test report
Transcription
test report
Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 ETSI EN 301 489-17 V1.2.1: 2002 TEST REPORT For Bluetooth USB Hub Model: MS-6871 Trade Name: MSI Issued to MICRO-STAR INT'L CO., LTD. NO. 69, Li-De St, Jung-He City, Taipei Hsien, Taiwan, R.O.C. Issued by Compliance Certification Services Inc. No. 81-1, Lane 210, Bade Rd. 2, Luchu Hsiang, Taoyuan Hsien, (338) Taiwan, R.O.C. TEL: 886-3-324-0332 FAX: 886-3-324-5235 Note: This report shall not be reproduced except in full, without the written approval of Compliance Certification Services Inc. This document may be altered or revised by Compliance Certification Services Inc. personnel only, and shall be noted in the revision section of the document. Page 1 Total Page: 45 Rev. 00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 TABLE OF CONTENTS 1. TEST RESULT CERTIFICATION............................................................................................. 3 2. EUT DESCRIPTION..................................................................................................................... 4 3. TEST METHODOLOGY.............................................................................................................. 5 3.1 3.2 3.3 3.4 UNIT OF MEASUREMENT ............................................................................................... 5 ANTENNA ..................................................................................................................... 5 MEASUREMENT EQUIPMENT USED .................................................................. 6 DECISION OF FINAL TEST MODE .................................................................................... 9 4. INSTRUMENT AND CALIBRATION...................................................................................... 10 4.1 MEASURING INSTRUMENT CALIBRATION.................................................... 10 5. FACILITIES AND ACCREDITATIONS.................................................................................. 11 5.1 5.2 5.3 5.4 FACILITIES ................................................................................................................. 11 EQUIPMENT ................................................................................................................ 11 LABORATORY ACCREDITATIONS AND LISTINGS .......................................................... 11 TABLE OF ACCREDITATIONS AND LISTINGS ............................................................... 12 6. SETUP OF EQUIPMENT UNDER TEST................................................................................. 13 6.1 6.2 6.3 SETUP CONFIGURATION OF EUT .................................................................................. 13 SUPPORT EQUIPMENT......................................................................................... 13 TEST SETUP ................................................................................................................ 14 7. ETSI EN 301 489-1/-17 REQUIREMENTS............................................................................... 15 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 7.9 7.10 RADIATED EMISSION .................................................................................................. 15 AC MAINS LINE CONDUCTED EMISSION ....................................................................... 17 AC MAINS HARMONIC CURRENT EMISSION ................................................................. 20 AC MAINS VOLTAGE FLUCTUATION AND FLICKER ...................................................... 22 ELECTROSTATIC DISCHARGE ...................................................................................... 24 RF ELECTROMAGNETIC FIELD ..................................................................................... 30 AC MAINS FAST TRANSIENTS – COMMON MODE .......................................................... 32 AC MAINS SURGE ........................................................................................................ 34 AC MAINS RF – COMMON MODE .................................................................................. 36 VOLTAGE DIPS AND INTERRUPTION ............................................................................ 