTER
■ Concealed
■ Specific
PRELUDE TL
grid > System Z
application > Clean Room Grid, Corrosive Resistant
PRELUDE XL2
PRELUDE TLX
armstrong philosophy & service
■ TOTal CeilinG SOluTiOnS
The Trulok suspension system product range
forms an integral part of Armstrong’s total
ceiling solutions policy. Armstrong now offers
its customers and specifiers a complete range
of ceiling panels including mineral, soft fibre,
wood and metal and a wider choice than
ever of suspension systems. Armstrong can
provide solutions for all elements in today’s
challenging construction environments.
QualiTY
Trulok suspension systems are manufactured
for Armstrong both by its joint venture
company WAVE (Worthington Armstrong
Venture) and through various alliances
with other companies who are regarded
as specialists in their fields of engineering.
WAVE operates on a global basis, and brings
to its various European operations world
class practice on the most technologically
advanced equipment.
■
ServiCe
Trulok suspension systems are manufactured
in three European plants, strategically
located to serve all our European customers.
Additionally, both Armstrong and WAVE
can draw upon their global manufacturing
capabilities for both specialiaty products and
manufacturing support.
In addition to WAVE’s manufacturing sites,
Armstrong stocks suspension systems in
distribution centres throughout Europe.
This allows our customers the convenience
of mixed product shipments, combining
suspension systems with other Armstrong
ceiling products, optimising bulk shipments
direct from their manufacturing locations.
■
prelude xl2
prelude tl
prelude tlx
“stab” installation
“hook” installation
“hook” installation
Prelude XL2 Cross Tees in both 24 mm and
15 mm widths feature an advance stab
system that locates with an audible “click”,
ensuring a solid installation at all times.
The stab end is precision stamped from
a separate piece of high grade steel
permitting an increased accuracy and
economy of production over the more
conventional integral forming of the Cross Tee
ends. The Cross Tees are inserted to the right
of each other through the Main Runner slots
and easily pushed home.
Prelude TL Cross Tees in 15 mm widths
feature an integrally formed hook nose.
This popular installation system has been
a feature of Armstrong Trulok suspension
systems for over 20 years and its proven
ease of assembly and precise butt cut joint
has been a favourite of installers. Cross Tee
alignment is ensured by locating the Cross
Tee to the right hand side of the adjoining
section.
The patented TLX clip is a new highly
engineered staked-on hook detail designed for
24 mm cross tees.
Its unique steel-based composite material
and shape provide a stronger and level
connection, an improved fire performance
and an increased overall stability.
TLX Cross Tees are quicker and easier to cut
due to the Peakform section. When the TLX
Cross Tees are inserted to the right of each
other through the Main Runner slots, the TLX
clip provides a more secure installation.
the trulok range
The Trulok range includes a full range of solutions for all ceiling suspension requirements:
. General applications, a range of standard Prelude 24 mm and Prelude 15 mm grid systems, Bandraster and Prelude Sixty2 for longer spans.
Drywall Grid Systems are available for plasterboard ceilings.
. designer options including the minimalist grid Silhouette, Interlude and the Axiom range.
. Specific applications, for clean room and higher humidity environments (Corrosive Resistant Grid or Clean Room Grid).
. Perimeter trims and accessories, for most applications.
. Seismic accessory range, for seismic areas
We also include our comprehensive programme of special size options that is available in most ranges. A range of either stab or hook systems are
available to meet the mechanical preferences of the installer. To complete the portfolio we also offer a technical test programme that provides fire
and loading performance and environmental accreditation. Trulok suspension systems are designed for use with a wide variety of Armstrong ceiling
products, mineral, soft, metal, wood and our special solutions.
The Trulok range is covered by intense fire reaction and fire resistance programs to meet all the European standards ( like EN 13964 ).
environment
Armstrong’s suspension systems contain up
to 25% of recycled content. Up to 100% of
the packaging is made from recycled
material. Moreover, Armstrong pays attention
to the quality of all its products to enhance
their durability, maintenance and longevity.
colour
Trulok suspension system components are
manufactured in a range of colours and metal
finishes including Global White to complement
Armstrong ceiling tiles. A further 180 RAL
colours are available upon request as a
special order. For complete information call
Internal Technical Sales.
peakform
Peakform profiles are engineered to
create a stronger, more stable suspension
system making installation both faster
and easier.
All the grid shown next to the Peakform
icon is provided with such an improved bulb
shape.
Please, discover our TrulOK mainline brochure on our website.
122
note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes.
123
Designer grid >
AXIOM PROFILES
Designer grid >
Available in 5 heights with a plasterboard trim section, Axiom Profiles are
compatible with Trulok 24 mm and 15 mm grid systems including designer grid.
■ axiOm PrOfileS
The 5 sections are designed to provide a flush transition between plaster margin and mineral,
metal or wooden suspended ceilings, and a shadow gap detail between the plasterboard margin and the wall.
19
Item Nr.
