Technical Manual DH150/DH300/DH600
Transcription
Technical Manual DH150/DH300/DH600
Please read these instructions carefully as they will enable you to get maximum efficiency and reliability from your new Calorex Dehumidifier. Technical Manual DH150/DH300/DH600 (SD208060 Iss 10) 29/09/10 HEALTH AND SAFETY WARNING As the dehumidifier embodies electrical and rotational equipment, ONLY competent persons should carry out any work on this type of machine. (See Guarantee). Page 24 CONTENTS 11.0 WHAT ARE THE CALOREX DEHUMIDIFIERS DESIGNED TO DO ? ........................................................... 2 2.0 ORDERING PROCEDURE (MODEL DESIGNATION) ..................................................................................... 3 3.0 INSTALLATION ............................................................................................................................................. 3 3.1 SITING ...................................................................................................................................... 3 3.2 DUCTING (See figs 3, 4, 5 and 6) ............................................................................................ 4 3.3 PLUMBING ............................................................................................................................... 6 3.4 ELECTRICAL (MACHINE WIRING AND SUPPLY) .................................................................... 7 4.0 CONTROLS AND INDICATION LAMPS ........................................................................................................ 9 5.0 DEHUMIDIFIER MALFUNCTION .................................................................................................................. 10 6.0 DEHUMIDIFIER TECHNICAL DATA SHEET .................................................................................................. 11 7.0 INSTALLATION DRAWINGS ........................................................................................................................ 12 8.0 LOW PRESSURE HOT WATER (LPHW) HEATER BATTERY OPTION ........................................................ 14 9.0 DH150 WITH TOP DISCHARGE BOX OPTION ............................................................................................ 15 10.0 DH600 WITH TOP DISCHARGE BOX OPTION .......................................................................................... 16 11.0 ELECTRICAL CIRCUIT DIAGRAMS ........................................................................................................... 17 12.0 WARRANTY CONDITIONS ......................................................................................................................... 24 13.0 MACHINE RECORD LOG ........................................................................................................................... 25 14.0 PERFORMANCE GRAPHS ......................................................................................................................... 26 15.0 REFRIGERATION DIAGRAMS ..................................................................................................................... 27 16.0 WIRING DIAGRAMS .................................................................................................................................. 29 17.0 SPARE PARTS ........................................................................................................................................... 35 17.1 CONSOLE ASSEMBLIES ....................................................................................................... 35 17.2 SWITCH BRACKET ASSEMBLIES ........................................................................................ 37 17.3 ELECTRIC BOX ASSEMBLIES .............................................................................................. 38 17.4 MAIN ASSEMBLIES ............................................................................................................... 50 17.5 HEATER BOXES ...................................................................................................................... 67 17.6 LPHW KIT .............................................................................................................................. 73 17.7 DUCTING................................................................................................................................ 74 Page 25 1.0 WHAT ARE THE CALOREX DEHUMIDIFIERS DESIGNED TO DO ? Models DH150, DH300 & DH600 are designed to remove moisture from the air and reject the latent heat of the dehumidification process back into the air. Warm, humid air is drawn in through the evaporator which extracts the latent heat and at the same time dehumidifies the air by cooling it below its dew point temperature. The condensed moisture forms on the evaporator coil and is then drained to waste. The extracted heat is then upgraded to a much higher temperature by the compressor and passes into the condenser coil. The cool, drier air then passes over the condenser, collects the heat and passes back into the room as warm, dry air. Fig. 1. Page 2 2.0 ORDERING PROCEDURE (MODEL DESIGNATION) EXAMPLE:- DH 600 B Y S R F High output fan to combat extended duct work. Remote control facilities. ‘S’ signifies soft start kit fitted. To be used ONLY where local electricity boards demand lower instantaneous starting amps and not to overcome a suspect supply line, ie low voltage. ‘X’ models ambient air temperatures down to 0ºC (DH150 only). ‘Y’ models ambient air temperatures down to -15ºC (DH300/600 only). A = 230V ~1phN 50Hz (model 150 only). B = 400V ~3phN 50Hz. D = 208-230V ~1ph 60Hz (model 150 only). E = 200-230V ~3ph 60Hz. 00 = R407c models design limitations are:Max air on temperature = 35ºC. DH = Dehumidifier with heat reclaim to air. 3.0 INSTALLATION Great care should be exercised in following the installation procedure to ensure that your Calorex dehumidifier performs as it was designed. 3.1 SITING a. Ensure dehumidifier on site is as ordered, i.e. model, electrical supply and factory fitted options. b. Inspect unit for damage, in particular inspect the evaporator (finned side) to ensure that it is undamaged. (Minor indentations in the fins do not affect performance). If severely damaged, endorse delivery note in presence of the driver and send a recorded delivery letter to transport company giving details. c. Protect unit if installation is delayed. d. Provide a firm level base capable of supporting operational weight of unit; spread load if on timber floor. e. Ensure water cannot collect under unit, recommend units are installed on plinths 100mm above finished floor level and to also aid condensate drainage. f. Allow adequate clearance to service panels on unit; recommend 500mm minimum (see installation drawings). g. All Calorex dehumidifiers are by design as quiet as is practicable, however, due consideration should be given to siting in order to fully exploit this feature, i.e. orientate inlet/outlet parallel to occupied premises. h. Ensure loose debris will not block air inlet filters or grilles. Page 3 SITING cont’ IMPORTANT:As dehumidifier units are handling air at dehumidified space temperatures, they must be sited in a similar environment, or insulated plenum. They must not be sited in colder areas, i.e. subject to ambient air. 3.2 DUCTING (See figs 3, 4, 5 and 6) In order that moisture can be removed and humidity control can be effected within the required area, it is essential that correct air movement and distribution is achieved. The Calorex unit must extract the humid air generated and discharge the drier air to areas which are subject to condensation problems (windows, etc.) and or comfort zones, etc. This can often be achieved by use of ducting and correct application of grilles/louvres to effect air distribution and movement to these areas. NOTE:- Dehumidifier unit and ducting will be at higher temperature and will require insulation if exposed to lower air Fig. 2. Calorex Dehumidifier installed within space to be dehumidified, with top discharge box option fitted. Fig. 3. Calorex Dehumidifier installed within space to be dehumidified, with discharge ducting fitted. Page 4 DUCTING cont’ temperatures, for instance, if the ducting were to pass through an un-heated loft space. Exhaust from Wet Area - Humid Air - Should be taken from as low as practicable to inlet of Dehumidifier unit. In many instances siting of Dehumidifier unit in hall or in adjacent rooms can eliminate use of ductwork to inlet. Inlet/Return - Dry Air - Frequently requires overhead ducting with suitable grilles to give balance and direction of air flow. The quantity of air flow handled by each Dehumidifier unit is given on the data sheet together with the maximum pressure available from the fan to overcome total ducting resistance to air flow, i.e. inlet, discharge ducting, grilles, filters and where, installed air heater batteries. Note:a. The humidity sensing tube situated by the air inlet is to be encompassed by or extended to any inlet air ducting. Refer to installation drawings. b. All units have discharge ducting spigots as standard. c. Inlet ducting spigots and or inlet air filters are available from stockists. Do not drill into unit to fit spigots or filters. d. Final connections to Dehumidifier spigots must be made with flexible ducting (rubber or canvas) to eliminate transmission of vibration down any ducting fitted. e. Before any discharge ducting is attached remove plate (if fitted) from machine outlet or fan grille. f. After completion of installation including all grilles, ductwork, etc., ensure that the air flow through the machine is as specified in the data sheet ± 10%. If airflow is high, adjust the main system damper to obtain correct airflow. If airflow is low or high, unit will not function correctly. g. TABLE 1. Required Free Areas to provide air flow to and from Dehumidifiers when installed in an enclosed area or where required to pass air through a wall, etc. Free area is the available area through which air can pass, through a grille or louvres. Model DH150 - minimum free area air inlet = 0·35 m². Model DH300 - minimum free area air inlet = 0·57 m². Model DH600 - minimum free area air inlet = 1·1 m². Note: If multiple units are installed in an enclosed area then the inlet free areas required for each unit can be added together to form one inlet aperture. BUT discharge from each unit must be kept separate and must not be incorporated into one common duct system, unless back draft flaps are installed in outlet duct of each machine. Fig. 4. Calorex Dehumidifier installed within space to be dehumidified, with top discharge box option and flexible ducting fitted. Page 5 DUCTING cont’ Fig. 5. Calorex Dehumidifier installed in plenum chamber, with top discharge ducting fitted. 3.3 PLUMBING a. The condensate drain at the base of the unit collects the condensation from the evaporator fins. It is therefore necessary to ensure that the Calorex Dehumidifier is placed on a level plinth so that the condensate water can run away and not overflow the edges of the drip tray inside the machine. Calorex Dehumidifiers have condensate water outlet connections as follows:Models DH150 = 22mm push fit Domestic Waste system. Models DH300 = ¾" BSPM stub. Models DH600 = 1½” BSPM stub. Fig. 6. Calorex Dehumidifier with Condensate Pump Option fitted. For applications where the condensate cannot be run to waste due to the dehumidifier being lower than the waste pipe outlet, a condensate pump option can be supplied. (Located externally on the DH300 model and internally on the DH150 and DH600 models). Page 6 3.4 ELECTRICAL (MACHINE WIRING AND SUPPLY) a. To be in accordance with I.E.E. standards, latest issue, or local codes of practice as applicable. b. Protected supply to incorporate fuses or motor rated circuit breakers to specified rating, (see Data Sheet). H.R.C. fuses are recommended. An isolator which disconnects all poles must be fitted adjacent to machine. c. All units must be correctly earthed/grounded. An earth leakage trip of the current operating type is recommended to be fitted to all electrics. d. IMPORTANT:- Inconsistent Electrical Supply. The following Iimits of operation list not be exceeded if Calorex machines are to be guaranteed either in performance or warranty terms: Single phase machines (nominal 230V); Voltage limits = 207V/253V min/max. Three-phase machines (nominal 400V); Voltage limits = 360V/440V min/max. Cycle (nominal 50Hz); Frequency limits = 47·5Hz/52·5Hz min/max. N.B. This voltage must be available at the Dehumidifier whilst it is running under full load. The machine should be installed in accordance with EMC2004/108/EC. Note: All machines are fitted with a phase protection relay and will not run if the phases are not connected in correct order (phase sequence) or if the supply voltage is 15% less than the nominal voltage. (415V for 3~N 50Hz). The lamp on the phase rotation relay, situated in the electric box, is illuminated when the phases are correctly connected and the voltage is sufficient. Fig.7. DH150, Location of Machine Supply Terminal Blocks ACCESS TO HEATER BOX TERMINALS (WHEN HEATER KIT FITTED) TOP DISCHARGE BOX (IF