Multiswitches

Transcription

Multiswitches
Multiswitches
| TMS, THA & TMM series
Multiswitches
TMU Unicable series
TMS 17xC and 17xT series
TMS 13xC and 13xT series
TMS 9xC series
TMS 5xC series
TMS 2xC/ TMS 5x series
TMM 5x cascadable
TMM 5x terminated
TMM 4x cascadable
TMS 9xP series
Multi
switches
TMS 5xP series
TMP 9x series
TMP 5x series
TMPR 5 seriesx
TMS 55 tap/TMM splitter
TMS amplifiers
TMM launch amplifiers
THA 340E/TLA 340E amplifiers
TMS power supplies
TMM/TMS accessories
TRIAX | 192
Multiswitches
| TMU Unicable Cascade
The Unicable multiswitch is cascadable
and suitable for all common Quatro LNBs
and secures unlimited reception of programs
transmitted by a satellite. Moreover, there
is a second output for connection of an
additional receiver in standard LNB mode.
• Feeding of all existing satellite transponders
including not yet occupied frequencies.
• Cascadable and HDTV-compatible
• Complies with the Unicable standard
• 4 SAT inputs + one terrestrial input
• Extra output for connection of an
additional receiver in standard mode.
• SAT range with 10 dB gain.
• Superflat housing
• Power supply included
Technical data
Type:
Art. No:
Multi
switches
Number of inputs
Insertion loss - trunkline TER
Insertion loss - trunkline SAT
Subscriber outputs
Frequency range SAT
Frequency range TER
Slope control TER
Input polarity gain control SAT
Input polarity gain control TER
Isolation SAT to TER
Isolation TER to SAT
Isolation cross polarisation H/V
Isolation out-out SAT
Isolation out-out TER
Return loss SAT inputs
Return loss SAT outputs
Return loss TER inputs
Return loss TER outputs
Output level SAT @ -35 dB IMD3
Output level TER @ 60dB IMD3
LNB current max.
Line power voltage (TER)
Line power current (TER)
Switch commands
Supply voltage
Power supply
Power supply current
Connectors
Colourcoding of IF and TER inputs
Temperature range
Dimensions (H x D x W)
193 | TRIAX
TMU 518
Unicable
307330
TMU 918
Unicable
389049
4 SAT, 1 TER
4 SAT, 1 TER
dB
3.0
3.0
dB
3.0
3.0
pcs.
4
4
MHz
950-2150
950-2150
MHz
47-862
47-862
dB
10.0
10.0
dB
4 X 10.0
4 X 10.0
dB
15.0
15.0
dB
32
32
dB
32
32
dB
30
30
dB
30
30
dB
30
30
dB
10
10
dB
8
8
dB
10
10
dB
8
8
dBµV
100
100
dBµV
95
95
mA
600
600
V
12.0
12.0
mA
50.0
50.0
V/kHz 13V/18V - 13V/22 kHz - 18V/22 kHz 13V/18V - 13V/22 kHz - 18V/22 kHz
V/DC
18.0
18.0
VAC
180-264
180-264
A
1.5 (47-63 HZ)
1.5 (47-63 HZ)
F-female
F-female
Ja
Ja
degrees
0...+55
0...+55
157 x 51 x 190
157 x 51 x 190
Multiswitches
| TMS 17xC Cascade
Triax TMS 17x series is an easy-to-install
multiswitch system for use where 4 satellite positions are required. A terrestrial
input is available to allow terrestrial as
well as satellite signals to be available
on all subscriber outputs. TMS 17x has
an active satellite signal path and a
passive terrestrial signal path allowing a
terrestrial return path if needed. Satellite
position switching is done via DiSEqC
signals from the subscriber set-top box.
Technical data
TMS 17x6C
Terminated
301506
Art. No:
Number of inputs
Insertion loss - trunkline TER
Insertion loss - trunkline SAT
Number of outputs
Subscriber outputs
Frequency range SAT
Frequency range TER
Gain - SAT [950-2150 MHz]
Gain - TER [47-862 MHz]
Isolation LNB to LNB
Isolation SAT to TER
Isolation TER to SAT
Isolation cross polarisation H/V
Isolation out-out SAT
Isolation out-out TER
Return loss SAT inputs
Return loss SAT outputs
Return loss TER inputs
Return loss TER outputs
Output level SAT @ -35 dB IMD3
LNB power supply max.
Impedance input/output
Switching voltage
Supply voltage
Power supply
Power link (for amplifiers in line)
Connectors
Control LEDs
Colourcoding - IF and TER inputs
Temperature range
Dimensions (H x D x W)
TMS 17x8C
Cascadable
301508
TMS 17x12C
Cascadable
301512
TMS 17x16C
Cascadable
301516
pcs.
dB
dB
pcs.
pcs.
MHz
MHz
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dBµV
A
Ohm
16 SAT, 1 TER
16 SAT, 1 TER
16 SAT, 1 TER
16 SAT, 1 TER
4.0
4.0
4.0
4.0
3.0
3.0
4.0
4.0
16 SAT, 1 TER
16 SAT, 1 TER
16 SAT, 1 TER
16 SAT, 1 TER
6
8
12
16
950-2150 (active)
950-2150 (active)
950-2150 (active)
950-2150 (active)
5-862 (passive)
5-862 (passive)
5-862 (passive)
5-862 (passive)
0.0
0.0
- 2.0
- 2.0
- 24.0
- 24.0
- 27.0
- 27.0
35.0
30.0
35.0
35.0
30.0
30.0
30.0
30.0
20.0
20.0
20.0
20.0
28.0
28.0
28.0
28.0
30.0
30.0
30.0
30.0
25.0
25.0
25.0
25.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
100
100
100
100
1.3
1.3
1.3
1.3
75
75
75
75
13V-18V - 13V/22kHz 13V-18V - 13V/22kHz 13V-18V - 13V/22kHz 13V-18V - 13V/22kHz
18V/22kHz
18V/22kHz
18V/22kHz
18V/22kHz
DiSEqC 2.0
DiSEqC 2.0
DiSEqC 2.0
DiSEqC 2.0
Toneburst
Toneburst
Toneburst
Toneburst
V/DC
15.0 (± 0.5)
15.0 (± 0.5)
15.0 (± 0.5)
15.0 (± 0.5)
External
External
External
External
Yes
Yes
Yes
Yes
F-female
F-female
F-female
F-female
Green for power,
Green for power,
Green for power,
Green for power,
Yellow for power link Yellow for power link Yellow for power link Yellow for power link
Yes
Yes
Yes
degrees
0...+55
0...+55
0...+55
125 x 55 x 355
125 x 55 x 355
215 x 55 x 355
215 x 55 x 355
TRIAX | 194
Multi
switches
Type:
Multiswitches
| TMS 17xT Terminated
Triax TMS 17x Multiswitches 16 polarities (4 positions + 1 ter.)
Triax TMS 17x series is an easy-to-install
multiswitch system for use where 4 satellite positions are required. A terrestrial
input is available to allow terrestrial as
well as satellite signals to be available
on all subscriber outputs. TMS 17x has
an active satellite signal path and a
passive terrestrial signal path allowing a
terrestrial return path if needed. Satellite
position switching is done via DiSEqC
signals from the subscriber set-top box.
Technical data
Type:
Art. No:
Multi
switches
Number of inputs
Number of outputs
Subscriber outputs
Frequency range SAT
Frequency range TER
Gain - SAT [950-2150 MHz]
Gain - TER [47-862 MHz]
Isolation LNB to LNB
Isolation SAT to TER
Isolation TER to SAT
Isolation cross polarisation H/V
Isolation out-out SAT
Isolation out-out TER
Return loss SAT inputs
Return loss SAT outputs
Return loss TER inputs
Return loss TER outputs
Output level SAT @ -35 dB IMD3
LNB power supply max.
Impedance input/output
Switching voltage
Supply voltage
Power supply
Power link (for amplifiers in line)
Connectors
Control LEDs
Colourcoding - IF and TER inputs
Temperature range
Dimensions (H x D x W)
195 | TRIAX
TMS 17x6T
Terminated
301606
TMS 17x8T
Terminated
301608
TMS 17x12T
Terminated
301612
TMS 17x16T
Terminated
301616
pcs.
16 SAT, 1 TER
16 SAT, 1 TER
16 SAT, 1 TER
16 SAT, 1 TER
pcs.
16 SAT, 1 TER
16 SAT, 1 TER
16 SAT, 1 TER
16 SAT, 1 TER
pcs.