38 Page 2 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 1. TEST RESULT CERTIFICATION Applicant: MICRO-STAR INT'L CO., LTD. NO. 69, Li-De St, Jung-He City, Taipei Hsien, Taiwan, R.O.C. Equipment Under Test: Bluetooth USB Hub Trade Name: MSI Model: MS-6871 Date of Test: November 10 ~ December 1, 2004 APPLICABLE STANDARDS STANDARD TEST RESULT ETSI EN 301 489-17 V1.2.1: 2002 No non-compliance noted Applicable Standard Class/Limit/Criterion Test Result EN 55022: 1998 Class B No non-compliance noted EN 61000-3-2: 2000 Class D No non-compliance noted EN 61000-3-3: 1995 + A1: 2001 Limit No non-compliance noted EN 61000-4-2: 1995 + A2: 2001 Criterion B No non-compliance noted EN 61000-4-3: 2002 + A1: 2002 Criterion A No non-compliance noted EN 61000-4-4: 1995 + A2: 2001 Criterion B No non-compliance noted EN 61000-4-5: 1995 + A1: 2001 Criterion B No non-compliance noted EN 61000-4-6: 1996 + A1: 2001 Criterion A No non-compliance noted EN 61000-4-11: 1994 + A1: 2001 Criterion B/C/C No non-compliance noted ETSI EN 301 489-1 V1.4.1: 2002 Deviation from Applicable Standard None The above equipment was tested by Compliance Certification Services Inc. for compliance with the requirements set forth in ETSI EN 301 489-17 V1.2.1: 2002. The results of testing in this report apply only to the product/system, which was tested. Other similar equipment will not necessarily produce the same results due to production tolerance and measurement uncertainties. Approved by: Reviewed by: Harris. W. Lai Executive Vice President Compliance Certification Services Inc. Devin Chang Section Manager Compliance Certification Services Inc. Page 3 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 2. EUT DESCRIPTION Product Bluetooth USB Hub Trade Name MSI Model Number MS-6871 Model Discrepancy N/A Module Trade Name MSI Module Model Number MS6970 Power Supply DC 5V from upstream USB port Frequency Range 2402 ~ 2480 MHz Transmit Power (mean EIRP) 4.09dBm Modulation Technique GFSK (16-QAM, 64-QAM) Number of Channels 79 Channels Antenna Specification Printed Antenna / Gain: -4.1dBi Temperature Range 0 ~ +50°C Note: for more details, please refer to the User’s manual of the EUT. Page 4 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 3. TEST METHODOLOGY All tests were performed in accordance with the procedure documented in ETSI EN 301 489-1 V1.4.1 (2002-04) as referenced in ETSI EN 301 489-17 V1.2.1 (2002-04). 3.1 UNIT OF MEASUREMENT Measurements of radiated interference are reported in terms of dB(uV/m) at a specified distance. The indicated readings on the Spectrum analyzers were converted to dB (uV/m) by use of appropriate conversion factors. Measurements of conducted interference are reported in terms of dB(uV). The field strength is calculated by adding the Antenna Factor and Cable Factors and subtracting the Amplifier Gain from the measured reading. The following is a sample calculation: FS = RA + AF + CF – AG Where FS = Field Strength RA = Receiver Amplitude AF = Antenna Factor CF = Cable Attenuation Factor AG = Amplifier Gain Assume a receiver reading of 52.5 dBuV is obtained. The Antenna Factor of 7.4dB/m and a Cable Factor of 1.1dB are added. The Amplifier Gain of 29 dB is subtracted, giving field strength of 32 dBuV/m. The 32-dBuV/m values was mathematically converted to its corresponding level in uV/m. FS = 52.5 + 7.4 + 1.1 – 29 = 32 dBuV/m Note: Level in uV/m = Common Antilogarithm [(32 dBuV/m)/20] = 39.8 uV/m 3.2 ANTENNA The calibrated antennas used to sample the radiated field strength are mounted on a non-conductive, motorized antenna mast 10 meters from the leading edge of the turntable. Page 5 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 3.3 MEASUREMENT EQUIPMENT USED Equipment Used for Emission Measurement Remark: Each piece of equipment is scheduled for calibration once a year. Open Area Test Site # 3 Name of Equipment Manufacturer Model Serial Number Calibration Due Spectrum Analyzer ADVANTEST R3132 91700456 N.C.R EMI Test Receiver R&S ESVS10 846285/016 04/10/2005 Bilog Antenna CHASE CBL 6112B 2462 01/10/2005 Turn Table Chance most N/A N/A N.C.R Antenna Tower Chance most N/A N/A N.C.R Controller Chance most N/A N/A N.C.R RF Switch ANRITSU MP59B M51067 N.C.R Site NSA C&C Lab. N/A N/A 08/08/2005 Test S/W HTBasic (M026C) Conducted Emission Test Site # 3 Name of Equipment Manufacturer Model Serial Number Calibration Due EMI TEST RECEIVER 9kHz-30MHz TWO-LINE V-NETWORK 9kHz-30MHz ROHDE & SCHWARZ ESHS30 828144/003 09/24/2005 SCHAFFNER NNB41 03/10013 06/11/2005 EMCO 3825/2 9106-1809 02/05/2005 LISN 10kHz-100MHz Test S/W LabABVIEW (V 6.1) Power Harmonic & Voltage Fluctuation/Flicker Measurement (EN 61000-3-2&-3-3) Name of Equipment Manufacturer Model Harmonic & Flicker Tester EMC-PARTNER HARMONICS-1000 Test S/W