test report

Transcription

test report
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
ETSI EN 301 489-17 V1.2.1: 2002
TEST REPORT
For
Bluetooth USB Hub
Model: MS-6871
Trade Name: MSI
Issued to
MICRO-STAR INT'L CO., LTD.
NO. 69, Li-De St, Jung-He City,
Taipei Hsien, Taiwan, R.O.C.
Issued by
Compliance Certification Services Inc.
No. 81-1, Lane 210, Bade Rd. 2, Luchu Hsiang,
Taoyuan Hsien, (338) Taiwan, R.O.C.
TEL: 886-3-324-0332
FAX: 886-3-324-5235
Note: This report shall not be reproduced except in full, without the written approval of Compliance
Certification Services Inc. This document may be altered or revised by Compliance Certification
Services Inc. personnel only, and shall be noted in the revision section of the document.
Page 1
Total Page: 45
Rev. 00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
TABLE OF CONTENTS
1. TEST RESULT CERTIFICATION............................................................................................. 3
2. EUT DESCRIPTION..................................................................................................................... 4
3. TEST METHODOLOGY.............................................................................................................. 5
3.1
3.2
3.3
3.4
UNIT OF MEASUREMENT ............................................................................................... 5
ANTENNA ..................................................................................................................... 5
MEASUREMENT EQUIPMENT USED .................................................................. 6
DECISION OF FINAL TEST MODE .................................................................................... 9
4. INSTRUMENT AND CALIBRATION...................................................................................... 10
4.1
MEASURING INSTRUMENT CALIBRATION.................................................... 10
5. FACILITIES AND ACCREDITATIONS.................................................................................. 11
5.1
5.2
5.3
5.4
FACILITIES ................................................................................................................. 11
EQUIPMENT ................................................................................................................ 11
LABORATORY ACCREDITATIONS AND LISTINGS .......................................................... 11
TABLE OF ACCREDITATIONS AND LISTINGS ............................................................... 12
6. SETUP OF EQUIPMENT UNDER TEST................................................................................. 13
6.1
6.2
6.3
SETUP CONFIGURATION OF EUT .................................................................................. 13
SUPPORT EQUIPMENT......................................................................................... 13
TEST SETUP ................................................................................................................ 14
7. ETSI EN 301 489-1/-17 REQUIREMENTS............................................................................... 15
7.1
7.2
7.3
7.4
7.5
7.6
7.7
7.8
7.9
7.10
RADIATED EMISSION .................................................................................................. 15
AC MAINS LINE CONDUCTED EMISSION ....................................................................... 17
AC MAINS HARMONIC CURRENT EMISSION ................................................................. 20
AC MAINS VOLTAGE FLUCTUATION AND FLICKER ...................................................... 22
ELECTROSTATIC DISCHARGE ...................................................................................... 24
RF ELECTROMAGNETIC FIELD ..................................................................................... 30
AC MAINS FAST TRANSIENTS – COMMON MODE .......................................................... 32
AC MAINS SURGE ........................................................................................................ 34
AC MAINS RF – COMMON MODE .................................................................................. 36
VOLTAGE DIPS AND INTERRUPTION ............................................................................ 38
Page 2
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
1. TEST RESULT CERTIFICATION
Applicant:
MICRO-STAR INT'L CO., LTD.
NO. 69, Li-De St, Jung-He City,
Taipei Hsien, Taiwan, R.O.C.
Equipment Under Test:
Bluetooth USB Hub
Trade Name:
MSI
Model:
MS-6871
Date of Test:
November 10 ~ December 1, 2004
APPLICABLE STANDARDS
STANDARD
TEST RESULT
ETSI EN 301 489-17 V1.2.1: 2002
No non-compliance noted
Applicable Standard
Class/Limit/Criterion
Test Result
EN 55022: 1998
Class B
No non-compliance noted
EN 61000-3-2: 2000
Class D
No non-compliance noted
EN 61000-3-3: 1995 + A1: 2001
Limit
No non-compliance noted
EN 61000-4-2: 1995 + A2: 2001
Criterion B
No non-compliance noted
EN 61000-4-3: 2002 + A1: 2002
Criterion A
No non-compliance noted
EN 61000-4-4: 1995 + A2: 2001
Criterion B
No non-compliance noted
EN 61000-4-5: 1995 + A1: 2001
Criterion B
No non-compliance noted
EN 61000-4-6: 1996 + A1: 2001
Criterion A
No non-compliance noted
EN 61000-4-11: 1994 + A1: 2001
Criterion B/C/C
No non-compliance noted
ETSI EN 301 489-1 V1.4.1: 2002
Deviation from Applicable Standard
None
The above equipment was tested by Compliance Certification Services Inc. for compliance with
the requirements set forth in ETSI EN 301 489-17 V1.2.1: 2002. The results of testing in this report
apply only to the product/system, which was tested. Other similar equipment will not necessarily
produce the same results due to production tolerance and measurement uncertainties.
Approved by:
Reviewed by:
Harris. W. Lai
Executive Vice President
Compliance Certification Services Inc.
Devin Chang
Section Manager
Compliance Certification Services Inc.