6
8
12
16
MHz 950-2150 (active)
950-2150 (active)
950-2150 (active)
950-2150 (active)
MHz 5-862 (passive)
5-862 (passive)
5-862 (passive)
5-862 (passive)
dB
- 2.0
0.0
- 2.0
0.0
dB
- 21.0
- 22.0
- 24.0
- 24.0
dB
35.0
35.0
35.0
35.0
dB
30.0
30.0
30.0
30.0
dB
20.0
20.0
20.0
20.0
dB
28.0
28.0
28.0
28.0
dB
30.0
30.0
30.0
30.0
dB
25.0
25.0
25.0
25.0
dB
12.0
12.0
12.0
12.0
dB
12.0
12.0
12.0
12.0
dB
8.0
8.0
8.0
8.0
dB
8.0
8.0
8.0
8.0
dBµV
100
100
100
100
A
1.3
1.3
1.3
1.3
Ohm
75
75
75
75
13V-18V - 13V/22kHz 13V-18V - 13V/22kHz 13V-18V - 13V/22kHz 13V-18V - 13V/22kHz
18V/22kHz
18V/22kHz
18V/22kHz
18V/22kHz
DiSEqC 2.0
DiSEqC 2.0
DiSEqC 2.0
DiSEqC 2.0
Toneburst
Toneburst
Toneburst
Toneburst
V/DC
15.0 (± 0.5)
15.0 (± 0.5)
15.0 (± 0.5)
15.0 (± 0.5)
External
External
External
External
Yes
Yes
Yes
Yes
F-female
F-female
F-female
F-female
Green for power,
Green for power,
Green for power,
Green for power,
Yellow for power link Yellow for power link Yellow for power link Yellow for power link
Yes
Yes
Yes
Yes
degrees
0...+55
0...+55
0...+55
0...+55
125 x 55 x 355
125 x 55 x 355
215 x 55 x 355
215 x 55 x 355
Multiswitches
| TMS 13xC Cascade & 13xT Terminated
Triax TMS 13x Multiswitches 12 polarities (3 positions + 1 ter.)
Triax TMS 13x series is an active and
cascadable SAT-IF multi switch series
for 3 SAT positions (12 SAT polarities
+ terrestrial) in versions with 8 to 24
subscriber outputs.Suitable for analogue
and digital reception.
Technical data
Art. No:
TMS 13x8C
Cascadable
307408
TMS 13x12C
Cascadable
307412
TMS 13x16C
Cascadable
307416
TMS 13x24C
Cascadable
307424
TMS 13x12T
Terminated
307417
Number of inputs
Insertion loss - trunkline TER
Insertion loss - trunkline SAT
Number of outputs
Subscriber outputs
Frequency range SAT
pcs. 12 SAT, 1 TER
12 SAT, 1 TER
12 SAT, 1 TER
12 SAT, 1 TER
12 SAT, 1 TER
6.0 (± 1.0)
6.0 (± 1.0)
6.0 (± 1.0)
10.0 (± 1.0)
dB
7.0 (± 2.0)
7.0 (± 2.0)
7.0 (± 2.0)
10.0 (± 1.0)
dB
12 SAT, 1 TER
12 SAT, 1 TER
12 SAT, 1 TER
12 SAT, 1 TER
pcs. 12 SAT, 1 TER
12
12
16
24
pcs.
MHz
950-2150
950-2150
950-2150
950-2150
950-2150
(active)
(active)
(active)
(active)
(active)
Frequency range TER
MHz 5-862 (85 to 862 5-862 (85 to 862 5-862 (85 to 862 5-862 (85 to 862 5-862 (85 to 862
MHz with active MHz with active MHz with active MHz with active MHz with active
return path)
return path)
return path)
return path)
return path)
Return path TER
MHz
5 to 65
5 to 65
5 to 65
5 to 65
5 to 65
(switchable on/off) (switchable on/off) (switchable on/off) (switchable on/off) (switchable on/off)
- 2.0 ... + 4.0
- 2.0 ... + 4.0
- 4.0 ... + 4.0
Gain - SAT [950-2150 MHz]
dB - 2.0 ... + 4.0
18.0...24.0 (± 2.0)
Gain - TER [47-862 MHz]
dB - 2.0 ... + 4.0
- 2.0 ... + 4.0
- 2.0 ... + 4.0
- 4.0 ... + 4.0
17.0 (± 2.0)
Attenuation SAT
0 - 10.0
Attenuation TER
0 - 10.0
Equalization SAT
0-6,0 (switchable)
Equalization TER
0 - 15.0
Noise figure SAT
< 8.0
Noise figure TER
< 5.0
Isolation cross polarisation H/V
dB
> 28.0
> 28.0
> 28.0
> 28.0
> 28.0
Isolation out-out SAT
dB
> 30.0
> 30.0
> 30.0
> 30.0
> 30.0
Return loss
dB > 10.0 (all ports) > 10.0 (all ports) > 10.0 (all ports) > 10.0 (all ports) > 10.0 (all ports)
Output level SAT @ -35 dB IMD3 dBµV
95
95
95
95
110
Output level TER @ 60dB IMD3
dBµV
85
85
85
85
105
Impedance input/output
Ohm
75
75
75
75
75
Switching voltage
V/DC
Ver. 13.0/
Ver. 13.0/
Ver. 13.0/
Ver. 13.0/
Ver. 13.0/
Hor. 17.5 (± 1.0) Hor. 17.5 (± 1.0) Hor. 17.5 (± 1.0) Hor. 17.5 (± 1.0) Hor. 17.5 (± 1.0)
Supply voltage
V/DC
18.0 (± 0.5)
18.0 (± 0.5)
18.0 (± 0.5)
18.0 (± 0.5)
18.0 (± 0.5)
Power supply
External
External
External
External
External
Power supply current
mA
1600
1600
1600
1600
1600
Connectors
F-female
F-female
F-female
F-female
F-female
Colourcoding - IF and TER inputs
Yes
Yes
Yes
Yes
Yes
Temperature range
deg.
0...+55
0...+55
0...+55
0...+55
0...+55
Dimensions (H x D x W)
202 x 53 x 334 202 x 53 x 334 246 x 53 x 334 340 x 53 x 334 163 x 53 x 334
TRIAX | 196
Multi
switches
Type:
Multiswitches
| TMS 9xC Cascade
Triax TMS 9x Multiswitches 8 polarities (2 positions + 1 ter.)
For two satellite positions in smaller
networks the Triax TMS 9X series is
the right choice. For easy installation
all inputs are coloured identical to Triax
multicable colours. All multiswitches
have integrated loop-in of VHF/UHF.
Technical data
Type:
Art. No:
Multi
switches
Number of inputs
Insertion loss - trunkline TER
Insertion loss - trunkline SAT
Number of outputs
Subscriber outputs
Frequency range SAT
Frequency range TER
Return path TER
Gain - SAT (with 5 dB slope)
Gain - TER (47-862 MHz)
Isolation LNB to LNB
Isolation SAT to TER
Isolation TER to SAT
Isolation cross polarisation H/V
Isolation out-out SAT
Isolation out-out TER
Return loss SAT inputs
Return loss SAT outputs
Return loss TER inputs
Return loss TER outputs
Output level SAT @ -35 dB IMD3
Output level TER @ 60dB IMD3
Impedance input/output
Switching
TMS 9x4C
Cascadable
300364
TMS 9x6C
Cascadable
300366
TMS 9x8C
Cascadable
300368
TMS 9x12C
Cascadable
300372
TMS 9x16C
Cascadable
300376
pcs. 8 SAT, 1 TER
8 SAT, 1 TER
8 SAT, 1 TER
8 SAT, 1 TER
8 SAT, 1 TER
dB
4.0 (± 1.0)
4.0 (± 1.0)
5.0 (± 1.0)
5.0 (± 1.0)
5.0 (± 1.0)
dB
2.0 (± 2.0)
3.0 (± 2.0)
4.0 (± 2.0)
4.0 (± 2.0)
4.0 (± 2.0)
pcs. 8 SAT, 1 TER
8 SAT, 1 TER
8 SAT, 1 TER
8 SAT, 1 TER
8 SAT, 1 TER
pcs.
4
6
8
8
16
MHz 950-2150 (active) 950-2150 (active) 950-2150 (active) 950-2150 (active) 950-2150 (active)
MHz 5-862 (active)
5-862 (active)
5-862 (active)
5-862 (active)
5-862 (active)
5-65 (passive)
5-65 (passive)
5-65 (passive)
5-65 (passive)
dB -3.0 to 2.0 (± 1.0) -3.0 to 2.0 (± 1.0) -3.0 to 2.0 (± 1.0)
-3.0
-3.0
dB
- 9.0
- 9.0
- 9.0
- 9.0
- 9.0
dB
35
35
35
35
35
dB
28
28
28
28
28
dB
23
23
23
23
23
dB
28
28
28
28
28
dB
30
30
30
30
30
dB
28
28
28
28
28
dB
13
13
13
13
13
dB
8
8
8
8
8
dB
11
11
11
11
11
dB
8
8
8
8
8
dBµV
100
100
100
100
100
dBµV
88
88
88
88
88
Ohm
75
75
75
75
75
V/DC
14V/18V
14V/18V
14V/18V
14V/18V
14V/18V
14V/22kHz
14V/22kHz
14V/22kHz
14V/22kHz
14V/22kHz
18V/22kHz
18V/22kHz
18V/22kHz
18V/22kHz
18V/22kHz
DiSEqC 2.0
DiSEqC 2.0
DiSEqC 2.0
DiSEqC 2.0
DiSEqC 2.0
Supply voltage
V/DC
15.0 (± 1.0)
15.0 (± 1.0)
15.0 (± 1.0)
15.0 (± 1.0)
15.0 (± 1.0)
Power supply
External
External
External
External
External
Max. current pass per F-con.
mA
500
500
500
500
500
Connectors
F-female
F-female
F-female
F-female
F-female
Colourcoding - IF and TER inputs
Yes
Yes
Yes
Yes
Yes
Temperature range
deg.