Description
BP 52 42 06 G(1)
BP 54 42 06 G(1)
BP 56 42 06 G(1)
BP 58 42 06 G(1)
BP 55 14 11 G(1)
Axiom Profiles 50 mm
Axiom Profiles 100 mm
Axiom Profiles 150 mm
Axiom Profiles 200 mm
Axiom Vector Profiles 112 mm
19
Dimensions
length (mm) height (mm)
Item Nr.
Description
BPT 3215 G(1)
Axiom Transitions angle
3000
50
BPT 3208 G(1)
Axiom Transitions for
Tegular/MicroLook
3000
50
50
BPT 3219 G(1)
Axiom Transitions channel
3000
50
50
BPT 3210 G(1)
Axiom Transitions for Vector
3000
50
BPT 3225 G(1)
Axiom Transitions plasterboard
3000
50
■ axiOm TranSiTiOnS
112
200
100
50
100
150
200
112
15
25
15
15
50
8
25
18.5
BPT 3213 H(1)
AXIOM Profile plasterboard trim
3000
15
18,5 x 25,5
25.5
15
25
■ aCCeSSOrieS fOr axiOm PrOfileS
Item Nr.
BPa 344 G
BPa
BPa
BPa
BPa
BPa
334
335
336
337
345
G
G
G
G
G
Description
BPA 334 G
BPA 335 G(1)
BPA 336 G(1)
BPA 337 G(1)
BPA 345 G(1)
(1)
BPa 340 G
Axiom Profiles corner post 50 mm
Axiom Profiles corner post 100 mm
Axiom Profiles corner post 150 mm
Axiom Profiles corner post 200 mm
Axiom Vector corner post 112 mm
15
19
Dimensions
height (mm)
11
50
100
150
200
112
25
15
35
perimeter trim
15
25
BPa 338 G
15
■ aCCeSSOrieS fOr axiOm TranSiTiOnS
BPa 344 G
Item Nr.
Description
BPA 321 G
Axiom Transitions
suspension clip – straight
79
Axiom Transitions
suspension clip – angled
62
BPa 321 G
BPa 339 H
BPa 322 G
79
■ aCCeSSOrieS fOr axiOm PrOfileS and TranSiTiOnS
(1) Available in White RAL 9010.
124
Dimensions
length (mm)
height (mm)
50
3000
3000
3000
3000
3000
50
19
150
19
AXIOM TRANSITIONS
BPA 340 G
Axiom universal corner clip
BPA 338 G
Axiom universal splice plate
BPA 339 H
Axiom universal T-bar connector clip
BPA 344 G
Axiom universal hanging clip
BPA 322 G
BPa 340 G
62
BPa 339 H
BPa 338 G
Dimensions
height (mm)
(1) Available in White RAL 9010.
Note: As Axiom is an aluminium extrusion it should not be used in ceiling assemblies where
structural fire protection is required. All measurements in millimetres. All sizes are nominal.
note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes.
125
Designer grid >
INTERLUDE 15 XL2
Designer grid >
Exposed 15 mm grid system (nominal). Interlude XL2 is a suspension system developed
for creative ceiling solutions, and quick and easy installation.
SILhOUETTE 15 XL2
Exposed 15 mm grid system (nominal). Silhouette XL2 is a suspension system designed
to create a crisp, clean look in conjunction with MicroLook tiles to provide an enhanced aesthetic.
Available with either a 6 mm or 3 mm reveal.
Silhouette Cross Tee with 3 mm reveal
Peakform
xl2 Clip
Silhouette
main runner
with 3 mm
White reveal
double Stiching
Silhouette
main runner
with 6 mm
Black reveal
interlude
main runner
with 5 mm reveal
■ main runner inTerlude 15 (by-pass connection)
■ main runner SilHOueTTe 15 (by-pass connection)
Item Nr.
44mm
BP 61 40 42 G
Item Nr.
Dimensions
length (mm)
height (mm)
3600
44
44mm
6mm
5mm
44mm
height (mm)
with 6mm reveal
BP 80 40 42 G
BP 80 48 42 G
BP 80 39 43 G
BP 80 44 42 G
3600
3500
3125
2700
44
44
44
44
with 3mm reveal(2)
BP 81 40 42 WR G
3600
44
1200
1250
1350
1000
44
44
44
44
600
625
675
500
300
44
44
44
44
44
1200
600
44
44
(1)
3mm
■ CrOSS TeeS inTerlude 15 xl (stab system)
2
44mm
Dimensions
length (mm)
Cross Tees slotted
BP 61 30 42 G
■ PeaKfOrm CrOSS TeeS SilHOueTTe 15 xl2 (stab system)
1200
44
5mm
44mm
6mm
Cross Tees unslotted
BP 61 20 42 G
600
44
BP 61 24 42 G
300
44
with 6mm reveal(1)
BP 80 30 42 G
BP 80 31 43 G
BP 80 33 42 G
BP 80 32 42 G
BP 80 20 42 G
BP 80 21 43 G
BP 80 23 42 G
BP 80 22 42 G
BP 80 24 42 G
44mm
with 3mm reveal(2)
BP 81 30 42 WR G
BP 81 20 42 WR G
3mm
(1) Available in white, black (BK) or white with black reveal (BI). (2) WR = White RAL 9010
126
note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes.