Page 3
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
2. EUT DESCRIPTION
Product
Bluetooth USB Hub
Trade Name
MSI
Model Number
MS-6871
Model Discrepancy
N/A
Module Trade Name
MSI
Module Model Number
MS6970
Power Supply
DC 5V from upstream USB port
Frequency Range
2402 ~ 2480 MHz
Transmit Power
(mean EIRP)
4.09dBm
Modulation Technique
GFSK (16-QAM, 64-QAM)
Number of Channels
79 Channels
Antenna Specification
Printed Antenna / Gain: -4.1dBi
Temperature Range
0 ~ +50°C
Note: for more details, please refer to the User’s manual of the EUT.
Page 4
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
3. TEST METHODOLOGY
All tests were performed in accordance with the procedure documented in ETSI EN 301 489-1
V1.4.1 (2002-04) as referenced in ETSI EN 301 489-17 V1.2.1 (2002-04).
3.1 UNIT OF MEASUREMENT
Measurements of radiated interference are reported in terms of dB(uV/m) at a specified distance.
The indicated readings on the Spectrum analyzers were converted to dB (uV/m) by use of
appropriate conversion factors. Measurements of conducted interference are reported in terms of
dB(uV).
The field strength is calculated by adding the Antenna Factor and Cable Factors and subtracting
the Amplifier Gain from the measured reading. The following is a sample calculation:
FS = RA + AF + CF – AG
Where FS = Field Strength
RA = Receiver Amplitude
AF = Antenna Factor
CF = Cable Attenuation Factor
AG = Amplifier Gain
Assume a receiver reading of 52.5 dBuV is obtained. The Antenna Factor of 7.4dB/m and a
Cable Factor of 1.1dB are added. The Amplifier Gain of 29 dB is subtracted, giving field
strength of 32 dBuV/m. The 32-dBuV/m values was mathematically converted to its
corresponding level in uV/m.
FS = 52.5 + 7.4 + 1.1 – 29 = 32 dBuV/m
Note: Level in uV/m = Common Antilogarithm [(32 dBuV/m)/20] = 39.8 uV/m
3.2 ANTENNA
The calibrated antennas used to sample the radiated field strength are mounted on a
non-conductive, motorized antenna mast 10 meters from the leading edge of the turntable.
Page 5
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
3.3 MEASUREMENT EQUIPMENT USED
Equipment Used for Emission Measurement
Remark: Each piece of equipment is scheduled for calibration once a year.
Open Area Test Site # 3
Name of Equipment
Manufacturer
Model
Serial Number
Calibration Due
Spectrum Analyzer
ADVANTEST
R3132
91700456
N.C.R
EMI Test Receiver
R&S
ESVS10
846285/016
04/10/2005
Bilog Antenna
CHASE
CBL 6112B
2462
01/10/2005
Turn Table
Chance most
N/A
N/A
N.C.R
Antenna Tower
Chance most
N/A
N/A
N.C.R
Controller
Chance most
N/A
N/A
N.C.R
RF Switch
ANRITSU
MP59B
M51067
N.C.R
Site NSA
C&C Lab.
N/A
N/A
08/08/2005
Test S/W
HTBasic (M026C)
Conducted Emission Test Site # 3
Name of Equipment
Manufacturer
Model
Serial Number
Calibration Due
EMI TEST RECEIVER
9kHz-30MHz
TWO-LINE
V-NETWORK
9kHz-30MHz
ROHDE &
SCHWARZ
ESHS30
828144/003
09/24/2005
SCHAFFNER
NNB41
03/10013
06/11/2005
EMCO
3825/2
9106-1809
02/05/2005
LISN 10kHz-100MHz
Test S/W
LabABVIEW (V 6.1)
Power Harmonic & Voltage Fluctuation/Flicker Measurement (EN 61000-3-2&-3-3)
Name of Equipment
Manufacturer
Model
Harmonic & Flicker
Tester
EMC-PARTNER
HARMONICS-1000
Test S/W
Serial Number Calibration Due
094
10/26/2005
HARCS (Ver. 4.0)
Page 6
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
Equipment Used for Immunity Measurement
ESD Test Site (IEC/EN 61000-4-2)
Name of Equipment
Manufacturer
Model
ESD Simulator
NoiseKen
ESS-2001
Serial Number Calibration Due
ESS0210582
09/13/2005
Radiated Electromagnetic Field Immunity Test Site (IEC/EN 61000-4-3)
Name of Equipment
Manufacturer
Model
Signal Generator
Agilent
8648C
4108A05772
09/12/2005
150W1000M3
306730
N.C.R
30S1G3M1
306722
N.C.R
150 Watts 80-1000MHz
Amplifier Research
Amplifier
30 Watts 0.8-3.0GHz
Amplifier Research
Amplifier
Serial Number Calibration Due
Power Meter
Boonton
4232A-01-02
98501
07/09/2005
Power Sensor
Boonton
51011-EMC
32920
07/09/2005
Power Sensor
Boonton
51011-EMC
32863
07/09/2005
Log-Periodic Antenna
Amplifier Research
AT1080
306709
N.C.R
AT4002A
306750
N.C.R
FG-506
50608090006
05/18/2005
SC1000M3
306666
N.C.R
Microwave Horn Antenna Amplifier Research
6 MHz Sweep/Function
AMREL
Generator
RF Test System
Amplifier Research
Controller
Field Probe
Amplifier Research
FP6001
305657
03/17/2005
0.8-4.2GHz
Amplifier Research
DC7144A
N/A
N.C.R
80-1000MHz
Amplifier Research
DC6180A
N/A
N.C.R
Antenna Tower
Amplifier Research
TP2000
N/A
N.C.R
Probe Stand
Amplifier Research
PS2000
N/A
N.C.R
Test S/W
SW1005 (Release 1.4)
Fast Transients/Burst Test Site (IEC/EN 61000-4-4)
Name of Equipment
Manufacturer
Fast Transients/Burst
Generator
HAEFELY
TRENCH
HAEFELY
TRENCH
Clamp
Test S/W
Model
Serial Number Calibration Due
PEFT- JUNIOR
583 333-117
08/19/2005
093 506.1
080 421.13
N.C.R
E400 Burstware (V4.19 (c))
Remark: The clamp is used only for EUT with signal cable connected and greater than 3m in length.