0...+55
0...+55
0...+55
0...+55
0...+55
Dimensions (H x D x W)
124 x 51 x 253 124 x 51 x 253 152 x 51 x 253 210 x 51 x 257 210 x 51 x 257
197 | TRIAX
Multiswitches
| TMS 5xC Cascade, ext. PSU
Triax TMS 5x Multiswitches 4 polarities (2 positions + 1 ter.)
Suitable for building custom cascade
system using TMS 55 TAP units and
external power supply.
Technical data
Art. No:
Number of inputs
pcs.
Subscriber outputs
Frequency range SAT
Frequency range TER
pcs.
MHz
MHz
Return path TER
Through loss - Trunk SAT
Through loss - Trunk TER
Gain - SAT [950-2150 MHz]
Gain - TER [47-862 MHz]
Input polarity gain control SAT
Isolation cross polarisation H/V
Isolation out-out SAT
Return loss SAT inputs
Return loss SAT outputs
Return loss TER inputs
Return loss TER outputs
Return loss TAP outputs
Impedance input/output
Switching
MHz
Supply voltage
Max. current
Connectors
Colourcoding of IF and TER inputs
Temperature range
Dimensions (H x D x W)
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
Ohm
V/DC
V/DC
mA
degrees
TMS 5X6
Cascadable
TMS 5X8
Cascadable
307456
307458
4 SAT, 1 TER
4 SAT, 1 TER
Multi
switches
Type:
6
8
950-2150
950-2150
5-862 / 85 to 862MHz
5-862 / 85 to 862MHz
with passive return path with passive return path
5-65
5-65
4.0 (± 1.0)
7.0 (± 1.0)
4.0 (± 1.0)
6.0 (± 1.0)
-2.0 ... +4.0
-2.0 ... +4.0
-2.0 ... +4.0
-2.0 ... +4.0
0, 6, 12 or 6...12
0, 6, 12 or 6...12
> 28.0
> 28.0
> 30.0
> 30.0
> 10.0
> 10.0
> 10.0
> 10.0
> 10.0
> 10.0
> 10.0
> 10.0
> 10.0
> 10.0
75
75
13V (± 1.0)/
13V (± 1.0)/
17.5V (± 1.0)
17.5V (± 1.0)
18.0 (± 1.0)
18.0 (± 1.0)
350
350
F-female
F-female
Yes
Yes
0...+55
0...+55
150 x 45 x 182
150 x 45 x 182
TRIAX | 198
Multiswitches
| TMS 2xC Cascade & TMS 5x Single, ext. PSU
TMS 2x Multiswitches
2 polarities (1 SAT position), no TER.
Cascadable system for many users.
Simple and easy to install. For external
power supply.
Triax TMS 5x Multiswitches
4 polarities (2 positions + 1 ter.)
Suitable for building custom cascade
system using TMS 55 TAP units and
external power supply.
Technical data
Type:
Art. No:
Multi
switches
Number of inputs
Insertion loss - trunkline SAT
Subscriber outputs
Frequency range SAT
Frequency range TER
Gain - SAT [950-2150 MHz]
Gain - TER [47-862 MHz]
Noise figure SAT
Isolation LNB to LNB
Isolation trunk to trunk
Isolation SAT to TER
Isolation TER to SAT
Isolation cross polarisation H/V
Isolation out-out SAT
Isolation out-out TER
Return loss SAT inputs
Return loss SAT outputs
Return loss TER inputs
Return loss TER outputs
Return loss TAP outputs
Output level SAT @ -35 dB IMD3
Output level TER @ 60dB IMD3
Impedance input/output
Switching
pcs.
dB
pcs.
MHz
MHz
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dBµV
dBµV
Ohm
V/DC
Supply voltage
Power supply
Max. current @ 13 V/18V
Max. current to each H/V LNB
Max. current pass per F-connector
Input voltage
Connectors
Colourcoding of IF and TER inputs
Temperature range
Dimensions (H x D x W)
V/DC
199 | TRIAX
kg
mA
mA
dBµV
degrees
TMS 2X4C
Cascadable
300274
TMS 2X8C
Cascadable
300278
TMS 5X4
Single
300314
2 SAT
3.5
4
950-2150
2 SAT
4.0
8
950-2150
4 SAT, 1 TER
- 2.0
- 2.0
6.0
30
40
6.0
30
40
30
30
12
12
12
12
10
100
10
100
75
13V/18V - 13V/22kHz
18V/22kHz
10.0 - 18.0
External
< 80
< 500
75
13V/18V - 13V/22kHz
18V/22kHz
10.0 - 18.0
External
< 80
< 500
40-90
F-female
Yes
-20...+60
90 x 51 x 80
40-90
F-female
Yes
-20...+60
90 x 51 x 80
4
950-2150
47-862
- 6.0
4.0
22
22
25
30
30
12
7
11
7
100
88
75
13V/18V - 13V/22kHz
18V/22kHz
15.0 (± 1.0)
External
600
F-female
Yes
0...+55
103 x 51 x 145
Multiswitches
| TMM 5x Cascade
TMM 5x cascadable multiswitches
- few to many users.
4 satellite polarities and 1 TERrestrial
input, combined output. Wide range of
launch and line amplifiers available
Technical data
TMM 5x4
Cascadable
305314
Art. No:
Number of inputs
Max. input level - SAT (IMD3 - 35dB)
Max. input level - TER (IMD3 - 60dB)
Number of outputs
Subscriber outputs
Frequency range SAT
Tap loss SAT
Tap loss TER
Through loss - Trunk SAT
Through loss - Trunk TER
Input polarity gain control SAT
Input polarity gain control TER
Noise figure SAT
Isolation SAT to TER
Isolation TER to SAT
Isolation cross polarisation H/V
Isolation out-out SAT
Isolation out-out TER
Return loss SAT inputs
Return loss SAT outputs
Return loss TER inputs
Return loss TER outputs
Return loss switch out - SAT
Return loss switch out - TER
Output level SAT @ -35 dB IMD3
Output level TER @ 60dB IMD3
Line power voltage (TER)
Switch commands
Supply voltage
Power supply current
Power connector
Max. current - each output
Connectors
Through voltage TER
Colourcoding of IF and TER inputs
Temperature range
Dimensions (H x D x W)
pcs.
dBµV
dBµV
pcs.
pcs.
MHz
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dBµV
dBµV
V/mA
V/DC
mA
mA
mA
deg.
TMM 5x8
Cascadable
305318
TMM 5x12
Cascadable
305312
TMM 5x16
Cascadable
305316
4 x SAT, 1 x TERR 4 x SAT, 1 x TERR 4 x SAT, 1 x TERR 4 x SAT, 1 x TERR
117.0
117.0
119.0
119.0
110.0
107.0
109.0
109.0
4 x SAT, 1 x TERR 4 x SAT, 1 x TERR 4 x SAT, 1 x TERR 4 x SAT, 1 x TERR
4
8
12
16
950-2150
950-2150
950-2150
950-2150
10.0
10.0
12.0
12.0
10.0
10.0
12.0
12.0
1.5
2.5
2.5
2.5
1.5
2.5
3.0
3.0
4 x 12.0
4 x 12.0
4 x 12.0
4 x 12.0
1 x 12.0
1 x 12.0
1 x 12.0
1 x 12.0
< 8.0
< 8.0
< 8.0
< 8.0
35.0
35.0
30.0
30.0
35.0
35.0
30.0
30.0
30.0
30.0
28.0
28.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
10.0
95.0
95.0
95.0
95.0
88.0
88.0
88.0
88.0
12.0/50.0
12.0/50.0
12.0/50.0
12.0/50.0
13V/18V - 13V-22kHz - 18V-22kHz - DiSEqC 2.0
15.0 (± 1.0)
15.0 (± 1.0)
15.0 (± 1.0)
15.0 (± 1.0)
< 15.0
< 15.0
< 15.0
< 15.0
2 x 1.3
2 x 1.3
2 x 1.3
2 x 1.3
< 150.0
< 150.0
< 150.0
< 150.0
F-female
F-female
F-female
F-female
50
50
50
50
Yes
Yes
Yes
Yes
0...50
0...50
0...50
0...50
130 x 140 x 38
220 x 140 x 38
220 x 140 x 38
220 x 140 x 38
TRIAX | 200
Multi
switches
Type:
Multiswitches
| TMM 5x Terminated
TMM 5x cascadable multiswitches
- few to many users.
