Neutron Engineering Inc.

Transcription

Neutron Engineering Inc.
RV-0000000
Neutron Engineering Inc.
EMC Test Report
Jan. 02, 2014
1311149
IPC
AMOS-820; CPT-1000; AMOS-820-P
Issued Date
Project No.
Equipment
Model Name
:
:
:
:
Applicant
Address
: VIA Technologies, Inc.
: 1F, 531, Zhongzheng Rd. Xindian
District, New Taipei City 231 Taiwan
ra
ft
Tested by: Neutron Engineering Inc. EMC Laboratory
Date of Receipt: Nov. 15, 2013
Date of Test: Nov. 15, 2013 ~ Dec. 31, 2013
Te s t i n g E n g i n e e r :
(Pike Lee)
D
Technical Manager :
(Jeff Yang)
Authorized Signatory :
(Andy Chiu)
Neutron Engineering Inc.
B1, No. 37, Lane 365, YangGuang St.,
NeiHu District 114, Taipei, Taiwan.
TEL: +886-2-2657-3299
FAX: +886-2-2657-3331
Report No.: NEI-EMC-1-1311149
Page 1 of 170
Neutron Engineering Inc.
RV-0000000
Declaration
Neutron represents to the client that testing is done in accordance with standard procedures as applicable
and that test instruments used has been calibrated with the standards traceable to National Measurement
Laboratory (NML) of R.O.C., or National Institute of Standards and Technology (NIST) of U.S.A.
Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s
responsibility to ensure that additional production units of this model are manufactured with the identical
electrical and mechanical components. Neutron shall have no liability for any declarations, inferences or
generalizations drawn by the client or others from Neutron issued reports.
Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any
agency of the Government.
This report is the confidential property of the client. As a mutual protection to the clients, the public and
Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized
written approval.
Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025
requirements, and accredited by the conformity assessment authorities listed in this test report.
Limitation
D
ra
ft
For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this
test report is (are) included in the conformity assessment authorities acceptance respective.
Report No.: NEI-EMC-1-1311149
Page 2 of 170
Neutron Engineering Inc.
Table of Contents
RV-0000000
Page
REPORT ISSUED HISTORY
6 1 . CERTIFICATION
7 2 . SUMMARY OF TEST RESULTS
8 9 2.1 TEST FACILITY
2.2 MEASUREMENT UNCERTAINTY
3 . GENERAL INFORMATION
10 12 3.1 GENERAL DESCRIPTION OF EUT
12 3.2 DESCRIPTION OF TEST MODES
13 3.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 16 3.4 DESCRIPTION OF SUPPORT UNITS
20 ft
4 . EMC EMISSION TEST
19 20 20 20 21 21 21 22 23 4.2 CONDUCTED EMISSION AT TELECOMMUNICATION PORTS TEST
4.2.1 LIMITS
4.2.2 MEASUREMENT INSTRUMENTS LIST
4.2.3 TEST PROCEDURE
4.2.4 DEVIATION FROM TEST STANDARD
4.2.5 TEST SETUP
4.2.6 EUT OPERATING CONDITIONS
4.2.7 TEST RESULTS
33 33 33 34 34 34 34 35 4.3 RADIATED EMISSION TEST
4.3.1 LIMITS
4.3.2 MEASUREMENT INSTRUMENTS LIST
4.3.3 TEST PROCEDURE
4.3.4 DEVIATION FROM TEST STANDARD
4.3.5 TEST SETUP
4.3.6 EUT OPERATING CONDITIONS
4.3.7 TEST RESULTS-BELOW 1 GHZ
4.3.8 TEST RESULTS-ABOVE 1 GHZ
54 54 55 56 57 57 57 58 72 4.4 HARMONIC CURRENT EMISSIONS TEST
4.4.1 LIMITS
86 86
D
ra
4.1 CONDUCTED EMISSION TEST
4.1.1 LIMITS
4.1.2 MEASUREMENT INSTRUMENTS LIST
4.1.3 TEST PROCEDURE
4.1.4 DEVIATION FROM TEST STANDARD
4.1.5 TEST SETUP
4.1.6 EUT OPERATING CONDITIONS
4.1.7 TEST RESULTS
Report No.: NEI-EMC-1-1311149
Page 3 of 170
RV-0000000
Neutron Engineering Inc.
Table of Contents
Page
86 87 87 87 87 88 4.4.2 MEASUREMENT INSTRUMENTS LIST
4.4.3 TEST PROCEDURE
4.4.4 DEVIATION FROM TEST STANDARD
4.4.5 TEST SETUP
4.4.6 EUT OPERATING CONDITIONS
4.4.7 TEST RESULTS
103 103 103 103 103 104 104 105 4.5 VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER TEST
4.5.1 LIMITS
4.5.2 MEASUREMENT INSTRUMENTS LIST
4.5.3 TEST PROCEDURE
4.5.4 DEVIATION FROM TEST STANDARD
4.5.5 TESTSETUP
4.5.6 EUT OPERATING CONDITIONS
4.5.7 TEST RESULTS
5 . EMC IMMUNITY TEST - EN 55024
110 110 5.2 GENERAL PERFORMANCE CRITERIA
111 5.3 GENERAL PERFORMANCE CRITERIA TEST SETUP
111 ra
ft
5.1 STANDARD COMPLIANCE/SERVRITY LEVEL/CRITERIA
112 112 112 112 113 113 114 D
5.4 ELECTROSTATIC DISCHARGE IMMUNITY TEST (ESD)
5.4.1 TEST SPECIFICATION
5.4.2 MEASUREMENT INSTRUMENTS
5.4.3 TEST PROCEDURE
5.4.4 DEVIATION FROM TEST STANDARD
5.4.5 TEST SETUP
5.4.6 TEST RESULTS
5.5 RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY
TEST (RS)
5.5.1 TEST SPECIFICATION
5.5.2 MEASUREMENT INSTRUMENTS
5.5.3 TEST PROCEDURE
5.5.4 DEVIATION FROM TEST STANDARD
5.5.5 TEST SETUP
5.5.6 TEST RESULTS
125 125 125 125 125 126 127 5.6 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (EFT/BURST)
5.6.1 TEST SPECIFICATION
5.6.2 MEASUREMENT INSTRUMENTS
5.6.3 TEST PROCEDURE
5.6.4 DEVIATION FROM TEST STANDARD
5.6.5 TEST SETUP
5.6.6 TEST RESULTS
128 128 128 128 128 129 130 5.7 SURGE IMMUNITY TEST
132
Report No.: NEI-EMC-1-1311149
Page 4 of 170
RV-0000000
Neutron Engineering Inc.
Table of Contents
Page
132 132 132 133 133 134 5.7.1 TEST SPECIFICATION
5.7.2 MEASUREMENT INSTRUMENTS
5.7.3 TEST PROCEDURE
5.7.4 DEVIATION FROM TEST STANDARD
5.7.5 TEST SETUP
5.7.6 TEST RESULTS
5.8 IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY
135 135 135 135 135 136 137 RADIO-FREQUENCY FIELDS TEST (CS)
5.8.1 TEST SPECIFICATION
5.8.2 MEASUREMENT INSTRUMENTS
5.8.3 TEST PROCEDURE
5.8.4 DEVIATION FROM TEST STANDARD
5.8.5 TEST SETUP
5.8.6 TEST RESULTS
139 139 139 139 139 140 141 ra
ft
5.9 POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST (PFMF)
5.9.1 TEST SPECIFICATION
5.9.2 MEASUREMENT INSTRUMENTS
5.9.3 TEST PROCEDURE
5.9.4 DEVIATION FROM TEST STANDARD
5.9.5 TEST SETUP
5.9.6 TEST RESULTS
5.10 VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS
D
IMMUNITY TEST
5.10.1 TEST SPECIFICATION
5.10.2 MEASUREMENT INSTRUMENTS
5.10.3 TEST PROCEDURE
5.10.4 DEVIATION FROM TEST STANDARD
5.10.5 TEST SETUP
5.10.6 TEST RESULTS
6 . EUT TEST PHOTO
Report No.: NEI-EMC-1-1311149
142 142 142 142 142 143 144 145 Page 5 of 170
Neutron Engineering Inc.
RV-0000000
REPORT ISSUED HISTORY
Description
Initial Issue.
Issued Date
Jan. 02, 2014
D
ra
ft
Revised Version No.
-
Report No.: NEI-EMC-1-1311149
Page 6 of 170
Neutron Engineering Inc.
RV-0000000
1. CERTIFICATION
Equipment :
Brand Name :
Model Name :
Applicant:
Date of Test :
Sta n d a r d s :
IPC
VIA
AMOS-820; CPT-1000; AMOS-820-P
VIA Technologies, Inc.
Nov. 15, 2013 ~ Dec. 31, 2013
EN 55022: 2010 +AC: 2011 Class A
EN 61000-3-2: 2006 +A1: 2009 +A2: 2009 Class D
EN 61000-3-3: 2008
EN 55024: 2010
IEC 61000-4-2: 2008
IEC 61000-4-3: 2006 +A1: 2007 +A2: 2010
IEC 61000-4-4: 2012
IEC 61000-4-5: 2005
IEC 61000-4-6: 2008
IEC 61000-4-8: 2009
IEC 61000-4-11: 2004
D
ra
ft
The above equipment has been tested and found compliance with the requirement of the relative
standards by Neutron Engineering Inc. EMC Laboratory.
The test data, data evaluation, and equipment configuration contained in our test report (Ref No.
NEI-EMC-1-1311149) were obtained utilizing the test procedures, test instruments, test sites that
has been accredited by the Authority of TAF according to the ISO-17025 quality assessment
standard and technical standard(s).
Report No.: NEI-EMC-1-1311149
Page 7 of 170
RV-0000000
Neutron Engineering Inc.
2. SUMMARY OF TEST RESULTS
Test procedures according to the technical standards:
Emission
Standard
Test Item
Limit
Judgment
Conducted emission
Class A
PASS
Conducted emission at
telecommunication ports
Class A
PASS
Radiated emission Below 1 GHz
Class A
PASS
Radiated emission Above 1 GHz
Class A
PASS
NOTE (2)
Standard
Test Item
Limit
Judgment
Remark
EN 61000-3-2: 2006
+A1: 2009 +A2: 2009
Harmonic current emissions
Class D
PASS
NOTE (3)
EN 61000-3-3: 2008
Voltage changes, voltage
fluctuations and flicker
------
PASS
EN 55022: 2010
+AC: 2011
Remark
ft
Immunity
EN 55024: 2010
Test Item
Performance
Criterion
Judgment
IEC 61000-4-2: 2008
Electrostatic discharge immunity
B
PASS
IEC 61000-4-3: 2006
+A1: 2007 +A2: 2010
Radiated, radio-frequency,
electromagnetic field immunity
Electrical fast transient/burst
immunity
A
PASS
B
PASS
B/C
PASS
A
PASS
A
PASS
B/C/C
PASS
IEC 61000-4-4: 2012
Surge immunity
Immunity to conducted
disturbances, induced by
radio-frequency fields
Power frequency magnetic field
immunity
Voltage dips, short interruptions
and voltage variations immunity
D
IEC 61000-4-5: 2005
ra
Section
IEC 61000-4-6: 2008
IEC 61000-4-8: 2009
IEC 61000-4-11: 2004
NOTE(5)
Remark
NOTE (4)
NOTE:
(1) ”N/A” denotes test is not applicable in this Test Report.
(2) If the EUT’s max operating frequency does not exceed 108 MHz, the test will not be performed.
(3) If the EUT’s category is Class D and power consumption is less than 75W, there is no limit applied.
(4) Performance Criterion C for signal ports and telecommunication ports.
Performance Criterion B for input d.c. power port and a.c. power ports.
(5) Voltage Dips: >95% reduction – Performance Criterion B
Voltage Dips: 30% reduction – Performance Criterion C
Voltage Interruptions: >95% reduction – Performance Criterion C
Report No.: NEI-EMC-1-1311149
Page 8 of 170
Neutron Engineering Inc.
RV-0000000
2.1 TEST FACILITY
The test facilities used to collect the test data in this report:
Conducted emission Test:
C03: (VCCI RN: C-4461)
B1, No. 37, Lane 365, YangGuang St., NeiHu District 114, Taipei, Taiwan.
Conducted emission at telecommunication ports Test:
C03: (VCCI RN: T-1667)
B1, No. 37, Lane 365, YangGuang St., NeiHu District 114, Taipei, Taiwan.
Radiated emission Test (Below 1 GHz):
OS02: (VCCI RN: R-2669; FCC RN: 95335; FCC DN: TW1010)
No.132-1, Ln. 329, Sec. 2, Balian Rd., Xizhi Dist., New Taipei City 221, Taiwan (R.O.C.)
Radiated emission Test (Above 1 GHz):
CB08: (VCCI RN: G-91; FCC RN: 614388; FCC DN: TW1054; IC Assigned Code: 4428C-1)
1F., No. 61, Ln. 77, Sing-ai Rd., Neihu Dist., Taipei City 114, Taiwan (R.O.C.)
D
ra
ft
The immunity test facilities are located at:
B1, No. 37, Lane 365, YangGuang St., NeiHu District 114, Taipei, Taiwan.
