Technical Manual DH30(7)/33(7)50(7)/55(7)/60(7)
Transcription
Technical Manual DH30(7)/33(7)50(7)/55(7)/60(7)
Please read these instructions carefully as they will enable you to get maximum efficiency and reliability from your new Calorex Dehumidifier Technical Manual DH30(7)/33(7)50(7)/55(7)/60(7) WALL HUNG DEHUMIDIFIERS (D139460 ISSUE 21) 21/12/11 HEALTH AND SAFETY WARNING As the dehumidifier embodies electrical and rotational equipment, ONLY competent persons should carry out any work on this type of machine. (See Guarantee). Contents 1.0 INSTALLATION DETAILS ..................................................................................................................... 2 2.0 DATA SHEET ........................................................................................................................................ 5 3.0 WIRING DIAGRAMS ............................................................................................................................ 7 4.0 PERFORMANCE GRAPHS ................................................................................................................. 14 5.0 DIMENSIONS ..................................................................................................................................... 17 6.0 SPARE PARTS LISTS ........................................................................................................................ 25 7.0 OPTIONAL KITS ................................................................................................................................ 70 7.1 LPHW ASSEMBLIES ......................................................................................................................... 70 7.2 12V REMOTE HUMIDISTAT KIT ......................................................................................................... 71 7.3 12V REMOTE HUMIDISTAT CONNECTIONS ..................................................................................... 72 7.4 WEIR KIT ........................................................................................................................................... 73 7.5 AIR FILTER KITS ............................................................................................................................... 74 7.6 FLOOR STAND KITS ......................................................................................................................... 76 7.7 REMOVAL AND SERVICING OF DRIPTRAY ...................................................................................... 77 8.0 WARRANTY CONDITIONS ................................................................................................................. 78 page1 SD139460 ISSUE 21 1.0 INSTALLATION DETAILS LATEST EDITION REGULATIONS AND CALOREX UNITS 1,25 - 2,0M MUST BE FITTED WITH AN RCD AND BE AT LEAST 300mm FROM FLOOR CAN BE WITHIN 1,25M BUT MUST THEN BE 2,5M ABOVE POOL SURFACE 2,0-3,5M MUST BE FITTED WITH RCD ANY HEIGHT ACCEPTABLE ALTHOUGH THE UNIT IS 2,5M ABOVE THE HEIGHT OF THE POOL IT IS NOT ACCESSIBLE FOR SERVICE & SO BREAKS THE NEW REGULATIONS 2,5M 1) N.B. THE RCD IS AN EARTH LEAKAGE TRIP & ALTHOUGH NOT ALWAYS REQUIRED IT IS RECOMMENDED THAT IT IS USED ON ALL INSTALLATIONS. WHEN FITTED, A 30mA RCD SHOULD BE USED. 2)THE ISOLATOR FOR THE DEHUMIDIFIER MUST COMPLY TO THE APPROPRIATE IPX REGULATION page2 IF THE UNIT IS WITHIN 1,25M OF THE POOL HORIZONTALLY THEN IT MUST BE 2,5M ABOVE THE POOL SURFACE. SD139460 ISSUE 21 INSTALLATION INSTRUCTIONS MODELS DH30/33/50/55/60/A/AX/ARH/AP HEALTH & SAFETY WARNING As the Heat Pump contains electrical and rotational equipment, it is recommended that ONLY competent persons carry out any work on this type of machine (see guarantee). Isolate electrically before entering machine or removing panels. 13. It is recommended that isolating valves are fitted to enable isolation of the machine in the event of service. INSTALLATION - WALL MOUNTING ALL MODELS Complete water circuit as per diagrams overleaf. 1. Remove machine from packaging and locate fixing bracket. (a) Circulating pump must be sized to take into account the design flow rate of the machine plus the water system resistance. D DH30/33 RH DH50/55/60 RH Unit Flow Rate - l/min Unit Pressure Drop - m/hd A 8/12 1.0/2.2 12/16 1.0/2.0 . MODELS WITH L.P.H.W. FITTED B C 2. Locate bracket on wall in required position. Drill hole Ø 6.0mm (no. 10) by 60mm deep as shown at 'A'. Insert wall plug and screw bracket in place. 3. Set bracket level with spirit level 'D' as shown, drill through and fix it at 'B' with wall plug and screw. 4. Ensure bracket still level, tighten screws 'A' and 'B', finally drill and fix as above at position(s) 'C'. 5. Check all screws are tight. 6. Lift dehumidifier on to locating lugs on wall bracket. 7. Remove front cover as shown FIG 1. 14. Connect water circuit piping to 15mm stubs projecting from side of machine as per diagram below:15. It is recommended that isolating valves are fitted to enable isolation of the machine in the event of service. Complete water circuit as per diagrams overleaf. (a) Circulating pump must be sized to take into account the design flow rate of the machine plus the water system resistance. DH33 DH55 Unit Flow Rate - l/min Unit Pressure Drop - m/hd 5 0.7 5 0.7 WATER FLOW AS SHOWN 15mm STUBS FIG 1 WATER FLOW AS SHOWN 15mm STUBS DH33 HINGE AND LIFT COVER AWAY . DH55 12v REMOTE HUMIDISTAT OR THERMOSTAT CONNECTIONS REMOVE COVER FIXING SCREWS 16. Remove link wire from mains in terminal block marked 'Remote Control Interface'. Connect remote humidistat as shown below, ensure knob on humidistat in machine is set fully clockwise (ie maximum dehumidifcation). 8. Electrical supply to the unit must be sized according to data on serial number label paying special attention to I.E.E. regulations latest edition regarding the special conditions governing electrical supply to machines in potentially damp areas. 9. The electrical supply should be connected to the terminal block mounted on the side of the bracket supporting the compressor or on side panel for CALOTHERM versions Humidistat or Brown/red to 'live', blue/black to neutral and earth to the stud provided. Air stat (not 10. Fan mode switch (if fitted) can be set to cycle fan when humidistat senses demand but supplied) should be set to continuous to promote good air circulation and reduce Remote Control condensation. Interface Note that on models fitted with LPHW the fan(s) will start automatically whenever 250M MAX there is an air heating demand. On 'X' models fan(s) will stop during defrost cycle. 1mm SQ CABLE 11. Locate pipe from drip tray and run it away to waste. A short length of 10mm pipe is provided which should be led into a fixed waste pipe. Two pipe outlet holes 'P' MODELS WITH RESISTANCE HEATER are provided, one to rear of unit, one below the unit. 17. Connect remote air thermostat as shown above to mains in terminal block marked 'Remote Control Interface' 18. Ensure safety thermostat(s) below are set, ie push red button(s). 'RH' MODEL WITH HEAT RECLAIM TO WATER 12. Connect water circuit piping to 15mm stubs projecting from side of machine as per diagram below:- HEAT RECOVERED Safety thermostat press to reset (red button) FIG 2 WATER OUT HINGE AND LIFT COVER AWAY HEAT RECOVERED WATER IN REMOVE COVER FIXING SCREWS Remove cover to gain access to manual reset thermostat. 19. Replace front cover, turn on electrical supply and turn humidistat towards 'max'. (Unless remote humidistat fitted , see note 16 above) unit fan will start, followed 6 minutes later by the compressor. page3 SD139460 ISSUE 21 PLUMBING CIRCUITS HEAT RECOVERY 'RH' MODELS HEAT RECOVERY TO HOT WATER HEAT RECOVERY TO POOL/SPA DEHUMIDIFIED SPACE DEHUMIDIFIER COLD WATER FEED HOT WATER DRAIN OFF DRAIN DRAIN 3 P.S.I. NRV SANITISER PUMP CYLINDER STAT WATER PUMP WATER CIRCUIT COMPONENTS REQUIRED INSULATED DIRECT HOT WATER CYLINDER WATER PUMP THERMOSTAT PIPING INSULATED FILTER ELECTRICAL SUPPLY CIRCUITS HOT WATER CYLINDER INSULATED LPHW PLUMBING SCHEMATIC INCOMING SUPPLY CAPACITY TO SUIT PUMP AND DEHUMIDIFIER 3 WAY MOTORISED VALVE CONTROLLED BY CUSTOMERS THERMOSTAT E AUX FUSEBOARD N DEHUMIDIFIER L PUMP L ISOLATOR TO SUIT PUMP LPHW CONNECTIONS LOCATED ON DEHUM CABINET FLOW BALANCE VALVE BOILER RADIATORS IF FITTED FLOW METER N N L WATER PUMP SINGLE PHASE LOCAL ISOLATOR CAPACITY TO SUIT DEHUMIDIFIER WATER PUMP IS HEAT RECOVERY ,POOL/SPA FOR OR HOT WATER APPLICATIONS ONLY USER CHECK LIST OPERATION MACHINE NOT RUNNING AT ALL A normal humidistat setting (50-60% RH) is a mid way point on the knob provided. Minimum Air Temp DH 30/33/50/55/60 A = 15°C Minimum Air Temp DH 30/33/50/55/60 AX = 0°C Note :- On 'X' models fan stops during defrost. On machines with resistance heaters DH30/50/60 'P' heating control is governed by the remote mounted air thermostat , adjust to desired air temp, heater will run automatically as required. On machines with LPHW, fans will start automatically as required. MAINTENANCE a. Ensure air inlet/outlets are kept clear and clean. Filter kits available. b. Wipe clean with damp cloth or cleaning fluid suitable for fibreglass and/or PVC Note: The Reply Paid Warranty Registration Card must be returned to ensure the correct warranty is given. If you do not find a Registration Card with your machine please contact CALOREX Service Department giving your name address and serial number of your machine. A card will then be sent to you for completion. HEALTH & SAFETY WARNING As the Heat Pump contains electrical and rotational equipment, it is recommended that ONLY competent persons carry out any work on this type of machine (see guarantee) Isolate machine electrically before entering machine or removing panels. CHECK THE FOLLOWING :1. Is supply switched on. 2. Is supply fuse healthy 3. Turn humidistat knob fully clockwise. 