127
Exposed system >
PRELUDE 15
Exposed system >
Exposed suspension system 15 mm (nominal).
PRELUDE 24
Exposed suspension system 24 mm (nominal).
Cross Tee 24 Tlx
Cross Tee 15 Tl
universal main runner 15
Peakform with Superlock clip
universal main runner 24
Peakform with Superlock clip
Cross Tee 24 xl2
Peakform
Cross Tee 15 xl2
Peakform
■ univerSal main runner 24 PeaKfOrm and SuPerlOCK CliP (bulb-to-bulb connection)
■ univerSal main runner 15 PeaKfOrm and SuPerlOCK CliP (bulb-to-bulb connection)
Item Nr.
Item Nr.
length (mm)
43mm
15mm
Dimensions
BP 30 40 33 A(1)
BP 30 41 33 A(1)
BP 30 43 33 A
3600
3750
3375
43mm
height (mm)
43
43
43
24mm
■ CrOSS TeeS Prelude 24 Tlx
(hook system, butt cut)
■ PeaKfOrm CrOSS TeeS Prelude 15 xl2 (stab system, override)
38mm
15mm
Cross Tees slotted
BP 30 30 33 B(1)
BP 30 31 33 A
BP 30 32 33(2)
Cross Tees unslotted
BP 30 20 33 B(1)
BP 30 21 33 A
BP 30 22 33(2)
38mm
1200
1250
1000
600
625
500
38
38
38
38
38
38
■ CrOSS TeeS Prelude 15 Tl (hook system, butt cut)
38mm
15mm
38mm
24mm
■ CrOSS TeeS Prelude 24 xl2 (stab system, override)
Cross Tees slotted
BP 10 34 33 B
BP 10 36 33 A
BP 10 33 33
BP 10 31 33 B(1)
BP 10 30 33 A(1)
Cross Tees unslotted
BP 10 23 33
BP 10 21 33 B(1)
BP 10 20 33 A(1)
BP 10 25 33
BP 10 24 33 A
1800
1500
1350
1250
1200
38
38
38
38
38
675
625
600
312,50
300
38
38
38
38
38
Please contact your Armstrong office for more information. All sizes are nominal.
(1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE) and White RAL 9010 (WR). (2) Also available in RAL 9010 (WR).
128
24mm
38mm
24mm
35/38mm
24mm
30mm
24mm
length (mm)
Dimensions
height (mm)
BP 31 40 32 A(1)
BP 31 41 33 B(1)
BP 31 43 33 B
BP 31 42 32
BP 31 09 42
3600
3750
3375
3000
2400
43
43
43
43
43
Cross Tees slotted
BP 13 31 31(1)
BP 13 30 31(1) (2)
BP 13 60 31
1250
1200
600
38
38
38
BP 13 10 32
BP 13 34 32
BP 13 50 32
BP 13 36 32
BP 13 33 31
BP 13 32 32
1875
1800
1724
1500
1350
1000
38
38
38
38
38
38
Cross Tees unslotted
BP 13 18 31
BP 13 16 31
BP 13 21 31(1)
BP 13 20 31(1) (2)
900
750
625
600
38
38
38
38
BP 13 23 31
BP 13 22 32
675
500
38
38
Cross Tees slotted
BP 31 33 31
BP 31 31 51 B(1)
BP 31 30 51 B(1)
BP 31 32 31(3)
1350
1250
1200
1000
38
38
38
38
BP 31 34 31 A
1800
38
Cross Tees unslotted
BP 31 16 32
BP 31 25 51 G
BP 31 24 51 G
BP 31 23 21
BP 31 21 23 A(1)
BP 31 20 21 A(1)
BP 31 22 21(3)
750
312,5
300
675
625
600
500
38
35
35
30
30
30
30
Please contact your Armstrong office for more information. All sizes are nominal. (1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE) and White RAL
9010 (WR). (2) Also available in Black (NG), Brown (MR) and Beige (BJ). (3) Also available in RAL 9010 (WR).
note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes.
129
Exposed system >
PRELUDE SIXTY²
Exposed system >
Exposed 24 mm grid system.
Double Peakform Main Runner section requiring less suspension points
and compatible with Prelude 24 XL2 and TLX Cross Tees.
PRELUDE 35
Exposed Suspension System 35 mm (nominal):
the Prelude 35 grid is available with white and galvanised capping as well
as in a knurled version recommended for dry wall assemblies.
double Peakform bulb:
a stronger section for an easier installation
doubled stitched
for improved torsional strength
Prelude 24 TLX
Cross Tees
Prelude 24 XL2
Cross Tees
Superlock clip
compatible with the Prelude 24
Peakform Universal Main Runner
■ univerSal main Prelude SixTY2 dOuBle PeaKfOrm WiTH SuPerlOCK CliP (bulb to bulb connection)
Item Nr.