Report No.: NEI-EMC-1-1311149
Page 9 of 170
RV-0000000
Neutron Engineering Inc.
2.2 MEASUREMENT UNCERTAINTY
The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a
standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
approximately 95%.
The measurement instrumentation uncertainty considerations contained in CISPR 16-4-2.
A. Conducted emission test:
Test Site
Measurement Frequency Range
C03
150 kHz ~ 30 MHz
U,(dB)
1.94
NOTE
B. Conducted emission at telecommunication ports test:
Test Site
Measurement Frequency Range
C03
150 kHz ~ 30 MHz
U,(dB)
1.94
NOTE
U,(dB)
NOTE
CB08
Radiated
emission at
3m
Measurement Frequency Range
30 - 200MHz
200 - 1000MHz
Horizontal
Polarization
1 - 18GHz
18 - 40GHz
30 - 200MHz
200 - 1000MHz
Vertical
Polarization
1 - 18GHz
18 - 40GHz
ra
Item
2.48
2.16
2.50
2.66
Uncertainty
3.35 dB
3.11 dB
3.97 dB
4.01 dB
3.22 dB
3.24 dB
4.05 dB
4.04 dB
NOTE
D
Test Site
Ant.
H/V
V
H
V
H
ft
C. Radiated emission test:
Measurement Frequency
Test Site
Range
30 MHz ~ 200 MHz
30 MHz ~ 200 MHz
OS02
200 MHz ~ 1, 000 MHz
200 MHz ~ 1, 000 MHz
D. Harmonic current emissions and Voltage changes, voltage fluctuations and flicker test:
Item
Expanded Uncertainty
NOTE
Voltage
0.04 %
Harmonic current emissions
Current
191 %
Frequency
2.8x10-10
Voltage
0.04 %
Voltage changes, voltage fluctuations
Current
191 %
and flicker
Frequency
2.8x10-10
Report No.: NEI-EMC-1-1311149
Page 10 of 170
RV-0000000
Neutron Engineering Inc.
E. Immunity tests:
Item
Electrostatic Discharge Immunity
Radiated, Radio-frequency,
Electromagnetic Field Immunity
Expanded Uncertainty
Voltage
1.6 %
Timing
2.8 %
NOTE
2.66 dB
80MHz - 2.5GHz, k=2
Voltage
1.6 %
Frequency 2.8x10-10
Timing
2.8 %
Voltage
1.6 %
Surge Immunity
Timing
2.8 %
1.75 dB
Immunity to Conducted Disturbances, CDN
Induced by Radio-frequency Fields
EM Clamp
1.47 dB
Power Frequency Magnetic Field
1%
Immunity
1.6 %
Voltage Dips, Short Interruptions and Voltage
Voltage Variations Immunity
Timing
2.8 %
Electrical Fast Transient/Burst
Immunity
150KHz - 80GHz, k=2
150KHz - 80GHz, k=2
D
ra
ft
Our calculated Measurement Instrumentation Uncertainty is shown in the tables above.
These are our Ulab values in CISPR 16-4-2 terminology.
Since Table 1 of CISPR 16-4-2 has values of measurement instrumentation uncertainty,
called UCISPR, as follows:
Conducted Disturbance (mains port) – 150 kHz – 30 MHz : 3.6 dB
Radiated Disturbance (electric field strength on an open area test site or alternative test
site) – 30 MHz – 1000 MHz : 5.2 dB
It can be seen that our Ulab values are smaller than UCISPR.
Report No.: NEI-EMC-1-1311149
Page 11 of 170
RV-0000000
Neutron Engineering Inc.
3. GENERAL INFORMATION
3.1 GENERAL DESCRIPTION OF EUT
Equipment
IPC
Brand Name
VIA
Model Name
AMOS-820; CPT-1000; AMOS-820-P
OEM Brand/Model Name N/A
There are three models based on similar electrical circuit
except the difference of list below:
Model Name
Model Difference
ft
AMOS-820
AMOS-820-P
CPT-1000
All the above models were evaluated and used for final
testing and collecting test data included in this report.
The EUT is an IPC.
More details of EUT technical specification, please refer to
the User's Manual.
A. DC Voltage supplied from External Power Supply.
B. DC Voltage supplied from PoE.
A. 1. EUT Rating: I/P DC 12V
2. External Power Supply:
(1) DELTA, ADP-18TB A (only for AMOS-820 and AMOS-820-P)
I/P: AC 100-240V 0.6A 50-60Hz / O/P: DC 12V 1.5A
(2) FSP, FSP060-DBAB1 (only for AMOS-820 and AMOS-820-P)
I/P: AC 100-240V 1.5A 50-60Hz / O/P: DC 12V 5A
MAX (60W MAX)
(3) DELTA, ADP-36JH B (only for CPT-1000)
I/P: AC 100-240V 1A 50-60Hz / O/P: DC 12V 3A
B. PoE: I/P DC 48V(only for CPT-1000 and AMOS-820-P)
Please refer to the User's Manual
1 * CPU: 1.0GHz Freescale i.MX 6Quad ARM Cortex-A9
1 * RAM: 1GB DDR3
1 * External Power Supply:
(1) DELTA, ADP-18TB A (only for AMOS-820 and AMOS-820-P)
(2) FSP, FSP060-DBAB1(only for AMOS-820 and AMOS-820-P)
(3) DELTA, ADP-36JH B (only for CPT-1000)
N/A
D
ra
Product Description
Power Source
Differences
Power Board
POE
X
X
X
O
O
O
Power Rating
Connecting I/O Port(s)
Products Covered
EUT Modification(s)
Note:
1. For a more detailed features description, please refer to the manufacturer’s specifications or the User's
Manual.
Report No.: NEI-EMC-1-1311149
Page 12 of 170
RV-0000000
Neutron Engineering Inc.
3.2 DESCRIPTION OF TEST MODES
To investigate the maximum EMI emission characteristics generates from EUT, the test system
was pre-scanning tested base on the consideration of following EUT operation mode or test
configuration mode which possible have effect on EMI emission level. Each of these EUT
operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively.
Pretest Test Mode
Description
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter :
FSP060-DBAB1)
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter :
ADP-18TB A)
Mode 1
Mode 2
Mode 3
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B)
Mode 4
FULL SYSTEM (CPT-1000) (PoE)
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1)
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:ADP-18TB A)
Mode 5
Mode 6
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (PoE)
ft
Mode 7
Conducted emission test
Description
ra
Final Test Mode
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter :
FSP060-DBAB1)
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter :
ADP-18TB A)
Mode 1
Mode 2
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B)
D
Mode 3
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1)
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:ADP-18TB A)
Mode 5
Mode 6
Conducted emission at telecommunication ports test
Final Test Mode
Mode 1
Mode 1
Mode 1
Mode 2
Mode 2
Mode 2
Mode 3
Description
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter :
FSP060-DBAB1) (ETHERNET 1G-1G)
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter :
FSP060-DBAB1) (ETHERNET 100M-100M)
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter :
FSP060-DBAB1) (ETHERNET 10M-10M)
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter :
ADP-18TB A) (ETHERNET 1G-1G)
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter :
ADP-18TB A) (ETHERNET 100M-100M)
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter :
ADP-18TB A) (ETHERNET 10M-10M)
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B) (ETHERNET
1G-1G)
Report No.: NEI-EMC-1-1311149
Page 13 of 170
RV-0000000
Neutron Engineering Inc.
Mode 3
Mode 3
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B) (ETHERNET
100M-100M)
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B) (ETHERNET
10M-10M)
Mode 4
FULL SYSTEM (CPT-1000) (PoE) (ETHERNET 100M-100M)
Mode 4
FULL SYSTEM (CPT-1000) (PoE) (ETHERNET 10M-10M)
Mode 5
Mode 5
Mode 6
Mode 6
Mode 6
Mode 7
Mode 7
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1) (ETHERNET 1G-1G)
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1) (ETHERNET 100M-100M)
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1) (ETHERNET 10M-10M)
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:ADP-18TB A) (ETHERNET 1G-1G)
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:ADP-18TB A) (ETHERNET 100M-100M)
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:ADP-18TB A) (ETHERNET 10M-10M)
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (PoE)
(ETHERNET 100M-100M)
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (PoE)
(ETHERNET 10M-10M)
ft
Mode 5
Final Test Mode
Mode 1
Description
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter :
FSP060-DBAB1)
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter :
ADP-18TB A)
D
Mode 2
ra
Radiated emission test
Mode 3
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B)
Mode 4
FULL SYSTEM (CPT-1000) (PoE)
Mode 5
Mode 6
Mode 7
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1)
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:ADP-18TB A)
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (PoE)
Harmonic current emissions & Voltage changes, voltage fluctuations and flicker test
Final Test Mode
Mode 1
Mode 2
Description
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter :
FSP060-DBAB1)
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter :
ADP-18TB A)
Mode 3
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B)
Mode 4
FULL SYSTEM (CPT-1000) (PoE)
Mode 5
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1)
Report No.: NEI-EMC-1-1311149
Page 14 of 170
RV-0000000
Neutron Engineering Inc.
Mode 6
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:ADP-18TB A)
Mode 7
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (PoE)
Immunity tests
Final Test Mode
Mode 1
Mode 2
Description
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter :
FSP060-DBAB1)
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter :
ADP-18TB A)
Mode 3
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B)
Mode 4
FULL SYSTEM (CPT-1000) (PoE)
Mode 5
Mode 6
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (PoE)
D
ra
ft
Mode 7
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1)
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:ADP-18TB A)
Report No.: NEI-EMC-1-1311149
Page 15 of 170
Neutron Engineering Inc.
RV-0000000
3.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED
D
ra
ft
Mode 1 / Mode 2
Report No.: NEI-EMC-1-1311149
Page 16 of 170
RV-0000000
Neutron Engineering Inc.
Mode 3 / Mode 4
C-1
C-8
C-12
E-8
Modem
C-4
E-3
DVD PLAYER
C-5
E-5
Mouse
D
ra
ft
E-4
Keyboard
C-1 RJ-45 Cable
C-3 Video Cable
C-4 USB Cable
C-5 USB Cable
C-8 RS-232 Cable
C-12 Power Cable*9
C-3
E-12
Mico
SD
E-1
EUT
Remote
System
Report No.: NEI-EMC-1-1311149
Page 17 of 170
Neutron Engineering Inc.
RV-0000000
D
ra
ft
Mode 5 / Mode 6 / Mode 7
Report No.: NEI-EMC-1-1311149
Page 18 of 170
RV-0000000
Neutron Engineering Inc.
3.4 DESCRIPTION OF SUPPORT UNITS
The EUT has been tested as an independent unit together with other necessary accessories or
support units. The following support units or accessories were used to form a representative test
configuration during the tests.
Item
Equipment
Brand
E-1
IPC
VIA
E-2
24” LCD Monitor
E-3
Series No.
Note
N/A
N/A
EUT
DOC
071863-11
CD/DVD Player
SONY
DVP-NS975V
N/A
E-4
USB K/B
DELL
L50U
DOC
E-5
USB Mouse
DELL
MS111-L
DOC
2030851 14W
CN-0H9F99-65890
-17P-06WP-A01
CN-09RRC7-44
751-17J-OH1F
CJ-323
N/A
N/A
HV04T
DOC
95NY781
DM-1414V
WDBACW00
10HBK-SESN
VCVRA-1004
DOC
8041708
DOC
WCAV5J749731
DELL
U2410f
DOC
Sandisk
SDSDQ-512
DOC
E-7
E-8
E-9
E-10
Compact Earphone
CJ
Mic
USB Flash/MP3
DELL
Player
Modem
ACEEX
3.5” External Hard
WD
Drive
Printer
HP
24” LCD Monitor
E-12
Micro SD Card
D
E-11
ra
E-6
ft
FCC ID
DELL
Model/Type No.
AMOS-820;
CPT-1000;
AMOS-820-P
2408WFPb
Item
Shielded Type
Ferrite Core
Length
C-1
NO
NO
10M
C-2
YES
NO
1.8M
C-3
NO
NO
1.5M
C-4
YES
NO
1.7M
C-5
YES
NO
1.7M
C-6
NO
NO
1.8M
C-7
NO
NO
1.7M
C-8
YES
NO
1.7M
C-9
YES
NO
1.2M
C-10
YES
NO
1.7M
C-11
YES
NO
1.7M
C-12
NO
NO
1M
DOC
CN17511HHK
CN-OJ257M-72
872-09J-067L
N/A
Note
Note:
(1) The support equipment was authorized by Declaration of Conformity (DOC).
Report No.: NEI-EMC-1-1311149
Page 19 of 170
RV-0000000
Neutron Engineering Inc.
4. EMC EMISSION TEST
4.1 CONDUCTED EMISSION TEST
4.1.1 LIMITS (FREQUENCY RANGE 150 KHZ-30MHZ)
Class A (dBuV)
Class B (dBuV)
FREQUENCY
(MHz)
Quasi-peak
Average
Quasi-peak
Average
0.15 - 0.5
79.00
66.00
66 - 56 *
56 - 46 *
0.50 - 5.0
73.00
60.00
56.00
46.00
73.00
60.00
60.00
50.00
5.0 - 30.0
NOTE:
ft
(1) The tighter limit applies at the band edges.