4. Check air inlet and outlet for obstructions. 5. On 'P' models reset thermostat(s) see Fig 2 6. If, after carring out the above and waiting 1 hour, the machine does not start phone for service. MACHINE FAN ONLY RUNNING 7. Turn humidistat knob fully clockwise 8. Check air inlet and outlet for obstructions, if after 30 mins the machine has not restarted phone for service. WATER LEAKING FROM BASE OF UNIT 9. Check connection from machine to drain for blockages and clear accordingly, Check fall is adequate. 10. Check that machine is level both vertically and horizontally. The user check list should be carried out before initiating a service call. Do not attempt to interfere with any internal control settings as these have been factory calibrated and sealed. If in doubt or if advice is required, contact Calorex Service Dept. Telephone (01621) 857171 or 856611 PLEASE LEAVE INSTRUCTIONS FOR USER page4 SD139460 ISSUE 21 kW kW RESISTANCE HEATER ONLY TOTAL HEAT TO WATER kW kW kW DEHUM' (COMP & FAN) DEHUM & HEATER HEATER & FAN page5 kg 40/50 0.5 n/a n/a 52 700 15.8 4.4 3.4 10.0 230v50hz n/a n/a 0.75 0.05 n/a n/a n/a 40/50 0.5 n/a n/a 52 700 15.8 4.4 3.4 10.0 230v50hz n/a n/a 0.75 0.05 n/a n/a n/a 1.9 40/50 0.5 n/a n/a 52 700 15.8 12.7 11.7 20.0 230v50hz 2.05 2.75 0.75 0.05 n/a 2.0 2.89 1.9 30.0 1.25 DH30(7)AP/AXP 45/55 1.04 1.6 10 52 700 15.8 4.4 3.4 10.0 230v50hz n/a n/a 0.75 0.05 1.4 n/a n/a 0.5 30.0 1.25 2.5 2.5 1L/min=0.22gall/min e) IP rating for all units is IP45 f) R134a Global warming potential (GWP) 1300. f) R407c Global warming potential (GWP)1700 1m hd =1.4psi 65/80 1.64 1.5 14 54 1280 30.0 7.5 5.6 13.0 230v50hz n/a n/a 1.2 0.11 2.8 n/a n/a 0.65 60.0 1mm Wg =9.8Pa 60/75 0.8 AXP 0.75 AP n/a n/a 54 1280 30.0 24.2 22.3 32.0 230v50hz 4.11 5.2 1.2 0.11 n/a 4.0 5.55 3.5 60.0 d) Maximum operating conditions for AP versions air temp 32ºC and 62% RH 60/75 0.8 n/a n/a 54 1280 30.0 7.5 5.6 13.0 230v50hz n/a n/a 1.2 0.11 n/a n/a n/a 3.5 60.0 2.5 70/78 0.8 R134a n/a n/a 55 1750 30.0 23.0 22.2 33.0 230v50hz 4.18 5.1 1.1 0.16 n/a 4.0 6.0 2.2 50 2.1 DH50(7)/60(7)AX DH50(7)/60(7)AP/AXP DH50(7)/60(7)ARH *DH60AHP d) Maximum operating conditions air temp 35ºC and 90% RH c) Minimum air temperature on standard models 15°C and 0°C on defrost 'X' models b) Humidistat adjustable from 20% to 80% *a) These performance figures are based on air @ 36ºC, 60% RH 60/75 0.75 n/a n/a 54 1280 30.0 7.5 5.6 13.0 230v50hz n/a n/a 1.2 0.11 n/a n/a n/a 3.5 60.0 2.5 DH30(7)ARH DH50(7)/60(7)A a) These performance figures are based on air @ 30ºC, 60% RH & poolwater @ 28ºC and boiler water @ 80ºC WEIGHT UNPACKED/PACKED kg R407c m hd REFRIGERANT CHARGE PRESSURE DROP m3/h AIR FLOW dB/A AMP COMPRESSOR L.R.A. L/min AMP FULL LOAD AMPS WATER FLOW RATE AMP NOMINAL RUNNING AMPS NOISE LEVEL @ 3m AMP FUSE SUPPLY kW FAN ONLY NOMINAL POWER CONSUMED:- kW DEHUM & RESISTANCE HEATER 1.9 30.0 30.0 kW 1.25 1.25 L/hr DH30(7)A DH30(7)AX L/day DEHUMIDIFIER ONLY TOTAL HEAT TO AIR: DEHUMIDIFICATION MODEL 2.0 DATA SHEET SD139460 ISSUE 21 DH55(7)ARH 2.5 60.0 DH55(7)AX 2.5 60.0 DH55(7)A 2.5 60.0 DH33(7)ARH 1.25 30.0 1.25 30.0 1.25 30.0 L/day 5.4 5.0 2.8 6.5 5.0 n/a 6.5 5.0 n/a 3.4 3.0 1.4 3.9 3.0 n/a 3.9 3.0 n/a kW kW kW DEHUM & LPHW LPHW ONLY TOTAL HEAT TO WATER page6 740 48 14 1.5 5.0 1.8 0.85 1.64 65/80 740 48 n/a n/a 5.0 1.8 0.85 0.8 60/75 740 48 n/a n/a 5.0 1.8 0.85 0.76 60/75 440 48 10 1.6 5.0 1.1 0.5 1.04 45/55 440 48 n/a n/a 5.0 1.1 0.5 0.5 40/50 440 48 n/a n/a 5.0 1.1 0.5 0.5 40/50 dB/A L/min m hd L/min m hd l kg R407c kg NOISE LEVEL @ 3m WATER FLOW RATE PRESSURE DROP LPHW FLOW RATE LPHW PRESSURE DROP 1m hd = 1.4psi 1L/min = 0.22 gal/min e) Maximum operating conditions for AP versions air temp 32ºC and 62% RH f) IP rating for all units is IP45 g) R407c Global warming potential (GWP) 1700. 1mm Wg = 9.8Pa SEE NOTE d e) Maximum operating conditions air temp 35ºC and 90% RH d) Reduced LPHW output when DH operating is 1kW less on 33 model and 2KW less on 55 model c) Minimum air temperature on standard models 15°C and 0°C on defrost 'X' models b) Humidistat adjustable from 20% to 80% a) These performance figures are based on air @ 30ºC, 60% RH & poolwater @ 28ºC and boiler water @ 80ºC WEIGHT UNPACKED/PACKED REFRIGERANT CHARGE LPHW VOLUME 30.0 30.0 30.0 15.8 15.8 15.8 AMP m3/h 7.5 7.5 7.5 4.4 4.4 4.4 AMP FULL LOAD AMPS AIR FLOW 5.6 5.6 5.6 3.4 3.4 3.4 AMP NOMINAL RUNNING AMPS COMPRESSOR L.R.A. 13.0 13.0 13.0 10.0 10.0 10.0 AMP FUSE 1.2 230v50hz 1.2 230v50hz 1.2 230v50hz 0.75 230v50hz 0.75 230v50hz 0.75 230v50hz kW DEHUM' (COMP & FAN) SUPPLY 0.11 0.11 0.11 0.05 0.05 0.05 kW FAN ONLY NOMINAL POWER CONSUMED:- 0.65 3.5 3.5 0.5 1.9 1.9 kW DH33(7)A DH33(7)AX L/hr DEHUMIDIFIER ONLY TOTAL HEAT TO AIR: DEHUMIDIFICATION MODEL 2 DATA SHEET CONT SD139460 ISSUE 21 C L DF STAT FT DEHUMIDI STAT SH O/BL CYCLE 'SCHRAK' & 'FINDER' DELETED FROM RELAY TECASA NOTE ADDED BUTT CONNECTOR NOTE MODIFIED INTERCONTROL WIRING ADDED LPHW SWITCH TERMINAL CHG'D BUTTS USED ON TTW55 ONLY HARD KICK CAP ADDED RELAY NOTE CHANGED RELAY CHANGED VARIOUS WIRE COLOURS CHG'D 15 14 13 12 11 10 9 8 7 6 G/Y EARTH STUD C/N 946 955 955 962 1056 DH 1167 APPD GSM GSM GSM GSM CJW BJS MDW DH GSM KW KW 1173 1167/1 1477 1643 1642 C L DF STAT FT DEHUMIDI STAT SH O/BL CYCLE R/BL R DATE 28:07:97 18:05:98 29:06:96 05:11:98 25:09:03 24:05:04 17:05:07 24:07:07 28:08:07 17:06:10 10/08/11 16/09/11 K 9 7 RELAY A B R DEHUMIDISTAT DEFROST THERMOSTAT LPHW THERMOSTAT FAN MODE SWITCH HIGH PRESSURE SWITCH LOW PRESSURE SWITCH DELAY TIMER RELAY COMPRESSOR MOTOR FAN MOTOR COMPRESSOR CAPACITOR FAN CAPACITOR HARD KICK CAP/RELAY SOLENOID VALVE DEFROST THERMOSTAT/TIMER TRANSFORMER CALOREX HEAT PUMPS LTD U.C.C. SH FT TH S1 HP LP D K MC MV C1 C2/C3 C4 Y A T C 4 6 D TIMER FAN DIAPHRAGM /WALL PANEL BL R/B C1 COMP' CAP G/Y G/Y C4 FAN CAP C2 B R/B MV HARDKICK CAP/RELAY DH75/150 & AW175/350 ONLY GR/B GR G/Y TTW55 ONLY FAN MOTOR MV BUTT CONNECTORS FITTED ON TTW55 DH30/33/50/55 & 60 MACHINES TTW55/150 ONLY FAN CAP C3 N(L2) C3 C2 C1 FINISH MATERIAL HOLES TO BS 4500 E12 INSPECTION LEVEL DIMS TOLERANCE UNLESS SPECIFIED VIOLET GREEN V G B 6(7) GRUN VIOLETT WEIß ROT ROSA ORANGE GRAU BRUAN BLAU SCHWARZ FT 6 mins A 4 K VERT VIOLETTE BLANC ROUGE ROSE ORANGE GRIS MARRON BLEU NOIR 1 CYCLE DH30/33/50/55A/ARH/75/150D TTW33/55A --- CONT' DRG No. 1 SHT No APPD 1 (2) 30:5:95 DATE TH D372750 GSM DRAWN (1) 2 P (4) SH S1 NTS SCALE 1 CYCLE (SOPAC JAEGER) TECASA LPHW VERSION CHANGE FOR S1 FT SH G/Y GREEN/YELLOW GROEN/GELB VERT/JAUNE WHITE W WIRING DIAGRAM TITLE P RED PINK O R GREY ORANGE GR BLUE BROWN B BR HP LP D BLACK C BL MV MV R TTW55 ONLY MC S L(L1) DRG No. D372750 CONTINUOUS IF IN DOUBT ASK CIRCUIT DIAGRAM C4 (IF FITTED) HYGROSTAT HYGROSTAT THERMOSTAT DE DEGIVRAGE VEREISUNGSSCHUTZTHERMOSTAT PWW-STAT THERMOSTAT LPHW SELECTEUR DE MODE DU VENTILATEUR GEBLASESCHALTER REINITIALISATION DEFAUT HAUTE PRESSION HOCHDRUCKSCHALTER REINITIALISATION DEFAUT BASSE PRESSION NIEDERDRUCKSCHALTER TEMPORISATEUR VERZOGERUNGSRELAIS RELAIS RELAIS COMPRESSEUR KOMPRESSORMOTOR MOTEUR DU VENTILATEUR VENTILATORMOTOR CONDENSATEUR DU COMPRESSEUR KONDENSATOR KOMPRESSOR CONDENSATEUR DU VENTILATEUR KONDENSATOR VENTILATOR AUTOM. START KAPAZITOR COND./RELAI DE DEMARRAGE VANNE ELECTROMAGNETIQUE MAGNETVENTIL THERMOSTAT DE DEGIVRAGE TEMPORISE ABTAUTHERMOSTAT/-UHR TRANSFORMATOR TRANSFORMATEUR FOR DH30/33/TTW33 CONNECT BROWN WIRES TO TERM No7 (RELAY SD219250) R BR BR CONNECTIONS FOR DH/TTW50/55/60/75/150 AS SHOWN. (RELAY SD092151) BR O CONT' G/Y B R/BL P ROCKER SWITCH S1 DRAWING CHANGE AND LPHW DETAIL ADDED WIRE COLOUR REFS CLARIFIED 16 ISS RELAY SD219250 WAS SD154650 DETAIL OF WIRING CHANGE FOR LPHW VERSIONS BR V R/BL ROCKER SWITCH CONT' BR 17 (1) (2) (4) LPHW STAT O 1 BR 2 V P TH (SOPAC JAEGER) TECASA TERM'BLOCK L (L1) N (L2) B G/Y R(P) BR GR S(A) LP SWITCH W W HP SWITCH R/O R/O FAN MOTOR W(BL) BL COMPRESSOR MC B BR BL WIRE FAN DIRECTLY TO COMPONENTS W G/Y P B C B BR W E (GRO) BR O page7 W R W/BL WIRES NOT CONNECTED (TWIN FAN ASSY ONLY) R B BL B ON MACHINES EXCEPT TTW55 LABEL D380750 ISS14 CONTINUOUS DO NOT SCALE PRINT OVERLOAD PROTECTOR 3.0 WIRING DIAGRAMS SD139460 ISSUE 21 B C/N BUTTS USED ON TTW55 ONLY HARD KICK CAP ADDED RELAY NOTE CHANGED RELAY CHANGED 10 9 8 DRAWING CHANGE GSM APPD 955 LPHW SWITCH TERMINAL CHG'D 11 7 955 INTERCONTROL WIRING ADDED 12 962 1056 1167 1173 BUTT CONNECTOR NOTE MODIFIED 13 GSM GSM CJW BJS DH MDW DH 1167/1 TECASA NOTE ADDED GSM 1477 15 'SCHRAK' & 'FINDER' DELETED FROM RELAY 14 KW KW 1642 1643 ISS W W L R BR DEHUM STAT SH C BR R 4 6 R/BL R/O R/O B 7 A K RELAY 9 D TIMER /WALL PANEL DIAPHRAGM FAN C1 B BL R/B COMP' CAP BL C4 16/09/11 DATE 18:05:98 29:06:96 05:11:98 25:09:03 24:05:04 17:05:07 24:07:07 28:08:07 17:06:10 10/09/11 R BL R DEHUMIDISTAT DEFROST THERMOSTAT LPHW THERMOSTAT FAN MODE SWITCH HIGH PRESSURE SWITCH LOW PRESSURE SWITCH DELAY TIMER RELAY COMPRESSOR MOTOR FAN MOTOR COMPRESSOR CAPACITOR FAN CAPACITOR HARD KICK CAP/RELAY SOLENOID VALVE DEFROST THERMOSTAT/TIMER TRANSFORMER CALOREX HEAT PUMPS LTD U.C.C. C SH FT TH S1 HP LP D K MC MV C1 C2/C3 C4 Y A T B R/BL GR R/B HARDKICK CAP/RELAY DH75/150 & AW175/350 ONLY C2 FAN CAP B BR GR MV W(BL) BL FAN MOTOR GR/B G/Y TTW55/150 ONLY MACHINES FITTED ON