Serial Number Calibration Due 094 10/26/2005 HARCS (Ver. 4.0) Page 6 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 Equipment Used for Immunity Measurement ESD Test Site (IEC/EN 61000-4-2) Name of Equipment Manufacturer Model ESD Simulator NoiseKen ESS-2001 Serial Number Calibration Due ESS0210582 09/13/2005 Radiated Electromagnetic Field Immunity Test Site (IEC/EN 61000-4-3) Name of Equipment Manufacturer Model Signal Generator Agilent 8648C 4108A05772 09/12/2005 150W1000M3 306730 N.C.R 30S1G3M1 306722 N.C.R 150 Watts 80-1000MHz Amplifier Research Amplifier 30 Watts 0.8-3.0GHz Amplifier Research Amplifier Serial Number Calibration Due Power Meter Boonton 4232A-01-02 98501 07/09/2005 Power Sensor Boonton 51011-EMC 32920 07/09/2005 Power Sensor Boonton 51011-EMC 32863 07/09/2005 Log-Periodic Antenna Amplifier Research AT1080 306709 N.C.R AT4002A 306750 N.C.R FG-506 50608090006 05/18/2005 SC1000M3 306666 N.C.R Microwave Horn Antenna Amplifier Research 6 MHz Sweep/Function AMREL Generator RF Test System Amplifier Research Controller Field Probe Amplifier Research FP6001 305657 03/17/2005 0.8-4.2GHz Amplifier Research DC7144A N/A N.C.R 80-1000MHz Amplifier Research DC6180A N/A N.C.R Antenna Tower Amplifier Research TP2000 N/A N.C.R Probe Stand Amplifier Research PS2000 N/A N.C.R Test S/W SW1005 (Release 1.4) Fast Transients/Burst Test Site (IEC/EN 61000-4-4) Name of Equipment Manufacturer Fast Transients/Burst Generator HAEFELY TRENCH HAEFELY TRENCH Clamp Test S/W Model Serial Number Calibration Due PEFT- JUNIOR 583 333-117 08/19/2005 093 506.1 080 421.13 N.C.R E400 Burstware (V4.19 (c)) Remark: The clamp is used only for EUT with signal cable connected and greater than 3m in length. Page 7 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 Surge Immunity Test Site (IEC/EN EN 61000-4-5) Name of Equipment Surge Tester CDN CDN Manufacturer HAEFELY TRENCH HAEFELY TRENCH HAEFELY TRENCH Test S/W Model Serial Number Calibration Due PSUGER 4010 583 334-71 09/02/2005 IP6.2 148342 N.C.R. DEC1A 148050 N.C.R. E500 Surgeware (V4.19cc) CS Test Site (IEC/EN 61000-4-6) Name of Equipment Manufacturer Model Signal Generator Agilent 8648C 4108A05773 09/12/2005 75A250AM1 306334 N.C.R 75 Watts 10kHz-250MHz Amplifier Research Amplifier Serial Number Calibration Due Power Meter Boonton 4232A-01-02 98601 07/09/2005 Power Sensor Boonton 51011-EMC 32862 07/09/2005 Power Sensor Boonton 51011-EMC 32864 07/09/2005 03018 09/13/2005 03026 09/06/2005 03027 09/13/2005 03016 09/06/2005 03017 09/06/2005 421 09/13/2005 03053&03054 09/13/2005 408 09/13/2005 04024 09/13/2005 Power Line Coupling Decoupling Network Power Line Coupling Decoupling Network Power Line Coupling Decoupling Network Signal Line Coupling Decoupling Network Signal Line Coupling Decoupling Network EM Injection Clamp Passive Impedance Adapters Calibration Fixture Signal Line Coupling Decoupling Network Fischer Custom FCC-801-M1-32A Communications, Inc. Fischer Custom FCC-801-M2-16A Communications, Inc. Fischer Custom FCC-801-M3-16A Communications, Inc. Fischer Custom FCC-801-T2 Communications, Inc. Fischer Custom FCC-801-T4 Communications, Inc. Fischer Custom F-203I-23mm Communications, Inc. Fischer Custom FCC-801-150-50-CDN Communications, Inc. Fischer Custom F-203I-CF-23mm Communications, Inc. Fischer Custom FCC-801-T8-RJ45 Communications, Inc. Attenuator Amplifier Research HFP-575-3/6-NM NF201875106 N.C.R Coupler Amplifier Research DC2600A 306621 N.C.R Test S/W SW1005 (Release 1.4) Page 8 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 Voltage Dips/Short Interruption and Voltage Variation Immunity Test Site (IEC/EN 61000-4-11) Name of Equipment Manufacturer Model Dips/Interruption and Variations Simulator HAEFELY TRENCH PLINE 1610 Test S/W Serial Number Calibration Due 080 344-05 04/07/2005 WinPATS (V. 3.26) 3.4 DECISION OF FINAL TEST MODE 1. The following test mode was scanned during the preliminary test: Mode 1 Transceiving --- (Operated with the Highest channel under IEEE 802.11b mode) Mode 2 Transceiving --- (Operated with the Highest channel under IEEE 802.11g mode) 2. After the preliminary scan, the following test mode was found to produce the highest emission level. Mode 2 Then, the EUT configuration and cable configuration of the above highest emission mode was chosen for all final test items. Page 9 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 4. INSTRUMENT AND CALIBRATION 4.1 MEASURING INSTRUMENT CALIBRATION The measuring equipment, which was utilized in performing the tests documented herein, has been calibrated in accordance with the manufacturer’s recommendations for utilizing calibration equipment, which is traceable to recognized national standards. Page 10 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 5. FACILITIES AND ACCREDITATIONS 5.1 FACILITIES All measurement facilities used to collect the measurement data are located at No. 81-1, Lane 210, Bade Rd. 2, Luchu Hsiang, Taoyuan Hsien, Taiwan, R.O.C. No. 199, Chunghsen Road, Hsintien City, Taipei Hsien, Taiwan, R.O.C. The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 and CISPR Publication 22. 