FDA WARNINGS:
Electric Dental Handpieces and Patient Burns
I
n 2007, the FDA came out with its initial report alerting
dental professionals that serious patient burns can occur
when electric dental handpieces overheat during dental
procedures.* As the FDA report states:
Broken Handpiece
Slowing You Down?
Get fast service from Hayes
Air & electric specialists!
1 Bad Apple Can Spoil
the Whole Bunch!
“ Burns may not be apparent to the
operator or the patient until after
the tissue damage has occurred, because the
anesthetized patient cannot feel the tissue burning
and the handpiece housing insulates the operator
from the heated attachment. These burns range
from first-degree burns to third-degree burns
requiring reconstructive surgery.”
NEW!
Metal Cutting Burs
Did You Know…
· One rusty instrument can ruin your other instruments and damage
your sterilizer
· Your instruments can become corroded if you don’t separate
different types of metals when cleaning or sterilizing
Protect your patients, your staff and your instrument investment! We’ve
helped you maintain your handpieces….now let us help you with your
instruments! See inside for training details!
MAVERICK TERMINATOR
We also sell Premium Carbide Burs
Starting at just $109
Call your local Hayes office to order!
In this first safety alert, the FDA reminded electric handpiece
users of the importance of properly maintaining the handpieces.
Since the notice, the FDA has received numerous additional
reports of patients being burned by electric dental handpieces
and has issued subsequent alerts and recommendations.
FDA Recommendations
The FDA is recommending that dental professionals do the
following to prevent patient burns:
• Be vigilant about maintaining electric dental handpieces
and electric oral bone cutting handpieces according to the
manufacturer’s instructions.
• Verify with the manufacturer the appropriate routine service
interval for your dental practice, based on the actual use
of your electric dental handpiece or electric intraoral bone
cutting handpieces.
• Train personnel to properly clean and maintain the handpieces.
• Develop a method for tracking maintenance and routine
service for these handpieces.
• Examine the handpieces and attachments prior to use. Do
not use worn drills or burs.
• Do not use a poorly maintained handpiece.
• Report overheating to the manufacturer.
How Hayes Can Help
Hayes Handpiece can help your practice
avoid this burning issue in 2 ways:
1. FACTORY-LEVEL REPAIRS OF
ELECTRIC DENTAL HANDPIECES.
“Your office should make it a priority
JOE HAYES, CEO
HAYES HANDPIECE
to get only factory-level repairs for your
COMPANY
electric dental handpieces,” explains Joe
Hayes, CEO of Hayes Handpiece Company. “This technology
is too new to trust just anyone with the repairs.” Hayes can
also help you track your service and maintenance.
2. STAFF TRAINING ON HOW TO PROPERLY MAINTAIN
ELECTRIC HANDPIECES. This is a very important part of
the process to avoid patient burns. Proper cleaning and
sterilization procedures may vary depending on manufacturer
and may differ from air-driven handpieces. “As part of our
maintenance education we can train staff on how to examine
attachments, drills and burs for wear and tear that could lead
to problems,” explains Hayes.
Call your local HAYES OFFICE regarding your electric
handpieces, or if you are considering purchasing electrics.
*See Public Health Notification: Patient Burns from Electric Dental Handpieces
www.hayeshandpiece.com
www.hayeshandpiece.com
LOCAL REPAIRS FROM THE HANDPIECE EXPERTS
HIGH-QUALITY REPAIRS • PROMPT TURNAROUND • FREE PICK-UP • LOCAL SERVICE • AUTOMATIC WARRANTY TRACKING
CERAMIC
BEARINGS
AVAILABLE
STAFF TRAINING
HIGH-SPEED OVERHAULS
ATTACHMENTS
ENDODONTIC HANDPIECES
6-MONTH TO 1-YEAR WARRANTY
MIDWEST • NSK • CHAMPION • LARES
STAR • KAVO • W&H/A-DEC • IMPACT AIR
6-MONTH WARRANTY
MIDWEST (straight and contra angle
attachment) • STAR (straight attachment
and motor-to-angle adapter) • KAVO
MANUFACTURER WARRANTY
W&H • TULSA DENTAL • MICROMEGA
ANTHOGYR • NOUVAG
Comprehensive In-Office CE Courses for Dental Professionals
Handpiece &
Sterilizer Maintenance
Improper maintenance is the #1 reason for
premature handpiece failure. Protect your
investment, and get the maximum life out
of your handpieces and sterilizer.