TTW55/ DH30/33/50/55 & 60 BUTTS CONNECTORS C3 FAN CAP G/Y FAN MOTOR MV TTW55 ONLY N(L2) C3 C2 C1 Y MC C4 (IF FITTED) FINISH MATERIAL HOLES TO BS 4500 E12 INSPECTION LEVEL DIMS TOLERANCE UNLESS SPECIFIED R C MV TTW55 ONLY MV S DH30/33/50/55AX/75/150D TTW33/55AX B 3 2 SH 1 CYCLE GRUN VIOLETT WEIß ROT ROSA ORANGE GRAU BRUAN BLAU SCHWARZ 6(7) TECASA BLEU NOIR TH 1 (2) 2 P GRIS VERT VIOLETTE BLANC ROUGE ROSE ORANGE --- 1 DRG No. CONT' SHT No APPD D372751 GSM DRAWN 31:5:95 DATE 1 S1 NTS SCALE CYCLE SH CHANGE FOR LPHW VERSION (SOPAC JAEGER) (4) (1) A MARRON 4 1 S1 CONTINUOUS D372751 G/Y GREEN/YELLOW GROEN/GELB VERT/JAUNE GREEN WHITE W G RED VIOLET PINK P R V GREY BROWN ORANGE BR O BLUE B GR BLACK 6 mins BL HP LP D A 4 K L(L1) DRG No. CIRCUIT DIAGRAM IF IN DOUBT ASK WIRING DIAGRAM TITLE HYGROSTAT HYGROSTAT VEREISUNGSSCHUTZTHERMOSTAT THERMOSTAT DE DEGIVRAGE PWW-STAT THERMOSTAT LPHW GEBLASESCHALTER SELECTEUR DE MODE DU VENTILATEUR HOCHDRUCKSCHALTER REINITIALISATION DEFAUT HAUTE PRESSION NIEDERDRUCKSCHALTER REINITIALISATION DEFAUT BASSE PRESSION VERZOGERUNGSRELAIS TEMPORISATEUR RELAIS RELAIS KOMPRESSORMOTOR COMPRESSEUR VENTILATORMOTOR MOTEUR DU VENTILATEUR KONDENSATOR KOMPRESSOR CONDENSATEUR DU COMPRESSEUR KONDENSATOR VENTILATOR CONDENSATEUR DU VENTILATEUR AUTOM. START KAPAZITOR COND./RELAI DE DEMARRAGE MAGNETVENTIL VANNE ELECTROMAGNETIQUE ABTAUTHERMOSTAT/-UHR THERMOSTAT DE DEGIVRAGE TEMPORISE TRANSFORMATOR TRANSFORMATEUR FOR DH30/33/TTW33 CONNECT BROWN WIRES TO TERM No7 (RELAY SD219250) R Y B DF VALVE CONNECTIONS FOR DH/TTW50/55/60/75/150 AS SHOWN. (RELAY SD092151) DF STAT/ TIMER RELAY SD219250 WAS SD154650 C L SH DEHUM STAT 4 3 R A 1 2 BL B CYCLE CONT' O G/Y ROCKER SWITCH S1 R(P) WIRE COLOURS REFS CLARIFIED 2 1 3 4 A DF STAT/ TIMER BR G/Y 17 BL R CYCLE O STAT ROCKER SWITCH O S1 BR V CONT' P EARTH STUD S(A) BR LP SWITCH P HP SWITCH B COMPRESSOR MC WIRES NOT CONNECTED (TWIN FAN ASSY ONLY) B WIRE FAN DIRECTLY TO COMPONENTS BL ON MACHINES EXCEPT TTW55 W B BR C B 16 JAEGER) ( SOPAC TECASA LPHW (2) 1 (4) 2 (1) P TH DETAIL OF WIRING CHANGE FOR LPHW VERSION L (L1) BR B R W/R N (L2) W/R R/BL E (GRO) R/BL W/BL G/Y W page8 BR W G/Y LABEL D380751 ISS14 CONTINUOUS DO NOT SCALE PRINT OVERLOAD PROTECTOR 3 WIRING DIAGRAMS CONT SD139460 ISSUE 21 L (L1) P TECASA V BUTTS ADDED FOR TRANS' ON P.B. HARD KICK CAP ADDED 8 7 DRAWING CHANGE BUTTS USED ON TTW55 ONLY 9 ISS LPHW SWITCH TERMINAL CHG'D INTERCONTROL WIRING ADDED 11 10 TECASA NOTE ADDED BUTT CONNECTION NOTE MODIFIED GSM APPD C/N CJW CJW BJS DH MDW DH GSM KW KW L R/O R BR R D TIMER B 4 7 A 9 RELAY 6 K C4 FAN DIAPHRAGM /WALL PANEL HARDKICK CAP/RELAY DH75/150 & AW175/350 ONLY DATE 05:11:98 08:11:02 25:09:03 24:05:04 17:05:07 24:07:07 28:08:07 17:06:10 10/08/11 16/09/11 R DEHUMIDISTAT DEFROST THERMOSTAT LPHW THERMOSTAT FAN MODE SWITCH HIGH PRESSURE SWITCH LOW PRESSURE SWITCH DELAY TIMER RELAY COMPRESSOR MOTOR FAN MOTOR COMPRESSOR CAPACITOR FAN CAPACITOR HARD KICK CAP/RELAY SOLENOID VALVE DEFROST THERMOSTAT/TIMER TRANSFORMER CALOREX HEAT PUMPS LTD U.C.C. C SH FT TH S1 HP LP D K MC MV C1 C2/C3 C4 Y A T FOR DH30/33/TTW33 CONNECT BROWN WIRES TO TERM No7 (RELAY SD219250) CONNECTIONS FOR DH/TTW50/55/60/75/150 AS SHOWN (RELAY SD092151) FT C SH O/BL DF STAT O R/BL CYCLE G/Y CONT' R(P) DEHUMIDI STAT V BR 962 1015 1056 1167 1173 1167/1 14 13 1477 'SCHRAK' & 'FINDER' DELETED FROM RELAYS 12 1643 WIRE COLOUR REFS CLARIFIED 1642 15 C L DF STAT FT G/Y RELAY SD219250 WAS SD154650 DEHUMIDI STAT SH O/BL CYCLE B ROCKER SWITCH S1 EARTH STUD S(A) W W G/Y FAN MOTOR A 7 4 B 9 6 0 RELAY K GR 12V COIL GR/B B FAN CAP C2 R/B B MV TRANSFORMER T BUTT CONNECTOR 12v 230v TTW55/150 ONLY MACHINES DH30/33/50/55 & 60 BUTT CONNECTORS FITTED ON TTW55/ FAN CAP C3 G/Y TTW55 ONLY FAN MOTOR MV B C3 C2 C1 FINISH HOLES TO BS 4500 E12 INSPECTION LEVEL DIMS MV GREY GREEN G K 4 1 A GRUN VIOLETT WEIß ROT ROSA ORANGE GRAU BRUAN BLAU SCHWARZ FT 6 mins B 6(7) SH K BLEU NOIR 1 FT CYCLE VERT VIOLETTE BLANC ROUGE ROSE ORANGE GRIS MARRON 7 B DH30/33/55A/ARH/75/150D TTW33/55A WITH REMOTE HUMIDISTAT --- CONT' DRG No. 1 SHT No APPD S1 1 LABEL D380752 ISS15 S1 NTS SCALE CYCLE 21:11:95 DATE TH 1 (2) 2 P TECASA (SOPAC JAEGER) (4) (1) SH CHANGE FOR LPHW VERSION D372752 GSM DRAWN G/Y GREEN/YELLOW GROEN/GELB VERT/JAUNE WHITE VIOLET V RED W PINK P R ORANGE BROWN BR GR O BLUE B HP LP D A 4 BLACK C BL MV TTW55 ONLY R S T D372752 L(L1) DRG No. 12V SIDE CIRCUIT DIAGRAM IF IN DOUBT ASK WIRING DIAGRAM MC C4 (IF FITTED) N(L2) HYGROSTAT HYGROSTAT VEREISUNGSSCHUTZTHERMOSTAT THERMOSTAT DE DEGIVRAGE PWW-STAT THERMOSTAT LPHW GEBLASESCHALTER SELECTEUR DE MODE DU VENTILATEUR HOCHDRUCKSCHALTER REINITIALISATION DEFAUT HAUTE PRESSION NIEDERDRUCKSCHALTER REINITIALISATION DEFAUT BASSE PRESSION VERZOGERUNGSRELAIS TEMPORISATEUR RELAIS RELAIS KOMPRESSORMOTOR COMPRESSEUR VENTILATORMOTOR MOTEUR DU VENTILATEUR KONDENSATOR KOMPRESSOR CONDENSATEUR DU COMPRESSEUR KONDENSATOR VENTILATOR CONDENSATEUR DU VENTILATEUR AUTOM. START KAPAZITOR COND./RELAI DE DEMARRAGE MAGNETVENTIL VANNE ELECTROMAGNETIQUE ABTAUTHERMOSTAT/-UHR THERMOSTAT DE DEGIVRAGE TEMPORISE TRANSFORMATOR TRANSFORMATEUR TOLERANCE UNLESS SPECIFIED TITLE MATERIAL V COMP' CAP C1 P LP SWITCH W(BL) BL HP SWITCH B BL C BL WIRE FAN DIRECTLY TO COMPONENTS CONTINUOUS ON MACHINES EXCEPT TTW55 REMOTE CONTROL INTERFACE DO NOT SCALE PRINT WIRES NOT CONNECTED (TWIN FAN ASSY ONLY) R B BR COMPRESSOR MC P 16 V (SOPAC JAEGER) R/BL ROCKER SWITCH CONT' DETAIL OF WIRING CHANGE FOR LPHW VERSIONS LPHW STAT O (2) 1 BR (4) 2 V (1) P TH P O BR B G/Y FIT WIRE LINK WHEN REMOTE NOT USED BR W/BL N (L2) O R/O BR E (GRO) R R/B W B TERM'BLOCK W BL P BR BR G/Y P W BR GR B R/BL BR P page9 O REMOTE CONTROL INTERFACE CONTINUOUS OVERLOAD PROTECTOR 3 WIRING DIAGRAMS CONT SD139460 ISSUE 21 L (L1) N (L2) 1 4 1477 1167/1 DRAWING CHANGE 9 C/N 1167 INTERCONTROL WIRING ADDED LPHW SWITCH TERMINAL CHG'D 10 ISS 1173 11 TECASA NOTE ADDED 13 'SCHRAK' & 'FINDER' DELETED FROM RELAY 12 1642 1643 RELAY SD219259 WAS SD154650 C L SH DEHUM STAT WIRE COLOUR REFS CLARIFIED A DF STAT/ TIMER 2 3 O KW APPD BJS DH MDW DH GSM KW R/BL BR W L W SH DEHUMIDI STAT C V R BR R BR D 4 RELAY 6 R/O TIMER 7 A K 9 B FAN DIAPHRAGM /WALL PANEL G/Y C4 DATE 24:05:04 17:05:07 24:07:07 28:08:07 17:06:10 10/08/11 16/09/11 DF VALVE Y R DEHUMIDISTAT DEFROST THERMOSTAT LPHW THERMOSTAT FAN MODE SWITCH HIGH PRESSURE SWITCH LOW PRESSURE SWITCH DELAY TIMER RELAY COMPRESSOR MOTOR FAN MOTOR COMPRESSOR CAPACITOR FAN CAPACITOR HARD KICK CAP/RELAY SOLENOID VALVE DEFROST THERMOSTAT/TIMER TRANSFORMER CALOREX HEAT PUMPS LTD U.C.C. C SH FT TH S1 HP LP D K MC MV C1 C2/C3 C4 Y A T COMP' CAP C1 P LP SWITCH R/O FOR DH30/33/TTW33 CONNECT BROWN WIRES TO TERM No7 (RELAY SD219250) CONNECTIONS FOR DH/TTW50/55/60/75/150 AS SHOWN (RELAY SD092151) 4 DF STAT/ TIMER A 1 3 O 2 15 BL R B CYCLE G/Y R 14 (SOPAC JAEGER) TECASA R(P) BL B CYCLE P S1 CONT' LPHW STAT O ROCKER SWITCH (2) 1 S1 BR BR (4) 2 V (1) P CONT' TH B ROCKER SWITCH EARTH STUD P W O BR B DETAIL OF WIRING CHANGE FOR LPHW VERSION FIT WIRE LINK WHEN REMOTE NOT FITTED REMOTE CONTROL INTERFACE S(A) W/R V GR/B BL FAN MOTOR A 9 0 B R/B 12v 230v BUTT CONNECTORS FITTED ON TTW55/ DH30/33/50/55 & 60 MACHINES BUTT CONNECTOR TRANSFORMER T TTW55/150 ONLY FAN CAP C3 G/Y TTW55 ONLY FAN MOTOR MV C4 C1 C3 C2 (IF FITTED) N(L2) FINISH MATERIAL HOLES TO BS 4500 E12 INSPECTION LEVEL DIMS TOLERANCE UNLESS SPECIFIED MC MV TTW55 ONLY MV HP LP D R S 6 mins C VIOLET GREEN V G DH30/33/50/55AX/75/150 TTW33/55AX WITH REMOTE HUMIDISTAT K SH 4 1 A GRUN VIOLETT WEIß ROT ROSA ORANGE GRAU BRUAN BLAU SCHWARZ 1 CYCLE 3 2 7 B 4 1 D372753 (1) BLEU NOIR TH 1 (2) 2 P (4) GRIS VERT VIOLETTE BLANC ROUGE ROSE ORANGE --- CONT' GSM DRAWN APPD DATE 22:11:95 DRG No. D372753 1 SHT No 1 S1 NTS SCALE CYCLE (SOPAC JAEGER) TECASA SH CHANGE FOR LPHW VERSION MARRON A S1 CONTINUOUS L(L1) DRG No. REMOTE CONTROL INTERFACE G/Y GREEN/YELLOW GROEN/GELB VERT/JAUNE RED PINK WHITE P R W GREY ORANGE BROWN BR O BLUE B GR BLACK B 6(7) T 12V SIDE BL Y A 4 K CIRCUIT DIAGRAM WIRING DIAGRAM TITLE HYGROSTAT HYGROSTAT VEREISUNGSSCHUTZTHERMOSTAT THERMOSTAT DE DEGIVRAGE PWW-STAT THERMOSTAT LPHW GEBLASESCHALTER SELECTEUR DE MODE DU VENTILATEUR HOCHDRUCKSCHALTER REINITIALISATION DEFAUT HAUTE PRESSION NIEDERDRUCKSCHALTER REINITIALISATION DEFAUT BASSE PRESSION VERZOGERUNGSRELAIS TEMPORISATEUR RELAIS RELAIS KOMPRESSORMOTOR COMPRESSEUR VENTILATORMOTOR MOTEUR DU VENTILATEUR KONDENSATOR KOMPRESSOR CONDENSATEUR DU COMPRESSEUR KONDENSATOR VENTILATOR CONDENSATEUR DU VENTILATEUR AUTOM. START KAPAZITOR COND./RELAI DE DEMARRAGE MAGNETVENTIL VANNE ELECTROMAGNETIQUE ABTAUTHERMOSTAT/-UHR THERMOSTAT DE DEGIVRAGE TEMPORISE TRANSFORMATOR TRANSFORMATEUR 7 6 RELAY K 12V COIL 4 B FAN CAP C2 BR B MV WIRE FAN DIRECTLY TO COMPONENTS ON DH50/55/60 MSCHINES W(BL) BL HP SWITCH B B IF IN DOUBT ASK BR BR C W B BL COMPRESSOR MC B O G/Y W/R W/BL E (GRO) G/Y R/BL R/B W TERM'BLOCK R R HARDKICK CAP/RELAY DH75/150 & AW175/350 ONLY BL WIRES NOT CONNECTED (TWIN FAN ASSY ONLY) R BL P B BR G/Y GR P R/BL BR P GR B B O page10 V LABEL D380753 ISS15 CONTINUOUS OVERLOAD PROTECTOR 3 WIRING DIAGRAMS CONT SD139460 ISSUE 21 L (L1) N (L2) 'SCHRACK' & 'FINDER' DELETED FROM RELAY 10 ISS DRAWING CHANGE GSM APPD C/N GSM 955 5 946 GSM 955 RELAY NOTE CHANGED RELAY & WIRING CHANGES 6 4 VARIOUS WIRE COLOURS CHANGED CJW CJW GSM MDW 1477 1643 1173 KW KW 1642 1056 R 9 B RELAY 7 A K 4 W/BL 6 C L DF STAT FT 16/09/11 DATE 1:8:97 9:6:98 29:6:98 08:11:02 25:09:03 24:07:07 17:06:10 10/08/11 3 6 4 C1 COMP' CAP 0 GR/B 12v 230v R FINISH MATERIAL DEHUMIDISTAT