5.2 EQUIPMENT Radiated emissions are measured with one or more of the following types of linearly polarized antennas: tuned dipole, biconical, log periodic, bi-log, and/or ridged waveguide, horn. Spectrum analyzers with preselectors and quasi-peak detectors are used to perform radiated measurements. Conducted emissions are measured with Line Impedance Stabilization Networks and EMI Test Receivers. Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used for making measurements. All receiving equipment conforms to CISPR Publication 16-1, “Radio Interference Measuring Apparatus and Measurement Methods.” 5.3 LABORATORY ACCREDITATIONS AND LISTINGS The test facilities used to perform radiated and conducted emissions tests are accredited by National Voluntary Laboratory Accreditation Program for the specific scope of accreditation under Lab Code: 200600-0 to perform Electromagnetic Interference tests according to FCC PART 15 AND CISPR 22 requirements. No part of this report may be used to claim or imply product endorsement by NVLAP or any agency of the US Government. In addition, the test facilities are listed with Federal Communications Commission (registration no: 93105 and 90471). Page 11 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 5.4 TABLE OF ACCREDITATIONS AND LISTINGS Country USA USA Agency Scope of Accreditation EN 55011, EN 55014-1, AS/NZS 1044, CNS 13783-1, EN 55022, CNS 13438, NVLAP* EN 61000-3-2, EN 61000-3-3, ANSI C63.4, FCC OST/MP-5, AS/NZS CISPR 22, IEC 61000-4-2/3/4/5/6/8/11 FCC 3/10 meter Open Area Test Sites to perform FCC Part 15/18 measurements Logo 200600-0 93105, 90471 VCCI 4 3/10 meter Open Area Test Sites to perform conducted/radiated measurements NEMKO EN 50081-1/2, EN 50082-1/2, IEC 61000-6-1/2, EN 50091-2, EN 50130-4, EN 55011, EN 55013, EN 55014-1/2, EN 55015, EN 55022, EN 55024, EN 61000-3-2/3, EN 61326-1, IEC 61000-4-2/3/4/5/6/8/11, EN 60601-1-2, ELA 124a EN 300 328-2, EN 300 422-2, EN 301 419-1, ELA 124b EN 301 489-01/03/07/08/09/17, EN 301 419-2/3, ELA 124c EN 300 454-2, EN 301 357-2 Taiwan CNLA EN 300 328-1/2, EN 300 220-1/2/3, EN 300 440-1/2, EN 61000-3-2, EN 61000-3-3, 47 CFR FCC Part 15 Subpart C/D/E, EN 55013, CNS 13439, EN 55014-1, CNS 13783-1, EN 55022, CNS 13438, CISPR 22, AS/NZS 3548, EN 61000-4-2/3/4/5/6/8/11, ENV 50204, IEEE Std 1528, FCC OET Bulletin, 65+Supplement C, EN50360, EN50361, EN50371, RSS102 Taiwan BSMI CNS 13438, CNS 13783-1, CNS 13439, CNS 14115 SL2-IS-E-0014 SL2-IN-E-0014 SL2-A1-E-0014 SL2-R1-E-0014 SL2-R2-E-0014 SL2-L1-E-0014 Canada Industry Canada RSS212, Issue 1 IC 3991-3 IC 3991-4 Japan Norway R-393/1066/725/879 C-402/747/912 * No part of this report may be used to claim or imply product endorsement by NVLAP or any agency of the US Government. Page 12 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 6. SETUP OF EQUIPMENT UNDER TEST 6.1 SETUP CONFIGURATION OF EUT See test photographs attached in Appendix 1 for the actual connections between EUT and support equipment. 6.2 SUPPORT EQUIPMENT No. Device Type Brand Model Series No. FCC ID Data Cable Power Cord 1. LCD Monitor BenQ FP557 99L4672AC132500150TP1AC1 FCC DoC Shielded, 1.8m with two cores 2. USB Keyboard Compaq KU-9978 B463AOAGALT097 FCC DoC Shielded, 1.8m N/A 3. USB Mouse HP MO19UCA 020440964 FCC DoC Shielded, 1.8m N/A 4. Printer EPSON STYLUS C60 DR3K039633 FCC DoC Shielded, 1.8m Unshielded, 1.8m 5. USB 2.0 HDD TeraSyS F12-U A0100214-31d0014 FCC DoC Shielded, 1.8m Unshielded, 1.8m 6. Notebook PC IBM 2656 AK-VF0HT FCC DoC Shielded, 1.8m with two cores Unshielded, 1.8m 7. Notebook PC Toshiba Satellite 1110 Y2382109 FCC DoC Shielded, 1.8m with two cores Unshielded, 1.8m Unshielded, 1.8m Notes: 1. All the equipment/cables were placed in the worst-case configuration to maximize the emission during the test. 2. Grounding was established in accordance with the manufacturer’s requirements and conditions for the intended use. Page 13 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 