Page 7
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
Surge Immunity Test Site (IEC/EN EN 61000-4-5)
Name of Equipment
Surge Tester
CDN
CDN
Manufacturer
HAEFELY
TRENCH
HAEFELY
TRENCH
HAEFELY
TRENCH
Test S/W
Model
Serial Number Calibration Due
PSUGER 4010
583 334-71
09/02/2005
IP6.2
148342
N.C.R.
DEC1A
148050
N.C.R.
E500 Surgeware (V4.19cc)
CS Test Site (IEC/EN 61000-4-6)
Name of Equipment
Manufacturer
Model
Signal Generator
Agilent
8648C
4108A05773
09/12/2005
75A250AM1
306334
N.C.R
75 Watts 10kHz-250MHz
Amplifier Research
Amplifier
Serial Number Calibration Due
Power Meter
Boonton
4232A-01-02
98601
07/09/2005
Power Sensor
Boonton
51011-EMC
32862
07/09/2005
Power Sensor
Boonton
51011-EMC
32864
07/09/2005
03018
09/13/2005
03026
09/06/2005
03027
09/13/2005
03016
09/06/2005
03017
09/06/2005
421
09/13/2005
03053&03054
09/13/2005
408
09/13/2005
04024
09/13/2005
Power Line Coupling
Decoupling Network
Power Line Coupling
Decoupling Network
Power Line Coupling
Decoupling Network
Signal Line Coupling
Decoupling Network
Signal Line Coupling
Decoupling Network
EM Injection Clamp
Passive Impedance
Adapters
Calibration Fixture
Signal Line Coupling
Decoupling Network
Fischer Custom
FCC-801-M1-32A
Communications, Inc.
Fischer Custom
FCC-801-M2-16A
Communications, Inc.
Fischer Custom
FCC-801-M3-16A
Communications, Inc.
Fischer Custom
FCC-801-T2
Communications, Inc.
Fischer Custom
FCC-801-T4
Communications, Inc.
Fischer Custom
F-203I-23mm
Communications, Inc.
Fischer Custom
FCC-801-150-50-CDN
Communications, Inc.
Fischer Custom
F-203I-CF-23mm
Communications, Inc.
Fischer Custom
FCC-801-T8-RJ45
Communications, Inc.
Attenuator
Amplifier Research
HFP-575-3/6-NM
NF201875106
N.C.R
Coupler
Amplifier Research
DC2600A
306621
N.C.R
Test S/W
SW1005 (Release 1.4)
Page 8
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
Voltage Dips/Short Interruption and Voltage Variation Immunity Test Site (IEC/EN 61000-4-11)
Name of Equipment
Manufacturer
Model
Dips/Interruption and
Variations Simulator
HAEFELY
TRENCH
PLINE 1610
Test S/W
Serial Number Calibration Due
080 344-05
04/07/2005
WinPATS (V. 3.26)
3.4 DECISION OF FINAL TEST MODE
1.
The following test mode was scanned during the preliminary test:
Mode 1
Transceiving --- (Operated with the Highest channel under IEEE 802.11b mode)
Mode 2
Transceiving --- (Operated with the Highest channel under IEEE 802.11g mode)
2.
After the preliminary scan, the following test mode was found to produce the highest
emission level.
Mode 2
Then, the EUT configuration and cable configuration of the above highest emission mode
was chosen for all final test items.
Page 9
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
4. INSTRUMENT AND CALIBRATION
4.1 MEASURING INSTRUMENT CALIBRATION
The measuring equipment, which was utilized in performing the tests documented herein, has
been calibrated in accordance with the manufacturer’s recommendations for utilizing calibration
equipment, which is traceable to recognized national standards.
Page 10
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
5. FACILITIES AND ACCREDITATIONS
5.1 FACILITIES
All measurement facilities used to collect the measurement data are located at
No. 81-1, Lane 210, Bade Rd. 2, Luchu Hsiang, Taoyuan Hsien, Taiwan, R.O.C.
No. 199, Chunghsen Road, Hsintien City, Taipei Hsien, Taiwan, R.O.C.
The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 and
CISPR Publication 22.
5.2 EQUIPMENT
Radiated emissions are measured with one or more of the following types of linearly polarized
antennas: tuned dipole, biconical, log periodic, bi-log, and/or ridged waveguide, horn. Spectrum
analyzers with preselectors and quasi-peak detectors are used to perform radiated measurements.
Conducted emissions are measured with Line Impedance Stabilization Networks and EMI Test
Receivers.
Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used for
making measurements.
All receiving equipment conforms to CISPR Publication 16-1, “Radio Interference Measuring
Apparatus and Measurement Methods.”
5.3 LABORATORY ACCREDITATIONS AND LISTINGS
The test facilities used to perform radiated and conducted emissions tests are accredited by
National Voluntary Laboratory Accreditation Program for the specific scope of accreditation
under Lab Code: 200600-0 to perform Electromagnetic Interference tests according to FCC
PART 15 AND CISPR 22 requirements. No part of this report may be used to claim or imply
product endorsement by NVLAP or any agency of the US Government. In addition, the test
facilities are listed with Federal Communications Commission (registration no: 93105 and
90471).