DEFROST THERMOSTAT LPHW THERMOSTAT FAN MODE SWITCH HIGH PRESSURE SWITCH LOW PRESSURE SWITCH DELAY TIMER RELAY COMPRESSOR MOTOR FAN MOTOR COMPRESSOR CAPACITOR FAN CAPACITOR HARD KICK CAP/RELAY SOLENOID VALVE DEFROST THERMOSTAT/TIMER TRANSFORMER RESISTANCE HEATER THERMAL CUTOUT 7 9 12V COIL B RELAY A K SH FT TH S1 HP LP D K MC MV C1 C2/C3 C4 Y A T RH TC WIRES NOT CONNECTED (TWIN FAN ASSY ONLY) DIAPHRAGM FAN G/Y MV FAN MOTOR G/Y MACHINES DH30/50 & 60AP FITTED ON TTW50AP/ C3 C2 C1 RH MC DH50 ONLY DH30/50 N(L2) BUTT CONNECTORS TTW50AP ONLY FAN CAP C3 TTW50AP ONLY FAN MOTOR MV MV MV TC TC C ONLY TTW50AP R S HOLES TO BS 4500 E12 INSPECTION LEVEL DIMS IF IN DOUBT ASK DH30/50AP TTW50AP RESISTANCE HEATERS WIRING DIAGRAM GREEN G GRUN VIOLETT WEIß ROT ROSA NOIR VERT VIOLETTE BLANC ROUGE ROSE ORANGE GRIS MARRON BLEU LABEL D380754 ISS12 --- DRG No. 1 CONT' APPD DATE 23:11:95 D372754 GSM DRAWN NTS SCALE G/Y GREEN/YELLOW GROEN/GELB VERT/JAUNE WHITE VIOLET V RED W PINK P R ORANGE GRAU BRUAN GREY BROWN ORANGE BR O BLUE GR BLAU BLACK SCHWARZ S1 CONT' SH B A B 1 9 3 6 CYCLE 1 4 7 K 12V SIDE T D372754 L(L1) DRG No. BL FT 6 mins B 6(7) SHT No HP LP D A 4 K CIRCUIT DIAGRAM HYGROSTAT HYGROSTAT VEREISUNGSSCHUTZTHERMOSTAT THERMOSTAT DE DEGIVRAGE SELECTEUR DE MODE DU VENTILATEUR PWW-STAT GEBLASESCHALTER THERMOSTAT LPHW HOCHDRUCKSCHALTER REINITIALISATION DEFAUT HAUTE PRESSION NIEDERDRUCKSCHALTER REINITIALISATION DEFAUT BASSE PRESSION VERZOGERUNGSRELAIS TEMPORISATEUR RELAIS RELAIS KOMPRESSORMOTOR COMPRESSEUR VENTILATORMOTOR MOTEUR DU VENTILATEUR KONDENSATOR KOMPRESSOR CONDENSATEUR DU COMPRESSEUR KONDENSATOR VENTILATOR CONDENSATEUR DU VENTILATEUR AUTOM. START KAPAZITOR COND./RELAI DE DEMARRAGE MAGNETVENTIL VANNE ELECTROMAGNETIQUE ABTAUTHERMOSTAT/-UHR THERMOSTAT DE DEGIVRAGE TEMPORISE TRANSFORMATOR TRANSFORMATEUR ELEKTROHEIZUNG RESISTANCE DE CHAUFFAGE UBERHITZUNGSSCHUTZ PROTECTION THERMIQUE TOLERANCE UNLESS SPECIFIED TOLERANCE UNLESS SPECIFIED TITLE BUTT CONNECTOR TRANSFORMER T FAN CAP C2 B G/Y FAN DIRECTLY TO COMPONENTS BR GR DH30/50 1 CALOREX HEAT PUMPS LTD U.C.C. C D TIMER FOR DH30AP CONNECT BROWN WIRES TO TERM No7 (RELAY SD219250) 7 BUTTS ADDED FOR P,BR,B ON TRANSFORMER 1015 THERMAL CUTOUTS SHOWN FOR DH50AXP 8 BUTTS FOR FAN CONNS USED ON TTW50AP ONLY 2ND FAN MOTOR & C3 ADDED FOR TTW50AP 9 BUTT CONNECTOR NOTE MODIFIED RELAY SD219250 WAS SD154650 WIRE COLOUR REFS CLARIFIED G/Y 11 BR BR DEHUMIDI STAT SH O/BL CONNECTIONS FOR DH50AP AS SHOWN (RELAY SD092151) BR O CYCLE R/BL ROCKER SWITCH CONT' BR WHITE SILICON (2.5) EARTH STUD P 12 P O BR BR 2,5 B G/Y B BR E (GRO) O/BL TERM'BLOCK REMOTE CONTROL INTERFACE W G/Y R R/O R/O R(P) W S(A) WHITE SILICON (2.5) P LP SWITCH P HP SWITCH BL W BL COMPRESSOR MC R/B B ON MACHINES EXCEPT TTW50AP WIRE B MANUAL RESET AUTO RESET RED SILICON (2.5) O B C THERMAL CUTOUTS O/BL BR B R/BL R/B BL RESISTANCE HEATERS DH50 ONLY P B BR BR 2,5 BL GR B W W BR DO NOT SCALE PRINT B R BR P page11 O R REMOTE CONTROL INTERFACE OVERLOAD PROTECTOR 3 WIRING DIAGRAMS CONT SD139460 ISSUE 21 BUTT CONNECTOR NOTE MODIFIED BUTTS FOR FAN CONNS USED ON TTW50AXP ONLY. 2ND FAN & FAN CAP ADDED FOR TTW50AXP 9 8 BUTTS ADDED FOR P,B,BR ON TRANSFORMER 'SCHRACK' & 'FINDER' DELETED FROM RELAY 10 3 R DF STAT/ TIMER A 2 B 1 4 C/N DRAWING CHANGE GSM APPD 934 GSM GSM SYMBOLS & KEY TABLE ADDED 3 ISS 955 946 RELAY & WIRING CHANGES VARIOUS WIRE COLOURS CHANGED 5 4 GSM CJW CJW MDW GSM KW KW RELAY NOTE CHANGED 955 1015 1056 1173 1477 1643 1642 R BR BR 9 4 7 K RELAY 6 SH DH STAT BR O CYCLE BR CONT' R A B W/BL D TIMER DATE 3:7:96 1:8:97 10:6:98 29:6:98 08:11:02 25:09:03 24:07:07 17:06:10 10/08/11 16/09/11 RELAY K O W FAN DIAPHRAGM 3 6 9 B 7 A 12v 230v R/B COMPRESSOR MOTOR FAN MOTOR FAN CAPACITOR HARD KICK CAP/RELAY SOLENOID VALVE DEFROST THERMOSTAT/TIMER TRANSFORMER RESISTANCE HEATER THERMAL CUTOUT FINISH MATERIAL C4 Y A T RH TC C2/C3 COMPRESSOR CAPACITOR MV C1 MC DELAY TIMER RELAY LOW PRESSURE SWITCH D K HIGH PRESSURE SWITCH LP FAN MODE SWITCH HP LPHW THERMOSTAT S1 DEFROST THERMOSTAT DEHUMIDISTAT BUTT CONNECTOR TRANSFORMER T FAN CAP C2 B MV FAN MOTOR TTW50AXP ONLY FAN MOTOR MV WIRE DIRECTLY TO COMPONENTS ON MACHINES EXCEPT TTW50AXP TH FT SH 0 COMP' CAP C1 4 12V COIL R G/Y 1 CALOREX HEAT PUMPS LTD U.C.C. C FOR DH30AXP CONNECT BROWN WIRES TO TERM No7 (RELAY SD219250) 6 7 THERMAL CUTOUTS ADDED FOR DH50AXP BR ROCKER SWITCH CONNECTIONS FOR DH50AXP AS SHOWN (RELAY SD092151) WIRE COLOUR REFS CLARIFIED G/Y WHITE SILICON (2.5) R(P) W LP SWITCH R/O R/O HP SWITCH RED SILICON (2.5) DH30/50 GR/B 3rd ANGLE PROJECTION B R/BL C EARTH STUD S(A) 11 G/Y RELAY SD219250 WAS SD154650 DF VALVE Y P O BR 2.5 BR B G/Y P 12 REMOTE CONTROL INTERFACE L (L1) N (L2) E (GRO) B TERM'BLOCK R B W/R BL BR GR COMPRESSOR MC W/R W BL R THERMAL CUTOUTS AUTO RESET MANUAL RESET BR W HOLES TO BS 4500 E12 INSPECTION LEVEL R HYGROSTAT MV TC TC C THERMOSTAT LPHW THERMOSTAT DE DEGIVRAGE DH50 ONLY RH DH30/50 RH MC S DIMS DH30/50AXP RESISTANCE HEATERS WIRING DIAGRAM TITLE COND./RELAI DE DEMARRAGE VANNE ELECTROMAGNETIQUE THERMOSTAT DE DEGIVRAGE TEMPORISE TRANSFORMATEUR RESISTANCE DE CHAUFFAGE PROTECTION THERMIQUE CONDENSATEUR DU VENTILATEUR CONDENSATEUR DU COMPRESSEUR MOTEUR DU VENTILATEUR COMPRESSEUR RELAIS TEMPORISATEUR REINITIALISATION DEFAUT BASSE PRESSION REINITIALISATION DEFAUT HAUTE PRESSION A 4 Y P GRUN VIOLETT WEIß ROT ROSA ORANGE GRAU BRUAN BLAU SCHWARZ ONLY 3 2 MV TTW50AP 1 4 A VERT VIOLETTE BLANC ROUGE ROSE ORANGE GRIS MARRON BLEU NOIR 1 S1 --- CONT' GSM DRAWN APPD 23:11:95 DATE NTS SCALE G/Y GREEN/YELLOW GROEN/GELB VERT/JAUNE GREEN G WHITE VIOLET V W RED PINK O R GREY ORANGE GR B A L(L1) D372755 DRG No. D372755 1 BLUE BLACK BROWN SH 3 6 9 CYCLE CONT' 1 4 K 7 12V SIDE T DRG No. BR B BL C3 6 mins SHT No HP B 6(7) LP D K CIRCUIT DIAGRAM IF IN DOUBT ASK SELECTEUR DE MODE DU VENTILATEUR C2 TOLERANCE UNLESS SPECIFIED AUTOM. START KAPAZITOR MAGNETVENTIL ABTAUTHERMOSTAT/-UHR TRANSFORMATOR ELEKTROHEIZUNG UBERHITZUNGSSCHUTZ KONDENSATOR VENTILATOR KONDENSATOR KOMPRESSOR VENTILATORMOTOR KOMPRESSORMOTOR RELAIS VERZOGERUNGSRELAIS NIEDERDRUCKSCHALTER HOCHDRUCKSCHALTER GEBLASESCHALTER PWW-STAT VEREISUNGSSCHUTZTHERMOSTAT FAN CAP C3 HYGROSTAT MACHINES FITTED ON TTW50AXP/ DH30/50 & 60 C1 N(L2) BUTT CONNECTORS BL DH50 ONLY WIRES NOT CONNECTED (TWIN FAN ASSY ONLY) B B W W R/BL BR WHITE SILICON (2.5) R/B BL P P BL B BL B BR 2.5 G/Y R/B G/Y B BR RESISTANCE HEATER LABEL D380755 ISS12 DO NOT SCALE PRINT P R GR BR P page12 O REMOTE CONTROL INTERFACE OVERLOAD PROTECTOR 3 WIRING DIAGRAMS CONT SD139460 ISSUE 21 6 5 4 P O BR BR B G/Y G/Y S(A) R(P) G/Y BUTT APPD C/N DRAWING CHANGE ---- CJW MDW 4 ---- ISS 9 B D TIMER DATE 09:10:02 25:09:03 24:07:07 7 A K1 RELAY 6 3 SILICON WIRE SIZE ADDED 1173 RED BR W/BL 1056 + BROWN WIRE MOVED TO TERM 7 RELAY K3 BUTT CONN. ADDED BUTT HP SWITCH C H BLUE G/Y WHITE SILICON (2,5) G/Y EARTH STUD WIRE COLOUR ON TERM 6 KI RELAY WAS BLK REMOTE HUMIDISTAT P COMPRESSOR MC R BR LP SWITCH BUTT BLU 6 9 B 4 7 A RED/BLU P 3 1 RELAY K3 12V COIL BLU CALOREX HEAT PUMPS LTD U.C.C. C R/O R/O P LOWER G/Y R 3 B 9 6 H 12V FINISH MATERIAL HP PINK SWITCH C P 2001 A 7 4 1 RELAY K2 12V COIL C1 COMP' CAP MV FAN MOTOR GR/B 300 PSI FAN DIAPHRAGM BUTT TERMINAL WHITE FLYING LEAD MANUAL RESET 400 PSI BLU BUTT LINK RED SILICON C B 4 BUTTS REMOVED FOR FAN 5 L (L1) 3 2 INTERFACE N (L2) 1 RED/BLU O/BL W/BL TERM'BLOCK R RED SILICON (2,5) TERMINAL WHITE SILICON (2,5) UPPER THERMAL CUTOUTS RESISTANCE HEATERS P OVERLOAD PROTECTOR R/B E (GRO) REMOTE BLK W/BL B GRN/ REMOTE THERMOSTAT CONTROL O/BL BR B RED G/Y BR BR 2,5 3rd ANGLE PROJECTION FAN CAP C2 0 12v 230v BL R PINK RED WHITE VIOLET GREEN O P R W V G GRAU GRUN VIOLETT WEIß ROT ROSA ORANGE VERT C2 HOLES TO BS 4500 E12 INSPECTION LEVEL DIMS TOLERANCE UNLESS SPECIFIED CONDENSATEUR DU COMPRESSEUR CONDENSATEUR DU VENTILATEUR HARD KICK CAP/RELAY C4 THERMOSTAT DE DEGIVRAGE TEMPORISE THERMAL CUTOUT RESISTANCE HEATER DH60AHP (134a) WIRING DIAGRAM TITLE TC RH PROTECTION THERMIQUE RESISTANCE DE CHAUFFAGE --- CONT' DRG No. 1 SHT No APPD D372756 MJH DRAWN 09:08:01 DATE ALL SHARP EDGES AND BURRS TO BE REMOVED UBERHITZUNGSSCHUTZ ELEKTROHEIZUNG TRANSFORMATEUR VANNE ELECTROMAGNETIQUE TRANSFORMATOR ABTAUTHERMOSTAT/-UHR TRANSFORMER DEFROST THERMOSTAT/TIMER A T MAGNETVENTIL SOLENOID VALVE Y COND./RELAI DE DEMARRAGE MOTEUR DU VENTILATEUR KONDENSATOR VENTILATOR FAN CAPACITOR C2/C3 AUTOM. START KAPAZITOR COMPRESSEUR KONDENSATOR KOMPRESSOR COMPRESSOR CAPACITOR C1 RELAIS VENTILATORMOTOR FAN MOTOR MV TEMPORISATEUR KOMPRESSORMOTOR RELAIS RELAY COMPRESSOR MOTOR VERZOGERUNGSRELAIS DELAY TIMER MC REINITIALISATION DEFAUT BASSE PRESSION NIEDERDRUCKSCHALTER LOW PRESSURE SWITCH K HOCHDRUCKSCHALTER HIGH PRESSURE SWITCH HP D REINITIALISATION DEFAUT HAUTE PRESSION GEBLASESCHALTER FAN MODE SWITCH S1 LP THERMOSTAT LPHW SELECTEUR DE MODE DU VENTILATEUR PWW-STAT LPHW THERMOSTAT TH THERMOSTAT DE DEGIVRAGE B A HYGROSTAT 3 6 9 HP (300psi) B VEREISUNGSSCHUTZTHERMOSTAT 1 4 7 K3 3 6 1 4 A HYGROSTAT 6 mins 9 7 K2 12V SIDE DEFROST THERMOSTAT B 6(7) LP D HP (400psi) TC A 4 K1 L(L1) REMOTE HUMIDISTAT NTS SCALE D372756 DEHUMIDISTAT MV TC C T DRG No. FT R S IF IN DOUBT ASK SH MC RH VIOLETTE BLANC ROUGE ROSE ORANGE GRIS MARRON BLEU NOIR C1 N(L2) G/Y GREEN/YELLOW GROEN/GELB VERT/JAUNE GREY ORANGE GR BLAU BLUE BRUAN SCHWARZ BLACK BROWN B WIRES NOT CONNECTED (TWIN FAN ASSY ONLY) BR BL TRANSFORMER T L BLK O REMOTE THERMOSTAT UNCONTROLLED WHEN PRINTED BR CAP BRN BR R/B BR P B B BRN COM BUTT BLU BUTT CONNECTOR page13 ISSUE 5 LABEL D380756 DO NOT SCALE PRINT 3 WIRING DIAGRAMS CONT SD139460 ISSUE 21 AIR TEMPERATURE (° C) page14 20 30 40 50 90% 60 80% 1.9 2.4 * = AT 60%RH 0.75 0.85 MAX OPERATING TEMP 40ºC (R22 GAS) MAX OPERATING TEMP 35ºC (R407c GAS) MOISTURE EXTRACTION LITRES/24HOURS 0.55 10 70% 1.2 60% 10°C 50% 0.65 40% ELECTRICAL INPUT kW * 1.5 0 30% SENSIBLE HEAT OUTPUT kW * 20°C 30°C 40°C DH30/30(7)/33/33(7) PERFORMANCE. 