■ main runner Prelude 35 (bulb-to-bulb connection)
Dimensions
length (mm)
Item Nr.
height (mm)
BP 40 40 93 G(1)
BP 40 41 93 G(1)
BP 40 43 93 G(1)
24mm
3600
3750
3375
62
62
62
38mm
35mm
■ CrOSS TeeS Prelude 24 Tlx
(hook system, butt cut)
38mm
24mm
38mm
24mm
Cross Tees slotted
BP 13 31 31(1)
BP 13 30 31(1) (2)
BP 13 60 31
1250
1200
600
38
38
38
BP 13 10 32
BP 13 34 32
BP 13 50 32
BP 13 36 32
BP 13 33 31
BP 13 32 32
1875
1800
1724
1500
1350
1000
38
38
38
38
38
38
Cross Tees unslotted
BP 13 18 31
BP 13 16 31
BP 13 21 31(1)
BP 13 20 31(1) (2)
900
750
625
600
38
38
38
38
BP 13 23 31
BP 13 22 32
675
500
38
38
38mm
24mm
35/38mm
24mm
30mm
24mm
Cross Tees slotted
BP 31 33 31
BP 31 31 51 B(1)
BP 31 30 51 B(1)
BP 31 32 31(3)
1350
1250
1200
1000
38
38
38
38
BP 31 34 31 A
1800
38
Cross Tees unslotted
BP 31 16 32
BP 31 25 51 G
BP 31 24 51 G
BP 31 23 21
BP 31 21 23 A(1)
BP 31 20 21 A(1)
BP 31 22 21(3)
750
312,5
300
675
625
600
500
38
35
35
30
30
30
30
(1) Colours available: Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE) and White RAL 9010 (WR). (2) Also available in Black (NG), Brown (MR) and Beige (BJ).
(3) Also available in RAL 9010 (WR). All measurements in millimetres. All sizes are nominal.
130
height (mm)
White capping
BP 12 40 33 A
BP 12 45 33 A
3600
3520
38
38
Galvanised capping
BP 12 40 33 UP
BP 12 45 33 UP
3600
3520
38
38
Knurled - plasterboard option
BP 12 40 33 KD
BP 12 45 33 KD
3600
3520
38
38
White capping
BP 12 36 33 A
BP 12 30 33 A
1500
1200
38
38
Galvanised capping
BP 12 36 33 UP
BP 12 30 33 UP
1500
1200
38
38
Knurled - plasterboard option
BP 12 36 33 KD
BP 12 30 33 KD
1500
1200
38
38
■ Prelude 35 CrOSS TeeS (hook system, override)
38mm
■ CrOSS TeeS Prelude 24 xl2 (stab system, override)
Dimensions
length (mm)
62mm
35mm
Please contact your Armstrong office for more information. All sizes are nominal.
note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes.
131
Exposed grid >
BANDRASTER SYSTEM
Concealed grid >
Bandraster is a suspension system available
in a wide range of widths, compatible with Prelude 24 TLX/XL2 Cross Tees.
■ BandraSTer SeCTiOnS
36mm
12mm
150 / 125 / 100 / 75 / 50mm
Item Nr.
Slotted
at 312.50 mm
BP 36 21 00 B
Slotted
at 100 mm
BP 36 30 50
BP 36 30 75
BP 36 31 00(1)
BP 36 31 25
BP 36 31 50
Unslotted
BP 36 00 50 A
BP 36 00 75 A(1)
BP 36 01 00 A
BP 36 01 25 A
BP 36 01 50
(1) Also available in RAL 9010 (WR)
132
Semi-concealed and concealed systems.
Provides dedicated solution for corridors giving a monolithic visual. Can also be
used for room situations in conjunction with Prelude 24 and Bandraster grid.
■ Semi-COnCealed - COmPaTiBle WiTH Sl2
■ BandraSTer aCCeSSOrieS
Dimensions
length (mm) width (mm)
3750
3600
3600
3600
3600
3600
3600
3600
3600
3600
3600
100
50
75
100
125
150
50
75
100
125
150
SYSTEM Z
Item Nr.
BPA 36 05 01
BPA 36 07 51
BPA 36 10 01
Description
Dimension
width (mm)
Strip / rod connector
50
75
100
BPA 36 05 02 G Nonius hanger
BPA 36 07 52 G
BPA 36 10 02 G
BPA 36 12 52 G
BPA 36 15 02 G
50
75
100
125
150
BPA 36 05 03 G Splice
BPA 36 07 53 G
BPA 36 10 03 G
BPA 36 12 53 G
BPA 36 15 03 G
50
75
100
125
150
BPA 36 05 04 G Cross connector
BPA 36 07 54 G
BPA 36 10 04 G
BPA 36 12 54 G
BPA 36 15 04 G
50
75
100
125
150
BPA 36 05 05 G Wall connector
BPA 36 07 55 G
BPA 36 10 05 G
BPA 36 12 55 G
BPA 36 15 05 G
50
75
100
125
150
BPA 36 05 06 G Crossing element
BPA 36 07 56 G
BPA 36 10 06 G
50
75
100
Item Nr.