Page 11
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
5.4 TABLE OF ACCREDITATIONS AND LISTINGS
Country
USA
USA
Agency
Scope of Accreditation
EN 55011, EN 55014-1, AS/NZS 1044,
CNS 13783-1, EN 55022, CNS 13438,
NVLAP* EN 61000-3-2, EN 61000-3-3, ANSI C63.4,
FCC OST/MP-5, AS/NZS CISPR 22,
IEC 61000-4-2/3/4/5/6/8/11
FCC
3/10 meter Open Area Test Sites to perform FCC
Part 15/18 measurements
Logo
200600-0
93105, 90471
VCCI
4 3/10 meter Open Area Test Sites to perform
conducted/radiated measurements
NEMKO
EN 50081-1/2, EN 50082-1/2, IEC 61000-6-1/2,
EN 50091-2, EN 50130-4, EN 55011, EN 55013,
EN 55014-1/2, EN 55015, EN 55022,
EN 55024, EN 61000-3-2/3, EN 61326-1,
IEC 61000-4-2/3/4/5/6/8/11, EN 60601-1-2,
ELA 124a
EN 300 328-2, EN 300 422-2, EN 301 419-1,
ELA 124b
EN 301 489-01/03/07/08/09/17, EN 301 419-2/3, ELA 124c
EN 300 454-2, EN 301 357-2
Taiwan
CNLA
EN 300 328-1/2, EN 300 220-1/2/3,
EN 300 440-1/2, EN 61000-3-2, EN 61000-3-3,
47 CFR FCC Part 15 Subpart C/D/E,
EN 55013, CNS 13439, EN 55014-1, CNS
13783-1, EN 55022, CNS 13438, CISPR 22,
AS/NZS 3548, EN 61000-4-2/3/4/5/6/8/11,
ENV 50204, IEEE Std 1528, FCC OET Bulletin,
65+Supplement C, EN50360, EN50361,
EN50371, RSS102
Taiwan
BSMI
CNS 13438, CNS 13783-1, CNS 13439,
CNS 14115
SL2-IS-E-0014
SL2-IN-E-0014
SL2-A1-E-0014
SL2-R1-E-0014
SL2-R2-E-0014
SL2-L1-E-0014
Canada
Industry
Canada
RSS212, Issue 1
IC 3991-3
IC 3991-4
Japan
Norway
R-393/1066/725/879
C-402/747/912
* No part of this report may be used to claim or imply product endorsement by NVLAP or any
agency of the US Government.
Page 12
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
6. SETUP OF EQUIPMENT UNDER TEST
6.1 SETUP CONFIGURATION OF EUT
See test photographs attached in Appendix 1 for the actual connections between EUT and
support equipment.
6.2 SUPPORT EQUIPMENT
No. Device Type
Brand
Model
Series No.
FCC ID
Data Cable
Power Cord
1.
LCD Monitor
BenQ
FP557
99L4672AC132500150TP1AC1
FCC
DoC
Shielded, 1.8m
with two cores
2.
USB Keyboard
Compaq
KU-9978
B463AOAGALT097
FCC
DoC
Shielded, 1.8m
N/A
3.
USB Mouse
HP
MO19UCA
020440964
FCC
DoC
Shielded, 1.8m
N/A
4.
Printer
EPSON
STYLUS C60
DR3K039633
FCC
DoC
Shielded, 1.8m
Unshielded, 1.8m
5.
USB 2.0 HDD
TeraSyS
F12-U
A0100214-31d0014
FCC
DoC
Shielded, 1.8m
Unshielded, 1.8m
6.
Notebook PC
IBM
2656
AK-VF0HT
FCC
DoC
Shielded, 1.8m
with two cores
Unshielded, 1.8m
7.
Notebook PC
Toshiba
Satellite 1110
Y2382109
FCC
DoC
Shielded, 1.8m
with two cores
Unshielded, 1.8m
Unshielded, 1.8m
Notes:
1. All the equipment/cables were placed in the worst-case configuration to maximize the
emission during the test.
2. Grounding was established in accordance with the manufacturer’s requirements and
conditions for the intended use.
Page 13
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
6.3 TEST SETUP
The equipment under test was configured and operated in a manner to communicate with
Bluetooth USB Hub continuously. EUT tends to maximize its emission characteristics in a
typical application for conducted and radiated emission measurement. The RF module plus
ancillary (stand alone unit) was evaluated as per table 2 of clause 7.1 of ETSI Final draft ETSI
EN 301 489-1 V1.4.1: 20002. The transmitter was active during the conducted and radiated emission
measurements.
Software Used During the Test
Windows XP
1. Boot up Windows XP.
Program Sequence
2. Connect and link the auxiliary bluetooth dongle.
RF Management Software S/W provided applicant.
Operating System
Remark: During the test, no modification is made to the EUT to comply with Class B limit levels.
Page 14
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
7. ETSI EN 301 489-1/-17 REQUIREMENTS
7.1 RADIATED EMISSION
LIMIT
Please refer to ETSI EN 301 489-1 Clause 8.2.3, Table 4 and EN 55022 Clause 6, Table 6, Class B
Test Configuration
Turntable
1m ~ 4m
EUT
Coaxial
Cable
Power
Cable
0.8 m
10 m
Filter
Filter
Ground Plane
To
Power
EMI
Receiver
Page 15
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
TEST PROCEDURE
Please refer to ETSI EN 301 489-1 Clause 8.2.3 and EN 55022 Clause 6 for the measurement
methods.
