Sirocco-Manual - Airstar Safety Lighting

Transcription

Sirocco-Manual - Airstar Safety Lighting
Models Covered:
2K HA / 4K HA
600 HI-CR
1.2K HMI / 2.5K HMI
1K HI-BT37
NAFTA
Owner’s Manual
Mode d’emploi
Instrucciones de uso
Manual de instrucções
02-07-2012 / 65-63-072 B
10255 General Drive • Unit A6 • ORLANDO, FL 32824 • USA
Tel: (407)851-7870 • Fax: (407)851-7831
www.airstar-light.us • e-mail : [email protected]
1
Welcome To Airstar
Thank you for choosing AIRSTAR. Your new Sirocco unit is hand assembled with pride in USA, and we are committed to
your total customer satisfaction. Your ownership experience is extremely important to us and this user manual is designed to
help keep your Sirocco performing at its highest level.
Let There Be Light
Your Sirocco is specifically designed to provide the highest quality light for nighttime workplace safety and productivity. It is
perfect for use in a variety of worksite settings, rescue efforts, and any situation where a well-lit area is required to work.
Models Covered In This Manual
This manual covers the following Sirocco models:
- Sirocco 2K (HA 2x1000W), Sirocco 600 (HI CR 4x150W), Sirocco 250 (HI HR 250W), Sirocco 1.2K (HMI 1200W),
HMI 2.5K(HMI 2500W), Sirocco 1K (HI-BT37 1000W), Sirocco 4K HA (HA 4x1000W)
EXTREMELY IMPORTANT SAFETY INSTRUCTIONS
WARNING –
REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, EXPOSURE TO EXCESSIVE UV RADIATION, OR INJURY:
1. LIGHTED LAMPS ARE EXTREMELY HOT. Turn off, unplug, and allow unit to cool before touching lamp.
2. ALWAYS disconnect your Sirocco unit from power source prior to servicing.
3. Do Not touch lamp cage until completely cooled.
4. Do Not look directly at lighted lamp.
5. Do Not operate Sirocco unit near flammable materials.
6. Use a soft cloth or glove when handling lamps. Oil from skin may damage lamp during operation.
7. Do not operate your Sirocco with damaged electronics or if parts are missing.
8. Do not operate your Sirocco with a damaged envelope or without an envelope.
9. All service must be performed by Airstar designated technicians. See Warranty Info for details.
10. Sirocco units are designed to operate at heights of at least 5ft (1.5m).
11. Do not operate your stand-mounted Sirocco on an uneven surface or a grade of more than 8 degrees.
12. Do not use your Sirocco if wind speed exceeds 50mph (80km/h).
13. Use only recommended stands with an ability to support a 20lb (9kg) Sirocco unit, and endure wind speeds of up to
50mph (80km/h) at a height of 16.5ft (5m).
WARNING –
ALWAYS USE CORRECT LAMPS FOR YOUR SIROCCO TO AVOID DAMAGE OR INJURY:
1. Sirocco HA 2x1000W : use only with HA 1000W R7S type lamp or smaller
2. Sirocco HA 4x1000W : use only with HA 1000W R7S type lamp or smaller
3. Sirocco HI CR 4x150W 230V : use only with HCI-T/P 150W E27 type lamp or equivalent
4. Sirocco HI CR 4x150W 100-120V : use only with M102/O 150W MEDIUM type lamp or equivalent
5. Sirocco HMI 1200W : use only with HMI 1200W G38 type lamp
6. Sirocco HMI 2500W : use only with HMI 2500W G38 type lamp
7. Sirocco HI-BT37 1000W : use only with HI-BT37 M47 ANSI 1000W type lamp
WARNING
When using outdoors, basic safety precautions should always be followed to reduce the risk of fire, electric shock,
and personal injury, including the following:
1. Sirocco 2M HA / HI CR / HI HR: Use only NEMA 5-15 “Edison” plug extension cords connected to the correct voltage
electrical source outlets.
2. Always use Ground Fault Circuit Interrupter (GFCI) protection when operating your Sirocco in areas near water, and
during inclement weather.
KEEP THESE INSTRUCTIONS WITH YOUR SIROCCO UNIT
FOR QUICK REFERENCE
02-07-2012 / 65-63-072 B
2
Tips To Extend The Life Of Your Sirocco Unit
1.Use the included glove when handling lamps to prevent potential damage caused by transfer of oils and dirt to glass.
2.Always disconnect from power source before performing service.