(2) The limit of " * " marked band means the limitation decreases linearly with the logarithm of the
frequency in the range.
(3) The test result calculated as following:
Measurement Value = Reading Level + Correct Factor
Correct Factor = Insertion Loss + Cable Loss + Attenuator Factor(if use)
Margin Level = Measurement Value – Limit Value
Item Kind of Equipment
2
Test Cable
3
EMI Test Receiver
Measurement
Software
4
Manufacturer
Type No.
Serial No.
Calibrated until
R&S
ENV216
101051
Jun. 16, 2014
TIMES
CFD300-NL
C03
Jun. 16, 2014
R&S
ESCI
EZ_EMC
(Version NB-03A)
100080
Apr. 01, 2014
N/A
N/A
D
1
TWO-LINE
V-NETWORK
ra
4.1.2 MEASUREMENT INSTRUMENTS LIST
EZ
Remark: “N/A” denotes No Model Name, No Serial No. or No Calibration specified.
Report No.: NEI-EMC-1-1311149
Page 20 of 170
RV-0000000
Neutron Engineering Inc.
4.1.3 TEST PROCEDURE
a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected
to the power mains through a line impedance stabilization network (LISN). All other support
equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling
impedance for the measuring instrument.
b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
and forth in the center forming a bundle 30 to 40 cm long.
c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
cable may be terminated, if required, using the correct terminating impedance. The overall
length shall not exceed 1 m.
d. LISN at least 80 cm from nearest part of EUT chassis.
e. For the actual test configuration, please refer to the related Item –EUT Test Photos.
NOTE:
a. Reading in which marked as Peak, QP or AVG means measurements by using are Quasi-Peak or
Average Mode with Detector BW=9 kHz (6 dB Bandwidth).
b. All readings are Peak Mode value unless otherwise stated QP or AVG in column of Note. If the
Peak or QP Mode Measured value compliance with the QP Limits and lower than AVG Limits, the
EUT shall be deemed to meet both QP & AVG Limits and then only Peak or QP Mode was
measured, but AVG Mode didn‘t perform.
ft
4.1.4 DEVIATION FROM TEST STANDARD
No deviation
ra
4.1.5 TEST SETUP
D
Vertical Reference Ground Plane
40 cm
EUT
Test Receiver
80 cm
LISN
Horizontal Reference Ground Plane
Report No.: NEI-EMC-1-1311149
Page 21 of 170
Neutron Engineering Inc.
RV-0000000
D
ra
ft
4.1.6 EUT OPERATING CONDITIONS
The EUT exercise program used during radiated and/or conducted emission measurement was
designed to exercise the various system components in a manner similar to a typical use. The
program contained on a PC hard disk and is auto-starting on power-up. Once loaded, the program
sequentially exercises each system component in turn.
As the keyboard and mouse are strictly input devices, no data is transmitted to (from) them during
test. They are, however, continuously scanned for data input activity.
Report No.: NEI-EMC-1-1311149
Page 22 of 170
Neutron Engineering Inc.
RV-0000000
4.1.7 TEST RESULTS
EUT
Temperature
Test Voltage
Test Mode
IPC
Model Name
AMOS-820
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : FSP060-DBAB1)
D
ra
ft
Phase: Line
Report No.: NEI-EMC-1-1311149
Page 23 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : FSP060-DBAB1)
D
ra
ft
Phase: Neutral
Report No.: NEI-EMC-1-1311149
Page 24 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : ADP-18TB A)
D
ra
ft
Phase: Line
Report No.: NEI-EMC-1-1311149
Page 25 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : ADP-18TB A)
D
ra
ft
Phase: Neutral
Report No.: NEI-EMC-1-1311149
Page 26 of 170
RV-0000000
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
IPC
Model Name
24°C
Relative Humidity
AC 230V/50Hz
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B)
CPT-1000
48%
D
ra
ft
Phase: Line
Report No.: NEI-EMC-1-1311149
Page 27 of 170
RV-0000000
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
IPC
Model Name
24°C
Relative Humidity
AC 230V/50Hz
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B)
CPT-1000
48%
D
ra
ft
Phase: Neutral
Report No.: NEI-EMC-1-1311149
Page 28 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820-P
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1)
D
ra
ft
Phase: Line
Report No.: NEI-EMC-1-1311149
Page 29 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820-P
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1)
D
ra
ft
Phase: Neutral
Report No.: NEI-EMC-1-1311149
Page 30 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820-P
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:ADP-18TB A)
D
ra
ft
Phase: Line
Report No.: NEI-EMC-1-1311149
Page 31 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820-P
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:ADP-18TB A)
D
ra
ft
Phase: Neutral
Report No.: NEI-EMC-1-1311149
Page 32 of 170
RV-0000000
Neutron Engineering Inc.
4.2 CONDUCTED EMISSION AT TELECOMMUNICATION PORTS TEST
4.2.1 LIMITS
Voltage Limit:
Class A (dBuV)
FREQUENCY ( MHz)
Class B (dBuV)
Quasi-peak
Average
Quasi-peak
Average
0.15 -0.5
97-87*
84-74*
84-74*
74-64*
0.5 -30.0
87
74
74
64
Current Limit:
Class A (dBuA)
FREQUENCY ( MHz)
Class B (dBuA)
Quasi-peak
Average
Quasi-peak
Average
0.15 -0.5
53-43*
40-30*
40-30*
30-20*
0.5 -30.0
43
30
30
20
NOTE:
ra
ft
(1) The tighter limit applies at the band edges.
(2) The limit of " * " marked band means the limitation decreases linearly with the logarithm of the
frequency in the range.
(3) The test result calculated as following:
Measurement Value = Reading Level + Correct Factor
Correct Factor = Insertion Loss + Cable Loss + Attenuator Factor(if use)
Margin Level = Measurement Value – Limit Value
4.2.2 MEASUREMENT INSTRUMENTS LIST
Type No.
Serial No.
Calibrated until
R&S
ENV216
101051
Jun. 16, 2014
Test Cable
TIMES
CFD300-NL
C03
Jun. 16, 2014
EMI Test Receiver
Measurement
Software
R&S
ESCI
EZ_EMC
(Version NB-03A)
100080
Apr. 01, 2014
N/A
N/A
1
TWO-LINE
V-NETWORK
2
3
4
Manufacturer
D
Item Kind of Equipment
EZ
5
50Ω BNC TYPE
Terminator
N/A
N/A
04
Jul. 04, 2014
6
ISN
FCC
F-070306-1057-1-09
100363
Jun. 16, 2014
Remark: “N/A” denotes No Model Name, No Serial No. or No Calibration specified.
Report No.: NEI-EMC-1-1311149
Page 33 of 170
Neutron Engineering Inc.
RV-0000000
ft
4.2.3 TEST PROCEDURE
a. The EUT was placed 0.4 meters from the horizontal ground plane with EUT being connected
to the power mains through a line impedance stabilization network (LISN). All other support
equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling
impedance for the measuring instrument.
b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
and forth in the center forming a bundle 30 to 40 cm long.
c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
cable may be terminated, if required, using the correct terminating impedance. The overall
length shall not exceed 1 m.
d. ISN at least 80 cm from nearest part of EUT chassis.
e. The communication function of EUT was executed and ISN was connected between EUT and
associated equipment and the ISN was connected directly to reference ground plane.
f. For the actual test configuration, please refer to the related Item –EUT Test Photos.
NOTE:
a. Reading in which marked as Peak, QP or AVG means measurements by using are Quasi-Peak or
Average Mode with Detector BW=9 kHz (6 dB Bandwidth).
b. All readings are Peak Mode value unless otherwise stated QP or AVG in column of Note. If the
Peak or QP Mode Measured value compliance with the QP Limits and lower than AVG Limits, the
EUT shall be deemed to meet both QP & AVG Limits and then only Peak or QP Mode was
measured, but AVG Mode didn‘t perform.
D
4.2.5 TEST SETUP
ra
4.2.4 DEVIATION FROM TEST STANDARD
No deviation
4.2.6 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 4.1.6 Unless otherwise a special
operating condition is specified in the follows during the testing.
Report No.: NEI-EMC-1-1311149
Page 34 of 170
Neutron Engineering Inc.
RV-0000000
4.2.7 TEST RESULTS
EUT
Temperature
Test Voltage
D
ra
ft
Test Mode
IPC
Model Name
AMOS-820
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : FSP060-DBAB1)
(ETHERNET 1G-1G)
Report No.: NEI-EMC-1-1311149
Page 35 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
IPC
Model Name
AMOS-820
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : FSP060-DBAB1)
(ETHERNET 100M-100M)
D
ra
ft
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 36 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
IPC
Model Name
AMOS-820
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : FSP060-DBAB1)
(ETHERNET 10M-10M)
D
ra
ft
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 37 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
IPC
Model Name
AMOS-820
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : ADP-18TB A)
(ETHERNET 1G-1G)
D
ra
ft
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 38 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
IPC
Model Name
AMOS-820
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : ADP-18TB A)
(ETHERNET 100M-100M)
D
ra
ft
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 39 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
IPC
Model Name
AMOS-820
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : ADP-18TB A)
(ETHERNET 10M-10M)
D
ra
ft
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 40 of 170
Neutron Engineering Inc.
IPC
Model Name
CPT-1000
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B) (ETHERNET 1G-1G)
D
ra
ft
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 41 of 170
Neutron Engineering Inc.
IPC
Model Name
CPT-1000
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B) (ETHERNET 100M-100M)
D
ra
ft
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 42 of 170
Neutron Engineering Inc.
IPC
Model Name
CPT-1000
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B) (ETHERNET 10M-10M)
D
ra
ft
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 43 of 170
Neutron Engineering Inc.
IPC
Model Name
CPT-1000
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM (CPT-1000) (PoE) (ETHERNET 100M-100M)
D
ra
ft
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 44 of 170
Neutron Engineering Inc.
IPC
Model Name
CPT-1000
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM (CPT-1000) (PoE) (ETHERNET 10M-10M)
D
ra
ft
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 45 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
IPC
Model Name
AMOS-820-P
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1) (ETHERNET 1G-1G)
D
ra
ft
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 46 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
IPC
Model Name
AMOS-820-P
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1) (ETHERNET 100M-100M)
D
ra
ft
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 47 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
IPC
Model Name
AMOS-820-P
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1) (ETHERNET 10M-10M)
D
ra
ft
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 48 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
IPC
Model Name
AMOS-820-P
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:ADP-18TB A)
(ETHERNET 1G-1G)
D
ra
ft
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 49 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
IPC
Model Name
AMOS-820-P
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:ADP-18TB A)
(ETHERNET 100M-100M)
D
ra
ft
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 50 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
IPC
Model Name
AMOS-820-P
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:ADP-18TB A)
(ETHERNET 10M-10M)
D
ra
ft
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 51 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
IPC
Model Name
AMOS-820-P
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (PoE) (ETHERNET
100M-100M)
D
ra
ft
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 52 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
IPC
Model Name
AMOS-820-P
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (PoE) (ETHERNET
10M-10M)
D
ra
ft
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 53 of 170
RV-0000000
Neutron Engineering Inc.
4.3 RADIATED EMISSION TEST
4.3.1 LIMITS
Below 1 GHz
FREQUENCY
(MHz)
30 - 230
230 - 1000
Class A (at 10m)
dBuV/m
40
47
Class B (at 10m)
dBuV/m
30
37
NOTE:
(1) The limit for radiated test was performed according to as following:
EN 55022.
(2) The tighter limit applies at the band edges.
(3) Emission level (dBuV/m) = 20log Emission level (uV/m).
(4) The test result calculated as following:
Measurement Value = Reading Level + Correct Factor
Correct Factor = Antenna Factor + Cable Loss - Amplifier Gain(if use)
Margin Level = Measurement Value - Limit Value
Above 1 GHz
FREQUENCY
(MHz)
1000 - 3000
3000 - 6000
ft
Class B (dBuV/m) (at 3m)
PEAK
AVERAGE
70
50
74
54
ra
NOTE:
Class A (dBuV/m) (at 3m)
PEAK
AVERAGE
76
56
80
60
D
(1) The limit for radiated test was performed according to as following:
EN 55022.
(2) The tighter limit applies at the band edges.
(3) Emission level (dBuV/m) = 20log Emission level (uV/m).
3m Emission level = 10m Emission level + 20log(10m/3m).
(4) The test result calculated as following:
Measurement Value = Reading Level + Correct Factor
Correct Factor = Antenna Factor + Cable Loss - Amplifier Gain(if use)
Margin Level = Measurement Value - Limit Value
FREQUENCY RANGE OF RADIATED MEASUREMENT (FOR UNINTENTIONAL RADIATORS)
Highest frequency generated or Upper
frequency of measurement used in the device
Range (MHz)
or on which the device operates or tunes
(MHz)
Below 108
1000
108 - 500
2000
500 - 1000
5000
5th harmonic of the highest frequency or 6
Above 1000
GHz, whichever is lower
Report No.: NEI-EMC-1-1311149
Page 54 of 170
RV-0000000
Neutron Engineering Inc.