FITTED) REMOVE SERVICE PANEL (6 SCREWS) MAINS IN TERMINAL BLOCK AND EARTHING POINT REMOVE SERVICE PANEL (1/4 TURN FASTENERS) MAINS SUPPLY IN Page 7 Fig.8. DH300/600, Location of Machine Supply Terminal Blocks DH300/600 Mains Terminal Block and Earthing Point 1 Remove Front Service Panel (1/4 turn fasteners) 2 3 4 5 6 7 8 POOL PUMP N L1 L2 L3 INTERLOCK OR FLOW SWITCH Page 8 9 SOFT START 4.0 CONTROLS AND INDICATION LAMPS External Control Console. a. MAINS LAMP - RED - Illuminates whenever the electrical supply to the dehumidifier is on. b. FAULT LAMP - AMBER - Illuminates if the internal limit switches detect a problem, or if the external interlock facility is open circuit. c. DEFROST - WHITE - Illuminates whenever the dehumidifier is in defrost mode, this will happen at lower air temperatures and is not a fault condition, the dehumidifier will revert to normal run automatically when the defrost cycle is complete. d. ON/OFF SWITCH - This will only be found on DH150 models and should always be used if for some reason the dehumidifier is not required to be running or prior to isolating the dehumidifier from the mains electrical supply. e. STANDBY SWITCH - This will only be found on DH300/600 models and must always be used if for some reason the dehumidifier is not required to be running or prior to isolating the dehumidifier from the mains electrical supply. IMPORTANT - On initial start up or if the mains electrical supply has been interrupted for any length of time (greater than 1 hour), then the standby switch must be set to “standby” before the mains electrical supply is reinstated, the dehumidifier must be left in this condition for 12 hours before normal run is selected on the standby switch. Internal Controls. f. An adjustable internal humidistat effects control of humidity. Range 20/80%. Normal setting is 60% for achieving comfort conditions and minimising condensation. (20% setting will remove more moisture from the dehumidified space than a 80% setting). g. An adjustable thermostat effects control of the air temperature and should be set to the maximum desired air temperature for the dehumidified space. h. Fan mode switch. This gives the user the option of having the fan cycle under control of the humidistat (with the compressor), or the fan can run continuously which will promote better air circulation which again helps to reduce condensation by preventing stagnant air pockets. i. If the Turning Hood Top Box Heater assembly option is fitted, then the adjustable air temperature thermostat control, located on the side of the Top Box Heater assembly should be set to the desired minimum air temperature required. Page 9 5.0 DEHUMIDIFIER MALFUNCTION WARNING : ISOLATE MACHINE ELECTRICALLY BEFORE ENTERING MACHINE OR REMOVING PANELS. The user check list should be carried out by a competent electrician before initiating a service call. Do not attempt to interfere with any internal control settings as these have been factory calibrated and sealed. If in doubt or if advice is required. Contact Calorex Service Department :Phone +44(0)1621 857171 or +44(0)1621 856611. Fax +44(0)1621 850871. USER CHECK LIST FAN AND COMPRESSOR BOTH OFF. LAMP TYPE. LAMP COLOUR. LAMP STATE. ACTION. Check that the electrical supply and supply fuse (or MCB) to the MAINS. RED. OFF. dehumidifier are healthy and switched on. FAULT. AMBER. OFF. DEFROST WHITE. OFF. Check that the on/off rocker switch is "ON" (DH150 only). ON/OFF. RED. OFF. MAINS. FAULT. DEFROST ON/OFF. RED. AMBER. WHITE. RED. ON OFF. OFF. OFF. Check control MCB is on (DH300/600 three phase machines only) FAN ON, COMPRESSOR OFF. LAMP TYPE. LAMP COLOUR. LAMP STATE. ACTION. Check humidistat is calling for the dehumidifier to run and that the air MAINS. RED. ON. temperature thermostat is not exceeded. FAULT. AMBER. OFF. DEFROST WHITE. OFF. Check internal fuses/overloads. Check "Standby" switch "ON" (if fitted). ON/OFF. RED. ON. LAMP TYPE. LAMP COLOUR. LAMP STATE. ACTION. MAINS. RED. ON. Check air flows are not restricted. Re-set HP switch on DH300 & DH600. FAULT. AMBER. ON. Check thermal cut out on soft start and heater hood if fitted. DEFROST WHITE. OFF. Check fan for correct rotation (DH300/600). ON/OFF. RED. ON. LAMP TYPE. LAMP COLOUR. LAMP STATE. ACTION. Check that the air temperature is above 0ºC for DH150's, and above -15ºC MAINS. RED. ON. for DH300/600. FAULT. AMBER. OFF. Note :- It is acceptable for the dehumidifier to cycle on the defrost light DEFROST WHITE. ON. ON/OFF. RED. ON. once per hour at low air temperatures. Any sign of abnormal operation, such as water dripping should be reported immediately to an installer or Calorex Page 10 6.0 DEHUMIDIFIER TECHNICAL DATA SHEET MODEL NUMBER 1Ø 3Ø DH150AX DH150BX N/A DH300BL(Y) N/A DH600BY PERFORMANCE DATA Dehumidification Rate l/hr 6·25 12·5 25 Output to Air Nett (DH model) kW 5·5 15·5 25 Total Electrical Input (STD fan) kW 2·5 6·7 10·0 Total Electrical Input ("F" fan) kW 2·9 7·3 10·4 ELECTRICAL DATA Supply Details 1Ø |---230V~1N 50Hz-----| N/A N/A Supply Details 3Ø |------------------------------------ 400V ~3N 50Hz -------------------------------------| Fan Option Type STD "F" STD "F" STD "F" Maximum Supply Fuse 1Ø amps 30 30 N/A N/A N/A N/A Maximum Supply Fuse 3Ø amps 16 16 24 25 35 35 Maximum Running Amps 1Ø amps 19 20 N/A N/A N/A N/A Maximum Running Amps 3Ø amps 8.1 9·9 15 16 26 27 Starting Current Amps 1Ø STD M/C amps 61 N/A N/A Starting Current Amps 1Ø "S" M/C amps 28 N/A N/A Starting Current Amps 3Ø STD M/C amps 30 101 135 Starting Current Amps 3Ø "S" M/C amps 13 34 55 AIR HEATER OPTION If Turning Hood with Heater fitted:Separate Supply for heaters Maximum Power Output kW 9 N/A N/A Maximum Full Load Amps 1Ø amps 36 N/A N/A Maximum Full Load Amps 3Ø amps 12 N/A N/A Maximum Supply Fuse 1Ø amps 50 N/A N/A Maximum Supply Fuse 3Ø amps 16 N/A N/A AIR FLOW DATA Air Flow Nominal m³/hr 2200 5000 9000 Ducting Max' Static Pressure STD M/C mmWG 3 6 8 Ducting Max' Static Pressure "F" M/C mmWG 17 14 16 If Turning Hood with Heater fitted:Ducting Max' Static Pressure STD M/C mmWG 0 N/A 0 Ducting Max' Static Pressure "F" M/C mmWG 14 N/A 8 WATER FLOW DATA Condensate Water Connection Size ¾"Domestic Waste 1½"BSPM 1½"BSPM PHYSICAL DATA Width (unpacked) mm 660 980 1730 Depth (unpacked) mm 660 720 1250 Height (unpacked) mm 1313 1435 1600 Weight (unpacked) kg 130 220 497 MISC' DATA Hermetic System Refrigeration charge R407c (STD DH) kg 2·5 9.5 14 Refrigeration charge R407c (DH300BLY) kg 10 Sound Level at 3m dbA 58 66 63 NOTES:1) Performance data based on air at 20ºC, 75%RH (Water at 26ºC). 2) Weight and dimensions nett. 3) Allow 500mm clearance to service panels. 4) Minimum air temperature 0ºC for "X" models and -15ºC for "Y" models. 5) Calorex reserve the right to change or modify models without prior notice. 6) R407c Global Warming Potential (GWP) 1700 Page 11 7.0 INSTALLATION DRAWINGS DH150 DEHUMIDIFIER. SERVICE PANEL FRONT SERVICE PANEL 152 SEE NOTE AT FOOT OF PAGE AIR OUTLET 355 660 TOP VIEW 660 100 50 268 186 510 REAR VIEW L H SIDE DISCHARGE LIQUID A/C RCU MODELS ONLY FRONT SERVICE PANEL 280 AIR SAMPLING POINT * DRAIN AIR INLET MAINS INLET 645 940 720* 517 1262 50 265 OPTIONAL AIR OUTLET 129 197 75* 156 50 WATER OUT 51 139 190 527 557 WATER IN 524 (DHW MODEL ONLY) NOTE:- Dimensions marked * refer to dimensions of inlet DUCT FLANGE KIT OPTION (50mm Deep). DH150 DEHUMIDIFIER - WHEELS AND HANDLES OPTION (DH150BX ONLY) 660 197 266 355 AIR OUTLET 152 660 TOP VIEW 1087 934 660 660 100 152 FRONT VIEW REAR VIEW 266 510 355 50 55 FRONT SERVICE PANEL OPTIONAL AIR OUTLET 1252 720 AIR INLET 251 DRAIN 74 935 AIR SAMPLING POINT 330 Page 12 7.0 INSTALLATION DRAWINGS. cont’ DH300 DEHUMIDIFIER. 980 423 AIR OFF SERVICE PANEL 369 20 278 980 547 SERVICE PANEL *740 700 40 AIR OFF 1435 475 AIR INLET *775 216 640 SERVICE PANEL 613 DRAIN 680 DISPLAY CONSOLE 126 110 NOTE :- Dimensions marked * refer to dimensions of INLET DUCT FLANGE KIT OPTION (50mm Deep). DH600 DEHUMIDIFIER. NOTE:- Dimensions marked * refer to dimensions of inlet DUCT FLANGE KIT OPTION (50mm Deep). Page 13 8.0 LOW PRESSURE HOT WATER (LPHW) HEATER BATTERY OPTION For use with Calorex DH150 Dehumidifier only - available from your Calorex Distributor. MODEL LPHW580 Output (Water at 80ºC, Air at 30ºC) kW 18 Water Connections mm 22mm Stubs Water Pressure Drop psig 0·5 Water Flow l/min 23 Water Volume litres 2·5 Air Pressure Drop mmWG 2·5 Air Off Temperature ºC 50 Dimensions:- "A" mm 650 "B" mm 620 "C" mm 250 "D" mm 50 "E" mm 500 "F" mm 540 "G" mm 60 Page 14 Page 15 100.00 DIA 8" OR 12" OR 16" AIR INLET REAR VIEW 520.00 12", OR 8", OR 16" SPIGOTS ON ONE OR FOUR SIDES AS REQUIRED 100.00 HEATER KIT AND THERMOSTAT (IF FITTED) 110.00 L H SIDE 660.00 TOP VIEW AIR OUTLET RESET BUTTON 660.00 520.00 520.00 70.00 50.00 ADJUSTABLE DEFLECTOR GRILLE ON ONE OR FOUR SIDES AS REQUIRED FRONT SERVICE PANEL FRONT SERVICE PANEL 605.00 1262.00 SERVICE PANEL 9.0 DH150 WITH TOP DISCHARGE BOX OPTION WITH OR WITHOUT 9kW HEATER OPTION. Page 16 SERVICE PANEL 750.00 128.00 12" OR 8" DIA 100.00 490.00 REAR VIEW 1730.00 750.00 AIR OULTET TOP VIEW 1060.00 12" OR 8" SPIGOTS ON ONE OR FOUR SIDES AS REQUIRED 100.00 L.H.SIDE ADJUSTABLE DEFLECTOR GRILLE ON ONE OR FOUR SIDES AS REQUIRED NOTE. 4 LOCKABLE CASTORS AVAILABLE AS OPTIONAL EXTRA SERVICE PANEL 965.00 1550.00 FRONT SERVICE PANEL SERVICE CONTROL PANEL FRONT VIEW AIR INLET 10.0 DH600 WITH TOP DISCHARGE BOX OPTION 11.0 ELECTRICAL CIRCUIT DIAGRAMS ELECTRICAL CIRCUIT DIAGRAM DH150AX SINGLE PHASE 230V 50Hz (~1N) FUSE VALUES L CONDENSATE PUMP CONTROL 1A 7A 1A 10A RELAY/HARD START CAP (IF FITTED) 1A 3A COMPRESSOR 3A 3A CONTACTOR 3A 3A R C 3A 6(NO) S DH150BX DH150BXF 5 RUN CAP PUMP (F4) 2(NO) SOFT START (IF FITTED) PHASE/R (F3) 1 HOURS RUN METER FAN CAP' FAN MOTOR MAKES 1-3 ON 2 TEMP FALLING PHASE/R (F2) A2 DELAY TIMER 4 (N/C) L3 L2 L1 (F1) (F2) L3 (F3) 14 L2 COM N/O PHASE ROTATION RELAY 1 HUMIDISTAT 2 H (N/C) C (COM) C (COM) L1 11 FAN FUSE (F5) HP SWITCH BREAKS ON PRESSURE RISING (N/C) L LP SWITCH 2 1 1 1 3 5 A2 2(NO) 4(NO) 6(NO) (N/O) 3 DELAY TIMER A (COM) 7 4 (N/C) CONDENSATE PUMP (IF FITTED) 2 W U N COMPRESSOR V SOFT START (IF FITTED) FAN CAP' FAN MOTOR RELAY 4 (N/O) B MAKES 1-3 ON TEMP FALLING DEFROST LAMP DEFROST VALVE HOURS RUN METER A1 (COM) 1 DEFROST THERMOSTAT 2 HIGH AIR LIMIT STAT CONTROL SWITCH 3 (F4) PUMP FUSE MAINS LAMP Page 17 2 3 OR FLOW SWITCH BREAKS ON PRESSURE FALLING 1 FAULT LAMP 1 1 1 DEFROST THERMOSTAT (COM) (N/O) DEFROST VALVE DEFROST LAMP FAN MODE SWITCH 1 2 2 CONDENSATE PUMP (IF FITTED) N CYCLE FAN (F5) PHASE/R (F1) A1 1 PUMP FUSE CONTROL SWITCH 3 C(COM) C(COM) H(N/C) INTERLOCK HIGH AIR LIMIT STAT HUMIDISTAT HP SWITCH (N/C)L BREAKS ON PRESSURE RISING LP SWITCH BREAKS ON PRESSURE FALLING CONTROL FUSE FAN MODE SWITCH MAINS LAMP INTERLOCK CONT CYCLE CONT FAULT LAMP 1A 10A DH150AXF 7A DH150AX WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CIRCUIT DIAGRAM,THEY ARE SHOWN IN DE-ENERGISED STATE WITH REFRIGERATION CIRCUIT FULLY CHARGED ELECTRICAL CIRCUIT DIAGRAM DH150BX STANDARD MACHINE THREE PHASE 400V 50Hz (~3N) FUSE VALUES WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CIRCUIT DIAGRAM,THEY ARE SHOWN IN DE-ENERGISED STATE WITH REFRIGERATION CIRCUIT FULLY CHARGED ELECTRICAL CIRCUIT DIAGRAM DH150BX WHEELS AND HANDLES VERSION THREE PHASE 400V 50Hz (~3N) FUSE VALUES PHASE/R PHASE/R PHASE/R DH150BX DH150BXF PUMP FAN (F4) (F5) (F1) (F2) (F3) 3A 3A 3A 1A 7A 3A 3A 1A 10A 3A WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CCT DIAGRAM,THEY ARE SHOWN IN DE-ENERGISED STATE WITH REFRIGERATION CIRCUIT FULLY CHARGED N L1 L2 L3 ISOLATOR CONTACTOR 1 2 (N/O) 3 4 (N/O) 5 6 (N/O) A1 (F1) (F2) COMPRESSOR U V W A2 (F3) HOURS RUN METER L1 L2 PHASE ROTATION RELAY L3 11 14 COM DELAY TIMER N/O RELAY No 1 (N/C) 1 A (COM) 7 B HIGH LEVEL FLOAT SWITCH RELAY No 2 PRESSURE RISING 9 (COM) H(N/C) A PUMP RUN FLOAT SWITCH B FAN CAP' C(COM) FAULT LAMP HP SWITCH BREAKS ON (N/O) 6 FAN FUSE FAN MOTOR (COM) 7 4 (N/O) RELAY No 3 (F5) CYCLE C(COM) CONTINUOUS LP SWITCH BREAKS ON PRESSURE FALLING (N/C)L FAN MODE SWITCH B 1 DEFROST THERMOSTAT (N/C) A MAKES 1-3 ON TEMP FALLING 2 4 (COM) 1 3 (N/O) DEFROST VALVE 1 HUMIDISTAT DEFROST LAMP 2 1 3 CONTROL SWITCH 2 CONDENSATE PUMP PUMP FUSE (F4) MAINS LAMP Page 18 11.0 ELECTRICAL CIRCUIT DIAGRAMS. cont’ ELECTRICAL CIRCUIT DIAGRAM DH300BY THREE PHASE 400V 50Hz (~3N) MCB SETTING VALUES DESCRIPTION COMPRESSOR FAN F FAN CONTROL PUMP CONTROL VALUE 20.16 2.04 2.63 2.5 2.0 MCB CONTACTS / MCB ALARM CONTACTS / MCB AUX CONTACTS SHOWN WITH CIRCUIT BREAKER MANUALLY SWITCHED TO THE ON CONDITION ALL OTHER CONTACTS SHOWN IN DE-ENERGISED STATE BUT WITH REFRIGERATION CIRCUIT FULLY CHARGED WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CIRCUIT DIAGRAM ABOVE CONDITIONS APPLY CONDENSATE PUMP/ L1 N CONTROL BOX CONDENSATE PUMP/ CONTROL BOX MCB 1 2(N/C) X PHASE ROTATION MAINS LIGHT RELAY CONTROL MCB 11(COM) X X 14(N/O) 6(N/C) 4(N/C) L1 2(N/C) L2 11 14 L3 (COM) 1 STANDBY SWITCH RUN (N/O) 2 3 (N/C) STANDBY MAKES 1 TO 3 ON TEMP FALLING 53 COMPRESSOR 3 MCB AUX NC DEFROST 1 54 STAT 4 (N/O) 54 (N/C) FAN MCB AUX NC (COM) 53 2 FAULT LIGHT C REVERSING VALVE HP SWITCH (BREAKS TO 'L' ON PRESSURE RISING) L(N/O) C(COM) CONT CYCLE SELECT H(N/C) SWITCH L(N/C) THERMAL O/LOAD AND LIGHT IF FITTED 