3.Do not operate your Sirocco without its envelope or with a damaged envelope.
4.Protect the envelope by operating away from walls, projectiles, electric wires, trees, animals, etc.
5.DO NOT LEAVE DEFLATED ENVELOPE UNCOVERED OR UNATTENDED WHEN NOT IN USE.
6.Always use the included protective cover when storing your Sirocco. Failure to do so may result in loss of warranty
coverage.
7.Store your Sirocco in a dry, well-ventilated area away from heat sources and chemical products.
8.Be sure that envelope is completely dry before installing protective cover.
9.Do not use chemical solvents to clean the envelope. Use mild soap and water as necessary.
10.Do not modify the electrical components or unit structure.
11.Do not operate your Sirocco if cable is damaged, twisted, or tangled.
Recommended Generator Capacity For Sirocco Units
NOTE: When using generator power, ALWAYS start your generator BEFORE plugging in your Sirocco unit.
1.Non-Ballast Sirocco Units – Recommended Capacity :
a) Sirocco HA 2x1000W : Single phase 120V 50-60Hz – 3KVA
b) Sirocco HA 2x1000W : Single phase 230V 50-60Hz – 3KVA
c) Sirocco HA 4x1000W : Single phase 120V 50-60Hz – 5KVA
d) Sirocco HA 4x1000W : Single phase 230V 50-60Hz – 5KVA
e) Sirocco HI CR 4x150W 100-120V : Single phase 100-120V 50-60Hz – 1KVA
f) Sirocco HI CR 4x150W 230V : Single phase 230V 50-60Hz – 1KVA
2.Sirocco Units w/Ballast Regulated Power – Recommended Capacity
g) Sirocco HMI 1200W 230V : 2KVA
h) Sirocco HMI 2500W 230V : 5KVA
i) Sirocco HI-BT37 1000W 120V : 2KVA
WARNING: Be sure to avoid phase imbalance when several devices are connected to the same generator.
Built-In Safety Systems
Your Sirocco is equipped with special safety mechanisms that are designed to protect you and your Sirocco in the unlikely
event of equipment failure or in certain unsafe operating conditions:
- The Airstar Sirocco 600 (HI CR 4x150W) is equipped with a safety thermal switch that turns off the lamps if internal
operating temperature rises to unsafe levels.
- The Airstar HA, HMI, HI-T, HI-BT37 units are equipped with a safety pressure switch that turns off the lamps if internal
envelope air pressure falls below safe operating levels.
- If lamp starts blinking due to excessive heat, check and clean filter, be sure the fan is running and fresh air is circulating
through the unit. Be sure the envelope is under consistent observation.
02-07-2012 / 65-63-072 B
3
Sirocco Parts List
1
5
2*
6
3*
7
3
9
10
8
4
2
11
13
12
14
Sirocco Lamp Variations
a
b
c
d
e
*see detail at right
1
2
3
4
5
6
a
b
c
d
e
7
8
9
10
11
12
13
14
02-07-2012 / 65-63-072 B
Nut
Internal Structure (Cage + Base + Support Stem)
Envelope
Power Supply Cable
Zipper
Lamp(s) (See Lamp Variations – Pictured Above)
HA 1000W R7S lamp
HCI-T/P 150W E27 lamp
M102/O 150W MEDIUM lamp
HMI 1200W G38 lamp
HMI 2500W G38 lamp
HI-BT37 1000W E39 ANSI lamp
South Pole Plate
Stand (Recommended Accessory. Sold separately.)
Repair Kit (2 Pieces)
Protective Storage Cover
Storage Tube
User Manual
Ballast (Required For Select Models)
Cotton Glove (For Lamp Replacement)
4
Envelope Installation Instructions
·
When REPLACING an old envelope, FIRST remove original envelope:
 If currently in use, first turn unit off and let cool.
 Unplug the Sirocco unit and open the envelope zipper.
 Unscrew the nut on the top of the envelope. (Fig. 1) Set top nut in a secure place.
 Maneuver top of cage to unzipped opening and pass the cage through until fully exposed.
 Unhook the lamp holder springs (Fig. 2 – only select Sirocco models)
 Remove lamp(s) from unit. (See Lamp Replacement Instructions for detailed information on lamp removal.)
 Unplug the ground wire from the cage. (Fig. 3 black arrow)
 Unscrew the six(6) nuts on the South Pole Plate at base of cage. (Fig. 3 white arrows)
 Remove zip-ties from cage crossbar and unhook red rubber tabs. (HI CR 4x150W “Sirocco 600” model ONLY)
 Carefully remove the cage from assembly.