Description
BP CZ 41494 H
BP CZ 41794 H
BP CZ 41795 H
Deep Z 32 mm
Deep Z 32 mm
Deep Z 70 mm
1500
1800
2500
BP CA5740 G
Double height Z
4000
BP CA 5733 A
BP CA 5734
Spacer bar
Spacer bar
19
32/70
19
Dimensions
height (mm)
35
55
19
600/625
1200/1250
Other lengths can be produced as special between 300 and 2500 mm
Please contact your Armstrong office for more information. All sizes are nominal.
note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes.
133
SPECIFIC APPLICATION
SUSPENSION INTEGRATION
CORROSIVE RESISTANT GRID
CLEAN ROOM GRID
■ variOuS SuSPenSiOn HanGerS
Exposed 24 mm grid system (nominal). Special paint finish
and TLX steel-based composite clip for enhanced corrosion
resistance. Corrosion resistance 700 hours salt spray test on
grids according to EN ISO 9227 standards.
Exposed 24 mm grid system (nominal). A complete system
solution: Aluminium construction for maximum corrosion
resistance and non-magnetic environments. Co-extruded with
a unique factory applied gasket for a better seal between tile
and grid. System suitable for use in applications up to Class 4
performance as per Class ISO standard 14644-1.
■ univerSal main runnerS 24 COrrOSive
reSiSTanT PeaKfOrm and SuPerlOCK CliP
(bulb to bulb connection)
■ main runner Clean rOOm Grid SYSTem 24
Item Nr.
Item Nr.
Dimensions
length (mm) height (mm)
BP 28 40 42
BP 28 41 42
3600
3750
43
43
■ a larGe CHOiCe Of aCCeSSOrieS
■ a larGe ranGe Of PerimeTer TrimS
Dimensions
length (mm) height (mm)
6
8
BPEA 794044
43mm
3600
43
24mm
43mm
■ CrOSS TeeS Clean rOOm Grid SYSTem 24
24mm
■ PeaKfOrm CrOSS TeeS Tlx 24 COrrOSive
reSiSTanT (hook system, butt cut)
Item Nr.
6
8
43mm
Item Nr.
38mm
24mm
Dimensions
length (mm) height (mm)
BP 14 30 32
BP 14 31 32
BP 14 20 32
BP 14 21 32
1200
1250
600
625
38
38
38
38
24mm
Dimensions
length (mm) height (mm)
BPEA 793044
1200
43
BPEA 792044
600
43
■ aCCeSSOrieS
BPA WDNCR 20 H
Bent tee bar hanger
for threaded rod
BPA CR1827 G
Nut for threaded
rod
BP CHDC
Hold down clip
suitable for
non-magnetic areas
BPA 426
Board access clip
18
12
BPA CR1829 G
Threaded rod dia.
6 mm
38
BPA CR7890 G
Universal retaining
clip
55
55
125
BPA CR827 G
1700 mm
hanger with hook
BPA CR11 G
Small hook
BPA CR12 G
Butterfly clip
55
■ PerimeTer Trim
24
24
BPT 1924 LB
Corrosive resistant
suspension angle
24
INTERLUDE 15
PRELUDE 15
PRELUDE 24 XL² PRELUDE 24 TLX PRELUDE SIXTy²
PRELUDE 35
BANDRASTER
SySTEM Z
Vector
✔
MicroLook
✔
MicroLook BE
✔
Tegular
✔
✔
✔
✔
✔
✔
✔
Board
✔
✔
✔
✔
SL2/K2C2
✔
✔
✔
✔
METAL Axal Vector
✔
✔
METAL MicroLook 8
✔
✔
✔
✔
✔
✔
✔
✔
✔
Metal
Item Nr.
1700
SILHOUETTE
3 & 6 mm
Mineral
19
57
The chart below presents the Trulok grid systems with their related ceiling product families.
AXIOM
(Transitions/Profiles)
■ aCCeSSOrieS - COrrOSiOn reSiSTanCe
700 HOurS SalT SPraY TeST
19
■ SYSTem inTeGraTiOn
BPEA 7801
Dimensions
length (mm) height (mm)
3660
24
METAL MicroLook 16
✔
✔
✔
✔
✔
METAL Tegular 2
✔
✔
✔
METAL Tegular
8, 11F or 16
✔
✔
✔
✔
✔
METAL Board
✔
✔
✔
19
Please contact your Armstrong office for more information. All sizes are nominal.
134
note: Product availability may vary. Please contact ATS or visit our website for updated information or other sizes.
135
INSTALLATION & MAINTENANCE
INSTALLATION & MAINTENANCE
Safety
Storage
Installation
The material must be stored flat and isolated
from the ground in a location which is not
subject to excessive humidity or precipitation.