4 satellite polarities and 1 TERrestrial
input, combined output. Wide range of
launch and line amplifiers available
Technical data
Type:
TMM 5x12
Terminated
305317
Art. No:
Multi
switches
Number of inputs
Max. input level - SAT (IMD3 - 35dB)
Max. input level - TER (IMD3 - 60dB)
Number of outputs
Subscriber outputs
Frequency range SAT
Tap loss SAT
Tap loss TER
Through loss - Trunk SAT
Through loss - Trunk TER
Input polarity gain control SAT
Input polarity gain control TER
Noise figure SAT
Isolation SAT to TER
Isolation TER to SAT
Isolation cross polarisation H/V
Isolation out-out SAT
Isolation out-out TER
Return loss SAT inputs
Return loss SAT outputs
Return loss TER inputs
Return loss TER outputs
Return loss switch out - SAT
Return loss switch out - TER
Output level SAT @ -35 dB IMD3
Output level TER @ 60dB IMD3
Line power voltage (TER)
Switch commands
Supply voltage
Power supply current
Power connector
Max. current - each output
Connectors
Through voltage TER
Colourcoding of IF and TER inputs
Temperature range
Dimensions (H x D x W)
201 | TRIAX
pcs.
dBµV
dBµV
pcs.
pcs.
MHz
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dBµV
dBµV
V/mA
V/DC
mA
mA
mA
deg.
4 x SAT, 1 x TERR
119.0
109.0
4 x SAT, 1 x TERR
12
950-2150
12.0
12.0
2.5
3.0
4 x 12.0
1 x 12.0
< 8.0
30.0
30.0
28.0
30.0
30.0
12.0
12.0
12.0
12.0
10.0
10.0
95.0
88.0
12.0/50.0
13V/18V - 13V-22kHz - 18V-22kHz - DiSEqC 2.0
15.0 (± 1.0)
< 15.0
2 x 1.3
< 150.0
F-female
50
Yes
0...50
220 x 140 x 38
Multiswitches
| TMM 4x Cascade
TMM 5x cascadable multiswitches
- few to many users.
4 satellite polarities, 1 SAT position.
Versions for 8, 12 and 16 subscriber
outputs. Adjustable attenuator per
polarity (0-12 dB). L
ow power consumption. Small footprint,
compact design, fits into tight spaces.
2-, 3- and 4-way DiSEqC bridger units
with TER loop-through available to
expand a one-position TMM system
into a full 2-, 3-, or 4-satellite position
reception system. Wide range of launch
and line amplifiers available
Type:
TMM 4x4
Cascadable
305324
TMM 4x8
Cascadable
305328
TMM 4x12
Cascadable
305322
TMM 4x16
Cascadable
305326
pcs.
4 x SAT
4 x SAT
4 x SAT
4 x SAT
Max. input level - SAT (IMD3 35dB)
dBµV
117.0
117.0
119.0
119.0
Insertion loss - trunkline SAT
Number of outputs
Subscriber outputs
Frequency range SAT
Tap loss SAT
Input polarity gain control SAT
Noise figure SAT
Isolation cross polarisation H/V
Isolation out-out SAT
Return loss SAT inputs
Return loss SAT outputs
Return loss TAP outputs
Output level SAT @ -35 dB IMD3
Switch commands
Switching voltage
Supply voltage
Supply voltage from receiver
Power supply current
Power connector
External power supply
Max. current to each output
(supplied by set top box)
dB
pcs.
pcs.
MHz
dB
dB
dB
dB
dB
dB
dB
dB
dBµV
Art. No:
Number of inputs
Connectors
Colourcoding of IF and TER inputs
Temperature range
Dimensions (H x D x W)
V
V/DC
mA
mA
mA
deg.
1.5
2.5
2.5
2.5
4 x SAT
4 x SAT
4 x SAT
4 x SAT
4
8
12
16
950-2150
950-2150
950-2150
950-2150
10.0
10.0
12.0
12.0
4 x 12.0
4 x 12.0
4 x 12.0
4 x 12.0
< 8.0
< 8.0
< 8.0
< 8.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
10.0
10.0
10.0
10.0
95.0
95.0
95.0
95.0
13V/18V - 13V-22 kHz - 18V-22 kHz
13V/18V - 13V-22 kHz - 18V-22 kHz
15.0 (± 1.0)
15.0 (± 1.0)
15.0 (± 1.0)
15.0 (± 1.0)
15.0 (± 1.0)
15.0 (± 1.0)
15.0 (± 1.0)
15.0 (± 1.0)
< 90.0
< 90.0
< 90.0
< 90.0
< 15.0
< 15.0
< 15.0
< 15.0
2 x 1.3
2 x 1.3
2 x 1.3
2 x 1.3
NO (DC on all 4 trunk lines via power inserter or amplifier)
< 150.0
< 150.0
< 150.0
< 150.0
F-female
Yes
0...50
220 x 140 x 38
F-female
Yes
0...50
220 x 140 x 38
F-female
Yes
0...50
220 x 140 x 38
F-female
Yes
0...50
220 x 140 x 38
TRIAX | 202
Multi
switches
Technical data
Multiswitches
| TMS 9xP Single w/PSU
TMS single/stand alone multi switch
solutions - 4 to 16 users
- offer a flexible and cost efficient system for providing one or two position
satellite reception and distribution in
small and medium sized networks. Low
power consumption.
Technical data
Type:
Art. No:
TMS 9x4P
Stand alone
300344
Multi
switches
Number of inputs
pcs. 8 SAT, 1 TER
Number of outputs
pcs. 8 SAT, 1 TER
4
Subscriber outputs
pcs.
Frequency range SAT
MHz
950-2150
Frequency range TER
MHz
47-862
Gain - SAT [950-2150 MHz]
dB
2.0
Gain - TER [47-862 MHz]
dB
- 2.0
Isolation SAT to TER
dB
30
Isolation TER to SAT
dB
28
Isolation cross polarisation H/V
dB
28
Isolation out-out SAT
dB
30
Isolation out-out TER
dB
26
Return loss SAT inputs
dB
14
Return loss SAT outputs
dB
7
Return loss TER inputs
dB
11
Return loss TER outputs
dB
8
Output level SAT @ -35 dB IMD3 dBµV
100
Output level TER @ 60dB IMD3
dBµV
85
Impedance input/output
Ohm
75
Switching
V/DC
Supply voltage
V/DC
15.0 (± 1.0)
Power supply
Included
Max. current pass
mA
1000
per F-connector
Connectors
F-female
Colourcoding of IF and
Yes
TER inputs
Temperature range
deg.
0...+55
Dimensions (H x D x W)
103 x 71x 359
203 | TRIAX
TMS 9x6P
Stand alone
300346
TMS 9x8P
Stand alone
300348
TMS 9x12P
Stand alone
300342
TMS 9x16P
Stand alone
300347
8 SAT, 1 TER
8 SAT, 1 TER
8 SAT, 1 TER
8 SAT, 1 TER
8 SAT, 1 TER
8 SAT, 1 TER
6
8
12
950-2150
950-2150
950-2150
47-862
47-862
47-862
2.0
2.0
0.0
- 2.0
- 2.0
4.0
30
30
30
28
28
30
28
28
25
30
30
30
26
26
28
14
14
10
7
7
10
11
11
12
8
8
10
100
100
100
85
85
83
75
75
75
13V/18V - 13V/22kHz - 18V/22kHz - DiSEqC 2.0
15.0 (± 1.0)
15.0 (± 1.0)
15.0 (± 1.0)
Included
Included
Included
1000
1000
1000
8 SAT, 1 TER
8 SAT, 1 TER
16
950-2150
47-862
0.0
2.0
28
30
25
30
30
10
10
12
10
100
82
75
15.0 (± 1.0)
Included
1000
F-female
Yes
F-female
Yes
F-female
Yes
F-female
Yes
0...+55
103 x 71x 359
0...+55
103 x 71x 359
0...+55
103 x 71x 459
0...+55
103 x 71x 559
Multiswitches
| TMS 5xP Single w/PSU
TMS single/stand alone multi switch
solutions - 4 to 16 users
- offer a flexible and cost efficient system for providing one or two position
satellite reception and distribution in
small and medium sized networks. Low
power consumption.
Type:
Art. No:
TMS 5x4P
Stand alone
300324
Number of inputs
pcs. 4 SAT, 1 TER
Number of outputs
pcs. 4 SAT, 1 TER
Subscriber outputs
pcs.