4.0 PERFORMANCE GRAPHS SD139460 ISSUE 21 AIR TEMPERATURE (°C) page15 10°C 20°C 30°C 40°C 0 40 40% 60 50% MAX OPERATING TEMP' 40ºC (R22 GAS) MAX OPERATING TEMP' 35ºC (R407c GAS) MOISTURE EXTRACTION LITRES/24HOURS 20 30% 80 60% 100 70% DH50/50(7)/55/55(7)/60/60(7) PERFORMANCE. 120 90% 80% 0.8 1.9 * = AT 60%RH 1.0 1.2 1.4 ELECTRICAL INPUT kW * 2.6 3.5 4.6 OUTPUT kW * SENSIBLE HEAT 4 PERFORMANCE GRAPHS CONT SD139460 ISSUE 21 LITRES PER HOUR page16 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 -5 0 5 90% 10 AIR ON TEMPERATURE DRY BULB °C -10 DH30/33 40% 50% 60% 70% 80% 0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 -5 0 5 10 AIR ON TEMPERATURE DRY BULB °C -10 DH50/55/60 40% 50% 60% 70% 80% 90% 4 PERFORMANCE GRAPHS CONT SD139460 ISSUE 21 RELATIVE HUMIDITY LITRES PER HOUR RELATIVE HUMIDITY 5.0 DIMENSIONS POSITION OF BRACKETS RELATIVE TO WALL 780.00 203.00 436.00 653.00 203.00 30 SERIES WALLHUNG DEHUMIDIFIER 1245.00 242.00 242.00 436.00 653.00 242.00 50 SERIES WALLHUNG DEHUMIDIFIER page17 SD139460 ISSUE 21 830.00 DH30 SERIES PACKED DEHUMIDIFIERS page18 'X' 3120 FRAGILE HANDLE WITH CARE 1295.00 DH50 SERIES MACHINE TYPE DIMENSION X 340.00 5 DIMENSIONS CONT SD139460 ISSUE 21 850.00 page19 172 19 40 38 WATER IN/OUT TUBES DIA 15 250 270 PACKED DIMENSIONS 860.00L x 340.00W x 850.00H IN OUT MOUNTING SLOTS 450 REHEAT SECTION ADDED TO BACK OF M/C AIR IN MAINS IN MAINS IN T.B. AIR OFF 100 15 56 112 CONDENSATE DRAIN COVER FIXINGS IN 2 POSN'S HUMIDISTAT CONTROL KNOB 780 DH30 DIMENSIONS 655 250 3rd ANGLE PROJECTION 5 DIMENSIONS CONT SD139460 ISSUE 21 page20 40 172 19 IN OUT LPHW CONNECTIONS 15mm DIA WHEN FITTED 35 MOUNTING SLOTS PACKED DIMENSIONS 860.00L x 330.00W x 850.00H WATER IN/OUT TUBES DIA 15 510 38.00 REHEAT SECTION ADDED TO BACK OF M/C 25 250 MAINS IN T.B. AIR IN AIR OFF 653 100 56 MAINS IN 15 450 112 780 COVER FIXINGS IN 2 POSN'S DH33 DIMENSIONS CONDENSATE DRAIN HUMIDISTAT CONTROL KNOB 3rd ANGLE PROJECTION 5 DIMENSIONS ONT SD139460 ISSUE 21 250 172 236 AIR IN MAINS IN T.B. AIR OFF 648 HUMIDISTAT CONTROL KNOB WATER IN/OUT TUBES DIA 15mm. PACKED DIMENSIONS 860.00L x 340.00W x 850.00H 19 IN OUT 38 40 MOUNTING SLOTS 450 256 100 page21 15 REHEAT SECTION ADDED TO BACK OF M/C 57 113 782 DH30 WITH METAL COVER CONDENSATE DRAIN MAINS IN COVER FIXINGS IN 2 POSITIONS 3rd ANGLE PROJECTION 5 DIMENSIONS CONT SD139460 ISSUE 21 page22 19 IN OUT 172 AIR IN 250 MAINS IN T.B. AIR OFF 1310.00L x 330.00W x 850.00H PACKED DIMENSIONS DIA 15mm WATER IN/OUT TUBES 40 MOUNTING SLOTS 450.00 38 250 REHEAT SECTION ADDED TO BACK OF M/C 655 15 163 CONDENSATE DRAIN 1245 HUMIDISTAT CONTROL KNOB 50 54 DH50/60 DIMENSIONS COVER FIXINGS IN 3 POSN'S 3rd ANGLE PROJECTION 100 MAINS IN 5 DIMENSIONS CONT SD139460 ISSUE 21 163 50 243 COVER FIXINGS IN 3 POSN'S HUMIDISTAT CONTROL KNOB CONDENSATE DRAIN RH WATER PIPES 1245 AIR IN AIR OFF 57 MAINS IN 100 page23 653 250 MAINS IN T.B. 25 250 WATER IN/OUT TUBES DIA 15. OUT OTHER SIDE IN OUT PACKED DIMENSIONS 1310.00L x 340.00W x 850.00H 450 MOUNTING SLOTS 19 REHEAT SECTION ADDED TO BACK OF M/C 38 LPHW CONNECTIONS 15mm DIA WHEN FITTED 35 510 270 DH55 DIMENSIONS 172 40 3rd ANGLE PROJECTION 5 DIMENSIONS CONT SD139460 ISSUE 21 19 page24 172 236 256 AIR IN PACKED DIMENSIONS 1310.00L x 340.00W x 850.00H WATER IN/OUT TUBES O/D 15mm 40 38 450 MOUNTING SLOT REHEAT SECTION ADDED TO BACK OF M/C AIR OFF 648 236 164 CONDENSATE DRAIN HUMIDISTAT CONTROL KNOB COVER FIXINGS IN 3 POSITIONS 1247 3rd ANGLE PROJECTION 50 55 DH60 ( METAL COVER) 100 15 MAINS IN 5 DIMENSIONS CONT SD139460 ISSUE 21 58 30 6 i 57 14 page25 7 3 5 32 29 31 GAS CHARGE 4 26 2 38 37 36 35 SA64390101 DH30(7)A FRIDGE/ELEC BOX ASSY DH30(7)A 6.0 SPARE PARTS LISTS SD139460 ISSUE 21 ASSY No SA390101 DH30(7)A FRIDGE/ELECT ASSY ITEM NO. PART No. 2 3 4 5 *6 7 14 26 29 30 31 32 35 36 37 38 57 58 5 DESCRIPTION QUAN UNITS EVAP/COND ASSY DH30A COMPRESSOR ASSEMBLY AE5470C 230V 50HZ FAN CENTRIFUGAL 1050RPM ELECT BOX ASSY DH30A & ARH DRIP TRAY (EVAPORATOR) DRIP TRAY (COMPRESSOR) SCHRADER VALVE U TYPE NUT SWITCH HIGH PRESSURE ACB-DB64 OWNERS INSTALLATION MANUAL REFRIGERANT R407c LP SWITCH LCB-DA15 EVAPORATOR CONDENSER DRIER HRP 274151 CAPILLARY TUBE WALL BRACKET ANTI VIBRATION BUFFER WIER KIT (OPTIONAL) 1 1 1 1 1 1 1 2 1 1 0.5 1 1 1 1 0.864 1 2 1 off off off off off off off off off off kg off off off off m off off off VARIATION WHEN HUMIDISTAT OPTION FITTED AS ABOVE BUT DROP SA144501 ELECT BOX ASSY DH30A & ARH 1 off AND FIT SA144509 1 off 1 off SD140453 SA144154 SD101450 SA144501 SD139050 SD146951 SD066350 SD144250 SD266450 SD139451 SP182554 SD266550 SD138052 SD136950 SD141250 SD318250 SD138851 D458450 SD229503 ELECT BOX ASSY DH30A + REMOTE STAT * FOR MURPROTEC VERSIONS FIT SD139051 DRIP TRAY (EVAPORATOR) page26 SD139460 ISSUE 21 page27 SD139460 ISSUE 21 58 57 30 i 6 14 7 3 35 5 2 36 37 38 39 31 GAS CHARGE 34 26 4 28 29 SA64400802 FRIDGE/ELEC ASSY DH30AX ASSY No SA400802 DH30(7)AX FRIDGE ELECT ASSY ITEM NO. PART No. 2 3 4 5 *6 7 14 26 28 29 30 31 34 35 36 37 38 39 57 58 5 DESCRIPTION QUAN UNITS EVAP/COND ASSY R407C COMPRESSOR ASSY AE5470C 1PH N 230V 50HZ FAN CENTRIFUGAL 1050RPM ELECT BOX ASSY DH33AX DRIPTRAY DH30/DH33 DRIP TRAY (COMPRESSOR) SCHRADER VALVE U TYPE NUT SOLENOID VALVE SOLENOID COIL 240V OWNER INSTALLATION MANUAL REFRIGERANT R407c SWITCH HIGH PRESSURE ACB-DB64 LP SWITCH LCB-DA15 EVAPORATOR CONDENSER DRIER HRP 274151 CAPILLARY TUBE WALL BRACKET ANI VIBRATION BUFFER WIER KIT (OPTIONAL) 1 1 1 1 1 1 1 2 1 1 1 0.5 1 1 1 1 1 0.864 1 2 1 off off off off off off off off off off off kg off off off off off m off off off VARIATION WHEN HUMIDISTAT OPTION FITTED AS ABOVE BUT DROP SA144502 ELECT BOX ASSY DH30AX 1 off AND FIT SA144510 1 off 1 off SD140454 SA144154 SD101450 SD144502 SD139050 SD146951 SD066350 SD144250 SD146150 SD146250 SD139451 SP182554 SD266450 SD266550 SD138051 SD136950 SD141250 SD318250 SD138851 D458450 SD229503 ELECT BOX ASSY DH30AX + REMOTE STAT * FOR MURPROTEC VERSIONS FIT SD139051 DRIP TRAY (EVAPORATOR) page28 SD139460 ISSUE 21 30 31 30 40 i 57 6 14 7 3 28 5 35 36 46 GAS CHARGE 2 4 26 29 2 39 38 53 TEV PHIAL 52 14 0. 00 SA64239207 FRIDGE/ELEC ASSY DH30ARH 15.00 15.00 page29 SD139460 ISSUE 21 ASSY No SA239207 DH30ARH FRIDGE/ELECT ASSY ITEM NO. PART No. 2 3 4 5 6 7 14 26 28 29 30 31 35 36 38 39 40 46 52 53 57 5 QUAN UNITS 1 1 1 1 1 1 1 2 1 1 2 1 1 1 1 1 1 1.04 1 1 1 1 off off off off off off off off off off off off off off off off off kg off off off off VARIATION WHEN HUMIDISTAT OPTION FITTED AS ABOVE BUT DROP SA144501 ELECT BOX ASSY DH30A & ARH 1 off AND FIT SA144509 1 off 1 off SA140452 SA144154 SD101450 SA144501 SD139050 SD146951 SD066350 SD144250 SD155750 SD155751 SD155850 SD172650 SD266450 SD266550 SD138050 SD136050 SD139451 SP182554 SD141250 SD086752 SD152650 SD229503 DESCRIPTION EVAP COND ASSY DH30ARH COMPRESSOR ASSY AE5470C 1PH N 230V 50HZ FAN CENTRIFUGAL 1050RPM ELECT BOX ASSY DH30A & ARH DRIP TRAY (EVAPORATOR) DRIP TRAY (COMPRESSOR) SCHRADER VALVE U TYPE NUT BRACKET WATER COIL BRACKET WATER COIL BRACKET WATER COIL CONDENSER CO-AXIAL SERPENTINE SWITCH HIGH PRESSURE ACB-DB64 LP SWITCH LCB-DA15 EVAPORATOR CONDENSER OWNER INSTALLATION MANUAL REFRIGERANT R407c DRIER HRP 274151 TEV 0.5INE-GA-BP10 WALL BRACKET WIER KIT ELECT BOX ASSY DH30A + REMOTE STAT * FOR MURPROTEC VERSIONS FIT SD139051 DRIP TRAY (EVAPORATOR) page30 SD139460 ISSUE 21 page31 SD139460 ISSUE 21 58 57 30 i 6 14 7 3 29 5 31 GAS CHARGE AT 130 PSI-G 32 62 61 63 60 4 26 2 2 39 38 37 36 SA390103 FRIDGE/ELEC ASSY DH30AP ASSY No SA390103 DH30(7)AP FRIDGE/ELECT ASSY ITEM NO. PART No. 2 3 4 5 *6 7 14 26 29 30 31 32 36 37 38 39 57 58 60 61 62 63 SD140453 SA144154 SD101450 SA144507 SD139050 SD146951 SD066350 SD144250 SD062553 SD139451 SP182554 SD266550 SD138052 SD136050 SD141250 SD318250 SD138851 D458450 SD362850 SD362950 SD103251 SD103252 SD229503 DESCRIPTION QUAN UNITS EVAP/COND ASSY DH30A COMPRESSOR ASSY AE5470C 1PH N 230V 50HZ FAN CENTRIFUGAL 1050RPM ELECT BOX ASSY DH30AP DRIPTRAY (EVAPORATOR) DRIP TRAY (COMPRESSOR) SCHRADER VALVE U TYPE NUT HP SWITCH 400PSI OWNER INSTALLATION MANUAL REFRIGERANT R407c LP SWITCH LCB-DA15 EVAPORATOR CONDENSER DRIER HRP 274151 CAPILLARY TUBE 0.052 I/D WALL BRACKET ANTI VIBRATION BUFFER AIR HEATER ELEMENT HEATER COVER THERMAL CUTOUT AUTO RESET THERMAL CUTOUT MANUAL RESET WEIR KIT (OPTIONAL) 1 1 1 1 1 1 1 2 1 1 0.5 1 1 1 1 0.864 1 2 1 1 1 1 1 off off off off off off off off off off kg off off off off m off off off off off off off 1 off * FOR MURPROTEC VERSIONS FIT SD139051 DRIP TRAY (EVAPORATOR) page32 SD139460 ISSUE 21 page33 SD139460 ISSUE 21 58 57 30 i 6 14 7 3 5 34 27 33 GAS CHARGE 4 2 26 39 38 37 36 2 31 SA64390102 FRIDGE/ELEC ASSY DH33A ASSY No SA390102 DH33(7)A FRIDGE/ELECT ASSY ITEM NO. PART No. DESCRIPTION QUAN UNITS EVAP/COND ASSY DH33(7)A COMPRESSOR ASSY AE5470C 1PH N 230V 50HZ FAN CENTRIFUGAL 1050RPM ELECT BOX ASSY DH30A & ARH DRIPTRAY DH30/DH33 DRIP TRAY (COMPRESSOR) SCHRADER VALVE U TYPE NUT SWITCH HIGH PRESSURE ACB-DB64 OWNER INSTALLATION MANUAL BLANKING PLATE DH33 REFRIGERANT R407c LP SWITCH LCB-DA15 EVAPORATOR CONDENSER DRIER HRP 274151 CAPILLARY TUBE 0.052 I/D WALL BRACKET ANTI VIBRATION BUFFER 1 1 1 1 1 1 1 2 1 1 1 0.5 1 1 1 1 0.813 1 2 