TEST RESULTS
No non-compliance noted
Test Data
Location: Site # 3
Tested by: Tom Jen
Test Mode: Mod 2
Test Distance: 10m
Detector Function: Quasi-peak
Test Results: Passed
Safe
Margins
(dB)
Note
30.00
-4.53
Peak
23.90
30.00
-6.10
Peak
16.50
27.55
37.00
-9.45
Peak
12.24
16.50
28.74
37.00
-8.26
Peak
H
12.60
16.64
29.24
37.00
-7.76
Peak
H
7.89
16.48
24.37
37.00
-12.63
Peak
Freq.
(MHz)
Ant.
V/H
Reading
(dBuV)
Factor
(dB)
Actual FS Limits(QP)
(dBuV/m) (dBuV/m)
66.00
V
15.80
9.67
25.47
226.65
V
7.61
16.29
240.15
V
11.05
240.15
H
249.15
280.65
N/A
N/A
Note:
1. Measuring frequencies from 30 MHz to the 1GHz.
2. Radiated emissions measured in frequency range from 30 MHz to 1000MHz were made
with an instrument using Peak detector mode.
3. Field strength limits for frequency above 1000MHz are based on average limits.
However, Peak mode field strength shall not exceed the average limits specified plus
20dB.
4. Measurements above show only up to 6 maximum emissions noted.
5. The IF bandwidth of SPA 30MHz to 1GHz was 100kHz.
Page 16
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
7.2 AC MAINS LINE CONDUCTED EMISSION
LIMIT
Please refer to ETSI EN 301 489-1 Clause 8.4.3, Table 8 and EN 55022 Clause 5, Table 2, Class B
Test Configuration
V ert. reference
plane
E M I receiver
EUT
L IS N
R eference ground plane
TEST PROCEDURE
Please refer to ETSI EN 301 489-1 Clause 8.4.3 and EN 55022 Clause 5 for the measurement
methods.
Page 17
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
TEST RESULTS
No non-compliance noted
Test Data
Operation Mode:
TX + RX mode
o
Temperature:
25 C
Humidity:
55% RH
Test Date:
November 12, 2004
Tested by:
Tom Jen
Freq.
QP
AV
(MHz) Reading Reading
Corr.
factor
QP
Result
AV
Result
QP
Margin
AV
Note
Margin
0.194
43.710
36.060
0.076
43.786
36.136
63.864
53.864
-20.077
-17.727
L1
0.302
39.470
36.240
0.090
39.560
36.330
60.188
50.188
-20.628
-13.858
L1
0.541
49.940
38.860
0.110
50.050
38.970
56.000
46.000
-5.950
-7.030
L1
1.259
42.720
29.260
0.118
42.838
29.378
56.000
46.000
-13.162
-16.622
L1
3.328
41.290
29.780
0.207
41.497
29.987
56.000
46.000
-14.503
-16.013
L1
9.605
31.070
26.670
0.360
31.430
27.030
60.000
50.000
-28.570
-22.970
L1
0.192
40.350
38.020
0.067
40.417
38.087
63.950
53.950
-23.533
-15.863
L2
0.305
34.030
32.000
0.090
34.120
32.090
60.106
50.106
-25.986
-18.016
L2
0.563
41.720
34.900
0.129
41.849
35.029
56.000
46.000
-14.151
-10.971
L2
1.269
37.150
36.150
0.125
37.275
36.275
56.000
46.000
-18.725
-9.725
L2
3.302
35.840
33.390
0.179
36.019
33.569
56.000
46.000
-19.981
-12.431
L2
6.983
28.480
26.230
0.309
28.789
26.539
60.000
50.000
-31.211
-23.461
L2
QP Limit AV Limit
Remark:
1. The measuring frequencies range between 0.15 MHz and 30 MHz.
2. The emissions measured in the frequency range between 0.15 MHz and 30MHz were made
with an instrument using Quasi-peak detector and Average detector.
3. “---” denotes the emission level was or more than 2dB below the Average limit, and no
re-check was made.
4. The IF bandwidth of SPA between 0.15MHz and 30MHz was 10kHz. The IF bandwidth of
Test Receiver between 0.15MHz and 30MHz was 9kHz.
5. L1 = Line One (Live Line) / L2 = Line Two (Neutral Line)
Page 18
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
Test Plot
Conducted emissions (Line 1)
Conducted emissions (Line 2)
Page 19
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
7.3 AC MAINS HARMONIC CURRENT EMISSION
LIMIT
Please refer to EN 61000-3-2
Test Configuration
Harmonics & Flicker
Analyzer
+
Power Source
Power Cord
EUT
Support Units
0.8m
Ambient Condition of the Test Site
Temperature
25°C
EUT AC Voltage Rating
230 Vac, 50 Hz
Humidity
55%RH
EUT DC Voltage Rating
N/A
Tested by
Tom Jen
Ground Bond Resistance
0.2 Ω
TEST PROCEDURE
Please refer to EN 61000-3-2 for the measurement methods.
TEST RESULTS
No non-compliance noted.
Note: According to clause 7 of EN 61000-3-2, equipment with a rated power of 75W or less, no
limits apply. The test result is only for reference.