4
Frequency range SAT
MHz
950-2150
Frequency range TER
MHz
47-862
Gain - SAT [950-2150 MHz]
dB
- 6.0
Gain - TER [47-862 MHz]
dB
4.0
Isolation SAT to TER
dB
22
Isolation TER to SAT
dB
22
Isolation cross polarisation H/V
dB
25
Isolation out-out SAT
dB
30
Isolation out-out TER
dB
30
Return loss SAT inputs
dB
12
Return loss SAT outputs
dB
7
Return loss TER inputs
dB
11
Return loss TER outputs
dB
7
Output level SAT @ -35 dB IMD3 dBµV
100
Output level TER @ 60dB IMD3
dBµV
88
Impedance input/output
Ohm
75
Switching
V/DC
Supply voltage
V/DC
15.0 (± 1.0)
Power supply
Included
Max. current pass
mA
600
per F-connector
Connectors
F-female
Colourcoding of IF and
Yes
TER inputs
Temperature range
deg.
0...+55
Dimensions (H x D x W)
103 x 71x 249
TMS 5x6P
Stand alone
300326
TMS 5x8P
Stand alone
300328
TMS 5x12P
Stand alone
300322
TMS 5x16P
Stand alone
300327
4 SAT, 1 TER
4 SAT, 1 TER
4 SAT, 1 TER
4 SAT, 1 TER
4 SAT, 1 TER
4 SAT, 1 TER
6
8
12
950-2150
950-2150
950-2150
47-862
47-862
47-862
- 5.0
- 5.0
- 5.0
3.0
3.0
0.0
28
28
22
25
25
22
28
28
25
35
35
35
28
28
28
12
12
11
7
7
8
11
11
11
7
7
8
100
100
100
85
85
85
75
75
75
13V/18V - 13V/22kHz - 18V/22kHz
15.0 (± 1.0)
15.0 (± 1.0)
15.0 (± 1.0)
Included
Included
Included
600
600
600
4 SAT, 1 TER
4 SAT, 1 TER
16
950-2150
47-862
- 3.0
4.0
22
22
25
35
28
10
8
10
8
100
85
75
15.0 (± 1.0)
Included
600
F-female
Yes
F-female
Yes
F-female
Yes
F-female
Yes
0...+55
103 x 71x 359
0...+55
103 x 71x 359
0...+55
103 x 71x 459
0...+55
103 x 71x 559
TRIAX | 204
Multi
switches
Technical data
Multiswitches
| TMP 9x Single w/PSU
Triax TMP 9x is an is an excellent solution
to the dilemma in many stand-alone multi
switch installations: The more subscribers
you want to supply from one multi switch,
the longer and different the cables will be.
Using traditional multi switches this will
present subscribers with very different
signal levels, and can cause all kind of
problems.
With adjustable attenuator per polarity
(0-15 dB). Slide switch for long, medium
and short subscriber cable runs (0, 6 and
12 dB). 8 satellite polarities and 1 terrestrial input, combined output. Integrated
switch mode power supply. Versions for
4 to 32 subscriber outputs per unit.
Technical data
Type:
Multi
switches
Art. No: (EU plug)
Art. No: (UK plug)
TMP 9X8
Stand alone
301630
305380
Number of inputs
Insertion loss - trunkline TER
dB
Insertion loss - trunkline SAT
dB
Subscriber outputs
pcs.
Frequency range SAT
MHz
Frequency range TER
MHz
Slope control TER
dB
Input polarity gain control SAT
dB
Input polarity gain control TER
dB
Isolation SAT to TER
dB
Isolation TER to SAT
dB
Isolation cross polarisation H/V
dB
Isolation out-out SAT
dB
Isolation out-out TER
dB
Return loss SAT inputs
dB
Return loss SAT outputs
dB
Return loss TER inputs
dB
Return loss TER outputs
dB
Output level SAT @ -35 dB IMD3
dBµV
Output level TER @ 60dB IMD3
dBµV
Output level control - long cable
dB
Output level control - med. cable
dB
Output level control - short cable
dB
LNB current max.
mA
Line power voltage (TER)
V
Line power current (TER)
mA
Switch commands
Supply voltage
V/DC
Power supply
VAC
Power supply current
A
Connectors
Colourcoding of IF and TER inputs
Temperature range
deg.
Dimensions (H x D x W)
8 SAT, 1 TER
8 SAT, 1 TER
8 SAT, 1 TER
3.0
3.0
3.0
3.0
3.0
3.0
8
12
16
950-2150
950-2150
950-2150
47-862
47-862
47-862
10.0
10.0
10.0
4 x 10.0
4 x 10.0
4 x 10.0
15.0
15.0
15.0
32
32
32
32
32
32
30
30
30
30
30
30
30
30
30
10
10
10
8
8
8
10
10
10
8
8
8
100
100
100
95
95
95
600
600
600
12.0
12.0
12.0
50
50
50
13V/18V - 13V /22 kHz - 18V /22 kHz - DiSEqC 2.0
18.0
18.0
18.0
180-264
180-264
180-264
1.5 (47-63 HZ)
1.5 (47-63 HZ)
1.5 (47-63 HZ)
F-female
F-female
F-female
Yes
Yes
Yes
0...+55
0...+55
0...+55
157 x 51 x 190
157 x 51 x 240
157 x 51 x 240
205 | TRIAX
TMP 9X12
Stand alone
301632
305382
TMP 9X16
Stand alone
301634
305384
Multiswitches
| TMP 9x Single w/PSU
Triax TMP 9x is an is an excellent solution
to the dilemma in many stand-alone multi
switch installations: The more subscribers
you want to supply from one multi switch,
the longer and different the cables will be.
Using traditional multi switches this will
present subscribers with very different
signal levels, and can cause all kind of
problems.
With adjustable attenuator per polarity
(0-15 dB). Slide switch for long, medium
and short subscriber cable runs (0, 6 and
12 dB). 8 satellite polarities and 1 terrestrial input, combined output. Integrated
switch mode power supply. Versions for
4 to 32 subscriber outputs per unit.
Type:
Art. No: (EU plug)
Art. No: (UK plug)
TMP 9X24
Stand alone
301636
305386
TMP 9X32
Stand alone
301638
305388
Number of inputs
8 SAT, 1 TER
8 SAT, 1 TER
Insertion loss - trunkline TER
dB
Insertion loss - trunkline SAT
dB
Subscriber outputs
pcs.
Frequency range SAT
MHz
Frequency range TER
MHz
Slope control TER
dB
Input polarity gain control SAT
dB
Input polarity gain control TER
dB
Isolation SAT to TER
dB
Isolation TER to SAT
dB
Isolation cross polarisation H/V
dB
Isolation out-out SAT
dB
Isolation out-out TER
dB
Return loss SAT inputs
dB
Return loss SAT outputs
dB
Return loss TER inputs
dB
Return loss TER outputs
dB
Output level SAT @ -35 dB IMD3 dBµV
Output level TER @ 60dB IMD3
dBµV
Output level control - long cable
dB
Output level control - med. cable
dB
Output level control - short cable
dB
LNB current max.
mA
Line power voltage (TER)
V
Line power current (TER)
mA
Switch commands
Supply voltage
V/DC
Power supply
VAC
Power supply current
A
Connectors
Colourcoding of IF and TER inputs
Temperature range
deg.
Dimensions (H x D x W)
Multi
switches
Technical data
0.0
0.0
2.0
2.0
24
32
950-2150
950-2150
47-862
47-862
10.0
10.0
4 X 15.0
4 X 15.0
15.0
15.0
32
32
32
32
30
30
30
30
30
30
10
10
10
10
12
12
10
10
100
100
95
95
0.0
0.0
6.0
6.0
12.0
12.0
600
600
12.0
12.0
50
50
13V/18V - 13V /22 kHz - 18V /22 kHz - DiSEqC 2.0
18.0
18.0
180-264
180-264
1.5 (47-63 HZ)
1.5 (47-63 HZ)
F-female
F-female
Yes
Yes
0...+55
0...+55
157 x 51 x 340
157 x 51 x 340
TRIAX | 206
Multiswitches
| TMP 5x Single w/PSU
Triax TMP 5x is an is an excellent solution
to the dilemma in many stand-alone multi
switch installations: The more subscribers
you want to supply from one multi switch,
the longer and different the cables will be.
Using traditional multi switches this will
present subscribers with very different
signal levels, and can cause all kind of
problems.
With adjustable attenuator per polarity
(0-15 dB). Slide switch for long, medium
and short subscriber cable runs (0, 6 and
12 dB). 4 satellite polarities and 1 terrestrial
input, combined output. Integrated switch
mode power supply. Versions for 4 to 32
subscriber outputs per unit.
Technical data
Type:
Art. No: (EU plug)
Art. No: (UK plug)
Multi
switches
Number of inputs
Insertion loss - trunkline TER
dB
Insertion loss - trunkline SAT
dB
Subscriber outputs
pcs.