8 7 6 DEFROST LIGHT CLOSE ON ABOVE CLOSE ON BELOW HUMIDITY SETTING TEMP SETTING 3 HUMIDISTAT 1 DELAY TIMER 2 AIR LIMIT STAT A2 A1 5 6(N/C) 5 6(N/O) 3 4(N/C) 3 4(N/O) 1 2(N/C) 1 2(N/O) A2 COMPRESSOR U A1 5 6(N/C) 5 6(N/O) 3 4(N/C) 3 4(N/O) 1 2(N/C) 1 2(N/O) MCB's W V FAN CONTACTORS Page 19 21 9 SOFT START 22 H(N/O) C(COM) COMP AUX (NC) LP SWITCH (BREAKS TO 'H' ON PRESSURE FALLING) HEATER(S) 1 X INTERLOCK TERMINALS 5 3 TERMINALS L2 INTERLOCK L3 11.0 ELECTRICAL CIRCUIT DIAGRAMS. cont’ ELECTRICAL CIRCUIT DIAGRAM DH300BL THREE PHASE 400V 50Hz (~3N) MCB SETTING VALUES DESCRIPTION COMPRESSOR FAN F FAN CONTROL PUMP CONTROL VALUE 20.16 2.04 2.63 2.5 2.0 MCB CONTACTS / MCB ALARM CONTACTS / MCB AUX CONTACTS SHOWN WITH CIRCUIT BREAKER MANUALLY SWITCHED TO THE ON CONDITION ALL OTHER CONTACTS SHOWN IN DE-ENERGISED STATE BUT WITH REFRIGERATION CIRCUIT FULLY CHARGED WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CIRCUIT DIAGRAM ABOVE CONDITIONS APPLY CONDENSATE PUMP/ L1 N CONTROL BOX CONDENSATE PUMP/ CONTROL BOX MCB 1 2(N/C) X PHASE ROTATION MAINS LIGHT RELAY CONTROL MCB 11(COM) X X 14(N/O) 6(N/C) 4(N/C) L1 2(N/C) L2 L3 (COM) 1 STANDBY SWITCH RUN (N/O) 2 3 (N/C) STANDBY 53 COMPRESSOR MCB AUX NC 54 53 FAN MCB AUX NC FAULT LIGHT 54 HP SWITCH C C(COM) (BREAKS TO 'L' ON PRESSURE RISING) CONT L(N/C) 9 SOFT START THERMAL O/LOAD AND LIGHT IF FITTED 8 7 6 DEFROST LIGHT CLOSE ON ABOVE HUMIDITY SETTING HUMIDISTAT CLOSE ON BELOW TEMP DEFROST SETTING 3 STAT 1 2 AIR LIMIT DELAY TIMER C L (COM) (N/C) STAT A2 5 6(N/C) A1 5 6(N/O) 3 4(N/C) 3 4(N/O) 1 2(N/C) 1 2(N/O) A2 V COMPRESSOR U A1 5 6(N/C) 5 6(N/O) 3 4(N/C) 3 4(N/O) 1 2(N/C) 1 2(N/O) MCB's W CONTACTORS Page 20 FAN 21 H(N/O) C(COM) 22 LP SWITCH (BREAKS TO 'H' ON PRESSURE FALLING) CYCLE SELECT SWITCH H(N/C) COMP AUX (NC) L(N/O) HEATER(S) 1 X INTERLOCK TERMINALS 5 3 TERMINALS L2 INTERLOCK L3 11.0 ELECTRICAL CIRCUIT DIAGRAMS. cont’ ELECTRICAL CIRCUIT DIAGRAM DH600BY THREE PHASE 400V 50Hz (~3N) DESCRIPTION COMPRESSOR FAN F FAN CONTROL PUMP CONTROL TRIPPING CURRENT 28.37 3.36 3.62 3.0 N/A SETTING VALUE 23.6 2.9 3.0 2.5 2.0 MCB CONTACTS / MCB AUX CONTACTS SHOWN WITH CCT BREAKER MANUALLY SWITCHED TO THE ON CONDITION. ALL OTHER CONTACTS SHOWN IN DE-ENERGISED STATE BUT WITH REFRIGERATION CIRCUIT FULLY CHARGED. WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CCT DIAGRAM ABOVE CONDITIONS APPLY. L1 PHASE ROTATION RELAY CONTROL MCB MAINS LIGHT (COM) X X X 4(N/C) L1 6(N/C) L2 11 14 L3 (COM) 1 STANDBY SWITCH RUN (N/O) COMPRESSOR 2 3 STANDBY (N/C) MAKES 1 TO 3 ON TEMP FALLING 54 MCB AUX (N) (NC) 1 4 3 53 DEFROST STAT FAN MCB AUX 2 54 FAULT LIGHT (NC) 53 COMPRESSOR (COM) MOTOR (N/C) (N/O) 1 PROTECTOR REVERSING VALVE C (COM) HP SWITCH BREAKS TO 'L' ON PRESSURE RISING CONT L (N/O) H (N/C) CYCLE SELECT SWITCH C (COM) LP SWITCH H (N/O) BREAKS TO 'H' ON PRESSURE FALLING L (N/C) DEFROST LIGHT O/LOAD AND LIGHT IF DELAY FITTED TIMER 3 2 1 HUMIDISTAT 1 2 AIR LIMIT STAT A2 A1 5 6(N/C) 5 6(N/O) 3 4(N/C) 3 4(N/O) 1 2(N/C) 1 2(N/O) L3 W L2 V COMPRESSOR U L1 TRIP/OFF = BREAK CONTACT A2 A1 5 6(N/C) 5 6(N/O) 3 4(N/C) 3 4(N/O) 1 2(N/C) 1 2(N/O) TRIP/OFF = BREAK CONTACT CONTACTORS MCBS Page 21 FAN 21 22 SOFT START THERMAL COMP AUX (NC) TO HIGH LEVEL CONDENSATE PUMP FLOAT SWITCH (IF FITTED) HEATER(S) 5 TERMINALS 3 (N/O) 2(N/C) INTERLOCK 1 N CONDENSATE PUMP/ CONTROL BOX (IF FITTED) CONDENSATE PUMP/ CONTROL BOX MCB (IF FITTED) TERMINALS L2 INTERLOCK L3 SINGLE PHASE HEATER BOX WIRING 230V 50Hz (~1N) W 0,5 G/Y 1,5 AIR STAT AUX R 1,0 BL 1,0 BL/W 0,5 R 1,0 GR/B 0,5 O 1,0 P 1,0 R 4,0 R 4,0 R 4,0 R 4,0 G 1,0 R 1,0 GR/B 0,5 O 1,0 P 1,0 BL 1,0 BL/W 0,5 B 1,0 G 1,0 BR 1,0 TO MODE SWITCH (CONTINUOUS) TO FAULT LAMP TO ON/OFF SWITCH TERM No2 TO FAN TERM BLOCK TO FAN TERM BLOCK TO DEFROST STAT TERM No4 TO FAN TERM BLOCK FROM FAN FUSE (WAS CONTROL FUSE) TO CONDENSATE PUMP FUSE LEAD Page 22 G/Y 1,5 R 2,5 R 4,0 B 4,0 G/Y 1,5 3A 50A R/B 0,5 R 2,5 5 1 FOR REF ONLY. TECASA (2) P (SOPAC JAEGER) (1) HIGH LIMIT STAT DELAY TIMER AIR HEATERS R 2,5 B 2,5 ISOLATOR SWITCH 4 6 2 W/R 0,5 B 2,5 95 96 B 2,5 EARTH STUD SEE D319052 FOR WIRING INSTRUCTIONS BLACK BLUE BROWN GREY ORANGE PINK RED WHITE VIOLET GREEN GREEN/YELLOW GREEN/RED BL B BR GR O P R W V G G/Y G/R L N 3 1 R 1,0 G 1,0 W/R 0,5 6 4 2 6 4 2 5 3 1 5 CONTACTOR CONTACTOR A2 A1 A2 3 B 1,0 1 A1 W 0,5 W 0,5 OTTER TEMP STAT B 2,5 B 2,5 B 2,5 BL 0,5 G 1,0 1 2 3 THREE PHASE HEATER BOX WIRING 400V 50Hz (~3N) OTTER TEMP STAT W 0,5 W 0,5 W 0,5 G/Y 1,5 BL/W 0,5 P 2,5 R 1,0 GR/B 0,5 O 1,0 P 1,0 R 1,0 GR/B 0,5 O 1,0 P 1,0 BR 1,0 GR 1,0 BL/W 0,5 BL 1,0 GR 1,0 BL 1,0 R 2,5 BL 2,5 R 2,5 R 2,5 B 1,0 P 2,5 B 1,0 R 1,0 W/R 0,5 P 2,5 G/Y 1,5 TO MODE SWITCH (CONTINUOUS) TO FAULT LAMP TO ON/OFF SWITCH TERM No1 TO FAN TERM BLOCK TO FAN TERM BLOCK TO FAN TERM BLOCK TO DEFROST STAT TERM No4 FROM FAN FUSE (WAS CONTROL FUSE) TO CONDENSATE PUMP FUSE LEAD Page 23 G/Y 1,5 R/BL 0,5 B 2,5 R/BL 0,5 W 2,5 3A 16A 16A 16A GR 1,0 R 2,5 BL 2,5 EARTH STUD ISOLATOR SWITCH N 2 4 6 NC 95 96 6 4 2 6 4 2 BL 0,5 SEE D319050 FOR WIRING INSTRUCTIONS FOR REF ONLY. 1 2 3 14 14 AIR STAT NO CONTACTOR NO CONTACTOR 1 TECASA (2) P (SOPAC JAEGER) (1) HIGH LIMIT STAT DELAY TIMER AIR HEATERS BLACK BLUE BROWN GREY ORANGE PINK RED WHITE VIOLET GREEN GREEN/YELLOW GREEN/RED BL B BR GR O P R W V G G/Y G/R L3 L2 L1 N 5 3 1 N 5 3 1 6 4 13 13 R 1,0 GR 1,0 W/R 0,5 2 5 3 1 A2 A1 A2 A1 B 2,5 B 2,5 12.0 WARRANTY CONDITIONS The following exclusions apply to the Warranty given by Calorex Heat Pumps Ltd. No claims will be accepted if :1. The dehumidifier is incorrectly sized for the application. 2. The dehumidifier is installed in any way that that is not in accordance with the current procedures as defined by Calorex Heat Pumps Ltd. 3. The dehumidifier has been worked upon or is adjusted by anyone other than a person authorised to do so by Calorex Heat Pumps Ltd. 4. The air flow through the machine is outside the specified limits. 5. The water flow through the machine is outside the specified limits. 6. The electrical supply is insufficient or in any way incorrect. 7. The dehumidifier has suffered frost damage. IF IN ANY DOUBT PLEASE ASK. Note:- The Reply Paid Warranty Registration Card must be returned, to ensure that the correct warranty is given. If you do not find a Registration Card with your Dehumidifier please contact the Calorex Service Department giving your name, address and serial number of yourDehumidifier. A card will be sent to you for completion. Please give MODEL NUMBER and SERIAL NUMBER of your dehumidifier when making technical or service enquiries. This will assist in correct diagnosis and ensure service can be provided with a minimum delay. PHONE +44(0)1621 857171 FAX +44(0)1621 850871 Email [email protected] Web Site http://www.calorex.com Page 24 13.0 MACHINE RECORD LOG In order to comply with European Union F-Gas regulations, it is necessary to leak test hermetically sealed systems with more than 6kg refrigerant annually. The operator of the unit is responsible for seeing that the test is carried out. For machines affected see datasheet section 7.0. A sample log sheet can be seen below. General Information Plant Name Location of Plant Plant Operator1 Operator Contact2 Refrigerant Type Plant manufacturer Serial Number Calorex Heat Pumps Limited Refrigerant Quantity installed (kg) Year of installation Refrigerant Additions Date Engineer3 Company Name Amount Added kg Reason for addition Amount Removed kg Reason for removal What done with recovered refrigerant Engineer Company Name Test Result Follow up action required Engineer Company Name Related to test on Actions taken Refrigerant Removals Date Engineer Company Name Leak Tests Date Follow up Actions Date Testing of Automatic Leak Detection System (if fitted) Date Engineer Company Name Test Result 1 Comments Name and address of company operating plant. Contact details for operator's nominated person responsible for F Gas compliance. 3 Company and technician carrying out work, with details to provide evidence of compliance. 2 Page 25 14.0 PERFORMANCE GRAPHS AIR TEMPERATURE (ºC) 30% DH150X 40% 50% 60% 70% SENSIBLE HEAT OUTPUT kW* TO AIR 80% 35ºC 10.8 3.2 30ºC 9.4 3.0 8.2 2.8 7.0 2.7 6.2 2.6 5.4 2.5 30%RH 40%RH 25ºC 50%RH 60%RH 20ºC 70%RH 80%RH 15ºC 10ºC 0 50 100 150 200 250 300 350 *At 75% RH LITRES/ 24 HOURS DH300Y 30% 40% 50% 60% 70% *SENSIBLE HEAT OUTPUT *kW TO AIR 80% 35ºC 40ºC AIR TEMPERATURE (ºC) 35ºC 30ºC 30%RH 30ºC 25ºC 40%RH ELECTRICAL INPUT *kW 22.4 6.8 19.8 6.2 17.5 5.9 15.1 5.5 13.3 5.1 11.4 4.7 50%RH 25ºC 60%RH 20ºC 20ºC 70%RH 80%RH 15ºC 15ºC 10ºC 0 100 200 300 400 500 600 700 800 *AT 75% RH LITRES/ 24 HOURS SENSIBLE HEAT OUTPUT *kW TO AIR DH600Y 30% 40% 50% 60% 70% ELECTRICAL INPUT *kW 80% 35 ºC 30 ºC AIR TEMPERATURE (ºC) ELECTRICAL INPUT kW* 30%RH 40%RH 25 ºC 43 13.0 38 12.0 34 11.3 29 10.5 25 9.8 50%RH 60%RH 20 ºC 70%RH 80%RH 15 ºC 10 ºC 22 0 200 400 600 800 1000 1200 LITRES/ 24 HOURS Page 26 1400 9.0 * AT 75% RH 15.0 REFRIGERATION DIAGRAMS 3/8 SOLENOID RECEIVER/DRIER ASSY VALVE TEV 5/8 X 5/8 X 3/8 TEE LIQUID INDICATOR 5/8 DRIER 3/8 3/8 RECEIVER 5/8 3/8 EVAPORATOR AIR CONDENSER LP SERVICE SCHRADER 1/8 PROCESS PORT INE-3-GA PHIAL 1/2 HP SERVICE SCHRADER 5/8 1/4 1/4 5/8 5/8 COMP 5/8 5//8 1/2 1/2 1/2 HP LP 3/8 1/2 EQUI TEE 1/2 X 1/2 3/8 TEE SUCTION ACCUMULATOR 5/8 X 5/8 X 1/4 TEE 1/2 1/2 X 1/2 X 1/4 TEE 5/8 X 5/8 X 3/8 TEE DH150 AX/BX INSULATION 5/8 5/8 PROCESS 5/8 PORT 5/8 X 5/8 X 1/4 TEE TEV LIQUID INDICATOR RECEIVER DRIER 3/8 5/8 3/8 3/8 1/4 3/8 AIR CONDENSER EVAPORATOR 1/8 REDUCER 3/4 X 5/8 3/4 5/8 REDUCER 1/2 X 3/8F INSULATION 7/8 X 3/4 REDUCER NRV 3/8 LP MOUNTED IN ELEC BOX HEAT EXCHANGER 3/8 5/8 X 5/8 X 1/4 TEE 7/8 X 7/8 X 5/8 TEE HP SERVICE FIT IN 5 O'CLOCK POS'N ON HORIZONTAL PIPE REDUCER 3/4 X 5/8 COMP 7/8 LP SERVICE 150 min REDUCER 1 1/8 X 7/8 IN 2 POS'NS HP MOUNTED IN ELEC BOX 5/8 7/8 TEV PHIAL HP LP ELBOW 7/8 SUCTION ACCUMULATOR 7/8 DH300BL Page 27 DRG.No. D538050 ISSUE 1. 12:02:07 3/8 EQUAL TEE RECEIVER 5/8 X 5/8 X 3/8 TEE CAPILLARY 1/4 DIA 21 SWG X 300 (12") 3/8 EQUAL TEE REDUCER 3/8 X 1/4 3/8 TEV 5/8 3/8 5/8 X 5/8 X 3/8 TEE 5/8 CRIMP & BRAZE 5/8 PORT 3/8 NRV 3/8 PROCESS EDCM PHIAL DRIP TRAY HEATER LIQUID INDICATOR RECEIVER DRIER 3/8 3/8 3/8 AIR CONDENSER 3/8 1/4 3/8 5/8 3/8 EVAPORATOR REDUCER 1/2 X 3/8F 1/8 3/4 3/4 3/4 3/4 3/4 3/4 REVERSING VALVE INSULATION COIL 7/8 X 3/4 REDUCER LP MOUNTED IN ELEC BOX 1/2 3/8 REDUCER 5/8 X 1/2 NRV HEAT EXCHANGER 7/8 X 7/8 X 5/8 TEE 5/8 X 5/8 X 1/4 TEE 3/8 HP SERVICE ELBOW 7/8 FIT IN 5 O CLOCK POS'N ON HORIZONTAL PIPE 150 min REDUCER 1 1/8 X 7/8 IN 2 POS'NS HP MOUNTED IN ELEC BOX 5/8 7/8 TEV PHIAL HP LP REDUCER 3/4 X 5/8 COMP LP SERVICE 7/8 SUCTION ACCUMULATOR DRG.No. D363850 ISSUE 3. 31:01:07 7/8 DH300BLY CAPILLARY 5/16 DIA 21 SWG X 300mm (12") 5/8 X 5/8 X 5/8 TEE 5/8 X 5/8 X 1/4 TEE 5/8 1/4 PROCESS PORT 5/8 TEV 5/8 5/8 5/8 CRIMP & BRAZE EDCM PHIAL 7/8 7/8 LIQUID INDICATOR DRIP TRAY HEATER DRIER RECEIVER SD-490-50 5/8 5/8 7/8 5/8 NRV 5/8 5/8 1/2 NRV 7/8 X 7/8 X 5/8 TEE AIR CONDENSER 5/8 FIT IN 5 0 CLOCK POSITION ON HORIZONTAL PIPE. 1 3/8 1 3/8 7/8 7/8 TEV PHIAL REDUCER 1 3/8M - 7/8F INSULATION REDUCER 1 3/8F -1 5/8M REVERSING VALVE 1 3/8 5/8 HEAT EXCHANGER DRILL HOLE (REMOVE SWARF) COIL NRV 5/8 REDUCER REDUCER 3/4M - 1 1/8F HP 1 3/8 3/4 HP SERVICE SCHRADER 1 5/8M -1 3/8F 1 3/8 HP & LP SWITCH.MOUNTED COMP 1 3/8 IN ELECTRIC BOX. SUCTION ACCUMULATOR LP LP SERVICE SCHRADER 1 3/8 5/8 7/8 EVAPORATOR 1 3/8 SD-3048-50 DH600BY Page 28 DRG.No. D64204956 ISSUE 12. 