6.3 TEST SETUP The equipment under test was configured and operated in a manner to communicate with Bluetooth USB Hub continuously. EUT tends to maximize its emission characteristics in a typical application for conducted and radiated emission measurement. The RF module plus ancillary (stand alone unit) was evaluated as per table 2 of clause 7.1 of ETSI Final draft ETSI EN 301 489-1 V1.4.1: 20002. The transmitter was active during the conducted and radiated emission measurements. Software Used During the Test Windows XP 1. Boot up Windows XP. Program Sequence 2. Connect and link the auxiliary bluetooth dongle. RF Management Software S/W provided applicant. Operating System Remark: During the test, no modification is made to the EUT to comply with Class B limit levels. Page 14 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 7. ETSI EN 301 489-1/-17 REQUIREMENTS 7.1 RADIATED EMISSION LIMIT Please refer to ETSI EN 301 489-1 Clause 8.2.3, Table 4 and EN 55022 Clause 6, Table 6, Class B Test Configuration Turntable 1m ~ 4m EUT Coaxial Cable Power Cable 0.8 m 10 m Filter Filter Ground Plane To Power EMI Receiver Page 15 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 8.2.3 and EN 55022 Clause 6 for the measurement methods. TEST RESULTS No non-compliance noted Test Data Location: Site # 3 Tested by: Tom Jen Test Mode: Mod 2 Test Distance: 10m Detector Function: Quasi-peak Test Results: Passed Safe Margins (dB) Note 30.00 -4.53 Peak 23.90 30.00 -6.10 Peak 16.50 27.55 37.00 -9.45 Peak 12.24 16.50 28.74 37.00 -8.26 Peak H 12.60 16.64 29.24 37.00 -7.76 Peak H 7.89 16.48 24.37 37.00 -12.63 Peak Freq. (MHz) Ant. V/H Reading (dBuV) Factor (dB) Actual FS Limits(QP) (dBuV/m) (dBuV/m) 66.00 V 15.80 9.67 25.47 226.65 V 7.61 16.29 240.15 V 11.05 240.15 H 249.15 280.65 N/A N/A Note: 1. Measuring frequencies from 30 MHz to the 1GHz. 2. Radiated emissions measured in frequency range from 30 MHz to 1000MHz were made with an instrument using Peak detector mode. 3. Field strength limits for frequency above 1000MHz are based on average limits. However, Peak mode field strength shall not exceed the average limits specified plus 20dB. 4. Measurements above show only up to 6 maximum emissions noted. 5. The IF bandwidth of SPA 30MHz to 1GHz was 100kHz. Page 16 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 7.2 AC MAINS LINE CONDUCTED EMISSION LIMIT Please refer to ETSI EN 301 489-1 Clause 8.4.3, Table 8 and EN 55022 Clause 5, Table 2, Class B Test Configuration V ert. reference plane E M I receiver EUT L IS N R eference ground plane TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 8.4.3 and EN 55022 Clause 5 for the measurement methods. Page 17 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 TEST RESULTS No non-compliance noted Test Data Operation Mode: TX + RX mode o Temperature: 25 C Humidity: 55% RH Test Date: November 12, 2004 Tested by: Tom Jen Freq. QP AV (MHz) Reading Reading Corr. factor QP Result AV Result QP Margin AV Note Margin 0.194 43.710 36.060 0.076 43.786 36.136 63.864 53.864 -20.077 -17.727 L1 0.302 39.470 36.240 0.090 39.560 36.330 60.188 50.188 -20.628 -13.858 L1 0.541 49.940 38.860 0.110 50.050 38.970 56.000 46.000 -5.950 -7.030 L1 1.259 42.720 29.260 0.118 42.838 29.378 56.000 46.000 -13.162 -16.622 L1 3.328 41.290 29.780 0.207 41.497 29.987 56.000 46.000 -14.503 -16.013 L1 9.605 31.070 26.670 0.360 31.430 27.030 60.000 50.000 -28.570 -22.970 L1 0.192 40.350 38.020 0.067 40.417 38.087 63.950 53.950 -23.533 -15.863 L2 0.305 34.030 32.000 0.090 34.120 32.090 60.106 50.106 -25.986 -18.016 L2 0.563 41.720 34.900 0.129 41.849 35.029 56.000 46.000 -14.151 -10.971 L2 1.269 37.150 36.150 0.125 37.275 36.275 56.000 46.000 -18.725 -9.725 L2 3.302 35.840 33.390 0.179 36.019 33.569 56.000 46.000 -19.981 -12.431 L2 6.983 28.480 26.230 0.309 28.789 26.539 60.000 50.000 -31.211 -23.461 L2 QP Limit AV Limit Remark: 1. The measuring frequencies range between 0.15 MHz and 30 MHz. 2. The emissions measured in the frequency range between 0.15 MHz and 30MHz were made with an instrument using Quasi-peak detector and Average detector. 