Unicab-Vario

Transcription

Unicab-Vario
Unicab-Vario
Outdoor Active Cabinet
Description
Features and Benefits
The Unicab-Vario cabinet is a
double-walled, weatherproof,
protective outdoor cabinet
that accommodates electronic
equipment, guaranteeing reliable
functionality.
• Maintenance-free surface made of
environmentally resistant plastic
The Unicab-Vario cabinet protects
components against the effects of
weather and extreme temperatures.
Applications
• Telecommunications: collocation,
xDSL, UMTS, cable television, DLC,
RSLU
• Electronics: measurement and
control
• Traffic control technology
• Constructed of recyclable materials,
the double-walled cabinet assures
optimum interior climate control
• Light-weight in comparison with
metal cabinets of the same size
and function
• Can be delivered completely
assembled or as a kit
• Passive or active cooling systems
available
• Flexible mounting arrangements
for components, meeting either
ETSI or 19-inch standards
• Installs over existing housing
and plinth providing economic
alternative to new builds
• Replacement of external housing
parts possible without interruption
of service
The housing consists of a metal inner shell with a plastic
outer shell made of fibreglass-reinforced polycarbonate. For over 25 years, this plastic has proven durable
in cross-connection cabinets for major communications
service providers around the world. The outer dimensions satisfy the international guidelines EN 301169-2.
The plastic roof (1) features a water-drip protection lip
on both the front and the back of the cabinet. Cabinets
can be installed side-by-side. On the sides of the roof,
there are small areas for customer-specified identification. Slots provide air exchange for climate control of
installed components.
The outer plastic shell (3) is fixed to the frame and can
be installed or removed part-by-part (side panels, back
wall, doors) without interruption of service.
• The outer surface of the doors and back are
vertically fluted, making it difficult to affix illegal
posters (3a).
• The doors have a 3-point locking mechanism and
can be held open. Available accessories include:
- Double or single locking mechanisms with
revolving handle for profile cylinders (satisfying
DIN 18252)
- Door contact sensors
• Hidden closing and locking elements make
vandalism difficult
• Removable front panel, locked from within, for
access to lower part of the cabinet (4b).
The inner structural frame (4) made of aluminium profile
rods, creates a closed metal inner shell when metal
shielding sheets (5), base plates (6) and shielding sheets
on the inside of the door (7) are installed.
Designed for installation of
- a frame (8) for mounting chassis (satisfies ETSI
standard ETS 300 199-4, as well as 19-inch standards)
- cable connection and distribution equipment for
both copper and fibre optic networks
• Mounting plates, frames or rails are available for
customer-specific solutions.
The base plate (6) protects the inner space against
moisture rising from the ground. It provides a sealed
feed-in area for underground cables.
Divides the cabinet into a component accommodation
area.
• (4a) above the base plate
• (4b) below the base plate, for the installation of buffer
batteries, as well as cable and plinth mounting elements
The base plate can be delivered either with cable
grommets or closed without cable entries. The closed
base plate is opened by the customer as required for
cable feed-in.
(1)
(3)
(7)
(3a)
(3b)
(2)
(4)
(4a)
(8)
(5)
(4b)
(6)
(9)
(12)
(11)
Dimensions
The plinth (9) is made of steel and the separation point
between the cabinet and the plinth is at just above ground
level. Support grids with large surface areas (10) distribute
the cabinet's weight over the bottom of the excavation.
Plastic sheets (11) cover the plinth's upper half. Cable
routing elements are available for guiding cables into
the cabinet and ensure that the minimum bend radius is
maintained. Cable conduit pipes can be connected over
a cable connection. Predetermined break-point elements
form the interface between the cabinet and the plinth
(12). These reduce the effect of accidents, since the plinth,
which is in the ground, usually remains undamaged. As
a result, expensive excavation work after accidents is
usually not necessary. Defective predetermined break-point
elements can be easily replaced. A steel carrier is available
for Unicab-Vario installations on concrete slabs or on
rooftops.
Environmental module (2)
Depending on the energy generated by the installed equipment and the temperature difference to the outside, the
cabinet's inner space will become warm. Without proper
ventilation, the temperature can exceed the permissible
ambient temperature for the installed equipment. This problem can be solved by use of a suitable cooling design. The
cabinet´s outer plastic shell is made of polycarbonate which
has excellent thermal insulation properties. This minimises
the heating effects of direct sunlight on the cabinet. Two
cooling methods are available, passive and active; both
methods protect the inner space from environmental hazards such as dust or water.
Options for climatisation
Fixed-line carriers all over the world are deploying active electronic equipment in external cabinets throughout
their distribution networks as they deliver advanced broadband data, voice and video services to their business
and residential customers.
Active equipment must be housed in a sealed environment regulating both temperature and moisture, which,
if not properly controlled, can seriously and adversely affect equipment reliability and service-life. Connectivity
such as cross-connect equipment also benefits from a controlled environment.
The Unicab-Vario cabinet offers a secure, customizable environment for housing both active and passive equipment, and support use of copper- and fiber-based technologies. Four options of cabinet climatisation are
available
•
•
•
•
Passive
Roof fan (forced aeration)
Heat exchanger
Air conditioner
All active climatisation devices are located in the cabinet roof, assuring easy retrofit and interchangeability of
devices.
The following must be considered when choosing the correct method of climatisation for a given installation:
•
•
•
•
•
What devices will be installed in the cabinet
What are the dimensions (height by width by depth) of each device
What is the maximum working temperature of each device
What is the power (heat) dissipation of each device
What is the maximum ambient temperature (without sun radiation) in the area of installation
Passive cooling
Active cooling
The energy given off by the active components warms the
inner metal shell. The cooler air circulating between the
inner and outer shells (chimney effect) leads the heat out
over the roof. To enhance the cooling effect and to avoid
hot spots, fans should be used to increase air circulation.