28:07:10 GREY ORANGE PINK RED VIOLET WHITE P R V W DH150AX DH150AXF 7A 10A CONTROL W/R R/O R/BR R/B R/BL O/BL G/Y 1A 1A CONDENSATE PUMP WHITE/RED RED/ORANGE RED/BROWN RED/BLUE RED/BLACK ORANGE/BLACK GREEN/YELLOW GREY/BLUE HUMIDISTAT HIGH AIR LIMIT STAT 2 1 1 2 H(N/C) 1 2 PUMP FUSE 1 (N/O) 3 6 DRAWING CHANGE HOURS RUN METER ADDED FAN CHANGES WAS SD127102 NOW SD127106 MULTI SPEED EDITION 7 PJ MW APPD 1206 1123 C/N 07:03:07 03:12:07 DATE CALOREX HEAT PUMPS LTD U.C.C. c CRIMP TOGETHER R FINISH MATERIAL L CAP OFF NOT USED WIRES EARTH BOLT ON FAN DIAPHRAM CAP FAN BR 2.5 G/Y 1,5 G/Y 1,5 G/Y 1,5 FAN FLYING LEAD SOFT START (IF FITTED) G/Y 1,5 A1 W/R 0.5 B 1.0 3 B 4 CONTACTOR 1 6 T.B. A2 6 5 14 13 NO EARTH BOLT HOLES TO BS 4500 E12 INSPECTION LEVEL TOLERANCE UNLESS SPECIFIED R R BR 1,0 G/Y 1,5 W 0,5 R DIMS L N CAP RUN B 2.5 G/Y 1,5 INTERLOCK TITLE GR 0.5 C L LP SWITCH C H HP SWITCH 4 1 DEFROST THERMOSTAT 3 2 CONDENSATE PUMP FUSE R 1.0 WIRING AND CIRCUIT DIAGRAM DH150AX EARTH CHASSIS RELAY & HARD START CAPACITOR SD64073150 (IF FITTED) SWITCH BRACKET OUTLINE CAP FAN TIMER BR CONTROL FUSE SHT No. --- CONT' DRG No. 1 R/O 0,5 1 2 1 RED GREEN WHITE D205951 JAC DRAWN APPROVED CAP OFF R 0,5 YELLOW B 1.0 DATE 14:1:91 W 1.0 BR 1,0 NOT REQD. (IF FITTED) CONDENSATE PUMP HUMIDISTAT BLUE BLACK CYCLE 1 CONTINUOUS 2 MODE SWITCH GREEN/YELLOW B BR O 0.5 W 1,0 3 HIGH AIR THERMOSTAT R/O 1.0 O 0.5 WIRING FOR 'F' VERSION FAN FIG 1 SA088851 (S+P) FAN CONNECTIONS PRE DCR1053 R BR B BL G/Y N G/Y 1,5 G/Y 1,5 B 0.5 GR 0,5 2 1 FAN MOTOR F VERSION 14/5/08 27/11/08 BROWN BLUE BLACK WHITE G/Y BLUE RED G/Y 1,5 BL 2.5 P 2.5 R 2.5 FAN CAP FLYING LEAD SD127106 FAN MOTOR R S C COMPRESSOR R 1.0 BR 2.5 TO HOURS RUN METER ISS KW CONDENSATE PUMP WIRING ALTERED 8 1232 S+P FAN YELLOW WIRE WAS BROWN 9 25/01/10 FAN 2 1 3 ON/OFF SWITCH SOLENOID COIL NTS SCALE R 0,5 PJ 23/02/10 17/06/10 DEFROST (WHITE) GR 0.5 FAULT (AMBER) ELECTRIC BOX ASSY D205951 R 0,5 KW 1370 10 PJ KW N MAINS (RED) GR/B 0,5 W/R 0.5 B 1,0 DRG No. TO DEFROST STAT TO CONTACTOR A2 (N) 1287 1441 CONTACTOR CHANGED, COMPONENT FUNCTIONS ADDED TO CCT SD127106 FAN LEADS CLARIFIED, CONNECTIONS TO TERM BLOCK ALTERED, CHASSIS EARTH ADDED 1476 DEFROST LAMP DEFROST VALVE 2 TEMP FALLING MAKES 1-3 ON 11 4 (N/C) C R FAN MOTOR FAN CAP' S COMPRESSOR RELAY/HARD START CAP (IF FITTED) SOFT START (IF FITTED) CONDENSATE PUMP (IF FITTED) (COM) DEFROST THERMOSTAT 1 CAP RUN MAINS LAMP CONTROL SWITCH 3 C(COM) C(COM) SWITCH COLOURS CHANGED FOR CLARITY CONTROL FUSE LP SWITCH BREAKS ON PRESSURE FALLING (N/C)L HP SWITCH BREAKS ON PRESSURE RISING A2 A1 HOURS RUN METER 2(NO) 1 DELAY TIMER 6(NO) CONTACTOR 5 CIRCUIT DIAGRAM DE-ENERGISED STATE WITH REFRIGERATION CIRCUIT FULLY CHARGED FAN MODE SWITCH CONSOLE ASSY W 1,0 B 0,5 GR/B WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CCT DIAGRAM,THEY ARE SHOWN IN PUMP STARTER OR FLOW SWITCH (DHW ONLY) IF IN DOUBT ASK G/Y 1,5 12 L BROWN FUSE VALUES BLUE B 0.5 B 2.5 B 0.5 O BR GR INTERLOCK CYCLE CONT FAULT LAMP B BR G/Y BR 2.5 R/O 1.0 P 0.5 SEE FIG 1 FOR 'F' VERSION BR 2.5 R 2.5 B 0.5 B 0.5 B 1.0 B 1.0 BL 2.5 B 2.5 B 1.0 B 2.5 B 0.5 B 2.5 W 1.0 W/R 0,5 R B B 2.5 W 0,5 HOURS RUN BR 2.5 B 0.5 W/BL 0.5 BR 2.5 BR 1,0 R/O 0,5 METER W 1,0 GREEN/RED BR 1,0 G/R PUMP LEAD BLACK W/R 0.5 GR 0.5 V 0,5 P 2.5 W/BL 0.5 B 0.5 V 0,5 Page 29 GR/B 0,5 R/BL 0,5 R/BL 0,5 P 0.5 BL 16.0 WIRING DIAGRAMS FAN CAP GR/B G/Y O/BL R/BL R/B R/BR R/O W/R GREY ORANGE PINK RED VIOLET WHITE GR O P R V W 3A DH150BXF 3A 3A 3A 3A 1A 1A PUMP (F4) 10A 7A FAN (F5) WHITE/RED RED/ORANGE RED/BROWN RED/BLUE RED/BLACK ORANGE/BLACK COM L2 L1 11 2 1 1 1 2 1 1 (COM) 3 PHASE ROTATION ADDED, EXTENSIVE CHANGES HOURS RUN METER ADDED SD127102 FAN REPLACED WITH SD127106 MULTI SPEED FANS 12 11 10 DRAWING CHANGE ON/OFF SWITCH TERMINAL No'S CHANGED IGH C/N 908 APPD GSM GSM 1112 1053 18/10/06 DATE 28:10:96 29:9:03 CALOREX HEAT PUMPS LTD U.C.C. c R FINISH MATERIAL CAP FAN 3 EARTH 5 6 A2 4 R 2.5 INSPECTION LEVEL HOLES TO BS 4500 E12 TOLERANCE UNLESS SPECIFIED SWITCH BRACKET OUTLINE EARTH BOLT R 1.0 R 1.0 R/BL 1,0 G/Y 1,5 CHASSIS T.B. 2 A1 CONTACTOR INTERLOCK CAP FAN FLYING LEADS 430mm LONG 14 13 NO DIMS BL 2.5 TITLE N R 2.5 P 2.5 L2 B 2.5 L3 GR 0.5 GR 0.5 DH150BX / DHW150BX --- BLUE BLACK RED GREEN WHITE CONT' DRAWN 1 2 MODE SWITCH CYCLE 1 CONTINUOUS 1 APPROVED (IF FITTED) CONDENSATE PUMP PUMP LEAD D206050 JAC 2 HUMIDISTAT CAP OFF NOT REQD GREEN/YELLOW B BR O 0.5 W 0.5 R/O 0,5 YELLOW 3 HIGH AIR THERMOSTAT R 0.5 O 0.5 WIRING FOR 'F' VERSION FAN FIG 1 DRG No. 1 SHT No. C L C LP SWITCH R 0.5 W 0.5 5 H HP SWITCH B 0.5 WIRING AND CIRCUIT DIAGRAM L1 4 3 DEFROST THERMOSTAT 1 2 4 BL 1,0 14:1:91 DATE R 0,5 R/BL 0.5 NTS SCALE FAN CAP ISS FAN CHANGES. 'F' VERSION WAS 7A L B G/Y 1,5 B 0.5 R 2.5 1 FAN MOTOR F VERSION 7 BR B BL G/Y CRIMP TOGETHER R Y FAN CONNECTIONS PRE DCR1053 FAN G/Y 1,5 G/Y 1,5 G/Y 1,5 G/Y 1,5 G/Y 1,5 EARTH BOLT ON FAN DIAPHRAM WIRES NOT USED CAP OFF FAN FLYING LEAD G/Y 1,5 GR 0.5 B 0.5 R 2.5 R 0.5 P 0.5 B 2.5 3 SA088851 (S+P) 07:03:07 03:12:07 14/5/08 23/9/08 27/11/08 N 14 P 2.5 2 R1 R 0,5 8 MW 1123 KW KW PJ 1232 1206 1232/2 KW 29/04/09 11 R 1.0 1 B 9 6 3 R 0,5 FAN CAP FLYING LEAD SPEC. ADDED 'F' FAN WIRING AND RELAY NUMBERING CLARIFIED 13 1287 23/02/10 25/01/10 BROWN BLUE BLACK WHITE G/Y BLUE RED G/Y 1,5 B 2.5 P 2.5 R 2.5 W/R 0.5 SOLENOID COIL FAN CAP FLYING LEAD FAN MOTOR SD127106 W V U COMPRESSOR SOFT START (IF FITTED) 2 1 3 ON/OFF SWITCH BR 1,0 L2 L3 PHASE ROTATION RELAY BL 1.0 B 2.5 A 7 4 1 TO RELAY (4) 9 S+P FAN YELLOW WIRE WAS BROWN 14 AJB PJ DEFROST (WHITE) GR 0.5 R 0.5 L1 B 2.5 W/R 0.5 BR 1.0 R/BL 1,0 ELECTRIC BOX ASSY D206050 G/Y 1,5 1318 1441 1370 SD127106 FAN LEADS CLARIFIED, CONNECTIONS TO TERM BLOCK ALTERED, CHASSIS EARTH ADDED PJ DEFROST LAMP B 0.5 R 0.5 TIMER DRG No. B 0.5 CHANGE WIRE DETAIL AS PER DCR 2 TEMP FALLING MAKES 1-3 ON B RELAY 4 (N/O) N P 0.5 FAULT (AMBER) GR/B 0,5 B 0.5 IF IN DOUBT ASK TO DEFROST STAT 15 FAN CAP' DEFROST VALVE CONDENSATE PUMP (IF FITTED) (N/O) U FAN MOTOR CONTACTOR & PHASE ROTATION CHANGED, COMPONENT FUNCTIONS ADDED TO CCT 1 4 A (COM) 7 V W COMPRESSOR SOFT START (IF FITTED) DELAY TIMER DEFROST THERMOSTAT (N/C) 2 MAINS LAMP PUMP FUSE A2 A1 HOURS RUN METER 2(NO) 1 HIGH AIR LIMIT STAT CONTROL SWITCH 3 C (COM) H (N/O) C (COM) H (N/C) 2 HUMIDISTAT N/O PHASE ROTATION RELAY 4(NO) 3 17 LP SWITCH BREAKS TO 'H' ON PRESSURE FALLING (N/C) L PRESSURE RISING HP SWITCH BREAKS TO 'L' ON (N/O) L FAN FUSE 14 L3 3 6(NO) CONTACTOR 5 CIRCUIT DIAGRAM MAINS (RED) W/R 0.5 B 0.5 CONSOLE ASSY HOURS RUN METER W 0,5 GREEN/YELLOW 16 L1 L2 L3 PUMP STARTER OR FLOW SWITCH (DHW ONLY) R 0.5 GREY/BLUE DE-ENERGISED STATE WITH REFRIGERATION CIRCUIT FULLY CHARGED INTERLOCK B 0.5 GREEN/RED WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CCT DIAGRAM,THEY ARE SHOWN IN 3A DH150BX PHASE/R PHASE/R PHASE/R (F1) (F2) (F3) FUSE VALUES G/R FAULT LAMP CYCLE CONT B 0.5 B 0.5 BROWN FAN MODE SWITCH B 0.5 B 0.5 B 0.5 BR 1.0 R 0.5 SEE FIG 1 FOR 'F' VERSION P 2.5 P 2.5 P 0.5 R 0.5 W/R 0.5 G/Y 1.5 BR 1.0 BL 2.5 B 0.5 B 2.5 B 0.5 BLUE BL 1,0 BLACK W/R 0.5 B 0.5 W/BL 0.5 BR W/BL 0.5 B 0.5 V 0,5 B B 0,5 R 1.0 BR V 0,5 B 0.5 P 0.5 BR 1.0 BR 1.0 BR 1.0 GR/B 0,5 Page 30 R/O 0,5 R/BL 0,5 W 0,5 R/BL 0,5 BL TO CONTACTOR A2 (N) LABEL D207650 ISSUE 17 3A DH150BXF 3A 3A 3A 3A 1A 1A 7A 10A COM L2 L1 11 (F2) (F1) L1 L2 L3 C(COM) 9 (COM) (N/O) 6 2 CONTROL SWITCH 1 2 1 B (COM) 7 (N/O) 3 4 CONDENSATE PUMP 1 2 CONTACTOR & PHASE ROTATION CHANGED, COMPONENT FUNCTIONS ADDED TO CCT SD127106 FAN LEADS CLARIFIED, CONNECTIONS TO TERM BLOCK ALTERED UNUSED FAN WIRES CAPPED OFF S+P FAN YELLOW WIRE WAS BROWN 6 5 4 3 1370 C/N APPD KW KW PJ DATE 27/11/08 4/12/08 28/01/10 23/02/10 18/06/10 R 2,5 6 1 T.B. 6 5 14 NO 13 G/Y 1,5 BL 0.5 G/Y 1,5 G/Y 1,5 G/Y 1,5 BROWN R FINISH G/Y 1,5 G/Y 1,5 G/Y 1,5 G/Y 1,5 B 2,5 P 2,5 ISOLATOR 56 34 12 BL 2,5 G/Y 1,5 N L1 BL 0.5 L3 MAINS IN BOX BL 0.5 L2 INSPECTION LEVEL HOLES TO BS 4500 E12 O 0.5 TIMER W/R 0.5 TOLERANCE UNLESS SPECIFIED B 2,5 P 2,5 R 2,5 R 1.0 R 1.0 4 CONTACTOR BL 2,5 BLUE MATERIAL WIRES NOT USED CAP OFF GR 0,5 BL 0,5 2 3 B 1.5 R/BL 0.5 EARTH BOLT ON CALOREX HEAT PUMPS LTD U.C.C. c R 2.5 FAN CAP FLYING LEAD G/Y 1,5 14 1 A2 W/R 0.5 BLACK WHITE G/Y BLUE RED FAN FLYING LEAD B 1,5 P 1,5 11 ROTATION RELAY PHASE W/R 0.5 W/R 0.5 A1 R/BR 0.5 DIMS G/Y 1,5 3 6 9 B 1 4 7 A RELAY No 3 FAN CAP' TITLE BL 2,5 4 1 L C LP SWITCH C GR/B 0,5 DH150BX(F) WIRING AND CIRCUIT DIAGRAM H HP SWITCH BL 0.5 DEFROST THERMOSTAT 3 2 R/B 0,5 (F4) W/R 0,5 O 0.5 3 6 9 B 1 4 7 A RELAY No 1 R/O 1,0 R/BL 0.5 BL 0.5 BL 0,5 CONT' --- CYCLE 1 CONTINUOUS R 0.5 2 GR GR BL 0.5 RED GREEN WHITE D582250 DRAWN APPROVED WIRES 6 NOT USED CAP OFF R 0,5 R/BL 0.5 YELLOW BLUE 3 B 9 6 3 PUMP RUN DATE R 0,5 BR 0.5 NTS SCALE TERM' BLOCK RED LINK 0,5 FLOAT SWITCH BLACK GREEN/YELLOW CONDENSATE PUMP FLOAT SWITCH HIGH LEVEL A 7 4 1 RELAY No2 D582250 HUMIDISTAT 1 MODE SWITCH R/B 0,5 BR 0,5 O 0.5 O 0.5 W 1,0 R/BL 0.5 WIRING FOR 'F' VERSION FAN FIG 1 DRG No. 1 SHT No. (F5) O 0.5 DRG No. TO RELAY 3 (4) 1287 1287-2 PJ KW SD127106 FAN MOTOR W V R 1,5 BLACK SLEEVE P 0.5 L2 L3 BL 2,5 B 2.5 SA088851 (S+P) 1441 1476 DEFROST LAMP BASE PLATE G/Y 1,5 U COMPRESSOR 2 1 3 ON/OFF SWITCH BR 1,0 R 0.5 R 0.5 L1 B 2.5 ELECTRIC BOX ASSY FAN MOTOR F VERSION DRAWING CHANGE A TEMP FALLING MAKES 1-3 ON DEFROST VALVE B 4 (N/O) FAN MOTOR CAP' FAN PUMP RUN FLOAT SWITCH SWITCH AND LAMP CHANGES MAINS LAMP (COM) W U DEFROST (WHITE) GR 0,5 SOLENOID COIL IF IN DOUBT ASK R 0,5 7 (F4) 1 RELAY No 3 V COMPRESSOR HIGH LEVEL FLOAT SWITCH (COM) 7 DELAY TIMER DEFROST THERMOSTAT (N/C) B A RELAY No 2 A RELAY No 1 (N/C) 1 PHASE ROTATION RELAY A2 5 4 (N/O) 2 (N/O) A1 HOURS RUN METER CONTACTOR 6 (N/O) 3 1 N O 0.5 FAULT (AMBER) METER HOURS RUN G/Y 1,5 PUMP FUSE 3 HUMIDISTAT (N/C)L (F5) FAN FUSE H(N/C) N/O C(COM) 14 L3 (F3) ISOLATOR CIRCUIT DIAGRAM DE-ENERGISED STATE WITH REFRIGERATION CIRCUIT FULLY CHARGED MAINS (RED) R 2.5 CONSOLE ASSY UNCONTROLLED WHEN PRINTED R 0,5 TO H.R.M ISS WHITE/RED RED/ORANGE RED/BROWN RED/BLUE RED/BLACK ORANGE/BLACK WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CCT DIAGRAM,THEY ARE SHOWN IN 3A DH150BX PHASE/R PHASE/R PHASE/R (F1) (F2) (F3) FAN (F5) W/R GREEN/YELLOW G/Y PINK PUMP (F4) R/O GREY/BLUE GR/B ORANGE FUSE VALUES R/BR GREEN/RED G/R GREY R/B P R/BL O ORN/BLK WHITE BL 2,5 BL 0,5 VIOLET BL 2,5 BL 0,5 RED BR GR HP SWITCH B W BREAKS ON R/O 1,0 SEE FIG 1 FOR 'F' VERSION G/Y V FAULT LAMP R 0.5 R 2.5 R 2.5 R 1.5 R 2.5 R FAN MODE SWITCH BL 0.5 B 0.5 BR 1.0 P 2.5 (F1) R 0.5 R 2.5 (F2) P 0.5 B 2.5 (F3) B 0.5 BR 0.5 BR 0,5 BROWN BR 1.0 P 2.5 P 2.5 P 1.5 R 2.5 R/BR 0.5 BLUE PRESSURE RISING LP SWITCH BREAKS ON PRESSURE FALLING CYCLE CONTINUOUS BL 0.5 R 1.0 BL 0,5 BLACK R 1.0 O/R 0,5 BR GR 0,5 V 0,5 BL 0,5 BL 0,5 0/R 0,5 R 0,5 B GR 0,5 W/R 0,5 BL 0,5 V 0,5 W 1,0 BR 1,0 G/R 0,5 G/R 0,5 GR GR R 0,5 BL LABEL D582251 ISS 7 BL 0,5 G/Y 1,5 Page 31 TO CONDENSATE PUMP FAN CAP R/BL 0.5 GR/B 0,5 RED /BROWN R/BR PUMP CONTROL MCB 2.0 AMPS 2.5 AMPS 2.63 AMPS 'F'FAN MCB CONTROL 2.04 AMPS FAN MCB X 2(N/C) L3 L2 L1 11(COM) 4(N/C) 2(N/C) 3 1 5 CONTACTORS 1 3 2(N/O) 4(N/O) 6(N/O) A1 2(N/O) 4(N/O) 6(N/O) A1 1 2 AIR LIMIT STAT C L (COM) (N/C) CLOSE ON BELOW TEMP DEFROST SETTING 3 STAT CYCLE V ISS 1 AS DRAWN DRAWING CHANGE C/N 1399 6(N/C) 5 A2 1 3 5 A2 HUMIDISTAT CLOSE ON ABOVE HUMIDITY SETTING SELECT SWITCH C TRIPPING CURRENT & SETTING VALUE FOR FAN MCB WERE 1.73A & 1.4A RESPECTIVELY. C/CASE HEATER NOW SEPARATE FROM COMPRESSOR. 2(N/C) 1 6 7 8 9 L(N/C) C(COM) H(N/C) CONT 2 4(N/C) 3 MCB's 6(N/C) 5 H(N/O) L(N/O) MAINS LIGHT X 3 (N/C) STANDBY C(COM) 54 53 54 53 14(N/O) CONDENSATE PUMP/ CONTROL BOX MCB 1 2(N/C) 1442 LIGHT IF FITTED SOFT START THERMAL O/LOAD AND (BREAKS TO 'H' ON PRESSURE FALLI NG) LP SWITCH (BREAKS TO 'L' ON PRESSURE RISING) HP SWITCH FAN MCB AUX NC COMPRESSOR MCB AUX NC RUN (N/O) 2 (COM) 1 RELAY PHASE ROTATION STANDBY SWITCH X 4(N/C) 6(N/C) 1 X 3 5 CONTROL MCB L1 COMPRESSOR MCB CHANGED. MARKINGS NOW FOR CHINT L2 FAULT LIGHT 3 L3 INTERLOCK INTERLOCK TERMINALS TERMINALS CONDENSATE PUMP/ CONTROL BOX ELECTRICAL CIRCUIT DIAGRAM U APPD PJ DH FAN COMPRESSOR W DELAY TIMER LIGHT DEFROST 21 N DATE 07:02:07 30/10/09 19:04:10 22 WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CIRCUIT DIAGRAM ABOVE CONDITIONS APPLY 1 3 STANDBY GR 0.5 O 0,5 CALOREX HEAT PUMPS LTD V 0,5 U.C.C. c 2 RUN FAULT MAINS DEFROST BL 0,5 CONSOLE OUTLINE GR/B 0,5 ALL OTHER CONTACTS SHOWN IN DE-ENERGISED STATE BUT WITH REFRIGERATION CIRCUIT FULLY CHARGED W/BL 0,5 MCB CONTACTS / MCB ALARM CONTACTS / MCB AUX CONTACTS SHOWN WITH CIRCUIT BREAKER MANUALLY SWITCHED TO THE ON CONDITION GREEN/RED RED/BLACK R/BL G/R WHITE/RED W/R GREEN/YELLOW WHITE/BLACK W/BL RED/BLUE BROWN BR R/B BLACK BL ORANGE/RED GREY/BLUE GR/B G/Y GREY GR 0/R WHITE VIOLET W V VALUE 20.16 AMPS COMPRESSOR MCB R HUMIDISTAT G/Y 1,5 1 FINISH MATERIAL W 0,5 L1 N L2 4 INCOMING SUPPLY 3 2 EARTH TO BASE PLATE O 0,5 ORANGE R/BR 0,5 O/BL 0,5 O G/Y 1,5 G/Y 1.5 G/Y 1.5 DEVICE SETTING C 1 L3 5 7 INTERLOCK 6 V 0,5 9 SOFT START 8 AIR LIMIT STAT 3 W/R 0,5 2 V 0,5 W/R 0,5 W/BL 0,5 FAN CYCLE SWITCH FAN CONT V 0,5 W/BL 0,5 G/R 0,5 DESCRIPTION C L GR 0,5 DEFROST STAT 10 11 GR 0,5 1 3 5 CONTROL MCB 2 4 6 TIMER 54 98 97 53 5 3 COMP MCB 4 6 1 2 INSPECTION LEVEL HOLES TO BS 4500 E12 TOLERANCE UNLESS SPECIFIED BR 1.5 BL 1.5 BL 1.5 BR 0.5 R 0.5 BR 1.5 P 0.5 G/Y 1.5 BL 0,5 BL 0,5 BL 0,5 R 2.5 R 2.5 P 2.5 P 2.5 B 2.5 B 2.5 O 0,5 O 0,5 W/BL 0,5 V 0,5 BR 1,5 BL 0,5 BL 0,5 R 2,5 R 2,5 P 2,5 P 2,5 B 2,5 B 2,5 B 0,5 AUX GR/B 0.5 BLUE W/R 0.5 54 98 97 53 1 2 3 5 FAN MCB 4 6 R 2,5 DIMS 1 2 TITLE CONDENSATE PUMP/ CONTROL BOX (IF FITTED) W 0,5 V 0,5 PINK GR 1,0 V 0,5 RED COMP AUX (NC) HEATER(S) R 2.5 P 2.5 AUX W 1,0 BL 1,5 GR/B 0,5 R 2,5 R 2,5 P 2,5 P 2,5 B 2,5 B 2,5 B 2.5 GR/B 0,5 R 2,5 R 2,5 R 2,5 P 2,5 P 2,5 B 2,5 B 2,5 0 1,0 BR 1,5 PUMP CONTROL MCB BR 1.5 G/Y 1,5 B R 0,5 R/BR 0,5 11 BUTT--- DH300BL(F) BUTT--- A1 3 A2 5 2 V 4 6 W / CONT' 22 1 A1 3 A2 5 07:02:07 DATE 6 4 2 CONTACTOR D537850 PJ W 1.0 LOW PRESSURE SWITCH HIGH PRESSURE SWITCH D537850 APPROVED EARTH 21 L H C H L C BL 0,5 W 0.5 DRAWN COMPRESSOR U W 0,5 DRG No. CONTACTOR 1 DRG No. 1 SHT No. LOOM SUMP HEATER 14 L3 WIRING DIAGRAM PUMP FLYING LEAD L2 RELAY ROTATION PHASE L1 P 0,5 BL 0,5 B 0,5 P BR 0,5 BR 1.5 BR 1.5 R 2.5 R 2,5 V 0,5 G/R 0,5 R BL 1.5 BL 1.5 BR 1,5 1.COLOUR CODE P 2,5 IF IN DOUBT ASK G/Y 1.5 NOTES GR 1.0 P 2.5 W/R 0,5 B 2.5 B 2,5 GR 1.0 W 1.0 BR 1,5 G/Y 1,5 W/BL 0.5 O 1.0 O 1.0 Page 32 W 0.5 LOOM N.T.S SCALE FAN 22 21 LABEL D537950 ISSUE 3 BR 0,5 BR 0.5 RED/BLUE RED/BROWN GREEN/RED 0/R R/B R/BR G/R 2.0 AMPS 2(N/C) 6(N/C) 4(N/C) L1 L3 L2 COMPRESSOR MCB AUX NC THERMAL 5 CONTACTOR O/LOADS REMOVED. MCBs REPLACE TBs 15-22 + FUSES. PHASE ROTATION RELAY ADDED. O/LOAD SETTING & FUSE TABLE DELETED. ISS 2 DRAWING CHANGE PUMPDOWN/TEXAS REMOVED O/LOAD SET ALTERED. FUSE WAS 1A T.B. No22 INTERLOCK CONNECTIONS 6-7 WAS 8-9; SOFT START CONNECTION 8-9 WAS 6-7. 