3. “---” denotes the emission level was or more than 2dB below the Average limit, and no re-check was made. 4. The IF bandwidth of SPA between 0.15MHz and 30MHz was 10kHz. The IF bandwidth of Test Receiver between 0.15MHz and 30MHz was 9kHz. 5. L1 = Line One (Live Line) / L2 = Line Two (Neutral Line) Page 18 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 Test Plot Conducted emissions (Line 1) Conducted emissions (Line 2) Page 19 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 7.3 AC MAINS HARMONIC CURRENT EMISSION LIMIT Please refer to EN 61000-3-2 Test Configuration Harmonics & Flicker Analyzer + Power Source Power Cord EUT Support Units 0.8m Ambient Condition of the Test Site Temperature 25°C EUT AC Voltage Rating 230 Vac, 50 Hz Humidity 55%RH EUT DC Voltage Rating N/A Tested by Tom Jen Ground Bond Resistance 0.2 Ω TEST PROCEDURE Please refer to EN 61000-3-2 for the measurement methods. TEST RESULTS No non-compliance noted. Note: According to clause 7 of EN 61000-3-2, equipment with a rated power of 75W or less, no limits apply. The test result is only for reference. Page 20 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 Harmonic Emission - IEC 61000-3-2, EN 61000-3-2, (EN60555-2) Comply: IEC 61000-3-2 Ed.2.1: 2001 (incl. Amd.14) - IEC 61000-4-7 Ed.1.0: 1991 MICRO-STAR HARCS Setup File : unnamed HARCS Report File : unnamed Remarks Bluetooth USB Hub ms-6781 Tom Temp : 25'C Humidity : 55% RH Full Bar : Actual Values Empty Bar : Maximum Values Blue : Current , Green : Voltage , Red : Failed Page 21 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 7.4 AC MAINS VOLTAGE FLUCTUATION AND FLICKER LIMIT Please refer to EN 61000-3-3 Test Configuration (Same as the configuration of the AC MAINS HARMONIC CURRENT EMISSIONS TEST) Ambient Condition of the Test Site Temperature 25°C EUT AC Voltage Rating 230 Vac, 50 Hz Humidity 55%RH EUT DC Voltage Rating N/A Tested by Tom Jen Ground Bond Resistance 0.2 Ω TEST PROCEDURE Please refer to EN 61000-3-3 for the measurement methods. TEST RESULTS No non-compliance noted. Page 22 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 Flicker Emission - IEC 61000-3-3, EN 61000-3-3, (EN60555-3) Comply: IEC 61000-3-3 Ed.1.1: 2002 (incl. Amd.1) - IEC 61000-4-15 Ed.1.0: 1997 (incl. Amd.1) MICRO-STAR HARCS Setup File: unnamed HARCS Report File: unnamed Bluetooth USB Hub ms-6781 Tom Remarks Full Bar : Actual Values Empty Bar : Maximum Values Circles : Average Values Blue : Current , Green : Voltage , Red : Failed Page 23 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 7.5 ELECTROSTATIC DISCHARGE LIMIT Please refer to EN 61000-4-2 Test Configuration VCP EUT & its direct Support Units Indirect Support units HCP >1m Wooden Table 0.8m Ground Reference Plane Ambient Condition of the Test Site Temperature 28°C EUT AC Voltage Rating 230 Vac, 50 Hz Humidity 40%RH EUT DC Voltage Rating N/A Pressure 1019 mbar Ground Bond Resistance 0.2 Ω Tested by Tom Jen Page 24 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 9.3.2 and EN 61000-4-2 for the measurement methods. TEST RESULTS PASS (System will be recovered itself after the temporary service suspension which caused by the interference applied.) Description of the Electrostatic Discharges (ESD) Operating Mode Amount of Discharges Voltage Coupling Result (Pass/Fail) Mini 20 / Point ±4kV Contact Discharge Pass Mini 20 / Point ±8kV Air Discharge Pass Mini 20 / Point ±4kV Indirect Discharge HCP Pass Mini 20 / Point ±4kV Indirect Discharge VCP Pass Note: For tested points to EUT, refer to the enclosed pages. Be aware that the Blue mark is for contact discharge, and the red mark is for air discharge. PERFORMANCE CRITERIA Criteria requested A/ B/ C Criteria meet A/ B/ C Standby Mode Amount of Discharges Voltage Coupling Result (Pass/Fail) Mini 20 / Point ±4kV Contact Discharge Pass Mini 20 / Point ±8kV Air Discharge Pass Mini 20 / Point ±4kV Indirect Discharge HCP Pass Mini 20 / Point ±4kV Indirect Discharge VCP Pass Note: For tested points to EUT, refer to the enclosed pages. Be aware that the Blue mark is for contact discharge, and the red mark is for air discharge. PERFORMANCE CRITERIA Criteria requested A/ B/ C Criteria meet A/ B/ C Page 25 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 The Tested Points of EUT Page 26 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 Page 27 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 Page 28 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 Page 29 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 7.6 RF ELECTROMAGNETIC FIELD LIMIT Please refer to EN 61000-4-3 Test Configuration 3 meter 7x3x3 EUT & Support Units 1.5 meter 0.8m Power Amp Signal Generator PC Controller to control S.G. & PA as well as forward power EUT Monitoring by using a camera Control Room Page 30 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 Ambient Condition of the Test Site Temperature 23°C EUT AC Voltage Rating 