Frequency range SAT
MHz
Frequency range TER
MHz
Slope control TER
dB
Input polarity gain control SAT
dB
Input polarity gain control TER
dB
Isolation SAT to TER
dB
Isolation TER to SAT
dB
Isolation cross polarisation H/V
dB
Isolation out-out SAT
dB
Isolation out-out TER
dB
Return loss SAT inputs
dB
Return loss SAT outputs
dB
Return loss TER inputs
dB
Return loss TER outputs
dB
Output level SAT @ -35 dB IMD3 dBµV
Output level TER @ 60dB IMD3
dBµV
Output level control - long cable
dB
Output level control - med. cable
dB
Output level control - short cable
dB
LNB current max.
mA
Line power voltage (TER)
V
Line power current (TER)
mA
Switch commands
Supply voltage
V/DC
Power supply
VAC
Power supply current
A
Connectors
Colourcoding of IF and
TER inputs
Temperature range
deg.
Dimensions (H x D x W)
207 | TRIAX
TMP 5X6 Stand alone
TMP 5X8 Stand alone
301643
301620
305370
4 SAT, 1 TER
3.0
3.0
6
950-2150
47-862
10.0
4 X 10.0
15.0
32
32
30
30
30
10
8
10
8
100
95
600
12.0
50.0
TMP 5X12 Stand
alone
301622
305372
4 SAT, 1 TER
3.0
3.0
8
950-2150
47-862
10.0
4 X 10.0
15.0
32
32
30
30
30
10
8
10
8
100
95
600
12.0
50.0
13V/18V - 13V/22 kHz - 18V/22 kHz
18.0
18.0
180-264
180-264
1.5 (47-63 HZ)
1.5 (47-63 HZ)
F-female
F-female
Ja
Yes
4 SAT, 1 TER
3.0
3.0
12
950-2150
47-862
10.0
4 X 10.0
15.0
32
32
30
30
30
10
8
10
8
100
95
600
12.0
50.0
0...+55
157 x 51 x 190
0...+55
157 x 51 x 240
0...+55
157 x 51 x 190
18.0
180-264
1.5 (47-63 HZ)
F-female
Yes
Multiswitches
| TMP 5x Single w/PSU
Triax TMP 5x is an is an excellent solution
to the dilemma in many stand-alone multi
switch installations: The more subscribers
you want to supply from one multi switch,
the longer and different the cables will be.
Using traditional multi switches this will
present subscribers with very different
signal levels, and can cause all kind of
problems.
With adjustable attenuator per polarity
(0-15 dB). Slide switch for long, medium
and short subscriber cable runs (0, 6 and
12 dB). 4 satellite polarities and 1 terrestrial
input, combined output. Integrated switch
mode power supply. Versions for 4 to 32
subscriber outputs per unit.
Technical data
TMP 5x16
Stand alone
301624
305374
Art. No: (EU plug)
Art. No: (UK plug)
Number of inputs
Insertion loss - trunkline TER
Insertion loss - trunkline SAT
Subscriber outputs
Frequency range SAT
Frequency range TER
Slope control TER
Input polarity gain control SAT
Input polarity gain control TER
Isolation SAT to TER
Isolation TER to SAT
Isolation cross polarisation H/V
Isolation out-out SAT
Isolation out-out TER
Return loss SAT inputs
Return loss SAT outputs
Return loss TER inputs
Return loss TER outputs
Output level SAT @ -35 dB IMD3
Output level TER @ 60dB IMD3
Output level control - long cable
Output level control - med. cable
Output level control - short cable
LNB current max.
Line power voltage (TER)
Line power current (TER)
Switch commands
Supply voltage
Power supply
Power supply current
Connectors
Colourcoding of IF and
TER inputs
Temperature range
Dimensions (H x D x W)
dB
dB
MHz
MHz
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dBµV
dBµV
dB
dB
dB
mA
V
mA
V/DC
VAC
A
deg.
TMP 5X24
Stand alone
301626
305376
4 SAT, 1 TER
0.0
3.0
16
950-2150
47-862
10.0
4 x 10.0
15.0
32
32
30
30
30
10
8
10
8
100
95
600
12.0
50.0
TMP 5X32
Stand alone
301628
305378
4 SAT, 1 TER
0.0
2.0
24
950-2150
47-862
10.0
4 X 10.0
15.0
32
32
30
30
30
10
8
10
8
100
95
0
6
12
600
12.0
50.0
13V/18V - 13V/22 kHz - 18V/22 kHz
18.0
18.0
180-264
180-264
1.5 (47-63 HZ)
1.5 (47-63 HZ)
F-female
F-female
Yes
Yes
18.0
180-264
1.5 (47-63 HZ)
F-female
Yes
0...+55
157 x 51 x 240
0...+55
157 x 51 x 340
0...+55
157 x 51 x 340
4 SAT, 1 TER
0.0
3.0
32
950-2150
47-862
10.0
4 x 10.0
15.0
32
32
30
30
30
10
8
10
8
100
95
0
6
12
600
12.0
50.0
TRIAX | 208
Multi
switches
Type:
Multiswitches
| TMPR 5x Single, STB powered
Triax TMPR 5x multiswitches
These STB remote powered, stand alone
multiswitches are designed to be installed where no landlord supply exists.
Technical data
Type:
Art. No:
Multi
switches
Number of inputs
Insertion loss - TER
Insertion loss - SAT
Subscriber outputs
Frequency range SAT
Frequency range TER
Slope control TER
Input polarity gain control SAT
Input polarity gain control TER
Isolation SAT to TER
Isolation TER to SAT
Isolation cross polarisation H/V
Isolation out-out SAT
Isolation out-out TER
Return loss SAT inputs
Return loss SAT outputs
Return loss TER inputs
Return loss TER outputs
Output level SAT @ -35 dB IMD3
Output level TER @ 60dB IMD3
Impedance input/output
Switching
Power supply
Max. current pass
per F-connector
Connectors
Colourcoding of IF and
TER inputs
Temperature range
Dimensions (H x D x W)
209 | TRIAX
pcs.
dB
dB
pcs.
MHz
MHz
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dBµV
dBµV
Ohm
V/DC
mA
deg.
TMPR 5X8
Remote powered
305297
TMPR 5X12
Remote powered
305298
TMPR 5X16
Remote powered
305299
4 SAT, 1 TER
0.0
2.0
8
950-2150
47-862
10.0
10.0
15.0
30
30
30
30
30
10.0
8.0
10.0
8.0
101
85
75
4 SAT, 1 TER
0.0
2.0
16
950-2150
47-862
10.0
10.0
15.0
30
30
30
30
30
10.0
8.0
10.0
8.0
101
85
75
600
4 SAT, 1 TER
0.0
2.0
12
950-2150
47-862
10.0
10.0
15.0
30
30
30
30
30
10.0
8.0
10.0
8.0
101
85
75
13V/18V - 13V/22kHz - 18V/22kHz
Remote power from set-top box
600
F-female
Yes
F-female
Yes
F-female
Yes
0...+55
147 x 56 x 170
0...+55
197 x 56 x 170
0...+55
197 x 56 x 170
600
Multiswitches
| Trunk TAPs and splitters
Taps and Splitters
Expand the TMS 5x series into a
cascadable system. Using TMS 55 taps
makes it possible to construct large
cascadable systems. Different tapvalues allow fine-tuning of available
signal levels.
By using splitters you can balance your
distribution system the best possible way.
The MultiTAP product allows you to
extend any cascade into very large
systems using a passive TAP technique
in the trunk, and 3 active TAPs on each
level.
Type:
Art. No:
Number of inputs
Number of outputs
Number of taps
Frequency range SAT
Frequency range TER
Tap loss SAT
Tap loss TER
Through loss SAT
Through loss TER
Isolation trunkline
pcs.
pcs.
pcs.
MHz
MHz
dB
dB
dB
dB
dB
Connectors
Colourcoding of IF and
TER inputs
Temperature range
Dimensions (H x D x W)
degrees
TMS 55-12
TAP
300313
TMS 55-15
TAP
300333
TMS 55-20
TAP
300343
TMS 55-24
TAP
300353
4 SAT, 1 TER
4 SAT, 1 TER
4 SAT, 1 TER
950-2150
47-862
12.5
12.5
1.2 ±1.0
1.5 ±1.5
4 SAT, 1 TER
4 SAT, 1 TER
4 SAT, 1 TER
950-2150
47-862
15.0
15.0
1.2 ±1.0
1.5 ±1.5
4 SAT, 1 TER
4 SAT, 1 TER
4 SAT, 1 TER
950-2150
47-862
20.0
20.0
1.2 ±1.0
1.5 ±1.5
4 SAT, 1 TER
4 SAT, 1 TER
4 SAT, 1 TER
950-2150
47-862
24.0
24.0
1.2 ±1.0
1.5 ±1.5
> 30.0
> 30.0
> 30.0
> 30.0
F-female
F-female
F-female
F-female
Yes
Yes
Yes
Yes
0...+55
145 x 42 x 119
0...+55
145 x 42 x 119
0...+55
145 x 42 x 119
0...+55
145 x 42 x 119
TRIAX | 210
Multi
switches
Technical data
Multiswitches
| Trunk TAPs and splitters
Taps and Splitters
Expand the TMS 5x series into a
cascadable system. Using TMS 55 taps
makes it possible to construct large
cascadable systems. Different tapvalues allow fine-tuning of available
signal levels. By using splitters you can
balance your distribution system the
best possible way.