 Detach old envelope from assembly by sliding up along lamp assembly.
 Inspect South Pole Plate gasket (Fig. 4) for damage. Replace if damaged and ensure proper alignment.
 Slide South Pole opening of new envelope over electronic assembly.
s
Fig.
1
Fig. 3
Fig. 2
·
Install your NEW envelope:
Unfold the envelope on a smooth, clean surface.
· Open the zipper
· Position zipper on same side of unit as ground wire. (Fig. 3)
· Ensure alignment of envelope holes on South Pole Plate.
· Slide the cage inside the envelope through the zipper opening.
Fig.
4
· Align cage on South Pole baseplate with ground pin on the cage in line
with ground wire on the unit. (Fig. 3)
· Reattach ground wire to ground pin on cage.
· Screw the six(6) South Pole Plate nuts onto the cage. (Fig. 3)
· Reinstall lamp(s). (See Lamp Replacement Instructions for detailed information on lamp removal.)
· Reconnect lamp holder springs (Fig. 2 – only on select Sirocco models). Be sure to hook springs OVER the cage
crossbars.
· Loosely replace the nut on the top of the envelope. Do not tighten until after envelope is fully inflated.
· Close zipper.
· Plug Sirocco unit into appropriate power source. (CAUTION: When plugging into ballast power, always plug your
Sirocco unit into the ballast BEFORE plugging ballast into power source.)
· After envelope is fully inflated, tighten top nut.
· You are now ready to work.
Disassembly
·
Switch off, deflate, and store your Sirocco unit.
· Disconnect from power supply and let lamps cool completely. (PACKING HOT LAMPS WILL DAMAGE UNIT.)
· Open the envelope zipper to speed up deflation and cooling.
· Remove the Sirocco unit from stand or mount.
02-07-2012 / 65-63-072 B
5
·
When lamps are completely cooled, insert Sirocco unit into storage bag and store in included case. (Be sure
envelope is dry before storage!)
Lamp Replacement Instructions
· Sirocco 2K (HA 2x1000W) – (Fig. 1) & Sirocco 4K HA (HA 4x1000W) – (Fig. 2)
·
·
·
·
Unplug the Sirocco unit and open the envelope zipper. (Be sure to let unit cool.)
Using a glove, remove old lamps by grasping bulb firmly and applying downward pressure and sliding the top of the
lamp out of the fixture, then lifting the lamp up and out of the fixture.
Insert new lamps by inserting bottom of lamp into fixture, applying downward pressure, and then sliding top of lamp
into the top of the fixture.
Close the zipper.
Fig. 1
Fig. 2
· Sirocco 600 (HI CR 4x150W)
·
·
Unplug the Sirocco unit and open the envelope zipper. (Be sure to let unit cool.)
Unhook the lamp holder springs and place lamp holder aside. (Fig. 3)
Fig. 3
·
·
·
Fig. 4
Using a glove, remove the old lamps and replace with new lamps. (Fig. 4)
Replace top lamp holder and hook springs over the edge and up through lamp support plate. (Fig. 3)
Close the zipper.
02-07-2012 / 65-63-072 B
6
Lamp Replacement Instructions (cont.)
· Sirocco 1.2K (HMI 1200W)
·
·
Unplug the Sirocco unit and open the envelope zipper. (Be sure to let unit cool.)
Unhook the lamp holder springs and place lamp holder aside. (Fig. 1)
Fig. 1
·
·
·
Fig. 2
Using a glove, remove the old lamp and replace with new lamp. (Fig. 2)
Replace lamp holder and hook springs over the edge and up through lamp support plate. (Fig. 1)
Close the zipper.
· Sirocco 2.5K (HMI 2500W)
·
·
·
Unplug the Sirocco unit and open the envelope zipper. (Be sure to let unit cool.)
Using a glove, remove the old lamp and replace with new lamp. (Fig. 3)
Close the zipper
Fig. 3
02-07-2012 / 65-63-072 B
7
Lamp Replacement Instructions (cont.)
· Sirocco 1K (HI-BT37 1000W)
·
·
·
·
·
Unplug the Sirocco unit and open the envelope zipper. (Be sure to let unit cool.)
Unscrew the top-nut at the top of the envelope and set nut safely aside. (Fig. 1)
Lift envelope off of the north pole pin and carefully slide unzipped envelope opening down around cage, toward south
pole plate.