4.3.2 MEASUREMENT INSTRUMENTS LIST
Below 1 GHz:
Item Kind of Equipment Manufacturer
1 Log-Bicon Antenna Schwarzbeck
Type No.
VULB 9160
Serial No.
3173
Calibrated until
Nov. 28, 2014
Pre-Amplifier
Anritsu
MH648A
M98457
Jun. 02, 2014
3
Test Cable
TIMES
LMR-400
10M-OS01
Jun. 02, 2014
4
Test Cable
TIMES
LMR-400
OS02
Jun. 02, 2014
5
EMI Test Receiver
R&S
ESCI
100082
Mar. 21, 2014
6
System Controller
(OS02)
CT
SC100
N/A
N/A
Chance Most
CMTB-1.5
EZ_EMC
(Version NB-02A)
N/A
N/A
N/A
N/A
Type No.
BBHA 9120 D
Serial No.
9120D-325
Calibrated until
Jun. 15, 2014
8449B
3008A01714
Apr. 16, 2014
27478 LL142
1M
May. 13, 2014
S104-SMAP-1
10M
May. 15, 2014
27478 LL142
3M
May. 13, 2014
FSP-40
EZ_EMC
(Version NB-03A)
100129
Oct. 01, 2014
N/A
N/A
7
8
Turn Table
Measurement
Software
EZ
Above 1 GHz:
Item Kind of Equipment Manufacturer
1 Horn Antenna (1G) Schwarzbeck
4
5
6
7
Agilent
HARBOUR
Microflex Cable
INDUSTRIES
Microflex Cable
AISI
HARBOUR
Microflex Cable
INDUSTRIES
Spectrum Analyzer
R&S
Measurement
EZ
Software
ra
3
Pre_Amplifier
D
2
ft
2
Remark: “N/A” denotes No Model Name, No Serial No. or No Calibration specified.
Report No.: NEI-EMC-1-1311149
Page 55 of 170
Neutron Engineering Inc.
RV-0000000
4.3.3 TEST PROCEDURE
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3m or 10
meter open area test site. The table was rotated 360 degrees to determine the position of the
highest radiation.
b. The height of the equipment or of the substitution antenna shall be 0.8 m; the height of the test
antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the
antenna are set to make the measurement.
c. The initial step in collecting radiated emission data is a spectrum analyzer peak detector mode
pre-scanning the measurement frequency range. Significant peaks are then marked and then
Quasi Peak detector mode re-measured.
d. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the
EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement
performed.
e. For the actual test configuration, please refer to the related Item –EUT Test Photos.
NOTE: (Below 1 GHz)
a. Reading in which marked as QP or Peak means measurements by using are Quasi-Peak Mode
with Detector BW=120 kHz.
b. All readings are Peak unless otherwise stated QP in column of Note. Peak denotes that the Peak
reading compliance with the QP Limits and then QP Mode measurement didn‘t perform.
D
ra
ft
NOTE: (Above 1 GHz)
a. Reading in which marked as Peak means measurements by using are Peak Mode with
instrument setting in RBW= 1 MHz, VBW= 1 MHz.
Reading in which marked as AV means measurements by using are Average Mode with
instrument setting in RBW= 1 MHz, VBW= 10 Hz.
b. All readings are Peak Mode value unless otherwise stated AVG in column of Note. If the Peak
Mode Measured value compliance with the Peak Limits and lower than AVG Limits, the EUT shall
be deemed to meet both Peak & AVG Limits and then only Peak Mode was measured, but AVG
Mode didn‘t perform.
Report No.: NEI-EMC-1-1311149
Page 56 of 170
Neutron Engineering Inc.
RV-0000000
4.3.4 DEVIATION FROM TEST STANDARD
No deviation
4.3.5 TEST SETUP
ft
Below 1 GHz
D
ra
Above 1 GHz
4.3.6 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 4.1.6 Unless otherwise a special
operating condition is specified in the follows during the testing.
Report No.: NEI-EMC-1-1311149
Page 57 of 170
Neutron Engineering Inc.
RV-0000000
4.3.7 TEST RESULTS-BELOW 1 GHZ
EUT
Temperature
Test Voltage
Test Mode
IPC
Model Name
AMOS-820
25°C
Relative Humidity
76%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : FSP060-DBAB1)
D
ra
ft
Polarization: Vertical
Report No.: NEI-EMC-1-1311149
Page 58 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820
25°C
Relative Humidity
76%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : FSP060-DBAB1)
D
ra
ft
Polarization: Horizontal
Report No.: NEI-EMC-1-1311149
Page 59 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820
25°C
Relative Humidity
76%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : ADP-18TB A)
D
ra
ft
Polarization: Vertical
Report No.: NEI-EMC-1-1311149
Page 60 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820
25°C
Relative Humidity
76%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : ADP-18TB A)
D
ra
ft
Polarization: Horizontal
Report No.: NEI-EMC-1-1311149
Page 61 of 170
RV-0000000
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
IPC
Model Name
25°C
Relative Humidity
AC 230V/50Hz
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B)
CPT-1000
76%
D
ra
ft
Polarization: Vertical
Report No.: NEI-EMC-1-1311149
Page 62 of 170
RV-0000000
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
IPC
Model Name
25°C
Relative Humidity
AC 230V/50Hz
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B)
CPT-1000
76%
D
ra
ft
Polarization: Horizontal
Report No.: NEI-EMC-1-1311149
Page 63 of 170
RV-0000000
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
IPC
Model Name
25°C
Relative Humidity
DC 48V
FULL SYSTEM (CPT-1000) (PoE)
CPT-1000
76%
D
ra
ft
Polarization: Vertical
Report No.: NEI-EMC-1-1311149
Page 64 of 170
RV-0000000
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
IPC
Model Name
25°C
Relative Humidity
DC 48V
FULL SYSTEM (CPT-1000) (PoE)
CPT-1000
76%
D
ra
ft
Polarization: Horizontal
Report No.: NEI-EMC-1-1311149
Page 65 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820-P
25°C
Relative Humidity
76%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1)
D
ra
ft
Polarization: Vertical
Report No.: NEI-EMC-1-1311149
Page 66 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820-P
25°C
Relative Humidity
76%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1)
D
ra
ft
Polarization: Horizontal
Report No.: NEI-EMC-1-1311149
Page 67 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820-P
25°C
Relative Humidity
76%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:ADP-18TB A)
D
ra
ft
Polarization: Vertical
Report No.: NEI-EMC-1-1311149
Page 68 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820-P
25°C
Relative Humidity
76%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:ADP-18TB A)
D
ra
ft
Polarization: Horizontal
Report No.: NEI-EMC-1-1311149
Page 69 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820-P
25°C
Relative Humidity
76%
DC 48V
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (PoE)
D
ra
ft
Polarization: Vertical
Report No.: NEI-EMC-1-1311149
Page 70 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820-P
25°C
Relative Humidity
76%
DC 48V
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (PoE)
D
ra
ft
Polarization: Horizontal
Report No.: NEI-EMC-1-1311149
Page 71 of 170
Neutron Engineering Inc.
RV-0000000
4.3.8 TEST RESULTS-ABOVE 1 GHZ
EUT
Temperature
Test Voltage
Test Mode
IPC
Model Name
AMOS-820
26°C
Relative Humidity
60%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : FSP060-DBAB1)
D
ra
ft
Polarization: Vertical
Report No.: NEI-EMC-1-1311149
Page 72 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820
26°C
Relative Humidity
60%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : FSP060-DBAB1)
D
ra
ft
Polarization: Horizontal
Report No.: NEI-EMC-1-1311149
Page 73 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820
26°C
Relative Humidity
60%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : ADP-18TB A)
D
ra
ft
Polarization: Vertical
Report No.: NEI-EMC-1-1311149
Page 74 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820
26°C
Relative Humidity
60%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : ADP-18TB A)
D
ra
ft
Polarization: Horizontal
Report No.: NEI-EMC-1-1311149
Page 75 of 170
RV-0000000
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
IPC
Model Name
26°C
Relative Humidity
AC 230V/50Hz
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B)
CPT-1000
60%
D
ra
ft
Polarization: Vertical
Report No.: NEI-EMC-1-1311149
Page 76 of 170
RV-0000000
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
IPC
Model Name
26°C
Relative Humidity
AC 230V/50Hz
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B)
CPT-1000
60%
D
ra
ft
Polarization: Horizontal
Report No.: NEI-EMC-1-1311149
Page 77 of 170
RV-0000000
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
IPC
Model Name
26°C
Relative Humidity
DC 48V
FULL SYSTEM (CPT-1000) (PoE)
CPT-1000
60%
D
ra
ft
Polarization: Vertical
Report No.: NEI-EMC-1-1311149
Page 78 of 170
RV-0000000
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
IPC
Model Name
26°C
Relative Humidity
DC 48V
FULL SYSTEM (CPT-1000) (PoE)
CPT-1000
60%
D
ra
ft
Polarization: Horizontal
Report No.: NEI-EMC-1-1311149
Page 79 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820-P
26°C
Relative Humidity
60%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1)
D
ra
ft
Polarization: Vertical
Report No.: NEI-EMC-1-1311149
Page 80 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820-P
26°C
Relative Humidity
60%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1)
D
ra
ft
Polarization: Horizontal
Report No.: NEI-EMC-1-1311149
Page 81 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820-P
26°C
Relative Humidity
60%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:ADP-18TB A)
D
ra
ft
Polarization: Vertical
Report No.: NEI-EMC-1-1311149
Page 82 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820-P
26°C
Relative Humidity
60%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:ADP-18TB A)
D
ra
ft
Polarization: Horizontal
Report No.: NEI-EMC-1-1311149
Page 83 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820-P
26°C
Relative Humidity
60%
DC 48V
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (PoE)
D
ra
ft
Polarization: Vertical
Report No.: NEI-EMC-1-1311149
Page 84 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
IPC
Model Name
AMOS-820-P
26°C
Relative Humidity
60%
DC 48V
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (PoE)
D
ra
ft
Polarization: Horizontal
Report No.: NEI-EMC-1-1311149
Page 85 of 170
RV-0000000
Neutron Engineering Inc.
4.4 HARMONIC CURRENT EMISSIONS TEST
4.4.1 LIMITS
Equipment
Category
ra
ft
Class A
EN 61000-3-2/IEC 61000-3-2
Max.
Harmonic Permissible
Harmonic
Max. Permissible
Equipment
Order
Harmonic
Order
Harmonic Current
Category
Current
n
A
n
A
mA/w
Odd Harmonics
Odd Harmonics only
3
2.30
3
2.30
3.4
5
1.14
5
1.14
1.9
7
0.77
7
0.77
1.0
Class D
9
0.40
9
0.40
0.5
11
0.33
11
0.33
0.35
13
0.21
13
0.21
0.30
0.15
x
15/n
0.15
x
15/n
3.85/n
15≤n≤39
15≤n≤39
Even Harmonics
2
1.08
4
0.43
6
0.30
8≤n≤40 0.23 x 8/n
4.4.2 MEASUREMENT INSTRUMENTS LIST
Item Kind of Equipment
1 Harmonic & Flicker
3
Power Source
Measurement
Software
Type No.
PACS-1
Serial No.
72345
Calibrated until
Apr. 02, 2014
California
3001iX
CTS 3.0
(Version 3.2.0.31)
56310
Apr. 02, 2014
CIC632
N/A
D
2
Manufacturer
California
California
Remark: “N/A” denotes No Model Name, No Serial No. or No Calibration specified.
Report No.: NEI-EMC-1-1311149
Page 86 of 170
RV-0000000
Neutron Engineering Inc.
4.4.3 TEST PROCEDURE
a. The EUT was placed on the top of a wooden table 0.8 meters above the ground and operated
to produce the maximum harmonic components under normal operating conditions.
b. The classification of EUT is according to of EN 61000-3-2/IEC 61000-3-2.The EUT is classified
as follows:
Class A: Balanced three-phase equipment, Household appliances excluding equipment as
Class D, Tools excluding portable tools, Dimmers for incandescent lamps, audio
equipment, equipment not specified in one of the three other classes.
Class B: Portable tools. Portable tools; Arc welding equipment which is not professional
equipment.
Class C: Lighting equipment.
Class D: Equipment having a specified power less than or equal to600 W of the following
types: Personal computers and personal computer monitors and television
receivers.
c. The correspondent test program of test instrument to measure the current harmonics
emanated from EUT is chosen. The measure time shall be not less than the time necessary for
the EUT to be exercised.
ft
4.4.4 DEVIATION FROM TEST STANDARD
No deviation
Power Analyzer &
Power Source
D
To AC Mains
Power Supply
ra
4.4.5 TEST SETUP
Voltage Supply
To EUT
EUT
Non-Metallic Table
4.4.6 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 4.1.6 Unless otherwise a special
operating condition is specified in the follows during the testing.
Report No.: NEI-EMC-1-1311149
Page 87 of 170
RV-0000000
Neutron Engineering Inc.