230 Vac, 50 Hz Humidity 40%RH EUT DC Voltage Rating N/A Pressure 1019 mbar Ground Bond Resistance 0.2 Ω Tested by Tom Jen TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 9.2.2, ETSI EN 301 489-17 Clause 7.2 and EN 61000-4-3 for the measurement methods. TEST RESULTS PASS (EUT continued to operate normally during test) Description of Preliminary Test (Operating & Standby Modes) Field Modulation Polarity Position (°) 1 Freq. Range (MHz) 80-2000 6V/m Yes H/V Front 2 80-2000 6V/m Yes H/V Right 3 80-2000 6V/m Yes H/V Back 4 80-2000 6V/m Yes H/V Left Selection for the final test Result of Final Tests (Operating Mode) Freq. Range (MHz) Field Modulation Polarity Position (°) Result (Pass/Fail) 80-2000 3V/m Yes H/V Front Pass PERFORMANCE CRITERIA Criteria requested A/ B/ C Criteria meet A/ B/ C Results of Final Tests (Standby Mode) Freq. Range (MHz) Field Modulation Polarity Position (°) Result (Pass/Fail) 80-2000 3V/m Yes H/V Front Pass PERFORMANCE CRITERIA Criteria requested A/ B/ C Criteria meet A/ B/ C Page 31 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 7.7 AC MAINS FAST TRANSIENTS – COMMON MODE LIMIT Please refer to EN 61000-4-4 Test Configuration EUT AC Line EFT/Burst/ Surge Generator 0.8m Support Units Non-Conductive Table Controller Computer Comm. Line ≧ 3 m To Load EUT 10cm AC Line Burst Generator Injection Clamp Non-Conductive Table 0.8m Ambient Condition of the Test Site Temperature 23°C EUT AC Voltage Rating 230 Vac, 50 Hz Humidity 40%RH EUT DC Voltage Rating N/A Pressure 1019 mbar Ground Bond Resistance 0.2 Ω Tested by Tom Jen Page 32 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 9.4.2 and EN 61000-4-4 for the measurement methods. TEST RESULTS PASS (EUT continued to operate normally during test) TEST CONDITIONS Results of Final Tests (Operating Mode) Impulse Frequency: 5 kHz Tr/Th: 5/50ns Burst Duration: 15ms Burst Period: 3Hz Injection Line Voltage (kV) Injected Method Line ±1 Direct Neutral ±1 Direct Direct PE ±1 Line + Neutral ±1 Direct Direct L + PE ±1 Direct N + PE ±1 Direct L + N + PE ±1 RJ45 port (LAN cable) ±0.5 Clamp RJ11 port (Line cable) ±0.5 Clamp PERFORMANCE CRITERIA Criteria requested A/ B/ Criteria meet A/ B/ Results of Final Tests (Standby Mode) Impulse Frequency: 5 kHz Tr/Th: 5/50ns Burst Duration: 15ms Burst Period: 3Hz Injection Line Voltage (kV) Line ±1 Neutral ±1 PE ±1 Line + Neutral ±1 L + PE ±1 N + PE ±1 L + N + PE ±1 RJ45 port (LAN cable) ±0.5 RJ11 port (Line cable) ±0.5 C C Injected Method Direct Direct Direct Direct Direct Direct Direct Clamp Clamp PERFORMANCE CRITERIA Criteria requested A/ B/ Criteria meet A/ B/ Page 33 Result (Pass / Fail) Pass Pass Pass Pass Pass Pass Pass Pass Pass Result (Pass / Fail) Pass Pass Pass Pass Pass Pass Pass Pass Pass C C Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 7.8 AC MAINS SURGE LIMIT Please refer to EN 61000-4-5 Test Configuration To AC Source Surge Immunity Test EUT & Support Units 0.8m Controller Computer Ambient Condition of the Test Site Temperature Humidity Pressure Tested by 23°C 40%RH 1019 mbar Tom Jen EUT AC Voltage Rating EUT DC Voltage Rating Ground Bond Resistance 230 Vac, 50 Hz N/A 0.2 Ω TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 9.8.2 and EN 61000-4-5 for the measurement methods. Page 34 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 TEST RESULTS PASS (EUT continued to operate normally during test) Test conditions Results of Final Tests (Operating Mode) Voltage Waveform: 1.2/50 us Current Waveform: 8/20 us Polarity: Positive/Negative Phase angle: 0o, 90o, 180 o, 270o Coupling Line Voltage (kV) Polarity Coupling Method Result (Pass/Fail) Line + Neutral 1 Pos./ Neg. Capacitive Pass L + PE 1 Pos./ Neg. Capacitive Pass N + PE 1 Pos./ Neg. Capacitive Pass T, R-Ground 0.5 Pos./ Neg. Capacitive Pass L1, 2, 3, 4-G (LAN) 0.5 Pos./ Neg. Capacitive Pass PERFORMANCE CRITERIA Criteria requested A/ B/ C Criteria meet A/ B/ C Results of Final Tests (Standby Mode) Voltage Waveform: 1.2/50 us Current Waveform: 8/20 us Polarity: Positive/Negative Phase angle: 0o, 90o, 180 o, 270o Coupling Line Voltage (kV) Polarity Coupling Method Result (Pass/Fail) Line + Neutral 1 Pos./ Neg. Capacitive Pass L + PE 1 Pos./ Neg. Capacitive Pass N + PE 1 Pos./ Neg. Capacitive Pass T, R-Ground 0.5 Pos./ Neg. Capacitive Pass L1, 2, 3, 4-G (LAN) 0.5 Pos./ Neg. Capacitive Pass PERFORMANCE CRITERIA Criteria requested A/ B/ C Criteria meet A/ B/ C Page 35 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 7.9 AC MAINS RF – COMMON MODE LIMIT Please refer to EN 