4 3 C/N 921 929 1149 1243/8 1243/10 APPD MJH/GSM BD PJ AJB DATE 14:05:96 13:06:05 12:02:07 08/09/08 05/03/09 REMOVE EDCM FROM ELEC PANEL - REPLACE WITH DEFROST STAT MOUNTED ON RH REAR CORENR PILLAR 5 AJB 19:04:10 SEPARATE CRANK CASE HEATER FROM COMPRESSOR AS D315854 FAN 6 2(N/O) 4(N/O) 6(N/O) 30/10/09 CONTACTORS 1 3 U COMPRESSOR W PJ 2(N/C) 1 V DELAY TIMER DEFROST LIGHT DH 4(N/C) 3 A1 2(N/O) 4(N/O) DEFROST STAT REVERSING VALVE 2 1442 6(N/C) 5 A2 1 6(N/O) A1 4 1399 2(N/C) 1 3 5 A2 1 2 AIR LIMIT STAT TEMP SETTING 3 HUMIDITY SETTING HUMIDISTAT CLOSE ON BELOW CLOSE ON ABOVE CYCLE 3 TRIPPING CURRENT & SETTING VALUE FOR FAN MCB WERE 1.73A & 1.4A RESPECTIVELY 4(N/C) MCB's 6(N/C) 3 6 7 8 9 L(N/C) SWITCH C 1 TEMP FALLING MAKES 1 TO 3 ON COMPRESSOR MCB CHANGED. MARKINGS NOW FOR CHINT FITTED LIGHT IF H(N/O) C(COM) H(N/C) CONT SELECT 3 (N/C) STANDBY C(COM) 54 53 54 53 14(N/O) 5 SOFT START O/LOAD AND L(N/O) (BREAKS TO 'H' ON PRESSURE FALLING) LP SWITCH (BREAKS TO 'L' ON PRESSURE RISI NG) HP SWITCH FAN MCB AUX NC 14 (COM) 1 11 RUN (N/O) 2 STANDBY SWITCH X X X X MAINS LIGHT N 8 1 5 3 RELAY PHASE ROTATION 11(COM) CONTROL BOX (COM) CONTROL MCB FAULT LIGHT INTERLOCK INTERLOCK TERMINALS TERMINALS CONDENSATE PUMP/ (N/C) CONDENSATE PUMP/ CONTROL BOX MCB 1 2(N/C) ELECTRICAL CIRCUIT DIAGRAM (N/O) L1 21 22 L2 BL 0,5 1 3 STANDBY GR 0.5 O 0,5 CALOREX HEAT PUMPS LTD U.C.C. c 2 RUN FAULT MAINS DEFROST BL 0,5 CONSOLE OUTLINE GR/B 0,5 WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CIRCUIT DIAGRAM ABOVE CONDITIONS APPLY R/BR 0,5 ALL OTHER CONTACTS SHOWN IN DE-ENERGISED STATE BUT WITH REFRIGERATION CIRCUIT FULLY CHARGED COMP AUX (NC) HEATER(S) 7 L3 ORANGE/RED G/Y PUMP CONTROL MCB 2.5 AMPS 2.63 AMPS 'F'FAN MCB CONTROL 2.04 AMPS 20.16 AMPS FAN MCB COMPRESSOR MCB W/BL 0,5 MCB CONTACTS / MCB ALARM CONTACTS / MCB AUX CONTACTS SHOWN WITH CIRCUIT BREAKER MANUALLY SWITCHED TO THE ON CONDITION RED/BLACK GREEN/YELLOW R/BL WHITE/BLACK BROWN WHITE/RED BR W/R BLACK W/BL GREY GREY/BLUE BL VIOLET V GR/B WHITE W GR BLUE ORANGE O R HUMIDISTAT G/Y 1,5 G/Y 1.5 O/BL 0,5 O 0,5 G/Y 1,5 1 FINISH MATERIAL W 0,5 3 L1 2 N L2 4 INCOMING SUPPLY EARTH TO BASE PLATE G/Y 1.5 B C L3 5 7 INTERLOCK 6 3 9 LOOM SOFT START 8 AIR LIMIT 1 STAT 2 W/R 0,5 W/R 0,5 V 0,5 R/O 0,5 FAN CYCLE SWITCH FAN CONT V 0,5 10 W/BL 0,5 G/R 0,5 BL 0,5 BL 0,5 11 REVERSING VALVE BL 1,5 BL 1,5 DEVICE SETTING VALUE 12 13 V 0,5 1 3 5 CONTROL MCB 2 4 6 HOLES TO BS 4500 E12 INSPECTION LEVEL TOLERANCE UNLESS SPECIFIED BR 1,5 BL 1,5 BL 1,5 BR 0,5 BR 1,5 R 0,5 P 0,5 G/Y 1.5 BL 0,5 BL 0,5 BL 0,5 R 2.5 R 2.5 P 2.5 P 2.5 B 2.5 B 2.5 O 0,5 O 0,5 W/BL 0,5 V 0,5 BR 1,5 BL 0,5 BL 0,5 R 2,5 R 2,5 P 2,5 P 2,5 B 2,5 B 2,5 B 0,5 DESCRIPTION TIMER 54 98 97 53 1 2 R 2,5 GR 0,5 BL 1,5 BL 1,5 AUX GR/B 0,5 PINK W/R 0.5 3 5 COMP MCB 4 6 R/O 0.5 54 98 97 53 1 2 1 3 DIMS TITLE 2 4 5 L3 BUTT--- DH300BLY(F) BUTT--- B 0,5 SUMP HEATER R/BR 0,5 14 BR 0,5 11 RELAY ROTATION WIRING DIAGRAM PUMP FLYING LEAD L2 P 0,5 PHASE L1 W/BL 0.5 GR 0.5 GR 0.5 3 DEFROST CONTROL STAT FAN MCB 4 6 CONDENSATE PUMP/ CONTROL BOX (IF FITTED) P 2,5 V 0,5 RED BL 1,5 R 0,5 P W 0.5 GR 1,0 BR 1,5 AUX W 1,0 G/Y 1,5 GR/B 0,5 R 2,5 R 2,5 P 2,5 P 2,5 B 2,5 B 2,5 B 2,5 V 0,5 GR/B 0,5 R 2,5 R 2,5 R 2,5 P 2,5 P 2,5 B 2,5 B 2,5 O 1,0 R 2,5 PUMP CONTROL MCB BR 1,5 R BR 1.5 BR 1.5 DRG No. SHT No. LOOM 1 BL 1.5 BR 1.5 A1 3 A2 5 V W / W 0,5 D363450 MJH APPROVED 1 3 A2 5 07:03:95 DATE FAN 6 4 2 CONTACTOR A1 LOW PRESSURE SWITCH HIGH PRESSURE SWITCH W 1.0 L H C H L C D363450 BL 0,5 W 0.5 EARTH 22 21 DRAWN COMPRESSOR CONT' U 6 4 2 CONTACTOR 1 DRG No. R 2,5 1.COLOUR CODE BL 1.5 BL 1.5 R 2.5 P 2,5 V 0,5 G/R 0,5 BR 1,5 BL 0,5 BL 0,5 G/Y 1.5 BR 0,5 BR 0.5 IF IN DOUBT ASK GR 1.0 P 2.5 W/R 0,5 B 2.5 B 2,5 GR 1.0 W 1.0 BR 1,5 G/Y 1,5 W/BL 0.5 O 1.0 O 1.0 NOTES N.T.S SCALE LOOM 22 21 ISSUE 8 LABEL D363550 Page 33 BLACK BROWN WHITE/BLACK WHITE/RED RED/BLACK GREEN/YELLOW ORANGE/RED RED/BLUE BL BR W/BL W/R R/BL G/Y 0/R R/B 14 RUN (N/O) L1 11 L2 L3 STANDBY (N/C) L (N/C) C (COM) H (N/C) C (COM) (NO) 53 54 53 (NO) 54 3 4(N/O) 3 1 4(N/O) 2(N/O) 3 1 8 ISS REDRAWN FOR PUMPDOWN STANDBY SWITCH ADDED 9 7 PUMPDOWN/TEXAS REMOVED TEXAS PROTECTOR ADDED 10 DRAWING CHANGE VIOLET CONDENSATE PUMP WIRES ADDED PJ FAN MJH APPD 820 C/N MJH 843 MJH MJH 918 866 GSM 929 GSM CJW CJW 967 1080 1080 CIRCUIT BREAKER AUXILLARYS 55&56 WERE 51&52 PHASE ROTATION RELAY ADDED, 3~ CONTROL MCB WAS 1~ INTERLOCK & SOFT START CHANGED OVER 11 TERM BLOCK No 22 FUSE WAS 5A U W 08/09/08 12/03/10 DATE 15:04:92 06:08:92 08:04:93 14:05:96 10:10:96 28:1:99 02:12:04 13:01:05 COMPRESSOR V L3 DELAY TIMER DEFROST LIGHT AJB 13 12 FUSES & O/LOADS REPLACED WITH M.C.B.'s DEFROST STAT (N/O) REVERSING VALVE 3 1243/8 1443 14 CHANGE EDCM TO DEFROST STAT (ALIGN ISSUE & LABEL TO DO RECORD CARD) 15 CONTACTORS 6(N/O) 5 COMP MOTOR PROTECTOR AMENDED, COMP MCB VALUES CHANGED, CONTACTOR & MCB AUXILLARIES CHANGED, SUPPLY WIRES TO MCBs CHANGED FROM 2,5mm TRIP/OFF = BREAK CONTACT MCB's 6(N/O) 2(N/O) 5 A1 L1 1 1 A2 L2 4(N/O) 2(N/O) 3 4(N/O) 2(N/O) 3 TRIP/OFF = BREAK CONTACT 6(N/O) 3 CYCLE 1 2 AIR LIMIT STAT 2.0 AMPS 2.5 AMPS MAKES 1 TO 3 ON TEMP FALLING 4 (N/C) 2 5 A1 HUMIDISTAT 1 SELECT SWITCH (COM) 1 (N) 6(N/O) A2 2 1 CONT (COM) STANDBY SWITCH 1 MAINS LIGHT 2.8 AMPS N W/BL 0,5 BL 0,5 1 GR 0.5 O 0,5 3 STANDBY DEFROST FAULT MAINS CALOREX HEAT PUMPS LTD U.C.C. c 2 RUN BL 0,5 CONSOLE OUTLINE R G/Y 1.5 1 G/Y 1,5 3 L1 2 N MATERIAL FINISH L2 4 P 6.0 INCOMING SUPPLY BL 0,5 EARTH TO BASE PLATE G/Y 4,0 23.6AMPS 3.0 AMPS CONDENSATE PUMP/ CONTROL BOX (IF FITTED) 5 SOFT START THERMAL O/LOAD AND LIGHT IF FITTED TO HIGH LEVEL FLOAT SWITCH CONDENSATE PUMP (IF FITTED) 2 (N/O) LP SWITCH BREAKS TO 'H' ON H (N/O) PRESSURE FALLING HP SWITCH L (N/O) BREAKS TO 'L' ON PRESSURE RISING FAN MCB AUX COMPRESSOR MCB AUX 2(N/O) X 4(N/O) X 6(N/O) X COMPRESSOR MOTOR PROTECTOR 1 3 5 (COM) CONDENSATE PUMP/ CONTROL BOX MCB (IF FITTED) N/A 3.0 AMPS CONTROL PUMP CONTROL MCB 3.36 AMPS O 0,5 G/Y 4,0 28.37AMPS 3.62 AMPS 'F'FAN MCB BL 0,5 FAN MCB R 6.0 COMPRESSOR MCB ELECTRICAL CIRCUIT DIAGRAM PHASE ROTATION RELAY GREY/BLUE GR/B CONTROL MCB GREY GR L1 VIOLET V L2 WHITE W 16 L3 ORANGE O O/BL 0,5 BL 0,5 DESCRIPTION W 0,5 L3 5 B 6.0 7 INTERLOCK 6 2 V 0,5 W/R 0,5 R/O 0,5 R 6.0 BL 0,5 BL 0,5 9 10 11 12 13 14 15 LOOM SOFT START 8 3 W/R 0,5 FAN CYCLE AIR LIMIT 1 STAT FAN CONT SWITCH C W/BL 0,5 HUMIDISTAT O 0,5 DEVICE SETTING VALUE O 0,5 DEVICE TRIPPING CURRENT FAULT LIGHT BLUE BR 0,5 B GR/B 0,5 REVERSING VALVE 3 4 5 6 CONTROL MCB TIMER 53 54 CONDENSATE PUMP/ CONTROL BOX (IF FITTED) INSPECTION LEVEL HOLES TO BS 4500 E12 TOLERANCE UNLESS SPECIFIED PUMP FLYING LEAD 2 1 V 0,5 R 6.0 3 5 DIMS 6 4 2 COMPRESSOR MCB 1 W/R 0.5 2 4 53 W/BL 0.5 54 GR 0.5 GR 0.5 BL 0,5 BL 0,5 3 6 5 L2 11 RELAY 14 ROTATION PHASE L1 R 1.0 CRANKCASE HEATER R 1.0 L3 BUTT FLYING LEAD DH 600 BY(F) G/Y 4,0 G/Y 4,0 A1 W 0.5 W 0,5 DRG No. 3 A2 5 (V) (U) (W) L3 21 22 N/C AUX D209850 W 1.0 1 / DRG No. CONT' 1 5 U1 W2 APPROVED 14 LOOM DATE U1 W2 V1 U2 N.T.S SCALE W1 V2 MOTOR LINKS V2 13 N/O AUX W1 15:04:92 FAN U2 V1 6 4 D209850 GSM DRAWN A2 2 SWAP MOTOR WIRES V1 & W1 TO OBTAIN CORRECT ROTATION OF FANS SHT No. 3 CONTACTOR A1 LOW PRESSURE SWITCH HIGH PRESSURE SWITCH EARTH BL 0,5 L C H C FAN ROTATION COMPRESSOR TERMINALS L2 L1 6 4 2 CONTACTOR 1 R 2.5 ALL SHARP EDGES AND BURRS TO BE REMOVED COMPRESSOR MOTOR PROTECTOR BUTT WIRING DIAGRAM TITLE LOOM 4 FAN MCB 2 1 3 DEFROST CONTROL STAT 1 V 0.5 WHERE CONTACTS ARE MARKED (N/O) OR (N/C) ON CCT DIAGRAM ABOVE CONDITIONS APPLY. BL 0,5 BL 1.5 BL 1,5 PINK BL 0,5 BL 1,5 RED INTERLOCK TERMINALS INTERLOCK TERMINALS GR 0.5 BL 1.5 P 21 22 BL 0,5 BL 1.5 R B 6.0 ALL OTHER CONTACTS SHOWN IN DE-ENERGISED STATE BUT WITH REFRIGERATION CIRCUIT FULLY CHARGED. COMP AUX (NC) HEATER(S) BR 1,5 BR 1,5 G/R 0,5 V 0,5 W 0.5 W 0.5 W/BL 0,5 V 0,5 BL 0,5 BL 1,5 P 6.0 P 1.0 R 6.0 R 0.5 R 1.0 V 0,5 R 6.0 MCB CONTACTS / MCB AUX CONTACTS SHOWN WITH CCT BREAKER MANUALLY SWITCHED TO THE ON CONDITION. V 0,5 B 6.0 1.COLOUR CODE BL 1,5 GR/B 0.5 R 6.0 GR/B 0,5 P 6.0 R 2.5 B 6.0 B 1.0 BR 1,5 P 6.0 P 2.5 AUX G/Y 1,5 R 6.0 GR 1.0 B 6.0 B 2.5 P 6.0 W 1.0 AUX GR/B 0,5 P 6.0 BL 1.5 B 6.0 O 1.0 P 1.0 BR 0.5 NOTES W 0.5 V 0,5 G/R 0,5 IF IN DOUBT ASK BR 1,5 3rd ANGLE PROJECTION R 1.0 BR 1,5 B 1.0 BR 1.5 P 2.5 R 2,5 R 6.0 PUMP CONTROL MCB (IF FITTED) BR 1,5 V 0.5 W/R 0,5 P 2,5 W/BL 0.5 GR 1.0 B 2.5 B 2,5 GR 1.0 W 1.0 BR 1.5 G/Y 1,5 O 1.0 O 1.0 DO NOT SCALE PRINT G/Y 1.5 Page 34 LABEL D210050 ISSUE 16 R 0.5 17.0 SPARE PARTS 17.1 CONSOLE ASSEMBLIES 2 MAINS 3 FAULT 4 DEFROST 5 M/C ON 1 CALOREX CONSOLE ASSY DH150 ITEM No 1 2 3 4 5 PART No DESCRIPTION QTY SD041759 SD023050 SD023051 SD023052 SD084850 CONSOLE MOULDING PILOT LIGHT RED RECTANGULAR 250V PILOT LIGHT AMBER RECTANGULAR PILOT LIGHT WHITE RECTANGULAR ROCKER SWITCH ILLUMINATED RED Page 35 UNITS 1 1 1 1 1 off off off off off 2 MAINS 3 FAULT 4 DEFROST 5 RUN STANDBY 1 CONSOLE ASSY DH300/DH600 ITEM No 1 2 3 4 5 PART No DESCRIPTION QTY SD041753 SD023050 SD023051 SD023052 SD188950 CONSOLE MOULDING PILOT LIGHT RED RECTANGULAR 250V PILOT LIGHT AMBER RECTANGULAR PILOT LIGHT WHITE RECTANGULAR ROCKER SWITCH 1 POLE C/O Page 36 UNITS 1 1 1 1 1 off off off off off 17.2 SWITCH BRACKET ASSEMBLIES SWITCH BRACKET ASSEMBLY, SINGLE PHASE SA025302 3 L N ITEM PART No. DESCRIPTION 003 SD025450 TERMINAL BLOCK 4 WAY MELAMINE QUAN 1.00 UNITS off 004 SD028750 BAR CLAMP 4.00 off INTER LOCK 4 SWITCH BRACKET ASSEMBLY, THREE PHASE SA025301 DESCRIPTION SD025450 SD025550 TERMINAL BLOCK 4 WAY MELAMINE TERMINAL BLOCK 2 WAY MELAMINE 1.00 1.00 off off 005 SD028750 BAR CLAMP 4.00 off LOCK INTER N L3 L2 PART No. 003 004 4 3 L1 ITEM 5 Page 37 QUAN UNITS 17.3 ELECTRIC BOX ASSEMBLIES ELECTRIC BOX ASSY DH150AX(F) (230V ~1N 50Hz) 13 18 12 13 11 18 12 F7A A1 F1A A2 3 5 13 2 4 6 14 F1A 1 F7A 9 17 1 6 Page 38 1 14 6 10 HARD START CAPACITOR (IF FITTED) 1 16 15 SA205601. ELECTRIC BOX ASSY DH150AX ITEM NO. PART No. 1 9 10 11 12 13 14 15 16 17 18 DESCRIPTION SD062001 SD612053 SD158551 SD089550 SD216550 SD035352 SD271250 SD072650 SA205701 SA145801 SD035353 ELEC BOX STEEL PLATED CONTACTOR 25A 3+1 N/O AUX CAPACITOR 55µF 470V 50Hz +/-5% DELAY TIMER 7 SEC TO 9 MIN FUSE HOLDER FUSE 1/4 X 1 1/4 7A CAPACITOR 8µF TERMINAL BLOCK 6 WAY LOOM ASSY DEFROST STAT FUSE 1/4 X 1 1/4 1A SD073150 HARD START CAPACITOR (IF FITTED) QUAN UNITS 1 1 1 1 2 2 1 1 1 1 2 off off off off off off off off off off off SA205602. ELECTRIC BOX ASSY DH150AXF ITEM NO. PART No. 1 9 10 11 12 13 14 15 16 17 18 DESCRIPTION SD062001 SD612053 SD158551 SD089550 SD216550 SD035354 SD038750 SD072650 SA205701 SA145801 SD035353 ELEC BOX STEEL PLATED CONTACTOR 25A 3+1 N/O AUX CAPACITOR 55µF 470V 50Hz +/-5% DELAY TIMER 7 SEC TO 9 MIN FUSE HOLDER FUSE 10A CAPACITOR RUN CAP 15µF +/-5% 400V TERMINAL BLOCK 6 WAY LOOM ASSY DEFROST STAT FUSE 1/4 X 1 1/4 1A SD073150 HARD START CAPACITOR (IF FITTED) Page 39 QUAN UNITS 1 1 1 1 2 2 1 1 1 1 2 off off off off off off off off off off off ELECTRIC BOX ASSY DH150BX(F) (400V ~3N 50Hz) IN 3 POS'NS. 27 10 27 12 12 12 13 5 17 13 17 31 16 F1A A1 1 A2 3 5 F3A F7A L1 L2 L3 13 PHASE ROTATION RELAY F3A 14 11 1 1 6 6 R3 F1A 14 F7A 6 F3A 4 F3A 2 15 11 1 29 6 Page 40 14 SA208201 . ELECTRIC BOX ASSEMBLY DH150BX ITEM NO. PART No. 1 5 6 10 11 12 13 14 15 16 17 27 29 31 SD062001 SD614450 SD189550 SD612050 SD089550 SD216550 SD035352 SD072650 SA205801 SA145801 SD035353 SD035350 SD271250 SD403950 DESCRIPTION ELEC BOX STEEL PLATED PHASE PROTECTION RELAY RELAY C/O 2 POLE 16A 230VAC COIL CONTACTOR 9A 3+1 N/O AUX DELAY TIMER 7 SEC TO 9 MIN FUSE HOLDER FUSE 1/4 X 1 1/4 7A TERMINAL BLOCK 6 WAY LOOM ASSY DEFROST STAT FUSE 1/4 X 1 1/4 1A FUSE 3A CAPACITOR 8µF END BRACKET EW35 (8.5) QUAN UNITS 1 1 1 1 1 5 2 1 1 1 2 4 1 1 off off off off off off off off off off off off off off QUAN UNITS 1 1 1 1 1 5 2 1 1 1 2 4 1 1 off off off off off off off off off off off off off off SA208202. ELECTRIC BOX ASSY DH150BXF ITEM NO. PART No. 1 5 6 10 11 12 13 14 15 16 17 27 29 31 SD062001 SD614450 SD189550 SD612050 SD089550 SD216550 SD035354 SD072650 SA205801 SA145801 SD035353 SD035350 SD038750 SD403950 DESCRIPTION ELEC BOX STEEL PLATED PHASE PROTECTION RELAY RELAY C/O 2 POLE 16A 230vac COIL CONTACTOR 9A 3+1 N/O AUX DELAY TIMER 7 SEC TO 9 MIN FUSE HOLDER FUSE 10A TERMINAL BLOCK 6 WAY LOOM ASSY DEFROST STAT FUSE 1/4 X 1 1/4 1A FUSE 3A CAPACITOR RUN CAP 15uF+/-5% 400v END BRACKET EW35 (8.5) Page 41 ELECTRIC BOX ASSY DH150BX WHEELS AND HANDLES (400V ~3N 50Hz) IN 3 POS'NS. 10 5 28 31 12 18 F1A A1 1 A2 3 5 29 28 18 12 12 17 F7A F3A 29 L1 L2 L3 13 PHASE ROTATION RELAY F7A 14 11 F1A 14 F3A 6 F3A 4 F3A 2 16 1 6 1 R3 6 11 R2 1 R1 14 6 15 3 POS'NS. SA582501 ISS 3. ELECTRIC BOX ASSY DH150BX (WHEELS AND HANDLES) ITEM NO. PART No. 1 5 6 10 11 12 14 15 16 17 18 28 29 31 SD062001 SD614450 SD189550 SD612050 SD089550 SD216550 SD271250 SD072650 SA582601 SA145801 SD035353 SD035350 SD035352 SD403950 DESCRIPTION ELEC BOX STEEL PLATED PHASE PROTECTION RELAY RELAY C/O 2 POLE 16A 230vac COIL CONTACTOR 9A 3 + 1 N/O AUX DELAY TIMER 7 SEC TO 9 MIN FUSE HOLDER CAPACITOR 8µF TERMINAL BLOCK 6 WAY LOOM ASSY DEFROST STAT/TIMER FUSE 1/4 x 1 1/4 1A FUSE 3A FUSE 1/4 x 1 1/4 7A END BRACKET EW35 (8.5) Page 42 QUAN UNITS 1 1 3 1 1 5 1 1 1 1 2 4 2 1 off off off off off off off off off off off off off off IN 3 POS'NS. 10 5 28 31 12 18 F1A A1 1 A2 3 5 29 28 18 12 12 29 17 F7A F3A L1 L2 L3 13 PHASE ROTATION RELAY F7A 14 11 F1A 14 F3A 6 F3A 4 F3A 2 16 1 6 1 R3 6 11 R2 1 R1 14 6 15 3 POS'NS. SA582502 ISS 3. ELECTRIC BOX ASSY DH150BXF (WHEELS AND