Unscrew the nylon fasteners at the base of the lamp (inside the cage) that secure the included “wrench”. (Fig. 2 –
Arrows a. & b.)
Using the “wrench”, loosen and remove the two nuts on the underside of the top brace and remove the top brace
from the cage, allowing you to access the lamp. (Fig. 3)
a.
Fig. 1
·
·
·
Fig. 3
Fig. 2
Unhook the lamp holder springs and place lamp holder aside. (Fig. 4)
Using a glove, remove the old lamp and replace with new lamp. (Fig. 5)
Replace top lamp holder and hook springs evenly around cage as shown. (Fig. 4)
Fig. 4
·
·
·
·
·
·
·
b.
Fig. 5
Reinstall the plate on the top of the cage using the “wrench”. (Fig. 3)
Reattach the included “wrench” using the included plastic thumb wheels. (Fig. 1)
Carefully guide envelope back up around cage and guide the top pin through the top of the envelope. (Fig. 1)
Loosely replace the nut on the top of the envelope. Do not tighten until envelope is fully inflated. (Fig. 1)
Close the zipper.
Plug-in the Sirocco unit to inflate the envelope.
Hand-tighten the top nut to secure envelope to the cage.
02-07-2012 / 65-63-072 B
8
In The Event Of Broken Lamp(s)
If a lamp breaks or cracks inside the envelope, disconnect the electrical power supply and disassemble the envelope. (see
Envelope Installation Instructions) Be sure to remove all fragments of glass, using a vacuum cleaner to thoroughly clean the
electronics and envelope. Handling glass fragments can cause serious injury.
Installing Your Sirocco On A Stand
NOTE:
·
·
·
·
·
Always use Airstar-approved stands designed to work with your Sirocco unit.
Always securely tighten all T-Handles to avoid injury.
Stands are designed for vertical mounting of Sirocco units ONLY.
ALWAYS use sandbags to weight stands properly. Airstar sandbags are recommended.
Using the optional Airstar ST303 (Fig. 1) or ST101 or ST201(Fig. 2) stands.
o Unfold the stand.
o Lock the base in place.
- On the ST303 (Fig. 1), lift the outer cylinder at the base slightly, then hook the oval locking ring over the
safety hook.
- On the ST101 or ST201 (Fig. 2), slide the stand legs out from the folded position until the support bars
are exactly horizontal.
o When using your stands in windy conditions, use the following weighting recommendations to keep your stand
stable.
- On the ST303 (Fig. 1), weights must be placed on each foot at 24 in (60 cm) from the center of the stand.
- On the ST101 or ST201 (Fig. 2), weights must be placed on each support at 20 in (50 cm) from the
center of the stand.
- Use the table below to determine proper sandbag weighting.
Wind speed
0 – 6 mph
6 – 12 mph
12 - 25 mph
25 - 37 mph
37 - 50 mph
Required Weight Per Leg
N/A
40 lbs
66 lbs
154 lbs
265 lbs
Fig. 1
Total Weight Required
N/A
120 lbs
140 lbs
465 lbs
795 lbs
Fig. 2
20 in (50 cm)
24in (60 cm)
Load
Load
Load
02-07-2012 / 65-63-072 B
Load
Load
Load
9
When Operating Ballast Powered Sirocco Units
·
Sirocco models that require a ballast: Sirocco 1K, Sirocco 1.2K, Sirocco 2500, and Sirocco 4K.
· ALWAYS PLUG SIROCCO UNIT INTO BALLAST BEFORE CONNECTING TO POWER OUTLET
- Connect the Sirocco power cable to the ballast.
- Securely lock the power cable connector to ballast socket.
- Connect ballast to appropriate power supply.
- Reverse procedure when shutting down your Sirocco unit.
HI-T 1000W
HI-BT37 1000W / HMI 1200W
ON
HMI 2500W
ON
OF
F
Maintenance
·
Lamp
· It is important to inspect lamps regularly, and replace lamps showing signs of wear and tear. (i.e. cracked lamp, small
fragments of glass or filament inside the lamp, or whitened lamp glass). Failure to do so could cause lamp failure, or
possibly explosion, resulting in bodily injury and/or damage to the Sirocco unit..
· To replace a lamp, please refer to “Lamp Replacement Instructions” in this manual.
·
Envelope
· A damaged envelope must be repaired or replaced immediately.
· Regularly clean the envelope with mild soap and water. Citrus-based cleaners can be used, although be sure to test
a small area before cleaning entire envelope.
