information - Ritter Dental Australia
Transcription
information - Ritter Dental Australia
T IN LE TA AF DY RE LE AN CE IS H EN TH A ER E AS EF UID R G information Recommended Dental Equipment Maintenance Programme DAILY MAINTENANCE 1. Wipedown dental unit and surgery surfaces using diluted non alcoholic solution. Do not spray directly onto surface - spray onto soft cloth. Do not use excessive solution. 2. Clean vacuum lines using non foaming vacuum line solution formulated per product instructions. Clean or replace solids collectors in every dental Clean or replace amalgam trap daily. unit. Autoclave vacuum handpieces where possible. 3. Flush dental unit water lines at beginning and end of each day. 4. Turn off dental unit master switch at end of day. Spray handpiece lubricant into second largest terminal hole 5. Ensure handpieces are lubricated at back of handpiece. Ensure lubricant reaches prior to every autoclave cycle. the handpiece head. 6. Check distilled water level in autoclave. Refill where necessary. 7. Turn off compressor and vacuum at end of day. 8. Turn off O2 and N20 gas tanks Always utilise handpiece lube at end of day. adaptors where available. WEEKLY MAINTENANCE 1. Disinfect dental unit water lines as instructed by equipment manufacturer, then store water lines dry over weekend. 2. Change solution in ultrasonic cleaner and clean tank. 3. Clean solids collector at vacuum pump (wet system suction). 4. Check separator at dental unit (dry system suction). Clean or replace as necessary. 5. Check oil level in compressor (for lubricated models). Replenish as necessary. 6. Drain compressor tank (may be required daily). 7. Check oil level in dental chair (for hydraulic models). Disinfect water lines, then leave dry over weekend by fitting an empty bottle and flushing unit until water runs out. MONTHLY MAINTENANCE 1. Check filter for mains water (where fitted). 2. Clean Plaster trap. Recommended handpiece air pressures 3. Check air Instrument Recom. pressure pressure Turbines Dabi Atlante Maxi 400, 2.4 bar (35psi) MS - 350 & RS - 350 settings to KaVo 640 B 2.2 bar (32psi) handpieces. W & H 700 series 2.2 bar (32psi) 4. Check rubber NSK 2.2 bar (32psi) goods on Midwest Tradition 2.2 bar (32psi) Nitrous Oxide KaVo 650 B 2.8 bar (41psi) System. W & H 898 LE 2.8 bar (41psi) Replace split Air motors Most brands 3.1 bar (45psi) tubings. Ensure handpiece air pressures are set per handpiece 5. Check contents manufacturers instructions of emergency resuscitation kit. SEMI-ANNUAL MAINTENANCE 1. Change compressor air filters. 2. Lubricate joints on dental light and delivery systems. 3. Clean x ray developer tanks with a commercial cleanser. Tighten loose screws and lubricate joints MISCELLANEOUS MAINTENANCE 1. Save all equipment invoices for reference. 2. Keep maintenance log. 3. Mark down name of serviceman that did the work for you. 4. Save work orders in case of ‘call backs’. 5. Save all booklets, manuals, trouble shooting guides and circuit diagrams for equipment. 6. Sterilise / autoclave all handpieces and instruments before sending to repair company. Save all Manuals For more information please contact:Clean or replace solids collector at vacuum pump. TWICE MONTHLY MAINTENANCE 1. Change solution in x ray developer and clean tanks. 2. Empty and Clean handpiece exhaust oil collector on dental unit. Phone (02) 9153 6700 Fax (02) 9153 6677 email: [email protected] Unit 29, 55-59 Norman St, Peakhurst NSW 2210 www.gritterdental.com.au