off off off off off off off off off off off kg off off off off m off off 2 3 4 5 6 7 14 26 27 30 31 33 34 36 37 38 39 57 58 SD140407 SA144154 SD101450 SA144501 SD139050 SD146951 SD066350 SD144250 SD266450 SD139451 SD264550 SP182554 SD266550 SD138052 SD136951 SD141250 SD318250 SD138851 D458450 5 VARIATION WHEN HUMIDISTAT OPTION FITTED AS ABOVE BUT DROP SA144501 ELECT BOX ASSY DH30A & ARH 1 off AND FIT SA144509 1 off 1 off ELECT BOX ASSY DH30A + REMOTE STAT * FOR MURPROTEC VERSIONS FIT SD139051 DRIP TRAY (EVAPORATOR) page34 SD139460 ISSUE 21 page35 SD139460 ISSUE 21 58 57 30 i 6 14 7 3 40 5 27 39 GAS CHARGE 4 26 2 38 37 36 35 2 33 34 SA64400801 31 FRIDGE/ELEC ASSY DH33AX ASSY No SA400801 DH33(7)AX FRIDGE/ELECT ASSY ITEM NO. PART No. DESCRIPTION QUAN UNITS EVAP/COND ASSY DH33(7)AX COMPRESSOR ASSY AE5470C 1PH N 230V 50HZ FAN CENTRIFUGAL 1050RPM ELECT BOX ASSY DH33AX DRIP TRAY (EVAPORATOR) DRIP TRAY (COMPRESSOR) SCHRADER VALVE U TYPE NUT SWITCH HIGH PRESSURE ACB-DB64 OWNER INSTALLATION MANUAL BLANKING PLATE SOLENOID VALVE SOLENOID COIL 240V EVAPORATOR CONDENSER DRIER HRP 274151 CAPILLARY TUBE 0.052 I/D REFRIGERANT R407c LP SWITCH LCB-DA15 WALL BRACKET ANTI VIBRATION BUFFER 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 0.864 0.5 1 1 2 off off off off off off off off off off off off off off off off m kg off off off 2 3 4 5 *6 7 14 26 27 30 31 33 34 35 36 37 38 39 40 57 58 SD140408 SA144154 SD101450 SA144502 SD139050 SD146951 SD066350 SD144250 SD266450 SD139451 SD264550 SD146150 SD146250 SD138051 SD136051 SD141250 SD318250 SP182554 SD266550 SD138851 D458450 5 VARIATION WHEN HUMIDISTAT OPTION FITTED AS ABOVE BUT DROP SA144502 ELECT BOX ASSY DH30AX 1 off AND FIT SA144510 1 off 1 off ELECT BOX ASSY DH30AX + REMOTE STAT * FOR MURPROTEC VERSIONS FIT SD139051 DRIP TRAY (EVAPORATOR) page36 SD139460 ISSUE 21 35 38 35 30 57 i 6 14 7 3 36 46 5 27 45 GAS CHARGE 2 4 26 37 41 40 2 53 TEV PHIAL 52 14 0. 00 31 SA64239216 FRIDGE/ELEC ASSY DH33ARH 15.00 15.00 page37 SD139460 ISSUE 21 ASSY No SA239216 DH33ARH FRIDGE/ELECT ASSY ITEM NO. PART No. DESCRIPTION EVAP/COND ASSY DH33ARH COMPRESSOR ASSY AE5470C 1PH N 230V 50HZ FAN CENTRIFUGAL 1050RPM ELECT BOX ASSY DH30A & ARH DRIP TRAY (EVAPORATOR) DRIP TRAY (COMPRESSOR) SCHRADER VALVE U TYPE NUT SWITCH HIGH PRESSURE ACB-DB64 OWNER INSTALLATION MANUAL BLANKING PLATE BRACKET WATER COIL BRACKET WATER COIL BRACKET WATER COIL CONDENSER CO-AXIAL SERPENTINE EVAPORATOR CONDENSER REFRIGERANT R407c LP SWITCH LCB-DA15 DRIER HRP 274151 TEV 0.5INE-GA-BP10 WALL BRACKET QUAN UNITS 1 1 1 1 1 1 1 2 1 1 1 2 1 1 1 1 1 1.04 1 1 1 1 off off off off off off off off off off off off off off off off off kg off off off off 2 3 4 5 6 7 14 26 27 30 31 35 36 37 38 40 41 45 46 52 53 57 SD140406 SA144154 SD101450 SA144501 SD139050 SD146951 SD066350 SD144250 SD266450 SD139451 SD264550 SD155850 SD155750 SD155751 SD172650 SD138050 SD136051 SP182554 SD266550 SD141250 SD086752 SD156250 5 VARIATION WHEN HUMIDISTAT OPTION FITTED AS ABOVE BUT DROP SA144501 ELECT BOX ASSY DH30A & ARH 1 off AND FIT SA144509 1 off 1 off ELECT BOX ASSY DH30A + REMOTE STAT * FOR MURPROTEC VERSIONS FIT SD139051 DRIP TRAY (EVAPORATOR) page38 SD139460 ISSUE 21 page39 SD139460 ISSUE 21 57 A1 5 2 A2 35 36 37 38 33 GAS CHARGE AT 130 PS1-G 32 34 8 15 4 30 SA64390201 6 i 58 FRIDGE/ELEC ASSY DH50/60A/ DH60(7)A 7 ASSY No SA390201 DH50(7)/60(7) FRIDGE/ELECT ASSY ITEM NO. PART No. DESCRIPTION EVAP/COND ASSY DH50A COMPRESSOR HERM AJ5512C FAN ASSY DRIP TRAY (EVAPORATOR) ELECT BOX ASSY DH55A DRIP TRAY (COMPRESSOR) SCHRADER VALVE OWNER INSTALLATION MANUAL SWITCH HIGH PRESSURE ACB-DB64 REFRIGERANT R407c LP SWITCH LCB-DA15 EVAPORATOR CONDENSER DRIER HRP 274151 CAPILLARY TUBE 0.052 I/D WALL BRACKET ANTI VIBRATION BUFFER QUAN UNITS 1 1 1 1 1 1 1 1 1 0.75 1 1 1 1 2 X 0.94 1 2 off off off off off off off off off kg off off off off m off off 2 4 5 *6 7 8 15 30 32 33 34 35 36 37 38 57 58 SD140753 SD132653 SD378201 SD140950 SA144801 SD146850 SD066350 SD139451 SD266450 SP182554 SD266550 SD139152 SD137850 SD141250 SD318250 SD141751 D458450 7 VARIATION WHEN HUMIDISTAT OPTION FITTED AS ABOVE BUT DROP SA144801 ELECT BOX ASSY DH55A 1 off AND FIT SA144811 1 off 1 off ELECT BOX ASSY DH55A + REMOTE STAT * FOR MURPROTEC VERSIONS FIT SD140951 DRIP TRAY (EVAPORATOR) page40 SD139460 ISSUE 21 page41 SD139460 ISSUE 21 32 33 57 A1 5 65 2 31 GAS CHARGE AT 130 PSI-G 40 41 42 A2 43 37 38 8 15 4 6 30 SA64401102 i 58 7 FRIDGE/ELEC ASSY DH50/60AX ASSY No SA401102 DH50(7)/60(7)AX FRIDGE/ELECT ASSY ITEM NO. PART No. DESCRIPTION EVAP COND ASSY DH50AX COMPRESSOR HERM AJ5512C FAN ASSY DRIP TRAY (EVAPORATOR) ELECT BOX ASSY DH55AX DRIP TRAY (COMPRESSOR) SCHRADER VALVE OWNER INSTALLATION MANUAL REFRIGERANT R407c SOLENOID VALVE SOLENOID COIL 240V SWITCH HIGH PRESSURE ACB-DB64 LP SWITCH LCB-DA15 EVAPORATOR CONDENSER DRIER HRP274151 CAPILLARY TUBE 0.052 I/D WALL BRACKET ANTI VIBRATION BUFFER QUAN UNITS 1 1 1 1 1 1 1 1 0.8 1 1 1 1 1 1 1 2 X 1.118 1 2 off off off off off off off off kg off off off off off off off m off off 2 4 5 *6 7 8 15 30 31 32 33 37 38 40 41 42 43 57 58 SD140754 SD132653 SD378201 SD140950 SA144802 SD146850 SD066350 SD139451 SP182554 SD146150 SD146250 SD266450 SD266550 SD139151 SD137850 SD141250 SD318250 SD141751 D458450 7 VARIATION WHEN HUMIDISTAT OPTION FITTED AS ABOVE BUT DROP SA144802 ELECT BOX ASSY DH55AX 1 off AND FIT SA144812 1 off 1 off ELECT BOX ASSY DH55AX + REMOTE STAT * FOR MURPROTEC VERSIONS FIT SD140951 DRIP TRAY (EVAPORATOR) page42 SD139460 ISSUE 21 56 30 15.00 15.00 page43 SD139460 ISSUE 21 i TEV PHIAL 55 57 37 A1 5 2 31 GAS CHARGE AT 130 PS1-G 44 45 43 62 38 8 15 6 4 SA64252207 FRIDGE/ELEC ASSY DH50/60ARH 39 7 40 39 ASSY No SA252207 DH50/60ARH FRIDGE/ELECT ASSY ITEM NO. PART No. DESCRIPTION EVAP/COND ASSY DH50ARH COMPRESSOR HERM AJ5512C FAN ASSY DRIP TRAY (EVAPORATOR) ELECT BOX ASSY DH55A DRIP TRAY (COMPRESSOR) SCHRADER VALVE OWNER INSTALLATION MANUAL REFRIGERANT R407c BRACKET WATER COIL BRACKET WATER COIL BRACKET CONDENSER CO-AXIAL SERPENTINE SWITCH HIGH PRESSURE ACB-DB64 EVAPORATOR CONDENSER EXPANSION VALVE INE-1.5GA DRIER HRP 274151 WALL BRACKET (RH) LP SWITCH LCB-DA15 QUAN UNITS 1 1 1 1 1 1 1 1 1.64 1 1 2 1 1 1 1 1 1 1 1 off off off off off off off off kg off off off off off off off off off off off 2 4 5 6 7 8 15 30 31 37 38 39 40 43 44 45 55 56 57 62 SA140752 SD132653 SD378201 SD140950 SA144801 SD146850 SD066350 SD139451 SP182554 SD155750 SD155751 SD155650 SD168150 SD266450 SD139150 SD137850 SD086751 SD141250 SD156050 SD266550 7 VARIATION WHEN HUMIDISTAT OPTION FITTED AS ABOVE BUT DROP SA144801 ELECT BOX ASSY DH55A 1 off AND FIT SA144811 1 off ELECT BOX ASSY DH55A + REMOTE STAT * FOR MURPROTEC VERSIONS FIT page44 SD139460 ISSUE 21 page45 SD139460 ISSUE 21 57 A1 70 5 72 73 33 70 72 GAS CHARGE 71 73 2 71 40 41 42 43 ,00 100 34 8 15 32 4 6 SA390203 30 i 58 7 FRIDGE/ELEC ASSY DH50/60AP ASSY No SA390203 DH50(70/60(7)AP FRIDGE/ELECT ASSY ITEM NO. PART No. 2 4 5 *6 7 8 15 30 32 33 34 40 41 42 43 57 58 70 71 72 73 SD140753 SD132653 SD378201 SD140950 SA144808 SD146850 SD066350 SD139451 SD062553 SP182554 SD266550 SD139152 SD137850 SD131250 SD318250 SD141751 D458450 SD362950 SD362850 SD103251 SD103252 SD229504 DESCRIPTION EVAP/COND ASSY DH50A COMPRESSOR HERM AJ5512C FAN ASSY DRIP TRAY (EVAPORATOR) ELECT BOX ASSY DH50AP DRIP TRAY (COMPRESSSOR) SCHRADER VALVE OWNER INSTALLATION MANUAL HP SWITCH 400PSI REFRIGERANT R407c LP SWITCH LCB-DA15 EVAPORATOR CONDENSER DRIER HRP 274151 CAPILLARY TUBE 0.052 I/D WALL BRACKET ANTI VIBRATION BUFFER HEATER COVER AIR HEATER ELEMENT THERMAL CUTOUT AUTO RESET THERMAL CUTOUT MANUAL RESET WEIR KIT (OPTIONAL) QUAN UNITS 1 1 1 1 1 1 1 1 1 0.75 1 1 1 1 2 X 0.94 1 2 2 2 2 2 1 off off off off off off off off off kg off off off off m off off off off off off off 1 off * FOR MURPROTEC VERSIONS FIT SD140951 DRIP TRAY (EVAPORATOR) page46 SD139460 ISSUE 21 page47 SD139460 ISSUE 21 51 28 i 48 57 39 41 5 2 40 39 40 27 31 8 14 29 47 4 30 (COMPRESSOR) BLUE SEAL (HEATERS) PINK SEAL GAS CHARGE AT 130 PSI-G HP SWITCH --- 400 psi HP SWITCH ---300 psi SA390204 FRIDGE/ELECT ASSY DH60AHP (134a) 6 58 7 ASSY No SA390204 DH60AHP FRIDGE/ELECT ASSY ITEM NO. PART No. 2 4 5 *6 7 8 14 28 29 30 31 39 40 41 47 48 51 57 58 SA140752 SD132653 SD378202 SD140950 SD144810 SD146850 SD066350 SD139451 SD062553 SP182555 SD266550 SD362950 SD362850 SD103252 SA062554 SD447350 SD141250 SD141751 D458450 DESCRIPTION EVAP/COND ASSY DH50ARH COMPRESSOR HERM AJ5512C FAN ASSY DRIP TRAY ELECT BOX ASSY DH60AHP DRIP TRAY PLASTIC BLACK ABS SCHRADER VALVE OWNER INSTALLATION MANUAL HP SWITCH 400PSI REFRIGERANT R134a LP SWITCH LCB-DA15 HEATER COVER AIR HEATER ELEMENT THERMAL CUTOUT MANUAL RESET HP SWITCH 300PSI TEV EBF JE A CP60 DRIER HRP 274151 WALL BRACKET ANTI VIBRATION BUFFER QUAN UNITS 1 1 1 1 1 1 1 1 1 0.8 1 2 2 2 1 1 1 1 2 off off off off off off off off off kg off off off off off off off off off 1 off * FOR MURPROTEC VERSIONS FIT SD140951 DRIP TRAY (EVAPORATOR) page48 SD139460 ISSUE 21 page49 SD139460 ISSUE 21 5 57 2 46 47 48 49 2 OFF 100.00 8 15 32 45 33 6 4 30 i GAS CHARGE AT 130 PSI-G SA64390202 FRIDGE/ELEC ASSY DH55A 7 58 51 ASSY No SA390202 DH55(7)A FRIDGE/ELECT ASSY ITEM NO. PART No. DESCRIPTION EVAP COND ASSY (R407C) DH55A COMPRESSOR HERM AJ5512C FAN ASSY DRIP TRAY (EVAPORATOR) ELECT BOX ASSY DH55A DRIP TRAY (COMPRESSOR) SCHRADER VALVE OWNER INSTALLATION MANUAL SWITCH HIGH PRESSURE ACB-DB64 REFRIGERANT R407c LP SWITCH LCB-DA15 EVAPORATOR CONDENSER DRIER HRP 274151 CAPILLARY TUBE 0.052I/D BLANKING PLATE DH33 WALL BRACKET ANTI VIBRATION