Data sheet - hq

Transcription

Data sheet - hq
‫مؤسسة هيثم قاضي التجارية‬
Hospital and Health Care (healthcare) Facilities
Negative Pressure Isolation Rooms
Positive Pressure Isolation Rooms
All Biological Controls air purification systems and equipment are HEPA filtered and
comply with all CDC Guidelines and is FDA 510K certified, mandatory for air
purification systems and equipment for use in Hospitals, Health Care (healthcare),
and Medical facilities. CDC, OSHA and JCAHO mandate all of the specifications below
for use in negative pressure isolation rooms.
FDA 510K Certified MANDATORY for use in hospital and heath care facilities in creating a
Negative Pressure Isolation Room or a Positive Pressure Isolation Room.
FDA Gov site
Additional Applications
Positive Pressure Isolation Rooms:
Greater air pressure in the isolation room than in the adjacent corridor or anteroom.
To prevent transmission from the outside environment to profoundly
immunosuppressed persons patients (HIV infection).
Fungi Spores Examples:
Prevention of aspergillosis in bone-marrow transplant recipients. Anthrax, Eryptoccus,
Micropolyspora
0114875686 ‫ هاتف‬6896-13321 ‫ الرياض‬،‫ الصحافة‬،‫ طريق االمام سعود بن فيصل‬4614
4614 Al Imam Saud Ibn Faysal Rd, As Sahafah, Riyadh 13321 – 6896 Tel: +966 11 487 5686
[email protected]
www.hq.-electro.com
‫مؤسسة هيثم قاضي التجارية‬
Create a Negative Pressure Isolation Room
MICROCON® ExC7 with Germicidal UV
Features for a Negative Pressure Isolation
Room System
Create negative pressure isolation room rooms
Create positive pressure isolation room rooms
3 capacity fans 1/5, 1/4, 1/2 HP
HEPA filtered
Ceiling or shelf mounted
Filter replacement from room side
Built-in Minihelic pressure gauge
Self-contained or isolated fan
View of ExC7 from within negative
pressure isolation room or positive
pressure isolation room.
Choice of CFM capacities depending on the size
of the negative pressure isolation room and/or
positive pressure isolation room
Filtered exhaust can be to outside of the
isolation room, exhaust, ventilation, ceiling
plenums or return air system back into the
isolation room
One base model w/UV option
All equipment units interface with ACCUSTAT®
Isolation Room Monitor
The MICROCON® Exhaust product line is a series of HEPA
filtration systems designed to exhaust controlled amounts of room
air to create negative pressure isolation rooms. CDC, OSHA and
JCAHO mandate the use of negative pressure isolation rooms for
known or suspected TB Tuberculosis patients and today Avian
Bird Flu Influenza. Compliance is a matter of hours at a fraction
of the cost of engineering controls.
Negative Pressure Isolation Room
Requirements:
Being compliant and meeting "CDC Guidelines:
Negative Pressure Isolation Rooms in hospital and
healthcare facilities must create at least 12 air
changes per hour." Our ExC7 has the appropriate
discharge of air outdoors or monitored HEPA highefficiency filtration of room air before the air is
returned through the duct work or vented to the
outside. The ExC7 can also be installed into a
facility's duct work in order to create a permanent
Same Isolation Room view with
Pre-filtered and HEPA exposed
These 12 ACH Air Changes per Hour
needs to be accurately monitored
(CDC Guidelines)
0114875686 ‫ هاتف‬6896-13321 ‫ الرياض‬،‫ الصحافة‬،‫ طريق االمام سعود بن فيصل‬4614
4614 Al Imam Saud Ibn Faysal Rd, As Sahafah, Riyadh 13321 – 6896 Tel: +966 11 487 5686
[email protected]
www.hq.-electro.com
‫مؤسسة هيثم قاضي التجارية‬
negative pressure isolation room at a more
affordable price than a standard room conversion.
Negative Pressure Isolation Room
Definition:
The relative air pressure difference between two
areas in a health care facility. An isolation room at
negative pressure has a lower pressure than that of
adjacent areas, which keeps air from flowing out of
the isolation room and into adjacent rooms or areas.
Positive Pressure Isolation Room Definition:
Greater air pressure in the isolation room than in the
adjacent corridor or anteroom. To prevent
transmission from the outside environment to
profoundly immunosuppressed persons/patients.
Recirculation Ventilation in which all or most of the
air that is exhausted from an area is returned to the
same area or other areas of the facility.
Biological Controls' ACCUSTAT™ room
pressure monitor is designed specifically for
monitoring low negative or positive pressure
differentials. Accurate pressurization is a
vital step in creating a compliant, controlled
and safe environment. Ideally suited for
monitoring hospital isolation rooms or
pressure differentials in other critical
applications. A large lighted digital display
readout identifies instantaneous subfractional pressure changes when compared
to the adjoining areas. Pressure readings
are accurate to within .001” WG with audio
and visual alarms identifying unsatisfactory
conditions. The ACCUSTAT™ utilizes a highly
sensitive pressure transducer eliminating
the varying inconsistencies of “airflow”
monitors. Air pressure tends to be more
consistent and less corrupted by airflow
direction disruption, thereby reducing the
frequency of false alarms and inconsistent.