Follow the 5 successive steps and illustrations
(eg for a 600 x 600 mm exposed grid ceiling):
Armstrongs commitment on safety concerns
each and every step of our business:
. in our plants & offices, we have implemented
rigorous safety policies and procedures
to help minimise risk
. for our products, for which we ensure
compliance with appropriate European
and local safety regulations.
. on the jobsite, safety is crucial for our
partners: Armstrong therefore recommends
the handling, installation & maintenance
of our solutions in accordance with the
Standards and / or regulations, for the safety
of the installers & of the end users.
1. Mark the Perimeter Trim Lines
Determine the ceiling height and level
at the perimeter with a suitable levelling
device and draw a (blue) chalk line.
NB: the minimum height of the ceiling
cavity has to be 100 mm.
Installation
In any case and for the entire range of
products, the installation must be carried out
only if the following conditions are satisfied.
1. Plaster and cement surfaces must be dry.
2. All service fittings integrated within the
suspended ceiling must be independently
supported from the ceiling grid by
a structure designed for the purpose.
3. Any thermal or acoustic insulation overlays
must be rigid and supported by the ceiling
grid or, if soft and laying onto the ceiling
tiles, must not exceed 3 kg/m2 ie glasswool
roll.
4. When the ceiling is installed under a roof
space, a study of the thermal conditions
should be made with regard for the need
of thermal insulation, vapour barrier,
ventilated roof space etc.
■
■
For products up to 70% RH, Wood
& Metal, the relative humidity must
be maintained at no more than 70%
for a temperature of 20°C. The ceiling must
not be subjected to infiltration of water.
For all the products that are 95% RH
and above the following conditions must
be respected:
2. Installation of Perimeter Trims
Fix the perimeter trims with fixings suitable
for the structure at not more than 400 mm.
35
35
Preparation of the ceiling layout
Establish a plan of your ceiling. General rule: layout the ceiling so that perimeter tiles are
in excess of ½ a module.
NB: according to the dimension of the cut tiles the central axis of the ceiling will either
be in the middle of a row of tiles or at their edge.
. The reference mark Y corresponds to the first whole tile.
Begin the layout so that the main runners are every 1200 mm apart and hangers are every
1200 mm along the main runners.
3. Installation of Hangers
Establish the location of the top fixings
(1200 x 1200 mm centres) and fix with
regard to the soffit material and load
to be carried. Engage the threaded rod into
the top fixing and with bottom nuts ready
to receive the suspension clip. Alternatively
use Quick-Hangers with top and bottom
rods bent over.
Cross
tee
120
YES
Distance between
main runners
X
120
120
Hanger
c. If the tile has to be fixed in place eg
for fire protection, smoke extract or to
counteract excessive wind pressure,
hold-down clips should be installed.
Hole
Full tile
Distance
between
hangers
35
35
c. Make sure that the edge of the first tile
corresponds well with the rout hole to be
aligned. All rout holes should be aligned
with a string or laser. Then level all main
runners and connect to the hangers.
Perimeter
cut tile
120
NO
b. Example of edge detail for MicroLook
tiles on Silhouette grid.
2. The ceiling should be installed in
the conditions stipulated in Armstrong’s
15 year warranty.
5
5
b. If the dimension of the room is greater
than the length of a main runner join two
or more sections together, by engaging
their end clips, and cut against the walls
with snips.
5. Installation of Tiles
a. Engage the tiles into the grid by lifting
them diagonally upwards through the
grid before being laid down onto the grid
flanges.
NB: Vector edged tiles are only engaged
from below the grid.
1. The room must be enclosed and the
relative humidity maintained at no more
than 95% during the installation.
5
5
4. Installation of Main Runners & Cross
Tees
a. Engage the suspension clips onto the
main runner and slide along.
d. Every 600 mm connect a 1200 mm
cross tee into the rout holes of the main
runner and lock them against the adjoining
cross tees. Then position the 600 mm
cross tee in the rout holes in the centre
of the 1200 mm cross tees to obtain a
600 x 600 mm layout. Cut perimeter cross
tees with snips.
d. Cut and reshaped edges of mineral fibre
tiles should be done with a sharp craft
knife.
Main runner
136
Note: Product availibility may vary. Please contact ITS or visit www.armstrong.eu for updated information or other sizes.
137
POST INSTALLATION
TILE INSTALLATION
The building can remain unoccupied following the ceiling installation. Therefore all precautions must be taken to prevent
condensation which could damage the ceiling. Heating should be provided at the minimum level to protect the installed
product. If necessary a study of the thermal conditions should be made to establish the dew point and need to ventilate
the ceiling cavity.
SySTeM DRaWIng
(module 600 x 600mm)
Standard lay-in installation on 24mm or 15mm exposed suspension
system for Board, Tegular or MicroLook tiles.
*reduce to 450 if heavy tile / overlays are used or heavy
service fittings are located near the perimeter.