HANDLES) ITEM NO. PART No. 1 5 6 10 11 12 14 15 16 17 18 28 29 31 SD062001 SD614450 SD189550 SD612050 SD089550 SD216550 SD038750 SD072650 SA582601 SA145801 SD035353 SD035350 SD035354 SD403950 DESCRIPTION ELEC BOX STEEL PLATED PHASE PROTECTION RELAY RELAY C/O 2 POLE 16A 230V AC COIL CONTACTOR 9A 3 + 1 N/O AUX DELAY TIMER 7 SEC TO 9 MIN FUSE HOLDER CAPACITOR RUN CAP 15µF+/-5% 400V TERMINAL BLOCK 6 W AY LOOM ASSY DEFROST STAT/TIMER FUSE 1/4 x 1 1/4 1A FUSE 3A FUSE 10A END BRACKET EW 35 (8.5) Page 43 QUAN UNITS 1 1 3 1 1 5 1 1 1 1 2 4 2 1 off off off off off off off off off off off off off off ELECTRIC BOX ASSY DH300BLY(F) (400V ~3N 50Hz) 22 16 46 FAN C ONTIN UO US 28 27 FAN C YC LE 20 V IE W O N A RR O W A 48 A R RO W A L1 L2 L3 26 25 H P P U S H TO R E S ET 11 14 21 LP P U S H TO R ES E T 42 12 10 11 1 2 3 4 5 13 6 7 8 9 11 43 IN 4 PO S'NS 9 N L1 L2 L3 14 44 IN 4 PO S 'N S 18 19 17 18 12 12 IN 8 P O S 'N S Page 44 10 15 47 ASSY No SA366601 AT ISS 10 (22/06/2010). ELECTRIC BOX ASSY DH300 BLY ITEM NO. PART No. 9 10 11 12 14 15 16 17 18 19 20 21 22 25 26 27 28 42 43 44 46 47 48 SD611353 SD316550 SD611350 SD611650 SA368401 SA368301 SD089550 SD611557 SD611550 SD403750 SD080650 SA368201 SD614450 SD384550 SA062553 SD062350 SD041450 SD403550 SD403850 SD403650 SD188950 SD189050 SD023150 DESCRIPTION CONTACTOR 25A 3+1N/C AUX CIRCUIT BREAKER MINIATURE 2A CONTACTOR 9A 3P+1N/C Aux CONTACT BLK ALARM (N/O)+AUX (N/O) LOOM ASSY FAN LOOM ASSY COMP DELAY TIMER 7 SEC TO 9 MIN MOTOR STARTER O/LOAD 17.0-23.0A 3P MOTOR STARTER O/LOAD 1.6-2.5A TERMINAL BLOCK WDU4 COMPONENT BOX DRILLED LOOM ASSY INTERNAL PHASE PROTECTION RELAY LP SWITCH MANUAL RESET HP SWITCH 400psi HUMIDISTAT CONTROL KNOB TERM EARTH WPE6 8mm TERMINAL BLOCK BARRIER WAP 2.5 TERM BLOCK WDU6 ROCKER SWITCH 1 POLE C/O LABEL ROCKER SWITCH POOL THERMOSTAT 0-60 QUAN UNITS 1 1 1 2 1 1 1 1 2 8 1 1 1 1 1 1 1 1 4 4 1 1 1 off off off off off off off off off off off off off off off off off off off off off off off ASSY No SA366611 AT ISS 10 (22/06/2010). ELECTRIC BOX ASSY DH300 BLYF SPARE PARTS AS ABOVE BUT DROP AND FIT THE FOLLOWING DROP ITEM NO. PART No. 18 SD611550 DESCRIPTION MOTOR STARTER O/LOAD 1.6-2.5A QUAN 2 UNITS off FIT ITEM NO. PART No. 18 SD611551 DESCRIPTION MOTOR STARTER O/LOAD 2.5-4.0A QUAN 2 UNITS off Page 45 ELECTRIC BOX ASSY DH300BL(F) (400V ~3N 50Hz) 22 16 28 27 20 48 ARROW A L1 L2 L3 26 25 HP PUSH TO RESET 11 14 21 LP PUSH TO RESET 42 10 11 1 2 3 4 5 6 7 8 9 11 43 IN 4 POS'NS 9 N L1 L2 L3 14 44 IN 4 POS'NS 18 19 IN 6 POS'NS 17 18 12 12 46 FAN CONTINUOUS FAN CYCLE VIEW ON ARROW A Page 46 15 10 47 ASSY No SA366603 AT ISS 2 (22/06/2010). ELECTRIC BOX ASSY DH300BL ITEM NO. PART No. DESCRIPTION 9 10 11 12 14 15 16 17 18 19 20 21 22 25 26 42 43 44 46 47 48 SD611353 CONTACTOR 25A 3+1N/C AUX SD316550 CIRCUIT BREAKER MINIATURE 2A SD611350 CONTACTOR 9A 3P+1N/C Aux SD611650 CONTACT BLK ALARM (N/O)+AUX (N/O) SA368401 LOOM ASSY FAN SA368301 LOOM ASSY COMP SD089550 DELAY TIMER 7 SEC TO 9 MIN SD611557 MOTOR STARTER O/LOAD 17.0-23.0A 3P SD611550 MOTOR STARTER O/LOAD 1.6-2.5A SD403750 TERMINAL BLOCK WDU4 SA079301 HUMIDISTAT ASSY SA368203 LOOM ASSY INTERNAL SD614450 PHASE PROTECTION RELAY SD384550 LP SWITCH MANUAL RESET SA062553 HP SWITCH 400psi SD403550 TERM EARTH WPE6 8mm SD403850 TERMINAL BLOCK BARRIER WAP 2.5 SD403650 TERM BLOCK WDU6 SD188950 ROCKER SWITCH 1 POLE C/O SD189050 LABEL ROCKER SWITCH SD023150 POOL THERMOSTAT 0-60 QUAN UNITS 1 1 1 2 1 1 1 1 2 6 1 1 1 1 1 1 4 4 1 1 1 off off off off off off off off off off off off off off off off off off off off off ASSY No SA366613 AT ISS 2 (22/06/2010). ELECTRIC BOX ASSY DH300 BLF SPARE PARTS AS ABOVE BUT DROP AND FIT THE FOLLOWING DROP ITEM NO. PART No. DESCRIPTION 18 SD611550 MOTOR STARTER O/LOAD 1.6-2.5A QUAN 2 UNITS off FIT ITEM NO. PART No. DESCRIPTION 18 SD611551 MOTOR STARTER O/LOAD 2.5-4.0A QUAN 2 UNITS off Page 47 ELECTRIC BOX ASSY DH600BY/BYF (400V ~3N 50Hz) 19 16 22 21 20 43 ARROW A 38 39 11 13 15 10 12 14 IN 4 POS'NS 36 1 3 5 53 1 3 5 1 53 3 A1 5 A2 A1 A2 L1 L2 L3 1 2 3 4 5 6789 34 AUX MCB 2 N L1 L2 4 54 6 COMPRESSOR MCB 2 4 6 AUX FAN MCB CONTROL 54 4 3 5 2 4 6 PHASE 2A 2 1 ROTATION RELAY 21 N/C N/C 22 1 3 5 2 4 6 13 N/O N/O 14 14 11 6 L3 13 35 IN 6 POS'NS N L1 L2 L3 14 33 10 4 10 5 9 45 12 17 15 46 IN 10 POS'NS 41 42 FAN CONTINUOUS FAN CYCLE VIEW ON ARROW A DRAWN 1:1 Page 48 SA209901 ELECTRIC BOX ASSY DH600BY/BYF ITEM NO. PART No. 4 5 9 10 12 13 14 15 16 17 19 20 21 22 33 34 35 36 38 39 41 42 43 45 46 SD611559 SD611551 SD316550 SD611650 SD611354 SD612050 SA079801 SA079907 SD089550 SD403750 SA210301 SD080650 SD062350 SD041450 SD611550 SD403550 SD403850 SD403650 SA062553 SD062650 SD188950 SD189050 SD023150 SD614450 SD403950 DESCRIPTION MOTOR STARTER O/LOAD 20.0-25.0A 3P MOTOR STARTER O/LOAD 2.5-4.0A 3P CIRCUIT BREAKER MINIATURE 2A ALARM (N/O) + AUX (N/O) CONTACT BLK CONTACTOR 32A 3+1N/C AUX CONTACTOR 9A 3+1 N/O AUX LOOM ASSY (FAN) LOOM ASSY SCROLL COMP DELAY TIMER 7 SEC TO 9 MIN TERMINAL BLOCK W DU4 LOOM ASSY INTERNAL COMPONENT BOX ABS DRILLED HUMIDISTAT CONTROL KNOB MOTOR STARTER O/LOAD 1.6-2.5A TERM EARTH W PE6 8mm TERMINAL BLOCK BARRIER W AP 2.5 TERM BLOCK W DU6 HP SW ITCH 400psi LOW PRESSURE LTB-X325 ROCKER SW ITCH 1 POLE C/O LABEL ROCKER SW ITCH THERMOSTAT 0-60 PHASE PROTECTION RELAY END BRACKET EW 35 (8.5) Page 49 QUAN UNITS 1 1 1 2 1 1 1 1 1 10 1 1 1 1 1 1 5 4 1 1 1 1 1 1 1 off off off off off off off off off off off off off off off off off off off off off off off off off 19 83 3 Page 50 55 78 9 82 REFRIGERANT 60 4 30 24 25 14 18 23 62 33 7 27 26 17 16 6 22 21 2 15 8 20 10 32 PART DETAIL OF REAR OUTLET VERSIONS i 6 15 2 17.4 MAIN ASSEMBLIES MAIN ASSEMBLY DH150AX/BX A505201/03 MAIN ASSY DH150AX TOP/REAR OUTLET ITEM NO. PART No. 2 3 4 6 7 8 9 10 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 30 32 33 55 60 62 78 82 83 SD071750 SA205501 SA205601 SD127106 SD117950 SD287601 SD515551 SD141553 SD086951 SP066350 SD071650 SD086350 SD080650 SD149650 SD156351 SD097250 SD266450 SD266550 SD188950 SD166250 SD166550 SD062350 SD041450 SP152150 SD062150 SD208050 SD011450 SP182554 SD046650 SD023150 SD520851 SA025302 SD193950 DESCRIPTION OUTLET GRILLE CONSOLE ASSY ELEC BOX ASSY FAN ASSEMBLY (DRILLED) BRACKET DRIP TRAY COMPRESSOR PG480X3CS-4MU1 1PH 230V EVAPORATOR TEV INE-3-GA SCHRADER VALVE DUCT FLANGE SUPPORT BKT COMPONENT BOX ABS DRILLED RECEIVER/DRIER HOURS RUN METER (PANEL MOUNT) EVAP SPACER HP SWITCH ACB-DB88 400PSI LP SWITCH LCB-DA15 7 PSI ROCKER SWITCH 1 POLE C/O SOLENOID VALVE 3/8 SOLENOID COIL 230V 50HZ HUMIDISTAT CONTROL KNOB M20 PLASTIC GLAND BACK NUT ELECTRIC BOX LID OWNERS MANUAL SIDE PANEL REFRIGERANT R407c TERMINAL BLOCK COVER FOR 4 WAY POOL THERMOSTAT 0-60 SPACER MOUNTING TUBE 42mm LONG SWITCH BKT ASSY 1 PH CONDENSATE DRAIN SOCKET QUAN UNITS 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 2 2.49 1 1 3 1 1 off off off off off off off off off off off off off off off off off off off off off off off off off off off kg off off off off off A505201/03 MAIN ASSY DH150BX TOP/REAR OUTLET AS ABOVE BUT DROP AND FIT THE FOLLOWING DROP ITEM No 4 9 82 PART No SA205601 SD515551 SA025302 DESCRIPTION ELEC BOX ASSY COMPRESSOR PG480X3CS-4MU1 1PH 230V SWITCH BKT ASSY 1 PH QUAN 1 1 1 UNITS off off off FIT ITEM No 4 9 82 PART No SA208201 SD515552 SA025301 DESCRIPTION ELEC BOX ASSY COMPRESSOR YG480X3CS-9MU1 3PH 415V SWITCH BKT ASSY 3 PH QUAN 1 1 1 UNITS off off off Page 51 19 83 3 Page 52 55 78 9 82 REFRIGERANT 60 4 30 24 25 14 18 23 62 33 7 27 26 17 16 6 22 21 2 15 5 8 20 10 32 PART DETAIL OF REAR OUTLET VERSIONS i 6 15 2 MAIN ASSEMBLY DH150AX/BX(F) A505202/04 MAIN ASSEMBLY DH150AXF TOP/REAR OUTLET ITEM NO. PART No. 2 3 4 5 6 7 8 9 10 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 30 32 33 55 60 62 82 83 84 SD071750 SA205501 SA205602 SD012451 SD088851 SD117950 SD287601 SD515551 SD141553 SD086951 SP066350 SD071650 SD086350 SD080650 SD149650 SD156351 SD097250 SD266450 SD266550 SD188950 SD166250 SD166550 SD062350 SD041450 SP152150 SD062150 SD208050 SD011450 SP182554 SD046650 SD023150 SA025302 SD193950 SD520851 DESCRIPTION OUTLET GRILLE CONSOLE ASSY ELECTRIC BOX ASSEMBLY FAN ADAPTOR PLATE FAN ASSEMBLY (DRILLED) BRACKET DRIP TRAY COMPRESSOR PG480X3CS-4MU1 1PH 230V EVAPORATOR TEV INE-3-GA SCHRADER VALVE DUCT FLANGE SUPPORT BKT COMPONENT BOX ABS DRILLED RECEIVER/DRIER HOURS RUN METER (PANEL MOUNT) EVAP SPACER HP SW ITCH ACB-DB88 400PSI LP SW ITCH LCB-DA15 7 PSI ROCKER SW ITCH 1 POLE C/O SOLENOID VALVE 3/8 SOLENOID COIL 230V 50Hz HUMIDISTAT CONTROL KNOB M20 PLASTIC GLAND BACK NUT ELECTRIC BOX COVER OW NERS MANUAL SIDE PANEL REFRIGERANT R407c TERMINAL BLOCK COVER FOR 4 W AY POOL THERMOSTAT 0-60 SW ITCH BKT ASSY 1 PH CONDENSATE DRAIN SOCKET SPACER MOUNTING TUBE 42mm LONG QUAN UNITS 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 2 2.49 1 1 1 1 3 off off off off off off off off off off off off off off off off off off off off off off off off off off off off kg off off off off off A505202/04 MAIN ASSEMBLY DH150BXF TOP/REAR OUTLET AS ABOVE BUT DROP AND FIT THE FOLLOW ING DROP ITEM NO. PART No. 4 9 82 SA205602 SD515551 SA025302 FIT ITEM NO. PART No. 4 9 82 SA208202 SD515552 SA025301 DESCRIPTION ELEC BOX ASSY COMPRESSOR PG480X3CS-4MU1 1PH 230V SW ITCH BKT ASSY 1 PH 1 1 1 off off off 1 1 1 off off off DESCRIPTION ELEC BOX ASSY COMPRESSOR YG480X3CS-9MU1 3PH 415V SW ITCH BKT ASSY 3 PH Page 53 Page 54 10 13 18 28 27 56 31 82 81 22 63 61 62 21 20 37 3 OFF 0N 18 16 14 4 7 19 120 LOOM ROUTE 5 50 51 30 41 20 31 42 70 58 57 54 34 33 11 6 36 ADJUSTABLE DAMPER PLATE 2 24 99 101 60 100 FIXED IN THIS POSN WHEN DUCTING IS NOT REQD 15 32 5 17 12 8 38 9 2 25 35 F MODELS ONLY 80 46 45 i 48 49 47 44 PART DETAIL OF REAR OUTLET VERSIONS 6 DH150BX SHOP FLOOR BUILD TOP OUTLET WHEELS AND HANDLES A582401 32 2 MAIN ASSEMBLY DH150/BX(F) WHEELS AND HANDLES VERSION A582401 AT ISS 3. DH150BX SHOP BUILD WHEELS AND HANDLES ITEM NO. PART No. 1 2 3 4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 24 25 27 28 30 31 32 33 34 35 36 37 38 40 41 42 44 45 46 47 48 49 50 51 54 56 57 58 60 61 62 63 70 80 81 82 99 100 101 120 SD062150 SD071750 SA205501 SA582501 SD127106 SD515552 SD304401 SD141553 SD289750 SD289751 SD291850 SD289850 SD292250 SD288750 SD290150 SD288850 SD289550 SD520851 SD011450 SD232150 SD174151 SD294350 SD294454 SD294650 SD294750 SD086951 SP066350 SD071650 SD086350 SD080650 SD300550 SD149650 SD156351 SD097250 SD266450 SD266550 SD188950 SD085150 SD085250 SD085251 SD175750 SD175850 SD293250 SD166250 SD166550 SP152150 SD295250 SD062350 SD041450 SD293050 SD098950 SD099050 SD120550 SD117950 SD208052 SD188550 SD188450 SD295550 SD304501 SD306050 SP182554 DESCRIPTION ELEC BOX LID OUTLET GRILLE CONSOLE ASSY ELECTRIC BOX ASSY FAN ASSEMBLY (DRILLED) COMPRESSOR YG480X3CS-9MU1 3PH 415V DRIPTRAY EVAPORATOR FRAME (LEFT SIDE) FRAME (RIGHT HAND) CRASH BAR AXLE WHEEL SUPPORT BRACKET BRACKET BLANKING PANEL SADDLE WASHER SPACER MOUNTING TUBE 42mm LONG SIDE PANEL ISOLATOR SWITCH MAINS IN BOX FLOAT SWITCH (62-00-554) PERISTALTIC PUMP 11 Ltr per Hr BULKHEAD CONNECTOR LOCKING COLLET TEV INE-3-GA SCHRADER VALVE DUCT FLANGE SUPPORT BKT COMPONENT BOX ABS DRILLED PUMP BRACKET RECEIVER/DRIER HOURS RUN METER (PANEL MOUNT) EVAP SPACER HP SWITCH ACB-DB88 400PSI LP SWITCH LCB-DA15 7 PSI ROCKER SWITCH 1 POLE C/O DUCT FLANGE TOP & BOTTOM DUCT FLANGE SIDE DUCT FLANGE SIDE FILTER BRACKET FILTER BRACKET FILTER WASHABLE SOLENOID VALVE 3/8 SOLENOID COIL 230V 50HZ M20 PLASTIC GLAND BACK NUT TUBE INSERT (62-00-094) HUMIDISTAT CONTROL KNOB DAMPER PLATE TERMINAL BLOCK EARTH EK4 TERMINAL BLOCK SAK6N DIN RAIL BRACKET OWNER MANUAL M25 BUSH LOCKNUT M25 SUMP TUBE SUMP WATER FILTER REFRIGERANT R407c Page 55 QUAN UNITS 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 1 16 3 2 1 1 2 1 1 2 1 2 1 1 1 1 1 1 2 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 4 1 1 1 1 1 1 1 1 2.49 off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off kg SA582402 ISS 3 DH150BXF SHOP BUILD WHEELS AND HANDLES ITEM NO. PART No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 24 25 27 28 30 31 32 33 34 35 36 37 38 40 41 42 44 45 46 47 48 49 50 51 54 56 57 58 60 61 62 63 70 80 81 82 99 100 101 120 SD062150 SD071750 SA205501 SA582502 SD012451 SD088851 SD515552 SD304401 SD141553 SD289750 SD289751 SD291850 SD289850 SD292250 SD288750 SD290150 SD288850 SD289550 SD520851 SD011450 SD232150 SD174151 SD294350 SD294454 SD294650 SD294750 SD086951 SP066350 SD071650 SD086350 SD080650 SD300550 SD149650 SD156351 SD097250 SD266450 SD266550 SD188950 SD085150 SD085250 SD085251 SD175750 SD175850 SD293250 SD166250 SD166550 SP152150 SD295250 SD062350 SD041450 SD293050 SD098950 SD099050 SD120550 SD117950 SD208052 SD188550 SD188450 SD295550 SD304501 SD306050 SP182554 DESCRIPTION ELEC BOX LID OUTLET GRILLE CONSOLE ASSY ELECTRIC BOX ASSY FAN ADAPTOR PLATE FAN ASSEMBLY (DRILLED) COMPRESSOR YG480X3CS-9MU1 3PH 415V DRIPTRAY EVAPORATOR FRAME (LEFT SIDE) FRAME (RIGHT HAND) CRASH BAR AXLE WHEEL SUPPORT BRACKET BRACKET BLANKING PANEL SADDLE WASHER SPACER MOUNTING TUBE 42mm LONG SIDE PANEL ISOLATOR SWITCH MAINS IN BOX FLOAT SWITCH (62-00-554) PERISTALTIC PUMP 11 Ltr per Hr BULKHEAD CONNECTOR LOCKING COLLET TEV INE-3-GA SCHRADER VALVE DUCT FLANGE SUPPORT BKT COMPONENT BOX ABS DRILLED PUMP BRACKET RECEIVER/DRIER HOURS RUN METER (PANEL MOUNT) EVAP SPACER