• No ingress of dust or humidity
• Plastic outer shell reduces influence of solar radiation
Heat is dissipated by placing a cooling device inside the
roof. This environmental module increases the dissipation
of heat.
Roof fan (forced aeration)
•
•
•
Fans increase air speed in space between outer and inner wall, increasing the rate of heat removal
No ingress of dust or humidity
Compartment is IP55 protected
Air-to-Air heat exchanger
•
•
Absorbs heat of internally and externally circulated air
Basic components include:
1
Heat exchanger
2
Internal fan
3
Outer fan
4
Control board
5
Connectors
6
Temperature sensor
Air conditioner
•
•
•
Separate air flow circuits prevent ingress of dust and humidity
Inner air circuit transfers heat from the inside of the cabinet to the vaporisation unit
Outer air circuit transfers the heat from the condenser unit to the outside
Optional Accessories
Frame for ETSI and 19” components
•
•
•
•
Includes mounting hardware
Two mounting rails (ETSI/19”) with metric pitch satisfying DIN 43356 and 19” width (ASA)
Usable height: 21 RU (38 SU) (933.45mm)
Four PROFIL rods with a 12.5mm pitch for individual installation of the mounting rails at various depths
Pivoting frame
•
•
•
•
•
For installation of ETSI or 19” chassis
Dimensions (H x W): 1000mm x 540mm (590mm)
Usable height: 21 RU (38 SU) (933.45mm)
Maximum installation height: 370mm
Maximum permissible load: 50kg
Cable head frame
•
•
For cable head 1-, 2- and 3- bay: Up to 300 pairs Series 2 or 400 pairs NT modules
For PROFIL 3-bay: for mounting in ETSI frame of different heights (200, 600, 800mm)
Fan system for forced aeration
•
•
•
•
Installed in roof of Unicab-Vario cabinet
48 VDC
Temperature regulated
Thermal output: 20 to 27 W/K with maximum noise of 45 dB(A)
Air-to-air heat exchanger
•
•
•
•
•
Installed in roof of Unicab-Vario cabinet
48 VDC
Temperature regulated
Thermal output: (depending on cabinet and heat exchanger) Typically 26W/K (50dBA) … 87W/K (50dBA)
Optional integrated temperature-controlled heating element available: 230V/950W
Air conditioner
•
•
•
•
•
Installs in roof of Unicab-Vario cabinet
230 VAC/17A
Temperature regulated
Specific thermal output: 1300W for 45 C/45 C
Optional integrated temperature-regulated heating element available: 230V/950W
Power distribution
•
•
•
•
•
•
Includes mounting hardware and earthing kit
Various sub-distributions with quick-acting fuses, equipment supply outlets and up to a maximum of
5 electrical circuits over an automatic circuit breaker in accordance with DIN/VDE 0100
Available with optional housing for installation of electrical meter and a housing to accommodate a low-voltage
power fuse
19” chassis (3RU), for energy distribution, custom-configurable
Energy distribution components must be ordered separately
Battery trays
• Can be installed like a drawer, or in fixed position base plates
Base plates
•
Available with cable inlets of various designs
Door contact
•
Signals that a door is open or closed
Product Specifications
Empty Cabinet
Electrical characteristics
Heat dissipation capacity
Passive (convective ventilation)
Active (with air-to-air heat exchanger)
Active (with cooling equipment)
10 W / K to 18 W / K
45 W / K
1200 W (45 K / 45 K)
Temperature characteristics
Ambient temperature
-40ºC to +50ºC
Mechanical characteristics
Plastic shell (outer housing)
Plinth cover
Seals
Flammability class
Inner housing:
Other parts
Recycling
Protection class (internal housing)
Weight
1 door
2 doors
3 doors
Cabinet
~115 kg
~150 kg
~185 kg
Fibreglass reinforced polycarbonate, painted grey
(similar to RAL 7038)
Fibreglass reinforced polycarbonate, unpainted
Santoprene
UL94V0
Chrome-plated aluminium
Stainless steel or steel, galvanised and chrome-plated
Materials can be separated for recycling
IP 55 according to IEC 529
Plinth
~51 kg
~60 kg
~75 kg
Ordering information
Description
Catalogue number
Unicab-Vario 1050, one door cabinet
(door equipped with pivoted locking handle with double locking mechanism,
for installation of two half profile cylinders). Unless otherwise stated, base plate,
frame and plinth are ordered separately
7056 1 001-00
Unicab-Vario 1450, two door cabinet
(doors equipped with pivoted locking handle with double locking mechanism,
for installation of two half profile cylinders). Base plate, frame and plinth are oreder separately
7056 1 002-00
Unicab-Vario 2050, three door cabinet
(doors equipped with pivoted locking handle with double locking mechanism,
for installation of two half profile cylinders). Doors on the left and right are hinged:
removable middle door.Base plate, frame and plinth are oreder separately
7056 1 003-00
Unicab, TE (logo) and TE Connectivity are trademarks of the TE Connectivity group of companies and its licensors. PROFIL is a trademark.
The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE
Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity’ s obligations shall only be as set
forth in TE Connectivity’s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential
damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of
each such product for the specific application.
Tyco Electronics Raychem bvba
Diestsesteenweg 692
3010 Kessel-Lo, Belgium
Tel 32-16 351 011
(USA)1-919-557-8900
Fax 32-16 351 697 (USA)1-919-557-8498
www.te.com
www.telecomnetworks.com
TC 1125/BR/1 04/12