4.4.7 TEST RESULTS
Harmonics – Class-D per Ed. 3.2 (2009) (Run time) incl. inter-harmonics
EUT
Temperature
Test Voltage
D
ra
ft
Test Mode
IPC
Model Name
AMOS-820
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter :
FSP060-DBAB1)
Report No.: NEI-EMC-1-1311149
Page 88 of 170
Neutron Engineering Inc.
RV-0000000
Current Test Result Summary (Run time)
EUT
Temperature
Test Voltage
D
ra
ft
Test Mode:
IPC
Model Name
AMOS-820
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter :
FSP060-DBAB1)
Report No.: NEI-EMC-1-1311149
Page 89 of 170
Neutron Engineering Inc.
RV-0000000
Voltage Source Verification Data (Run time)
EUT
Temperature
Test Voltage
D
ra
ft
Test Mode:
IPC
Model Name
AMOS-820
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter :
FSP060-DBAB1)
Report No.: NEI-EMC-1-1311149
Page 90 of 170
RV-0000000
Neutron Engineering Inc.
Harmonics – Class-D per Ed. 3.2 (2009) (Run time) incl. inter-harmonics
IPC
Model Name
AMOS-820
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : ADP-18TB A)
D
ra
ft
EUT
Temperature
Test Voltage
Test Mode
Report No.: NEI-EMC-1-1311149
Page 91 of 170
Neutron Engineering Inc.
RV-0000000
Current Test Result Summary (Run time)
IPC
Model Name
AMOS-820
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : ADP-18TB A)
D
ra
ft
EUT
Temperature
Test Voltage
Test Mode:
Report No.: NEI-EMC-1-1311149
Page 92 of 170
Neutron Engineering Inc.
RV-0000000
Voltage Source Verification Data (Run time)
IPC
Model Name
AMOS-820
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : ADP-18TB A)
D
ra
ft
EUT
Temperature
Test Voltage
Test Mode:
Report No.: NEI-EMC-1-1311149
Page 93 of 170
RV-0000000
Neutron Engineering Inc.
Harmonics – Class-D per Ed. 3.2 (2009) (Run time) incl. inter-harmonics
IPC
Model Name
CPT-1000
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B)
D
ra
ft
EUT
Temperature
Test Voltage
Test Mode
Report No.: NEI-EMC-1-1311149
Page 94 of 170
Neutron Engineering Inc.
RV-0000000
Current Test Result Summary (Run time)
IPC
Model Name
CPT-1000
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B)
D
ra
ft
EUT
Temperature
Test Voltage
Test Mode:
Report No.: NEI-EMC-1-1311149
Page 95 of 170
Neutron Engineering Inc.
RV-0000000
Voltage Source Verification Data (Run time)
IPC
Model Name
CPT-1000
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B)
D
ra
ft
EUT
Temperature
Test Voltage
Test Mode:
Report No.: NEI-EMC-1-1311149
Page 96 of 170
RV-0000000
Neutron Engineering Inc.
Harmonics – Class-D per Ed. 3.2 (2009) (Run time) incl. inter-harmonics
EUT
Temperature
Test Voltage
D
ra
ft
Test Mode
IPC
Model Name
AMOS-820-P
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1)
Report No.: NEI-EMC-1-1311149
Page 97 of 170
Neutron Engineering Inc.
RV-0000000
Current Test Result Summary (Run time)
EUT
Temperature
Test Voltage
D
ra
ft
Test Mode:
IPC
Model Name
AMOS-820-P
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1)
Report No.: NEI-EMC-1-1311149
Page 98 of 170
Neutron Engineering Inc.
RV-0000000
Voltage Source Verification Data (Run time)
EUT
Temperature
Test Voltage
D
ra
ft
Test Mode:
IPC
Model Name
AMOS-820-P
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1)
Report No.: NEI-EMC-1-1311149
Page 99 of 170
RV-0000000
Neutron Engineering Inc.
Harmonics – Class-D per Ed. 3.2 (2009) (Run time) incl. inter-harmonics
EUT
Temperature
Test Voltage
D
ra
ft
Test Mode
IPC
Model Name
AMOS-820-P
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:ADP-18TB
A)
Report No.: NEI-EMC-1-1311149
Page 100 of 170
Neutron Engineering Inc.
RV-0000000
Current Test Result Summary (Run time)
EUT
Temperature
Test Voltage
D
ra
ft
Test Mode:
IPC
Model Name
AMOS-820-P
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:ADP-18TB
A)
Report No.: NEI-EMC-1-1311149
Page 101 of 170
Neutron Engineering Inc.
RV-0000000
Voltage Source Verification Data (Run time)
EUT
Temperature
Test Voltage
D
ra
ft
Test Mode:
IPC
Model Name
AMOS-820-P
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:ADP-18TB
A)
Report No.: NEI-EMC-1-1311149
Page 102 of 170
RV-0000000
Neutron Engineering Inc.
4.5 VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER TEST
4.5.1 LIMITS
Limits
IEC/EN 61000-3-3
≤ 1.0, Tp= 10 min.
≤ 0.65, Tp=2 hr.
≤ 3.3%
≤ 4%
≤ 3.3% for > 500 ms
Tests
Pst
Plt
dc
dmax
d (t)
Descriptions
Short Term Flicker Indicator
Long Term Flicker Indicator
Relative Steady-State V-Chang
Maximum Relative V-change
Relative V-change characteristic
4.5.2 MEASUREMENT INSTRUMENTS LIST
2
3
Power Source
Measurement
Software
Manufacturer
California
Type No.
PACS-1
Serial No.
72345
Calibrated until
Apr. 02, 2014
California
3001iX
CTS 3.0
(Version 3.2.0.31)
56310
Apr. 02, 2014
California
ft
Item Kind of Equipment
1 Harmonic & Flicker
CIC632
N/A
ra
Remark: “N/A” denotes No Model Name, No Serial No. or No Calibration specified.
D
4.5.3 TEST PROCEDURE
a. Tests was performed according to the Test Conditions/Assessment of Voltage Fluctuations
specified in EN 61000-3-3/IEC 61000-3-3 depend on which standard adopted for compliance
measurement.
b. All types of harmonic current and/or voltage fluctuation in this report are assessed by direct
measurement using flicker-meter.
4.5.4 DEVIATION FROM TEST STANDARD
No deviation
Report No.: NEI-EMC-1-1311149
Page 103 of 170
RV-0000000
Neutron Engineering Inc.
4.5.5 TESTSETUP
Voltage Supply
To EUT
To AC Mains
Power Supply
Power Analyzer &
Power Source
EUT
ft
Non-Metallic Table
D
ra
4.5.6 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 4.1.6 Unless otherwise a special
operating condition is specified in the follows during the testing.
Report No.: NEI-EMC-1-1311149
Page 104 of 170
Neutron Engineering Inc.
RV-0000000
4.5.7 TEST RESULTS
EUT
Temperature
Test Voltage
D
ra
ft
Test Mode
IPC
Model Name
AMOS-820
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter :
FSP060-DBAB1)
Report No.: NEI-EMC-1-1311149
Page 105 of 170
Neutron Engineering Inc.
IPC
Model Name
AMOS-820
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : ADP-18TB A)
D
ra
ft
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 106 of 170
Neutron Engineering Inc.
IPC
Model Name
CPT-1000
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B)
D
ra
ft
EUT
Temperature
Test Voltage
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 107 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
IPC
Model Name
AMOS-820-P
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P)
(ADAPTER:FSP060-DBAB1)
D
ra
ft
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 108 of 170
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
IPC
Model Name
AMOS-820-P
24°C
Relative Humidity
48%
AC 230V/50Hz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:ADP-18TB
A)
D
ra
ft
Test Mode
RV-0000000
Report No.: NEI-EMC-1-1311149
Page 109 of 170
Neutron Engineering Inc.
RV-0000000
5. EMC IMMUNITY TEST - EN 55024
5.1 STANDARD COMPLIANCE/SERVRITY LEVEL/CRITERIA
TEST SPECIFICATION
Test Mode
Performance
Level
Test Ports
Criterion
8 kV air discharge
Direct Mode
B
Electrostatic discharge immunity 4 kV contact discharge
IEC/EN 61000-4-2
4 kV HCP discharge
Indirect Mode
B
4 kV VCP discharge
Radiated, radio-frequency,
80 MHz to 1000 MHz
Enclosure
A
electromagnetic field immunity 3 V/m(rms), 1 kHz, 80%,
IEC/EN 61000-4-3
AM modulated
1.0kV(peak)
Power Supply
5/50ns Tr/Th
B
Port
Electrical fast transient/burst
5 kHz Repetition Freq.
immunity
CTL/Signal
0.5 kV(peak)
IEC/EN 61000-4-4
Data Line
B
5/50ns Tr/Th
Port
5 kHz Repetition Freq.
1 kV(5P/5N)
AC Power Port
B
1.2/50(8/20) Tr/Th μs
L-N
2 kV(5P/5N)
AC Power Port
B
1.2/50(8/20) Tr/Th μs
L-PE/N-PE
Surge immunity
IEC/EN 61000-4-5
0.5 kV(5P/5N)
DC Power Port
B
1.2/50(8/20) Tr/Th μs
1 kV(5P/5N)
Signal/TelecommuniC
10/700 or 1.2/50 Tr/Th μs
cation Ports
0.15 MHz to 80 MHz
3 V(rms), 1 kHz 80%,
CTL/Signal Port
A
AM Modulated
150Ω source impedance
0.15 MHz to 80 MHz
Immunity to conducted
3 V(rms), 1 kHz 80%,
disturbances, induced by
AC Power Port
A
AM Modulated
radio-frequency fields
IEC/EN 61000-4-6
150Ω source impedance
0.15 MHz to 80 MHz
3 V(rms), 1 kHz 80%,
DC Power Port
A
AM Modulated
150Ω source impedance
Power frequency magnetic field
immunity
50/60 Hz, 1 A/m
Enclosure
A
IEC/EN 61000-4-8
Voltage dips, short interruptions Voltage Dips>95%
B
and voltage variations immunity Voltage Dips 30%
AC Power Port
C
IEC/EN 61000-4-11
C
Voltage Interruptions>95%
D
ra
ft
Tests
Standard No.
Report No.: NEI-EMC-1-1311149
Page 110 of 170
Neutron Engineering Inc.
RV-0000000
5.2 GENERAL PERFORMANCE CRITERIA
According to EN55024 standard, the general performance criteria as following:
D
ra
ft
The equipment shall continue to operate as intended without operator
intervention. No degradation of performance or loss of function is allowed below
a performance level specified by the manufacturer when the equipment is used
as intended. The performance level may be replaced by a permissible loss of
performance.
Criterion A
If the minimum performance level or the permissible performance loss is not
specified by the manufacturer, then either of these may be derived from the
product description and documentation, and by what the user product
description and documentation, and by what the user may reasonably expect
from the equipment if used as intended.
After the test, the equipment shall continue to operate as intended without
operator
Intervention. No degradation of performance or loss of function is allowed, after
the application of the phenomenon below a performance level specified by the
manufacturer, when the equipment is used as intended. The performance level
may be replaced by a permissible loss of performance.
Criterion B
During the test, degradation of performance is allowed. However, no change of
operating state if stored data allowed to persist after the test. If the minimum
performance level (or the permissible performance loss ) is not specified by the
manufacturer, then either of these may be derived from the product description
and documentation, and by what the user may reasonably expect from the
equipment if used as intended.
Loss of function is allowed, provided the function is self-recoverable, or can be
restored by the operation of the controls by the user in accordance with the
Criterion C manufacturer’s instructions.
Functions, and/or information stored in non-volatile memory, or protected by a
battery backup, shall not be lost.
5.3 GENERAL PERFORMANCE CRITERIA TEST SETUP
The EUT tested system was configured as the statements of 4.1.6 Unless otherwise a special
operating condition is specified in the follows during the testing.
Report No.: NEI-EMC-1-1311149
Page 111 of 170
RV-0000000
Neutron Engineering Inc.
5.4 ELECTROSTATIC DISCHARGE IMMUNITY TEST (ESD)
5.4.1 TEST SPECIFICATION
Basic Standard
Discharge Impedance
Required Performance
Discharge Voltage
Polarity
Number of Discharge
Discharge Mode
Discharge Period
IEC/EN 61000-4-2
330 ohm / 150 pF
B
Air Discharge: 2 kV, 4 kV, 8 kV (Direct)
Contact Discharge: 2 kV, 4 kV (Direct/Indirect)
Positive & Negative
Air Discharge: min. 20 times at each test point
Contact Discharge: min. 200 times in total
Single Discharge
1 second minimum
5.4.2 MEASUREMENT INSTRUMENTS
Item Kind of Equipment
ESD Simulator
1
Manufacturer
TESEQ
Type No.
NSG 437
Serial No.
429
Calibrated until
May. 05, 2014
ft
Remark: “N/A” denotes No Model Name, No Serial No. or No Calibration specified.
D
ra
5.4.3 TEST PROCEDURE
The test generator necessary to perform direct and indirect application of discharges to the EUT in
the following manner:
a. Contact discharge was applied to conductive surfaces (Direct) and coupling planes (Indirect)
of the EUT.