Maintenance and cleaning
cleaning
precautions
Maintenance operations on the suspended
ceiling must only be done after the technical
impact on the ceiling has been completely
evaluated. Armstrong ceilings do not need
more maintenance than a normal painted
ceiling. However when cleaning is necessary
some precautions must be taken to preserve
the technical and aesthetic features of the
ceiling.
Dust and superficial dirt can easily be
removed with a soft brush or by use of
a vacuum cleaner. In this case use a nozzle
designed for textile surfaces and do not brush
in one direction only to avoid ingraining the
dirt into the ceiling surface. Pencil or similar
marks may be removed with a rubber eraser.
A lightly dampened cloth or sponge can also
be used but take note:
When repainting acoustical products, take
care not to block or seal perforations or
fissures otherwise the performance could
be adversely affected.
For both the installation and removal
of suspended ceilings care must be taken
to avoid generation of excessive dust.
The same applies to entry through
the ceiling into the void via access panels
or by removing tiles.
Tiles should be cut with a sharp craft knife
of electric tools. If the latter they must be
used with a vacuum dust extractor and
suitable protection masks should be worn
if the dust concentration exceeds 5 mg/m3.
ma
replaceMent of tiles and
panels
Substantial damage to the ceiling tiles
or panels can be corrected by installing
replacements. However new products may
show a colour variation when compared
to the old. In this case it is better to use
replacements from another existing area
which is not visually significant and locate
the new tiles or panels there.
. Never use abrasive products
. Ceramaguard and Newtone are 100% RH
and can be washed without risk.
. Parafon Hygien can be high-pressure
washed but only with regard of certain
conditions. Please contact Armstrong office
for details.
min
300
00*
mm
mm
m
600
0m
60
mm
m
. Some companies specialise in chemical
cleaning solutions. These should only be
undertaken after a test on a small hidden
area of the ceiling proves acceptable.
type of paint
repainting the ceiling
Whatever the application method, the
paint used must be of the highest quality.
In the case of water based paints, the
manufacturers instructions regarding thinning
and application should be followed.
Most ceiling tiles and grids can be
redecorated, however consideration should
be given to the appropriate type of paint
to be used and to the effect on the reaction
to fire and acoustic performance.
Redecoration by spraying is the preferred
method, using the minimum amount of paint
applied in an even manner. Ceiling tiles should
be removed from the grid and laid on a flat
surface prior to painting, whilst grid can be
painted in situ, but with tiles removed.
Tiles should only be moved or replaced once
dry and the grid must be dry before replacing
the ceiling tiles.
If a professional firm of decorators is used,
assurances should be sought that the
necessary performances will be maintained.
It should be noted that any repainting would
invalidate Armstrong’s warranty for the
product.
138
x6
0m
60
600
mm
Quantities required per 1m2 (no waste included)
 Tile
 Cross Tee
 Cross Tee
1200mm
600mm
0,84 lm
1,67 lm
0,84 lm
0,70 pcs
5,56 pcs
1200mm
1,67 lm
-
1,67 lm
1,40 pcs
5,56 pcs
1200mm
1200mm
0,84 lm
1,67 lm
-
0,70 pcs
5,56 pcs
600mm
1200mm
1,67 lm
-
0,84 lm
1,40 pcs
5,56 pcs
Main Runner
centres
Hanger centres
600 x 600mm
1200mm
1200mm
2,78 pcs
600mm
1200 x 600mm
1,39 pcs
 Main Runner
 Perimeter trim approx. 0,70 lm/m2
 Hanger
 Universal
retaining clip
The chart is for general guidance only.
For installation guidelines of other systems, please contact Armstrong Offices.
Please refer to Armstrong internet site, also for our free calculation software Estimate.
Note: Product availibility may vary. Please contact ITS or visit www.armstrong.eu for updated information or other sizes.
139
PLANK INSTALLATION
PLANK INSTALLATION
BoaRD, TeguLaR
(Prelude 24)
SeMI-ConCeaLeD SL2/k2C2
(Prelude 24 Main Runners)
 Main runner
 Main runner
 Long cross tee
 Z profile
 Hanger
 Spacer bar
 Perimeter trim
 Hanger
 Plank
ma
x4
00
mm
 Perimeter trim
ma
x4
300
00
 Plank
mm
/31
2.5
300
/31
2.5
L
300
2
/1
00
12
=
50
/1
50
13
/
50
ca
0
80
1
0/
200
300
/31
2.5
300
/31
2.5
300
/31
/31
2.5
300
/1
00
12
L=
15
0/
35
/1
0
25
0
00
/2
00
18
/
00
2.5
/31
2.5
BoaRD, TeguLaR,
MICRoLook* (Bandraster)
*Specific MicroLook cross tee needs
to be specified to fit with slotted Bandraster.
Please contact Internal Technical Sales
for complete information.