61000-4-6 Test Configuration 0.1m< L <0.3m 10 cm isolation supporter EUT and Support units Power Amplifier CDN PC Controller Ground Reference Plane Ambient Condition of the Test Site Temperature 23°C EUT AC Voltage Rating 230 Vac, 50 Hz Humidity 40%RH EUT DC Voltage Rating N/A Pressure 1019 mbar Ground Bond Resistance 0.2 Ω Tested by Tom Jen Page 36 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 TEST PROCEDURE Please refer to ETSIETSI EN 301 489-1 Clause 9.5.2, ETSI EN 301 489-17 Clause 7.2.2 and EN 61000-4-6 for the measurement methods. TEST RESULTS PASS (EUT continued to operate normally during test) TEST CONDITIONS Results of Final Tests (Operating Mode) Frequency Range: 0.15MHz~80MHz Frequency Step: 1% of fundamental Dwell time: 3 Sec. 80% A.M., 1 kHz Sine wave (Field Strength: 3 V/m) Coupling type: CDN: FCC-801-M3-16A / RF Current Probe Range (MHz) Field Modulation Result (Pass/Fail) 0.15-80 3V/m Yes Pass PERFORMANCE CRITERIA Criteria requested A/ B/ C Criteria meet A/ B/ C Results of Final Tests (Standby Mode) Frequency Range: 0.15MHz~80MHz Frequency Step: 1% of fundamental Dwell time: 3 Sec. 80% A.M., 1 kHz Sine wave (Field Strength: 3 V/m) Coupling type: CDN: FCC-801-M3-16A / RF Current Probe Range (MHz) Field Modulation Result (Pass/Fail) 0.15-80 3V/m Yes Pass PERFORMANCE CRITERIA Criteria requested A/ B/ Criteria meet A/ B/ C C Page 37 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 7.10 VOLTAGE DIPS AND INTERRUPTION LIMIT Please refer to EN 61000-4-11 Test Configuration To AC Source Dips/Interruption and Variations Simulator EUT & Support Units 0.8m Controller Computer Ambient Condition of the Test Site Temperature 23°C EUT AC Voltage Rating 230 Vac, 50 Hz Humidity 40%RH EUT DC Voltage Rating N/A Pressure 1019 mbar Ground Bond Resistance 0.2 Ω Tested by Tom Jen TEST PROCEDURE Please refer to ETSI EN 301 489-1 Clause 9.7.2 and EN 61000-4-11 for the measurement methods. Page 38 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 TEST RESULTS PASS (for criteria A: EUT continued to operate normally during test) (for criteria B: EUT shut down, but can be auto recovered as the events disappear.) (for criteria C: EUT shut down, but can be recovered by manual, as the events disappear.) TEST CONDITIONS Interruption at phase angles of 0, 45, 90, 135, 180, 225, 270 and 315 degree in a 10 sec-interval. Test Level (% UT) Reduction (%) Duration (ms) Criterion 70 30% 10 B 40 60% 100 C <5 >95% 5000 C Voltage Dips Voltage Interruption Note: The duration with a sequence of three dips/interruptions with a minimum interval of 10 s between each test event. Results of Final Tests (Operating Mode) Voltage Dips Test Level (% UT) Reduction (%) Duration (ms) Observation Criterion 70 30 10 Normal A 40 60 100 Normal B Voltage Interruption Test Level (% UT) Reduction (%) Duration (ms) Observation Criterion <5 95 5000 Normal C Results of Final Tests (Standby Mode) Voltage Dips Test Level (% UT) Reduction (%) Duration (ms) Observation Criterion 70 30 10 Normal A 40 60 100 Normal B Voltage Interruption Test Level (% UT) Reduction (%) Duration (ms) Observation Criterion <5 95 5000 Normal C Page 39 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 APPENDIX 1 PHOTOGRAPHS OF TEST SETUP RADIATED EMISSION TEST (EN 55022) Page 40 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 LINE CONDUCTED EMISSION TEST (EN 55022) Page 41 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 POWER HARMONICS &VOLTAGE FLUCTUATION / FLICKER (EN 61000-3-2/EN 61000-3-3) Page 42 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 ELECTROSTATIC DISCHARGE TEST (EN 61000-4-2) RADIATED ELECTROMAGNETIC FIELD (EN 61000-4-3) Page 43 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 FAST TRANSIENTS/BURST TEST (EN 61000-4-4) SURGE IMMUNITY TEST (EN 61000-4-5) Page 44 Rev.00 Compliance Certification Services Inc. Report No: 41104402-RE Date of Issue: December 7, 2004 CONDUCTED DISTURBANCE, INDUCED BY RADIO-FREQUENCY FIELDS TEST (EN 61000-4-6) VOLTAGE DIPS/ INTERRUPTION TEST (EN 61000-4-11) Page 45 Rev.00
Similar documents
Neutron Engineering Inc.
CB08: (VCCI RN: G-91; FCC RN: 614388; FCC DN: TW1054; IC Assigned Code: 4428C-1) 1F., No. 61, Ln. 77, Sing-ai Rd., Neihu Dist., Taipei City 114, Taiwan (R.O.C.)
More informationAPPLICATION FOR CERTIFICATION On Behalf of Futaba
10.1. Photos of Conducted Disturbance Measurement.................................................................................. 50 10.2. Photos of Radiated Measurement at Semi-Anechoic Chamber ...
More information