Page 20
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
Harmonic Emission - IEC 61000-3-2, EN 61000-3-2, (EN60555-2)
Comply: IEC 61000-3-2 Ed.2.1: 2001 (incl. Amd.14) - IEC 61000-4-7 Ed.1.0: 1991
MICRO-STAR
HARCS Setup File : unnamed
HARCS Report File : unnamed
Remarks
Bluetooth USB Hub
ms-6781
Tom
Temp : 25'C Humidity : 55% RH
Full Bar : Actual Values
Empty Bar : Maximum Values
Blue : Current , Green : Voltage , Red : Failed
Page 21
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
7.4 AC MAINS VOLTAGE FLUCTUATION AND FLICKER
LIMIT
Please refer to EN 61000-3-3
Test Configuration
(Same as the configuration of the AC MAINS HARMONIC CURRENT EMISSIONS TEST)
Ambient Condition of the Test Site
Temperature
25°C
EUT AC Voltage Rating
230 Vac, 50 Hz
Humidity
55%RH
EUT DC Voltage Rating
N/A
Tested by
Tom Jen
Ground Bond Resistance
0.2 Ω
TEST PROCEDURE
Please refer to EN 61000-3-3 for the measurement methods.
TEST RESULTS
No non-compliance noted.
Page 22
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
Flicker Emission - IEC 61000-3-3, EN 61000-3-3, (EN60555-3)
Comply: IEC 61000-3-3 Ed.1.1: 2002 (incl. Amd.1) - IEC 61000-4-15 Ed.1.0: 1997
(incl. Amd.1)
MICRO-STAR
HARCS Setup File: unnamed
HARCS Report File: unnamed
Bluetooth USB Hub
ms-6781
Tom
Remarks
Full Bar
: Actual Values
Empty Bar : Maximum Values
Circles
: Average Values
Blue : Current , Green : Voltage , Red : Failed
Page 23
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
7.5 ELECTROSTATIC DISCHARGE
LIMIT
Please refer to EN 61000-4-2
Test Configuration
VCP
EUT & its
direct
Support Units
Indirect
Support units
HCP
>1m
Wooden Table
0.8m
Ground Reference Plane
Ambient Condition of the Test Site
Temperature
28°C
EUT AC Voltage Rating
230 Vac, 50 Hz
Humidity
40%RH
EUT DC Voltage Rating
N/A
Pressure
1019 mbar
Ground Bond Resistance
0.2 Ω
Tested by
Tom Jen
Page 24
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
TEST PROCEDURE
Please refer to ETSI EN 301 489-1 Clause 9.3.2 and EN 61000-4-2 for the measurement
methods.
TEST RESULTS
PASS (System will be recovered itself after the temporary service suspension which caused by
the interference applied.)
Description of the Electrostatic Discharges (ESD)
Operating Mode
Amount of Discharges
Voltage
Coupling
Result (Pass/Fail)
Mini 20 / Point
±4kV
Contact Discharge
Pass
Mini 20 / Point
±8kV
Air Discharge
Pass
Mini 20 / Point
±4kV
Indirect Discharge HCP
Pass
Mini 20 / Point
±4kV
Indirect Discharge VCP
Pass
Note: For tested points to EUT, refer to the enclosed pages. Be aware that the Blue mark is for
contact discharge, and the red mark is for air discharge.
PERFORMANCE CRITERIA
Criteria requested
A/
B/
C
Criteria meet
A/
B/
C
Standby Mode
Amount of Discharges
Voltage
Coupling
Result (Pass/Fail)
Mini 20 / Point
±4kV
Contact Discharge
Pass
Mini 20 / Point
±8kV
Air Discharge
Pass
Mini 20 / Point
±4kV
Indirect Discharge HCP
Pass
Mini 20 / Point
±4kV
Indirect Discharge VCP
Pass
Note: For tested points to EUT, refer to the enclosed pages. Be aware that the Blue mark is for
contact discharge, and the red mark is for air discharge.
PERFORMANCE CRITERIA
Criteria requested
A/
B/
C
Criteria meet
A/
B/
C
Page 25
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
The Tested Points of EUT
Page 26
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
Page 27
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
Page 28
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
Page 29
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
7.6 RF ELECTROMAGNETIC FIELD
LIMIT
Please refer to EN 61000-4-3
Test Configuration
3 meter
7x3x3
EUT &
Support Units
1.5 meter
0.8m
Power Amp
Signal
Generator
PC Controller to
control S.G. & PA as
well as forward
power
EUT Monitoring by
using a camera
Control Room
Page 30
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
Ambient Condition of the Test Site
Temperature
23°C
EUT AC Voltage Rating
230 Vac, 50 Hz
Humidity
40%RH
EUT DC Voltage Rating
N/A
Pressure
1019 mbar
Ground Bond Resistance
0.2 Ω
Tested by
Tom Jen
TEST PROCEDURE
Please refer to ETSI EN 301 489-1 Clause 9.2.2, ETSI EN 301 489-17 Clause 7.2 and EN
61000-4-3 for the measurement methods.