HP SWITCH ACB-DB88 400PSI LP SWITCH LCB-DA15 7 PSI ROCKER SWITCH 1 POLE C/O DUCT FLANGE TOP & BOTTOM DUCT FLANGE SIDE DUCT FLANGE SIDE FILTER BRACKET FILTER BRACKET FILTER WASHABLE SOLENOID VALVE 3/8 SOLENOID COIL 230V 50Hz M20 PLASTIC GLAND BACK NUT TUBE INSERT (62-00-094) HUMIDISTAT CONTROL KNOB DAMPER PLATE TERMINAL BLOCK EARTH EK4 TERMINAL BLOCK SAK6N DIN RAIL BRACKET OWNER MANUAL M25 BUSH LOCKNUT M25 SUMP TUBE SUMP WATER FILTER REFRIGERANT R407c Page 56 QUAN UNITS 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 1 16 3 2 1 1 2 1 1 2 1 2 1 1 1 1 1 1 2 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 2 1 4 1 1 1 1 1 1 1 1 2.49 off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off kg Page 57 11 34 32 33 41 29 47 1 3 L1 2 N L2 4 L3 5 6 7 8 9 10 11 13 12 27 12 14 22 24 (N) L1 L2 L3 11 21 HP PUSH TO RESET LP PUSH TO RESET POSITION OF TO LP SWITCH 28 AIR STAT PROBE 18 - REFRIGERANT R407c - CASTROL ICEMATIC SW68 OIL 67 89 21 SOFT START (IF FITTED) 26 77 14 12 23 22 37 31 2 TO DEFROST STAT 46 69 SOFT START (IF FITTED) 20 74 85 5 4 24 25 108 45 3 9 76 6 8 7 75 44 i MAIN ASSEMBLY DH300BLY/BLYF A363301 MAIN ASSEMBLY DH300BLY TOP OUTLET ITEM NO. PART No. 2 3 4 5 6 7 8 9 11 12 14 18 20 21 22 23 24 25 26 27 28 29 31 32 33 34 37 41 44 45 46 47 67 69 74 75 76 77 85 89 108 SD095602 SD272101 SD064060 SD064061 SD259150 SD048450 SD070360 SD363950 SA366601 SD096250 SD096450 SD023250 SD031150 SD177850 SD084550 SD070950 SD061750 SD085450 SD064950 SD066650 SD065050 SD065150 SD084350 SD075052 SD111050 SD111150 SD090150 SA205502 SD064001 SD208050 SD057553 SD070451 SP182554 SD066350 SD627050 SD048650 SD364050 SD189150 SD404253 SP148253 SD145802 DESCRIPTION EVAPORATOR MOTOR PLATE FAN FOOT LH FAN FOOT RH FAN MOTOR 0.75kW 3PH 1410RPM PULLEY 200PCDx1SPA C/IRON BELT SPA875 PB PULLEY 112 PCD ELEC BOX ASSY DRIP TRAY DRIPTRAY PLATE DRIER 3/8 SWEAT 053 SIGHT GLASS 3/8 ODS SOLDER RECEIVER (180.395.A) NRV 3/8 N.R.V. 5/8 SOLDER REV VALVE REV VALVE COIL HEAT EXCHANGER (SLHE12012009) SUCTION ACCUMULATOR PA6125-18-9C ANGLE BRACKET ANGLE BRACKET TEV SVE-8-VGA TANK CONNECTOR 22x3/4 BSPF FLEXIBLE PIPE CLEAR PVC 16mm BORE HOSE CLIP NYLON 66 SIZE 22/25 COPPER EARTH STRAP CONSOLE ASSY FAN AT12-12 OWNERS MANUAL TOP PANEL INLET GRILLE REFRIGERANT R407c SCHRADER VALVE COMPRESSOR ROTARY C-SBN453H8A SANYO TAPERLOCK BUSH 2012xDIA25 BORE TAPER LOCK BUSH 1610x19 DIA RECEIVER VERTICAL DIA130x265H CRANKCASE HEATER 35W REFRIGERATION OIL ICEMATIC SW68 DEFROST STAT/TIMER QUAN UNITS 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0.85 2 0.07 1 1 1 1 1 10 2 1 1 1 1 1 0.4 1 off off off off off off off off off off off off off off off off off off off off off off off off m off m off off off off off kg off off off off off off ls off QUAN UNITS 1 1 1 1 1 1 off off off off off off QUAN UNITS 1 1 1 1 off off off off A363311 MAIN ASSEMBLY DH300BLYF TOP OUTLET AS ABOVE BUT DROP AND FIT THE FOLLOWING DROP ITEM NO. PART No. 6 7 9 11 75 76 SD259150 SD048450 SD363950 SA366601 SD048650 SD364050 FIT ITEM NO. PART No. 6 7 9 11 SD288150 SD103650 SD087850 SA366611 DESCRIPTION FAN MOTOR 0.75kW 3PH 1410RPM PULLEY 200PCDx1SPA C/IRON PULLY 112 PCD ELECTRIC BOX ASSY TAPERLOCK BUSH 2012xDIA25 BORE TAPER LOCK BUSH 1610x19 DIA DESCRIPTION MOTOR 1.1kW 3PH 2850RPM MT80/2 PULLEY 63PCDx1SPA PULLEY 196 PCD ELECTRIC BOX ASSY Page 58 Page 59 11 34 32 33 41 29 47 N L1 L2 L3 21 12 14 22 24 (N) L1 L2 L3 11 27 LP P USH TO RE SET HP PUS H TO RESE T 28 TO LP SWITCH POSITION OF AIR STAT PROBE 21 86- CASTROL ICEMATIC SW68 OIL 67- REFRIGERANT R407c 18 69 14 12 23 SOFT START (IF FITTED) 26 31 46 2 SOFT START (IF FITTED) 20 A 74 82 37 5 4 45 3 9 76 6 8 7 75 44 i MAIN ASSEMBLY DH300BL/BLF A363303 MAIN ASSEMBLY DH300BL ITEM NO. PART No. 2 3 4 5 6 7 8 9 11 12 14 18 20 21 23 26 27 28 29 31 32 33 34 37 41 44 67 69 74 75 76 82 86 SD095602 SD272101 SD064060 SD064061 SD259150 SD048450 SD070360 SD363950 SA366603 SD096250 SD096450 SD023250 SD031150 SD177850 SD070950 SD064950 SD066650 SD065050 SD065150 SD084350 SD075052 SD111050 SD111150 SD118351 SA205502 SD064001 SP182554 SD066350 SD627050 SD048650 SD364050 SD404253 SP148253 DESCRIPTION EVAPORATOR MOTOR PLATE FAN FOOT LH FAN FOOT RH FAN MOTOR 0.75kW 3PH 1410RPM PULLEY 200PCDx1SPA C/IRON BELT SPA875 PB PULLEY 112 PCD ELEC BOX ASSY DRIP TRAY DRIPTRAY PLATE DRIER 3/8 SWEAT 053 SIGHT GLASS 3/8 ODS SOLDER RECEIVER (180.395.A) N.R.V. 5/8 SOLDER HEAT EXCHANGER (SLHE12012009) SUCTION ACCUMULATOR PA6125-18-9C ANGLE BRACKET ANGLE BRACKET TEV SVE-8-VGA TANK CONNECTOR 22x3/4 BSPF FLEXIBLE PIPE CLEAR PVC 16mm BORE HOSE CLIP NYLON 66 SIZE 22/25 THERMOSTAT PRESET CONSOLE ASSY FAN AT12-12 REFRIGERANT R407c SCHRADER VALVE COMPRESSOR ROTARY C-SBN453H8A SANYO TAPERLOCK BUSH 2012xDIA25 BORE TAPER LOCK BUSH 1610x19 DIA CRANKCASE HEATER 35W REFRIGERATION OIL ICEMATIC SW68 QUAN UNITS 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0.85 2 1 1 1 9.5 2 1 1 1 1 0.4 off off off off off off off off off off off off off off off off off off off off off m off off off off kg off off off off off ls QUAN UNITS 1 1 1 1 1 1 1 off off off off off off off QUAN UNITS 1 1 1 1 1 off off off off off A363313 MAIN ASSEMBLY DH300BLF AS ABOVE BUT DROP AND FIT THE FOLLOWING DROP ITEM NO PART No. 6 7 8 9 11 75 76 SD259150 SD048450 SD070360 SD363950 SA366603 SD048650 SD364050 FIT ITEM NO PART No. 6 7 8 9 11 SD288150 SD103650 SD070373 SD087850 SA366613 DESCRIPTION FAN MOTOR 0.75kW 3PH 1410RPM PULLEY 200PCDx1SPA C/IRON BELT SPA875 PB PULLEY 112 PCD ELEC BOX ASSY TAPERLOCK BUSH 2012xDIA25 BORE TAPER LOCK BUSH 1610x19 DIA DESCRIPTION MOTOR 1.1kW 3PH 2850RPM MT80/2 PULLEY 63PCDx1SPA BELT SPA825 PB PULLEY 196 PCD ELECTRIC BOX ASSY Page 60 4 Page 61 3 CALOREX 58 12 13 15 18 EVAP 3 121 3 4 1 2 6 5 2 1 4 3 6 5 2 1 4 3 6 5 L1 10 CAPILLARY LP SWITCH CAPILLARY HP SWITCH 2 99 98 31 1 3/8 96 7 8 115 16 14 11 6 19 28 29 32 24 97 63 58 2 1 110 104 21 1/8 1/4 1 3/8 3/4 25 26 27 1 3/8 SOLVENT CEMENT 102 SOLVENT CLEANER 120 27 1 3/8 119 7/8 1/8 1 3/8 33 20 90 1/4 35 1 3/8 TOP OUTLET VERSIONS 5/8 36 i 116 115 117 116 23 17 34 118 MAIN ASSEMBLY DH600BY/BYF TOP OUTLET A479701. MAIN ASSEMBLY DH600BY TOP OUTLET ITEM NO. PART No. 1 2 3 4 6 7 8 10 11 12 13 14 15 16 17 18 19 20 21 23 24 25 26 27 28 29 31 32 33 34 35 36 58 63 90 96 97 98 99 102 104 110 115 116 117 118 119 120 121 SD047550 SD305950 SA209901 SA205502 SD183201 SD402453 SD332752 SP066350 SA048102 SD048250 SD048351 SD048451 SD048550 SD195850 SD048850 SD070304 SD177850 SD304850 SD311050 SD049350 SD049450 SD060050 SA200701 SD070950 SP049650 SP015853 SD284250 SD047451 SD050750 SD113450 SD208050 SD459550 SD019050 SD182950 SP148253 SP182554 SD406850 SD406851 SD404254 SD406854 SD145802 SP090150 SD243450 SD203552 SD466754 SD466755 SP197253 SP197252 SD203651 DESCRIPTION QUAN UNITS DRIP TRAY STAINLESS STEEL PLATE DRIP TRAY HEATER ELEC BOX ASSY DH600BY CONSOLE ASSY FIN COIL EVAPORATOR FIN AREA813Hx1382W COMPRESSOR C-SCN903H8H OVERLOAD PROTECTOR SCHRADER VALVE FAN ASSY WITH DIA 50mm HOLE MOTOR 1.1KW 3PH 900RPM PULLEY 100 PCDx2 SPA C/IRON PULLEY 200PCDx2SPA C/IRON TAPERLOCK BUSH 1610xDIA 24 BORE TAPERLOCK BUSH 2517xDIA 25 BORE HEAT EXCHANGER BELTS SPA1120 MATCHED SET OF 2 RECEIVER (180.395.A) SUCTION ACCUMULATOR VALVE TEV SVE-15-GA DRIER 5/8 SWEAT SIGHT GLASS 5/8 ODS SOLDER REVERSING VALVE V39-321 REV VALVE COIL ASSY NRV 5/8 SOLDER FLARE BONNET FLARE NUT 1/4 BRASS N.R.V. 3/4 SOLDER INLET GRILLE OUTLET GRILLE BLANKING PLATE MANUAL DH150/300/600 VERMICULITE LOOSE INSULATION FLAT BACK NUT 1 1/2 BSP ADAPTOR 42Fx42F MULTI FIT PLASTIC REFRIGERATION OIL ICEMATICSW68 REFRIGERANT R407c VIBRATION ELIMINATOR 3/4 S/STEEL VIBRATION ELIMINATOR 1 3/8 S/STEEL SUMP HEATER 85W VIBRATION ELIMINATOR 7/8 S/STEEL DEFROST STAT COPPER EARTH STRAP PVC-U GREY PIPE 1.5in DIA ELBOW 1.5in x 1.5in 90 DEG (PVC-U) 1.5in BSPM TANK CONNECTOR (PVC-U) SOCKET PLAIN-1.5in BPSF U-PVC PVC-U SOLVENT CEMENT MEK SOLVENT/CLEANER 1.5in x 1.5in PLAIN SOCKET (PVC-U) 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5 6 1 1 1 1 1 3.5 1 1 1.7 14 1 1 2 1 1 0.1 0.78 2 1 1 0.001 0.001 1 off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off kg off off ls kg off off off off off m m off off off ls ls off A479703 MAIN ASSEMBLY DH600BYF TOP OUTLET BUILD AS ABOVE BUT DROP AND FIT THE FOLLOWING DROP ITEM NO. PART No. 12 SD048250 18 SD070304 DESCRIPTION MOTOR 1.1KW 3PH 900RPM BELTS SPA1120 MATCHED SET OF 2 QUAN 1 1 UNITS off off FIT ITEM NO. PART No. 12 SD093550 18 SD070306 DESCRIPTION MOTOR 1.5KW 3PH 1420RPM (MT90/L4) BELTS SPA1220 MATCHED SET OF 2 QUAN 1 1 UNITS off off Page 62 Page 63 4 58 12 13 15 18 FAULT MAINS STANDBY CALOREX RUN DEFROST N L1 N 3 L2 L1 L2 L3 L3 1 2 3 4 5 6 78 9 11 13 15 10 12 14 2 1 4 3 6 5 2 1 4 3 6 5 2 1 4 3 6 5 2A L2 12 14 22 24 N L1 L1 L2 L3 11 21 L3 LP SWITCH CAPILLARY HP SWITCH CAPILLARY 10 99 2 96 7 1 3/8 98 31 8 115 FOR REAR OUTLET VERSIONS NOTE:PIPE ARRANGEMENT 16 14 11 FOR REAR OUTLET VERSION 6 19 28 29 32 24 97 63 58 2 1 110 104 21 1/8 1/4 1 3/8 3/4 25 26 27 1 3/8 SOLVENT CEMENT 102 SOLVENT CLEANER 27 1 3/8 119 7/8 1/8 1 3/8 34 20 90 1/4 35 1 3/8 120 36 5/8 i 116 115 117 116 23 17 33 118 MAIN ASSEMBLY DH600BY/BYF REAR OUTLET A479702. MAIN ASSEMBLY DH600BY REAR OUTLET ITEM NO. PART No. 1 2 3 4 6 7 8 10 11 12 13 14 15 16 17 18 19 20 21 23 24 25 26 27 28 29 31 32 33 34 35 36 58 63 90 96 97 98 99 102 104 110 115 116 117 118 119 120 SD047550 SD305950 SA209901 SA205502 SD183201 SD402453 SD223752 SP066350 SA048102 SD048250 SD048351 SD048451 SD048550 SD195850 SD048850 SD070302 SD177850 SD304850 SD311050 SD049350 SD049450 SD060050 SA200701 SD070950 SP049650 SP015853 SD284250 SD047451 SD050750 SD113450 SD208050 SD459550 SD019050 SD182950 SP148253 SP182554 SD406850 SD406851 SD404254 SD406854 SD145802 SP090150 SD243450 SD203552 SD466754 SD466755 SP197253 SP197252 DESCRIPTION QUAN UNITS DRIP TRAY STAINLESS STEEL PLATE DRIP TRAY HEATER ELEC BOX ASSY DH600BY CONSOLE ASSY FIN COIL EVAPORATOR FIN AREA813Hx1382W COMPRESSOR C-SCN903H8H OVERLOAD PROTECTOR SCHRADER VALVE FAN ASSY WITH DIA 50mm HOLE MOTOR 1.1KW 3PH 900RPM PULLEY 100 PCDx2 SPA C/IRON PULLEY 200PCDx2SPA C/IRON TAPERLOCK BUSH 1610xDIA 24 BORE TAPERLOCK BUSH 2517xDIA 25 BORE HEAT EXCHANGER BELT SPA1250 (MATCHED SET OF 2) RECEIVER (180.395.A) SUCTION ACCUMULATOR VALVE TEV SVE-15-GA DRIER 5/8 SWEAT SIGHT GLASS 5/8 ODS SOLDER REVERSING VALVE V39-321 REV VALVE COIL ASSY NRV 5/8 SOLDER FLARE BONNET FLARE NUT 1/4 BRASS N.R.V. 3/4 SOLDER INLET GRILLE OUTLET GRILLE BLANKING PLATE MANUAL DH150/300/600 VERMICULITE, LOOSE INSULATION FLAT BACK NUT 1 1/2 BSP ADAPTOR 42Fx42F MULTI FIT PLASTIC REFRIGERATION OIL ICEMATICSW68 REFRIGERANT R407c VIBRATION ELIMINATOR 3/4 S/STEEL VIBRATION ELIMINATOR 1 3/8 S/STEEL SUMP HEATER 85W VIBRATION ELIMINATOR 7/8 S/STEEL DEFROST STAT COPPER EARTH STRAP PVC-U GREY PIPE 1.5in DIA ELBOW 1.5in x 1.5in 90 DEG (PVC-U) 1.5in BSPM TANK CONNECTOR (PVC-U) SOCKET PLAIN-1.5in BPSF U-PVC PVC-U SOLVENT CEMENT MEK SOLVENT/CLEANER 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5 6 1 1 1 1 1 3.5kg 1 1 1.7 14 1 1 2 1 1 0.1 0.78 2 1 1 0.001 0.001 off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off off ls kg off off off off off m m off off off ls ls A479704. MAIN ASSEMBLY DH600BY REAR OUTLET BUILD AS ABOVE BUT DROP AND FIT THE FOLLOWING DROP ITEM NO. 12 18 FIT ITEM NO. PART No. SD048250 SD070302 DESCRIPTION MOTOR 1.1KW 3PH 900RPM BELT SPA1250 (MATCHED SET OF 2) QUAN 1 1 UNITS off off PART No. DESCRIPTION QUAN UNITS Page 64 SIDE PANEL OPTIONS FOR DH150 TOP BOX ASSEMBLY SD276250 BLANKING PLATE 1 PER UNUSED FACE SD283901 DEFLECTION GRILLE 1 PER FACE MAX 3 PER ASSY SD275301 12" DUCT SPIGOT 1 PER FACE MAX 3 PER ASSY SD275303 8" DUCT SPIGOT 1 PER FACE MAX 3 PER ASSY SD275305 16" DUCT SPIGOT 1 PER FACE MAX 3 PER ASSY Page 65 SIDE PANEL OPTIONS FOR DH600 TOP BOX ASSEMBLY SD276251 BLANKING PLATE 1 PER UNUSED FACE SD283902 DEFLECTION GRILLE 1 PER FACE MAX 4 PER ASSY SD275302 12" DUCT SPIGOT 1 PER FACE MAX 4 PER ASSY SD275304 8" DUCT SPIGOT 1 PER FACE MAX 4 PER ASSY Page 66 OFF Page 67 FIG.2 60 12 20 61 67 68 N L1 31 EARTH STUD 5 3 4 1 2 5 6 6 NO 4 5 NC 13 T1 97 95 6 8 T2 T3 96 14 30 SET OVERLOAD TO 3.3 OR 4.1 FOR 'F' VERSIONS OF M/C 2 98 6 NO 3 4 NO 2 NO 1 NO 13 14 14 2 36 15 SET THERMOSTAT TO REQUIRED AIR TEMPERATURE 13 50.00 SET TO MINIMUM MO JU 11 10 ON 9 1 4 3 17.5 HEATER BOXES MAIN ASSEMBLY DH150A HEATED TOP BOX E OB PR A276004. HEATER BOX ASSY DH150A ITEM NO. PART No. 1 2 3 4 5 6 8 9 10 11 12 13 14 15 20 30 31 36 60 61 67 68 SD318901 SD276253 SD253650 SP090150 SD612052 SD612050 SD612453 SD232152 SD098950 SD198450 SD051950 SD103250 SD089550 SD253954 SD126150 SP098755 SP098757 SD023150 SD035350 SD126251 SD196550 SD051250 DESCRIPTION QUAN UNITS HEATER CONTROL BOX COVER 3kW HEATER ELEMENT COPPER EARTH STRAP CONTACTOR 18A 3+1N/O AUX CONTACTOR 9A 3+1 N/O AUX CONTACTOR O/LOAD 2.5 - 4.0 A SWITCH ROTARY 3POLE ON/OFF 63A TERMINAL BLOCK EARTH EK4 TERMINAL BLOCK SAK10 TERMINAL BLOCK SAKS3 THERMAL CUT OUT 60 DEG DELAY TIMER 7 SEC TO 9 MIN CALIBRATED THERMOSTAT (YELLOW) TERMINAL BLOCK SAKS5 TERMINAL BLOCK 2 WAY (6A) TERMINAL BLOCK 1 WAY 6A POOL THERMOSTAT 0-60 FUSE 3A FUSE 50A ELEC COMP PARTITION MELAMINE TERMINAL BLOCK END BRACKET 1 1 3 0.002 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 off off off m off off off off off off off off off off off off off off off off off off Page 68 (SOPAC JAEGER) (2) (1) TECASA HIGH LIMIT STAT 1 BL 0,5 REQUIRED AIR TEMP THERMOSTAT 2 1 1 3 2 4 CONTACTOR 5 6 4 3 B 2,5 B 2,5 B 2,5 W/R 0,5 OF DH MACHINE ( ADJACENT TO DISPLAY CONSOLE) BUTT CONNECTORS WERE SLIDE ON & PIGGY BACK DRAWING CHANGE DH 17:05:07 28:08:07 JAC APPD C/N GSM GSM DATE 4:9:97 19:12:03 2:8:04 GSM 19:7:05 DH 949 908 1053 NOTE AT CONTROL FUSE CLARIFIED 6 1167 1167/1 4 FAN CHANGE INTERCONTROL WIRING ADDED CALOREX HEAT PUMPS LTD U.C.C. C R FROM M/C FAN CAP FINISH O/LOAD 2 TO FAN BL 1,0 R P 1,0 BL B 6 WAY TERM BLOCK LOCATED IN DH M/C ELECTRIC BOX 6 5 4 3 2 1 BR FAN BR 1,0 HOLES TO BS 4500 E12 INSPECTION LEVEL DIMS GR/B 0,5 R/O 0,5 BROWN YELLOW WHITE ORANGE RED GREEN WIRING FOR 'F' VERSION FAN FIG 1 NOT REQD HEATER HOOD TO DH150 M/C SINGLE PHASE --- CONT' GM DRAWN APPD DATE 13:1:93 DRG No. D319052 1 SHT No NTS SCALE R 0,5 WHITE P 1.0 BROWN BL 1.0 G/Y 1,5 ORANGE BLACK FAN BLUE BLACK GREEN/YELLOW 6 WAY TERM BLOCK LOCATED IN DH M/C ELECTRIC BOX 6 5 4 3 2 1 ALL SHARP EDGES AND BURRS TO BE REMOVED CONDENSATE PUMP FUSE INSTRUCTION LABEL WIRING R R BL 1,0 P 1,0 WIRE FROM CONTROL FUSE BR C DISCONNECT THESE WIRES FROM 6 WAY TERM BLOCK DISCONNECT THIS END OF FAN CAP B 1,0 2 WAY T.B. BR 1,0 BR 1,0 L LP SWITCH LOCATED INSIDE DH M/C TERM, LEAVE R/O WIRE CONNECTED B 1,0 TERM BLOCK TITLE V 0,5 DISCONNECT THIS WIRE FROM 'C' BUTT CONNECTOR ON/OFF SWITCH DH MACHINE CONSOLE W/BL 0,5 CONTROL FUSE BL 1,0 BR 1,0 TOLERANCE UNLESS SPECIFIED FAN CONNECTIONS PRE DCR 1053 MATERIAL TERM BLOCK NEW 2 WAY TO B1,0 IN TO FAN O/LOAD 6 G/Y 1,5 B 4,0 R 4,0 R 4,0 G 1,0 G 1,0 BR 1,0 GR/B 0,5 P 1,0 3 SA088852 (S+P) 5 SWITCH TERM' No'S CORRECTED TECASA NOTE ADDED POINT, AT REAR OF MACHINE ABOVE EVAPORATOR. 