ExC7 for Negative Pressure Isolation Rooms
The ExC7 is a high capacity self-contained
HEPA filtered exhaust unit. When placed
in a 2x2 drop ceiling grid, it requires only
13" of ceiling clearance. Its fan is housed in
a separate enclosure while the ExC7 fan is
integrated into the filter housing. This unit
is highly recommended for creating
hospital negative pressure isolation rooms
for TB patients and Avian Bird Flu
Influenza H5N1 patients and assistance
with preparedness. Positive Isolation
Rooms for HIV infection.
ExC7 Isolation Room Equipment Blower Box and Diffuser
A swing-down stainless steel grille allows easy and safe in-room access to filters for maintenance and replacement. Individual
components are connected by 10" or 12" ducting which directs a high volume of filtered air to your choice of exhaust locations.
Filtered air can also be returned to the room through a ceiling- mounted diffuser to provide dilution and in-room air changes. A
built-in pressure gauge continually monitors the unit's performance.
0114875686 ‫ هاتف‬6896-13321 ‫ الرياض‬،‫ الصحافة‬،‫ طريق االمام سعود بن فيصل‬4614
4614 Al Imam Saud Ibn Faysal Rd, As Sahafah, Riyadh 13321 – 6896 Tel: +966 11 487 5686
[email protected]
www.hq.-electro.com
‫مؤسسة هيثم قاضي التجارية‬
Isolation Room Equipment
Built-In Pressure G
auge
ExC7-UV Isolation Room requiring UV
The ExC7-UV is identical to the ExC7, except for the addition of four
UV lamps. In applications requiring UV, this configuration improves
performance by the addition of HEPA filtration. Four high intensity
UV lamps are placed upstream of the filters, virtually eliminating
periodic bulb maintenance within the isolation room by preventing
particle buildup on the lamps surfaces, thereby cutting down their
irradiation effectiveness.
Lamps are shielded and a built-in digital hour meter and electronic
light sensor bar provide constant bulb performance status. A built-in
pressure differential gauge monitors filter performance to assure
operation at peak performance levels. This will help keep the isolation
room fully compliant.
ExC7-UV Isolation Room with view of
UV, HEPA & Pre-filter
0114875686 ‫ هاتف‬6896-13321 ‫ الرياض‬،‫ الصحافة‬،‫ طريق االمام سعود بن فيصل‬4614
4614 Al Imam Saud Ibn Faysal Rd, As Sahafah, Riyadh 13321 – 6896 Tel: +966 11 487 5686
[email protected]
www.hq.-electro.com
‫مؤسسة هيثم قاضي التجارية‬
ExC7-UV for in-room
irradiation and
filtration or creating
negative pressure
isolation rooms
housing TB and Avian
Bird Flu Influenza
H5N1 patients.
EXC7 Sample Configurations for Negative Pressure Rooms
Diagram Drawing Picture Photos of Negative Pressure Isolation Rooms - with Design
Variations
0114875686 ‫ هاتف‬6896-13321 ‫ الرياض‬،‫ الصحافة‬،‫ طريق االمام سعود بن فيصل‬4614
4614 Al Imam Saud Ibn Faysal Rd, As Sahafah, Riyadh 13321 – 6896 Tel: +966 11 487 5686
[email protected]
www.hq.-electro.com
‫مؤسسة هيثم قاضي التجارية‬
2 Models Available
Building
Management
System Specs
Part Number
Blower Type
Bearing Type
Volts
FLA Amps
HP/Speed
Elec. Protection
Free Air CFM
Delivered CFM
RPM
Service
MountPosition
Oper. Temp
FM Interface
Facility Elec
Interface
Fuse/Breaker
Hangers
Chassis
Duct Collars
Weight
Dimensions
Agency
Blower Module
1/4 HP
Blower Module
1/2 HP
EXC7 BM 1.25 (115V)
Or
EXC7 BM 2.25 (230V)
EXC7 BM 1.5 (115V)
Or
EXC7 BM 2.25 (230V)
PSC Direct Drive
Fwd Curve
Perm. Lub Ball
115V or 230v ,50/60Hz 1Ph
3.66A@115V,1.8@230v
1/4 HP, single speed
Auto-Reset
Thermal Overload
990 CFM
500 CFM
1080
Maintenance Free
ALL POSITIONS
-20º to 104º F
Cable & Chassis Connector Included
2X4” Elec Box Included
PSC Direct Drive
Fwd Curve
Perm. Lub Ball
115V or 230v ,50/60Hz 1Ph
3.66A@115V,1.8@230v
1/2 HP, single speed
Auto-Reset
Thermal Overload
1202 CFM
800 CFM
1390
Maintenance Free
ALL POSITIONS
-20º to 104º F
Cable & Chassis Connector Included
2X4” Elec Box
Included
10A Circuit Breaker
4 Eye-Hooks
20ga Galvz Steel, Powder Coat Paint
12”Diam x 2”high
2ea-In and Out
49 LBS
18”x17”x15”
(W x L x H)
FDA Approval
10A Circuit Breaker
4 Eye-Hooks
20ga Galvz Steel, Powder Coat Paint
12”Diam x 2”high
2ea-In and Out
36 LBS
18”x17”x15”
(W x L x H)
FDA Approval
0114875686 ‫ هاتف‬6896-13321 ‫ الرياض‬،‫ الصحافة‬،‫ طريق االمام سعود بن فيصل‬4614
4614 Al Imam Saud Ibn Faysal Rd, As Sahafah, Riyadh 13321 – 6896 Tel: +966 11 487 5686
[email protected]
www.hq.-electro.com