TEST RESULTS
PASS (EUT continued to operate normally during test)
Description of Preliminary Test (Operating & Standby Modes)
Field
Modulation
Polarity
Position (°)
1
Freq. Range
(MHz)
80-2000
6V/m
Yes
H/V
Front
2
80-2000
6V/m
Yes
H/V
Right
3
80-2000
6V/m
Yes
H/V
Back
4
80-2000
6V/m
Yes
H/V
Left
Selection for
the final test
Result of Final Tests (Operating Mode)
Freq. Range
(MHz)
Field
Modulation
Polarity
Position (°)
Result
(Pass/Fail)
80-2000
3V/m
Yes
H/V
Front
Pass
PERFORMANCE CRITERIA
Criteria requested
A/
B/
C
Criteria meet
A/
B/
C
Results of Final Tests (Standby Mode)
Freq. Range
(MHz)
Field
Modulation
Polarity
Position (°)
Result
(Pass/Fail)
80-2000
3V/m
Yes
H/V
Front
Pass
PERFORMANCE CRITERIA
Criteria requested
A/
B/
C
Criteria meet
A/
B/
C
Page 31
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
7.7 AC MAINS FAST TRANSIENTS – COMMON MODE
LIMIT
Please refer to EN 61000-4-4
Test Configuration
EUT
AC Line
EFT/Burst/
Surge Generator
0.8m
Support Units
Non-Conductive Table
Controller Computer
Comm. Line ≧ 3 m
To Load
EUT
10cm
AC Line
Burst Generator
Injection Clamp
Non-Conductive
Table
0.8m
Ambient Condition of the Test Site
Temperature
23°C
EUT AC Voltage Rating
230 Vac, 50 Hz
Humidity
40%RH
EUT DC Voltage Rating
N/A
Pressure
1019 mbar
Ground Bond Resistance
0.2 Ω
Tested by
Tom Jen
Page 32
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
TEST PROCEDURE
Please refer to ETSI EN 301 489-1 Clause 9.4.2 and EN 61000-4-4 for the measurement methods.
TEST RESULTS
PASS (EUT continued to operate normally during test)
TEST CONDITIONS
Results of Final Tests (Operating Mode)
Impulse Frequency: 5 kHz
Tr/Th: 5/50ns
Burst Duration: 15ms
Burst Period: 3Hz
Injection Line
Voltage (kV) Injected Method
Line
±1
Direct
Neutral
±1
Direct
Direct
PE
±1
Line + Neutral
±1
Direct
Direct
L + PE
±1
Direct
N + PE
±1
Direct
L + N + PE
±1
RJ45 port (LAN cable)
±0.5
Clamp
RJ11 port (Line cable)
±0.5
Clamp
PERFORMANCE CRITERIA
Criteria requested
A/
B/
Criteria meet
A/
B/
Results of Final Tests (Standby Mode)
Impulse Frequency: 5 kHz
Tr/Th: 5/50ns
Burst Duration: 15ms
Burst Period: 3Hz
Injection Line
Voltage (kV)
Line
±1
Neutral
±1
PE
±1
Line + Neutral
±1
L + PE
±1
N + PE
±1
L + N + PE
±1
RJ45 port (LAN cable)
±0.5
RJ11 port (Line cable)
±0.5
C
C
Injected Method
Direct
Direct
Direct
Direct
Direct
Direct
Direct
Clamp
Clamp
PERFORMANCE CRITERIA
Criteria requested
A/
B/
Criteria meet
A/
B/
Page 33
Result (Pass / Fail)
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Result (Pass / Fail)
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
C
C
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
7.8 AC MAINS SURGE
LIMIT
Please refer to EN 61000-4-5
Test Configuration
To AC
Source
Surge Immunity
Test
EUT
&
Support Units
0.8m
Controller Computer
Ambient Condition of the Test Site
Temperature
Humidity
Pressure
Tested by
23°C
40%RH
1019 mbar
Tom Jen
EUT AC Voltage Rating
EUT DC Voltage Rating
Ground Bond Resistance
230 Vac, 50 Hz
N/A
0.2 Ω
TEST PROCEDURE
Please refer to ETSI EN 301 489-1 Clause 9.8.2 and EN 61000-4-5 for the measurement
methods.
Page 34
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
TEST RESULTS
PASS (EUT continued to operate normally during test)
Test conditions
Results of Final Tests (Operating Mode)
Voltage Waveform: 1.2/50 us
Current Waveform: 8/20 us
Polarity: Positive/Negative
Phase angle: 0o, 90o, 180 o, 270o
Coupling Line
Voltage (kV)
Polarity
Coupling Method Result (Pass/Fail)
Line + Neutral
1
Pos./ Neg.
Capacitive
Pass
L + PE
1
Pos./ Neg.
Capacitive
Pass
N + PE
1
Pos./ Neg.
Capacitive
Pass
T, R-Ground
0.5
Pos./ Neg.
Capacitive
Pass
L1, 2, 3, 4-G (LAN)
0.5
Pos./ Neg.
Capacitive
Pass
PERFORMANCE CRITERIA
Criteria requested
A/
B/
C
Criteria meet
A/
B/
C
Results of Final Tests (Standby Mode)
Voltage Waveform: 1.2/50 us
Current Waveform: 8/20 us
Polarity: Positive/Negative
Phase angle: 0o, 90o, 180 o, 270o
Coupling Line
Voltage (kV)
Polarity
Coupling Method Result (Pass/Fail)
Line + Neutral
1
Pos./ Neg.
Capacitive
Pass
L + PE
1
Pos./ Neg.
Capacitive
Pass
N + PE
1
Pos./ Neg.
Capacitive
Pass
T, R-Ground
0.5
Pos./ Neg.
Capacitive
Pass
L1, 2, 3, 4-G (LAN)
0.5
Pos./ Neg.