SeMI-ConCeaLeD SL2/k2C2
(Bandraster)
ma
x4
00
mm
 Bandraster
ca
20
0
 unslotted Z profile
30
0/
 Spacer bar
31
2.5
30
0/
 Bandraster (slotted)
 Nonius hanger
31
2.5
30
0/
 Splice
 Threaded Rod dia. 6 mm
31
2.5
30
0/
 Long cross tee
 Nonius hanger
 Perimeter trim
31
2.5
30
0/
 Perimeter trim
 Plank
31
2.5
 Wall connector
 Plank
ca
200
300
L=
/31
500
00
/18
0/
125
L
140
20
=1
0/1
/1
350
2.5
300
2
/1
00
12
50
/1
50
13
/
50
00
20
0/
80
1
0/
/31
2.5
300
/31
2.5
Note: Product availibility may vary. Please contact ITS or visit www.armstrong.eu for updated information or other sizes.
141
SERVICE INTEGRATION
SERVICE INTEGRATION
tile Mounted service fittings
recessed Modular
lighting fittings
Smaller service fittings (downlighters, smoke
detectors, sprinklers, loudspeakers etc)
if required to be integrated in the ceiling,
will have to be installed within the ceiling tile.
Armstrong grid systems are primarily
designed to carry the distributed load
of the installed tiles. However in certain
circumstances the load due to lighting and
air distribution fittings may also be supported
directly onto the ceiling grid. But great care
must be taken to avoid overloading which
could result in excessive deflection and/or
twisting of the grid.
Mineral tiles in particular, are not capable
of sustaining weighty fittings without
permanent damage and failure. In most
instances the load of such fittings must be
distributed by use of either a ceiling pattress
or else by being independently supported.
The following three generic details show
how service fittings may be integrated within
the ceiling tile and have their load transferred
on to the grid.
The third shows that it is possible for
a low weight small halogen lighting fitting
to be supported directly on the tile.
Pattress
Ceiling Tile
Grid Profile
Downlighter
Smoke Detector
Halogen Spotlight
The following generic details show how
service fittings may be integrated within
and supported on the grid. It is essential
for the specifier to investigate the
compatibility of chosen fittings and tile
systems so as to ensure unhindered site
integration.
1. Exposed Grid
Weight transferred to the grid BULB by minimum of two continuous or four discreet support
arms.
Notes:
. The above details are only indicative. It is the responsibility of the specifier or contractor to ensure that the fittings
can be supported without damage or excessive deflection of the tiles and grid.
. A pattress may be formed from gypsum board or similar thin rigid sheet. It is essential to ensure that the material chosen
has a fire reaction performance equivalent to that of the reverse face of the ceiling tile.
2. Exposed Grid
Weight transferred to the grid FLANGE by minimum of two continuous support arms.
XL2 grid will provide more resistance to eccentric bending.
Tile mounTed service fiTTings
Ceiling layouts often include linear
(continuous) lighting systems for both
functional and aesthetic reasons. Integration
of this type of lighting into a modular exposed
T or semi-concealed plank ceiling grid system
is possible and there are several alternate
ways in which it can be accomplished.
1. The modular exposed tee ceiling grid is continuous and the linear lighting is integrated by substituting
individual fittings in place of ceiling tiles in a linear pattern. With this method it is likely that the lighting fittings will
be supported on the ceiling grid. If the ceiling module is 600 x 600 and the lighting fittings are 600 x 300, then it
will be necessary to create a half module layout in one direction with one of the tiles in each module site cut to a
600 x 300 size.
3. Semi-Concealed Grid (Vector Edge)
Weight transferred to the grid BULB or to the FLANGE by minimum of two continuous or four
discreet adjustable support arms. Fitting frame dimensions must take account of Vector module.
2. The linear lighting is a continuous (independently supported) lighting trough located between areas of modular
ceiling grid. Alongside the edge of each trough are main runners that form the boundary of the modular ceiling
which will be comprised of either tiles or planks.
Notes:
The above details are only indicative. It is the
responsibility of the specifier or installer to ensure that
the lighting fittings are compatible with the ceiling
system and, in the case of example 1, that the fittings
can be supported onto the grid without damage or
excessive deflection.
142
3. The linear lighting is a continuous (independently supported) lighting trough located between areas of modular
ceiling grid. The edges of each trough are turned out so as to form a ledge upon which the ceiling system,
comprised of tiles or planks, is supported. SL2 planks may be able to span between the lighting troughs without
the aid of intermediate support. With this system spacer bars or similar ties will be needed to ensure that the
spacing between parallel troughs is maintained.
Notes:
. No fittings should share common main runners
or cross tees.
. Dynamic fittings such as ducted air diffusers should
be independently suspended and not connected
directly to the grid.
. Information on acceptable service fitting loads is
available in the Trulok Suspension Systems brochure
or from your local internal technical sales centre.
4. Semi-Concealed Grid (SL2 Edge)
Weight transferred to the grid BULB by minimum of two continuous or four discreet adjustable
support arms. Fitting frame dimensions must take account of SL2 module.
Note: Product availibility may vary. Please contact ITS or visit www.armstrong.eu for updated information or other sizes.
143