The MultiTAP product allows you to
extend any cascade into very large
systems using a passive TAP technique
in the trunk, and 3 active TAPs on each
level.
Technical data
Type:
Art. No:
Multi
switches
Number of inputs
Number of trunk inputs
Insertion loss - TER
F-con
dB
TMT 553
MultiTAP
307450
TMS 510
Splitter
300319
TMM 5x10
Splitter
305319
TMM 4x10
Splitter
305320
4 SAT, 1 TER
5
4 SAT, 1 TER
4 SAT, 1 TER
4 SAT, 1 TER
2x4 SAT, 2x1 TER
2x4 SAT, 2x1 TER
47-2150
47-2150
4.5
4.3
4.5
4.3
> 20.0
> 22.0
> 20.0
> 22.0
In 15.0/out 15.0
In 15.0/out 15.0
In 15.0/out 15.0
In 15.0/out 15.0
F-female
Yes
F-female
Yes
F-female
Yes
0...+55
0...+55
0...+55
<2
Insertion loss - SAT
dB
<2
Insertion loss - trunkline TER
dB
Typ. +1...-3
Insertion loss - trunkline SAT
dB
Typ. -4...0
Number of outputs
Number of trunk outputs
Number of taps
Frequency range
Frequency range SAT
Frequency range TER
Through loss SAT
Through loss TER
Adjustable attenuator SAT
Adjustable attenuator TER
Isolation trunkline
Isolation out-out SAT
Isolation out-out TER
Return loss SAT inputs
Return loss SAT outputs
Return loss TER inputs
Return loss TER outputs
Return loss switch out - SAT
Return loss switch out - TER
Impedance input/output
External power supply
Connectors
Colourcoding of IF and TER
inputs
Temperature range
F-con
4 SAT, 1 TER
5
3
8 SAT, 2 TER
MHz
MHz
950-2150
5-862
950-2150
47-862
4.0 ±1.0
6.0 ±1.0
Dimensions (H x D x W)
211 | TRIAX
dB
dB
0...15
0...15
> 30.0
dB
dB
dB
dB
dB
dB
dB
dB
Ohm
V/DC
10
10
10
10
10
10
75
18
F-female
195 x 183 x 50
145 x 42 x 255
Multiswitches
| Trunk Launch- and Line- Amplifiers
A launch amplifier is the first amplifier in a
multi switch installation, typically near the
LNB and dish installation. It is designed to
boost your signal to get more mileage in a
long cascaded installation.
Using a line amplifier you can compensate
for the cable losses further down the trunk
lines of your satellite distribution system.
REMEMBER:
Due to the laws of physics there are limits
to how many line amplifiers you can add
into a multi switch cascade before your
signal quality deterioates beyond practical
use. You may want to check out the
TMS 553 MultiTAP too.
Type:
Art. No:
TMS 2
IF-amplifier
300275
TMS 55
IF-amplifier
300315
TMS 55
IF-amplifier - UK
300360
TMS 8
IF-amplifier
300425
Number of inputs
pcs.
2 SAT
4 SAT, 1 TER
4 SAT, 1 TER
8 SAT
Number of outputs
Frequency range SAT
Frequency range TER
Gain - SAT [950-2150 MHz]
Gain - TER [47-862 MHz]
Adjustable attenuator SAT
Adjustable attenuator TER
Equalization SAT
Equalization TER
Noise figure SAT
Isolation SAT to SAT
Return loss SAT
Output level SAT @ -35 dB IMD3
Output level TER - 47-862 MHz
Impedance input/output
Supply voltage
pcs.
MHz
2 SAT
950-2150
4 SAT, 1 TER
950-2150
47-862
20-25 (± 2)
17 (± 2)
0-15
0-17
5 (fixed)
7-12 (adjustable)
< 12.0
4 SAT, 1 TER
950-2150
47-862
20-25 (± 2)
17 (± 2)
0-15
0-17
5 (fixed)
7-12 (adjustable)
< 12.0
8 SAT
950-2200
dB
30.0
dB
0-10
dB
0-8
dB
< 12.0
dB
dBµV
10.0
115
Ohm
V/DC
75
18
(via DC plug)
External power
adaptor
F-female
F-female
2 x red
Power supply
Connectors
DC input connector
Control LEDs
Colourcoding of IF
and TER inputs
Temperature range
Dimensions (H x D x W)
degrees
0...+50
10.0
10.0
110
110
105
105
75
75
18 (
18
via DC plug or trunk) (via DC plug or trunk)
External power
External power
adaptor
adaptor
F-female
F-female
Phone
Phone
32-36 (4dB slope)
17 (± 2)
0-20
0-10
< 16.0
> 25
10.0
120
75
15
Internal power
supply
F-female
Yes
Yes
Yes
0...+50
105 x 43 x 196
0...+50
105 x 43 x 196
0...+50
140 x 121 x 250
TRIAX | 212
Multi
switches
Technical data
Multiswitches
| Trunk Launch- and Line- Amplifiers
A launch amplifier is the first amplifier in a
multi switch installation, typically near the
LNB and dish installation. It is designed to
boost your signal to get more mileage in a
long cascaded installation.
Using a line amplifier you can compensate
for the cable losses further down the trunk
lines of your satellite distribution system.
REMEMBER:
Due to the laws of physics there are limits
to how many line amplifiers you can add
into a multi switch cascade before your
signal quality deterioates beyond practical
use. You may want to check out the
TMS 553 MultiTAP too.
Technical data
Type:
Art. No:
TMS 9
IF-amplifier
300365
TMS 13
IF-amplifier
307415
TMS 17
IF-amplifier
301501
Multi
switches
Number of inputs
Number of outputs
pcs.
pcs.
8 SAT, 1 TER
12 SAT, 1 TER
16 SAT, 1 TER + power link
8 SAT, 1 TER
12 SAT, 1 TER
16 SAT, 1 TER + power link
Frequency range SAT
Frequency range TER
MHz
MHz
950-2150
47-862
950-2150
5-862
Return path TER
Gain - SAT [950-2150 MHz]
Gain - TER [47-862 MHz]
Attenuation SAT
Attenuation TER
Adjustable attenuator SAT
Adjustable attenuator TER
Equalization SAT
Equalization TER
Noise figure SAT
Noise figure TER
Isolation SAT to SAT
Isolation TER to SAT
Isolation cross polarisation H/V
Isolation out-out SAT
Return loss
Return loss SAT
Output level SAT @ -35 dB IMD3
Output level TER @ 60dB IMD3
Output level TER - 47-862 MHz
Impedance input/output
Switching voltage
Supply voltage
Power supply
Power supply current
Connectors
Colourcoding of IF
and TER inputs
Temperature range
Dimensions (H x D x W)
MHz
dB
dB
14 (± 2)
17 (± 2)
950-2150 (active)
5-862 (85 to 862 MHz
with active return path)
5 to 65 (switchable on/off)
18.0...24.0 (± 2.0)
17.0 (± 2.0)
0 - 10.0
0 - 10.0
213 | TRIAX
dB
dB
dB
dB
0-20
0-20
5.0 (fixed)
2-15.0 (adjustable)
0 - 6,0 (switchable)
0 - 15.0
< 8.0
< 5.0
5-65 (passive)
18-24 (± 2)
17
0-10
0-10
0 or 6.0 (switchable)
0-15.0 (adjustable)
< 8.0
< 7.0
30.0
22.0
> 28.0
> 30.0
> 10.0 (all ports)
dB
dBµV
10.0
110
dBµV
Ohm
105
75
V/DC
18
External power adaptor
degrees
110
105
F-female
Yes
75
Ver. 13.0/Hor. 17.5 (± 1.0)
18.0 (± 0.5)
External
1600
F-female
Yes
0...+50
152 x 51 x 253
0...+55
163 x 53 x 334
10.0
110
105
75
18 (via power link)
External power adaptor
F-female
Yes
0...+55
152 x 51 x 355
Multiswitches
| Trunk Launch- and Line- Amplifiers
A launch amplifier is the first amplifier in a
multi switch installation, typically near the
LNB and dish installation. It is designed to
boost your signal to get more mileage in a
long cascaded installation.
Using a line amplifier you can compensate
for the cable losses further down the trunk
lines of your satellite distribution system.
REMEMBER:
Due to the laws of physics there are limits
to how many line amplifiers you can add
into a multi switch cascade before your
signal quality deterioates beyond practical
use. You may want to check out the
TMS 553 MultiTAP too.
Technical data
Art. No:
SAT Line
amplifier
300401
Input - TER [47-860 MHz]
pcs.