Capacitive
Pass
PERFORMANCE CRITERIA
Criteria requested
A/
B/
C
Criteria meet
A/
B/
C
Page 35
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
7.9 AC MAINS RF – COMMON MODE
LIMIT
Please refer to EN 61000-4-6
Test Configuration
0.1m< L <0.3m
10 cm isolation
supporter
EUT and
Support units
Power
Amplifier
CDN
PC
Controller
Ground Reference Plane
Ambient Condition of the Test Site
Temperature
23°C
EUT AC Voltage Rating
230 Vac, 50 Hz
Humidity
40%RH
EUT DC Voltage Rating
N/A
Pressure
1019 mbar
Ground Bond Resistance
0.2 Ω
Tested by
Tom Jen
Page 36
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
TEST PROCEDURE
Please refer to ETSIETSI EN 301 489-1 Clause 9.5.2, ETSI EN 301 489-17 Clause 7.2.2 and EN
61000-4-6 for the measurement methods.
TEST RESULTS
PASS (EUT continued to operate normally during test)
TEST CONDITIONS
Results of Final Tests (Operating Mode)
Frequency Range: 0.15MHz~80MHz
Frequency Step: 1% of fundamental
Dwell time: 3 Sec.
80% A.M., 1 kHz Sine wave (Field Strength: 3 V/m)
Coupling type:
CDN: FCC-801-M3-16A /
RF Current Probe
Range (MHz)
Field
Modulation
Result (Pass/Fail)
0.15-80
3V/m
Yes
Pass
PERFORMANCE CRITERIA
Criteria requested
A/
B/
C
Criteria meet
A/
B/
C
Results of Final Tests (Standby Mode)
Frequency Range: 0.15MHz~80MHz
Frequency Step: 1% of fundamental
Dwell time: 3 Sec.
80% A.M., 1 kHz Sine wave (Field Strength: 3 V/m)
Coupling type:
CDN: FCC-801-M3-16A /
RF Current Probe
Range (MHz)
Field
Modulation
Result (Pass/Fail)
0.15-80
3V/m
Yes
Pass
PERFORMANCE CRITERIA
Criteria requested
A/
B/
Criteria meet
A/
B/
C
C
Page 37
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
7.10 VOLTAGE DIPS AND INTERRUPTION
LIMIT
Please refer to EN 61000-4-11
Test Configuration
To AC
Source
Dips/Interruption
and Variations
Simulator
EUT
&
Support Units
0.8m
Controller Computer
Ambient Condition of the Test Site
Temperature
23°C
EUT AC Voltage Rating
230 Vac, 50 Hz
Humidity
40%RH
EUT DC Voltage Rating
N/A
Pressure
1019 mbar
Ground Bond Resistance
0.2 Ω
Tested by
Tom Jen
TEST PROCEDURE
Please refer to ETSI EN 301 489-1 Clause 9.7.2 and EN 61000-4-11 for the measurement
methods.
Page 38
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
TEST RESULTS
PASS (for criteria A: EUT continued to operate normally during test)
(for criteria B: EUT shut down, but can be auto recovered as the events disappear.)
(for criteria C: EUT shut down, but can be recovered by manual, as the events disappear.)
TEST CONDITIONS
Interruption at phase angles of 0, 45, 90, 135, 180, 225, 270 and 315 degree in a 10
sec-interval.
Test Level
(% UT)
Reduction
(%)
Duration
(ms)
Criterion
70
30%
10
B
40
60%
100
C
<5
>95%
5000
C
Voltage
Dips
Voltage
Interruption
Note: The duration with a sequence of three dips/interruptions with a minimum interval of 10 s
between each test event.
Results of Final Tests (Operating Mode)
Voltage Dips
Test Level
(% UT)
Reduction
(%)
Duration
(ms)
Observation
Criterion
70
30
10
Normal
A
40
60
100
Normal
B
Voltage Interruption
Test Level
(% UT)
Reduction
(%)
Duration
(ms)
Observation
Criterion
<5
95
5000
Normal
C
Results of Final Tests (Standby Mode)
Voltage Dips
Test Level
(% UT)
Reduction
(%)
Duration
(ms)
Observation
Criterion
70
30
10
Normal
A
40
60
100
Normal
B
Voltage Interruption
Test Level
(% UT)
Reduction
(%)
Duration
(ms)
Observation
Criterion
<5
95
5000
Normal
C
Page 39
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
APPENDIX 1
PHOTOGRAPHS OF TEST SETUP
RADIATED EMISSION TEST (EN 55022)
Page 40
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
LINE CONDUCTED EMISSION TEST (EN 55022)
Page 41
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
POWER HARMONICS &VOLTAGE FLUCTUATION / FLICKER
(EN 61000-3-2/EN 61000-3-3)
Page 42
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
ELECTROSTATIC DISCHARGE TEST (EN 61000-4-2)
RADIATED ELECTROMAGNETIC FIELD (EN 61000-4-3)
Page 43
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
FAST TRANSIENTS/BURST TEST (EN 61000-4-4)
SURGE IMMUNITY TEST (EN 61000-4-5)
Page 44
Rev.00
Compliance Certification Services Inc.
Report No: 41104402-RE
Date of Issue: December 7, 2004
CONDUCTED DISTURBANCE, INDUCED BY RADIO-FREQUENCY
FIELDS TEST (EN 61000-4-6)
VOLTAGE DIPS/ INTERRUPTION TEST (EN 61000-4-11)
Page 45