During the test, it was performed with single discharges. For the single discharge time
between successive single discharges was at least 1 second. The EUT shall be exposed to at
least 200 discharges, 100 each at negative and positive polarity, at a minimum of four test
points. One of the test points shall be subjected to at least 50 indirect discharges to the center
of the front edge of the horizontal coupling plane. The remaining three test points shall each
receive at least 50 direct contact discharges.
If no direct contact test points are available, then at least 200 indirect discharges shall be
applied in the indirect mode. Test shall be performed at a maximum repetition rate of one
discharge per second.
Vertical Coupling Plane (VCP):
The coupling plane, of dimensions 0.5m x 0.5m, is placed parallel to, and positioned at a
distance 0.1m from, the EUT, with the Discharge Electrode touching the coupling plane.
The four faces of the EUT will be performed with electrostatic discharge.
Horizontal Coupling Plane (HCP):
The coupling plane is placed under to the EUT. The generator shall be positioned vertically at
a distance of 0.1m from the EUT, with the Discharge Electrode touching the coupling plane.
The four faces of the EUT will be performed with electrostatic discharge.
b. Air discharges at insulation surfaces of the EUT.
It was at least ten single discharges with positive and negative at the same selected point.
Report No.: NEI-EMC-1-1311149
Page 112 of 170
RV-0000000
Neutron Engineering Inc.
5.4.4 DEVIATION FROM TEST STANDARD
No deviation
5.4.5 TEST SETUP
Nearest Wall
10 cm
1m
VCP (50 cm x 50 cm)
ESD Generator
ESD Generator
Discharge Return
Cable to GRP
Discharge Return
Cable to GRP
To AC Main
Isolation Support
(0.5mm)
EUT
HCP
(1.6m x 0.8m)
Non-Conductive Table
470 KΩ
470 KΩ
ft
80 cm
Note:
ra
Ground Reference Plane (GRP) Bonded to PE
D
TABLE-TOP EQUIPMENT
The configuration consisted of a wooden table 0.8 meters high standing on the Ground Reference
Plane. The GRP consisted of a sheet of aluminum at least 0.25mm thick, and 2.5 meters square
connected to the protective grounding system. A Horizontal Coupling Plane (1.6m x 0.8m) was
placed on the table and attached to the GRP by means of a cable with 940k total impedance. The
equipment under test was installed in a representative system as described in EN 61000-4-2/
IEC 61000-4-2, and its cables were placed on the HCP and isolated by an insulating support of
0.5mm thickness. A distance of1-meter minimum was provided between the EUT and the walls of
the laboratory and any other metallic structure.
FLOOR-STANDING EQUIPMENT
The equipment under test was installed in a representative system as described in
EN 61000-4-2/IEC 61000-4-2, and its cables were isolated from the Ground Reference Plane by
an insulating support of0.1-meter thickness. The GRP consisted of a sheet of aluminum that is at
least 0.25mm thick, and 2.5meters square connected to the protective grounding system and
extended at least 0.5 meters from the EUT on all sides.
Report No.: NEI-EMC-1-1311149
Page 113 of 170
RV-0000000
Neutron Engineering Inc.
5.4.6 TEST RESULTS
Mode
2 kV
P
N
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
-
Air Discharge
4 kV
8 kV
P
N
P
N
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
A
PASS
D
Location
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
Criterion
Result
Judgment
Model Name
-- kV
P
N
-
P
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
2kV
N
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Report No.: NEI-EMC-1-1311149
Contact
4 kV
P
N
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
ft
Temperature
Pressure
Test Mode
AMOS-820; CPT-1000;
AMOS-820-P
24°C
Relative Humidity 48%
1023 hPa
Test Voltage
AC 230V/50Hz / DC 48V
Mode 1 / Mode 2 / Mode 3 / Mode 4 / Mode 5 / Mode 6 / Mode 7
IPC
ra
EUT
B
A
PASS
Discharge
-- kV
P
N
-
-- kV
P
N
-
Page 114 of 170
RV-0000000
Neutron Engineering Inc.
-- kV
P
N
-
P
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
2kV
N
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Report No.: NEI-EMC-1-1311149
Contact
4 kV
P
N
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
ft
2 kV
P
N
-
D
Location
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
Criterion
Result
Judgment
Air Discharge
4 kV
8 kV
P
N
P
N
B
A
PASS
ra
Mode
B
A
PASS
Discharge
-- kV
P
N
-
-- kV
P
N
-
Page 115 of 170
RV-0000000
Neutron Engineering Inc.
Location
1
2
3
4
Criterion
Result
Judgment
Note:
HCP Discharge
4 kV
-- kV
P
N
P
N
A
A
A
A
A
A
A
A
B
A
PASS
2 kV
P
N
A
A
A
A
A
A
A
A
-- kV
P
N
-
2kV
P
N
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
-- kV
P
N
-
2 kV
P
N
A
A
A
A
A
A
A
A
Contact
4 kV
P
N
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
A
PASS
ra
Mode
Air Discharge
4 kV
8 kV
P
N
P
N
B
A
PASS
D
Location
77
78
79
80
81
82
83
84
85
86
87
88
89
Criterion
Result
Judgment
2 kV
P
N
-
ft
Mode
Discharge
-- kV
P
N
-
VCP Discharge
4 kV
-- kV
P
N
P
N
A
A
A
A
A
A
A
A
B
A
PASS
-- kV
P
N
-
-- kV
P
N
-
1) P/N denotes the Positive/Negative polarity of the output voltage.
2) Test condition:
Direct/Indirect (HCP/VCP) discharges: Minimum 25 times (Positive/Negative) at each point.
Air discharges: Minimum 10 times (Positive/Negative) at each point.
3) Test location(s) in which discharge (Air and contact discharge) to be applied illustrated by photos
shown in next page(s)
4) The Indirect (HCP/VCP) discharges description of test point as following:
1. left side; 2.right side; 3.front side; 4.rear side.
5) N/A - denotes test is not applicable in this test report
6) Criterion A: No observation of any performance degradation.
7) Criterion B: Some degradation of performance is observed but the equipment continues to operate as
intended.
8) Criterion C: Loss of functionality, but self-recoverable by user, without loss of information or settings.
9) *: Specified by applicant.
Report No.: NEI-EMC-1-1311149
Page 116 of 170
Neutron Engineering Inc.
RV-0000000
D
ra
ft
PHOTO(S) SHOWN THE LOCATION(S) OF ESD EVALUATED
Report No.: NEI-EMC-1-1311149
Page 117 of 170
Neutron Engineering Inc.
RV-0000000
D
ra
ft
PHOTO(S) SHOWN THE LOCATION(S) OF ESD EVALUATED
Report No.: NEI-EMC-1-1311149
Page 118 of 170
Neutron Engineering Inc.
RV-0000000
D
ra
ft
PHOTO(S) SHOWN THE LOCATION(S) OF ESD EVALUATED
Report No.: NEI-EMC-1-1311149
Page 119 of 170
Neutron Engineering Inc.
RV-0000000
D
ra
ft
PHOTO(S) SHOWN THE LOCATION(S) OF ESD EVALUATED
Report No.: NEI-EMC-1-1311149
Page 120 of 170
Neutron Engineering Inc.
RV-0000000
D
ra
ft
PHOTO(S) SHOWN THE LOCATION(S) OF ESD EVALUATED
Report No.: NEI-EMC-1-1311149
Page 121 of 170
Neutron Engineering Inc.
RV-0000000
D
ra
ft
PHOTO(S) SHOWN THE LOCATION(S) OF ESD EVALUATED
Report No.: NEI-EMC-1-1311149
Page 122 of 170
Neutron Engineering Inc.
RV-0000000
D
ra
ft
PHOTO(S) SHOWN THE LOCATION(S) OF ESD EVALUATED
Report No.: NEI-EMC-1-1311149
Page 123 of 170
Neutron Engineering Inc.
RV-0000000
D
ra
ft
PHOTO(S) SHOWN THE LOCATION(S) OF ESD EVALUATED
Report No.: NEI-EMC-1-1311149
Page 124 of 170
RV-0000000
Neutron Engineering Inc.
5.5 RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST (RS)
5.5.1 TEST SPECIFICATION
Basic Standard
Required Performance
Frequency Range
Field Strength
Modulation
Frequency Step
Polarity of Antenna
Test Distance
Antenna Height
Dwell Time
IEC/EN 61000-4-3
A
80 MHz - 1000 MHz
3 V/m
1 kHz Sine Wave, 80%, AM Modulation
1% of fundamental
Horizontal and Vertical
3m
1.5 m
at least 3 seconds
5.5.2 MEASUREMENT INSTRUMENTS
6
Serial No.
832080/007
Calibrated until
Sep. 04, 2014
AR
AT1080
320290
N/A
150W1000M1
320946
N/A
FL7004
0320284/03132
98
Apr. 15, 2014
AR
AR
ft
Type No.
SMT06
BOONTON
4232A
10179
Jun. 16, 2014
BOONTON
51011-EMC
SW1006
(Version 1.22)
34150
Jun. 16, 2014
321779
N/A
AR
D
7
Power Sensor
Measurement
Software
Manufacturer
R&S
ra
Item Kind of Equipment
Signal Generator
1
Log-Periodic
2
Antenna
Power Amplifier
3
Laser Power Field
4
Prode
RF Power Meter
5
Remark: “N/A” denotes No Model Name, No Serial No. or No Calibration specified.
5.5.3 TEST PROCEDURE
The EUT and support equipment, which are placed on a table that is 0.8 meter above ground and
the testing was performed in a fully-anechoic chamber.
The testing distance from antenna to the EUT was 3 meters.
The other condition as following manner:
a. The field strength level was 3 V/m.
b. The frequency range is swept from 80 MHz to 1000 MHz, with the signal 80%amplitude
modulated with a 1 kHz sine wave. The rate of sweep did not exceed 1.5x 10-3 decade/s.
Where the frequency range is swept incrementally, the step size was 1% of fundamental.
c. Sweep Frequency 900 MHz, with the Duty Cycle:1/8 and Modulation: Pulse 217 Hz(if
applicable)
d. The dwell time at each frequency shall be not less than the time necessary for the EUT to be
able to respond.
e. The test was performed with the EUT exposed to both vertically and horizontally polarized
fields on each of the four sides.
5.5.4 DEVIATION FROM TEST STANDARD
No deviation
Report No.: NEI-EMC-1-1311149
Page 125 of 170
Neutron Engineering Inc.
RV-0000000
Note:
ra
ft
5.5.5 TEST SETUP
D
TABLE-TOP EQUIPMENT
The EUT installed in a representative system as described in EN 61000-4-3/IEC 61000-4-3 was
placed on a non-conductive table 0.8 meters in height. The system under test was connected to
the power and signal wire according to relevant installation instructions.
FLOOR-STANDING EQUIPMENT
The EUT installed in a representative system as described in EN 61000-4-3/IEC 61000-4-3 was
placed on a non-conductive wood support 0.1 meters in height. The system under test was
connected to the power and signal wire according to relevant installation instructions.
Report No.: NEI-EMC-1-1311149
Page 126 of 170
RV-0000000
Neutron Engineering Inc.
5.5.6 TEST RESULTS
AMOS-820; CPT-1000;
AMOS-820-P
48%
EUT
IPC
Model Name
Temperature
Test Voltage
Test Mode
24°C
Relative Humidity
AC 230V/50Hz / DC 48V
Mode 1 / Mode 2 / Mode 3 / Mode 4 / Mode 5 / Mode 6 / Mode 7
Frequency Range RF Field
(MHz)
Position
R.F.
Field Strength
3 V/m (rms)
80 - 1000
H/V
AM Modulated
1 kHz, 80%
Azimuth
Performance
Criterion
Result
Judgment
A
A
PASS
0
90
180
270
Note:
D
ra
ft
1) P/N denotes the Positive/Negative polarity of the output voltage.
2) N/A - denotes test is not applicable in this test report.
3) Criterion A: No observation of any performance degradation.
4) Criterion B: Some degradation of performance is observed but the equipment continues to operate as
intended.
5) Criterion C: Loss of functionality, but self-recoverable by user, without loss of information or settings.
Report No.: NEI-EMC-1-1311149
Page 127 of 170
RV-0000000
Neutron Engineering Inc.
5.6 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (EFT/BURST)
5.6.1 TEST SPECIFICATION
Basic Standard
Required Performance
Test Voltage
Polarity
Impulse Frequency
Impulse Wave shape
Burst Duration
Burst Period
Test Duration
IEC/EN 61000-4-4
B
Power Line: 1 kV
Signal/Control Line: 0.5 kV
Positive & Negative
5 kHz: except for xDSL equipment
100 kHz: only for single lines of xDSL equipment.
5/50 ns
15 ms
300 ms
Not less than 1 min.
5.6.2 MEASUREMENT INSTRUMENTS
Type No.
Serial No.