·
·
Patching A Hole
o Be sure to thoroughly clean the area to be patched with mild soap and water and allow to dry.
o Cut a square patch out of the included self-adhesive fabric sheet that is one inch wider and longer than the hole
to be sure you can cover the entire damaged portion of the envelope.
o Remove the protective film from the adhesive side of the patch material.
o Carefully place the patch onto the damaged part of the envelope, firmly applying pressure to the areas of contact
around the patch edge.
Cleaning The Air Filter
· Remove sponge-type air filter, located under the
the support stand.
· Wash it or replace it
· Place clean air filter by the same way.
02-07-2012 / 65-63-072 B
south pole plate, by sliding along
10
Warranty
At Airstar, we are very proud of our quality control and the reliability of our Sirocco product line. We also understand that
there will occasionally be issues that require warranty service, so we offer the following coverage:
·
·
·
·
·
·
Your Sirocco envelope, electronics, and structural components (excluding lamps) are guaranteed against manufacturing
defects for 1 (one) year from the date of purchase.
In the event of a manufacturing defect or possible warranty issue, call your Authorized Airstar Dealer to initiate a warranty
claim.
Send your Sirocco unit, along with a copy of your original invoice, to your Authorized Airstar Dealer for technical analysis.
An Airstar certified technician will determine if your issue is covered under warranty.
After repair, Airstar will return your Sirocco at our expense, via ground shipping. (Express available at extra charge.)
If complete unit replacement is required, Airstar only ship replacement unit after receiving original unit.
Airstar will not be held responsible for improper handling by the end user. Any operations on the envelope or electronic
equipment that is not described in this manual, or any use of unapproved tools, components or lamps is not covered by this
warranty and remains the sole responsibility of the user.
Technical Data Sheet
Sirocco 2 M
Sirocco 2 M
Sirocco 2 M
Technical data sheets Units HA 2x1000W HA 4x1000W HI CR 4x150W E27
Sirocco 2 M
HI-BT37
1000W
Sirocco 2 M
HMI 1200W
120V
60Hz
230V
50Hz
Sirocco 2 M
HMI 2500W
V
Hz
Lm
W
120V
60Hz
120
60Hz
54000 Lm
108000 Lm
58000 Lm
115000 Lm
110000 Lm
2
4
4
1
1
1
1000 W
1000 W
1200 W
2500 W
Bulb type
-
HA
HA
HMI
HMI
Bulb socket
Restrike type
Restrike time
Power supplied by
exterior ballast
Colour temperature
Average bulb life
s
R7S
R7S
1000 W
HI-BT37
M47 ANSI
E39
G38
G38
Hot
Hot
Cold
Cold
Hot
Hot
Instant
Instant
>7 minutes
>7 minutes
<10 seconds
<10 seconds
-
No
No
No (Built-In)
Yes
Yes
Yes
°K
h
3200° K
3200° K
3000° K
3700° K
5600° K
5600° K
300 h
300 h
12,000 h
12,000 h
750 h
500 h
-
Pressure
switch
Pressure
switch
Thermal cut-off
Pressure
switch
Pressure
switch
Pressure
switch
Power supply
Luminous flux
Lamp Qty
Power Per Lamp
Protection type
Anti-vibration system
Envelope diameter
in.
Envelope shape
Bulb luminous
Lw/W
efficacy
Weight
lbs
Power
W
Power generating unit KVA
02-07-2012 / 65-63-072 B
120V
60Hz
220V
60Hz
150 W
MetalMetalhalide
halide
MEDIUM
E27
208V
60Hz
230V
50Hz
240000Lm
Yes
Yes
Yes
Yes
Yes
Yes
35.5 in
47 in
35.5 in
47 in
47 in
55 in
Tubular
Tubular
Tubular
Tubular
Tubular
Tubular
27 Lm/W
27 Lm/W
97 Lm/W
115 Lm/W
92 Lm/W
96 Lm/W
11 lbs
20.7 lbs
16.5 lbs
14.3 lbs
16.5 lbs
18.3 lbs
2020 W
4020 W
690 W
1100 W
1300 W
2700W
3 KVA
5 KVA
1 KVA
2 KVA
2 KVA
5 KVA
11
10255 General Drive • Unit A6 • ORLANDO, FL 32824 • USA
Tel: (407)851-7870 • Fax: (407)851-7831
www.airstar-light.us • e-mail : [email protected]
02-07-2012 / 65-63-072 B
12