BUFFER QUAN UNITS 1 1 1 1 1 1 1 1 1 0.76 2 1 1 1 2 X 0.889 1 1 2 off off off off off off off off off kg off off off off m off off off 2 4 5 6 7 8 15 30 32 33 45 46 47 48 49 51 57 58 SD140707 SD132653 SD378201 SD140950 SA144801 SD146850 SD066350 SD139451 SD266450 SP182554 SD266550 SD139152 SD137851 SD141250 SD318250 SD264551 SD141751 D458450 7 VARIATION WHEN HUMIDISTAT OPTION FITTED AS ABOVE BUT DROP SA144801 ELECT BOX ASSY DH55A 1 off AND FIT SA144811 1 off 1 off ELECT BOX ASSY DH55A + REMOTE STAT * FOR MURPROTEC VERSIONS FIT SD140951 DRIP TRAY (EVAPORATOR) page50 SD139460 ISSUE 21 page51 SD139460 ISSUE 21 30 i 5 6 36 37 57 2 32 2 off 45 40 41 42 43 100.00 8 15 38 51 58 7 4 GAS CHARGE AT 130 PSI-G SA64401101 FRIDGE/ELEC ASSY DH55AX ASSY No SA401101 DH55(7)AX FRIDGE/ELECT ASSY ITEM NO. PART No. DESCRIPTION EVAP/COND ASSY DH55AX COMPRESSOR HERM AJ5512C FAN ASSY DRIP TRAY (EVAPORATOR) ELECT BOX ASSY DH55AX DRIP TRAY (COMPRESSOR) SCHRADER VALVE OWNER INSTALLATION MANUAL SWITCH HIGH PRESSURE ACB-DB64 SOLENOID VALVE COIL 240V REFRIGERANT R407c EVAPORATOR CONDENSER DRIER HRP 274151 CAPILLARY TUBE 0.052 I/D LP SWITCH LCB-DA15 BLANKING PLATE DH50 WALL BRACKET ANTI VIBRATION BUFFER QUAN UNITS 1 1 1 1 1 1 1 1 1 1 1 0.76 1 1 1 2 X 1.118 2 1 1 2 off off off off off off off off off off off kg off off off m off off off off 2 4 5 6 7 8 15 30 32 36 37 38 40 41 42 43 45 51 57 58 SD140708 SD132653 SD378201 SD140950 SA144802 SD146850 SD066350 SD139451 SD266450 SD146150 SD146250 SP182554 SD139151 SD137851 SD141250 SD318250 SD266550 SD264551 SD141751 D458450 7 VARIATION WHEN HUMIDISTAT OPTION FITTED AS ABOVE BUT DROP SA144802 ELECT BOX ASSY DH55AX 1 off AND FIT SA144812 1 off 1 off ELECT BOX ASSY DH55AX + REMOTE STAT * FOR MURPROTEC VERSIONS FIT SD140951 DRIP TRAY (EVAPORATOR) page52 SD139460 ISSUE 21 56 30 15.00 15.00 page53 SD139460 ISSUE 21 i 55 12 TEV PHIAL 57 37 5 A1 2 A 47 48 8 15 43 45 38 4 51 31 GAS CHARGE AT 130 PSI-G SA64252216 FRIDGE/ELEC ASSY DH55ARH 39 7 40 39 ASSY No SA252216 DH55ARH FRIDGE/ELECT ASSY ITEM NO. PART No. DESCRIPTION EVAP/COND ASSY DH55ARH COMPRESSOR HERM AJ5512C FAN ASSY DRIP TRAY (EVAPORATOR) ELECT BOX ASSY DH55A DRIP TRAY (COMPRESSOR) SCHRADER VALVE OWNER INSTALLATION MANUAL REFRIGERANT R407c BRACKET WATER COIL BRACKET WATER COIL BRACKET CONDENSER CO-AXIAL SERPENTINE SWITCH HIGH PRESSURE ACB-DB64 LP SWITCH LCB-DA15 BLANKING PLATE DH50 EXPANSION VALVE INE-1.5GA DRIER HRP 274151 WALL BRACKET DH50(RH) QUAN UNITS 1 1 1 1 1 1 1 1 1.64 1 1 2 1 1 1 1 1 1 1 off off off off off off off off kg off off off off off off off off off off 2 4 5 *6 7 8 15 30 31 37 38 39 40 43 45 51 55 56 57 SA140706 SD132653 SD378201 SD140950 SA144801 SD146850 SD066350 SD139451 SP182554 SD155750 SD155751 SD155650 SD168150 SD266450 SD266550 SD264551 SD086751 SD141250 SD156050 7 VARIATION WHEN HUMIDISTAT OPTION FITTED AS ABOVE BUT DROP SA144801 ELECT BOX ASSY DH55A 1 off AND FIT SA144811 1 off 1 off ELECT BOX ASSY DH55A + REMOTE STAT * FOR MURPROTEC VERSIONS FIT SD140951 DRIP TRAY (EVAPORATOR) page54 SD139460 ISSUE 21 page55 SD139460 ISSUE 21 6 11 4 14 13 8 2 7 0.3 5 MINUTES 10 10 5 TIMER MAKE ON DELAY 9 SA144501-10 15 16 12 THESE 2 ITEMS USED ON VERSIONS WITH REMOTE HUMIDISTAT OR RESISTANCE HEATERS ELEC BOX ASSY DH30/30(7)/33/33(7) RANGE ELEC BOX ASSY DH30/30(7)/33/33(7)A-ARH SA144501 2 SD041450 CONTROL KNOB 1.000 4 SD349350 GASKET 1.000 5 SD062350 HUMIDISTAT 1.000 6 SD118351 DEFROST STAT 1.000 7 SD106550 FAN CAP 2µF 1.000 8 SD219250 RELAY C/O 2 POLE 25A 230V AC COIL 1.000 9 SD089550 TIMER 1.000 10 SD038750 RUN CAP 15µF 1.000 11 SD072851 3 WAY TERM' BLOCK 1.000 12 SA145901 LOOM ASSY 1.000 13 SD188950 ROCKER SWITCH 1.000 14 D211050 COVER 1.000 ELEC BOX ASSY DH30/30(7)/33/33(7)A-ARH WITH REMOTE HUMIDISTAT SA144509 2 SD041450 CONTROL KNOB 1.000 4 SD349350 GASKET 1.000 5 SD062350 HUMIDISTAT 1.000 6 SD118351 DEFROST STAT 1.000 7 SD106550 FAN CAP 2µF 1.000 8 SD219250 RELAY C/O 2 POLE 25A 230V AC COIL 1.000 9 SD089550 TIMER 1.000 10 SD038750 RUN CAP 15µF 1.000 11 SD072853 5 WAY TERMINAL BLOCK 15A 1.000 12 SA145903 LOOM ASSY 1.000 13 SD188950 ROCKER SWITCH 1.000 14 D211050 COVER 1.000 15 SD336550 TRANSFORMER 12V 1.000 16 SD378350 RELAY 25A C/O 12V 1.000 page56 SD139460 ISSUE 21 ELEC BOX ASSY DH30/30(7)/33/33(7)AX SA144502 2 SD041450 CONTROL KNOB 1.000 4 SD349350 GASKET 1.000 5 SD062350 HUMIDISTAT 1.000 6 SA145803 TIMER DEFROST STAT 1.000 7 SD106550 FAN CAP 2µF 1.000 8 SD219250 RELAY C/O 2 POLE 25A 230V AC COIL 1.000 9 SD089550 TIMER 1.000 10 SD038750 RUN CAP 15µF 1.000 11 SD072851 3 WAY TERM' BLOCK 1.000 12 SA146401 LOOM ASSY 1.000 13 SD188950 ROCKER SWITCH 1.000 14 D211050 COVER 1.000 ELEC BOX ASSY DH30/30(7)/33/33(7)AX WITH REMOTE HUMIDISTAT SA144510 2 SD041450 CONTROL KNOB 1.000 4 SD349350 GASKET 1.000 5 SD062350 HUMIDISTAT 1.000 6 SA145803 TIMER DEFROST STAT 1.000 7 SD106550 FAN CAP 2µF 1.000 8 SD219250 RELAY C/O 2 POLE 25A 230V AC COIL 1.000 9 SD089550 TIMER 1.000 10 SD038750 RUN CAP 15µF 1.000 11 SD072653 5 WAY TERM' BLOCK 15A 1.000 12 SA146403 LOOM ASSY 1.000 13 SD188950 ROCKER SWITCH 1.000 14 D211050 COVER 1.000 15 SD336550 TRANSFORMER 12V 1.000 16 SD378350 RELAY 25A C/O 12V 1.000 page57 SD139460 ISSUE 21 ELEC BOX ASSY DH30/30(7)AP SA144507 2 SD041450 CONTROL KNOB 1.000 4 SD349350 GASKET 1.000 5 SD062350 HUMIDISTAT 1.000 6 SD118351 DEFROST STAT 1.000 7 SD106550 FAN CAP 2µF 1.000 8 SD219250 RELAY C/O 2 POLE 25A 230vac COIL 1.000 9 SD089550 TIMER 1.000 10 SD038750 RUN CAP 15µF 1.000 11 SD072650 6 WAY TERM' BLOCK 1.000 12 SA145902 LOOM ASSY 1.000 13 SD188950 ROCKER SWITCH 1.000 14 D211050 COVER 1.000 15 SA336550 TRANSFORMER 12v 1.000 16 SD378350 RELAY C/O 25A 12v COIL 1.000 ELEC BOX ASSY DH30/30(7)AXP SA144508 2 SD041450 CONTROL KNOB 1.000 4 SD349350 GASKET 1.000 5 SD062350 HUMIDISTAT 1.000 6 SA145803 TIMER DEFROST STAT 1.000 7 SD106550 FAN CAP 2µF 1.000 8 SD219250 RELAY C/O 2 POLE 25A 230vac COIL 1.000 9 SD089550 TIMER 1.000 10 SD038750 RUN CAP 15µF 1.000 11 SD072650 6 WAY TERM' BLOCK 1.000 12 SA146402 LOOM ASSY 1.000 13 SD188950 ROCKER SWITCH 1.000 14 D211050 COVER 1.000 15 SA336550 TRANSFORMER 12v 1.000 16 SD378350 RELAY C/O 25A 12v COIL 1.000 page58 SD139460 ISSUE 21 page59 SD139460 ISSUE 21 3 5 9 12 10 15 16 THESE 2 ITEMS USED ON VERSIONS VERSIONS WITH RESISTANCE HEATERS OR REMOTE HUMIDISTATS 1 7 6 VERSION ONLY FITTED ON 'AX' 14 FITTED ON 'A' / 'ARH' VERSIONS ONLY 13 4 17 SA64144801 TO 09,11 AND 12 8 ELEC BOX ASSY DH50/50(7)/55/55(7)/60/60(7) RANGE ELEC BOX ASSY DH50/50(7)/55/55(7)/60/60(7)A-ARH SA144801 1 SD139750 ELECTRICS BOX 1.000 3 SD041450 CONTROL KNOB 1.000 4 SD349351 GASKET 1.000 5 SD062350 HUMIDISTAT 1.000 6 SD118351 DEFROST STAT 1.000 7 SD022150 FAN CAP 6µF 1.000 8 SD092151 RELAY 1.000 9 SD089550 TIMER 1.000 10 SD038750 RUN CAP 15µF ( R407c version) 1.000 11 SD072851 3 WAY TERM' BLOCK 1.000 12 SA146001 LOOM ASSY 1.000 13 SD188950 ROCKER SWITCH 1.000 17 SD219350 COVER 1.000 ELEC BOX ASSY DH50/50(7)/55/55(7)/60/60(7)A-ARH WITH REMOTE HUMIDISTAT SA144811 1 SD139750 ELECTRICS BOX 1.000 3 4 SD041450 CONTROL KNOB 1.000 SD349351 GASKET 1.000 5 SD062350 HUMIDISTAT 1.000 6 SD118351 DEFROST STAT 1.000 7 SD022150 FAN CAP 6µF 1.000 8 SD092151 RELAY 1.000 9 SD089550 TIMER 1.000 10 SD038750 RUN CAP 15µF 1.000 11 SD072853 5 WAY TERM' BLOCK 1.000 12 SA146002 LOOM ASSY 1.000 13 SD188950 ROCKER SWITCH 1.000 15 SD336550 TRANSFORMER 12V 1.000 16 SD378350 RELAY 25A C/O 12V 1.000 17 SD219350 COVER 1.000 page60 SD139460 ISSUE 21 ELEC BOX ASSY DH50/50(7)/55/55(7)/60/60(7)AX SA144802 1 SD139750 ELECTRICS BOX 1.000 3 SD041450 CONTROL KNOB 1.000 4 SD349351 GASKET 1.000 5 SD062350 HUMIDISTAT 1.000 7 SD022150 FAN CAP 6µF 1.000 8 SD092151 RELAY 1.000 9 SD089550 TIMER 1.000 10 SD038750 RUN CAP 15µF 1.000 11 SD072851 3 WAY TERM' BLOCK 1.000 12 SA146501 LOOM ASSY 1.000 13 SD188950 ROCKER SWITCH 1.000 14 SD145803 TIMER / DEFROST STAT 1.000 17 D219350 COVER 1.000 ELEC BOX ASSY DH50/50(7)/55/55(7)/60/60(7)AX WITH REMOTE HUMIDISTAT SA144812 1 SD139750 ELECTRICS BOX 1.000 3 SD041450 CONTROL KNOB 1.000 4 SD349351 GASKET 1.000 5 SD062350 HUMIDISTAT 1.000 7 SD022150 FAN CAP 6µF 1.000 8 SD64092151 RELAY 1.000 9 SD089550 TIMER 1.000 10 SD038750 RUN CAP 15µF 1.000 11 SD072851 3 WAY TERM' BLOCK 1.000 12 SA146503 LOOM ASSY 1.000 13 SD188950 ROCKER SWITCH 1.000 14 SD145803 TIMER / DEFROST STAT 1.000 15 SD336550 TRANSFORMER 12V 1.000 16 SD378350 RELAY 25A C/O 12V 1.000 17 D219350 COVER 1.000 page61 SD139460 ISSUE 21 ELEC BOX ASSY DH50/50(7)/60/60(7)AP SA144808 1 SD139750 ELECTRICS BOX 1.000 3 SD041450 CONTROL KNOB 1.000 4 SD349351 GASKET 1.000 5 SD062350 HUMIDISTAT 1.000 6 SD118351 DEFROST STAT 1.000 7 SD022150 FAN CAP 6µF 1.000 8 SD092151 RELAY 1.000 9 SD089550 TIMER 1.000 10 SD038750 RUN CAP 15µF 1.000 11 SD072650 6 WAY TERM' BLOCK 1.000 12 SA146003 LOOM ASSY 1.000 13 SD188950 ROCKER SWITCH 1.000 15 SA336550 TRANSFORMER 12v 1.000 16 SD378350 RELAY C/O 25A 12v COIL 1.000 17 D219350 COVER 1.000 ELEC BOX ASSY DH50/50(7)/60/60(7)AXP SA144809 1 SD139750 ELECTRICS BOX 1.000 3 SD041450 CONTROL KNOB 1.000 4 SD349351 GASKET 1.000 5 SD062350 HUMIDISTAT 1.000 7 SD022150 FAN CAP 6µF 1.000 8 SD092151 RELAY 1.000 9 SD089550 TIMER 1.000 10 SD038750 RUN CAP 15µF 1.000 11 SD072650 6 WAY TERM' BLOCK 1.000 12 SA146502 LOOM ASSY 1.000 13 SD188950 ROCKER SWITCH 1.000 14 SD145803 TIMER/DEFROST STAT 1.000 15 SA336550 TRANSFORMER 12v 1.000 16 SD378350 RELAY C/O 25A 12v COIL 1.000 17 D219350 COVER 1.000 page62 SD139460 ISSUE 21 10 23 18 21 4 12 FAN CONTINUOUS 22 2 20 5 34 19 17 16 1 SA144810 FAN ELECTRIC BOX ASSEMBLY DH60AHP CYCLE