Calibrated until
TESEQ
NSG 3060
1558
Apr. 11,2014
TESEQ
TESEQ
ft
Manufacturer
CDN 3061
1452
Apr. 11,2014
VAR 3005-S16
844
Apr. 17,2014
N/A
N/A
0502218
N/A
ra
Item Kind of Equipment
EMC Immunity Test
1
System
EMC Immunity Test
2
System
Single motor driven
3
variable
transformer
Measurement
4
Software
5
Capacitive Clamp
TESEQ
Thermo
WIN 3000
(Version 1.2)
CCL
D
Remark: “N/A” denotes No Model Name, No Serial No. or No Calibration specified.
5.6.3 TEST PROCEDURE
The EUT and support equipment(s) are placed on a table that is 0.8 meter high above a metal
ground plane and should be located 0.1 m+/- 0.01m high above the Ground Reference Plane
(1m*1m min. and 0.65mm thick min).
The other condition as following manner:
a. The length of power cord between the coupling device and the EUT should not exceed 1
meter.
b. Both positive and negative polarity discharges were applied.
c. The duration time of each test sequential was 1 minute
5.6.4 DEVIATION FROM TEST STANDARD
No deviation
Report No.: NEI-EMC-1-1311149
Page 128 of 170
Neutron Engineering Inc.
RV-0000000
D
ra
ft
5.6.5 TEST SETUP
Note:
TABLE-TOP EQUIPMENT
The configuration consisted of a wooden table (0.8m high) standing on the Ground Reference
Plane and should be located 0.1 m+/- 0.01m above the Ground Reference Plane. The GRP
consisted of a sheet of aluminum (at least 0.25mm thick and 2.5m square) connected to the
protective grounding system. A minimum distance of 0.5m was provided between the EUT and the
walls of the laboratory or any other metallic structure.
FLOOR-STANDING EQUIPMENT
The EUT installed in a representative system as described in EN 61000-4-4/IEC 61000-4-4 and its
cables were isolated from the Ground Reference Plane by an insulating support that is 0.1-meter
thick. The GRP consisted of a sheet of aluminum (at least 0.25mm thick and 2.5m square)
connected to the protective grounding system.
Report No.: NEI-EMC-1-1311149
Page 129 of 170
RV-0000000
Neutron Engineering Inc.
5.6.6 TEST RESULTS
EUT
IPC
Model Name
Temperature
Test Voltage
Test Mode
24°C
Relative Humidity
AC 230V/50Hz
Mode 1 / Mode 2 / Mode 3 / Mode 5 / Mode 6
Polarity
+
Line (L)
AC Power Port
-
Neutral (N)
Ground (PE)
EUT Ports Tested
Note:
+
5 kHz
A
-
5 kHz
A
+
5 kHz
A
-
5 kHz
A
Polarity
+
RJ-45
-
B
A
PASS
B
A
PASS
Repetition Test Level Performance
Result Judgment
Frequency 0.5 kV
Criterion
5 kHz
A
B
A
PASS
5 kHz
A
ra
Signal/Data/
Control Port
Repetition Test Level Performance
Result Judgment
1 kV
Frequency
Criterion
5 kHz
A
B
A
PASS
5 kHz
A
ft
EUT Ports Tested
AMOS-820; CPT-1000;
AMOS-820-P
48%
D
1) N/A - denotes test is not applicable in this test report
2) Criterion A: No observation of any performance degradation.
3) Criterion B: Some degradation of performance is observed but the equipment continues to operate as
intended.
4) Criterion C: Loss of functionality, but self-recoverable by user, without loss of information or settings.
Report No.: NEI-EMC-1-1311149
Page 130 of 170
RV-0000000
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
IPC
24°C
DC 48V
Mode 4 / Mode 7
EUT Ports Tested
Signal/Data/
Control Port
Polarity
+
RJ-45
-
Model Name
Relative Humidity
CPT-1000; AMOS-820-P
48%
Repetition Test Level Performance
Result Judgment
Frequency 0.5 kV
Criterion
5 kHz
A
B
A
PASS
5 kHz
A
Note:
D
ra
ft
1) N/A - denotes test is not applicable in this test report
2) Criterion A: No observation of any performance degradation.
3) Criterion B: Some degradation of performance is observed but the equipment continues to operate as
intended.
4) Criterion C: Loss of functionality, but self-recoverable by user, without loss of information or settings.
Report No.: NEI-EMC-1-1311149
Page 131 of 170
RV-0000000
Neutron Engineering Inc.
5.7 SURGE IMMUNITY TEST
5.7.1 TEST SPECIFICATION
Basic Standard
Required Performance
Wave-Shape
Test Voltage
Surge Input/Output
Generator Source
Impedance
Polarity
Phase Angle
Pulse Repetition Rate
Number of Tests
IEC/EN 61000-4-5
B (For Power Line)
Combination Wave for power lines
1.2/50 us Open Circuit Voltage
8 /20 us Short Circuit Current
Power Line: 0.5 kV, 1 kV, 2 kV
L1-L2, L1-PE, L2-PE
2 ohm between networks
12 ohm between network and ground
Positive/Negative
0˚/90˚/180˚/270˚
1 time / min. (maximum)
5 positive and 5 negative at selected points
5.7.2 MEASUREMENT INSTRUMENTS
TESEQ
Serial No.
Calibrated until
NSG 3060
1558
Apr. 11,2014
CDN 3061
1452
Apr. 11,2014
ra
TESEQ
Type No.
ft
Manufacturer
TESEQ
VAR 3005-S16
844
Apr. 17,2014
TESEQ
WIN 3000
(Version 1.2)
N/A
N/A
D
Item Kind of Equipment
EMC Immunity Test
1
System
EMC Immunity Test
2
System
Single motor driven
3
variable
transformer
Measurement
4
Software
Remark: “N/A” denotes No Model Name, No Serial No. or No Calibration specified.
5.7.3 TEST PROCEDURE
a. For EUT power supply:
The surge is to be applied to the EUT power supply terminals via the capacitive coupling
network. Decoupling networks are required in order to avoid possible adverse effects on
equipment not under test that may be powered by the same lines, and to provide sufficient
decoupling impedance to the surge wave. The power cord between the EUT and the
coupling/decoupling networks shall be 2meters in length (or shorter).
b. For test applied to unshielded unsymmetrically operated interconnection lines of EUT:
The surge is applied to the lines via the capacitive coupling. The coupling /decoupling
networks shall not influence the specified functional conditions of the EUT. The
interconnection line between the EUT and the coupling/decoupling networks shall be 2 meters
in length (or shorter).
c. For test applied to unshielded symmetrically operated interconnection /telecommunication
lines of EUT:
The surge is applied to the lines via gas arrestors coupling. Test levels below the ignition point
of the coupling arrestor cannot be specified. The interconnection line between the EUT and
the coupling/decoupling networks shall be 2 meters in length (or shorter).
Report No.: NEI-EMC-1-1311149
Page 132 of 170
RV-0000000
Neutron Engineering Inc.
5.7.4 DEVIATION FROM TEST STANDARD
No deviation
5.7.5 TEST SETUP
AC/DC Power Supply
and Surge Voltage
Coupling to EUT
To AC Mains or
DC Power
Supply
Combination Wave
Generator
Coupling
Network
Decoupling
Network
EUT
D
ra
ft
Non-Metallic Table
Report No.: NEI-EMC-1-1311149
Page 133 of 170
RV-0000000
Neutron Engineering Inc.
5.7.6 TEST RESULTS
EUT
IPC
Model Name
Temperature
Test Voltage
Test Mode
24°C
Relative Humidity
AC 230V/50Hz
Mode 1 / Mode 2 / Mode 3 / Mode 5 / Mode 6
AMOS-820; CPT-1000;
AMOS-820-P
48%
1.2/50(8/20)Tr/Th μs
Wave Form
Performance
Voltage
Result Judgment
EUT Ports Tested Polarity Phase
Criterion
0.5 kV 1 kV -- kV -- kV
A
A
+/0°
°
+/A
A
90
L–N
AC
B
A
PASS
(2 ohm)
+/A
A
180°
+/A
A
270°
Note:
ra
ft
1.2/50(8/20)Tr/Th μs
Wave Form
Performance
Voltage
Result Judgment
EUT Ports Tested Polarity Phase
Criterion
0.5 kV 1 kV 2 kV -- kV
+/A
A
A
0°
A
A
A
+/90°
L – PE
B
A
PASS
(12 ohm)
A
A
A
+/180°
+/A
A
A
270°
AC
°
A
A
A
+/0
+/A
A
A
90°
N – PE
B
A
PASS
(12 ohm)
+/A
A
A
180°
+/A
A
A
270°
D
1) Polarity and Numbers of Impulses:5 Pst / Ngt at each tested mode
2) N/A - denotes test is not applicable in this Test Report
3) Criterion A: No observation of any performance degradation.
4) Criterion B: Some degradation of performance is observed but the equipment continues to operate as
intended.
5) Criterion C: Loss of functionality, but self-recoverable by user, without loss of information or settings.
6) *: Specified by applicant.
Report No.: NEI-EMC-1-1311149
Page 134 of 170
RV-0000000
Neutron Engineering Inc.
5.8 IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
TEST (CS)
5.8.1 TEST SPECIFICATION
Basic Standard
Required Performance
Frequency Range
Field Strength
Modulation
Frequency Step
Dwell Time
IEC/EN 61000-4-6
A
0.15 MHz - 80 MHz
3 Vr.m.s.
1 kHz Sine Wave, 80%, AM Modulation
1% of fundamental
at least 3 seconds
5.8.2 MEASUREMENT INSTRUMENTS
Manufacturer
IFR
Type No.
2023A
Serial No.
202301/368
Calibrated until
Apr. 15, 2014
Power Amplifier
AR
75A250AM1
0320709
N/A
3
CDN(M2)
FCC
FCC-801-M2/M3-16A
100266
Apr. 19, 2014
4
CDN(M3)
FCC
FCC-801-M2/M3-16A
100266
Apr. 19, 2014
5
CDN
FCC
F-090407-1004-1
100520
May. 05, 2014
6
50Ω BNC TYPE
Terminator
N/A
N/A
08
Jul. 04, 2014
7
Measurement
Software
SW1006
(Version 1.13)
321778
N/A
ra
2
ft
Item Kind of Equipment
Signal Generator
1
AR
Remark: “N/A” denotes No Model Name, No Serial No. or No Calibration specified.
D
5.8.3 TEST PROCEDURE
The EUT and support equipment, are placed on a table that is 0.8 meter above a metal ground
plane measured 1m*1m min. and 0.65mm thick min.
The other condition as following manner:
a. The field strength level was 3 Vr.m.s..
b. The frequency range is swept from 150 kHz to 80 MHz, with the signal 80%amplitude
modulated with a 1 kHz sine wave. The rate of sweep did not exceed 1.5x 10-3 decade/s.
Where the frequency range is swept incrementally, the step size was 1% of fundamental.
c. The dwell time at each frequency shall be not less than the time necessary for the
EUT to be able to respond.
5.8.4 DEVIATION FROM TEST STANDARD
No deviation
Report No.: NEI-EMC-1-1311149
Page 135 of 170
RV-0000000
Neutron Engineering Inc.
5.8.5 TEST SETUP
Shielding Room
D ≥ 0.5 m
D ≥ 0.5 m
0.1 m < L <0.3m
S.G
Insulation
Support
Power
Amplifer
EUT
10 cm
GPIB
Control
System
CDN
Ground
Wire
Ground Reference Plane (GRP) Bonded to Earth
ft
Attenuator
6dB/25W
NOTE:
D
ra
FLOOR-STANDING EQUIPMENT
The equipment to be tested is placed on an insulating support of 0.1 meters height above a
ground reference plane. All relevant cables shall be provided with the appropriate coupling and
decoupling devices at a distance between 0.1 meters and 0.3 meters from the projected geometry
of the EUT on the ground reference plane.
Report No.: NEI-EMC-1-1311149
Page 136 of 170
RV-0000000
Neutron Engineering Inc.
5.8.6 TEST RESULTS
EUT
IPC
Temperature
Test Voltage
Test Mode
24°C
Relative Humidity
AC 230V/50Hz
Mode 1 / Mode 2 / Mode 3 / Mode 5 / Mode 6
Test Ports
(Mode)
Model Name
Freq. Range
(MHz)
Field Strength
Input/ Output
AC. Power Port
Input/ Output
DC. Power Port
0.15 - 80
3 Vr.m.s.
AM Modulated
1 kHz, 80%
Performance
Criterion
Result
Judgment
A
A
PASS
A
N/A
N/A
A
A
PASS
ft
Signal Line
(RJ-45)
AMOS-820; CPT-1000;
AMOS-820-P
48%
Note:
D
ra
1) N/A - denotes test is not applicable in this Test Report.
2) Criterion A: No observation of any performance degradation.
3) Criterion B: Some degradation of performance is observed but the equipment continues to operate as
intended.
4) Criterion C: Loss of functionality, but self-recoverable by user, without loss of information or settings.
Report No.: NEI-EMC-1-1311149
Page 137 of 170
RV-0000000
Neutron Engineering Inc.