Input - BI/FM [47-108 MHz]
pcs.
Input - BIII/DAB [170-230 MHz] pcs.
Input - UHF 1 [470-860 MHz]
pcs.
Input - UHF 2 [470-860 MHz]
pcs.
Input - SAT [950-2150 MHz]
pcs.
1
Number of outputs
1 SAT
Frequency range
MHz
47-2300
Frequency range TER
Frequency range SAT
Gain - TER [47-862 MHz]
dB
Gain - SAT [950-2150 MHz]
dB
16-20
Slope control TER
dB
Slope control UHF 2
dB
Slope control SAT
dB
Polarity gain control TER
dB
Polarity gain control SAT
dB
Isolation trunk to trunk
dB
Return loss TER
dB
Return loss SAT
dB
10.0
Output level TER @ 60dB IMD3
dBµV
Output level SAT @ -35 dB IMD3 dBµV
100
LNB power supply max.
LNB current max.
Impedance input/output
Ohm
75
Supply voltage
V
Power consumption
mA
Line powering via in- or output
External power supply
V/DC 15V (via trunk)
Max. current to mast amplifier
Connectors
F-female
DC switch (for injecting DC)
Through voltage TER
Temperature range
TMM 44
IF-launch
amplifier
305300
TMM TDA
Terr. dist.
amplifier
305306
TMM TER
Launch
amplifier
305315
1
TMM 55
IF-launch
amplifier
305335
1
1
1
1
1
4
4 SAT
1 TERR.
1 TERR.
47-862
47-862
30.0
40.0
950-2150
40.0
0-18
0-10
0-5
0-20
0-10
0-10
0-20
10.0
10.0
118.0
10.0
10.0
118.0
75
75
12/50
200
0-20
35
10.0
115
2x14 / 2x18
400
75
4
4 SAT, 1 TERR.
47-862
950-2150
17.0
25.0
2-15
0-5
20
20
32
10.0
10.0
105
110.0
2x14 / 2x18
400
75
390
200
350
18/13 (± 0.5)
18/13 (± 0.5)
18 (via 3.5 jack) 18 (via 3.5 jack) 18 (via 3.5 jack) 18 (via 3.5 jack)
12 (± 0.5)
F-female
F-female
F-female
F-female
Switchable
Switchable
12 (± 0.5)
0...+55
Switchable
12 (± 0.5)
0...+55
Switchable
12 (± 0.5)
0...+55
0...+55
TRIAX | 214
Multi
switches
Type:
Multiswitches
| Trunk Launch- and Line- Amplifiers
A launch amplifier is the first amplifier in a
multi switch installation, typically near the
LNB and dish installation. It is designed to
boost your signal to get more mileage in a
long cascaded installation.
Using a line amplifier you can compensate
for the cable losses further down the trunk
lines of your satellite distribution system.
REMEMBER:
Due to the laws of physics there are limits
to how many line amplifiers you can add
into a multi switch cascade before your
signal quality deterioates beyond practical
use. You may want to check out the
TMS 553 MultiTAP too.
Technical data
Type:
Art. No:
Multi
switches
Number of inputs
Distribution outputs (SAT + Ter)
Test outputs (SAT + Ter) - 30 dB
Connectors
Frequency range SAT
Frequency range TER
Return path TER (switchable)
Gain SAT
Gain TER
Gain return path
F-con
MHz
MHz
MHz
dB
dB
dB
Noise figure SAT
dB
Noise figure TER
dB
Adjustable attenuator SAT
Slope adjustment SAT
Equalizer
SAT
Isolation cross polarisation H/V
Isolation out - out SAT
Isolation out - out TER
Return loss SAT inputs
Return loss SAT outputs
Return loss TER inputs
Return loss TER outputs
Output level SAT (IMD3 - 35 dB)
Output level TER (IMD3 - 60 dB)
Power supply
Switching commands
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dBµV
dBµV
VDC
VDC/A
TLA 340E
Line IF-amplifier
300384
300386
2 SAT, 1 TER
2
2
female
950-2150
47-862
5-30
40.0
- 8.0
- 8.0
2 SAT
2
2
female
950-2150
47-862
5-30
40.0
38.0
- 3.0
10.0
8.0
0-20 (on each sat input)
180-240
13 VDC/1
18 VDC/2
0-20 (on each sat input)
0...15
0-20 (on each sat input)
> 45
> 50
> 25
10
8
8
8
120
116
180-240
13 VDC/1
18 VDC/2
6.0
0-20 (on each sat input)
> 45
> 45
10
8
10
8
120
0/22 - 0/13/18
0/22 - 0/13/18
300 max.
300 max.
Temperature range
mA
oC
0...+55
0...+55
Dimensions (H x D x W)
mm
182 x 45 x 150
182 x 45 x 150
Power consumption per SAT-IF
215 | TRIAX
kHz/VDC
THA 340E
Launch IF-amplifier
Multiswitches
| Power supplies
Power supply for your multi switch
installation comes in many different
falvours in terms of voltage,current
supply and connector. Observe that the
DC output connector may be different
in different switch series. Make sure you
get the one that fits the multi switch you
are installing.
Type:
Art. No: (EU plug)
Art. No: (UK plug)
Number of inputs
Insertion loss - TER
Insertion loss - SAT
Number of outputs
Frequency range
Frequency range SAT
Isolation out-out SAT
Isolation out-out TER
Return loss SAT outputs
Return loss TER outputs
Output voltage
LNB power supply max.
Impedance input/output
Supply voltage
Power supply current
Cable lenght from supply
Max. current
Input voltage
Inputs (230V)
Connectors
Through voltage TER
Colourcoding of IF and
TER inputs
Temperature range
Dimensions (H x D x W)
Remarks
TMS PSU
Power
supply
TMS 17
Power
supply
TMS 1820
SM Power
supply
TMM PSU
Power
supply
TMM PSI
Power
inserter
336195
301504
307410
307411
305340
305310
305311
4 SAT, 1 TERR.
dB
dB
pcs.
MHz
MHz
dB
dB
dB
dB
V/DC
Ohm
V
watt
mm
A
VAC
pcs.
1
47-63
1
47-63
1
1
47-63
15 (± 0.5)
15 (± 0.5)
18 (± 0.5)
18 (± 0.5)
75
75
75
75
12
1800
1800
1800
1800
1 x 0.6
1 x 2.0
1 x 2.0
1 x 1.9
96 - 250
1
RCA/phone plug
96 - 250
1
F-female
100-240
1
F-female
96 - 250
1
3,5mm DC plug
Yes
Yes
0...+50
64 x 111 x 35
0...+50
64 x 111 x 35
Incl. power cable,
mounting bracket
and power cable
with F-male
connector
V
deg.
Yes
0...+50
4 SAT, 1 TERR.
1.5
2.5
4 SAT, 1 TERR.
47-63
47-2150
35
35
11.0
11.0
3 x 14 / 2 x 18
13V - 18V /500
75
18 (3.5 jack)
F-female
12.0 ± 0.5V /1.5
Yes
0...+50
0...+50
64 x 111 x 35
Incl. power cable, Power supply
mounting bracket unit integrated
and power cable
with 3.5 mm mini
jack
TRIAX | 216
Multi
switches
Technical data
Multiswitches
| TMM-TMS accessories
TMM-TMS accessories for
multiswittches
Everything you need to make a
professional installation.
Technical data
Type:
Art. No:
Multi
switches
Connectors
Remarks
Type:
Art. No:
Connectors
Remarks
217 | TRIAX
pcs.
TMM LK
Connection lead
305309
TMM 75 ohm
terminator
305349
F-male to F-male
5 pack
F-female
TMS 5
Terminator Block
307452
TMM F_F male
quick connector
370009
TMM earth bond bar
4 in
305344
5 x female to male
F-male to F-male
4 + ground
female to male
Push-on terminator block
TMM RPL
Power lead
305350
1
Push-on earth bond bar
Multiswitches
| TMM-TMS accessories
TMM-TMS accessories for
multiswittches
Everything you need to make a
professional installation.
Technical data
TMM 2B - 2x1 DiSEqC TMM 3B - 3x1 DiSEqC TMM 4B - 4x1 DiSEqC
bridge switch
bridge switch
bridge switch
305352
305353
305354
Art. No:
Number of Input
Number of outputs
Return loss
Connectors
Temperature range
Dimensions (H x D x W)
Remarks
pcs.
pcs.
dB
°C
2
1
> 10.0
F-con (male/female)
-30 ... +60
66 x 22 x 80
DiSEqC switch
3
1
> 10.0
F-con (male/female)
-30 ... +60
66 x 22 x 113
DiSEqC switch
4
1
> 10.0
F-con (male/female)
-30 ... +60
66 x 22 x 149
DiSEqC switch
TRIAX | 218
Multi
switches
Type:
Notes
| for your personal notes
Multi
switches
219 | TRIAX