ASSY No SA144810 AT ISS 4 (15/09/2011). ELECTRIC BOX ASSY DH60AHP ITEM NO. PART No. 1 2 4 5 10 12 16 17 18 19 20 21 22 23 34 SD139750 SD336551 SD219350 SD378350 SD189050 SD349351 SD118351 SD382450 SD092151 SD089550 SD038750 SD072650 SA146004 SD188950 SP147450 DESCRIPTION ELECTRIC BOX TRANSFORMER 12V 12VA COVER RELAY 25A C/O 12V COIL LABEL ROCKER SWITCH GASKET FOR COVER THERMOSTAT PRESET CAPACITOR 5uF 440V 50/60Hz RELAY N/O 1POLE 30A 230V AC COIL DELAY TIMER 7 SEC TO 9 MIN CAPACITOR RUN CAP 15µF+/-5% 400V TERMINAL BLOCK 6 WAY DH60AHP LOOM ASSY ROCKER SWITCH 1 POLE C/O DOUBLE SIDED ADHESIVE PAD 25mm page63 QUAN UNITS 1 1 1 2 1 1 1 1 1 1 1 1 1 1 3 off off off off off off off off off off off off off off off SD139460 ISSUE 21 DH30/30(7) GRP COVER ASSY SA223101 3 2 ITEM 1 2 3 PART No D140050 D139550 D141650 1 DESCRIPTION :COVER GRP LOUVRE SUPPORT (HONEYSUCKLE) LOUVRE (HONEYSUCKLE) page64 QUANTITY 1 3 4 SD139460 ISSUE 21 DH30/30(7) METAL COVER ASSY'S. SEE PARTS LISTS 3 4 off 2 3 off 1 DH30 /37 PLASTISOL COVER ASSY SA210801 :ITEM 1 2 3 PART No D163601 D139551 D141652 DESCRIPTION COVER PLASTISOL GREY LOUVRE SUPPORT GREY LOUVRE GREY QUANTITY 1 3 4 DH30 /37 STAINLESS STEEL COVER ASSY SA210802 :ITEM 1 2 3 PART No D163602 D139552 D141654 DESCRIPTION QUANTITY COVER STAINLESS STEEL 1 LOUVRE SUPPORT ALUMINIUM 3 LOUVRE ALUMINIUM 4 page65 SD139460 ISSUE 21 DH33/33(7) GRP COVER ASSY'S SEE PARTS LISTS SEE FIG 1 2 1 8.00 ± 2.00 3 FIG 1. 4 5 LOUVRE MOULDED COVER LOUVRE IS FIXED TO COVER WITH FIXING PIN ITEM 3 AND HELD IN POSN' WITH SPRING ITEM 5 AND PUSH NUT ITEM 4. TO DIM' AS SHOWN.(IN 2 POSNS) COVER ASSY HONEY BEIGE SA223103 :ITEM 1 2 3 4 5 PART No SD263050 SD264201 SD264450 SD279550 SD284550 DESCRIPTION QUANTITY MOULDED COVER 1 LOUVRE ASSY (3 LOUVRES) 1 MOULDED FIXING PIN 2 PUSH NUT 2 COMPRESSION SPRING 2 COVER ASSY WHITE SA223105 :ITEM 1 2 3 4 5 PART No SD263052 SD264203 SD264451 SD279550 SD284550 DESCRIPTION QUANTITY MOULDED COVER 1 LOUVRE ASSY (3 LOUVRES) 1 MOULDED FIXING PIN 2 PUSH NUT 2 COMPRESSION SPRING 2 page66 SD139460 ISSUE 21 page67 SD139460 ISSUE 21 1 4 off ITEM 1 2 3 PART No D140350 D139550 D141651 PARTS LIST :- 3 4 off SA223102 DH50/50(7) GRP COVER ASSY DESCRIPTION QUANTITY GRP COVER 1 LOUVRE SUPPORT HONEYSUCKLE 4 LOUVRE HONEYSUCKLE 4 2 page68 SD139460 ISSUE 21 1 DESCRIPTION QUANTITY COVER PLASTISOL GREY 1 LOUVRE SUPPORT GREY 4 LOUVRE GREY 4 ITEM 1 2 3 DESCRIPTION COVER STAINLESS STEEL LOUVRE SUPPORT ALUMINIUM LOUVRE ALUMINIUM QUANTITY 1 4 4 PART No D166002 D139552 D141655 PART No D166001 D139551 D141653 ITEM 1 2 3 SEE PARTS LISTS DH60/60(7) STAINLESS STEEL COVER SA64210804 :- 3 DH60/60(7) PLASTISOL COVER ASSY SA210803 :- 2 DH60/60(7) METAL COVER ASSY'S page69 SD139460 ISSUE 21 5 4 3 PART No SD263060 SD264205 SD264450 SD279550 SD284550 DESCRIPTION MOULDED COVER HONEY BEIGE LOUVRE ASSY HONEY BEIGE (2 LOUVRES) FIXING PIN PUSH NUT COMPRESSION SPRING FIG 1. LOUVRE IS FIXED TO COVER WITH FIXING PIN ITEM 3 AND HELD IN POSN' WITH SPRING ITEM 5 AND PUSH NUT ITEM 4 TO DIM' AS SHOWN.(IN 4 POSN'S) MOULDED COVER LOUVRE 8.00 +/-2.00 PARTNo SD263061 SD264206 SD264451 SD279550 SD284550 DESCRIPTION QUANTITY MOULDED COVER WHITE 1 LOUVRE ASSY WHITE (2 LOUVRES) 2 FIXING PIN 2 PUSH NUT 2 COMPRESSION SPRING 2 ITEM 1 2 3 4 5 QUANTITY 1 2 2 2 2 2 ITEM 1 2 3 4 5 1 COVER ASSY WHITE SA223108 :- 2 COVER ASSY HONEYBEIGE SA223107 :- SEE FIG 1. SEE PARTS LISTS DH55/55(7) GRP COVER ASSY'S 7.0 OPTIONAL KITS 7.1 LPHW ASSEMBLIES L.P.H.W. ASSEMBLIES FOR DH33/33(7) & DH55/55(7) 6 1 8 7 LPHW ASSY DH33 SA281901 ITEM 1 6 7 8 PART No SD251750 SD284450 SA253954 SD091050 DESCRIPTION QUANTITY LPHW FIN BLOCK 1 AIR BLEED VALVE 1 THERMOSTAT CALIBRATED TO 40°C 1 PHIAL CLIP 1 LPHW ASSY DH55 SA281902 ITEM PART No DESCRIPTION 1 SD251751 LPHW FIN BLOCK 6 SD284450 AIR BLEED VALVE 7 SA253954 THERMOSTAT CALIBRATED 40°C 8 SD091050 PHIAL CLIP page70 QUANTITY 1 1 1 1 SD139460 ISSUE 21 7.2 12V REMOTE HUMIDISTAT KIT IF NOT ALREADY FACTORY FITTED 01/03 02/04 D372752 D372753 DH33/33(7)/55/55(7)A DH33/33(7)/55/55(7)AX NOTES 1. SEE WIRING DIAGRAMS FOR CONNECTION & ALTERATIONS T0 ELEC BOX ASSY'S 5 THIS ITEM REPLACES MAINS IN TB ON ELEC BOX ASSY 2 3 BLUE PINK ORANGE BROWN B 12V REMOTE HUMIDISTAT KIT SA381001/02/03/04 ITEM 2 3 5 PART No SD336550 SD378350 SD072853 DESCRIPTION TRANSFORMER 0-12 (12V) RELAY 25A 12V COIL 15A 5 WAY TERM BLOCK page71 QUANTITY 1.000 1.000 1.000 SD139460 ISSUE 21 7.3 12V REMOTE HUMIDISTAT CONNECTIONS 12v REMOTE HUMIDISTAT CONNECTIONS HUMIDISTAT (NOT SUPPLIED, WE RECOMMEND CALOREX PART SD385250. SIEBE PART No.119 1701 91100) E N L Remote Control Interface 250M MAX 1mm SQ CABLE WITH REMOTE HUMIDISTAT FITTED ENSURE HUMIDISTAT IN MACHINE IS SET FULLY CLOCKWISE (IE MAXIMUM DEHUMIDIFICATION) 12v REMOTE AIR THERMOSTAT CONNECTIONS AIR STAT (NOT SUPPLIED, WE RECOMMEND CALOREX PART SD385251. SOPAC JAEGER TYPE TA630.01, INTERCONTROL PART No.Q302.07). E N L Remote Control Interface 250M MAX 1mm SQ CABLE 12v REMOTE AIR THERMOSTAT CONNECTIONS FOR M/C WITH RESISTANCE HEATERS page72 SD139460 ISSUE 21 7.4 WEIR KIT AUXILIARY DRIP TRAY (WEIR) KIT 2 2 off EV AP OR AT OR 1 64 ,0 0 APERTURE KIT FOR DH30/33 SD64229501 :ITEM 1 - SD64218750 DRIP TRAY ITEM 2 - D64229650 STRIP KIT FOR DH50/55/60 SD64229502 :ITEM 1 - SD64218751 DRIP TRAY ITEM 2 - D64229650 STRIP page73 SD139460 ISSUE 21 7.5 AIR FILTER KITS FRONT COVER WALL 4 5 FIXING TAPE OR FILTER REAR SUPPORT BRACKET 2 1 3 AIR FILTER KIT DH30/30(7) GRP COVER ITEM 1 2 3 4 5 PART No SD171950 SD172350 SD180250 SD180450 SD180451 DESCRIPTION FILTER HOLDER FILTER SUPPORT BRACKET FILTER MEDIA FIXING TAPE HOOK FIXING TAPE LOOP QUANTITY 1.000 1.000 1.000 0.700 M 0.700 M AIR FILTER KIT DH50/50(7) GRP COVER ITEM 1 2 3 4 5 PART No SD171951 SD172351 SD180251 SD180450 SD180451 DESCRIPTION FILTER HOLDER FILTER SUPPORT BRACKET FILTER MEDIA FIXING TAPE HOOK FIXING TAPE LOOP QUANTITY 1.000 1.000 1.000 1.150 M 1.150 M AIR FILTER KIT DH30/30(7) STEEL COVER ITEM 1 2 3 4 5 PART No SD171952 SD172451 SD180250 SD180450 SD180451 DESCRIPTION FILTER HOLDER FILTER SUPPORT BRACKET FILTER MEDIA FIXING TAPE HOOK FIXING TAPE LOOP QUANTITY 1.000 1.000 1.000 0.730 M 0.730 M AIR FILTER KIT DH60/60(7) STEEL COVER ITEM 1 2 3 4 5 PART No SD171953 SD172450 SD180251 SD180450 SD180451 DESCRIPTION FILTER HOLDER FILTER SUPPORT BRACKET FILTER MEDIA FIXING TAPE HOOK FIXING TAPE LOOP page74 QUANTITY 1.000 1.000 1.000 1.190 M 1.190 M SD139460 ISSUE 21 7.5 AIR FILTER KITS CONT FRONT COVER 2 1 AIR FILTER KIT DH33/33(7) GRP COVER(282101) ITEM 1 2 PART No DESCRIPTION QUANTITY SD268650 FILTER SUPPORT CHANNEL 1.000 SD264650 FILTER ASSY 1.000 AIR FILTER KIT DH55/55(7) GRP COVER(282102) ITEM ITEM 1 ITEM 2 PART No DESCRIPTION QUANTITY SD268651 FILTER SUPPORT CHANNEL 1.000 SD264651 FILTER ASSY 1.000 page75 SD139460 ISSUE 21 7.6 FLOOR STAND KITS SA64180901/02 105.00 758.00 300.00 'X' SEE TABLE 280.00 USED ON DH30/33/3010 DH50/55/5010 STAND PART No SD64172050 SD64172051 DIMENSION 'X' 750.00mm 1070.00mm ASSEMBLY INSTRUCTIONS SHEET SD64326450 page76 SD139460 ISSUE 21 7.7 REMOVAL AND SERVICING OF DRIPTRAY 1.IMPORTANT BEFORE REMOVING COVER, ISOLATE POWER FROM DEHUMIDIFIER. 2. REMOVE SCREWS FROM POSITION SHOW AND REMOVE COVER OF MACHINE DRIPTRAY BRACKET 3. LOOSEN SCREWS FROM BUSHES SHOWN AND SLIDE BOTTOM BRACKET AWAY. 4. PULL DRIPTRAY DOWN TO REMOVE AND SERVICE AS REQUIRED. 5. REVERSE STEPS 1-4 TO REPLACE DRIPTRAY, BRACKET AND COVER. NOTE: DH33 STYLE DEHUMIDIFIER SHOWN. page77 SD139460 ISSUE 21 8.0 WARRANTY CONDITIONS The following exclusions apply to the Warranty given by Calorex Heat Pumps Ltd. No claims will be accepted if :1. The dehumidifier is incorrectly sized for the application. 2. The dehumidifier is installed in any way that is not in accordance with the current procedures as defined by Calorex Heat Pumps Ltd. 3. The dehumidifier has been worked upon or is adjusted by anyone other than a person authorised to do so by Calorex Heat Pumps Ltd. 4. The air flow through the machine is outside the specified limits. 5. The water flow through the machine is outside the specified limits. 6. The water pH level and/or chemical balance is outside the following limits:- Acidity pH Total Alkalinity, as CaCO3 pH ppm 7.4 - 7.8 80 - 120 Total Hardness, as CaCO3 ppm 150 - 250 Total Dissolved Solids ppm 1000 Maximum Salt Content Free Chlorine Range wt/wt ppm 8mg/l 1 - 2 Domestic Free Chlorine Range Superchlorination ppm max 3 - 6 Commercial 30ppm for 24 hrs Bromine Baquacil ppm ppm 2-5 25 - 50 Ozone Maximum Copper Content Aquamatic Ionic Purifier ppm ppm ppm 0.9 Max 1 2 Max 7. The dehumidifier has suffered frost damage. 8. The electrical supply is insufficient or in anyway incorrect. IF IN DOUBT PLEASE ASK Note:- The Reply Paid Warranty Registration Card must be returned, to ensure that the correct warranty is given. If you do not find a Registration Card with your Dehumidifier please contact the Calorex Service Department giving your name, address and serial number of your Dehumidifier. A card will be sent to you for completion. Please give MODEL NUMBER and SERIAL NUMBER of your Dehumidifier when making technical or service enquiries. This will assist in correct diagnosis and ensure service can provide with a minimum delay. PHONE 01621 857171 FAX 01621 850871 Email [email protected] Web Site http://www.calorex.com page78 SD139460 ISSUE 21
Similar documents
Technical Manual DH150/DH300/DH600
Please read these instructions carefully as they will enable you to get maximum efficiency and reliability from your new Calorex Dehumidifier.
More information