3. ROUTE PROBE FROM HOOD (AIR TEMP STAT) TO AIR SAMPLING 2. CONNECT WIRES AS SHOWN ABOVE R 4,0 R 4,0 BL/W 0,5 BL 1,0 R 1,0 0 1,0 GR/B 0,5 P 1,0 1 R 1,0 FAN MOTOR F VERSION FAN WITH CONNECTIONS ADDED. A1 W/R 0,5 AUX CONTACTOR 6 5 R 1,0 2 O 1,0 R 1,0 FAN CAP ISS R 2,5 R 2,5 A2 1 2 3 DISCONNECT THIS WIRE FROM ON/OFF SWITCH TERM No 1 R 0,5 3 B 1,0 R 2,5 A1 A2 95 96 1. ROUTE LOOM CABLE FROM HEATER HOOD THROUGH HOLE IN SIDE NOTES AIR HEATERS R/B 0,5 G 1,0 DRG No. D319052 R 0,5 7 W 0,5 W 0,5 G/Y 1,5 OR 4.1 FOR DH150 'F' N L1 IF IN DOUBT ASK TO FAN O/LOAD 6 TO FAN O/LOAD 2 8 OTTER TEMP STAT W 0,5 SWITCH 2 4 6 P DELAY TIMER R 1,0 G 1,0 SET OVERLOAD TO 3.3 FOR DH150 1 3 5 ISOLATOR G/Y 1,5 3A 50A B 0,5 BUTT CONNECTOR SUPPLY VIA FUSED ISOLATOR. SEE MANUAL HEATED TURNING HOOD BR 1,0 3rd ANGLE PROJECTION BR 2,5 G 1,0 Page 69 SEE FIG 1 FOR 'F' VERSION D319053 ISS 8 DO NOT SCALE PRINT DH150A HEATER BOX INSTRUCTIONS ON OFF Page 70 FIG.2 60 12 12 61 67 68 N L1 L2 31 L3 EARTH STUD 5 2 1 3 6 4 5 6 3 4 5 T1 NO 97 T2 13 6 T3 NC 96 14 8 95 6 30 4.1 FOR 'F' VERSIONS OF M/C SET OVERLOAD TO 3.3 OR 2 98 4 NO 2 NO 1 NO 14 13 NO 14 SET TO MINIMUM 2 MO JU 11 10 9 1 36 SET THERMOSTAT TO REQUIRED AIR TEMPERATURE 15 13 4 3 IN 2 POSITIONS MAIN ASSEMBLY DH150B HEATED TOP BOX E OB PR 50.00 A267003. HEATER BOX DH150B ITEM NO. PART No. 1 2 3 4 5 6 8 9 10 11 12 13 14 15 30 31 36 60 61 67 68 SD318901 SD276253 SD253650 SP090150 SD612052 SD612050 SD612453 SD232150 SD051850 SD099050 SD051950 SD103250 SD089550 SD253954 SP098755 SP098757 SD023150 SD035350 SD035355 SD196550 SD051250 DESCRIPTION HEATER CONTROL BOX COVER 3kW HEATER ELEMENT COPPER EARTH STRAP CONTACTOR 18A 3+1N/O AUX CONTACTOR 9A 3+1 N/O AUX CONTACTOR O/LOAD 2.5 - 4.0 A ISOLATOR SWITCH TERMINAL BLOCK EARTH EK2.5N TERMINAL BLOCK SAK6N TERMINAL BLOCK SAKS3 THERMAL CUT OUT 60 DEG DELAY TIMER 7 SEC TO 9 MIN THERMOSTAT CALIBRATED (YELLOW) TERMINAL BLOCK 2 WAY (6A) TERMINAL BLOCK 1 WAY 6A POOL THERMOSTAT 0-60 FUSE 3A FUSE 1/4x1 1/4 16A ELEC COMP PARTITION MELAMINE TERMINAL BLOCK END BRACKET Page 71 QUAN UNITS 1 1 3 0.2 1 1 1 1 1 1 4 1 1 1 1 1 1 1 1 1 1 off off off m off off off off off off off off off off off off off off off off off B 2,5 OTTER TEMP STAT W 0,5 W 0,5 HIGH LIMIT STAT (SOPAC JAEGER) (2) (1) 2 1 3 2 4 CONTACTOR 5 6 4 1 P 2,5 BL 2,5 P 2,5 P 2,5 BL/W 0,5 BL 1,0 R 1,0 OF DH MACHINE ( ADJACENT TO DISPLAY CONSOLE) BUTT CONNECTORS WERE SLIDE ON & PIGGY BACK DRAWING CHANGE 17:05:07 JAC APPD 949 C/N GSM GSM DATE 4:9:97 22:12:03 30:7:04 GSM 19:7:05 DH 28:08:07 CALOREX HEAT PUMPS LTD U.C.C. C R FINISH MATERIAL O/LOAD 2 6 WAY TERM BLOCK LOCATED IN DH M/C ELECTRIC BOX 6 HOLES TO BS 4500 E12 INSPECTION LEVEL DIMS TOLERANCE UNLESS SPECIFIED WIRING HEATER HOOD TO DH150 M/C 3 PHASE INSTRUCTION LABEL TITLE BR R R BL 1,0 --- CONT' RED GREEN WHITE NOT REQD GM DRAWN APPD 13:1:93 DATE WIRING FOR 'F' VERSION FAN FIG 1 BLACK BLUE R 0,5 P 1.0 NTS SCALE BL 1.0 G/Y 1,5 CRIMP TOGETHER GREEN/YELLOW YELLOW FAN BLACK ORANGE BROWN YELLOW WHITE ORANGE 6 WAY TERM BLOCK LOCATED IN DH M/C ELECTRIC BOX 6 5 4 3 2 1 DRG No. D319050 1 SHT No FUSE BR 1,0 TERM BLOCK 5 FAN GR/B 0,5 R/O 0,5 DISCONNECT THESE WIRES FROM 6 WAY TERM BLOCK P 1,0 WIRE FROM CONTROL FUSE DISCONNECT THIS END OF CONTROL FUSE FAN CAP BL 1,0 2 WAY T.B. BR 1,0 B 1,0 CONDENSATE PUMP BL B BR C TERM, LEAVE R/O WIRE CONNECTED W/BL 0,5 4 3 2 1 FAN CONNECTIONS PRE DCR 1053 TO FAN FAN CAP FROM M/C BL 1,0 TERM BLOCK NEW 2 WAY TO B1,0 IN R P 1,0 BR 1,0 L DISCONNECT THIS WIRE FROM 'C' V 0,5 LP SWITCH LOCATED INSIDE DH M/C SA088852 (S+P) 1053 908 1167 DH TO FAN O/LOAD 6 BR 1,0 BL 1,0 BUTT CONNECTOR ON/OFF SWITCH DH MACHINE CONSOLE FAN MOTOR F VERSION 5 SWITCH TERM' No CORRECTED 6 NOTE AT CONTROL FUSE CLARIFIED 7 INTERCONTROL WIRING ADDED 1167/1 POINT, AT REAR OF MACHINE ABOVE EVAPORATOR. 3. ROUTE PROBE FROM HOOD (AIR TEMP STAT) TO AIR SAMPLING 2. CONNECT WIRES AS SHOWN ABOVE G/Y 1,5 BL 2,5 R 2,5 R 2,5 R 2,5 G 1,0 G 1,0 BR 1,0 GR/B 0,5 P 1,0 3 FAN CAP FAN WITH CONNECTIONS ADDED. REQUIRED AIR TEMP THERMOSTAT 3 0 1,0 GR/B 0,5 P 1,0 1 R 1,0 R 0,5 3 W/R 0,5 AUX CONTACTOR 5 6 R 1,0 OR 4.1 FOR DH150 'F' 2 O 1,0 R 1,0 DISCONNECT THIS WIRE FROM ON/OFF SWITCH TERM No 1 DRG No. D319050 R 0,5 ISS A1 A2 A1 A2 W/R 0,5 1. ROUTE LOOM CABLE FROM HEATER HOOD THROUGH HOLE IN SIDE R 2,5 W 2,5 B 2,5 B 1,0 1 2 3 IF IN DOUBT ASK TO FAN O/LOAD 6 TO FAN O/LOAD 2 4 FAN CHANGE BL 0,5 NOTES AIR HEATERS R/B 0,5 G/Y 1,5 W 0,5 G 1,0 TECASA 1 P DELAY TIMER 8 TECASA NOTE ADDED B 2,5 95 96 5 3 1 N 3A 16A 16A 16A R 1,0 G 1,0 SET OVERLOAD TO 3.3 FOR DH150 ISOLATOR SWITCH 2 4 6 N L3 L2 L1 N G/Y 1,5 SUPPLY VIA FUSED SEE ISOLATOR. MANUAL B 0,5 BUTT CONNECTOR BR 2,5 G 1,0 HEATED TURNING HOOD BR 1,0 Page 72 SEE FIG 1 FOR 'F' VERSION D64319051 ISS 8 DO NOT SCALE PRINT DH150B THREE PHASE HEATER BOX INSTRUCTIONS 17.6 LPHW KIT L.P.H.W. ASSEMBLY DH150 4 3 4 1 SA199801 LPHW ASSY ITEM NO. PART No. DESCRIPTION 1 3 4 SD195550 BOX ASSY SD170601 LPHW FIN AREA 508Hx534Wx3 ROWS SD284450 1/8 BSPM BLEED VALVE (PEGLER) Page 73 QUAN UNITS 1 1 2 off off off 17.7 DUCTING EVAP DUCT FLANGE KIT DH150 DO NOT SCALE PRINT DRG No. 3rd ANGLE PROJECTION D085650 D085650 ITEM PART No. DESCRIPTION QUAN UNITS 001 SD085150/51 DUCT FLANGE TOP & BOTTOM 2.00 off 002 SD085251 DUCT FLANGE SIDE 1.00 off 003 D087650 SEALING STRIP BLK FOAM 12x4 2000.00 mm 004 SD085250 DUCT FLANGE SIDE 1.00 off 005 P012350 RIVET POP 4 x 8.5 LNG 12.00 off 006 P025850 RIVET POP 4.8 x 12.7 LNG 10.00 off ASSEMBLE ITEMS 1,2 AND 4 TOGETHER USING ITEM 5 POP RIVETS. REMOVE PLUGS FROM CABINET SIDES, ENSURE GASKET ITEM 3 IS PLACED BETWEEN DUCT ITEM 1 (TOP AND BOTTOM) AND CABINET. THEN FIX DUCT FLANGE INTO POSITION USING ITEM 6 RIVETS. 3 4 2 6 NOTE POSN OF NOTCH OUT. 1 5 5 SH 2, 3 NOW ON CAD 949 JAC 4 SH 2, 3 NOTE 5 ADDED 357 22:9:87 3 ITEM 4 ADDED 334 27:4:87 2 NOTE ADDED 1 AS DRAWN 19:2:85 4:10:84 ISS C/N APPD IF IN DOUBT ASK 17:9:97 DATE ALL SHARP EDGES AND BURRS TO BE REMOVED INSPECTION LEVEL DIMS TOLERANCE UNLESS SPECIFIED TITLE DUCT FLANGE ASSEMBLY INSTRUCTIONS MATERIAL HOLES TO BS 4500 E12 FINISH DRAWING CHANGE C U.C.C CALOREX HEAT PUMPS LTD R DRAWN CHECKED GSM APPD DATE SCALE DRG No. D085650 Page 74 SHT No 1 CONT' 2 EVAP DUCT FLANGE KIT DH300 DO NOT SCALE PRINT 3rd ANGLE PROJECTION DRG No. D085651 D085651 ITEM PART No. DESCRIPTION QUAN UNITS 001 D187351 DUCT FLANGE TOP 1.00 off 002 D187451 DUCT FLANGE BOTTOM 1.00 off 003 D187750 DUCT FLANGE SIDE L/H 1.00 off 004 D187751 DUCT FLANGE SIDE R/H 1.00 off 005 P012350 RIVET POP 4 x 8.5 LNG 8.00 off 1. ASSEMBLE ITEMS 1,2,3 AND 4 USING ITEM 5 POP RIVETS SUPPLIED. 2. REMOVE PLASTIC CAPS AND SCREWS FROM CABINET INLET GRILLE (DO NOT REMOVE GRILLE). 3. POSITION DUCT FLANGE OVER INLET GRILLE AND RELOCATE WITH EXISTING SCREWS THROUGH DUCT AND GRILLE HOLES TO CABINET. 4. REPLACE PLASTIC CAPS. 5. VARIHEAT/DEHUMIDIFIER MACHINES - AIR SAMPLING TUPE TO BE FITTED TO CUSTOMER DUCTING, SEE BELOW. IN 8 POSITIONS 3 1 CUSTOMERS DUCTING 5 4 2 SMALL RETURN AIR SAMPLING TUBE TO BE EXTENDED ON DUCT BOTTOM IF IN DOUBT ASK ALL SHARP EDGES AND BURRS TO BE REMOVED TITLE ISS 949 JAC 16:09:97 C/N APPD DATE DUCT FLANGE ASSEMBLY INSTRUCTIONS MATERIAL INSPECTION LEVEL DIMS TOLERANCE UNLESS SPECIFIED HOLES TO BS 4500 E12 FINISH DRAWING CHANGE R C DRAWN CHECKED APPD DATE JAC 17:09:97 SCALE NTS DRG No. D085651 CALOREX HEAT PUMPS LTD U.C.C Page 75 SHT No 2 CONT' 3 A3 EVAP DUCT FLANGE KIT DH600 DO NOT SCALE PRINT 3rd ANGLE PROJECTION DRG No. D085652 PART ITEM No. DESCRIPTION QUAN UNITS 001 002 003 004 005 006 CENTRE BRACKET DUCT FLANGE TOP DUCT FLANGE BOTTOM DUCT FLANGE SIDE L/H DUCT FLANGE SIDE R/H RIVET POP 4 x 8.5 LNG 1.00 1.00 1.00 1.00 1.00 12.00 off off off off off off D187550 D187350 D187450 D187250 D187251 P012350 D085652 1. ASSEMBLE ITEMS 1,2,3,4 AND 5 USING ITEM 6 POP RIVETS SUPPLIED. 2. REMOVE PLASTIC CAPS AND SCREWS FROM CABINET INLET GRILLE (DO NOT REMOVE GRILLE). 3. POSITION DUCT FLANGE OVER INLET GRILLE AND RELOCATE WITH EXISTING SCREWS THROUGH DUCT AND GRILLE HOLES TO CABINET. 4. REPLACE PLASTIC CAPS. 5. VARIHEAT/DEHUMIDIFIER MACHINES - AIR SAMPLING TUPE TO BE FITTED TO CUSTOMER DUCTING, SEE BELOW. IN 12 POSITIONS 2 1 CUSTOMERS DUCTING 6 4 3 5 AIR SAMPLING TUBE TO BE EXTENDED AND FITTED INTO CUSTOMERS DUCTING, SEE NOTE 5. SMALL RETURN ON DUCT BOTTOM IF IN DOUBT ASK ALL SHARP EDGES AND INSPECTION BURRS TO BE REMOVED LEVEL TITLE ISS 949 JAC 19:09:97 C/N APPD DATE MATERIAL DUCT FLANGE ASSEMBLY INSTRUTIONS DIMS TOLERANCE UNLESS SPECIFIED HOLES TO BS 4500 E12 FINISH DRAWING CHANGE R C U.C.C CALOREX HEAT PUMPS LTD DRAWN CHECKED APPD DATE JAC 17:09:97 SCALE NTS DRG No. D085652 Page 76 SHT No 3 CONT' FILTER SPARES DH150 FILTER FITTING INSTRUCTIONS ITEM PART No. DESCRIPTION QUAN UNITS 001 SD175750 FILTER BRACKET 1.00 off 002 SD085251 DUCT FLANGE SIDE 1.00 off 003 D087650 SEALING STRIP BLK FOAM 12x4 1320.00 mm 004 SD085250 DUCT FLANGE SIDE 1.00 off 005 P012350 RIVET POP 4 x 8.5 LNG 12.00 off 006 P025850 RIVET POP 4.8 x 12.7 LNG 10.00 off 007 SD175850 FILTER BRACKET 1.00 off 008 SD197150 FILTER 24 X 24 X 2 WITH SPARE 2.00 off ASSEMBLE ITEMS 1,2, 4 AND 7 TOGETHER USING ITEM 5 POP RIVETS. REMOVE PLUGS FROM CABINET SIDES, ENSURE GASKET ITEM 3 IS PLACED BETWEEN DUCT ITEM 1 (TOP AND BOTTOM) AND CABINET. THEN FIX DUCT FLANGE INTO POSITION USING ITEM 6 RIVETS. FIT FILTER ITEM 8. 3 1 4 2 6 8 NOTE POSN OF NOTCH OUT. 7 5 PART NUMBER FOR SPARE FILTERS SD197003 Page 77 FILTER SPARES DH300 FITLTER FITTING INSTRUCTIONS ITEM PART No. DESCRIPTION QUAN UNITS 001 D187351 DUCT FLANGE TOP 1.00 off 002 D187451 DUCT FLANGE BOTTOM 1.00 off 003 D187750 DUCT FLANGE SIDE L/H 1.00 off 004 D187751 DUCT FLANGE SIDE R/H 1.00 off 005 P012350 RIVET POP 4 x 8.5 LNG 8.00 off 006 SD197152 27" x 29" x 2" FILTER (WITH SPARE) 2.00 off 1. ASSEMBLE ITEMS 1,2,3 AND 4 USING ITEM 5 POP RIVETS SUPPLIED. 2. REMOVE PLASTIC CAPS AND SCREWS FROM CABINET INLET GRILLE (DO NOT REMOVE GRILLE). 3. POSITION DUCT FLANGE WITH FILTER OVER INLET GRILLE AND RELOCATE WITH EXISTING SCREWS THROUGH DUCT AND GRILLE HOLES TO CABINET. 4. REPLACE PLASTIC CAPS. 5. AIR SAMPLING TUPE TO BE FITTED TO CUSTOMER DUCTING, SEE BELOW. 6. FIT FILTER INTO FRAME. IN 8 POSITIONS 3 1 CUSTOMERS DUCTING 5 6 4 2 AIR SAMPLING TUBE TO BE EXTENDED AND FITTED INTO CUSTOMERS DUCTING, SEE NOTE 5. SMALL RETURN ON DUCT BOTTOM PART No FOR SPARE FILTERS SD199002 Page 78 FILTER FITTING INSTRUCTIONS 1. 2. 3. 4. 5. 6. ITEM PART No. DESCRIPTION QUAN UNITS 001 002 003 004 005 D187550 D187350 D187450 D187250 D187251 CENTRE BRACKET DUCT FLANGE TOP DUCT FLANGE BOTTOM DUCT FLANGE SIDE L/H DUCT FLANGE SIDE R/H 1.00 1.00 1.00 1.00 1.00 off off off off off 006 P012350 RIVET POP 4 x 8.5 LNG 007 SD197153 26" x 31" x 2" FILTER (WITH SPARE) 12.00 4.00 off off ASSEMBLE ITEMS 1,2,3,4 AND 5 USING ITEM 6 POP RIVETS SUPPLIED. REMOVE PLASTIC CAPS AND SCREWS FROM CABINET INLET GRILLE (DO NOT REMOVE GRILLE). POSITION DUCT FLANGE OVER INLET GRILLE AND RELOCATE WITH EXISTING SCREWS THROUGH DUCT AND GRILLE HOLES TO CABINET. REPLACE PLASTIC CAPS. VARIHEAT/DEHUMIDIFIER MACHINES - AIR SAMPLING TUBE TO BE FITTED TO CUSTOMER DUCTING, SEE BELOW. PLACE FILTERS BEHIND DUCT. IN 12 POSITIONS 2 1 CUSTOMERS DUCTING 6 4 7 5 AIR SAMPLING TUBE TO BE EXTENDED AND FITTED INTO CUSTOMERS DUCTING, SEE NOTE 5. SMALL RETURN ON DUCT BOTTOM PART No FOR SPARE FILTERS SD199102 Page 79
Similar documents
Technical Manual DH30(7)/33(7)50(7)/55(7)/60(7)
Please read these instructions carefully as they will enable you to get maximum efficiency and reliability from your new Calorex Dehumidifier
More information