3 Learn proper maintenance procedures
for high-speeds, low-speed motors,
swivels, scalers, surgical drills and
attachments
3 Understand different lubricants and
cleaners
3 Review flushing and autoclaving
procedures
3 Perfect for new staff or refresher
courses available
3 Learn how to get faster drying times
out of your sterilizer
$59 PER OFFICE (HA-HPMCE)—
Includes 1 CE Credit per attendee!
Instrument Processing
Taking care of your instruments makes
them safer and more effective so you can
protect your patients while operating at
maximum efficiency. In addition, we’ll
audit your instruments to determine what
needs to be sharpened or replaced.
3 Learn about the importance of presoaking instruments
3 Review cleaning, rinsing and drying
techniques
OSHA and CDC create a lot of anxiety for
dentists and dental office managers. We’ll
review what an OSHA consultant will focus
on, and the most common fines for dental
offices. We’ll cover how the CDC guidelines
have changed over the years, and the
simple steps you can take to protect your
patients and your staff.
3 How much could OSHA really cost
3 Improve the life of your sterilizer
3 Look at lubrication and sterilization
procedures
LOW-SPEED HEADS
REPLACEMENT TURBINES
6-MONTH TO 1-YEAR WARRANTY
OE TURBINES
MIDWEST • STAR • NSK/BRASSELER
BIEN-AIR • LARES • MORITA
AFTERMARKET TURBINES
MIDWEST • STAR • KAVO • N
SK/BRASSELER
BIEN-AIR • W&H/A-DEC
3- TO 6-MONTH WARRANTY
KAVO • MIDWEST PUSH BUTTON (Head
Overhaul) • STAR BALL BEARING (Head
Overhaul) • NSK
SONIC SCALERS
6-MONTH WARRANTY
STAR
SURGICAL & IMPLANT REPAIRS
MANUFACTURER WARRANTY
ANTHOGYR • HALL • STRYKER • 3M
MICROAIRE • NOUVAG • IMPACT AIR 45
NSK • SABRA OMS-45 • W&H
NOBEL BIOCARE • BIOMED • 3I
you?
MAINT.
TRAINING
AVAILABLE
3 Understand the latest CDC guidelines
or replacement
3 Determine optimal instrument quantity
based on patient load
(HA-IPCE)—
Includes 1 CE Credit per attendee!
3 Should you hire an OSHA consultant?
3 Learn what the Centers for Disease
Control (CDC) has to say about your
handpieces and instruments
$59 PER OFFICE
(HA-OCPRCE)—
Includes 1 CE Credit per attendee!
LOW-SPEED OVERHAULS
6-MONTH TO 1-YEAR WARRANTY
MIDWEST • S
TAR • C
HAMPION • L
ARES
LYNX/MEDIDENTA • KAVO • W
&H/A-DEC
Allow 30 minutes per course. In-office training not available in all markets.
You may access our CE courses online at www.hayeshandpiece.com/cecredit.htm
Get OSHA Certified!
STEP #1—Train on OSHA with Hayes
STEP #2—Get discount OSHA certification
www.hayeshandpiece.com
ULTRASONIC SCALERS
6-MONTH WARRANTY
CAVITRON® • AUTOSCALER™
COLETÉNE/WHALEDENT • BIOSONIC • TPC
DELMARVA • VETROSON • TONY RISO
AUTOCLAVES
MANUFACTURER WARRANTY
ON PARTS AND LABOR
STATIM 2000, 5000 & 7000
FACTORY TRAINED
FACTORYLEVEL
REPAIRS
Call your local Hayes office to schedule your training!
BUR GUARD
& HOSE
REPAIR
for dental
3 Evaluate instruments for sharpening
$59 PER OFFICE
OSHA &
CDC Pain Relief
ELECTRIC REPAIRS
FIBER OPTIC REPLACEMENT
MANUFACTURER WARRANTY
NSK • STAR • BIEN-AIR • W&H
KAVO
6-MONTH WARRANTY
MIDWEST TRADITION QUIET AIR
STAR 430 • KAVO • NSK/KINETIC
www.hayeshandpiece.com
CALL YOUR LOCAL HAYES OFFICE
FOR ALL YOUR REPAIR NEEDS