EUT
Temperature
Test Voltage
Test Mode
IPC
24°C
DC 48V
Mode 4 / Mode 7
Test Ports
(Mode)
Freq. Range
(MHz)
Model Name
Relative Humidity
Field Strength
Input/ Output
AC. Power Port
Input/ Output
DC. Power Port
0.15 - 80
3 Vr.m.s.
AM Modulated
1 kHz, 80%
Signal Line
(RJ-45)
Performance
Criterion
Result
Judgment
A
N/A
N/A
A
N/A
N/A
A
A
PASS
ft
Note:
CPT-1000; AMOS-820-P
48%
D
ra
1) N/A - denotes test is not applicable in this Test Report.
2) Criterion A: No observation of any performance degradation.
3) Criterion B: Some degradation of performance is observed but the equipment continues to operate as
intended.
4) Criterion C: Loss of functionality, but self-recoverable by user, without loss of information or settings.
Report No.: NEI-EMC-1-1311149
Page 138 of 170
RV-0000000
Neutron Engineering Inc.
5.9 POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST (PFMF)
5.9.1 TEST SPECIFICATION
Basic Standard
Required Performance
Frequency Range
Field Strength
Observation Time
Inductance Coil
IEC/EN 61000-4-8
A
50/60 Hz
1 A/m
1 minute
Rectangular type, 1mx1m
5.9.2 MEASUREMENT INSTRUMENTS
Item Kind of Equipment
1
2
Manufacturer
Type No.
Serial No.
Calibrated until
F.W. BELL
4190
0845014
Apr. 28,2014
FCC
F-1000-4-8-G-125A
04029
Apr. 28,2014
FCC
F-1000-4-8/9/10-L-1M
04018
Apr. 28,2014
Magnetic Field Test
Generator
Magnetic Field
Immunity Loop
ft
3
Triaxial ELF Magnetic
Fiedl Meter
Remark: “N/A” denotes No Model Name, No Serial No. or No Calibration specified.
D
ra
5.9.3 TEST PROCEDURE
The EUT and support equipment, are placed on a table that is 0.8 meter above a metal ground
plane measured 1m*1m min. and 0.65mm thick min.
The other condition as following manner:
a. The equipment cabinets shall be connected to the safety earth directly on the GRP via the
earth terminal of the EUT.
b. The cables supplied or recommended by the equipment manufacturer shall be used. 1 meter
of all cables used shall be exposed to the magnetic field.
5.9.4 DEVIATION FROM TEST STANDARD
No deviation
Report No.: NEI-EMC-1-1311149
Page 139 of 170
RV-0000000
Neutron Engineering Inc.
5.9.5 TEST SETUP
EUT
Magnetic
Field
Tester
ft
AC
Source
Note:
D
ra
TABLE-TOP EQUIPMENT
The equipment shall be subjected to the test magnetic field by using the induction coil of standard
dimension (1 m x 1 m). The induction coil shall then be rotated by 90 degrees in order to expose
the EUT to the test field with different orientations.
FLOOR-STANDING EQUIPMENT
The equipment shall be subjected to the test magnetic field by using induction coils of suitable
dimensions. The test shall be repeated by moving and shifting the induction coils, in order to test
the whole volume of the EUT for each orthogonal direction. The test shall be repeated with the coil
shifted to different positions along the side of the EUT, in steps corresponding to 50 percent of the
shortest side of the coil. The induction coil shall then be rotated by 90 degrees in order to expose
the EUT to the test field with different orientations.
Report No.: NEI-EMC-1-1311149
Page 140 of 170
RV-0000000
Neutron Engineering Inc.
5.9.6 TEST RESULTS
AMOS-820; CPT-1000;
AMOS-820-P
48%
EUT
IPC
Model Name
Temperature
Test Voltage
Test Mode
24°C
Relative Humidity
AC 230V/50Hz / DC 48V
Mode 1 / Mode 2 / Mode 3 / Mode 4 / Mode 5 / Mode 6 / Mode 7
Test Mode
Test Level
Antenna
aspect
Duration
(s)
Performance
Criterion
Result
Enclosure
1 A/m
50/60 Hz
X
60
A
A
PASS
Enclosure
1 A/m
50/60 Hz
Y
60
A
A
PASS
Enclosure
1 A/m
50/60 Hz
Z
60
A
A
PASS
Judgment
Note:
D
ra
ft
1) N/A - denotes test is not applicable in this test report
2) Criterion A: No observation of any performance degradation.
3) Criterion B: Some degradation of performance is observed but the equipment continues to operate as
intended.
4) Criterion C: Loss of functionality, but self-recoverable by user, without loss of information or settings.
Report No.: NEI-EMC-1-1311149
Page 141 of 170
RV-0000000
Neutron Engineering Inc.
5.10 VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TEST
5.10.1 TEST SPECIFICATION
Basic Standard
Required Performance
Test Duration Time
Interval between Event
Phase Angle
Test Cycle
IEC/EN 61000-4-11
B (For >95% Voltage Dips)
C (For 30% Voltage Dips)
C (For >95% Voltage Interruptions)
Minimum three test events in sequence
Minimum ten seconds
0°/180°
3 times
5.10.2 MEASUREMENT INSTRUMENTS
Type No.
Serial No.
Calibrated until
TESEQ
NSG 3060
1558
Apr. 11,2014
TESEQ
CDN 3061
1452
Apr. 11,2014
TESEQ
TESEQ
ft
Manufacturer
VAR 3005-S16
844
Apr. 17,2014
WIN 3000
(Version 1.2)
N/A
N/A
ra
Item Kind of Equipment
EMC Immunity Test
1
System
EMC Immunity Test
2
System
Single motor driven
3
variable
transformer
Measurement
4
Software
Remark: “N/A” denotes No Model Name, No Serial No. or No Calibration specified.
D
5.10.3 TEST PROCEDURE
The EUT shall be tested for each selected combination of test levels and duration with a
sequence of three dips/interruptions with intervals of 10 s minimum (between each test event).
Each representative mode of operation shall be tested. Abrupt changes in supply voltage shall
occur at zero crossings of the voltage waveform.
5.10.4 DEVIATION FROM TEST STANDARD
No deviation
Report No.: NEI-EMC-1-1311149
Page 142 of 170
RV-0000000
Neutron Engineering Inc.
5.10.5 TEST SETUP
Voltage Supply
To EUT
To AC Mains
Power Supply
Voltage Dips
Generator
EUT
D
ra
ft
Non-Metallic Table
Report No.: NEI-EMC-1-1311149
Page 143 of 170
RV-0000000
Neutron Engineering Inc.
5.10.6 TEST RESULTS
EUT
IPC
Temperature
Test Voltage
Test Mode
24°C
Relative Humidity
AC 230V/50Hz
Mode 1 / Mode 2 / Mode 3 / Mode 5 / Mode 6
AMOS-820; CPT-1000;
AMOS-820-P
48%
Model Name
Voltage Reduction
Duration
(Periods)
Voltage Dips >95%
0.5
Voltage Dips 30%
AC 100V/50Hz
Performance
Criterion
Result
Judgment
B
A
PASS
25
C
A
PASS
Voltage Interruptions
>95%
250
C
C
PASS
Voltage Reduction
Duration
(Periods)
Voltage Dips >95%
0.5
ft
Result
Judgment
A
PASS
25
C
A
PASS
250
C
C
PASS
Result
Judgment
D
Voltage Interruptions
>95%
B
ra
Voltage Dips 30%
AC 230V/50Hz
Performance
Criterion
AC 240V/50Hz
Performance
Criterion
Voltage Reduction
Duration
(Periods)
Voltage Dips >95%
0.5
B
A
PASS
Voltage Dips 30%
25
C
A
PASS
Voltage Interruptions
>95%
250
C
C
PASS
Note:
1). N/A - denotes test is not applicable in this test report.
2) Criterion A: No observation of any performance degradation.
3) Criterion B: Some degradation of performance is observed but the equipment continues to operate as
intended.
4) Criterion C: Loss of functionality, but self-recoverable by user, without loss of information or settings.
Report No.: NEI-EMC-1-1311149
Page 144 of 170
RV-0000000
Neutron Engineering Inc.
6. EUT TEST PHOTO
Conducted emission test photos
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : FSP060-DBAB1)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 145 of 170
RV-0000000
Neutron Engineering Inc.
Conducted emission test photos
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : ADP-18TB A)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 146 of 170
RV-0000000
Neutron Engineering Inc.
Conducted emission test photos
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 147 of 170
RV-0000000
Neutron Engineering Inc.
Conducted emission test photos
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:FSP060-DBAB1)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 148 of 170
RV-0000000
Neutron Engineering Inc.
Conducted emission test photos
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:ADP-18TB A)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 149 of 170
RV-0000000
Neutron Engineering Inc.
Conducted emission at telecommunication ports test photos
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : FSP060-DBAB1)
(ETHERNET 1G-1G) (ETHERNET 100M-100M) (ETHERNET 10M-10M)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 150 of 170
RV-0000000
Neutron Engineering Inc.
Conducted emission at telecommunication ports test photos
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : ADP-18TB A)
(ETHERNET 1G-1G) (ETHERNET 100M-100M) (ETHERNET 10M-10M)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 151 of 170
RV-0000000
Neutron Engineering Inc.
Conducted emission at telecommunication ports test photos
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B)
(ETHERNET 1G-1G) (ETHERNET 100M-100M) (ETHERNET 10M-10M)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 152 of 170
RV-0000000
Neutron Engineering Inc.
Conducted emission at telecommunication ports test photos
FULL SYSTEM (CPT-1000) (PoE) (ETHERNET 100M-100M) (ETHERNET 10M-10M)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 153 of 170
RV-0000000
Neutron Engineering Inc.
Conducted emission at telecommunication ports test photos
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:FSP060-DBAB1)
(ETHERNET 1G-1G) (ETHERNET 100M-100M) (ETHERNET 10M-10M)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 154 of 170
RV-0000000
Neutron Engineering Inc.
Conducted emission at telecommunication ports test photos
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:ADP-18TB A)
(ETHERNET 1G-1G) (ETHERNET 100M-100M) (ETHERNET 10M-10M)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 155 of 170
RV-0000000
Neutron Engineering Inc.
Conducted emission at telecommunication ports test photos
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (PoE)
(ETHERNET 100M-100M) (ETHERNET 10M-10M)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 156 of 170
RV-0000000
Neutron Engineering Inc.
Radiated emission test photos
Below 1 GHz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : FSP060-DBAB1)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 157 of 170
RV-0000000
Neutron Engineering Inc.
Radiated emission test photos
Below 1 GHz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : ADP-18TB A)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 158 of 170
RV-0000000
Neutron Engineering Inc.
Radiated emission test photos
Below 1 GHz
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 159 of 170
RV-0000000
Neutron Engineering Inc.
Radiated emission test photos
Below 1 GHz
FULL SYSTEM (CPT-1000) (PoE)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 160 of 170
RV-0000000
Neutron Engineering Inc.
Radiated emission test photos
Below 1 GHz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:FSP060-DBAB1)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 161 of 170
RV-0000000
Neutron Engineering Inc.
Radiated emission test photos
Below 1 GHz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:ADP-18TB A)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 162 of 170
RV-0000000
Neutron Engineering Inc.
Radiated emission test photos
Below 1 GHz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (PoE)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 163 of 170
RV-0000000
Neutron Engineering Inc.
Radiated emission test photos
Above 1 GHz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : FSP060-DBAB1)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 164 of 170
RV-0000000
Neutron Engineering Inc.
Radiated emission test photos
Above 1 GHz
FULL SYSTEM HDMI 1920*1080/60Hz(AMOS-820) (Adapter : ADP-18TB A)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 165 of 170
RV-0000000
Neutron Engineering Inc.
Radiated emission test photos
Above 1 GHz
FULL SYSTEM (CPT-1000) (Adapter:ADP-36JH B)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 166 of 170
RV-0000000
Neutron Engineering Inc.
Radiated emission test photos
Above 1 GHz
FULL SYSTEM (CPT-1000) (PoE)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 167 of 170
RV-0000000
Neutron Engineering Inc.
Radiated emission test photos
Above 1 GHz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:FSP060-DBAB1)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 168 of 170
RV-0000000
Neutron Engineering Inc.
Radiated emission test photos
Above 1 GHz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (ADAPTER:ADP-18TB A)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 169 of 170
RV-0000000
Neutron Engineering Inc.
Radiated emission test photos
Above 1 GHz
FULL SYSTEM HDMI 1920*1080/60Hz (AMOS-820-P) (PoE)
D
ra
ft
1311149
Report No.: NEI-EMC-1-1311149
1311149
Page 170 of 170

Similar documents

test report

test report 6. SETUP OF EQUIPMENT UNDER TEST 6.1 SETUP CONFIGURATION OF EUT See test photographs attached in Appendix 1 for the actual connections between EUT and

More information

A Leading Global Manufacturer of Electronic Instruments

A Leading Global Manufacturer of Electronic Instruments www.sunpowerinc.com World leader in free-piston Stirling technology. Engineering services include prototype design, development and fabrication of free-piston Stirling engines. Products include the...

More information

Untitled

Untitled customers with innovative and brand leading products. We are a premier supplier of top quality recognized brands, including Cole Hersee, Warn, Ken-Tool, Permatex and Spray 9. Our expert sourcing an...

More information